Home

Zephyr ALL-E42ABX Ventilation Hood User Manual

image

Contents

1. 5 Replace the lid by following the instructions from step 3 in reverse order ensu ring that the tab on the lid is within the enclosure 6 Remove adhesive tape and lower the bottom duct cover so it rests on top of the hood body 221 Installation Power Supply Connection Maintencance B MAINTENANCE e It is recommended to operate the appliance prior to cooking It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors The proper function of the range hood is conditioned by the regularity of maintenance The decorative mesh filters capture the grease particles suspended in the air and are therefore subject to clogging because of frequent use In order to pre vent a fire hazard it is recommended to clean the filter a minimum of every 2 months or when instructed by the Metal Filter Clean indicator on the range hood controls Clean the range hood by carrying out the following instructions Remove the filters from the range hood and wash them in a solution of water and neutral liquid detergent leaving to soak Rinse thoroughly with warm water and leave to dry Filters may also be washed in the dishwasher at the lowest setting The filters may alter in color after several washes but is not cause for replace ment Clean the blower and other surfaces of the range hood regularly using a cloth moistened with denatured alcoho
2. Never leave surface units unattended at high settings Boilovers cause smo king and greasy spillovers that may ignite Heat oils slowly on low or medium settings B Always turn hood ON when cooking at high heat or when flambeing foods Le Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe C Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size of the surface element E Keep fan filters and grease laden surface clean F Use high range setting on range only when necessary Heat oil slowly on low to medium setting G Don t leave range unattended when cooking H Always use cookware and utensils appropriate for the type and amount off food being prepared E WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out mmediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result D Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to perate it 2 The fire is small and contained in the area where it started 3 The f
3. 4 Installation Mounting the Range Hood into the attic to connect after the hood is installed Fig 11 3 Place assembled support frames on top of hood and secure it to the hood body using 8 type screws Fig 12 4 Place duct covers over assembled support frame until they rest on Installation Mounting the Range Hood the hood body Fig 13 Note If you ordered a wood trim piece or re circulating kit please refer to the instructions included inside the kits prior to installing the hood to the ceiling 5 Position hole template on the ceiling paying at tention that the arrow is positioned on the same side as the range hood controls Make 4 holes in the ceiling and drive in 3 type C screws without completely tightening them Pay attention not to insert the screw into the hole marked with an X on the hole template Fig 14 6 Lift the hood assembly to the ceiling and align the top support frame with the 3 screws previously installed in the ceiling Rotate assembly slightly clockwise to lock in place Fig 15A Drive in the fourth screw type C and tighten the remaining 3 screws to secure the structure in place Fig 15B 7 Extend the upper duct cover and secure it to the top support frame by using 2 type B screws Fig 16 8 Verify that ducting from hood is connected to ducting in the attic that will exhaust air out of the home NOTE For the
4. ARC ZEPHR COLLECTION www zephyronline com Duo ls ADL M90ASX ADL E42ASX Layers Is ALL M90ABX ALL M90AWX ALL E42AWX ALL E42ABX 5 Uer ion instructions RANGE HOOD Installat HOTTE PER CUISINE Notice d utilisation Pag 25 WE campana EXTRACTORA Manual de utilizacion Pag 48 MIE CAPPA ASPIRANTE istruzioni per l uso Pag 73 SAFETY INSIRULTIONS lindas pag 4 LIS TDEMATERIAES pag 7 DUCTING CALCULATION SHEET S pag 9 HOOD coil pag 10 INSTALLATION INTERNAL BLOW EGR manemane pag 12 EXTERNAL amp IN LINE BLOWER PREPARATION pag 14 IDUCTING OPTIONS ucraniana pag 16 MOUNTING THE pag 17 POWER SUPPLY pag 20 MAINTENANCE usadas o tal pag 22 LIST OF PARTS AND 5 5 pag 23 Contents Safety instructions E IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS B PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING E IMPORTANT Save these Instructions for the Local Electrical Inspectors use E INSTALLER Please leave these Instructi
5. Fig 4 5 Pass the wires of the remote motor through the hole in the cover that was previously removed and connect them with those of the connector located in the enclosure Fig 5 Note Carry out the power supplly connection in accordance with the national electric code ANSI NFPA 70 1999 1 cable lock not included may be re guired by local codes Please review local co des for more information 6 Reinstall the cover on the motor housing by following the instructions from step 2 in re verse order 7 Attach 6 pin male molex connectors to 6 pin female molex connectors inside blower hou sing See Fig 6 Note2 Check local codes to determine mini mum wire gauge See manual included with external and in line blower for instructions on installing the blower Hood Wire Harness Installation External amp In Line Blower Preparation Installation Ducting Options m WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside unless using the recirculating op tion Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Roof Pitch w Flashing amp Cap AA in line blower blo
6. flat elbow 3 1 4 x 10 Rect wall cap with damper 3 1 4 x 10 Rect to 6 round transition 3 1 4 x 10 Rect to 6 round transition 90 elbow 6 Round 90 elbow Subtotal column 1 Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet duct pieces Equivalent number length x used Tota 6 8 Round 30 Ft x wall cap with damper 6 8 Round 30 Ft roof cap 6 roundto 3 1 4 x 10 rect transition 6 roundto 3 1 4 x 10 rect transition 90 elbow 7 or 8 Round 90 elbow 7 or 8 Round 45 elbow 7 or 8 Round wall cap with damper 7 or 8 Round roof cap 7 round to 3 1 4 x 10 rect transition 7 round to 3 1 4 x 10 rect transition 90 elbow Subtotal column 2 Subtotal column 1 Total Ductwork Ducting Calculation Sheet Wi Models ADL M90ASX ADL E42ASX front of hood side of hood Ale 15 16 _11 3 16 Hood Specification min ducted 30 min recirc 30 max 34 blower housing 11 7 8 35 7 16 or 42 23 5 8 top of hood blower connection 9 1 4 C 15 8 elec k o 6 11 16 c 7 1 2 front 35 3 8 or 42 Wood Trim Dimensions 1 5 8 Thick
7. ire department is being called 4 You can fight the fire with your back to an exit aBased on kitchen firesafety tips published by NFPA Proper maintenance of the Range Hood will assure proper performance of the unit E INSTALLATION INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases Safety instructions Safety instructions through the flue chimney of fuel burning eguipment to prevent back drafting Follow the heating eguipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must always be vented to the outdoors E This unit must be grounded B WARNING TO REDUCE RISK OF FIRE USE ONLY METAL DUCTWORK E WARNING UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE DANGEROUS A Do not check filters with hood working B Do not touch the lamps after a prolonged use of the appliance C No food mu
8. l or non abrasive liquid detergent 2224 A OPTIONAL ACCESSORIES To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 23 List of Parts and Accessories 2942 3LIKO500
9. motor support bracket securing it using the 2 type B screws Fig 5 6 Attach the 6 pin male molex connector from blower wire to the 6 pin female molex con nector located inside the blower housing See Fig 6 7 Install the motor and bracket inside the motor housing completing the installation using the other screws 6 type B that have been sup plied Tot 13 type B Fig 7 8 Connect 9 pin male molex connector from blower wire to 9 pin female molex connector on the capacitor wire See Fig 8 WARNING Place electrical wiring inside the blower hou sing The hood is now ready to be installed on the wall Installation Internal Blower Installation External amp In Line Blower Preparation The following instructions are for preparing the hood for use with an ex ternal or in line blowers models CBE 1000 or PBN 1000A CAUTION To reduce the risk of fire and electric shock install this rangehood only with remote blowers rated maximum 6 2 A For internal blower instructions please turn to page 12 1 Break out the partially pre cut circle in the lid located on the remote motor sup port bracket using a flat head screwdriver Fig 1 2 Remove the cover by un doing the 3 screws Fig 2 3 Secure 8 round blower collar to top of blower housing using 4 type B screws Fig 3 4 Insert the female connector into the remote motor support bracket enclosure
10. ness 10 Models ALL M90AWX ALL E42AWX ALL E42ABX front of hood 12 15 16 30 min ducted 30 min recirc A blower gt h 0 ousing 27 9 16 35 7 16 42 max 34 side of hood _11 3 16 16 9 16 26 top of hood L 6 11 16 n a 7 1 2 9 1 4 5 Hood Specifications Installation Internal Blower The following instructions are for installing the internal blower CAUTION To reduce the risk of fire and electric shock install this range hood only with internal blower models MT 020 provided with the kit cod CBI 600A For external and in line blower preparation please turn to page 14 1 Remove the 7 screws securing the remote motor support bracket to the motor housing and then remove the bracket See Fig 1 2 Insert the 6 sheet metal flange in the motor air exhaust outlet Fig 2A Then insert the plate supplied with the motor and secure all parts using the 4 screws Fig2B 3 Secure the condenser connected to the supplied wire to the bracket using the 2 type B screws See Fig 3 4 Secure the green yellow ground wire connected to the wire supplied with the condenser using the screw on the bra cket type A Fig 4 5 Connect the plate and the motor on the remote
11. ons with this unit for the owner m OWNER Please retain these instructions for future reference Take care when using cleaning agents or detergents Suitable for use in household cooking area WARNING To reduce the risk of fire or electric shock do not use this fan with any Solid State Speed Control Device m CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Please read specification label on product for further information and requirements E WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have ques tions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on ac cidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A
12. st be cooked flamb underneath the hood D The use of an unprotected flame is dangerous for the filters and could cause fires E Watch constantly the fried food in order to avoid the cooking oil flares up F before performing any mainteinance operation disconnect the hood from the electrical service WARNING For models ADL M90ASX and ADL E42ASX never lean on the hood s body any object weighing more than 33 116 15kg although evenly spread over the whole surface The manufacturers will not to accept any responsability for eventual damages because of failure to observe the above instructions Models ADL M90ASX ADL E42ASX Duct Covers Support Frame Assembly Blower Housing Control Range Hood Body Light Panel Light Bulbs Decorative Mesh Filters Cm EI List of Materials List of Materials Models ALL M90ABX ALL M90AWX ALL E42AWX ALL E42ABX Duct Covers Support Frame Assembly Blower Housing Control Range Hood Body Light Bulbs Decorative Mesh Filters mec __ DESCRIPTION ACE KAE Eguivalent number duct pieces length used Total 3 1 4 x 10 1 Ft Rect straight 7 Round straight 8 Round straight 3 1 4 x 10 Rect 90 elbow 3 1 4 x 10 Rect 45 elbow 3 1 4 x 10 Rect 90
13. various installations use screws and screw anchors suited to the type of ceiling minimum screw size 1 4 diameter x 2 3 4 length Installation Mounting the Range Hood Installation Power Supply Connection GENERAL Carefully read the following important information regarding installation safety and maintenance Keep this information booklet accessible for further consultations POWER SUPPLY CONNECTION For connection to the power supply refer to the following 1 Temporarily join the two duct covers by lifting the bottom one and then carefully securing it to the top by using adhesive tape Fig 17 Take care not to scratch the duct covers 2 Break out the partially pre cut circle in the cover of the mains power connection en closure using a flat head screwdriver Fig 18 3 Remove the power supply cover by un doing the 2 screws Fig 19 4 Connect the supply conduit to the cover then connect the hood to the power sup ply by making the following connections Fig 20 BLACK L line WHITE N neutral GREEN YELLOW G ground A double pole switch properly rated must be installed to provide the range hood po wer supply disconnection 20 Connect the electrical conduit to the Field Wiring Compartment using listed onduit fittings Carry out the power supplly connection in accordance with the national electric code ANSI NFPA 70 1999
14. wer Tower housing housing ss side wall cap w gravity damper Soffit or crawl space 1 ductless blower recirculating housing 16 B MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches 61 cm from the cooking surface If a connecting duct work composed of two parts is used the upper part must be placed outside the lower part Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance Before proceeding with the assembly instructions remove the decorative mesh filters so that the range hood is easier to handle MOUNTING TO THE CEILING The following instructions assume the installer has access to the attic or crawl space Each installation may be unique to the home 1 Remove the 2 screws to unlock the top support frame from the bottom support frame Fig 9 Adjust the height by referring to the diagram in Fig 8 Secure the support frames together with 2 type B screws per extension arm Tot 8 type B Fig 10 2 Place correct size ducting for your installation not supplied on top of hood and secure to the blower collar with aluminum duct tape The ducting should be long enou gh so it protrudes out the top of the support frame and extends 24 X C 4 3 1 16 2

Download Pdf Manuals