Contents

1. A SIDE VIEW 2 5 cm Maintenance instructions e Clean lint screen after each cycle e Keep dryer area clear and free from combustible materials gasoline and other flammable vapors and liquids e Do not obstruct the flow of Combustion and ventilation air Moving the dryer to a new location Slide dryer onto cardboard or hardboard before moving across floor to avoid damaging floor covering Gas dryer models e Disconnect electrical cord Tape securely to dryer e Shut off the gas supply valves in the gas supply line e Disconnect gas pipe and fittings from dryer and cap gas supply line Tape end of dryer gas pipe CORPORATION Prepared by Whirlpool Corporation Benton Harbor Michigan 49022 Electric dryer models e Shut of electrical supply to dryer e Disconnect the power supply cord or cable from the dryer terminal block All models e Make sure leveling legs are secure in dryer base e Tape drum to front panel e Tape dryer door lint screen and end of gas pipe Before the appliance is removed from service or discarded remove the door to the dryer compartment If dryer does not operate properly Check the following to be sure that 1 Electric supply is connected 2 Circuit breakers are not tripped or house fuses blown Door is closed Controls are set in a running or ON position Start button has been pushed firmly For gas dryers check that gas suppl
2. installation Instructions IMPORTANT Read and save these instructions IMPORTANT Installer Leave Installation Instructions wi e owner Owner Keep Installation Instructions for f Ce Save installation Instructions for local electrical insoector s use www whirlpool com COMMERCIAL ELECTRONIC DRYER 120 volt 60 Hz 120 240 volt 60 Hz Part No 8316557 Before you start Your safety and the safety of others are very important We have provided many important safety message in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance A WARNING Explosion Hazard Keep flammable materials and vapors such as gasoline away from dryer Place dryer at least 18 inches 45 8 cm above the floor for a garage installation Failure to do so can result in death explosion or f
3. ANSI NFPA 70 latest edition and all local codes and ordinances Copies of the standards listed above may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 Now Start amp WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury With dryer in laundry area fuse disconnect a a box exhaust vent 30 amp outlet 1 m ake tape off front corners of dryer Open dryer and remove the literature and parts packages Wipe the interior of the drum thoroughly with a damp cloth 2 m lake two of the cardboard corners from the carton and place them on the floor in back of the dryer Firmly grasp the body of the dryer and genily lay it on its back on the cardboard corners 3 a With one of the legs in hand check the ridges for a diamond marking That s how far the leg is supposed to go into the hole 4 m Start to screw the leveling legs into the holes by hand Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs Use a 1 inch wrench or socket wrench to finish turning the legs until you reach the diamond mark Now stand the dryer up Slide dryer onto cardboard or hardboard before moving across floor to avoid damaging floor covering 5 m Move dryer close to final position Remove cardboard or hardboard f
4. recommended in the user maintenance instructions or in published user repair instructions that you understand and have the skills to carry out 9 Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product 10 Do not use heat to dry articles containing foam rubber or similarly textured rubber like materials 11 Clean lint screen before or after each load 12 Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint dust and dirt 13 The interior of the appliance and exhaust duct should be cleaned periodically by qualified service personnel 14 Do not place items exposed to cooking oils in your dryer Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire SAVE THESE INSTRUCTIONS Post this warning in a prominent location FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances Exhaust requirements amp WARNING Vj Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to do so can result in death or fire Do not use non metal flexible vent metal vent that is smaller than four inches in diameter or exhaust hoods with magnetic latches The dryer must be exhausted outdoors Do not e
5. Start With dryer in laundry area amp WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury 3 prong ground type outlet exhaust duct gas shutoff valve 1 m ake tape off front corners of dryer Open dryer and remove the literature and parts packages Wipe the interior of the drum thoroughly with a damp cloth 2 m lake two of the cardboard corners from the carton and place them on the floor in back of the dryer Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners 3 a With one of the legs in hand check the ridges for a diamond marking That s how far the leg is supposed to go into the hole 4 m Start to screw the leveling legs into the holes by hand Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs Use a 1 inch wrench or socket wrench to finish turning the legs until you reach the diamond mark Now stand the dryer up Slide dryer onto cardboard or hardboard before moving across floor to avoid damaging floor covering Page 6 5 m Move dryer close to final position Remove cardboard or hardboard from under dryer 6 Remove red cap from gas pipe Carefully move dryer into final position Place level on top of the dryer first side to side then front to back If the dryer is not level adjust the legs of the dryer up
6. or down until the dryer is level T m Connect gas supply to dryer Use pipe joint compound resistant to the action of L P gas for gas connections If flexible metal tubing is used be certain there are no kinks If necessary for service open the toe panel use a putty knife to press on the toe panel lock located at the center top of the toe panel Pull downward on the toe panel to open Toe panel is hinged at the bottom 8 Open the shutoff valve in the gas supply line Use a non corrosive leak detection fluid to check for leaks Bubbles around connections will indicate a leak NEVER TEST FOR GAS LEAKS WITH A FLAME If a leak appears shut off gas valve controls and adjust connections Then check connections again Close toe panel All connections must be wrench tightened 1 O m lo exhaust dryer see Exhaust requirements Pages 3 4 Connect exhaust vent system to dryer exhaust outlet and exhaust hood using 4 10 2 cm clamps Use caulking to seal exterior wall opening around exhaust hood 1 1 m Carefully move dryer into final position Place level on top of the dryer first side to side then front to back If the dryer is not level adjust the legs of the dryer up or down until the dryer is level 1 2 Plug power supply cord into grounded outlet 1 3 m Check dryer operation some accumulated time may be on the timer due to factory testing Pull timer set button left Operating time will accumulate per
7. a three wire receptacle of NEMA Type 10 30R DIRECT WIRE Preparing the wire Three wire with ground wire Bare wire cut short Wire is not used Dryer is grounded through direct wire cable 3 4 1 9 cm 1 U L listed strain 1 2 5 cm of wires to lt stripped of disconnect insulation 10 gauge 3 wire or NEUTRAL wire 10 gauge 3 wire with white or center ground wire Romex 3 1 2 8 9 cm Strip 3 1 2 8 9 cm of outer covering from end of cable Strip insulation back 1 2 5 cm If using 3 wire cable with ground wire cut bare wire even with outer covering Shape ends of wires into a hook Page 10 Three wire receptacle Where local codes permit connecting cabinet ground conductor to neutral wire 4 Loosen or remove center terminal block screw 5 Connect the neutral wire white EN or center of power supply cord to gt Q the center silver colored terminal Wi screw of the terminal block Tighten screw 6 Connect the other wires to outer terminal block screws Tighten screws 7 Tighten strain relief screws 8 Insert tab of terminal block cover into slot of dryer rear panel secure cover with hold down screw Where local codes permit connecting cabinet ground conductor to neutral wire 4 Loosen or remove center terminal block screw 5 Place the hooked end of the neutral wire white or center of power supply cable under the center screw of the terminal bl
8. an Gas conversion kit part numbers are listed on the gas valve burner base m Provide a rigid gas supply line of 1 2 inch IPS pipe to the dryer location If the total length of the supply line is more than 20 feet 6 1 m larger pipe will be needed For L P gas usage 3 8 inch approved copper tubing may be used Pipe joint compounds suitable for use with L P gas should be used shutoff valve open position to dryer Qa ee F The supply line shall be equipped with a shutoff valve installed within 6 ft 1 8 m of dryer in accordance with the National Fuel Gas Code ANSI Z223 1 latest edition This valve should be located in the same room as the dryer and should be in a location that allows ease of opening and closing Do Not block access to the shutoff valve G a f the dryer is installed in a confined area such as a bathroom or closet provision must be made for enough air for combustion and ventilation Check governing codes and ordinances or refer to the section of this instruction covering recessed and closet installations a f local codes and ordinances permit it is recommended that new flexible metal tubing design certified by the AGA or CSA be used for connecting the dryer to the gas supply line Ihe gas feed pipe which extends through the lower rear of the dryer is provided with 3 8 inch metal pipe thread I If rigid pipe is used as a gas supply line a combina
9. for periodically cleaning of the exhaust system Page 4 An exhaust hood should cap the outside end of the main vent to prevent exhausted air from returning to the dryers If an exhaust hood cannot be used the outside end of the main vent should have a sweep elbow directed downward If the main vent travels vertically through the roof rather than through the wall install 180 sweep elbow on the end of vent at least 2 feet 61 cm above the highest part of the building The opening wall or roof shall have a diameter 1 2 inch 1 3 cm larger than the exhaust vent diameter The exhaust vent should be centered in the opening Gas requirements AWARNING Explosion Hazard Use a new AGA or CSA exhaust approved gas supply line hood g lt wall Install a shut off valve elbow Y horizontal vent Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 13 33 cm water column Examples of a qualified person include sweep licensed heating personnel main exhaust vent 180 2 ft 61 cm K elbow authorized gas company mne anaye ersonnel and authorized highest point of p b 7 building service personnel main collector i vent Failure to do so can result in death explosion or fire vertical vent roof OBSERVE ALL GOVERNING CODES AND ORDINANCES Do Not install screening or cap over end of vent A The instal
10. hood is preferred However a 2 1 2 inch 6 4 cm outlet exhaust hood may be used A 2 1 2 inch 6 4 cm outlet creates greater back pressure than other hood types For permanent installation a stationary exhaust system is required A main exhaust vent can be used for exhausting a group of dryers Main exhaust vent should be sized to remove 200 CFM of air per dryer Large capacity lint screens of proper design may be used in the main exhaust vent if checked and cleaned frequently The room where the dryers are located should have make up air equal to or greater than the CFM of all The dryers in the room Back draft Damper Kits Part No 3391910 are available from your Whirlpool dealer and should be installed in each dryer s exhaust vent to prevent exhausted air from returning into the dryers and to keep the exhaust in balance within the main exhaust vent Unobstructed air openings are required Each exhaust vent should enter the main vent at an angle pointing in the direction of the airflow Vents entering from the opposite side should be staggered to reduce the exhausted air from interfering with the other vents The maximum angle of each vent entering the main vent should be no more than 30 Keep air openings free of dry cleaning fluid fumes Fumes create acids which when drawn through the dryer heating units can damage dryers and loads being dried A clean out cover should be located on the main exhaust vent
11. ing the wire green with yellow stripes from 3 1 2 8 9 cm gt external ground connector screw Fasten under center silver colored 3 4 U L 1 2 5 cm dTa 3 a oe terminal block screw relief i iS sia o 6 Connect the ground wire bare disconnect of the power supply cable to the box t NEUTRAL wire external ground conductor screw white or center Tighten screw 7 Place the hooked end of the neutral wire white or center of 10 gauge 3 wire bare ground power supply cable under the center with ground wire lls screw of terminal block hook facing Romex right Squeeze hook end together Tighten screw lt 5 12 7 cm 8 Place the hooked enas of the other power supply cable wires Strio 5 12 7 cm of outer under the outer terminal block screws covering from end of Shape hook facing right Squeeze hooked cable Leave bare ground ends ends together Tighten screws wire at 5 inches Cut 1 1 2 a 97 a 3 8 cm from 3 remaining lighten strain relief screws wires Strip insulation back Ae 10 1 inch 2 5 cm OOK Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Page 9 Three wire connection POWER SUPPLY CORD spade terminals with upturned ends ring terminals This blade connected NEUTRAL 3 4 U L listed NEUTRAL strain relief white or center Three wire power supply cord must have three No 10 copper wires and match
12. ire If installing a GAS dryer Post this warning in a prominent location It is recommended that the operator oost in a prominent location instructions for the customer s use in the event the customer smells gas This information should be obtained from your local gas supplier Page 2 DANGER You can be killed or seriously injured if you don t immediately follow instructions amp WARNING You can be killed or seriously injured if you don t follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed e Do nottouch any electrical switch do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions o If you cannot reach your gas supplier call the fire department Installation and service must be done by a qualified installer service agency or the gas supplier It is your responsibility to Observe all governing codes and ordinances Check code requirements Some codes limit or do not permit installation of clothes dryers in garages closets mobile homes or sleeping quarters Contact your local building inspector Comply with the installation specifications and dimensions Consider soacing requirements for companion app
13. ker is recommended It is recommended that a separate Circuit serving only this appliance be provided If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Recommended ground method The dryer when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 GROUNDING INSTRUCTIONS This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric Current The power supply cord plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipoment grounding conductor can result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician 3 prong ground type outlet 3 prong ground plug Z ground supply cord se Copies of the standards listed above may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 Page 5 Now
14. lation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 installation codes B m Ihe design of this dryer has been certified by the CSA International for use at altitudes up to 10 000 feet 3048 m above sea level at the B T U rating indicated on the model serial plate Burner input adjustments are not required when the dryer is operated up to this elevation When installed above 10 000 feet 3048 m a four percent 4 reduction of the burner B T U rating shown on the model serial plate is required for each 1 000 foot 805 m increase in elevation For assistance when converting to other gas types and or installing above 10 000 feet 3048 m elevation contact your local service company C m Check that dryer is equipped with the correct burner for the particular type of gas used Burner information can be found on the serial rating plate in the door well of the appliance If this information does not agree with the type of gas available see your dealer D m his dryer is equipped for use with NATURAL GAS It is certified by CSA International for manufactured mixed and L P oropane and butane gases with appropriate conversion No attempt shall be made to convert the appliance from the gas specified on the serial rating plate for use with a different gas without consulting the serving gas supplier Conversion must be done by a qualified service technici
15. liances Make sure you have everything necessary for proper installation Properly install dryer Contact a qualified installer to insure that the electrical and gas installations meet all national and local codes and ordinances Exhaust to outdoors Dryer must be exhausted outdoors to prevent exposure to harmful substances in the gas fuels Note The dryer must not be installed in an area where it will be exposed to water and or weather IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electric shock or injury to persons when using your appliance follow basic precautions including the following 1 Read all instructions before using the appliance 2 Donot dry articles that have been previously cleaned in washed in soaked in or spotted with gasoline dry cleaning solvents or other flammable or explosive substances as they give off vapours that could ignite or explode 3 Do not allow children to play on or in the appliance Close supervision of children is necessary when the appliance is used near children 4 Before the appliance is removed from service or discarded remove the door to the drying compartment 5 Donot reach into the appliance if the drum is moving 6 Do not install or store this appliance where it will be exposed to the weather 7 Do not tamper with controls 8 Do not repair or replace any part of the appliance or attempt any servicing unless specifically
16. n relief screws just enough to hold the two clamp sections together Install power supply cord cable through the strain relief Complete installation following instructions for your type of connection e Four wire recommended method e Three wire if four wire is not available Four wire connection POWER SUPPLY CORD 4 Remove center terminal block SCrew F 5 Remove appliance ground wire spade terminals with Shea Ha aed alls from upturned ends external ground connector screw Fasten under center silver colored terminal block screw 6 Connect ground wire green of NEUTRAL 2 4 U L listed NEUTRAL white power supply cord to external strain relief ground conductor screw Tighten screw 7 Connect neutral wire white or center of power supply cord under ground prong ground wire eee center screw of the terminal block green va Tighten screw ring terminals 8 Connect the other wires to outer Four wire power supply cord must have terminal block screws Tighten screws four No 10 copper wires and match a four wire receptacle of NEMA Type 9 Tighten strain relief screws 14 30R The fourth wire ground conductor must be Identified with a 10 Insert tab of terminal block cover green cover and the neutral into slot of the dryer rear panel Secure conductor by a white cover cover with hold down screw DIRECT WIRE 4 Remove center terminal block screw a eee 5 Remove appliance ground wire Prepar
17. n screw 6 Connect the other wires to outer T m O exhaust dryer see Exhaust requirements Pages 3 4 Connect exhaust vent to dryer exhaust outlet and exhaust hood using 4 10 2 cm clamps Use caulking to seal exterior wall opening around exhaust hood 8 Carefully move dryer into final position Place level on top of the dryer first side to side then front to back If the dryer is not level adjust the legs of the dryer up or down until the dryer is level Plug power supply cord into grounded outlet or connect direct wire to power supply Turn power supply on terminal block screws Tighten screws 7 Tighten strain relief screws 8 Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw 1 O m Check dryer operation some accumulated time may be on the timer due to factory testing Pull timer set button left Operating time will accumulate per number of depressions and type of timing cam used Push START RESTART button Using a full heat cycle not the air cycle let the dryer run for at least five minutes Note Dryer door must be closed for dryer to operate When door is open dryer stops but timer continues to run To restart dryer close door and push START RESTART button 1 1 m If drying time is too long make sure lint screen is clean 1 2 m Now start the dryer and allow it to complete a full heat cycle not air cycle to make sure it i
18. number of depressions and type of timing cam used Push START RESTART button Using a full heat cycle not the air cycle let the dryer run for at least five minutes Note Dryer door must be closed for dryer to operate When door is open dryer stops but timer continues to run To restart dryer close door and push START RESTART button 1 4 a If the burner does not ignite and you can feel no heat inside the dryer shut off dryer for five minutes Check that all supply valve controls are in ON position and that the electrical cord is plugged in Repeat five minute test 1 5 m If drying time is too long make sure lint screen is clean Electric Dryer Electrical requirements If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Important Observe all governing codes and ordinances A four wire or three wire single ohase 120 240 volt 60 Hz AC only electrical supply or four wire or three wire 120 208 volt if soecified on the model serial rating plate is required on a separate 30 ampere circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Recommended ground method It is The personal responsibility and obligation of the customer to contact a qualified electrician to assure that the electrical installation is adequate and in conformance with the National Electrical Code
19. ock hook facing right Squeeze hooked end together Tighten screw 6 Place the hooked ends of the other power supply cable wires under the outer terminal block screws hook facing right Squeeze hooked ends together Tighten SCrews 7 Tighten strain relief screws AIF W 8 Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Three wire connection DIRECT WIRE OR POWER SUPPLY CORD Three wire power supply cord must have three No 10 copper wires and match a three wire receptacle of NEMA Type 10 30R Direct wire power supply cable must be prepared as shown in Preparing the wire of the three wire connection direct wire steps above If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Three wire receptacle Where local codes Do Not permit connecting cabinet ground conductor to neutral wire 9 After reattaching the terminal cover connect a separate copper 4 Remove center terminal block ground wire from the external screw ground connector screw to an adequate ground 5 Remove the appliance harness ground wire green with yellow stripes from the external ground connector screw Connect appliance harness ground wire and the neutral wire white or center of the power supply cord cable under the center silver colored terminal block screw Tighte
20. rom under dryer Page 7 6 a Make electrical connection This dryer is manufactured with the cabinet ground conductor connected to the NEUTRAL center of the wiring harness at the terminal block If local codes do NOT permit this type of connection use Four wire connection instructions For a grounded cord connected appliance GROUNDING INSTRUCTIONS This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current If using a power supply cord the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician For a permanently connected appliance GROUNDING INSTRUCTIONS This appliance must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Page 8 Power supply cord Use a ne
21. s working properly Page 11 Recessed area and closet installation instructions This dryer may be installed in a recessed area or closet For recessed area and closet installations minimum clearances can be found on the serial tag on the dryer The installation spacing is in inches and is minimum allowable Additional spacing should be considered for ease of installation servicing and compliance with local codes and ordinances If closet door is installed the minimum unobstructed air openings in top and bottom is required Louvered doors with equivalent air openings are acceptable Companion appliance spacing should be considered The dryer must be exhausted outdoors No other fuel burning appliance may be installed in the same closet Minimum Installation Clearances 14 35 6 cm max Closet door __ 0 0 cm lt 2 5 cm Recessed Closet front view side view Closet door Closet front view Additional clearances for wall door and floor moldings may be required or if external exhaust elbow is used Opening is minimum for closet door Louvered door with equivalent air opening is acceptable Part No 8316557 2000 Whirlpool Corporation Product dimensions a 73 7 cm gt Pees ee eee eee ee ee I ELECTRIC Jl ce ad 14 19 32 37 1 cm 4 10 depen V4 82cm BACK VIEW 25 1 2 64 8 cm lt at gt 35 88 9 cm
22. tion of pipe fittings must be used to obtain an in line connection to the dryer J m Make sure that lower edges of the cabinet plus the back and bottom sides of the dryer are free of obstructions to permit adequate clearance of air openings for combustion air See Recessed area and closet installation instructions page 12 for minimum spacing requirements K For ease of installation operation and servicing if ever needed adequate space should be provided around the dryer L A 1 8 inch NPT plugged tapping accessible for gauge testing must be installed immediately upstream of the gas supply connection to the dryer The dryer must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 1 2 psig The dryer must be isolated from the gas supply piping system by closing the equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi Electrical requirements A WARNING A Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock Important Observe all governing codes and ordinances A 120 volt 60 Hz AC only 15 or 20 ampere fused electrical supply is required A time delay fuse or circuit brea
23. vered by the exhaust length chart see Whirlpool Service Manual Exhausting Whirlpool Dryers Part No 603197 available from your Whirlpool parts distributor If dryer is installed in a confined area such as a bedroom bathroom or closet it must be exhausted to the outside and provision made for enough air for combustion and ventilation Check governing codes and ordinances See Recessed area and closet installation instructions on Page 12 MAXIMUM LENGTH OF 4 INCH 10 2 cm DIAMETER RIGID METAL VENT 64 FT 19 5 m 64 FT 19 5 m 54 FT 16 5 m 54 FT 16 5 m 44 FT 13 4 m 44 FT 13 4 m 35 FT 10 7 m 35 FT 10 7 m 27 FT 8 2 m 27 FT 8 2 m 58 FT 17 7 m 48 FT 14 6 m 38 FT 11 6 m 29 FT 8 8 m 21 FT 6 4 m MAXIMUM LENGTH OF 4 INCH 10 2 cm DIAMETER FLEXIBLE METAL VENT 36 FT 11 0 m 31 FT 9 4 m 27 FT 8 2 m 25 FT 7 6 m 23 FT 7 0 m 36 FT 11 0 m 31 FT 9 4 m 27 FT 8 2 m 25 FT 7 6 m 23 FT 7 0 m 28 FT 8 5 m 23 FT 7 0 m 19 FT 5 8 m 17 FT 5 2 m 15 FT 4 6 m Four inch metal exhaust vent is required Plan installation to use the fewest number of elbows and turns Page 3 An exhaust hood should cap the exhaust vent to prevent exhausted air from returning into the dryer The outlet of the hood must be at least 12 inches 30 5 cm from the ground or anything else that may be in the oath of the exhaust Four inch outlet
24. w UL approved power supply cord rated 240 volt min 30 amperes and marked for use with a clothes dryer amp WARNING Vj Fire Hazard Use a new UL approved 30 ampere power supply cord Use a UL approved strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock 1 Disconnect the power supply external ground conductor screw terminal block cover 2 Remove hold down screw and terminal block cover Direct wire WARNING Vy Fire Hazard Use 10 gauge solid copper wire Use a UL approved strain relief Disconnect power before making electrical connections Connect neutral wire white or center wire to center terminal silver Ground wire green or bare wire must be connected to green ground connector Connect remaining 2 supply wires to remaining 2 terminals gold Securely tighten all electrical connections Failure to do so can result in death fire or electrical shock strain dryer relief aan cabinet 3 Assemble screws 3 4 U L listed strain relief U L marking on strain relief into the hole below terminal block opening Tighten strai
25. xhaust dryer into a gas vent chimney wall ceiling or concealed space of a building Do not install flexible vent in enclosed walls ceilings or floors If using an existing exhaust system clean lint from entire length of exhaust system Make sure exhaust hood is not plugged with lint The exhaust system should be inspected and cleaned yearly Replace any plastic or metal foil exhaust vent with rigid metal or flexible metal vent Use 4 10 2 cm vent clamps to secure vent system exhaust airflow better good exhaust exhaust airflow airflow Metal flexible vent must be fully extended and supported when the dryer is in its final position DO NOT KINK OR CRUSH THE VENT The metal flexible vent must be completely open to allow adequate exhaust air to flow Allow as much room as possible when using elbows or making turns Bend vent gradually to avoid kinking Remove excess flexible vent to avoid sagging and kinking that may result in reduced air flow Exhaust outlet is located at the center of the bottom dryer back The exhaust vent can be routed up down left right behind the dryer or straight out the back of the dryer Maximum length of exhaust system depends upon the type of vent used number of elbows and type of exhaust hood The maximum length for both rigid and flexible vent is shown in the chart EXHAUST HOOD TYPE 4 4 10 2 cm 10 2 cm 4 Z 10 2 cm For exhaust systems not co
26. y shutoff valves are set in open position Oo Oo KO If you need assistance The Whirlpool Consumer Interaction Center will answer any questions about operating or maintaining your dryer not covered in the Installation Instructions The Whirlpool Consumer Interaction Center is open 24 hours a day 7 days a week Just dial 1 800 NO BELTS 1 800 662 3587 the calll is free When you call you will need the dryer model number and serial number Both numbers can be found on the serial rating plate located on your appliance Printed in U S A

Download Pdf Manuals

image

Related Search

Related Contents

ADV7170/ADV7171  取扱説明書 - 緊急地震速報専用送信機 DPASS  Mode d`emploi du site - La ville de Kaysersberg  25 to 36 - University of Khartoum  User Manual Odyssey7  Alphason Gradino Cantilever  Gigaset DX800A all in one – New and updated functions  NanoMaxx- Ultraschallsystem  Classification Internationale Type de l`Education  Light Box Table - Universal Sewing Supply  