Home
Zephyr APN-M90AWX Ventilation Hood User Manual
Contents
1. gt ZEPH R www zephyronline com ATI M90ASX ATI M90ABX Tilt 54013211351 uonej e3su JOOH AONVY HOTTE PER CUISINE Notice d utilisation Pag 23 WEE campana EXTRACTORA Manual de utilizaci n Pag 45 ME ASPIRANTE istruzioni per 67 2 SAFETY INSTRUCTIONS tatnen tonto idas artist pag 4 LIST MATERIALS iiki sasiada DUCTING CALCULATION SHEETS eerte HOOD SPECIFICATION sscsisatsscssrscccsscacesscssveseshscsossss satecsaczeasisessdssssnsasaseciscesesseassstisenssussted INSTALLATION gt INTERNAL BLOWER ct m che tec Ceteros EXTERNAL amp IN LINE BLOWER PREPARATION d DUCTING OPTIONS niteretur stet a MOUNTING THE RANGE HOOD eere POWER SUPPLY MAINTENANDGE nine kie ind LIST OF PARTS AND ACCESSORIES Contents Safety instructions B IMPORTANT SAFETY INSTRUCTIONS m FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS m PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING IMPORTANT Save these Instructions for the Local Electrical Inspectors use B INSTALLER Please leave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference E Take care when using cleani
2. 8 Round 90 elbow 7 or 8 Round 45 elbow 7 or 8 Round wall cap with damper 7 or 8 Round roof cap 7 roundto 3 1 4 x 10 rect transition 7 roundto 3 1 4 x 10 rect transition 90 elbow Subtotal column 2 Subtotal column 1 Total Ductwork front of hood 35 3 8 optional duct cover With Optional Duct Cover Accessory 8 to 10 ceiling 35 52 10 or 12 ceiling min 51 max 85 top of hood Z1C 00TI B Z1C 01TI min max no cover 18 3 4 side of hood Hood Specifications www zephyronline com Installation Internal Blower NOTE The device this version with internal suction motor is equipped for rear discharge of exhaust air However if required it is possible to have the exhaust air discharged from the top This can be accomplished by following the steps indicated in the following exhaust air rear exhaust air paragraphs upon reaching step 7 the aes discharged motor plate must be rotated there 9 the top fore skip steps 8 and 9 and proceed from step 10 directly E The following instructions are for installing the internal blower CAUTION To reduce the risk of fire and electric shock install this range hood only with internal blower models MT 020 provided with the kit code CBI 600A For ex
3. air However if required it is possible to have the exhaust air discharged from the top This can be accomplished by carrying out the steps indicated in the follow ing paragraphs upon reaching step 7 the motor plate must be rotated and installed in the opposite direction ET exhaust air discharged from the top rear exhaust air discharged The following instructions for preparing the hood for use with an ex ternal or in line blowers models CBE 1000 or PBN 1000A CAUTION To reduce the risk of fire and electric shock install this rangehood only with remote blowers rated maximum 6 2 A For internal blower instructions please turn to page 10 1 Open the front panel Fig 1 NOTE Open the front panel while holding it by its external sides as shown in Fig 1 and keep at a suitable distance to avoid impacting it 2 Remove the Decorative Mesh Filters 3 Loosen the two screws inside the hood that fasten the canopy Fig 2 4 Slide the top cover off by lifting it Fig 3 Installation External amp In Line Blower Preparation www zephyronline com Installation External amp In Line Blower Preparation 5 Close the front panel while holding it by its external sides until it shuts 6 Remove the metal motor plate by striking it with the aid of a slotted screwdriver Fig 4 7 Remove the
4. on Installation Power Supply Connection Maintencance MAINTENANCE It is recommended to operate the appliance prior to cooking It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors The proper function of the range hood is conditioned by the regularity of maintenance The decorative mesh filters capture the grease particles suspended in the air and are therefore subject to clogging because of frequent use In order to pre vent a fire hazard it is recommended to clean the filter a minimum of every 2 months or when instructed by the Metal Filter Clean indicator on the range hood controls Clean the range hood by carrying out the following instructions Remove the filters from the range hood and wash them in a solution of water and neutral liquid detergent leaving to soak Rinse thoroughly with warm water and leave to dry Filters may also be washed in the dishwasher at the lowest setting The filters may alter in color after several washes but is not cause for replace ment Clean the blower and other surfaces of the range hood regularly using a cloth moistened with denatured alcohol or non abrasive liquid detergent 20 DESCRIPTION REPLACEMENT PARTS Light Bulb GU5 20W each Long Duct Cover 9 10 ceiling ZRC 00HZ ZOF 00AC Z1C O0TI Z1C O1TI To order parts visit us online at http
5. store zephyronline com or call us at 1 888 880 8368 2 List of Parts and Accessories 3LIKO505
6. tips published by NFPA Proper maintenance of the Range Hood will assure proper performance of the unit B INSTALLATION INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases Safety instructions Safety instructions through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must always be vented to the outdoors E This unit must be grounded WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK m WARNING UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE DANGEROUS A Do not check filters with hood working B Do not touch the lamps after a prolonged use of the appliance C food must be cooked flamb underneath the hood D The use of an unprotected flame is dangerous for the filters and c
7. 10 screws securing the blo wer plate to the blower housing and re move blower plate See Fig 5 8 if air is discharged from the top rotate the motor plate by 90 and fix the rectan gular plate and the fixing bracket in the opposite direction Install the chosen flange rectangular A or circular B and fix it to the blower pla te with the 4 type B screws Fig 6 9 Install the plate with the flange facing the wall inside the motor casing carry out the in structions at stage 7 in reverse order then use the screws provided to complete installation Tot 16 type B Fig 7 10 Insert the female connector in the termi nal box Fig 8A Break the hood grommet with the aid of a slotted screwdriver Fig 8B Secure remote blower junction box to top of blower housing using 2 screws See Fig 9 11 Connect the power supply conduit to the box once the hood has been fixed to the wall pag 17 Fig 10 Note Carry out the power supplly con nection in accordance with the national electric code ANSI NFPA 70 1999 Note1 A cable lock not included may be required by local codes Please review lo cal codes for more information 12 Attach 6 pin male molex connectors to 6 pin female molex connectors inside blo wer housing See Fig 11 Note2 Check local codes to determine mi nimum wire gauge See manual inc
8. ct used to exhaust hot Min 22 Max 34 air or fumes from another appliance Before pro ceeding with the assembly instructions remove the decorative mesh filters so that the range hood is esier to handle 36 MOUNTING TO THE WALL 1 Place the paper template included with your hood on the wall to determine where to add the screws for mounting the hood Make sure that the line at the bottom of the template is aligned with the edge of the rear lower corner of the hood Fig 15 k o ext blower connection Note Cut out holes for ducting if venting out the back Drill holes for the power supply and the remote blower power supply if required using the measure ments indicated in Fig 16 2 Lift the hood onto the 2 type D screws and adjust to make sure the hood is level Installation Mounting the Range Hood Installation Mounting the Range Hood WARNING In order to facilitate their connection make sure that the power supply conduits are not obstructed by the hood 3 When the hood has been adjusted tighten the screws to secure the hood in place 4 Once the adjustment has been completed fix the hood definitely using another 2 type D screws NOTE Screws must be fastened into wooden studs so wood blocking may be necessary If using wall anchors make sure to check your local codes for suita bility and type of anchors to use For the vario
9. f the motor by fixing them onto the motor plate with 4 type B screws and to the si des of the motor with another 4 type C screws Fig 9 12 Secure capacitor box connected to the provided cable to the blower plate using 2 type B screws included with the blower See fig 10 Installation Internal Blower Installation Internal Blower 13 Secure Green Yellow ground wire connected to the cable to the provided capacitor to blower plate type A Fig 11 14 Attach the 6 pin male molex connector from blower wire to the 6 pin female molex connector located inside the blower housing See Fig 12 15 Install the blower and plate on the inside of the blower housing carry out the instruc tions at step 3 in re verse order then use the screws provided to complete installa tion Tot 16 type B Fig 13 16 Open the flap Con nect 9 pin male mo lex connector from blower wire to 9 pin female molex connector on the capacitor wire See Fig 14 WARNING Place electrical wiring inside the blower housing 17 Put the Decortive Mesh Filter back on and close the front panel while holding it by its external sides until it shuts then put the canopy back on du The hood is now ready to be instal led on the wall B NOTE The device in this version with external motor is equipped for rear discharge of exhaust
10. ils slowly on low or medium settings B Always turn hood ON when cooking at high heat or when flambeing foods i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size of the surface element E Keep fan filters and grease laden surface clean Use high range setting on range only when necessary Heat oil slowly on low to medium setting G Don t leave range unattended when cooking H Always use cookware and utensils appropriate for the type and amount off food being prepared m WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out mmediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result D Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to perate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit aBased on kitchen firesafety
11. luded with external and in line blower for instructions on installing the blowe Hood Wire Harness Remote Blower Installation External amp In Line Blower Preparation Installation Ducting Options WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside unless using the recirculating op tion Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certif ed Silver Tape or Duct Tape Some Ducting Options Roof Pitch w 2 Flashing 8 Cap in line blower blower blower id housing housing side Wall cap Ss gravity damper Soffit or crawl space u N ductless N ERR 5 FU blower 1 recirculating EE housing J J NN side wall cap w gravity damper 16 MOUNTING HEIGHTS The range hood must be installed at a minimum height of 22 inches 56 cm from the cooking surface If a connecting duct work composed of two parts is used the upper part must be placed outside the lower part Do not connect the range hood duct to the same du
12. ng agents or detergents B Suitable for use in household cooking area WARNING To reduce the risk of fire or electric shock do not use this fan with any Solid State Speed Control Device CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Please read specification label on product for further information and requirements m WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have ques tions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on ac cidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smo king and greasy spillovers that may ignite Heat o
13. ould cause fires E Watch constantly the fried food in order to avoid the cooking oil flares up F before performing any mainteinance operation disconnect the hood from the electrical service E The manufacturers will not to accept any responsability for eventual damages because of failure to observe the above instructions 3511 Electrical Junction Box Light Bulbs Decorative Mesh Filters 1 4 x 2 3 4 DESCRIPTION CEN Top Cover Bl TYPE Front Panel Ducting Calculation Sheet duct pieces 3 1 4 x 10 1 Ft Rect straight 7 Round straight 8 Round straight 3 1 4 x 10 Rect 90 elbow 3 1 4 x 10 Rect 45 elbow 3 1 4 x 10 Rect 90 flat elbow 3 1 4 x 10 Rect wall cap with damper 3 1 4 x 10 Rect to 6 round transition 3 1 4 x 10 Rect to 6 round transition 90 elbow 6 Round 90 elbow 6 Round 45 elbow Subtotal column 1 Maximum Duct Length For satisfactory air movement the total duct length x Equivalent number length x used Total should not exceed 100 equivalent feet duct pieces Equivalent number length x used Total 6 8 Round 30 Ft x wall cap with damper 6 8 Round roof cap 6 roundto 3 1 4 x 10 rect transition 6 round to 3 1 4 x 10 rect transition 90 elbow 7 or
14. ternal and in line blower prepara tion please turn to page 13 1 Open the front panel Fig 1 NOTE Open the front panel while holding it by its external sides as shown in Fig 1 and keep at a suitable distance to avoid impacting it 2 Remove the Decorative Mesh Filters 3 Loosen the two screws inside the hood that fasten the canopy Fig 2 5 Close the front panel while holding it by its exter nal sides until it shuts 4 Slide the top cover off by lifting it Fig 3 7 6 Remove the 6 round metal knockout pla te from the blower plate by using a flat head screwdriver See Fig 4 7 Remove the 10 screws securing the blo wer plate to the blower housing and remo ve blower plate See Fig 5 Note If air is discharged from the top do not rotate the plate proceed from step 10 in stead 8 Remove the rectangular plate and the fi xing bracket from the motor plate by loo sening the 6 screws Fig 6 9 Rotate the motor plate by 90 and fix the rectangular plate and the fixing bracket in the opposite direction as shown in Fig 7 10 Place the 6 metallic flan ge on the blo wer s air outlet the flange may already be pre installed Install internal blower into blower plate and secure using 4 screws included with the blower See Fig 8 11 Fasten the two brackets to the sides o
15. us installations use screws and screw anchors suited to the type of wall minimum screw size 1 4 diameter x 2 3 4 length NOTE2 The following Duct Cover kits are available as acessories 21 00 Z1C OTTI m GENERAL Carefully read the following important information regarding installation safety and maintenance Keep this information booklet accessible for further consultations m POWER SUPPLY CONNECTION For connection to the power supply refer to the following 1 Remove the power supply cover by undoing the 2 screws Fig 17 2 Break through the hole on the box 3 Pass the wires through the hole in the box and fasten the power supply conduit Fig 18 4 Connect the wires of the hood to those of the power supply as described Fig 19 BLACK L line WHITE N neutral GREEN YELLOW G ground A double pole switch properly rated must be installed to provide the range hood power supply disconnection Connect the electrical conduit to the Field Wiring Compartment using listed onduit fittings Carry out the power supplly connection in accordance with the national electric code ANSI NFPA 70 1999 5 Insert the wires into the box then close the box cover securing it using the screws that were previously removed 6 Put the Decortive Mesh Filter back on and clo se the front panel while holding it by its external sides until it shuts then put the canopy back