Zephyr AK8000AS Ventilation Hood User Manual

image

Contents

1. Min 24 Max 32 36 DUCTING AK8000AS AK8100S AK8200S A minimum of 6 round or 3 1 4 x 10 rectangular duct must be used to maintain maximum air flow efficiency for AK8000 AK8100 and 8 minimum must be used for AK8200 Always use rigid type metal ducts only Flexible ducts could restrict air flow by up to 50 Also use calculation on right to compute total available duct run when using elbows transitions and caps ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from open ing as possible If turns or transitions are required Install as far away from opening and as far apart between 2 as possible Minimum mount height between range top to hood bottom should be no less than 24 Maximum mount height should be no higher than 32 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire haz ard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer range manufacturer s height clearance requirements and recom mended hood mounting height above range Minimum clearance of 24 hood above range height Maximum clearance 32 hood above range height Minimum
2. d Use proper pan size Always use cookware appropriate for the size of the surface element e Keep fan filters and grease laden surfaces clean f Use high setting on hood only when necessary g Don t leave hood unattended when cooking h Always use cookware and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result www zephyronline com d Use an extinguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards Including fire rated construction b Sufficient air is needed for power combustion and exhausting of gases through
3. 8 cut out j A a 26 7 8 nyt cut out sa cut out dimension Page 3 INSTALLATION INSTALLATION SPECIFICATIONS SPECIFICATIONS Tornado 1 unit AK8100S Tornado 2 unit AK8200S 33 7 16 26 19 32 16 3 16 11 3 16 A S E ee 10 5 16 15 9 32 shee Zs O 27 9 16 34 7 16 9 27 32 2 3 8 7 718 N X lt 27 9 16 46 2 13 16 6 34 7 16 B 1 3 8 a i h 1 2 Elec K O T l 5 11 3 16 1 2 Elec K O 5 1 8 16 3 16 C j 10 CIL oL PAAA EE 7 cut out dimension 10 5 8 cut out cut out dimension 15 3 8 cut out lans L K 26 7 8 cut out panus cut out dimension T l 33 1 I2 A NT OEO O p cut out er cutout dimension EE TE Page 4 Page 5 INSTALLATION INSTALLATION Mounting the Range Hood Front View 1 Determine and mark the mounting wood frame B wood frame position of the range hood with a pencil uo pin 2 Cut out the opening where the range aN L hood will be installed 3 Cut out wall or ceiling area for clearance of ductwork Install ductwork prior to range hood 4 Determine location for the power supply cable After drilling access hole Ne i Controls T Pa Power Supply cable rout the cable into the electrical box Locking clip Entry i
4. Duct Size Round 6 minimum for AK8000AS AK8100S 8 minimum for AK8200S Rectangular Requires an adapter Readily available at most hardware stores Duct Run Calculation Maximum run AK8000 AK8100 6 or 3 1 4 x 10 AK8200 8 100 FT Deduct each 90 Elbow used 15 FT each 45 elbow used 9 FT each 6 to 3 14 x 10 transition used 1 FT each 3 14 x 10 to 6 each 3 14 x 10 to 6 transition used 5 FT Side Wall Cap w damper 30 FT Roof Cap 30 FT e g 1 roof cap 2x90 elbows 1 45 elbow used 30 30 9 69 used 31 available for straight duct runs Page 1 INSTALLATION DUCTING WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Pa mas C ij H 7 l posses e side wall cap side wall cap w giavity damper w gravity damper Soffit or crawl space Roof Pitch w Flashing amp Cap Page 2 INSTALLATION SPECIFICATIONS Twister AK8000AS 10 11 as 2 eo FRONT C L EES AR cut out dimension 1 0 5
5. T touch bulb until switched off and cooled Touching hot bulbs could cause serious burns Make sure all power is turned off and bulbs are not hot Remove by turning bulb counter clockwise If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approx the diameter of the bulb and turn Replacement bulbs are available at specialty lighting stores Purchase type GU 10 120V 35W halogen bulbs Or to order bulbs please call our service center 888 880 8368or online parts store www zephyronline com Page 10
6. TURES AK8100S AK8200S Speed Selection Lights On Off why O sd OD Speed Selection This switch controls the speed of the blower The first position is low speed the second is medium speed and the third is high speed Lights On Off Turn lights on or off by moving this switch CONTROLS amp FEATURES AK8000AS Blower On Off Speed Selection Lights Bright Dim Off Speed Selection This switch controls the speed of the blower is low speed lI is medium speed and III is high speed Lights Bright Dim Off This switch controls the lights Slide switch to fordim lighting and II for bright lighting Page 7 MAINTENANCE CLEANING AK8100S AK8200S Models AK8100S and AK8200S hoods are designed with a self cleaning feature The centrifigal blower system automatically liquefies cooking residue accumulated in its internal housing and deposits the residue in the residue cups Nevertheless grease from cooking can also dry and adhere in the internal housing Running the self clean function periodically will flush out accumulated residue in the range hood s internal housing Cleaning should be completed approximately once a month under normal use Non corrosive non abrasive grease cutting spray detergents are recommended Self Cleaning Instructions Remove safety grilles by unscrewing the thumb screw on each grille Turn blowers on lowest speed for cleaning With no
7. Use Care and Installation Guide Read all Instructions before Installing and operating this appliance Important Safety Notice Read and save these instructions Important Safety Notice MODEL AK8000AS AK8100S AK8200S READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE CONTROL DEVICE WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer if you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors Take care when using cleaning agents or detergents Suitable for use in household cooking area WARNING TO REDUCE THE RISK OF RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flaming food c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter
8. nto range hood of the range hood Secure with a cable lock and connect to range hood Side View electrical system wood frame Tf wood frame 5 Position range hood into location and ensure spring locking clip has locked into position T 6 Fasten wood screws into wood frame opening via the long side Wood blocking 7 may be necessary if wood frame is too thin AGr ELECTRICAL coo oo wood WARNING blocking All Electrical work must by performed by qualified electrician or person with similar technical know how and background For personal safety remove house fuse or open circuit breaker before beginning installation Do not use extension cord or adapter plug with this appliance Attach 2 screws to each long side of AK8100 AK8200 Follow National electrical codes or prevailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please also refer Electrical Diagram labeled on product Cable Lock A cable locking connector not supplied might also required by local codes Check with local l requirements and codes purchase and install appropriate connector if necessary el eh Se ee CONTROLS amp FEATURES CONTROLS amp FEA
9. the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities c When cuttig or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities d Ducted fans must always vent to the outdoors e If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCL Ground Fault Interrupter protected branch circuit g NEVER place a switch where it can be reached from a tub or shower h Make sure the power is off before installing wiring or maintenancing WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK CAUTION To reduce risk of fire and to properly exhaust air outside Do not vent exhaust air into spaces within walls ceilings attics crawl spaces or garages WARNING TO REDUCE THE RISK OF SHOCK THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL CONTROL SWITCH OPERATION Always leave safety grills and filters in place Without these components operating blowers could catch onto hair fingers and loose clothing NOTE Please check www zephyronline com for revisions before doing any custom work INSTALLATION MOUNT HEIGHTS
10. zzle on spray squirt grease cutting detergent directly onto blower blades 10 15 times Do not use oven cleaner Allow self cleaning to complete for 5 minutes turn blower off Remove residue cups Clean with mild detergent or in dishwasher Re install residue cups and safety grilles before using hood Slide off to remove residue cups Page 8 MAINTENANCE CLEANING AK8000AS The AK8000AS metal mesh filter fitted by the factory is intended to filter out residue and grease from cooking It need not be replaced on a regular basis but is required to be kept clean Filter should be cleaned every 30 days based on a usage of 1 hour per day Clean filter more often if performance decreases Remove and clean by hand or in dishwasher on low setting Or spray degreasing detergent and leave to soak if heavily soiled Dry filter and re install before using hood Should filter wear out due to age and prolonged use contact the manufacturer SURFACE MAINTENANCE AK8000AS AK8100S AK8200S Clean periodically with hot soapy water and clean cotton cloth Do not use corrosive or abrasive detergent or steel wool scouring pads which will scratch and damage surface For heavier soil use liquid degreaser Do not use any product containing chlorine bleach Do not use orange cleaners Page 9 MAINTENANCE LIGHTS Replacing Light Bulbs CAUTION Light bulb becomes extremely hot when turned on DO NO