1. control panel location 18 The island canopy hood controls are located in a grey panel on underside of the canopy To open the panel press on the front edge of panel and release The control panel will drop down light blower switch switch blower speed switch 19 Check the operation of the range hood M Move light switch to 1 position The light should turn on M Move blower switch to 1 position The blower should operate M Move the blower speed switch to the far left blower speed should be LOW Move blower speed to right blower speed should gradually increase until you reach HIGH speed at far right Move blower and light switches to 0 position to turn blower and light off If range hood does not operate M Check that the circuit breaker is not tripped or the house fuse blown M Disconnect power supply Check that wiring is correct Use and Care Information WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fa
2. Configurations de circuit de d charge La hotte d aspiration pour lot est configur e bouche de d charge l usine pour la d charge travers le toit ou un He conduit de 8 3 x 25 cm mur Pour une installation sans vacuation de INS 3 1 4 x 10 po l air recyclage voir en derni re page la section d charge travers le toit Hottes recyclage sans d charge l ext rieur Le conduit d vacuation n cessaire n est pas inclus On peut utiliser un conduit d vacuation rectangulaire 8 3 cm x 25 cm 3 1 4 po x 10 po ou conduit circulaire de diam tre 17 8 cm 7 po 20 3 cm 8 po ou 22 9 cm 9 po La hotte est dot e d un orifice de d charge de 8 3 cm x 25 cm 3 1 4 po x 10 po Le circuit de d charge peut d charger lair l ext rieur travers le mur ou travers le toit Pour la d charge travers le mur on doit Remarque On doit utiliser un conduit d evacuation utiliser un coude 90 rectangulaire de 8 3 x 25 cm 3 1 4 x 10 po z La longueur effective du circuit ne doit pas tre l int rieur du chache chemin e Un conduit d evacuation sup rieure la longueur indiqu e dans le rond n entrera pas dans le cache chemin e tableau ci dessous D charge travers le toit D charge horizontale travers le mur conduit de 8 3 x 25 cm bouche de 3 1 4 x 10 po d charge d charge travers le mur murale Taille des conduits Longueur
3. e Plafond de b ton utiliser les chevilles d ancrage et vis fournies e Plafond de bois utiliser des vis bois de 10 2 cm 4 po e Plafond de pl tre ou panneaux de gypse si c est possible fixer la bride de montage aux solives si les solives ne sont pas accessibles il est n cessaire d laborer une Structure de support qui sera dissimul e derri re le plafond de pl tre ou panneaux de gypse Veiller ce que le syst me de support soit solidement fix au plafond quatre vis de blocage 8 D terminer la hauteur de la hotte On doit m nager une distance libre d au moins 61 cm 24 po entre le bas de la hotte et la table de cuisson Le bas de la hotte sera situ environ 22 9 cm 9 po au dessous de la surface inf rieure du syst me de support Pour modifier la hauteur de la hotte desserrer les quatre vis de blocage du ch ssis de support Ajuster le ch ssis de support la longueur appropri e et resserrer fermement les quatre vis de blocage avant de fixer la hotte Le cas ch ant fixer le volet de r glage fermeture l int rieur de la structure de support en bas V rifier que le volet s ouvre vers l ext rieur 9 Appuyer sur la manette l avant des filtres pour lib rer les filtres retirer les filtres de la hotte conserver les filtres part 1 0 ter le couvercle de la bo te de connexion de la hotte
4. l aide d un tournevis lame plate arracher l opercule de l orifice de passage du c ble d alimentation Ne pas arracher l opercule destin un ventilateur mont distance option Installer un connecteur de conduit dans cette ouverture la vis de bridage du connecteur de conduit doit tre l int rieur de la bo te de connexion AVERTISSEMENT Danger de poids excessif Deux personnes ou plus doivent d placer et installer la hotte Le non respect de cette instruction peut causer une blessure au dos ou d autres blessures orifice pour fixation 1 1 m Desserrer les quatre vis plac es pr s de l ouverture de d charge il devrait y avoir un espace d environ 6 4 mm 1 4 po entre la t te des vis et la hotte Soulever la hotte et ins rer les vis dans les orifices d accrochage de la structure de support Serrer les vis pour qu elles soutiennent la structure de support et de la hotte Raccordement au r seau lectrique A AVERTISSEMENT X Risque de choc lectrique D brancher de la source d alimentation lectrique avant d effectuer des raccordements Connecter le conducteur de liaison la terre avec la vis verte dans la bo te de connexion Le non respect de ces instructions peut provoquer un choc lectrique ou un accident mortel 12 m Ex cution des raccordements lectriques V1 Interrompre l alimentation lectrique v Faire passer une longueur suf
5. maximale 8 3 x 25 cm 10 7 m 35 pi 3 1 4 x 10 po Rond dia 17 8 cm 7 po 12 2 m 40 pi Rond dia 20 3 cm 8 po 15 2 m 50 pi Rond dia 22 9 cm 9 po 18 3 m 60 pi Calcul de la longueur effective du syst me do z Coude de d charge 8 3 x 25 cm Sr ga MdA 3 1 4 x 10 po Pour calculer la longueur effective du syst me de d charge on doit tenir lt x 18 m 6 pi compte de la longueur quivalente de chaque composant du syst me Composant Conduit rectangulaire Conduit rond dia 17 8 cm pess 8 3 x 25 cm 3 1 4 x 10 po 7 po 20 3 cm 8 po ou A 22 9 cm 9 po 0 6 m coude 45 2 1 m 7 pi 0 8 m 2 5 pi ti Longueur maximale 10 7 m 35 pi coude a 90 1 5 m 5 pi 1 5 m 5 pi 1 coude 90 1 5m 5 pi S Section droite 2 4 m 8 pi 2 4m 8 pi 1 bouche de d charge murale 0 m 0 pi Longueur effective de conduit coude plat 90 3 7 m 12 pi S2 de 8 3 x 25 cm 3 1 4 x 10 po 4m 13 pi Note On d conseille l emploi de conduit d vacuation flexible raccord de transition 1 5 m 5 pi En cas d utilisation de conduit d vacuation rectangle rond flexible on doit tenir compte du fait que la gt longueur effective de un pied de conduit flexible correspond a 61 cm 2 pi de conduit m tallique rigide Exemple La longueur effective d un bouche de d charge 0 m 0 pi coude de conduit flexible est le double de la murale Q longueu
6. position 1 le ventilateur doit se mettre en marche V Faire tourner le s lecteur de vitesse compl tement vers la gauche le ventilateur doit fonctionner la vitesse basse Faire tourner le s lecteur de vitesse vers la droite la vitesse du ventilateur doit augmenter progressivement jusqu la vitesse maximale lorsque le bouton est tourn compl tement vers la droite Placer les commutateurs d clairage et du ventilateur la position 0 pour commander l arr t du ventilateur et l extinction de la lampe Si les composants de la hotte ne fonctionnent pas correctement V1 D terminer si le circuit d alimentation de la hotte est aliment disjoncteur ouvert ou fusible grill V D connecter la hotte du circuit d alimentation V rifier que le c blage a t correctement r alis Renseignements d utilisation et entretien AVERTISSEMENT POUR MINIMISER LE RISQUE D INCENDIE CHOC ELECTRIQUE OU DOMMAGES CORPORELS RESPECTER LES INSTRUCTIONS SUIVANTES Utiliser cet appareil uniquement dans les applications envisag es par le fabricant Pour toute question contacter le fabricant Avant d entreprendre un travail d entretien ou de nettoyage interrompre l alimentation de la hotte au niveau du tableau de disjoncteurs et verrouiller le tableau de disjoncteurs pour emp cher tout r tablissement accidentel de l alimentation du circuit Lorsqu il n est pas possible de verrouiller le table
7. r glements en vigueur C est vous qu incombe la responsabilit d une installation correcte e Demander un technicien qualifi d installer cette hotte e Respecter lors de l installation les d gagements de s paration sp cifi s sur la plaque signal tique de l appareil La plaque signal tique avec num ro de mod le et num ro de s rie est situ e l int rieur de la hotte sur la paroi arri re La hotte d aspiration devrait toujours tre install e loin des sources de courants d air comme fen tres portes et bouches de chauffage Une prise de courant lectrique reli e la terre est n cessaire Voir Alimentation lectrique Note La hotte d aspiration pour lot est configur e l usine pour la d charge travers le toit ou un mur Pour une installation sans vacuation de l air recyclage voir en derni re page la section Hottes recyclage sans d charge l ext rieur Assurer l tanch it au niveau de chaque ouverture d coup e dans le plafond ou le mur pour l installation de la hotte 2 AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE CHOC ELECTRIQUE OU BLESSURE RESPECTER LES INSTRUC TIONS SUIVANTES Tout travail d installation ou cablage lec trique doit tre r alis par une personne qualifi e dans le respect des prescriptions de tous les codes et normes applicables y compris les codes du batiment et de protec tion contre les i
8. s derri re une plaque grise sur la sur face inf rieure de la hotte Pour y acc der appuyer sur le bord avant de la plaque pour la d gager La plaque d acc s se s parera de la hotte S lecteur de d clairage du ventilateur vitesse ventilateur Interrupteur Commutateur Utilisation de la lampe MISE EN MARCHE Placer l interrupteur d clairage la position 1 EXTINCTION Placer l interrupteur la position O Utilisation du ventilateur MISE EN MARCHE Placer le commutateur du ventilateur la position 1 ARRET Placer le commutateur la position 0 R glage de la vitesse du ventilateur Le ventilateur est command par un variateur de vitesse Faire tourner le bouton de r glage vers la gauche pour REDUIRE la vitesse et vers la droite pour AUGMENTER la vitesse Fermeture du logement des organes de commande Pousser vers le haut le bord avant de la plaque d acc s La plaque d acc s s emboite sur la hotte Nettoyage Filtres Il convient de laver fr quemment les filtres Placer les filtres m talliques dans le lave vais selle ou dans une solution chaude de d ter gent Surfaces ext rieures Nettoyer la hotte avec un d tergent doux et un linge doux Ne pas utiliser un produit de nettoyage abrasif ou un tampon de laine d acier Entretien Remplacement de la lampe L clairage est assur par une lampe fluorescente de type F33 15W T8 avec
9. service ou en t l phonant notre Centre d interaction avec la client le au num ro de t l phone 1 800 422 1230 sans frais de partout aux E U ou au Canada 10 Demande d assistance ou de service LA Si vous avez besoin d assistance ou de service aux E U T l phoner au Centre d interaction avec la client le KitchenAid sans frais d interurbain au 1 800 422 1230 Nos consultants sont disponibles pour vous aider Lors de votre appel veuillez connaitre la date d achat et les num ros au com plet de mod le et de s rie de votre appareil Ces renseignements nous aideront a mieux r pondre a votre demande S Nos consultants fournissent de l assistance pour Caract ristiques et sp cifications de notre gamme compl te d appareils lectrom nagers Renseignements concernant l installation Proc d s d utilisation et d entretien Vente d accessoires et de pi ces de rechange Assistance sp cialis e aux clients langue espag nole malentendants malvoyants etc Les r f rences aux marchands compagnies de ser vice de r paration et distributeurs de pi ces de rechange locaux Les techniciens de service d sign s par KitchenAid sont form s pour ex cuter les travaux sous garantie sur les produits et pour dispenser les services n ces saires apr s l expiration de la garantie partout aux U Pour localiser la compagnie de service d sign e par KitchenAid dans votre r gion vous
10. 3 2 cm 1 1 4 po ou une scie sauteuse ou une scie chantourner d couper les ouvertures de passage du c ble d alimentation et du conduit d vacuation Voir aux pages 3 5 les sections Circuit de d charge de l air et Alimentation lectrique 4 Si l air aspir est d charg a l ext rieur installer le conduit d vacuation voir page 3 a la section Circuit de d charge de l air Au niveau de louverture de passage dans le mur ou le toit assurer l tanch it avec un compos de calfeutrage 5 a Acheminer le c ble d alimentation a travers le plafond respecter les prescriptions du Code national des installations lectriques ou de la norme ACNOR et les prescriptions des codes et r glements locaux en vigueur La longueur du c ble devra tre suffisante pour qu il soit possible de r aliser les connexions ad quates dans la bo te de connexion de la hotte Ne pas mettre le circuit sous tension avant d avoir achev l installation Assurer l tanch it avec un produit de calfeutrage au niveau de chaque ouverture Installation chemin e section sup rieure 6 m Enlever les quatre vis de la section sup rieure de la chemin e s parer les composants de la chemin e de la structure de support 7 Aligner la bride de montage avec les trous perc s dans le plafond Fixer la structure de support au plafond utiliser les organes d ancrage recommand s pour le type de plafond
11. E D t rioration de la hotte imputable accident transformation installation incorrecte m susage incendie inondation catastrophe naturelle ou utilisation de produits non approuv s par KitchenAid R parations de pi ces ou syst mes la suite de modifications non autoris es effectu es sur l appareil Co t de pi ces de rechange ou de main d uvre de r paration pour des appareils utilis s en dehors des Etats Unis ou du Canada Au Canada frais de d placement ou de transport pour les clients qui r sident dans des r gions loign es KITCHENAID ET KITCHENAID CANADA NE SONT PAS RESPONSABLES POUR LES DOMMAGES FORTUITS OU INDIRECTS Certains Etats ou certaines provinces ne permettent pas l exclusion ou la limitation des dommages fortuits ou indirects de sorte que cette exclusion ou limitation peut ne pas s appliquer dans votre cas Cette garantie vous conf re des droits juridiques sp cifiques et vous pouvez galement avoir d autres droits variables d un Etat l autre ou d une province l autre l ext rieur du Canada et des tats Unis une garantie diff rente peut s appliquer Pour des d tails communi quer avec votre marchand KitchenAid autoris Si vous avez besoin de service voir d abord la section Contr le du fonctionnement dans ce livret Apr s avoir v rifi le Contr le du fonctionnement une aide additionnelle peut tre trouv e en v rifiant la section Demande d aide ou de
12. by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors WARNING To reduce the risk of fire use only metal ductwork This unit must be grounded Tools needed measuring tape or ruler wire stripper or utility knife allen wrench set Parts needed 2 U L or C S A listed 1 2 12 5 mm conduit connectors power supply cable 1 wall or roof cap metal vent system Parts supplied 8 trim support clips mounting bracket SUpport system upper gt chimney y E trim 2 mounting template cee upper PP chimney chimney trim lower chimney lower lower ney chimney trim LA Tr caulking gun and weatherproof caulking compound flat blade screwdriver Phillips screwdriver Product dimensions Cabinet dimensions 10 7 8 7 1 16 27 6 cm 17 9 cm a 1 2 5 cm min 11 1 8 23 8 cm max upper chimney height 60 cm overall chimney lower chimney height y Le i _ gt 23 5 8 60 cm 36 hood 35 3 8 89 9 cm or overall depth 48 hood 47 1 4 120 cm overall width Venting requirements Vent system must terminate to
13. dispositif de d marrage S2 Oter les agrafes de retenue aux deux extr mit s du diffuseur de la lampe Faire coulisser le diffuseur compl tement vers la droite Abaisser ensuite l extr mit de gauche de la vitre au rebord de dessous du rebord de soutien et faire glisser la vitre vers la gauche pour l enlever P ag soutien Installer une lampe fluorescente neuve agrafe de Positionner l extr mit de droite du diffuseur sur le rebord et faire glisser le diffuseur retenue compl tement vers la droite Positionner l extr mit de gauche du diffuseur sur le rebord et faire glisser le diffuseur vers la gauche R installer les agrafes de retenue Schema de c blage Accessoires disponibles chez le revendeur VARIATEUR DE VITESSE COMMUTATEURS A CURSEUR Note Chaque ensemble de pi ces est accom te pagn des instructions appropri es TEN Ra RA HOR Barre d accrochage pour ustensiles Acier 7 inoxydable seulement efelele el g Pi ce n 4378619 longueur 38 cm 15 po E pee EN Filtres au charbon e Pi ce n 4378623 paq de 2 s 7 Ensembles pour hotte recyclage ag NOR Pi ce n 4378625 acier inoxydable l Pi ce n 4378626 blanc ES tnor Pi ce n 8171292 biscuit LAMPE FLUORESCENTE 2 NOIR Il est n cessaire de lire ces instructions eS avant d entreprendre l installation de la ze NOIRE hotte LAMPE FLUORESCENTE Sot B
14. fight the fire with your back to an exit This fan suitable for use with solid state speed controls Operation The island canopy hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the range hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen control panel location Opening the island canopy hood control panel The hood controls are located in a grey panel on the underside of the canopy To open the panel press on the front edge of panel and release The control panel will drop down blower speed switch light blower switch switch Operating the light ON Move the light switch to the 1 position OFF Move the light switch to the 0 position Operating the blower ON Move the blower switch to the 1 position OFF Move the blower switch to the 0 position Adjusting the blower speed The blower has variable speed control Move the switch to the far left for LOW speed and to the far right for HIGH speed Closing the range hood control panel Push up on the front edge of the control panel The control panel will slide up into the canopy Cleaning Filters The filters should be washed frequently Place metal filters in dishwasher or hot detergent solution to clean Exterior s
15. pouvez consulter les Pages jaunes de votre annuaire de t l phone Si vous avez besoin de pi ces de rechange Si vous avez besoin de commander des pi ces de rechange nous vous recommandons d utiliser seule ment des pi ces autoris es par l usine Ces pi ces conviendront et fonctionneront bien parce qu elles sont fabriqu es selon les m mes sp cifications pr cises utilis es pour construire chaque nouvel appareil KitchenAid Pour localiser des pi ces autoris es par l usine dans votre r gion t l phonez notre Centre d interac tion avec la client le votre Centre de service autoris le plus proche ou le service de l usine KitchenAid en composant le 1 800 442 1111 Pour plus d assistance Si vous avez besoin de plus d assistance vous pou vez crire en soumettant toute question ou prob l me KitchenAid Brand Home Appliances Customer Interaction Center C o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Veuillez indiquer dans votre correspondance un num ro de t l phone o l on peut vous joindre dans la journ e 11 Demande d assistance ou de service Avant de faire un appel pour assistance ou service d une visite de service Si vous avez encore besoin veuillez v rifier la section Contr le du fonctionnement d aide suivre les instructions ci dessous Cette v rification pourrait vous faire conomiser le co t Si vous avez besoin d assistance ou de s
16. que la position est correcte Fixer les deux sections de la chemin e sur la structure de support avec quatre vis garniture sup rieure de la chemin e trous dans la chemin e agrafes garniture inf rieure de la chemin e trous dans la chemin e garniture agrafe 15 m Couper la longueur correcte la section sup rieure de la garniture de la chemin e Veiller ne pas d former les pi ces de garniture pendant le d coupage Ins rer les agrafes dans la pi ce de garniture Positionner la pi ce de garniture en alignant les agrafes avec les trous Pousser pour engager les agrafes dans les trous 16 m Placer les filtres dans leur logement dans la hotte le bord arri re doit passer par dessus le rebord Appuyer pour ins rer compl tement chaque filtre Contr le du fonctionnement 17 Mettre le syst me sous tension emplacement des organes de commande 18 m Les organes de commande de la hotte sont plac s derri re une plaque grise sur la surface inf rieure de la hotte Pour y acc der appuyer sur le bord avant de la plaque pour la d gager La plaque d acc s se s parera de la hotte Interrupteur Commuta S lecteur de d clairage teur du vitesse ventilateur ventilateur 19 Contr ler le fonctionnement de la hotte V1 Placer l interrupteur d clairage la position 1 la lampe doit s allumer v Placer le commutateur du ventilateur la
17. the outside Do not terminate the vent system in an attic or other enclosed area Do not use 4 10 2 cm laundry type wall caps Use metal vent only Rigid metal vent is recommended Do not use plastic or metal foil vent For the most efficient and quiet operation e t is recommended that the range hood be vented vertically through the roof through 9 22 9 cm round metal ventwork e The size of the vent should be uniform e Use no more than three 90 elbows e Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used e Do Not install two elbows together The length of vent system and number of elbows should be kept to a minimum to provide efficient performance e The vent system must have a damper If roof or wall cap has a damper Do Not use damper supplied with the range hood e Use duct tape to seal all joints in the vent system e Use caulking to seal exterior wall or roof opening around the cap Determine which venting method is best for your application and follow Preparation under Installation steps on Page 5 24 5 8 62 5 cm min 23 5 8 34 3 4 88 3 cm max 10 1 4 26 cm canopy height support _ structure height 24 61 cm min bottom of canopy to cooking surface y 36 91 4 cm base cabinet height upper chimney lower chimney canopy 8 2 4 m min 9 2 7 m max ceili
18. to make electrical connections M Connect the power supply cable to hood terminal box through the U L or C S A listed conduit connector Connect the white wire of the power supply cable with the white lead in the hood using a twist on connector connect the black wire of the power supply cable with the black lead in the hood using a twist on connector M Connect the power supply green green and yellow ground wire under the green ground screw M Tighten conduit connector screws M Replace the terminal box cover Install chimney sections 13 a Connect vent to damper or hood and seal all connections with duct tape upper chimney support system frame 14 Position upper chimney section on support system frame and secure with two screws upper chimney screws Le chimney Fit lower chimney section over upper chimney section Note clip hole arrows must point toward ceiling Check for proper position Then secure upper and lower chimney sections to support system frame with four screws ZI TER J P i AN 15 Cut upper chimney trim to correct length Be careful not to bend strips while cutting Slide clips into trim Postion to align with chimney holes Push trim strips so that clips snap into holes 16 Place filters in canopy opening so rear edge is over flange Press filters up into position Check operation 17 Turn power on
19. 0 361 3032 Rive Sud Montr al 1 800 361 0950 Qu bec 1 800 463 1523 Sherbrooke 1 800 567 6966 PROVINCES DE LATLANTIQUE 1 800 565 1598 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez Veuillez indiquer dans votre correspondance un num ro de crire en soumettant toute question ou probl me au t l phone o l on peut vous joindre le jour Service des relations avec la client le KitchenAid Canada 1901 Minnesota Court Mississauga Ontario L5N 3A7 Pi ce N 4329223 4360369 R v C 2002 KitchenAid U S A 10 2002 Marque d pos e de KitchenAid U S A KitchenAid porteur de licence au Canada Imprim en Italie
20. 7 17 8 cm 8 20 3 cm Rectangular or 9 22 9 cm Round 45 elbow 7 0 feet 2 5 feet 2 1 m P 0 8 cm S 90 elbow 5 0 feet 5 0 feet 1 5 m FA 1 5 m S 90 flat elbow 12 0 feet 3 7 m ee transition to round 5 0 feet 1 5 m gt wall cap 0 0 feet 0 0 m Q 3 1 4 x 10 8 3 cm x 25 cm vent system wall cap lt 6 ft 1 8 m gt Maximum length 35 ft 10 7 m 1 90 elbow 5 ft 15m 8 ft 2 4 m straight 8 ft 2 4 m 1 wall cap 0 ft 0m Length of 3 1 4 x 10 8 3 cm x 25 cm system 13 ft 4 m Note Flexible vent is Not recommended If it is used each foot of flexible vent used is equivalent to two feet 61 cm of straight metal vent when calculating the vent system length Example A flexible elbow equals two standard elbows Electrical requirements Important Observe all governing codes and ordinances It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A 120 volt 60 Hz AC only fu
21. 8171292 biscuit Part No 4378626 white These instructions must be read before starting the canopy hood installation KitchenAid Range Hood Warranty LENGTH OF WARRANTY KitchenAid WILL PAY FOR FULL ONE YEAR WARRANTY Labor and any parts of your range hood except light bulbs and From Date of Purchase filters which are defective in materials or workmanship when this appliance is operated and maintained according to instructions attached to or furnished with this product For models with a filter 30 day limited warranty on filter For 30 days from the date of purchase when this filter is operated and maintained according to instructions attached to or furnished with the product KitchenAid will pay for replacement parts to correct defects in material and workmanship KitchenAid WILL NOT PAY FOR A Consumable parts such as light bulbs and filters B Service calls to 1 Correct the installation of the range hood 2 Instruct you how to use the range hood 3 Replace house fuses or correct house wiring Repairs when range hood is used in other than normal single family household use Pickup and delivery This product is designed to be repaired in the home E Damage to range hood caused by accident alteration improper installation misuse fire flood act of God or use of products not approved by KitchenAid Repairs to parts or systems resulting from unauthorized modifications made to the appliance G Repl
22. Dimensions des placards Circuit de d charge de lair Alimentation lectrique Les tapes de l installation Renseignements d utilisation et entretien Sch ma de c blage 9 Accessoires 10 Garantie 11 12 Demande d assistance ou de service LI N T Go Go Go Avant de commencer Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves vous et d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient ADANGER Risque possible de d c s ou de blessure grave si vous ne suivez pas imm diatement les instructions A AVERTISSEMENT Risque possible de d c s ou de blessure grave si vous ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions Important Respecter les prescriptions de tous les codes et
23. Installation Instructions and Use and Care Guide 36 91 4 cm 48 121 9 cm Island Canopy Range Hood IMPORTANT Quick Reference Table of Contents Read and save GAN these instructions 2 Before you start 3 Product dimensions 3 Cabinet dimensions IMPORTANT 3 Venting requirements Installer Leave Installation Instructions with 5 Electrical requirements the homeowner 5 7 Installation steps Homeowner Keep Installation Instructions for 8 Use and Care Information future reference 3 9 Wiring diagram Save Installation Instructions for local electrical inspector s use 9 Accessories 10 Warranty Part No 4329223 4360369 Rev C 11 12 Requesting Assistance or Service Before you start Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean DANGER You can be killed or seriously injured if you don t immediately follow instructions AWARNING You can be killed or seriously injured if you don t follow instructions All safe
24. LANC TE DE CONN MOTEUR DU nm VENTILATEUR CIRCUIT 2 D ALIMENTATION 120 V CA a 60 Hz Note Si cette hotte d aspiration est associ e un ventilateur install distance la demande de courant ne doit pas tre sup rieure 4 amp res Garantie Garantie de la hotte d aspiration KitchenAid DUR E DE LA P RIODE DE GARANTIE KitchenAid PAIERA GARANTIE COMPL TE DE UN AN Pi ces et main d uvre sauf lampes et filtres pour A compter de la date d achat l limination d un vice de mat riau ou de fabrication lorsque cet appareil est utilis et entretenu conform ment aux instructions jointes ou fournies avec ce produit Pour les mod les avec filtre une garantie limit e de 30 jours s applique sur le filtre Pendant 30 jours compter de la date d achat lorsque ce filtre est utilis et entretenu conform ment aux instructions jointes ou fournies avec ce produit KitchenAid paiera les pi ces de rechange pour corriger des vices de mat riau ou de fabrication KitchenAid NE PAIERA PAS A Pi ces consomptibles comme lampes et filtres B Appels de service pour 1 Rectifier l installation de la hotte 2 Formation de l utilisateur 3 Remplacement des fusibles ou rectification du c blage lectrique du domicile C R parations imputables l utilisation de la hotte autrement qu en service unifamilial normal D Transport du produit Ce produit est con u pour tre r par sur place
25. SA Standards and local codes and ordinances There must be enough power supply cable from the fused disconnect or circuit breaker box the to make the connections in the hood s terminal box Do Not turn on power until installation is completed Use caulking to seal all openings Installation screw screws q q q q q Q upper g chimney Q Q Q Q q q screw 6 a Remove the four screws on the upper chimney and disassemble chimney pieces from support frame 7 Align support mounting bracket with holes in ceiling Attach support system frame to ceiling using anchors recommended for your type of ceiling Concrete ceiling use inserts and screws provided e Wood ceiling use 4 10 2 cm long wood screws e Plaster or sheet rock ceiling attach support mounting bracket to ceiling joists if possible If ceiling joists are not available you must build a supporting structure behind the plaster or sheet rock Make sure the support is connected firmly to ceiling four set screws 8 Determine the height of the canopy The range hood requires at least 24 61 cm of clearance between bottom of range hood canopy and cooking surface The bottom of the canopy will be approximately 9 22 9 cm below the bottom of the support system To change the canopy height loosen the four set screws on the support frame Adjust support frame to the desired length and tighten all
26. acement parts or repair labor costs for units operating outside the United States or Canada In Canada travel or transportation expenses for customers who reside in remote areas KITCHENAID AND KITCHENAID CANADA DO NOT ASSUME ANY RESPONSIBILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so this exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which may vary from state to state or province to province Outside the United States and Canada a different warranty may apply For details please contact your authorized KitchenAid dealer If you need service first see the Check Operation section of this book After checking the Check Operation additional help can be found by checking the Requesting Assistance or Service section or by calling our KitchenAid Customer Interaction Center 1 800 422 1230 toll free from anywhere in the U S A or Canada 10 Requesting Assistance or Service To avoid unnecessary service calls please check the Check Operation section It may save you the cost of a service call If you still need help follow the instructions below If you need assistance or service in U S A Call the KitchenAid Customer Interaction Center toll free at 1 800 422 1230 Our consultants are available to assist you When ca
27. au de disjonc teurs ou le dispositif d interruption de lali mentation placer sur le tableau de disjonc teurs une tiquette d avertissement pro mi nente interdisant le r tablissement de l ali mentation MISE EN GARDE Cet appareil est con u uniquement pour la ventilation g n rale Ne pas l utiliser pour l extraction de mati res ou vapeurs dangereuses ou explosives AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA TABLE DE CUISSON Ne jamais laisser un l ment de la table de cuisson fonctionner sans surveillance la puissance de chauffage maximale un renversement d borde ment de mati re graisseuse pourrait provoquer une inflammation et le g n ration de fum e Utiliser toujours une puissance de chauffage moyenne ou basse pour le chauffage d huile Veiller toujours faire fonctionner le ventilateur de la hotte lors d une cuisson avec une puissance de chauffage lev e ou lors de la cuisson d un mets flamber Nettoyer fr quemment les ventilateurs d extraction Veiller ne pas laisser de la graisse s accumuler sur les surfaces du ventilateur ou des filtres Utiliser toujours un ustensile de taille appropri e Utiliser toujours un ustensile de taille adapt la taille de l l ment chauffant AVERTISSEMENT POUR R DUIRE LE RISQUE DE DOMMAGES CORPORELS APRES LE DECLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINIERE APPLIQUER LES RECOMMANDATIONS SUIVANTES Placer sur le
28. awa area 800 807 6777 MANITOBA SASKATCHEWAN 800 665 1683 and 807 area code in ONTARIO QUEBEC Montreal except South Shore 800 361 3032 South Shore Montreal 800 361 0950 Quebec City 800 463 1523 Sherbrooke 800 567 6966 ATLANTIC PROVINCES 800 565 1598 For further assistance If you need further assistance you can write to Please include a daytime phone number in your KitchenAid Canada with any questions or concerns at correspondence Consumer Relations Department KitchenAid Canada 1901 Minnesota Court Mississauga Ontario L5N 3A7 Part No 4329223 4360369 Rev C Pi ce N 4329223 4360369 R v C 2002 KitchenAid 10 2002 Registered trademark trademark of KitchenAid U S A KitchenAid Canada licensee in Canada Printed in Italy Instructions d installation et Guide d utilisation et d entretien Hotte d aspiration pour cuisini re montage sur ilot 91 4 cm 36 po 121 9 cm 48 po IMPORTANT Lire et conserver ces instructions IMPORTANT Installateur Remettre les instructions d installation au propri taire de l appareil Propri taire Conserver les instructions d installation pour consultation ult rieure Conserver les instructions d installation l intention de l inspecteur local des installations lectriques Pi ce n 4329223 4360369 R v C R f rence rapide Table des mati res Pages 2 Avant de commencer Dimensions du produit
29. ccord e au r seau lectrique uniquement avec des conducteurs de cuivre La hotte doit tre raccord e directement au coupe circuit avec fusible ou au disjoncteur par l interm diaire de c ble conducteurs de cuivre blindage m tallique flexible ou gaine non m tallique Un passe fil homologation UL ou ACNOR doit tre install chaque extr mit du c ble d alimentation Le calibre des conducteurs CUIVRE SEULEMENT et les connexions Les tapes de l installation doivent tre compatibles avec la demande de courant de l appareil sp cifi e sur la plaque signal tique La taille des conducteurs doit satisfaire les prescriptions du Code national des installations lectriques ANSI NFPA 70 derni re dition ou des normes ACNOR C22 1 94 Code canadien des installations lectriques partie 1 et C22 2 N M91 derni re dition et les prescriptions de tous les codes et r glements locaux en vigueur Un connecteur de conduit homologation UL ou ACNOR doit tre install chaque extr mit du c ble d alimentation sur la hotte et sur la bo te de connexion On peut obtenir aux adresses suivantes des exemplaires des normes mentionn es National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Pr paration Du fait de la taille et du poids de cette hotte pour lot le syst
30. e garniture ae sup rieure chemin e sup rieure chemin e section inf rieure garniture inf rieure os chemin e inf rieure chemin e volet de r glage pistolet d application pour produits de calfeutrage et d tanch it ou scie chantourner tournevis lame plate ruban adh sif pour conduits tournevis Phillips Dimensions du produit Dimensions des placards 27 6 cm 17 9 cm pd 10 7 8 po 7 1 16 po l structure de support Chemin e section sup rieure hauteur de 2 5 cm 1 po min 23 8 cm 11 1 8 po max F Chemin e hauteur totale sus 62 5 cm 24 5 8 po min inf rieure 88 3 cm 34 3 4 po max 60 cm 23 5 8 po y Y Hauteur de la hotte 26 cm 10 1 4 po 7 Profondeur hors tout Largeur hors tout Distance min entre le 60 cm 23 5 8 po aa mod le 36 po 89 9 cm 35 3 8 po bas de la hotte et mod le 48 po 120 cm 47 1 4 po la table de cuisson 61 cm 24 po Circuit de d charge de lair Lz Le syst me doit d charger l air l ext rieur Ne pas terminer le conduit d vacuation au dessus d un plafond ou dans un autre espace ferm Ne pas utiliser une bouche de d charge murale de 10 2 cm 4 po normalement utilis e pour un quipement de buanderie Hauteur des Utiliser uniquement du conduit m tallique On recommande l emploi de con placards inf rieurs duit m tallique rigide Ne pas utiliser des c
31. ervice au Canada 1 Si le probl me n est pas attribuable a 2 Si vous avez besoin de service Communiquer avec la succursale ou tablissement l une des causes indiqu es dans Guide de service autoris de KitchenAid Canada le plus proche de d pannage t pour l entretien de votre appareil Voir liste ci dessous S assurer que la compagnie de service que vous contactez Communiquer avec le marchand chez qui est autoris e faire l entretien de votre appareil durant la vous avez achet votre appareil lectrom riode de garantie nager ou t l phoner KitchenAid Canada au Centre d interaction avec la client le sans frais d interurbain entre TLorsque vous demandez de l assistance ou un 8 h 30 et 18 h 00 HNE en composant 1 800 422 1230 service veuillez fournir une description d taill e du probl me les num ros complets du mod le et de s rie de l appareil et la date d achat Ces renseignements nous aideront mieux r pondre votre demande Service d appareils m nagers KitchenAid Canada Service aux consommateurs Succursales de service direct COLOMBIE BRITANNIQUE 1 800 665 6788 ALBERTA 1 800 661 6291 ONTARIO R gion d Ottawa 1 800 267 3456 l exception de l indicatif r gional 807 En dehors de la r gion d Ottawa 1 800 807 6777 MANITOBA SASKATCHEWAN 1 800 665 1683 et indicatif r gional 807 en ONTARIO QU BEC Montr al l exception de la Rive Sud 1 80
32. fisante du c ble d alimentation travers le connecteur de conduit pour pouvoir r aliser les raccordements introduire le c ble d alimentation dans la bo te de connexion travers le connecteur de conduit homologation UL ou ACNOR Raccorder ensemble avec un connecteur de fils le conducteur blanc du cable d alimentation et le conducteur blanc de la hotte raccorder ensemble avec un connecteur de fils le conducteur noir du cable d alimentation et le conducteur noir de la hotte Connecter sous la vis verte le conducteur vert ou vert et jaune du cable d alimentation utilis pour la liaison a la terre V Serrer les vis du connecteur de conduit M R installer le couvercle de la bo te de connexion Installation des sections de la chemin e 13 m Connecter le conduit d vacuation la section du volet de r glage fermeture ou la hotte assurer l tanch it de chaque jointure avec du ruban adh sif pour conduits chemin e section sup rieure structure chemin e q section sup rieure 14 Positionner la section sup rieure de la chemin e sur la structure de support fixer avec deux vis chemin e section sup rieure chemin e section inf rieure Placer la section inf rieure de la chemin e par dessus la section sup rieure Note La fl che plac e pr s de chaque trou d agrafe doit tre orient e vers le plafond V rifier
33. four set screws firmly in place before attaching canopy If used attach the vent damper to the inside bottom of the chimney support frame Make sure damper opens to outside E F 9 Press on handle in front of filters to release filters from range hood canopy Remove filters and set aside 6 1 0 Remove the terminal box cover from the range hood Remove the power supply cable knockout using a flat blade screwdriver Do not remove optional remote blower knockout Attach conduit connector into power supply cable opening so that conduit connector clamping screws are inside the terminal box WARNING Excessive Weight Hazard Use two or more people to move and install island canopy hood Failure to do so can result in back or other injury 1 1 Loosen four bolts located next to exhaust opening so that there is approximately 1 4 6 4 mm space between bolt head and canopy Lift canopy and insert bolts into slots in support system frame Tighten bolts to support system frame and canopy Electrical connection AWARNING 4 Electrical Shock Hazard Disconnect power before making electrical connections Connect ground wire to green ground screw in terminal box Failure to do so can result in death or electrical shock 12 m Make electrical connection M Disconnect power supply v Feed enough power supply cable through conduit connector
34. lling Please know the purchase date and the complete model and serial number of your appliance This information will help us better respond to your request MS Our consultants provide assistance with e Features and specifications on our full line of appliances e Installation information e Use and maintenance procedures e Accessory and repair parts sales e Specialized customer assistance Spanish speaking hearing impaired limited vision etc e Referrals to local dealers service companies and repair parts distributors KitchenAid designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the designated KitchenAid service company in your area you can also look in your telephone directory Yellow Pages If you need replacement parts If you need to order replacement parts we recom mend that you only use factory authorized parts These parts will fit right and work right because they are made to the same exacting specifications used to build every new KitchenAid appliance For further assistance If you need further assistance you can write to KitchenAid with any questions or concerns at KitchenAid Brand Home Appliances Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence To locate factory authorized part
35. me de support doit tre solidement fix au plafond Dans le cas d un plafond de pl tre ou de panneaux de gypse le support doit tre fix aux solives Si cela n est pas possible l installateur doit laborer une structure de support qui sera dissimul e par les panneaux du plafond On ne doit couper une solive ou un poteau de colombage que lorsque cela est absolu ment n cessaire S il est n cessaire de couper une solive ou un poteau du colom bage on doit construire une structure de support appropri e Avant d effectuer le d coupage v rifier que les distances de s paration appropri es seront respect es autour du conduit d vacua tion dans le plafond ou la cavit du mur 1 Placer un pais mat riau de protection sur le plan de travail la table de cuisson ou la cuisini re pour la protection contre la poussi re et les dommages ventuels Choisir une surface plane pour l assemblage de l appareil Recouvrir cette surface d un mat riau de protection appropri avant d y placer tous les composants de la hotte et les accessoires 2 Sur le plafond marquer la ligne qui correspondra a l axe central de la hotte apr s son installation 3 m Avec le gabarit de montage marquer sur le plafond la position des trous de la bride de montage louverture d couper pour le passage du conduit d vacuation le cas ch ant et louverture de passage du c ble d alimentation Avec une m che de
36. ncendies Le fonction nement de cet appareil peut modifier la cir culation de l air et affecter le fonction nement d un appareil utilisant un com bustible Respecter les directives du fabri cant de l quipement de chauffage et les prescriptions des normes de s curit comme celles publi es par la National Fire Protection Association NFPA et American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE et les prescriptions des autorit s r glementaires locales Lors d op rations de d coupage et de per age dans un mur ou plafond veiller ne pas endommager les c blages lec triques ou canalisations qui peuvent s y trouver Le conduit d vacuation associ a un venti lateur doit toujours d charger l air l ex t rieur AVERTISSEMENT Pour r duire le risque d incendie utiliser uniquement des conduits m talliques Cet appareil doit tre reli la terre perceuse niveau r gle ou m tre pince d nuder couteau utilitaire jeu de cl s Allen cisaille de ferblantier Pieces n cessaires 2 connecteurs de conduit 12 5 mm 1 2 po homologation U L ou ACNOR cable d alimentation 1 bouche de d charge pour toit ou mur conduit d vacuation m tallique Pi ces fournies 8 agrafes pour garniture bride de E support Structure de support garniture _ sup rieure CA chemin e 4 gabarit de gt montage a
37. ng to floor Venting methods This island canopy range hood is factory set for venting through the roof or wall For non vented recirculating installations see Non Vented Recirculating Kits on back page Vent system needed for installation is not included 3 1 4 x 10 8 3 cm x 25 cm rectangular 7 17 8 cm round 8 20 3 cm round or 9 22 9 cm round vent may be used The hood exhaust opening is 3 1 4 x 10 8 3 cm x 25 cm Ventwork can terminate either through the roof or wall To vent through a wall a 90 elbow is needed The vent system length should not exceed the lengths shown in the chart below Vent size Maximum length 3 1 4 x 10 35 ft 10 7 m 8 3 cm x 25 cm 7 17 8 cm round 40 ft 12 2 m 8 20 3 cm round 50 ft 15 2 m 9 22 9 cm round 60 ft 18 3 m Vertical roof venting roof cap eg 3 1 4 x 10 through the roof inside chimney cover Calculating the vent system length To calculate the length of the system you need add the equivalent feet for each vent piece used in the system 8 3 cm x 25 cm Note 3 1 4 x 10 8 3 cm x 25 cm rectangular vent must be used inside chimney cover Round vent will not fit Horizontal wall venting 3 1 4 x 10 8 3 cm x 25 cm ll through the wall see 3 1 4 x 10 8 3 cm x 25 cm elbow Vent Piece 3 1 4 x 10 8 3 cm x 25 cm
38. onduits de plastique ou de m tal 94 4 cm 36 po flexible Pour un fonctionnement efficace et silencieux e On recommande que lair soit aspir verticalement et d charg travers le toit par l interm diaire d un conduit m tallique rond de 22 9 cm 9 po e La taille du conduit d vacuation doit tre uniforme e Ne pas utiliser plus de trois coudes 90 e S il est n cessaire d installer plusieurs coudes ceux ci devront tre s par s par une section rectiligne d au moins 61 cm 24 po e Ne pas raccorder deux coudes ensemble e Pour maximiser l efficacit minimiser la longueur effective totale du syst me de d charge et le nombre de coudes e Le syst me de d charge doit comporter un volet de r glage Si la bouche de d charge sur le toit ou travers le mur comporte un volet de r glage ne pas utiliser le volet de r glage fourni avec la hotte e Au niveau de chaque jointure du syst me de d charge assurer l tanch it avec du ruban adh sif pour conduit e Autour de la bouche de d charge l ext rieur assurer l tanch it avec un produit de calfeutrage D terminer la m thode d vacuation de l air la plus appropri e pour l application et ex cuter la pr paration d crite dans les stapes de l installation la page 5 aa chemin e section sup rieure chemin e section inf rieure Distance entre plafond et plancher 240 cm 96 po min a 270 cm 108 po max
39. r cipient un couvercle bien ajust une t le biscuits ou un plateau m tallique POUR ETOUFFER LES FLAMMES puis teindre le br leur VEILLER A EVITER LES BRULURES Si les flammes ne s teignent pas imm diatement EVACUER LA PI CE ET CONTACTER LES POMPIERS NE JAMAIS PRENDRE EN MAIN UN RECIPIENT ENFLAMME le risque de br lure est lev NE PAS UTILISER D EAU ni un torchon humide ceci pourrait provoquer une explo sion de vapeur br lante Utiliser un extincteur SEULEMENT si Il s agit d un extincteur de classe ABC dont on conna t le fonctionnement Il s agit d un petit feu encore limit len droit o il s est d clar Les pompiers ont t contact s Il est possible de garder le dos orient vers une sortie pendant l op ration de lutte con tre le feu Ce ventilateur peut tre utilis avec les commandes de vitesse circuits int gr s Utilisation de la hotte La fonction de la hotte est d aspirer les fum es vapeurs de cuisson et odeurs au dessus de la table de cuisson Pour obtenir les meilleurs r sultats mettre le ventilateur de la hotte en marche avant le d but de la cuis son et laisser le ventilateur fonctionner pen dant plusieurs minutes apr s l ach vement de la cuisson pour l extraction de toute fum e et odeur de la cuisine emplacement des organes de commande Acc s aux organes de commande de la hotte Les organes de commande de la hotte sont plac
40. r effective d un coude standard Alimentation lectrique Important Respecter les prescriptions de tous les codes et r glements en vigueur C est au client qu incombe la responsabilit de e Contacter un lectricien qualifi pour l installation e Veiller ce que l installation lectrique soit r alis e d une mani re ad quate et en conformit avec les prescriptions du Code national des installations lectriques ANSI NFPA 70 derni re dition ou des normes ACNOR C22 1 94 Code canadien des installations lectriques partie 1 et C22 2 N M91 derni re dition et avec les prescriptions de tous les codes et r glements locaux en vigueur Si un conducteur distinct de liaison la terre est utilis lorsque le code le permet on recommande qu un lectricien qualifi v rifie que la liaison la terre est ad quate L appareil doit tre aliment par un circuit 120 volts 60 Hz CA seulement 15 A avec un fusible sur chaque conducteur Ne pas utiliser une tuyauterie de gaz pour la liaison la terre En cas d incertitude quant la qualit de la liaison la terre de la hotte consulter un lectricien qualifi Ne pas installer un fusible en s rie avec le conducteur neutre ou le conducteur de liaison la terre IMPORTANT Conserver les instructions d installation l intention de l inspecteur local des installations lectriques La hotte doit tre ra
41. s in your area call our Customer Interaction Center telephone number your nearest authorized service center or KitchenAid Factory Service at 1 800 442 1111 11 Requesting Assistance or Service Before calling for assistance or service please check the Check Operation section It may save you the cost of a service call If you still need help follow the instructions below If you need assistance or service in Canada 1 If the problem is not due to one of the items 2 If you need service listed in Check Operation t Contact your nearest KitchenAid Canada Appliance Service branch or authorized servicing outlet to service your appliance See list below Contact the dealer from whom you urchased your appliance or call the f P y PP Make sure the service company you contact is KitchenAid Canada Customer Interaction Center toll free authorized to service your appliance during the 8 30 a m 6 p m EST warranty period at 1 800 422 1230 tWhen asking for assistance or service please provide a detailed description of the problem your appliance s complete model and serial numbers and the purchase date This information will help us respond properly to your request KitchenAid Canada Appliance Service Consumer Services Direct service branches BRITISH COLUMBIA 800 665 6788 ALBERTA 800 661 6291 ONTARIO Ottawa area 800 267 3456 except 807 area code Outside the Ott
42. sed electrical supply is required on a separate 15 amp circuit fused on both sides of the line Do not ground to a gas pipe Check with a qualified electrician if you are not sure range hood is properly grounded Do not have a fuse in the neutral or ground circuit IMPORTANT Save Installation Instructions for electrical inspector s use The range hood must be connected with copper wire only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or nonmetallic sheathed copper cable A U L or C S A listed strain relief must be provided at each end of the power Installation steps supply cable Wire sizes COPPER WIRE ONLY and connections must conform with the rating of the appliance as specified on the model serial rating plate Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply cable at the range hood and at the junction box Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Prepara
43. sten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when cooking flaming foods Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS INTHE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFULTO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned greasy spillovers that may ignite DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it is started The fire department is being called You can
44. tion Because of the size and weight of this island canopy hood the support sys tem must be securely attached to the ceiling For plaster or sheet rock ceilings the support must be attached to joists If this is not possible you must build a support structure behind the plaster or sheet rock Do Not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Before making cutouts make sure there is proper clearance within the ceiling or wall for exhaust vent 1 Put a thick protective covering over countertop cooktop or range to protect from damage or dirt Select a flat surface for assembling the unit Cover that surface with a protective covering and place all hood parts and hardware on it 2 a Determine and mark the centerline on the ceiling where the range hood will be installed 3 a Using the mounting template mark the location of the support mounting bracket holes vent cutout if used and power supply cable cutout on the ceiling Use 1 1 4 3 2 cm drill and saber saw or keyhole saw to cut openings for power supply cable and vent See Venting requirements and Electrical requirements Pages 3 5 4 If venting to the outside install vent system See Venting requirements Page 3 Use caulking to seal exterior wall or roof openings 5 Run wiring through ceiling according to the National Electrical Code or C
45. ty messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Important Observe all governing codes and ordinances Proper installation is your responsibility e Have a qualified technician install this range hood e Comply with installation clearances specified on the model serial rating plate Model serial rating plate is located inside the range hood on the rear wall Island canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Grounded electrical outlet is required See Electrical requirements Note The island canopy hood is factory set for venting through the roof or wall For non vented recirculating installations see Non Vented Recirculating Kits on the back page All openings in ceiling and wall where range hood will be installed must be sealed WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Installation work and electrical wiring must be done by qualified person s in accordance with all applicable Codes and Standards including Fire Rated Construction The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline and safety standards such as those published
46. urfaces Clean the hood with a mild detergent and soft cloth Do Not use abrasive cleanser or steel wool pads Maintenance Replacing the light bulb This range hood uses fluorescent lamp type F33 15W T8 and starter type 52 Remove the retainer clips from both ends of the light cover Carefully slide the cover all the way to the right Then lower the left end of the glass below the support flange and remove the glass by sliding it back from the left Install a new fluorescent light bulb Position the right end of the light cover over the flange and slide the cover all the way to the right Position the left end of the light cover over the flange and slide the cover back to left Reinstall the retainer clips Wiring diagram Speed Control Slide Switches 1 8 1 a i Pa a SA j oo l ejelelele i I BLE BALLAST TRANS BLK ere FLUORESCENT LAMP En LE FLUORESCENT LANP BALLAST TRANS WHT BLOWER MOTOR LINE IN 128 UAC 6BHz WHT Note If a remote blower is used with this range hood current draw must not exceed 4 amps flange retainer clips Accessories available from your dealer Note Instructions are included with each kit Utensil Bar Part No 4378619 15 38 cm long stainless steel only Charcoal Filters Part No 4378623 2 per pkg Non Vented Recirculating Kits Part No 4378625 stainless steel Part No
Download Pdf Manuals
Related Search
Related Contents
Philips CD Soundmachine AZ100B HMK15 取扱説明書 - M210185JA-B clicando aqui Marantz PM6004B audio amplifier Copyright © All rights reserved.
Failed to retrieve file