Home

Yamaha i88X Musical Instrument User Manual

image

Contents

1. Eject lever Eject lever Eject levers 6 Attach the plug in board loose proof assembly and the Name of option Name of board Slot on the front side front panel by reversing the installation steps 2 3 MKE 9040M DVP 24A board 3 4 5 6 1 The DVP 24A boards are assigned to the following channels in accordance with the slots to which the boards are inserted Slot Channel 3 CH1 4 CH2 5 CH3 6 CH4 MVE 9000 IM 1 5 1 4 2 Installing the Connector Board In the case of MKE 9020M Parts required Supplied accessory of MKE 9020M The board slot Connecting cable e Harness support Name of option Name of board Slot on the rear side Cover panel MKE 9020M CN 2357A board 3 e Screws Two of PSW3 x 6 CN 2357B board 5 MKE 9021M CN 2355A board 3 Perform the following procedures after step 1 CN 2355B board 5 2 While the board levers are kept open as shown in the illustration insert the connector board into the board Installation procedure guide rails 1 Remove the two screws and remove the blank panel 3 While closing the board levers in the direction of arrow 1 push in the connector board and secure it Store the removed blank panel in a safe location with the two screws The following procedures vary with the options In the case of other than MKE 9020M 2 Insert the connector board horizontally level and secure it with the two fixing screws Board lever Board lever Continued Connector board Fixing screw
2. Used for maintenance purpose S3601 H 3 CPU B CONFIG switch Used for maintenance purpose 3801 H 2 SETUP A switch Used for maintenance purpose 3901 H 5 SETUP B switch Used for maintenance purpose lt Connector gt CN3502 H 4 USB A terminal Used for maintenance purpose CN3503 H 3 COM A terminal Used for maintenance purpose CN3602 H 3 COM B terminal Used for maintenance purpose CN4301 H 4 EPR terminal Used for maintenance purpose CN4601 H 3 IEEE1394 terminal Used for maintenance purpose lt TEST terminal gt E201 B 7 E202 D 7 E301 C 7 E302 F 7 E401 G 7 E501 H 5 GND terminal Use this terminal as the earth point for measuring the respective check terminals TP201 B 7 1 5 V 1 20 A check terminal 1 5 V 1 20 A measuring terminal TP202 D 7 1 5 V 2 20 A check terminal 1 5 V 2 20 A measuring terminal TP301 C 7 2 5 V 1 20 A check terminal 2 5 V 1 20 A measuring terminal TP302 F 7 2 5 V 2 20 A check terminal 2 5 V 2 20 A measuring terminal TP401 G 7 3 3 V 20 A check terminal 3 3 V 20 A measuring terminal MVE 9000 IM TP501 H 5 1 5 V 1 check terminal 1 5 V 1 measuring terminal TP502 H 5 2 5 V 1 check terminal 2 5 V 1 measuring terminal TP503 H 5 3 3 V check terminal 3 3 V measuring terminal TP504 H 5 1 5 V 2 check terminal 1 5 V 2 measuring terminal TP505 H 5 2 5 V
3. 1 6 MVE 9000 IM 4 Remove the blank panel from the slots 2 and 4 1 4 3 Installing the HK PSU04 5 Attach the cover panel and secure it with the two Screws The HK PSU04 is used after it is installed in the MVE 9000 Before installing the HK PSU04 be sure to turn off the main power If the HK PSU04 is installed while the main power is turned on it can result in electrical shock or damage to printed circuit boards Installation procedure 1 Remove the front panel of the MVE 9000 Refer to Section 1 4 1 2 Remove the two screws B3 X 5 fixing the PS cover and remove the PS cover 3 Remove the two screws PSW3 X 6 fixing the blank panel and remove the blank panel Store the removed blank panel in a safe place 6 Attach the connecting cable on the harness support 7 Connect the connecting cable to the connector 8 Secure the harness support to the cover panel using the two screws supplied with MKE 9020M LILHA OUG YW Y PS cover 4 Push the portion of the HK PSU04 indicated by the arrow and insert the HK PSU04 into deep end as far as 1t will go 5 Secure the HK PSU04 with the two screws removed in step 3 PSW3 x 6 Connecting cable HK PSU04 Q Q Q Q Q N Q Ke Y Harness support PSW3 x 6 ILILILILT LV 7 7 6 Install the PS cover and the front panel by reversing the installation steps of 1 2 MVE 9000 IM 1 7 1 5 Rack Mounting The MVE 9000 installs
4. lt LED on the CPU DR module gt Main CPU D10 green A 1 RUN status LED RUN status indication Lit when the CPU DR module starts operating D12 green A 4 CD Card Detect status LED Lit when the CPU DR module is inserted correctly into the parent board D13 green A 1 2 5 V Indicates the statue of the 2 5 V power that is generated by the VCC CORE and supplied to the CPU DR module Lit while the specified power is turned on D14 D15 D16 D17 A 3 green STATUS1 to STATUS4 status LED Used for maintenance purpose Only the STATUS1 LED is lit in normal operation D18 green A 4 3 3 V Indicates the statue of the VCC I O power that is sup plied to the CPU DR module Lit while the specified power is turned on D19 green A 4 CORE status LED Indicates the statue of the VCC CORE power that is supplied to the CPU DR module Lit while the specified power is turned on lt Switch on the CPU DR module gt Main CPU SW1 A 1 RESET switch Pressing this switch resets the CPU DR module In some machines in which the CPU DR module is installed the system reset may be activated SW2 A 2 MODE switch 8 pin DIP switch Used only for production in the assembly factory All switches are set to OFF for normal operation Default setting when shipped from the factory is all OFF MVE 9000 IM lt LED on the CPU DK module gt COM CPU 1 COM CPU 2 DI1 green B 5 CD Card Detect
5. Monitor Bop OOO0000000000000 PRIMARY INPUTS 69 80 MVS 8400 8300 8200 Switcher Processor Pack 100 to 240 V AC power supply b 100 to 240 V AC power supply Video input signal gt Video output signal Lx Video key signal ae ee Cable with 68 pin connectors AC power supply a For the AC power cord of this unit refer to Section 1 2 Power Supply in this manual b For the AC power cord of the MVS 8000 refer to Section 1 2 Power Supply in the MVS 8400 8300 8200 Installation Manual c Terminate with the supplied 75 Q terminators Terminators are supplied in the product package 1 23 MVE 9000 IM Connection Example of the MVS 8000 System MKE 9021M Installed Reference video signal B Ethernet switch Ethernet switch MVE 9000 C DME Processor Pack BVE 9100 Editing Control System Reference video signal P DATA REMOTE 1 e gt COP 3 __ PERIPH Em MKS 8010 System Control Unit q00000000000000000000 t i es i i iy e e Eeg e 900000000000000000 EE 00000000000000000 5 OOO OOOO OOOO OOO EE 0000000000000000 0000000000000000 0 0 00000000000000 00 00000000000000 Reference video signal b q00000000000000000000 q0000000000000 OO OO FON AN Q a
6. S101 A 3 Mode setting switch for the main CPU Sets the modes of the main CPU Default setting when shipped from the factory 1s all OFF S102 A 2 Group ID setting switch for LAN Sets the group ID for connecting LAN For details refer to MVS 8000 System Setup Manual S103 A 2 Unit ID setting switch for LAN Sets the unit ID for connecting LAN For details refer to MVS 8000 System Setup Manual S104 A 4 Monitor reset switch for the main CPU Pressing this switch resets the system while maintaining this unit through the main CPU control terminal connector S401 A 1 System reset switch Pressing this switch activates the system reset and the system re starts S402 A 1 CA CPU reset switch Pressing this switch resets the CA 54CFA board S403 B 1 Switch setting the number of the power supply units Setting switch for the number of the power supply units that 1s required for this unit Do not change the settings By the default setting when shipped from the factory the bit 1 and 2 are set to ON and the bit 3 and 4 are set to OFF S901 A 4 Monitor reset switch for the COM CPU 1 Pressing this switch resets the system while maintaining this unit through the COM CPU 1 control terminal S902 A 4 Modes setting switch for the COM CPU 1 Sets the modes of the COM CPU 1 Default setting when shipped from the factory is all OFF 1101 A 4 Monitor reset switch for the COM CPU 2 Pressing thi
7. The MVE 9000 C is shipped from the factory with the necessary option refer to the following table already installed in the MVE 9000 in accordance with the speci fied system configuration MVE 9000 C options Model name Board configuration Plug in board Connector board MKE 9020M CN 2357A board MVS Interface Board Set CN 2357B board MKE 9021M CN 2355A board Input Output Board Set CN 2355B board MKE 9040M DVP 24A board Advanced Effects Board HK PSU04 Power Supply Unit 1 4 1 Installing the Plug in Boards Be sure to turn off the POWER switch and unplug the power cord from the wall outlet before starting the installa tion work If the installation work is started with the POWER switch left on it may cause electrical shock or damage of printed circuit boards Installation procedure 1 Turn off the main power of the MVE 9000 and disconnect the AC power cord from the wall outlet 2 Loosen the four screws with drop safe and remove the front panel in the direction of the arrow Screws with drop safe Front panel with drop safe 3 Remove the four screws B3 X 5 and remove the plug in board loose proof assembly Plug in board loose proof assembly MVE 9000 IM 4 While the eject levers are kept open as shown in the 5 While closing the eject levers in the direction of arrow illustration insert the plug in board into the board D push in the plug in board guide rails
8. B 1 REF EXT status LED Lit while sync signal is input to the reference input D200 B 1 LOCK status LED Lit while the machine is locked to the reference signal MVE 9000 IM 2 DVP 24A board MKE 9040M lt LED gt D501 H 5 1 5 V 1 1 5 V 1 power supply status indication Lit when the 1 5 V 1 power is supplied D502 H 5 2 5 V 1 2 5 V 1 power supply status indication Lit when the 2 5 V 1 power 1s supplied D503 H 5 3 3 V 3 3 V power supply status indication Lit when the 3 3 V power 1s supplied D504 H 5 1 5 V 2 1 5 V 2 power supply status indication Lit when the 1 5 V 2 power 1s supplied D505 H 5 2 5 V 2 2 5 V 2 power supply status indication Lit when the 2 5 V 2 power 1s supplied D506 H 5 12 V 12 V power supply status indication Lit when the 12 V power 1s supplied MVE 9000 IM TP3801 Be TP3802 D3802 TP3803 D3803 L TP3804 D3804 D3701 D1301 D3703 D1302 D3702 D1303 D3704 ND3802 ND3801 CN4601 S3501 CN3503 TP3091 TP302 TP401 Aer e H TP3903 TP3904 a E302 E401 A side Component side D1301 H 2 BUS A status LED Lit when CPU A accesses the FPGA D1302 H 2 BUS B status LED Lit when CPU B accesses the FPGA D1303 H 2 READ status LED Lit when CPU A or B makes the read access to the FPGA D3701 H 2 BOOT DONE status LED Lit when IC108 starts up D3702 H 2 DLKD status LED Lit wh
9. CTRL and DATA b Terminate with the supplied 75 terminators ENER LAN networks be configured by connecting Terminators are supplied in the product separate Ethernet switches for each LAN package However it is also possible to make connections for both LANs on a single Ethernet switch 1 22 MVE 9000 IM Flow of Video Signals MKE 9020M Installed The figure below shows the flow of video signals in a MVS 8000 system MVE 9000 C DME Processor Pack SWITCHER A SWITCHER B gt i MONI OUT 9 TFTP CIFF O e5 O owo Bloen 9000000000 Monitor elo ole 0000000000 9000000000 o oe ek 100 to 240 V AC power supply 2 Reference video signal Reference video signal oyo oao DME 1B 100 to 240 V AC power supply Hl 100 to 240 V AC power p dE SS E gt Sr DME 1A supply vV0000000000000000000 A 90000000000000 D y le ES 00000 0000 a O a O E E O DO o Camera VTR PRIMARY INPUTS 1 68 routing switcher R00000000000000000y 00000000000000000 00000000000000000 00000000000000000 a Q VTR 60000000000000000 d 56b0000000000000000 d Q OUTPUTS 1 48 GO 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DH 0 0 0 0 0 0 0 0 0 0 0 0 0 0 q ip O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 y ip O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 y MONITOR OUTPUTS 1 8
10. No 10001 and Higher HK PSU04 Serial No 10001 and Higher MKE 9020M Serial No 10001 and Higher MKE 9021M Serial No 10001 and Higher MKE 9040M Serial No 10001 and Higher MVE 9000 IM For MVE 9000 Attention when the product is installed in Rack 1 Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack please make sure that the rack does not overload the supply circuit Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the rack please confirm that the outlet is provided with a suitable protective earth connection Internal air ambient temperature of the rack When this product is installed in a rack please make sure that the internal air ambient temperature of the rack is within the specified limit of this product Prevention against achieving hazardous condition due to uneven mechanical loading When this product is installed in a rack please make sure that the rack does not achieve hazardous condition due to uneven mechanical loading Install the equipment while taking the operating temperature of the equipment into consideration For the operating temperature of the equipment refer to the specifications of the Operation Manual When performing the installation keep the rear of the unit 10 cm 4 inches or more away from walls in order to obtain proper exhaust
11. and radiation of heat For MVE 9000 When using a LAN cable For safety do not connect to the connector for peripheral device wiring that might have excessive voltage MVE 9000 IM MVE 9000 IM Table of Contents Manual Structure REECH ee e 2 Related montai a aaa 2 COMES E E OE iia 2 Trade matando 2 1 Installation l i Op ratino Environment E 1 1 12 Powersupply EE 1 1 1212 POWEer DEET us ia Ee 1 1 122 Recommended Power Cord sinea n 1 2 1 3 Installation Space External dimensions oocccnccnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnonnnnnnnss 1 3 54 Anstaline the E 1 4 1 4 1 Installing the Plug in Board 1 4 1 4 2 Installing the Connector Board occcccnncncncnnnonononononnnnnnnnnnnnnnnss 1 6 14 37 Installing the HK PSUO4 su a a 1 7 ES Rack MOI 1 8 1 6 Matching Connectors and Cables eeeeeenseenneeessssssssssssssssssssssssssssssssseese 1 10 1 7 Input Output Signals of Connectors ooooonnnnnnnnncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnos 1 11 1 8 Checks on Completion of Installation eeesneenneeeeeeesssessssessseessseeeesseeeeee 1 12 1 8 1 On board Switches Setting and LED Functions 1 12 9 System COMME CHO de 1 22 2 Service Overview Ze Kee EE 2 1 2 2 Periodic Inspection and Maintenance iv sci scccanccitecateticticsacecdccteaseatacnesaass 2 2 Deals e 2 2 2 3 About the Data Backup Capacitor oooooonnnnonnnnnnnnncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnonnnnnos 2 2 Pu
12. set in the Factory Set mode check to see YES About the Factory Set refer to Chapter Engineering Setup of the MVS 8000 System User s Guide The MVE 9000 is probably defective GC lt m co O O O z 2 2 Periodic Inspection and Maintenance 2 2 1 Cleaning Front panel The filter on the rear of the front panel can easily accumulate the dust Be sure to remove dust by cleaning as follows 1 Remove the front panel Refer to Section 1 4 1 2 Remove the dust accumulated on the filter with a TA cleaner Note Cleaning the filter by washing in water is recommend ed when there is a heavy accumulation of dust Be sure to dry the filter completely after it has been washed Front panel N Q Q S Filter Fan If dust has accumulated in the intake of the fan air is prevented from flowing smoothly and this may result in a temperature rise inside the machine This may have an adverse effect on performance and the life of the machine Cleaning of the fan every month is recommended Contact your local Sony Sales Office Service Center for information on cleaning the fan 2 3 About the Data Backup Capacitor A large capacitor 1s installed on the CA 54CFA board in order to backup the memory storing the setup and other data in the MVE 9000 Leave the main power of the MVE 9000 turned on for an hour or longer in order to charge this capacitor The data is backed up for about a week when the cap
13. status LED Lit when the CPU DK module is inserted correctly to the parent board DI2 green F 3 RUN status LED Lit when the CPU DK module starts operating DI3 F 3 DI6 F 3 DI7 F 3 DI8 F 4 green STATUS1 to STATUS4 LED Used for maintenance purpose Only the STATUS1 LED is lit in normal operation DI4 green B 5 3 3 V Indicates the status of the VCC CORE and VCC 1 0 powers that are supplied to the CPU DK module lt Switch on the CPU DK module gt COM CPU 1 COM CPU 2 SW1 D 5 RESET switch Pressing this switch resets the CPU DK module Note In some machines in which the CPU DK module is installed the system reset may be activated SW2 C 5 MODE switch 8 pin DIP switch Used only for production in the assembly factory All switches are set to OFF for normal operation Default setting when shipped from the factory 1s all OFF MVE 9000 IM lt LED on the DIF 130 board gt PC card D1 A 1 DETECT A Lit when the socket A is inserted correctly D2 A 1 DETECT B Lit when the socket B is inserted correctly D3 A 1 3 3 V 3 3 V power supply status indication Lit when 3 3 V power is supplied D4 A 1 ACTIVE A Lit when the socket A is active D6 A 1 CD Card Detect status LED Lit when the DIF 130 board is inserted into the mother board correctly D7 A 1 GPO status LED GPO status indication lt Test terminal on the DIF 130
14. 2 check terminal 2 5 V 2 measuring terminal TP506 H 5 12 V check terminal 12 V measuring terminal TP601 A 1 CK clock for video signal terminal Used when checking the clock for video signal TP3801 H 1 DBG 3 A check terminal Used for design purpose TP3802 H 1 DBG 2 A check terminal Used for design purpose TP3803 H 1 DBG 1 A check terminal Used for design purpose TP3804 H 1 DBG 0 A check terminal Used for design purpose TP3901 H 6 DBG 3 B check terminal Used for design purpose TP3902 H 6 DBG 2 B check terminal Used for design purpose TP3903 H 6 DBG 1 B check terminal Used for design purpose TP3904 H 6 DBG 0 B check terminal Used for design purpose MVE 9000 IM lt LEDs on the CPU DR module gt G 2 G 5 Refer to lt LED on the CPU DR module gt in 1 CA 54CEFA Board lt Switches on the CPU DR module gt G 2 G 5 Refer to lt Switches on the CPU DR module gt in 1 CA 54CFA Board 3 VIF 28 board L_ TP301 E611 D603 C TP603 C E608 L_ TP3105 C TP3104 C TP3102 L_ TP3103 TP1001 E626 TP801 C_ E606 ND3401 ND3402 E607 TP3401 TP3404 TP3402 TP3403 3401 lt LED gt D601 A 3 12 V 12 V power supply status indication Lit when the 12 V power is supplied If this LED does not light the fuse may have blown D602 A 4 1 8 V 1 8 V power supply sta
15. 4 V S lt Open collector output gt GPI OUT 5 8 GPI OUT COM 1 8 Checks on Completion of Installation 1 8 1 On board Switches Setting and LED Functions The number shown in parentheses indicates the address on the circuit board 1 CA 54CFA board ci A E5 CPU DR Module MAIN CPU ND101 S902 ND102 31102 TP16 TP15 TP11 TP14 ND901 ND902 ND1101 ND1102 S104 S901 S1101 CN103 OO l DIF 130 CN503 CN703 PC CARD __ CN401 C CN1002 _ lt LED gt D4 A 1 3 3 V 3 3 V power supply status indication Lit when the 3 3 V power is supplied D5 A 2 12 V 12 V power supply status indication Lit when the 12 V power is supplied If this LED does not light the fuse may have blown D101 D102 D103 D104 A 4 ND101 A 3 ND102 A 4 MAIN CPU status LED Main CPU status indication CPU DK Du Module p COM CPU 1 A side Component side D409 A 2 RESET status LED System reset status indication Lit when S401 is pressed or the power voltage drops to 3 3 V D410 A 2 CPU RESET status LED CA 54CFA board reset status indication Lit when S402 is pressed or the power voltage drops to 3 3 V D601 A 2 REF EXT status LED REF IN signal presence absence status indication Lit when the REF sig
16. MVE 9000 IM 1 9 1 6 Matching Connectors and Cables Use the following connectors cables or equivalents when connecting cables to the unit Model name MVE 9000 MKE 9020M MKE 9021M Panel indication Connector name REF IN BNC 75 Q EXT IN 1 4 MONI OUT 1 4 REMOTE 1 4 D sub 9 pin Female GPI D sub 25 pin Female GPI2 DATA RJ 45 modular jack CTRL SWITCHER A B MDR 68 pin Female IN V1 V4 IN K1 K4 OUT V1 V4 OUT K1 K4 BNG 75 Q x1 The following crimp contact is required for the plug AWG 18 to 22 1 566 493 21 AWG 22 to 24 1 564 774 11 AWG 24 to 30 1 564 775 11 2 Conforms to the IEEE 802 3 Ethernet1OOBASE TX standards Matching connector and cable Name Sony part No BNC 75 Q BELDEN 8281 coaxial cable D sub 9 pin Male Connector 9 pin Male Junction Shell 9 pin D sub 25 pin Male Connector 25 pin Male Junction Shell 25 pin 1 560 651 00 1 561 749 00 1 560 904 11 1 563 377 11 Dedicated cable Supplied accessory of MKE 9020M BNC 75 Q BELDEN 8281 coaxial cable MVE 9000 IM 1 7 Input Output Signals of Connectors The input output signals of the connectors at the rear panel are as follows lt CONTROLLER gt indicates a controlling device lt DEVICE gt indicates a controlled device REMOTE 1 4 RS 422A D sub 9 pin Female lt DEVICE gt 1 EXT VIEW Pin No Signal Name Function y FG Frame ground TX Transmitted data 3 RX Receive
17. OY Cay x _ MVS 8400 8300 8200 Switcher Processor Pack VTR Audio Mixer ENEE Cross cable A Cable with BNC a It is recommended that the CTRL and DATA b Terminate with the supplied 75 Q terminators cones LAN networks be configured by connecting Terminators are supplied in the product separate Ethernet switches for each LAN package However it is also possible to make connections for both LANs on a single Ethernet switch 1 24 MVE 9000 IM Flow of Video Signals MKE 9021M Installed The figure below shows the flow of video signals in a MVS 8000 system MVE 9000 C DME Processor Pack V K OUT V K IN EXT IN gt 100 to 240 V AC power supply MONI OUT Reference video signal e gt Monitor Reference video signal POP ommo emo E omo oo 100 to 240 V AC power S supply H E AE SS E E 8 gt 100 to 240 V AC power SE supply PES PRIMARY INPUTS POO S 1 68 Gu OUTPUTS E 1 48 MONITOR OUTPUTS E Monitor lt US a MVS 8400 8300 8200 b Switcher Processor Pack gt 100 to 240 V AC power supply gt 100 to 240 V AC power supply Video input signal gt Video output signal Z Video key signal AC power supply a For the AC power cord of this unit refer to Section 1 2 Power c Terminate with the supplied 75 Q terminators Terminators are Supp
18. SON Y DME PROCESSOR PACK MVE 9000 C MULTI FORMAT DME PROCESSOR MVE 9000 HK PSU04 MKE 9020M MKE 9021M MKE 9040M INSTALLATION MANUAL 1st Edition Att ZOZ E JU HK EA Cs BERN TCOVIsAyY JM NIUE PRT HR BHR EATS ERB COCKE KFBWIZDEMATEMBVET ERIN RO PEARL HLT ASI EREDA CENS FES A WARNING This manual is intended for qualified service personnel only To reduce the risk of electric shock fire or injury do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Refer all servicing to qualified service personnel A WARNUNG Die Anleitung ist nur f r qualifiziertes Fachpersonal bestimmt Alle Wartungsarbeiten d rfen nur von qualifiziertem Fachpersonal ausgef hrt werden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten d rfen nur von Personen ausgef hrt werden die eine spezielle Bef higung dazu besitzen A AVERTISSEMENT Ce manual est destin uniquement aux personnes comp tentes en charge de l entretien Afin de r duire les risques de d charge lectrique d incendie ou de blessure n effectuer que les r parations indiqu es dans le mode d emploi moins d tre qualifi pour en effectuer d autres Pour toute r paration faire appel une personne comp tente uniquement MVE 9000 Serial
19. acitor 1s fully charged under normal operating tempera ture MVE 9000 IM COVA WIS NCSD SHO SESS EI HOES ET ors vicki CEE LO WHN FEE ETE EBRAAW CAV a7 EENT A Cea R ELET The material contained in this manual consists of information that is the property of Sony Corporation Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation Le mat riel contenu dans ce manuel consiste en informations qui sont la propri t de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des op rations ou entretiens de l quipement a moins d une permission crite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdr cklich die Vervielf ltigung jeglicher Teile dieser Anleitung oder den Gebrauch derselben f r irgendeinen anderen Zweck als die Bedienung oder Wartung der in dieser Anleitung beschriebenen Ausr stung ohne ausdr ckliche schriftliche Erlaubnis der Sony Corporation MVE 9000 IM Printed in Japan MVE 9000 C SY E sony Corporation 2003 4 08 3 790 017 01 B amp P Company 2003
20. board gt PC card E1 E 1 E2 A 1 E3 B 2 E4 C 2 GND terminal Use this terminal as the earth point for measuring the respective check terminals TP1 B 3 RST signal check terminal RST signal measuring terminal TP2 B 3 CLK signal check terminal CLK signal measuring terminal TP3 B 3 FRAME signal check terminal FRAME signal measuring terminal TP4 B 3 IRDY signal check terminal IRDY signal measuring terminal TP5 B 3 TRDY signal check terminal TRDY signal measuring terminal TP6 C 3 DEVSEL signal check terminal DEVSEL signal measuring terminal TP7 C 3 STOP signal check terminal STOP signal measuring terminal TP8 C 3 LOCK signal check terminal LOCK signal measuring terminal TP9 C 3 PERR signal check terminal PERR signal measuring terminal TP10 C 3 SERR signal check terminal SERR signal measuring terminal TP11 B 1 PAR signal check terminal PAR signal measuring terminal TP12 D 1 INT signal check terminal INT signal measuring terminal TP13 D 1 CBE3 signal check terminal CBE3 signal measuring terminal TP14 C 1 CBE2 signal check terminal CBE2 signal measuring terminal TP15 B 1 CBE1 signal check terminal CBE1 signal measuring terminal TP16 B 1 CBEO signal check terminal CBEO signal measuring terminal lt LED on the SG 272 board gt D100 B 1 REF OK status LED Lit while V sync of the reference input is detected D101
21. cal sync signal check terminal Use this terminal to check the VD signal supplied from mother board TP3401 A 9 TP3402 A 9 TP3403 A 10 TP3404 A 9 DBG3 0 check terminal Used for design purpose lt LEDs on the CPU DR module gt C 11 Refer to lt LED on the CPU DR module gt in 1 CA 54CFA Board lt Switches on the CPU DR module gt C 11 Refer to lt Switches on the CPU DR module gt in 1 CA 54CFA Board 1 21 1 9 System Connection Connection Example of the MVS 8000 System MKE 9020M Installed Reference video signal D Ethernet switch Ethernet switch MVE 9000 C DME Processor Pack BVE 9100 Editing Control System Reference video signal D REMOTE 1 e gt CO PERIPH E DATA MKS 8010 System 8 Control Unit S Reference video i S signal gt 0 J BKS R Series V o 1 f J EE 00000000000000000 00000000000000000 P00000000000000000 0000000000000000 0000000000000000 0000000000000000 0000000000000000 O Reference video signal pJ q00000000000000000000 OO OO N AN O a OY Noy x _ MVS 8400 8300 8200 Switcher Processor Pack VTR Audio Mixer EE Cross cable eee eee Cable with BNC a It is recommended that the
22. ce Conforms to RS 232C CN4001 A 9 ISP common connector Used only for production in the assembly factory Used for program writing into the JTAG device with ISP lt TEST terminals gt E601 H 4 E604 C 9 E605 N 2 E606 C 7 E607 A 11 E608 B 5 E609 L 4 E610 N 6 E611 E 4 E622 F 7 E623 A 2 E625 J 6 E626 F 7 E627 F 10 GND terminals Use these terminals as the earth point for measuring the respective check terminals TP201 C 3 TP603 A 5 1 5 V check terminal 1 5 V measuring terminal TP301 E 3 TP602 A 5 1 8 V check terminal 1 8 V measuring terminal TP401 G 3 TP604 A 4 2 5 V check terminal 2 5 V measuring terminal TP501 J 3 TP605 A 4 3 3 V check terminal 3 3 V measuring terminal TP601 A 4 12 V check terminal 12 V measuring terminal MVE 9000 IM TP701 G 7 TP801 G 7 TP901 E 7 TP1001 E 7 TP1101 K 6 TP1201 K 6 TP1301 J 6 TP1401 H 6 TP1501 N 6 TP1601 N 6 TP1701 M 6 TP1801 M 6 ERR terminal Used for design purpose TP3102 C 6 CKX control timing signal check terminal Use this terminal to check the CKX signal supplied from mother board TP3103 C 6 FD signal check terminal Use this terminal to check the FD signal supplied from mother board TP3104 C 6 HD horizontal sync signal check terminal Use this terminal to check the HD signal supplied from mother board TP3105 C 5 VD verti
23. d data 7 GND Ground S 8 No Connection A GND Ground 7 TX Transmitted data E RX Received data E No Connection 1 Editing control unit such as BVE 9100 EDITOR DATA CTRL 100BASE TX RJ 45 8 pin 1 8 mj EXT VIEW Pin No Signal Name Function 4 TE Transmitted data o pe Transmitted data 3 RX Received data A ei No Connection 5 No Connection 6 RX Received data 7 No Connection 8 No Connection MVE 9000 IM GPI GPI2 D sub 25 pin Female INPUT x 8 TTL OUTPUT x 4 relay contacts 30 V 0 1 A resistive load OUTPUT x 4 open collector 30 V rated voltage 1 1 O 0 0 0010 6 60 06 O G0 6 O A OE A R EXT VIEW Pin No Signal Name Function 1 GND Ground 2 GND Ground 3 GPI IN 2 General purpose input 4 GPI IN A 5 GPI IN 6 6 GPI IN 8 7 GPI OUT 1B General purpose relay output Din 8 GPI OUT 2B 9 GPI OUT 3B 10 GPI OUT 4B 11 GPI OUT 6 General purpose open collector 12 GPI OUT 8 output 13 GPI OUT COM Ground for open collector output 14 GND Ground 15 GPI IN 1 General purpose input 16 GPI IN 3 17 GPI IN 5 18 GPI IN 7 19 GPI OUT 1A General purpose relay output Al 20 GPI OUT 2A 21 GPI OUT 3A 22 GPI OUT 4A 23 GPI OUT 5 General purpose open collector 24 GPI OUT 7 output 25 GPI OUT COM Ground for open collector output A and B of the same number constitute a pair of relay contacts lt Relay gt GPI OUT n B O GPIOUTnA n 1
24. en the DLL Delay Locked Loop of the FPGA is locked If this LED does not light the FPGA may be defective D3703 H 2 RCB DONE status LED Lit when configuration of FPGA is complete D3704 H 2 SYSTEM status LED Lit when configuration is complete and FPGA reset is also complete If the LED does not light the FPGA may be defective D3705 H 5 CN EXIST status LED CN 2357 board presence absence status indication Lit on the DVP 24A board that is installed in the same slot of CN 2357 board when CN 2357 board is present D3706 H 6 CN POWER status LED The CN 2357 board power status indication Lit on the DVP 24A board that is installed in the same slot of CN 2357 board while the power supply inside the CN 2357 board is activated D3801 H 1 DBG 7 A status LED Used for design purpose D3802 H 1 DBG 6 A status LED Used for design purpose D3803 H 1 DBG 5 A status LED Used for design purpose D3804 H 1 DBG 4 A status LED Used for design purpose D3901 H 6 DBG 7 B status LED Used for design purpose D3902 H 6 DBG 6 B status LED Used for design purpose D3903 H 7 DBG 5 B status LED Used for design purpose D3904 H 7 DBG 4 B status LED Used for design purpose ND3801 H 2 ND3802 H 2 STATUS A LED DVP 24A board CPU_A status indication ND3901 H 6 ND3902 H 6 STATUS B LED DVP 24A board CPU_B status indication lt Switch gt 3501 H 3 CPU A CONFIG switch
25. in a 19 inch standard rack To mount the MVE 9000 in a rack use the specified rack mount kit and follow the procedure described below Specified rack mount kit RMM 10 If a rack mount kit other than the specified one is used the unit may not be correctly install in a 19 inch standard rack Parts of the RMM 10 e Rack tools 2 pcs Right rack mount adaptor 1 pc Left rack mount adaptor 1 pc e Rack tool attaching screws 6 pcs B4 X 6 7 682 560 09 e Rack tool attaching screws 6 pcs B4 X 10 7 682 560 10 1 Precautions for rack mounting To prevent the rack from falling or moving fix the rack on a flat and steady floor using bolts or other fixings If the rack falls due to the weight of the equipment it may cause death or injury e Be sure to use the specified rack mount kit If not injury may result and the equipment may fall due to insufficient strength After rack mounting be sure to tighten the screws on the rack angle and fix the unit in the rack If the screws on the rack angle are not tightened the unit may slip from the rack and fall causing injury When mounting the unit in the rack note the following Be sure to mount in the rack with two persons or more Be careful not to catch your fingers or hands in the rack mount rail or others e Mount in the rack in a stable position If several units are mounted in a rack it is recommended that a ventilation fan is installed to prevent temperature
26. ly in this manual supplied in the product package b For the AC power cord of the MVS 8000 refer to Section 1 2 Power Supply in the MVS 8400 8300 8200 Installation Manual MVE 9000 IM 1 25 Section 2 Service Overview N 1 Troubleshooting The main power cannot be turned on Indicator does not light green Flow1 The main power of the MVE 9000 cannot be turned on Indicator does not light green YES Is the POWER switch A of the MVE 9000 turned ON Set it to ON Z O YES NO Is the power cord of the MVE 9000 connected correctly Connect it correctly YES The power supply unit is probably defective The monitor picture is not displayed correctly Flow2 The monitor picture is not displayed correctly even though the main power of the MVE 9000 is turned on YES Are the plug in boards inserted into their correct NO_ Insert the plug in boards into the correct slots slots Refer to the MVE 9000 C Maintenance Manual YES Are the option boards inserted into their correct NO Insert the option boards into the correct slots slots respectively Refer to Section 1 4 YES NO Connect the input and output cables and equipment Are the input and output cables connected correctly correctly YES NO Install the software correctly Is the software installed correctly d Refer to the User s Guide YES NO Start up the system in the Factory Set mode and Is the system
27. nal is input to the REF IN connector Not lit when the REF signal is not input to the REF IN connector MVE 9000 IM D602 A 2 PLL LOCK status LED REF IN signal format status indication Lit when the REF IN signal matches with the switcher format setup D701 A 2 SBUS RX status LED S BUS receive status indication Lit while the data receive is in progress D704 A 2 SBUS TX status LED S BUS send status indication Lit while the data send is in progress D901 A 4 D902 D903 D904 A 5 COM CPU 1 status LED COM CPU status indication D1001 A 2 COM1 100 status LED COM CPU 1 Ethernet communication speed status indication Lit 100 Mb s Not lit 10 Mb s D1002 A 2 COM1 ACT status LED COM CPU 1 Ethernet communication status indication Lit while data send or receive is in progress D1101 D1102 D1103 D1104 A 5 COM CPU 2 status LED COM CPU 2 status indication D1201 A 2 COM2 ACT status LED COM CPU 2 Ethernet communication status indication Lit while data send or receive is in progress D1202 A 2 COM2 100 status LED COM CPU 2 Ethernet communication speed status indication Lit 100 Mb s Not lit 10 Mb s D1303 A 2 5 V 5 V power supply status indication Lit when the 5 V power 1s supplied ND901 ND902 A 4 COM CPU 1 status LED COM CPU status indication ND1101 ND1102 A 4 COM CPU 2 status LED COM CPU 2 status indication MVE 9000 IM lt Switch gt
28. normally operate The MVE 9000 contains the single power supply unit as the standard configuration A maximum of two power supply units may be installed When starting up the MVE 9000 be sure to turn on the power of one or more power supply units 1 1 1 2 2 Recommended Power Cord This unit does not come with a power cord To get a power cord please contact your local Sony Sales Office Service Center WARNING e Use the approved Power Cord 3 core mains lead Appliance Connector Plug with earthing contacts that conforms to the safety regulations of each country if applicable Use the Power Cord 3 core mains lead Appliance Connector Plug conforming to the proper ratings Volt age Ampere If you have questions on the use of the above Power Cord Appliance Connector Plug please contact your local Sony Sales Office Service Center WARNING e Never use an injured power cord e Plugging the power cord in the AC inlet push as far as it will go For customers in the U S A and Canada Q Power cord 125 V 10 A 2 4 m A 1 557 377 11 AC inlet For customers in the all European countries Q Power cord 250 V 10 A 2 4 m A 1 782 929 21 gt b MVE 9000 IM 3 Installation Space External dimensions LM GC Saa 29000900009 ROS OOOO tte tt OSOS OOOO 70000000000000 OS JO Wel A 006 Unit mm MVE 9000 IM 1 4 Installing the Options
29. rise inside the rack 2 Rack mounting procedure This section describes the rack mounting procedure using the RMM 10 rack mount kit Tighten the screws to the following torque Tightening torque 120 X 107 Nem 12 2 kgf cm 1 Attach the rack tool to the side of the equipment using the specified six screws Use B4 X 6 screws Rack tool B4 x6 NE Rack tool BA x 6 2 Loosen the screws on the rear of the right and left adaptors and adjust the length of the adaptor according to the depth of the rack The illustration below shows the left adaptor Adaptor Portion of the rail Maximum depth of adaptor 750 mm Minimum depth of adaptor 595 mm MVE 9000 IM 3 Attach the right and left adaptors to the rack complete 7 Fix the rack angles in the rack using the specified ly using the specified six screws screws The illustration below shows the left adaptor Q AS Rack angle O B4 x 10 Unit mm 4 Tighten the screws B4 X 6 two screws each on the right and left for adjusting the length of the adaptor completely the screws that were loosened in step 2 5 Align the groove of the rack tool at the side of the equipment with the rail and slide the equipment to the rear The rack tools are hooked on the rails as shown below Rack angle 8 Install the front panel to the equipment Rack tool Rack tool 6 Remove the front panel Refer to Section 1 4 1
30. rpose of this manual Related manuals Contents Trademark Manual Structure This manual is the installation manual of DME Processor Pack MVE 9000 C and their optional boards and units This manual is intended for use by trained system and service engineers and describes the information on installing the MVE 9000 C system The following manuals are prepared for MVE 9000 C and their optional boards and units e Operation Manual Supplied with MVE 9000 C This manual describes the application and operation of MVE 9000 C system e Maintenance Manual Available on request This manual describes the detailed service information If this manual is required please contact your local Sony Sales Office Service Center This manual is organized by following sections Section 1 Installation This section describes the operating environment power supply installation space installation of optional boards and units rack mounting connectors input and output signals of connectors checking upon completion of installation and system configuration Section 2 Service Overview This section describes the troubleshooting and periodic inspection and maintenance Registered trademark used in this manual is follows Ethernet is a registered trademark of Xerox Corporation MVE 9000 IM Section 1 Installation 1 1 Operating Environment 5 C to 40 C Performance guaranteed temperature 10 C to 35 C 10 to 90 Opera
31. s switch resets the system while maintaining this unit through the COM CPU 2 control terminal 1102 A 4 Modes setting switch for the COM CPU 2 Sets the modes of the COM CPU 2 Default setting when shipped from the factory is all OFF 1 13 lt Connector gt CN103 A 4 TERMINAL pin This pin is connected to the main CPU control terminal and used during maintenance Conforms to RS 232C CN401 A 5 TERMINAL pin This pin is connected to the IEEE1394 control terminal and used during maintenance Conforms to IEEE1394 CN503 A 5 TERMINAL pin This pin is connected to the COM CPU 1 control terminal and used during maintenance Conforms to RS 232C CN703 A 5 TERMINAL pin This pin is connected to the COM CPU 2 control terminal and used during maintenance Conforms to RS 232C CN1002 A 5 TERMINAL pin This pin is connected to the S BUS CPU control terminal and used during maintenance Conforms to RS 232C CN1003 A 3 ISP common connector Used only for production in the assembly factory Used for program writing into the JTAG device with ISP lt TEST terminal gt E1 E 5 E2 E 1 E3 C 3 E4 A 5 E5 A 1 GND terminal Use this terminal as the earth point for measuring the respective check terminals TP1 A 1 3 3 V check terminal 3 3 V measuring terminal TP23 B 1 12 V check terminal 12 V measuring terminal TP1301 A 1 5 V check terminal 5 V measuring terminal
32. ting guaranteed temperature Operating humidity relative humidity 20 C to 60 C Mass when all options are installed Approx 27 kg Storage temperature Prohibited locations for installation e Areas where the unit will be exposed do direct sunlight or any other strong lights e Dusty areas Areas subject to vibration Areas with strong electric or magnetic fields Areas near heat sources Areas subject to electrical noise Areas subject where is subjected to static electricity Ventilation The inside of the MVE 9000 C is cooled by a fan both sides The power supply can be damaged if the exhaust vent both sides and air intake front panel are blocked or the fan is stopped Therefore leave a blank space of more than 10 cm in the front and both sides of the MVE 9000 C MVE 9000 IM 1 2 Power Supply 1 2 1 Power Specifications A switching regulator is used for the power supply of this unit The voltage within the range of 100 V to 240 V can be used without changing the supply voltage Power requirements AC 100 to 240 V 10 Power frequency 50 60 Hz Current consumption when all options are installed 6 0to2 5A As the inrush current at turn on is a maximum 110 A at 100 V 220 A at 240 V the capacity of the AC power source must be commensurate with this load If the capacity of the AC power is not adequately large the AC power source braker will operate or the unit will ab
33. tus indication Lit when the 1 8 V power is supplied D603 A 5 1 5 V 1 5 V power supply status indication Lit when the 1 5 V power is supplied D604 A 4 2 5 V 2 5 V power supply status indication Lit when the 2 5 V power is supplied 1 20 L_ TP401 L_ TP501 E601 TP1401 E625 TP1201 TP1801 E610 TP1601 EL H AJA ar A A TP1301 TP1101 TP1701 TP1501 TI tP701 A side Component side D605 A 4 3 3 V 3 3 V power supply status indication Lit when the 3 3 V power 1s supplied D3301 A 10 BOOT DONE status LED Lit when IC3301 starts up D3302 A 9 DLKD status LED Lit when the DLL of the FPGA is locked If this LED does not light the FPGA may be defective D3303 A 10 RCB DONE status LED Lit when configuration of FPGA is complete D3304 A 9 SYSTEM status LED Lit when configuration is complete and FPGA reset is also complete If the LED does not light the FPGA may be defective MVE 9000 IM D3401 D3402 D3403 D3404 A 10 DBG7 4 status LED Used for design purpose ND3401 A 10 ND3402 A 11 STATUS LED VIF 28 board CPU status indication lt Switches gt 3201 A 8 CPU CONFIG switch Used for maintenance purpose S3401 A 10 SETUP switch Used for maintenance purpose lt Connectors gt CN3202 A 7 USB terminal Used for debugging CN3203 A 8 TERMINAL pin This pin is connected to the sub CPU control terminal and used during maintenan