Home

Broan-NuTone Best By Broan ILB9 Inline Blower Options: 860 CFM Kitchen Hood

image

Contents

1. MODELS ILB9 ILB11 Page 4 To clean blower assembly Remove access panel unplug blower from housing remove blower mounting nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor 29 SERVICE PARTS 97014853 99150415 98009520 97014784 97014728 99150591 97006142 99150471 98005512 99420470 98009531 93150487 98005513 99400035 97014788 99260477 99200202 97014785 99080490 99080491 93260447 98009516 99020286 98009514 99150417 98009513 97016794 Damper Flap Screw 8B x 14 16 req Duct Connector 2 req Housing Assembly Mounting Bracket 2 req Mounting Screw 4 req Wiring Harness Ground Screw 10 32 x gt 2 req Wiring Adapter Plate Access Panel Nut 4 req Movable Housing Panel Screw 10 24 x 375 8 req Outlet Box Cover Strain Relief Bushing Motor Bracket Whiz Nut 20 11 req Screw 1 4 20 x V2 5 req Blower Scroll Motor ILB9 Motor ILB11 Nut Hex Flange 5 16 18 5 req Support Bracket Blower Wheel Inlet Ring Screw 8 18 x 14 5 req Scroll Support Channel Blower Assembly Complete ILB9 Includes Key Nos 15 thru 25 Blower Assembly Complete ILB11 Includes Ke
2. A Usted sabe que tiene un extinguidor de clas ABC y lo sabe utilizar B El incendio es peque o y contenido dentro del rea donde se inici C Los bomberos han sido avisados D Usted puede combatir el incendio con una salida a su espalda Basado en las recomendaciones para Seguridad en la Cocina publicadas por la NFPA de los EEUU CUIDADO A 1 Para uso de ventilaci n general solamente No lo use para extraer materiales o vapores peligrosos o explosivos 2 Para evitar da o a los cojinetes del motor y h lices ruidosas y o desequilibradas mantenga la unidad de potencia lejos de roc os de yeso polvo de construcci n etc 3 Si el ventilador se instala en un rea sin acondicionamiento como por ejemplo en un tico Rodee el ventilador con material de aislamiento t rmico para minimizar la posible condensaci n 4 Para m s informaci n y requisitos favor leer la etiqueta de especificaciones del producto CONTENDIO Este manual consiste en las siguientes secciones INSTALACI N T PICA Esta secci n muestra una instalaci n com n en una estructura nueva y en una existente Montaje estructura nueva Montaje estructura existente Montaje el usar kit de suspender Conexiones el ctricas Colocaci n de conductos descarga derecho por del ventilador OPCIONES DE MONTAJE OPCIONES PARA LA CONEXI N EL CTRICA Colocaci n de la placa de conexiones OPCIONES PARA LA COLOCA
3. OPTIONS DE CABLAGE POSITION DE LA PLAQUE DE CABLAGE BRANCHEMENT DU CABLE D ALIMENTATION ALA VERTICALE _BRANCHEMENT DU de CABLE D ALIMENTATION A L HORIZONTALE La plaque de c blage se fixe sur le c t ou sur le dessus du bo tier OPTIONS D INSTALLATION DES CONDUITS POSITIONS DE LA D CHARGE DE LA SOUFFLERIE PANNEAU CONNECTEUR AMOVIBLE DU CONDUIT sortie CONNECTEUR DU CONDUIT sortie Le panneau tourn et panneau amovibl couvre le c t ouvert pr c dent amp PANNEAU AMOVIBLE placer ici CONNECTEUR DU CONDUIT prise Ventilateur illustr en position de d charge de soufflerie droit angle Changer la position du panneau amovible tel qu illustr INSTALLATION DES CONDUITS d charge de soufflerie droit angle CONNECTEUR DU CONDUIT prise Ventilateur illustr en position de d charge de soufflerie dans ligne Pr assembl CHAPEAU DE TOIT CONDUIT CIRCULAIRE DE 10 po 25 4 cm TRANSITIONS CIRCULAIRE DE 8 x 12 po AU 10 po 20 3 x 30 5 au 25 4 cm CONDUIT CIRCULAIRE DE 10 po 25 4 cm Raccordement de conduit typique un ventilateur converti en d charge verticale MODELS ILB9 ILB11 BY BROAN Page 12 UTI LISATI ON ET E NTR ETI E N Pour nettoyer la soufflerie Retirer la panneau d access d brancher la soufflerie du boftier retirer les crous de fixation de la soufflerie et Suivre les instructions de c blage fournies
4. SPRING HANGER KIT CHAIN 10 ROUND DUCT INTAKE f lt 8 X12 TO gt 10 ROUND lt gt TRANSITIONS gt y y GRILLE NUT i Install into 10 ROUND square holes in DUCT housing OUTLET _ HANGER KIT NUT amp WASHER MOUNTING BRACKET ACCESS PANEL SCREW Blower factory shipped in straight through discharge position DUCTING Straight through blower discharge 10 ROUND DUCT 8 X 12 TO 10 ROUND TRANSITIONS 10 ROUND ELBOW Two ways to connect ductwork to a factory shipped unit BY BROAN WIRING EDGE OF HOUSING GROUND TO WIRING PLATE WL RS 120 VAC LINE IN _ from range hood Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes MOUNTING OPTIONS 14 20 hex nuts secure mounting brackets to housing Loosen and re tighten or remove and replace nuts as necessary for desired mounting bracket position 0 0 Factory Shipped Straight Through Factory Shipped Discharge Straight Through Mounting brackets flipped over and mounted to additional framing Outlet perpendicular to joists New or Existing construction OD Mounting brackets in factory shipped position mounted directly to joists Outlet parallel to joists New construction Housing Converted to Right Angle Discharge Factory Shipped Straight Through Discharge Mounting brackets flipped o
5. Siga las instrucciones para las conexiones el ctricas que vienen empacadas con el campana y observe todos los c digos locales y estatales y el C digo El ctrico Nacional ADVERTENCIA Para reducir el riesgo de sufrir una descarga el ctrica antes de dar servicio al ventilador descon ctelo del suministro el ctrico PIEZAS DE SERVICIO MODELOS ILB9 ILB11 P gina 8 Para limpiar el conjunto del ventilador Quite el panel de acceso desconecte el ventilador del alojamiento quite las tuercas de montaje del ventilador y cuidadosamente saque el ventilador del alojamiento Use el aditamento apropiado de la aspiradora o un pa o suave y jab n o detergente suave para limpiar el rea de descarga y la rueda del ventilador NO PERMITA QUE ENTRE AGUA AL MOTOR Aseg rese de que el conjunto del ventilador est completamente seco antes de volverlo a instalar El motor est permanentemente lubricado No lubrique ni desmonte el motor 29 CLAVEN PIEZAN DESCRIPCI N 97014853 Solapa del regulador 99150415 Tornillo 8B x 14 se req 16 98009520 Conjunto del regulador se req 2 97014784 Conjunto del alojamiento 97014728 Abrazadera de montaje se req 2 99150591 Tornillo de montaje se req 4 97006142 Arn s de alambre 99150471 Tornillo de conexi n a tierra 10 32 x 12 se req 2 98005512 Placa de conexiones 99420470 Tuerca del panel de acceso se req 4 98009531 Panel de cubierta movi
6. compra original NO HAY OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante este per odo de un a o Broan reparar o cambiar a su opci n y sin cobro cualquier producto o pieza que se encuentre defectuosa bajo uso y servicio normal ESTA GARANTIA NO SE EXTIENDE A ARRANCADORES DE LAMPARAS FLUORESCENTES Y TUBOS Esta garant a no cubre a mantenimiento y servicio normales o b cualquier producto o pieza que hayan sido sometidos a uso equivocado negligencia accidente mantenimiento o reparaci n indebida excepto por Broan instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n La duraci n de cualquier garant a impl cita se limita a un per odo de un a o seg n se especifica en la garant a expl cita Algunos estados no permiten limitaci n a la duraci n de una garant a impl cita por lo que esta limitaci n tal vez no se aplica al caso suyo A LA OBLIGACION DE BROAN DE REPARAR O CAMBIAR A OPCION DE BROAN SERA EL UNICO Y EXCLUSIVO REMEDIO AL COMPRADOR BAJO ESTA GARANTIA BROAN NO SERA RESPONSABLE POR DA OS NCIDENTALES CONSECUENTES O ESPECIALES QUE SURJAN DE O EN RELACIONA EL USO O DESEMPENO DEL PRODUCTO Algunos estados no permiten la exlusi n o limitaci n de da os incidentales o consecuent es por lo que esta limitaci n o exclusi n tal vez no se aplica en su caso Esta garant a le da derechos lega
7. n est pas possible mettez bien en vue un signal d avertissement telle qu une tiquette sur le panneau d alimentation 3 L installation et la pose des fils lectriques doivent tre effectu es par une ou des personnes qualifi es conform ment tous les codes et normes applicables incluant les normes de construction en rapport aux incendies 4 ll faut suffisamment d air pour une combustion appropri e et l chappement des gaz par le tuyau de la chemin e de l quipement br lant du combustible pour pr venir un contre courant Suivez les instructions du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et des autorit s du code local 5 Lors de la coupe ou du per age dans un mur ou un plafond prenez soin de ne pas endommager les fils lectriques et les autres utilit s dissimul es 6 La d charge des ventilateurs conduit par l vent doit toujours se faire l ext rieur 7 Pour r duire le rsque d incendie utilisez seulement des donduits de ventila tion en m tal 8 Si cette unit doit tre install e au dessus d une baignoire ou d une douche elle doit tre marqu e comme tant appropri e pour l application et tre connect e un circuit d riv prot ge GFCI interrupteur de circuit en cas de d faut de mise la terre du neu
8. so the above limitation may not apply to you BROAN S OBLIGATION TO REPAIR OR REPLACE AT BROAN S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan at the address or phone number stated below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Best by Broan P O Box 140 Hartford WI 53027 1 800 637 1453 99043703B BY BROAN VENTILADORES PARA MONTAJE EN L NEA MODELOS ILB9 ILB11 P gina 5 LEA Y CONSERVE ESTAS INSTRUCCIONES A PARA COCINAR EN CASA SOLAMENTE A ADVERTENCIA A PARA REDUCIR EL RIESGO DE INCENDIO GOLPE EL CTRICO O LESI N A PERSONAS OBSERVE LO SIGUIENTE 1 Use esta unidad solamente de la manera indicada por el fabricante Si tiene preguntas p ngase en contacto con el fabricante a la direcci n o tel fono que apa
9. AIRE DE NS N2227777777 Ni COUDE CIRCULAIRE DE 10 po 25 4 cm Deux mani res de raccorder les conduits un appareil pr mont BY BROAN CABLAGE DESSUS ARRIERE DU BOITIER FIL DE TERRE A PLAQUE DE CABLAGE PLAQUE DE Al CABLAGE ENTREE 120 VCA du le hotte Le ventilateur peut tre branch depuis l ext rieur du bo tier Utiliser des connecteurs homologu s UL pour les branchements conform ment aux codes locaux en vigueur OPTIONS DE MONTAGE Des crous a six pans 4 20 fixent les supports au bo tier Desserrer et resserrer ou retirer et replacer les crous si n cessaire selon la position d sir e pour le support LI D charge de soufflerie dans ligne pr sassembl e D charge de soufflerie dans k 45 7 om l Supports retourn s et fix s un cadre suppl mentaire Sortie perpendiculaire aux Supports en position pr assembl e Sortie parall le aux solives B timent en cours de con solives struction Construction neuve ou existante Boitier converti en d charge de soufflerie droit de soufflerie dans ligne pr sassembl e Supports retourn s et fix s en haut du bo tier Bo tier suspendu par des c bles Sortie parall le aux solives Construction neuve ou existante Supports retourn s et fix s un cadre suppl mentaire Sortie droit angle Construction neuve ou existante MODELS ILB9 ILB11 Page 11
10. BY BROAN IN LINE BLOWERS I MODELS ILB9 ILB11 lt M N N ii TT f Page 1 READ AND SAVE THESE INSTRUCTIONS A FOR DOMESTIC COOKING ONLY A WARNING A TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR IN JURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service discon necting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a quali fied person s in accordance with all applicable codes and stan dards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Con ditioning Engineers ASHRAE
11. CI N DE CONDUCTOS Posiciones de la descarga del ventilador Colocaci n de conductos descarga ngulo recto del ventilador USO Y CUIDADO PIEZAS DE SERVICIO GARANT A Instalador Deje este manual con el due o de casa Due o de casa Informaci n del uso y mantenimiento en la p gina 8 LOA BY BROAN INSTALACION TIPICA MONTAJE Estructura nueva CONDUCTO REDONDA DE TRANSICIONES DE 10 25 4 cm salida 8 X12 A 10 REDONDA 20 3 x 30 5 cm a 25 4 cm redonda CONDUCTO REDONDA DE 10 25 4 cm Ventilador entrada enviado de f brica en x del ventilador TUERCA DE ABRAZA PARILLA Instale en 8 X MONTAJE los agujeros cuadros en la VIGUETA DEL cubierta TECHO centros de 24 61 cm TORNILLO DE PANEL DE PANEL DE ACCE ACCESO PGES Unidad enviada de f brica instalada en una estructura nueva MONTAJE Estructura existente TRANSICI NES DE 8 X 12 A CONDUCTO 10 REDONDA 20 3 x 30 5 cm REDONDA DE 10 a 25 4 cm redonda 25 4 cm entrada CONDUCTO REDONDA DE 10 25 4 cm salida Ventilador enviado de f brica en posici n de descarga ngulo recto del ventilador TORNILLOS DE ABRAZA Ss DERAS DE YA o MONTAJE LE VIGUETA DEL SN TUERCA TECHO ack centros PANEL DE S PARILLA K Instale en ROCESS los agujeros cuadros en TORNILLO DE PANEL DE ACCESO la cubierta Unidad enviada de f bri
12. CTRICAS PARTE SUPERIOR POSTERIOR DEL ALOJAMIENTO TIERRAA LA PLACA DE CONEXIONES PLACA DE CONEXIONES BLANCO A BLANCO L NEA DE ENTRADA DE KT 120 VCA de la campana El ventilador se puede conectar desde el exterior del alojamiento Use conectores aprobados por UL en la conexi n en cumplimiento con los c digos locales OPCIONES DE MONTAJE Las tuercas hexagonales de 1 4 x 20 aseguran las abrazaderas de montaje en el alojamiento Afloje y vuelva a apretar o quite y reemplace las tuercas seg n sea necesario para colocar las abrazaderas de montaje en la posici n deseada LT F brica descarga derecha por del ventilador N F brica po descarga derecha 38 1 a por del ventilador 63 5 mm le 18 45 7 cm Abrazaderas de montaje volteadas y montadas a la 22 55 9 cm Abrazaderas de montaje en la posici n ajustada en f brica armaz n addicional La salida queda paralela a las La salida queda perpendicular a viguetas las viguetas Estructura nueva Estructura nueva o existente lt Cubierta convertido a descarga ngulo recto del F brica ventilador descarga derecha L pro del ventilador leo 55 9 cm Abrazaderas de montaje volteadas y montadas a la tapa de la cubierta Cubierta asegurada con los cables La salida queda paralela a las viguetas Estructura nueva o existente Le 18 45 7 cm l Abrazaderas de monta
13. D CARE e SERVICE PARTS e WARRANTY Installer Leave this manual with the homeowner Homeowner Use and Care information on page 4 LOA BY BROAN TYPICAL INSTALLATION MOUNTING New Frame Construction 10 ROUND DUCT ee OUTLET 8 X 12 TO 10 ROUND a TRANSITIONS 10 ROUND DUCT INTAKE GRILLE NUT Install into square holes in housing S g Ventilator factory shipped in straight through discharge position MOUNTING BRACKETS CEILING JOIST 24 centers shown ACCESS PANEL ACCESS PANEL SCREW Factory shipped unit installed in new construction MOUNTING Existing Frame Construction 10 ROUND DUCT INTAKE 8 X 12 TO 10 ROUND TRANSITIONS D 10 ROUND DUCT MOUNTING SCREWS GRILLE NUT CEILING Install into JOIST square 24 g holes in centers housing shown w Ventilator factory shipped Td ACCESS in straight through discharge position PANEL SCREW ACCESS PANEL Factory shipped unit installed in existing construction IMPORTANT Remove shipping tape from damper Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight MODELS ILB9 ILB11 Page 2 TYPICAL INSTALLATION MOUNTING USING HANGER KIT included lt lt HANGER i E KIT BOLT amp WASHER EXTENSION
14. ILB4 93260447 Ecrou hexagonal collerette 5 16 18 5 oblig 98009516 Support 99020286 Roue de soufflerie inclut n l gende 22 98009514 Bague d arriv e 99150417 Vis 8 18 x 1 4 5 oblig 98009513 Support de volute 97016796 Soufflerie ensemble ILB9 inclut n l gende 15 26 97016797 Soufflerie ensemble ILB4 inclut n l gende 15 26 98009532 Panneau de access 99150472 Vis de fixation de panneau de access 4 oblig 97016791 Kit de accrocher T463 Transition de 8 x 12 po au 10 po circulaire 20 3 x 30 5 cm au 25 4 cm circulaire 97014597 Kit de plaque de ventilateur Commander les pi ces de rechange par num ro de r f rence et non l aide du num ro de l gende Visserie standard peut tre achet e localement ENSEMBLE DE Non montr assembl SOUFFLERIE GARANTIE 2 29 J O O1 B ND GARANTIE LIMIT E D UN AN DE BROAN Broan garantit l acheteur consommateur original de ses produits qu ils sont exempts de d fauts dans les mati res premi res ou la main d oeuvre pour une p riode d un an compter de la date d achat original IL N Y A a GARANTIES EXPRIMEES OU IMPLICITES INCLUANT MAIS NON PAS LIMITE AUX GARANTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE DANS UN BUT PARTI Pendant cette p riode d un an Broan son choix r parera ou remplacera gratuitement tout produit ou pi ce qui s av re d fectueu
15. and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities Ducted fans must always be vented to the outdoors To reduce the risk of fire use only metal ductwork If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Never place a switch where it can be reached from a tub or shower 10 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings B Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Pepper corn Beef Flambe C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOW ING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burn
16. avec le hotte et respecter retirer d licatement la soufflerie du boitier Utiliser un accessoire tous les codes locaux et provinciaux en vigueur de m me que le Code d aspirateur appropri ou retirer la grille et nettoyer l aide d un chiffon national de l lectricit doux et de savon ou de d tergent doux pour nettoyer la zone de d charge de la soufflerie et la roue NE PAS LAISSER D EAU AVERTISSEMENT Pour diminuer les risques de d charge S INFILTRER DANS LE MOTEUR S assurer que la soufflerie est lectrique d brancher la source d alimentation avant toute compl tement s che avant de la r installer op ration d entretien Le moteur est lubrifi en permanence Ne pas lubrifier ou d monter le moteur PIECES DE RECHANGE LEGENDE N DEREF DESCRIPTION 97014853 Clapet 99150415 Vis 8B x 1 4 16 oblig 98009520 Registre 2 oblig 97014784 Bo tier 97014728 Support 2 oblig 99150591 Vis 10 16 x 7 8 4 oblig 97006142 Harnais a fils 99150471 Vis de terre 10 32 x Y2 2 oblig 98005512 Plaque de c blage 99420470 Ecrou de panneau d access 4 oblig 98009531 Panneau amovible du boitier 93150487 Vis 1410 24 x 375 8 oblig 98005513 Couvercle de la boite de c blage 99400035 R ducteur de tension 97014788 Support de moteur 99260477 Ecrou Y4 20 11 oblig 99200202 Vis 4 20 x Y2 5 oblig 97014785 Volute 99080490 Moteur ILB9 99080491 Moteur
17. ble 93150487 Tornillo 10 24 x 375 se req 8 98005513 Cubierta de la caja de conexiones 99400035 Buje de alivio de tensi n 97014788 Abrazadera del motor 99260477 Tuerca 1 4 20 se req 11 99200202 Tornillo 4 20 x Y2 5 req 97014785 Conjunto del caracol 99080490 Motor ILB9 99080491 Motor ILB4 93260447 Tuerca Hex Flange 5 16 18 se req 5 98009516 Abrazadera del soporte 99020286 Rueda del ventilador Incluye clave N 22 98009514 Anillo de entrada 99150417 Tornillo 8 18 x 14 se req 5 98009513 Abrazadera de soporte del caracol 97016796 Conjunto del ventilador completo ILB9 Incluye art clave N 15 26 Conjunto del ventilador completo ILB 11 Incluye art clave N 15 26 Panel de acceso Tornillo del panel de acceso se req 4 Kit de suspender Transici n 20 3 x 30 5 a 25 4 cm redondo 8 x 12 a 10 po redondo Kit de placa del ventilador o JO O1 D 97016797 98009532 99150472 97016791 T463 97014597 Pida las piezas de repuesto por N DE PIEZA no por N DE CLAVE Herraje est ndar se puede comprar localmente No mostrado ensamblado GARANTIA CONJUNTO DEL VENTILADOR GARANTIA LIMITADA DE BROAN DE UN A O Broan le garantiza al consumidor comprador original de sus productos que tales productos estar n libres de defectos en materiales o mano de obra por un per odo de un a o a partir de la fecha de
18. ca instalada en una estructura existente IMPORTANTE Quite la cinta del env o de apagador Aseg rese de quitar la cinta que fija la pesta a del regulador du rante la transportaci n y de que esta pesta a abra y cierre libremente dentro del conducto Utilice cinta de conductos para asegurar y hermetizar las conexiones de los conductos MODELOS ILB9 ILB11 P gina 6 INSTALACI N T PICA MONTAJE EL USAR KIT DE SUSPENDER incluido TORNILLO Y lt A ARANDELA DE KIT DE SUSPENDER RESORTE EXTENCI N CADENA DE CONDUCTO KIT DE REDONDA DE 10 SUSPENDER 25 4 cm entrada TORNILLO DE OJO DE KIT DE TRANSICI NES DE8 X12 A 10 REDONDA lt 4 N TUERCA Y 20 3 x 30 5 cm ARANDELA a 25 4 cm S e DEKIT DE redonda SUSPENDER ABRAZADERAS DE MONTAJE D TUERCA DE 1 T PARILLA Instale CONDUCTO 7 en los agujeros REDONDA DE 10 gt cuadros en la 25 4 cm salida cubierta PANEL DE ACCESO i TORNILLO DE PANEL i DE ACCESO Ventilador enviado de f brica en posici n de descarga derecha por del ventilador COLOCACI N DE CONDUCTOS descarga derecho por del ventilador __ VENTILACI N EN EL ALERO CONDUCTO DE be o tease 10 25 4 cm 20 3 X 30 5 cm A salida REDONDO DE 10 25 4 cm CONDUCTO DE J CODO REDONDO DE 10 25 4 cm 10 25 4 cm entrada Dos formas de conectar los conductos a una unidad enviada de f brica BY BROAN CONEXIONES ELE
19. ecta para dicha aplicaci n y debe conectarse a un protegido GFCI Cortacicuito Accidental a Tierra 9 Nunca instale un interruptor donde se pueda alcanzar desde una ba era o ducha 10 Esta unidad se debe conectar a tierra PARA REDUCIR EL RIESGO DE INCENDIO DEBIDO AGRASA ACUMULADA EN LAS HORNILLAS 1 Nunca deje sin atender las unidades de superficie cuando tengan ajustes altos Los reboses pueden provocar humo y derrames grasosos que se pueden incendiar Caliente lentamente el aceite en un ajuste bajo o medio 2 Siempre ENCIENDA la campana cuando cocine con alta temperatura o cuando cocine alimentos que se puedan incendiar 3 Limpie con frecuencia los ventiladores No debe permitir que la grasa se acumule en el ventilador ni en el filtro 4 Utilice un sart n de tama o adecuado Siempre utilice el utensilio adecuado al tama o del elemento de superficie PARA REDUCIR EL RIESGO DE LESION A PERSONAS RESULTADO DE UN INCENDIO DEBIDO AGRASA ACUMULADA EN LAS HORNILLAS PROCURE LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal despu s apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUE Y AVISEALOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS Usted se podr quemar 3 NO UTILICE AGUA incluyendo toallas de cocina mojadas puede resultar una explosi n de vapor violenta ADVERTENCIA A 4 Utilice un extinguidor SOLAMENTE si
20. ed 3 DO NOT USE WATER including wet dishcloths or towels vio lent steam explosion will result 0 Y O WARNING A 4 Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION A 1 For general ventilating use only Do not use to exhaust hazard ous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 If ventilator is installed in an unconditioned space such as an attic Surround the ventilator with thermal insulation to minimize possible condensation 4 Please read specification label on product for further informa tion and requirements TABLE OF CONTENTS This manual is divided into sections as follows e TYPICAL INSTALLATION This section shows a common installation Mounting New Frame Construction Mounting Existing Frame Construction Mounting Using Hanger Kit included Ducting straight through blower discharge Wiring e MOUNTING OPTIONS e WIRING OPTIONS Wiring Plate Position e DUCTING OPTIONS Blower Discharge Positions Ducting vertical blower discharge e USE AN
21. je volteadas y montadas a la armaz n addicional La salida ngulo recto Estructura nueva o existente MODELOS ILB9 ILB11 P gina 7 OPCIONES PARA LA CONEXI N EL CTRICA COLOCACI N DE LA PLACA DE CONEXIONES CONEXI N VERTICAL DEL CABLE DE ALIMENTACI N HORIZONTAL DEL CABLE DE ALIMENTACI N La placa de conexiones se monta a los lados o en la parte superior del alojamiento OPCIONES PARA LA COLOCACI N DE CONDUCTOS POSICIONES DE LA DESCARGA DEL VENTILADOR CONECTOR CONECTOR DEL CONDUCTO DEL CONDUCTO salida salida El alojamiento rotado y el panel movible cubre la cara abierta anterior PANEL MOVIBLE MOVIBLE cambie a esta localizaci n CONECTOR DEL CONDUCTO entrada CONECTOR DEL CONDUCTO entrada Ventilador mostrado en la posici n de ngulo recto del ventilador Cambie el panel movible a la nueva posici n seg n lo mostrado COLOCACI N DE DUCTOS Descarga ngulo recto del ventilador Ventilador mostrado en la posici n de descarga derecho por del ventilador F brica ____ VENTILACI N EN EL ALERO CONDUCTO REDONDO DE 10 25 4 cm TRANSICI NES 8 X 12 20 3 X 30 5 cm A REDONDO DE 10 25 4 cm salida CONDUCTO REDONDO DE 10 25 4 cm entrada Conexion tipica de los conductos al ventilador cambiado a posici n de descarga ngulo recto por del ventilador BY BROAN USO Y CUIDADO
22. les espec ficos y usted puede tener otros derechos que var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar para servicio bajo esta garant a usted debe a notificar a Broan en la direcci n que aparece abajo o al tel fono 1 800 637 1453 b dar el n mero de modelo y la identificaci n de pieza y c describir el defecto en el producto o pieza Al solicitar servicio bajo la garant a usted debe presentar evidencia de la fecha de compra original En los Estados Unidos llame Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 En Canada llame Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario L5T 1H9 905 670 2500 99043703B BY BROAN VENTILATEURS MONTAGE DANS LIGNE MODELES ILB9 ILB11 Page 9 LIRE ET CONSERVER CES INSTRUCTIONS A POUR USAGE DOMESTIQUE SEULEMENT A AVERTISSEMENT A POUR R DUIRE LE RISQUE D INCENDIE DE CHOC LECTRIQUE O DE BLESSURES PERSONNELLES OBSERVEZ CE QUI SUIT 1 Utilisez cette unit seulement de la fa on pr vue par le fabricant Pour d autres renseignements contactez le fabricant l adresse ou au num ro de t l phone qui se trouve dans la garantie 2 Avant d effectuer une r paration ou un entretien sur cet appareil coupez le courant au tableau d alimentation et verrouillez celui ci pour emp cher que la tension soitremise accidentellement Lorsque le verrouillage de la d connexion
23. o PANNEAU ECROU DE 25 4 cm D ACCESS GRILLE sortie Installez sur VIS DE PANNEAU les trous D ACCESS carr s dans le logement Appareil install dans un b timent d j construit IMPORTANT Retirez la bande d exp dition de amortisseur Veiller retirer le ruban adh sif d exp dition du volet du registre et s assurer que ce dernier s ouvre et se ferme librement l int rieur du conduit Utiliser du ruban adh sif pour assurer et tancher les raccords des conduits MOD LES ILB9 ILB11 Page 10 INSTALLATION TYPIQUE MONTAGE EN UTILISANT LE KIT DE CINTRE inclus VIS ET RONDELLE DE LE KIT POUR ACCROCHER RESSORT DE PROLONGATION CONDUIT CHA NE DE LE KIT POUR ACCROCHER _ BOULON D OEIL DE LE KIT POUR TRANSITION DE 8 x 12 po au 10 po circulaire 20 3 lt x 30 5 cm au 25 4 cm circulaire CONDUIT CIRCULAIRE DE 10 po 25 4 cm SORTIE PANNEAU D ACCESS CIRCULAIRE DE 10 po 25 4 cm ADMISSION A VIS ET 4 RONDELLE DE LE KIT POUR ACCROCHER SUPPORTS CROU DE o TT PANNEAU i D ACCESS Installez sur les trous carr s dans le logement VIS DE PANNEAU 17 D ACCESS Soufflerie pr assembl e en position de d charge dans ligne INSTALLATION DES CONDUITS d charge de soufflerie dans ligne TRANSITION CIRCULAIRE 8x 12 po 20 3 x 30 5 cm AU 10 po 25 4 cm CONDUIT CIRCULAIRE DE 10 po 25 4 cm CHAPEAU DE TOIT CONDUIT CIRCUL
24. ocher Installation des conduits d charge de soufflerie dans ligne C blage OPTIONS DE MONTAGE OPTIONS DE C BLAGE Position de la plaque de c blage OPTIONS D INSTALLATION DES CONDUITS Positions de la d charge de la soufflerie Installation des conduits d charge de soufflerie droit angle e UTILISATION ET ENTRETIEN PIECES DE RECHANGE GARANTIE Installateur Remetez ce manuel au protpri taire de maison Propri taire de maison Mode d utilisation et soin la page 12 BY BROAN INSTALLATION TYPIQUE MONTAGE Construction en cours CONDUIT CIRCULAIRE DE 10 po 25 4 cm sortie TRANSITION DE 8 x 12 po au 10 po circulaire 20 3 x 30 5 cm au 25 4 cm circulaire CONDUIT CIRCULAIRE DE 10 po 25 4 cm prise ECROU DE GRILLE Installez sur les trous carr s dans le logement a Soufflerie SOLIVE DE pr assembl e en PLAFOND position de d charge 24 po 61 cm de soufflerie centre dans ligne VIS DE SS PANNEAU PANNEAU D ACCESS D ACCESS Appareil install dans un b timent en cours de construction MONTAGE construction termin e CONDUIT CIRCULAIRE DE 10 po TRANSITIONS DE 8 x 12 po au 25 4 cm 10 po circulaire 20 3 x 30 5 cm au prise 25 4 cm circulaire SUPPORTS pr assembl s pour plafonds de Y po 1 27 cm d paisseur Soufflerie pr assembl e en position de d charge de soufflerie droit angle CONDUIT eae CIRCULAIRE SUPPORTS DE 10 p
25. recen en la garant a 2 Antes de limpiar o de poner en servicio la unidad apague el interruptor en el panel de servicio y asegure el panel de servicio para evitar que se encienda accidentalmente Cuando el dispositivo para desconectar el servicio el ctrico no puede ser cerrado con alg n tipo de traba sujete fuertemente al panel de servicio una etiqueta de advertencia prominente 3 Eltrabajo de instalaci n y cableado el ctrico deben estar hechos por personal capacitado de acuerdo con todos los c digos y est ndares aplicables incluyendo c digos y est ndares de construcci n a prueba de incendios 4 Se necesita suficiente aire para la combusti n y extracci n de gases por la chimenea del equipo que quema combustible para evitar la retrogresi n de las llamas Siga las directrices del fabricante y est ndares de seguridad como los publicados por la Asociaci n Nacional de Protecci n Contra Incendios o por sus siglas en ingl s NFPA y la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado o por sus sigles en ingl s ASHRAE y los c digos de las autoridades locales 5 Cuando corte o taladre en una pared o cielo raso no da e cableado el ctrico o instalaciones no visibles 6 Ventiladores con conductos siempre deben extraer hacia el exterior 7 Para reducir el riesgo de incendio use s lo ductos de metal 8 Si esta unidad va a instalarse sobre una ba era o ducha debe marc rsela como corr
26. ristar Drive Mississauga Ontario L5T 1H9 905 670 2500 99043703B
27. s linges vaisselles ou serviettes mouill s car cela peut provoquer une violente explosion de vapeur 4 Utilisez un extincteur SEULEMENT si A ll s agit d un extincteur de classe ABC et que vous savez comment vous en servir B Il s agit d un petit feu qui ne se propage pas ailleurs que sur la cuisini re C Vous avez appel votre poste local de lutte contre les incendies D Vous pouvez combattre le feu tout en ayant acc s une sortie Bas sur Kitchen Fire Safety Tips dit par NFPA ATTENTION 1 Pour ventilation g n rale seulement Ne l utilisez pas pour vacuer les vapeurs ou mat riaux dangereux ou que peuvent exploser 2 Pour viter d endommager les coussinets du moteur et des turbines bruyantes et ou mal quilibr es assurez que l unit motrice est exempte de poussi re provenant des murs en pierres s ches et la construction 3 Si le ventilateur est install dans un endroit non conditionn tel qu un grenier Entourez le ventilateur d un isolant thermique afin de r duire toute condensation ventuelle 4 Veuillez lire l tiquette de sp cifications sur le produit pour d autres renseignements et exigences TABLE DES MATI RES Ce manuel se divise comme suit INSTALLATION TYPIQUE Cette section montre une installation standard dans un b timent en cours de construction ou d j construit Montage construction en cours Montage construction termin e Montage kit pour accr
28. tre 9 Ne placez jamais un interrupteur dans un endroit o il peut tre rejoint d une baignoire ou d une douche 10 Cette unit doit tre mise la terre AFIN DE DIMINUER LES RISQUES D INCENDIE POUVANT SE D CLENCHER SUR LA SURFACE DE CUISSON 1 Ne jamais laisser sans surveillance des unit s de surface r gl es feu vif En plus de g n rer de la fum e les d bordements de graisse peuvent prendre feu Chauffer les huiles lentement feu doux ou moyen 2 Toujours mettre en marche la hotte durant la cuisson feu vif ou la cuisson d aliments flamber 3 Nettoyer r guli rement les ventilateurs d a ration On ne doit tol rer aucune accumulation de graisse sur le ventilateur ou sur le filtre 4 Utiliser une casserole de grosseur appropri e Toujours utiliser une batterie de cuisine proportionnelle l l ment de surface AFIN DE DIMINUER LES RISQUES DE BLESSURES POUVANT SURVENIR LORSQU UN FEU SE DECLENCHE SUR LA SURFACE DE CUISSON SUIVEZ CES DIRECTIVES 1 TOUFFEZ LES FLAMMES avec un couvercle herm tique une t le bis cuits ou un plateau en m tal puis teignez la cuisini re PRENEZ GARDE AUX BRULURES Si vous ne parvenez pas teindre imm diatement les flammes EVACUEZ LES LIEUX ET CONTACTEZ VOTRE POSTE LOCAL DE LUTTE CONTRE LES INCENDIES 2 NE VOUS EMPAREZ JAMAIS D UN PLAT QUI S EST ENFLAMME Vous risqueriez de vous br ler AVERTISSEMENT A 8 N UTILISEZ JAMAIS D EAU incluant le
29. ver and mounted to top of housing Housing secured with cables Outlet parallel to joists New or Existing construction Mounting brackets flipped over and mounted to additional framing Outlet vertical New or Existing construction MODELS ILB9 ILB11 Page 3 WIRING OPTIONS WIRING PLATE POSITION ES AN VERTICAL POWER CABLE CONNECTION l d HORIZONTAL POWER CABLE CONNECTION Wiring plate mounts to side or top of housing DUCTING OPTIONS BLOWER DISCHARGE POSITIONS DUCT CONNECTOR outlet DUCT CONNECTOR outlet Housing rotated 8 movable panel covers previous open side MOVABLE PANEL PANEL Change to this location KE MOVABLE DUCT CONNECTOR intake DUCT CONNECTOR intake Ventilator shown in straight through discharge position Factory shipped Ventilator shown in right angle discharge position Change movable panel to new location as shown DUCTING Vertical blower discharge ROOF CAP 8 X 12 TO 10 ROUND TRANSITIONS 10 ROUND 10 ROUND DUCT CL SS LS Typical ductwork connection to a ventilator converted to right angle discharge BY BROAN USE AND CARE Follow wiring instructions packed with range hood and adhere to all local and state codes and the National Electrical Code WARNING To reduce the risk of electric shock disconnect from power supply before servicing
30. x sous utilisation et service normaux CETTE GARANTIE NE COUVRE PAS LES DEMARREURS DE LAMPES FLUORESCENTES ET LES TUBES Cette garantie ne couvre pas a l entretien et le service normal ou b tout produit ou pi ce endommag par suite de mauvais usage n gligence accident entretien inappropri ou r paration autre que par Broan mauvais installation ou installation contraire au mode d installation recommand La dur e de toute garantie implicite est limit e une p riode d un an tel que sp cifi pour la garantie exprim e L ENGAGEMENT DE BROAN DE R PARER OU DE REMPLACER AU CHOIX DE BROAN SERA LA SEULE OBLIGATION EXCLUSIVE SOUS CETTE GARANTIE BROAN NE SE TIENDRA PAS RESPONSABLE DES DOMMAGES DIRECTS INDIRECTS OU SP CIAUX SURVENANT A CAUSE DE OU EN RAPPORT L UTILISATION OU LA PERFORMANCE DE SES PRODUITS Cette garantie vous donne des droits l gaux sp cifiques et il se peut que vous ayez d autres droits Cette garantie annule toutes les garanties pr c dentes Pour le service sous garantie vous devez a aviser Broan l adresse ci dessous b donner le num ro du mod le et l identification de la pi ce et c d crire la nature de tout d faut dans le produit ou la pi ce Au temps de demander le service sous garantie vous devez pr senter une preuve de la date d achat original Aux E U comuniquez avec Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 Au Canada comuniquez avec Broan NuTone Canada 1140 T
31. y Nos 15 thru 25 Access Cover Access Cover Screw 4 req Hanger Kit Transition 8 x 12 to 10 Round 2 req Rough In Kit 97016795 98009532 99150472 97016791 ST463 97014597 Order replacement parts by PART NO not by KEY NO Standard hardware may be purchased locally Not shown assembled BLOWER ASSEMBLY WARRANTY BROAN ONE YEAR LIMITED WARRANTY Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan faulty installation or installation contrary to recommended installation instructions The duration of an implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts

Download Pdf Manuals

image

Related Search

Related Contents

壁、 柱、 天井等に石綿等が吹き付けられた建築物  Une association Pro-Ject / Klipsch finement réfléchie !  the MAQ®20 catalog  PDF  IAN 72315 - Lidl Service Website  StoreJet 25 mobile User`s Manual  Guia de Instalação  Trutest User Manual  Samsung SPF-72V Инструкция по использованию  Einbauanleitung für Schlüter®-BEKOTEC  