Home

Whirlpool 56OSOLSPC5 816412 Range User Manual

image

Contents

1. 2 1 a 4 Part No 5605019P05 816 INSTALLATION INSTRUCTIONS Before you begin read the following instructions completely and carefully If followed they will simplify the installation job IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES SAVE THESE INSTRUCTIONS FOR THE LOCAL ELECTRICAL INSPECTOR S USE STEP 1 ELECTRICAL REQUIREMENTS This appliance may be connected by means of permanent hard wiring or power supply cord kit It is the personal responsibility of the customer to contact a qualified technician to assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI NPFA 70 latest edition and local codes and ordinances THE RANGE MUST BE CONNECTED WITH COPPER WIRE ONLY Aluminum wire must not be used to avoid potentially unsatisfactory connections POWER SUPPLY CORD KIT This appliance must be connected with a power supply cord kit rated at 125 250 volts minimum 40 amperes and marked for use with ranges Cord must have three 3 conductors For mobile home installation or in areas where local codes do not permit grounding through neutral a four 4 conductor power supply cord kit rated at 125 250 volts minimum 40 amperes and marked for use with ranges shall be used Terminals on end of wires must be either closed loop or open end spade lugs with upturned ends Cord must have strain relief clamp MODELS WITH FACTORY CONNECTED POWER
2. the frame where the grounding strap was re moved See Figure3 Do Not ground to a gas supply pipe or hot water pipe Do Not connect the copper power supply cord to electric power until appliance is perma nently grounded See Figure 4 E Replace terminal block cover SILVER COLORED TERMINAL BARE OR NO 8 GREEN INSULATED COPPER Wee LINE 1 E STRAIN RELIEF TO FUSED WS DISCONNECT BOX OR APPROVED COPPER WIRING DEVICE o POWER SUPPLY CORD FOR COPPER a AMPERES POWER SUPPLY NEUTRAL WHITE OR CENTER CORD FIGURE 3 Cold water pipe must have metal continuity to electrical ground and not be interrupted by plastic rubber or other electrically insulating connectors including water meter or pump without adding a jumper wire at these connections TO APPLIANCE FRAME BARE OR NO 8 GREEN INSULATED COPPER GROUNDING WIRE COPPER ELECTRICALLY GROUNDED COLD GROUNDING WIRE WATER PIPE REMOVE PAINT ETC lt gt KA ON PIPE TIGHTEN NUTS FIRMLY FIGURE 4 COLD WATER PIPE GROUNDING ASSEMBLY GROUNDING CLAMP MUST BE TIGHT ATTACH TO GROUNDED 3 If connecting to a four wire electrical system mobile home A Remove terminal block cover B Remove the ground strap from the terminal block and from the appliance frame Retain the ground screw C Connect the grounding wire green of the copper power supply cord to the frame of the appliance with the grounding screw using the h
3. the range is transported FIGURE 7 CHECK OPERATION Refer to the operation instruction card packaged with the Models 40 with Left Hand Auxiliary Oven range to check for proper care and cleaning of your range 1 Check Large Oven elements as previously described CAUTION Do not touch the elements They may be hot and you may get burned 2 Turn Left Oven thermostat to 400 F The bottom element should heat SURFACE ELEMENTS 3 Turn Left Oven thermostat to BROIL The top element 1 Turn on each of the four 4 surface elements and check should heat to see that they heat On models so equipped check the surface element indicator light s OVEN ELEMENTS CAUTION Do not touch the elements They may be hot and you may get burned 1 Set the timed Oven Selector Switch to MANUAL Eye Level Models Models with Two Position Selector Switch 2 Check the Lower oven by following Steps 1 and 2 for s Models with Pre Heat 1 Turn Selector Switch and thermostat to BROIL Observe the oven elements the upper element only should hast 3 Check the Upper oven by turning the upper oven eat thermostat to HI BROIL The upper element should heat 2 Turn the Selector Switch to BAKE and thermostat to 400 F Observe the oven elements the lower element only should heat l 4 Reset the Upper oven thermostat to OFF and turn back to 400 F Both elements should be on at first After the thermostat cycles the bottom element only
4. SUPPLY CORD Some models may be equipped with a factory connected three 3 conductor power supply cord In mobile home installations or in areas where local codes do not permit grounding through neutral a four 4 conductor power supply cord kit rated at 125 250 volts minimum 40 amperes and investigated for use with ranges shall be used Terminals on end of wires must be either closed loop or open end spade lugs with upturned ends STEP 2 GENERAL The back of a Free Standing Range may be installed against a vertical wall The sides may be installed against base Cabinets or against vertical walls extending above the upper edge of the cook top To prevent possible discoloration of the base cabinets the front of the oven frame must extend at least V2 past the front surface or cabinet doors of the base cabinets To eliminate the hazard of reaching over heated surface elements cabinets or storage spaces should not be provided over a range If cabinets are provided the hazard can be reduced by installing a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets CAUTION 30 inches minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet 24 inches minimum when bottom of wood or metal cabinet is protected by not less than V inch thick flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 inch thick stainless ste
5. el 0 024 inch thick aluminum or 0 020 inch thick copper When installing the range between base cabinets refer to Figure 1 for the size of the opening needed Do Not seal range to cabinets CAUTION When unpacking the range do not discard the 4 shipping bolts as these are the leveling legs If a service cord is used the wall receptacle should be located in accordance with the dimensions given in Figure NOTE The Overall Height of Eye Level Models is 66 3 16 A 30 RANGES 30 3 8 TO 30 1 2 40 RANGES 40 3 8 TO 40 1 2 B NOTE COPPER SERVICE CORD OR POWER SUPPLY CORD PIGTAIL MUST RUN DOWNWARD LEFT OR RIGHT TO WALL RECEPTACLE TO AVOID PINCHING CORD BETWEEN REAR PORTION OF RANGE AND WALL c 30 amp 40 RANGES 15 TO 19 MICROSHELF RANGE 8 TO 10 FIGURE 1 ON MODELS SO EQUIPPED BE SURE THE BOTTLE OF CLEANER CONDITIONER PACKED WITH THE RANGE IS LEFT WHERE THE USER CAN FIND IT EASILY IT IS IMPORTANT THAT THE GLASS CE RAMIC SMOOTH TOP BE PRE TREATED BEFORE BEING USED STEP 3 ELECTRICAL CONNECTION WARNING Disconnect electrical suppiy before making electrical connection Failure to do so may result in electrical shock or personal injury ELECTRICAL GROUND APPLIANCE This appliance is manufactured with the neutral terminal connected to the frame 1 If local codes permit connection of the frame grounding conductor to the neutral wire of the coppe
6. ole in the frame where the grounding strap was removed See Figures D Connect the neutral white wire of the copper power supply cord to the center silver colored termina of the terminal block and connect the other wires to the outer terminals Ring type terminals must be used on the copper power supply cord wires E Replace the terminal block cover SILVER COLORED TERMINAL BARE OR NO 8 GREEN INSULATED CNE COPPER GROUNDING NEUTRAL WIRE WHITE OR CENTER DISCONNECT BOX _ a OR APPROVED 4 WIRE COPPER POWER SUPPLY CORD WIRING DEVICE 40 AMPERES POWER SUPPLY CORD FIGURE 5 STEP 4 LEVEL AND POSITION RANGE 1 Move the range to its final operating position and check the level of the range by using a small spirit level on the oven rack See Figure 6 The range can be leveled from side to side and front to rear by adjusting the four leveling legs UIE FIGURE 6 2 Make the electrical connection A Plug the flexible copper connector pigtail into an approved receptacle where local codes permit the use of a pigtail OR B Connect the flexible armored or non metallic shielded copper cable directly to a fused disconnect box 3 Remove the tape holding the oven light switch actuator See Figure 7 NOTE As shipped from the factory the oven light switch actuator is held depressed by tape To prevent switch damage the switch actuator should be taped whenever
7. ong distance A special operator will tell you Ihe name and number of TECH CARE your nearest Whirlpool TECH CARE service outlel During normal working hours Whirlpool consultants al this same number will also answer any questions aboul operating or maintaining your appliance not erm cane gt covered in your Use and Care Guide HOME PRODUCTS SERVICE Learn the benefils ol using TECH CARE service for maintaining Ihe quatity originally built into your Whirlpool appliances WHIRLPOOL CORPORATION BENTON HARBOR MICHIGAN 49022 5
8. r power supply cord A Remove the terminal block cover lowest wire cover IS REQUIRED ON THIS B The terminal nuts are taped to the frame below the terminal block NOTE Do not loosen factory installed nuts C Connect the neutral wire of the copper power supply cord to the center silvercolored terminal of the terminal block and connect the other wires to the outer terminals See Figure 2 Ring type terminals must be used on the copper power supply cord wires D Replace terminal block cover GROUNDING STRAP NEUTRAL WHITE OR CENTER TO FUSED DISCONNECT BOX OR APPROVED WIRING DEVICE FOR COPPER POWER SUPPLY CORD COPPER POWER SUPPLY CORD 40 AMPERES FIGURE 2 2 If local codes DO NOT permit frame grounding to the neutral wire of the copper power supply cord A Remove terminal block cover B Remove the ground strap from the terminal block and from the appliance frame Retain the ground screw C Connect the neutral wire of the copper power supply cord to the center silver colored terminal of the terminal block and connect the other wires to the outer terminals See Figure 3 Ring type terminals must be used on the copper power supply cord wires D Connect a separate insulated green colored copper grounding wire No 8 minimum to a grounded cold water pipe by means of a clamp and then to the frame of the appliance with the grounding screw using the hole in
9. will cycle On and Off to maintain the selected oven temperature Models with Pre Heat 1 Turn the Selector Switch to PRE HEAT and thermostat to 400 F and observe the oven elements Both elements should heat 2 Turn thermostat to BROIL and Selector Switch to CLOCK If so equipped HI BROIL and observe the oven elements Upper element Refer to the operation instructions packaged in the range only should heat oven for operation of the clock NOTE On standard and continuous cleaning models be sure timer is set for Manual operation On self cleaning models set the Bake Clean switch to BAKE BEFORE YOU CALL FOR SERVICE 1 Make sure range copper power cord pigtail is plugged y NOTE The serial plate for 30 ranges is located on the in upper left corner of the oven front frame On 40 models 2 Check to make sure the house fuse or circuit breaker for the serial plate is on the front frame of the small left your range is not blown or open compartment or oven In the event your WHIRLPOOL appliance should need service call Ihe dealer from whom you purchas gt ed the appliance or a WHIRLPOOL franchised TECH CARE service company He s in the Yellow Whirlpool Pages of your telephone directory listed under Appliances Household Major Service and Repair You OCILI can also obtain his name and number by dialing free Ihe Whirlpoo COOL LINE Service 800 253 1301 lt Dial just as you normaily dial l