Home

Weber 43267 Gas Grill User Manual

image

Contents

1. S 660TM S 460TM WWW WEBER COM ASSEMBLY 18 ASSEMBLY any holes for the 1 vent make la 6 35 mm sure the cookbox Drill Bit is flush with the front of the grill frame A ATTENTION 78 e Before drilling 2 7 7 WWW WEBER COM ASSEMBLY S 460m AAAAA LOOANAAANADAN WWW WEBER COM 20 ASSEMBLY FETTE e
2. ATTENTION This product has been safety tested and is only certified for use in a specific country Refer to country designation located on outer carton These parts may be gas carrying or gas burning components Please contact Weber Stephen Products Co Customer Service Department for genuine Weber Stephen Products Co replacement part s information WARNING Do not attempt to make any repair to gas carrying gas burning igniter components or structural components without contacting Weber Stephen Products Co Customer Service Department Your actions if you fail to follow this Product Warning may cause a fire an explosion or structural failure resulting in serious personal injury or death as well as damage to property 1 1 1 e WEBER STEPHEN PRODUCTS www weber com 2009 The following trademarks are registered in the name of Weber Stephen Products Co an Illinois corporation located at 200 East Daniels Road Palatine Illinois 60067 U S A Australia Smokey Joe Weber Kettle Silhouette Genesis Austria Kettle Silhouette amp Smokey Joe Weber Benelux Kettle Silhouette Smokey Joe Weber Compact Grill Configura tion Botswana Weber Canada Smokey Joe Genesis China Kettle Silhouette Denmark Kettle Silhouette Smokey Joe Weber Finland Smokey Joe France Kettle Silhouette Smokey Joe Weber One Touch Germany Smokey Joe Weber One Touch Greece
3. ISLAND STRUCTURE CONFIGURATION OPTIONS Summit 4 burner 6 burner grill Gas supply Optional sideburner accessory NOTE IF YOU HAVE PURCHASED A SIDEBURNER If you have purchased a Side Burner accessory with your Summit gas grill Weber recommends that you read the SUMMIT BUILT IN SIDEBURNER INSTALLATION OWNER S GUIDE before designing your island structure WWW WEBER COM 4 BUILT IN CUTOUT DIMENSIONS BUILT IN STRUCTURE CUTOUT DIMENSIONS ALL DIMENSIONS ARE TO FINISHED SURFACES A WARNING All countertop finished surfaces must be constructed of a noncombustible material BUILT IN CUTOUT DIMENSIONS S 460 S 660 TOLERANCES 1 4 768 35 mm 38 1 4 971 55 mm lu 1 4 6 35mm 34 3 6 873 13 mm 343 873 13 mm 14 6 35mm 23 584 2 mm 23 584 2 mm Ju 1 4 6 5mm GENERAL CONSTRUCTION DETAILS Summit Built In unit and all other accessory units should be on site before construction begins All dimensions have a tolerance of plus or minus inch 6 35 mm The grill frame rests directly on the Island Structure top finished surface Make sure this surface is level Do not support the grill from the bottom If the supporting structure is going to have an electrical outlet for a rotisserie it should be on the left side of the structure BUILT IN CUTOUT DIMENSIONS S 460 S 660 24 minimum 610 mm 24 minimum
4. CE OOO O0 OO 90 00 960 CC 000000 LI WWW WEBER COM ASSEMBLY 60004 4 C 19 ae lA WWW WEBER COM ASSEMBLY WWW WEBER COM ASSEMBLY 23 26 0 dil 1 vr 2 The Weber Grill Out Handle Light has Tilt Sensor Lid up ON Lid Closed OFF The power button a activates or deactivates the Tilt Sensor For daytime use deactivate the sensor by pressing power button a Requires 3 alkaline batt
5. 90 fitting 1 2 12 7 mm Flared Gasket Cap Optional Side Burner WWW WEBER COM GAS SUPPLY VENTILATION WARNING Ventillation holes must be provided in the structure at the top and bottom to provide ventilation in the event of a gas leak Ventilation holes can be located in a low visibility area and should be protected by screening material to prevent rodents and insects from entering the structure Air holes will also help dry moisture Note These drawings are only a reference Cross ventilation must be incorporated in the supporting structure We recommend a minimum of 100 square inches 254 square cm of venting per side Vents should be on two sides of the structure The above drawings are for reference only Location of the vents should be from the center outward Locate the vents at both the bottom of the structure and at the top of the structure The bottom vents should be as close to ground level as possible Make sure the vent area is not blocked by interior supports of the structure We recommend vents with screens Access doors to the structure are not considered vents Clean the vents periodically DANGER Failure to follow recommended minimum venting instructions can cause gas to collect in the structure in the event of a gas leak This may result in a fire or an explosion which can cause serious bodily injury or death and damage to property
6. Smokey Joe Ireland Kettle Silhouette Smokey Joe Italy Smokey Joe Weber Japan Smokey Joe Weber Korea Smokey Joe Weber New Zealand Weber Smokey Joe Nigeria Weber Norway Smokey Joe Weber Portugal Weber South Africa Smokey Joe Weber Kettle Configuration Spain Smokey Joe Weber Sweden Kettle Silhouette Smokey Joe Switzerland Kettle Silhouettet Smokey Joe Weber United Kingdom Smokey Joe Weber Weber One Touch U S A Kettle Configuration Kettle Silhouette Smokey Joe Weber One Touch Firespice Go Anywhere U S A Kettle Configuration Kettle Silhouette Genesis Flavorizer Crossover Flamgo Performer Rapidfire Tuck N Carry Jumbo Joe Bar B Kettle Master Touch Spirit Grill Out Summit Platinum 1 800 Grill Out Ranch Matchless Flame Zimbabwe Weber Kettle Configuration Kettle Silhouette
7. be constructed with non combustible materials The remote LP cylinder enclosure should isolate the LP cylinder from the burner compartment so that it provides shielding from radiation be flame barrier and provide protection from foreign material such as hot drippings E There should be a minimum of 2 inches 50 8mm between the ground and the floor of the remote LP cylinder enclosure F The LP cylinder valve should be readily accessible for hand operation A door on the remote LP cylinder enclosure to gain access to the LP cylinder valve is acceptable provided it is non locking and can be opened without the use of tools A DANGER Use of any hose and regulator assembly other than that provided or recommended by Weber Stephen Products Inc could be dangerous and may not provide adequate gas supply to the Summit Built In gas grill and could result in a fire or an explosion causing serious bodily injury or death and damage to property A DANGER Failure to build a remote LP cylinder enclosure for a single 20 Ib cylinder only following the requirements for ventilation cylinder retention and separation of the LP cylinder from a heat source listed in the ANSI Standard for Outdoor Cooking Gas Appliances ANSI Z21 58 CSA 1 6 could be dangerous and could result in a fire or an explosion causing serious bodily injury or death and damage to property If you do not follow the DANGER statements exactly the Warranty on the Summit Buil
8. breezeway shed under an unprotected overhang or other enclosed area Locate the grill and structure so there is enough room to safely evacuate the area in case of a fire CLEARANCE FROM SURFACES OR STRUCTURES WARNING Clearance from any surface or structure is 24 inches 609 6 mm from the back and sides of the grill Refer to Typical Gas Supply Installation before starting installation A WARNING The structure island countertops and adjacent work areas for the built in grill installation must be built from noncombustible materials only NOTE If you have questions on what materials are considered noncombustible contact your local building materials supplier or fire department Note For a countertop treatment Recommended 3 4 19 1 mm overhang Notch front edge for frame to fully slide in WWW WEBER COM BUILT IN CUTOUT DIMENSIONS 3 ISLAND STRUCTURE CONFIGURATION OPTIONS There are many available options for locating the major components of your Island structure Your major components are 1 The Built in Grill 2 Gas supply enclosure 3 Optional Side burner accessory The 3 common options A B C are illustrated in the Island Structure Configuration Options table NOTE GAS LINE LIMITATION The gas supply hose from grill manifold to gas supply bulkhead must not exceed 58 147cm The 3 8 9 52 Side Burner accessory hose not included must not exceed 58 147cm
9. 610 mm 4 34 120 65 43 120 65 6 1 4 158 75 mm 6 11 158 75 10 d 266 7 mm minimum 10 1 266 7 mm minimum 23 584 2 mm 23 584 2 mm 34 3g 873 13 mm 34 3 873 13 mm 27 685 8 mm minimum distance from front edge of 27 685 8 mm minimum distance from front edge of the cutout for open lid clearance the cutout for open lid clearance 30 104 768 35 Built In Frame 38 I 971 55 mm Built In Frame DIMENSIONS Note For a countertop treatment Recommended 3 19 1 mm overhang Notch front edge for frame to fully slide in Gas Inlet Side Burner Opening Access for electric on left hand side Clearance from any surface or structure is at least 24 609 6mm from the back and sides of the grill or side burner WWW WEBER COM PARTS LIST Left Door 1 Cookbox 1 Right Door 1 Warming Rack 1 S 660 LI 1 Right Enclosure Panel 1 Cookbox 1 Left Enclosure Panel 1 Front Frame Rail 1 Front Vent Panel 1 Rear Frame Rail 1 Rear Panel Assembly 1 Rear Vent 1 Bottom Shelf 1 Corrugated Gas Line 1 WWW WEBER COM PARTS LIST Flavorizere Bars Smoker Bar 1 S 460 8 S 660 12 Stainless Steel Cooking Grates 1 2 inch Bolts 20 1 2 inch Bolt 10 5 460 2 TM 2 S 660 3 Nylon Washer 10 Collection Tray 1 Hinge
10. BUSTIBLE SURFACES OR STRUCTURES A WARNING Clearance from the outside walls of the sides and back of the LP Tank Enclosure must be a minimum of 24 60 96cm any surface Refer to Typical Gas Supply Installation before starting installation A WARNING The structure island counter tops and adjacent work areas for the LP Tank Enclosure must be built from noncombustible materials only NOTE If you have questions on what materials are considered noncombustible contact you local building supplier or fire department WWW WEBER COM WWW WEBER COM PARTS LIST ASSEMBLY Hose and regulator 1 Tank stand 1 Tank stand base 1 Tank Scale 1 1 4 20 nut 6 Nylon washer 12 1 4 20 x 1 2 bolt 6 Cylinder glide 2 1 2 Flare Gasket 2 3 8 Flare Gasket 2 H 30 LIST ASSEMBLY MOUNTING THE L TANK Mount the LP tank bracket to the right hand side of the enclosure opening using non corrosive hardware Mounting holes are provided on the sides and bottom of your LP tank bracket Be sure to mount the bracket securley to the enclosure before use MOUNTING HARDWARE NOT INCLUDED MOUNTING THE LP HOSE AND REGULATOR Securley mount the hose and regulator bracket to the top of the built in tank enclosure using non corrosive hardware E umi MOUNTING HARDWARE NOT INCLU
11. DED LP TANK ENCLOSURE GAS LINE LOCATIONS Area should be kept clear of sharp jagged or extremely abrasive surfaces to avoid possible damage to gas supply lines Exercise caution when pulling gas lines through built in structure I T WWW WEBER COM GAS SUPPLY CONNECT GAS SUPPLY A 58 inch 14732 cm corrugated gas line is supplied with the grill This line needs to pass through the gas inlet opening to the main gas supply 1 Connect the corrugated gas line to the manifold located on the right hand side of grill under the control panel Use the 1 2 flared gasket 1 to ensure proper seal Note 1 2 flared gaskets are included in the Summit Built In tank Enclosure Kit included with your grill The corrugated line passes through the Island Structure cavity to the hose and regulator connection inside the tank enclosure Shown in illustration 2 Uncap one flare fitting from the 90 Connection on the regulator hose located inside the tank enclosure 3 Use the 1 2 12 7 mm inch flared gasket to ensure proper seal NOTE Only use the 3 8 inch 9 53 mm flared gasket if you are installing the optional side burner 4 Connect the corrugated gas line to the 90 Connection CONNECTION CHART Top View Typical tank cabinet or tank enclosure location Side View Top of Box Back of Box Corrugated Gas Line to Manifold
12. Gas Inlet A CAUTION If young children are in the area a locking valve should be considered Pipe compound should be used which is resistant to the action of liquid propane gas when gas connections are made The gas connections must be firmly attached to rigid permanent construction Note The information provided in this manual is general for typical installations We cannot cover all possible installation ideas We recommend prior to installation that you contact your municipality for local building codes and your local fire department for installation verification If you have any questions contact Customer Service at 1 800 446 1071 WWW WEBER COM GAS SUPPLY Maximum Capacity of Metallic Pipe in Cubic Feet of Gas per Hour for Gas Pressures of 2 psi or Less and a Pressure Drop of 0 3 Inch Water Column Based on a 0 60 Specific Gravity Gas Nominal Iron Pipe Size Inches Length of Pipe Feet 80 90 100 125 150 175 200 46 42 40 38 33 30 28 26 95 89 83 79 70 63 58 54 179 167 1977 148 131 119 109 102 1 060 368 343 322 304 269 244 224 209 1 580 1 090 552 514 482 455 403 366 336 313 3 050 2 090 1 060 989 928 877 777 704 648 602 4 860 3 340 1 690 1 580 1 480 1 400 1 240 1 120 1 030 960 8 580 5 900 3 000 2 790 2610 2 470 2 190 1 980 1 820 1 700 17 500 12 000 6 110 5 680 5 330 5 040 4 460 4 050 3 720 3 460 2009 National Fire Protection Association In
13. L TF 77 mh GAS GRILL Built In LP Gas Grill Installation Guide Tank Enclosure Installation Pg 27 S 460 S 660 43267 YOU MUST READ THIS OWNER S GUIDE A WARNING Follow all leak check BEFORE OPERATING YOUR GAS GRILL procedures carefully in this manual prior to barbecue operation Do this even if the barbecue was dealer assembled A DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flames 3 Open lid 4 If odor continues keep away from the appliance and immediately call your gas THIS GAS APPLIANCE IS DESIGNED FOR supplier or your fire department OUTDOOR USE ONLY Leaking gas may cause a fire or explosion which can cause serious bodily injury or death or damage to property NOTICE TO INSTALLER These instructions must be left with the owner and the owner should keep them for future use A WARNING Do not try to light this appliance without reading the Lighting Instructions section of this manual A WARNING Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance National PROPANE GAS Association CERTIFIED 43267 US 06 11 09 LP ENGLISH DANGER Failure to follow the Dangers Warnings and Cautions contained in this Owner s Manual may result in seriou
14. LEE SE SAS 2 SOQ AAA CLEARANCES 1 24 610 mm Any Surface Grill Frame E Note For a countertop treatment Recommended 19 1 3 4 inch over hang Notch front edge for frame to fully slide in WWW WEBER COM 12 ASSEMBLY 114 6 35 mm Drill Bit S 460 S 660 WWW WEBER COM ASSEMBLY Dr S SL Apply a bead of silicone sealant 1 around the perimeter and front edges of the grill that are in contact with the island structure This will prevent moisture seepage The sealant you use must have a temperature rating above 120 F 48 8 C ATTENTION Before applyin
15. Pin 2 Catch Pan Holder 1 Hair Pin Cotter 2 10 24 1 inch Steel Screw 2 Catch Pan 1 Locking Washer 2 Disposable Drip Pans 2 10 32 x 1 4 inch Steel Screw 5 Battery Housing 1 74 20 x 1 2 inch Truss Head Screw 2 Right Front Vent Clip 1 10 Sheet Metal Screw 3 Left Front Vent Clip 1 Flat Head Screw 2 Plastic Anchors 5 Rotisserie 1 Rotisserie Fork 4 Keps Nuts 1 4 x 20 Keps Nut 2 Rotisserie Motor 1 1 inch Bolt 14 20 x 1 inch Bolt 2 Handle Hardware 4 Rotisserie Bracket 1 Handle 2 Wire Tie 1 Smoker 1 7 16 inch Wrench 1 WWW WEBER COM ASSEMBLY H Door Stop Bracket A should be positioned as shown d A ATTENTION Do not attach rear support screws and washers until Step 6 WWW WEBER COM 8 ASSEMBLY WWW WEBER COM 21 2 TT lt WWW WEBER COM ASSEMBLY WWW WEBER COM ASSEMBLY A CAUTION Use two people to lift and install the Summite Built In frame assembly A Lift the frame assembly into the island structure opening Make sure the frame is resting level on the finished surface of the structure B Adjust the Front Vent to rest squarely on ground FT 141 SCOP
16. W WEBER COM BUILT IN TANK ENCLOSURE INSTRUCTIONS A DANGER LOCATING YOUR LP TANK ENCLOSURE KIT When determining a suitable location for your LP Tank Enclosure Kit installation give Use of any other hose and regulator assembly could be attention to concerns such as proximity to traffic paths and keeping any gas supply dangerous and may provide adequate gas supply to as wee Never cl the re a A a Seier reezeway Shed under an unprotected overhang or other enclosed area Locate the the Summit Built In gas grill and could result in a fire or Tank Enclosure Kit and structure so there is enough room to safely evacuate the area in an explosion causing serious bodily injury or death and case of a fire damage to property A DANGER Failure to build LP cylinder enclosure for a 20 cylinder following the requirements for ventilation cylinder retention and separation of the LP cylinder from a heat source listed in the ANSI Standard for Outdoor Cooking Gas Appliances ANSI Z21 58 CSA 1 6 could be dangerous and could result in a fire or an explosion causing serious bodily injury or death and damage to properity If you do not follow the DANGER statements exactly the Warranty on the Summit Built In gas grill will be voided ENCLOSURE CHART 1 24 inches 610 mm Any Surface Tank Enclosure b Any Surface Non Combustible Surface CLEARANCE FROM COM
17. c and International Approval Services U S Inc All Rights Reserved TEST CONNECTIONS All connections and joints must be thoroughly tested for leaks in accordance with local codes and all listed procedures in the latest edition of the National Fuel Gas Code ANSI 2223 1 54 Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 or the Standard for Recreational Vehicles ANSI A 119 2 NFPA 1192 and CSA Z240 RV Series Recreational Vehicle Code as applicable A DANGER Do not use an open flame to check for gas leaks Be sure there are no sparks or open flames in the area while you check for gas leaks This will result in a fire or explosion which can cause serious bodily injury or death and damage to property WWW WEBER COM 26 GAS SUPPLY TYPICAL 20 LP PROPANE GAS SUPPLY INSTALLATION The remote tank enclosure kit provided with your Weber Built In grill shall be used for installations using a 20 Ib LP cylinder mounted in an island structure The remote tank enclosure shall house the included hose and regulator assembly and gas connections the tank bracket and the fuel scale for connecting a remote mounted LP oylinder to the Summit Built In gas grill The hose and regulator is listed as a required part of the CSA listed Summit Built In gas grill A properly installed tank enclosure meets the requirements for venting tank retention and separation of the LP cylind
18. er from a heat source as outlined in the ANSI Standard for Outdoor Cooking Gas Appliances Z21 58 CSA 1 6 for LP enclosures You need to hire a licensed contractor or licensed plumber and they need to follow the requirements described in the ANSI Standard for Outdoor Cooking Gas Appliances Z21 58 CSA 1 6 for LP enclosures The requirements described in the Standard for Outdoor Cooking Gas Appliances Z21 58 CSA 1 6 are as follows A remote enclosure for an LP gas cylinder shall be ventilated by openings at both the upper and lower levels of the cylinder This shall be accomplished by one of the following A One side of the remote LP cylinder enclosure shall be completely open or B If the remote LP cylinder enclosure is designed to have four sides a top and a bottom ventilation is required for the remote LP cylinder enclosure 1 There should be at least two ventilation openings a hole or group of holes for the purpose of ventilation in the sidewalls of the island structure The openings should be located within 5 inches 127mm of the top of the enclosure The ventilation openings should be equally sized and spaced at a minimum of 90 degrees and be unobstructed The openings shall have a total free open area of not less than 20 square inches This relates to 1 square inch of ventilation area per pound of stored fuel capacity Ventilation openings a hole or group of holes for the purpose of ventilation should be provided at floo
19. eries not included Se WWW WEBER COM 24 BUILT IN GAS LINE LOCATIONS Note Leave an access in the island structure for gas supply and regulator service that is not inside the grill structure Area should be kept clear of sharp jagged extremely abrasive surfaces to avoid possible damage to gas supply lines Exercise caution when pulling gas lines through built in structure TYPICAL BULK PROPANE GAS SUPPLY INSTALLATION We recommend that this installation be done by a LICENSED professional GENERAL SPECIFICATIONS FOR PIPING Note Contact your local municipality for building codes regulating outdoor gas grill installations In absence of Local Codes you must conform to the latest edition of the National Fuel Gas Code ANSI 2223 1 54 Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 or the Standard for Recreational Vehicles ANSI A 119 2 NFPA 1192 and CSA Z240 RV Series Recreational Vehicle Code as applicable This grill is designed to operate at 11 inches of water column pressure An LP in line regulator may be necessary for this pressure GAS SUPPLY BUILT IN GAS LINELOCATIONS NE 460 S 660 TOLERANCES 4 4 3 8mm 120 65 mm 120 65 mm 3 8mm 6 6 158 8 mm 158 8 mm 3 8mm e 3 8mm 2 2 63 5 mm 63 5 mm 3 8mm 3 8mm Plan View Left Side View
20. g any silicone sealant make sure the cookbox is flush with the front of the grill frame WWW WEBER COM 14 ASSEMBLY 000000000 4 o BATTERY HOUSING WIRING s BACKWRE 3 Sea s Sne WARNING Make sure that all control knobs are turned to the OFF position before connecting the gas supply and operating the grill WWW WEBER COM ASSEMBLY Requires 3 D alkaline batteries Included Use alkaline 2 batteries only Do mix old and new batteries or different types of batteries standard alkaline or rechargeable WWW WEBER COM ASSEMBLY 16 S 660 S 460TM o CC CC
21. r level The ventilation openings should have a total free area of not less than 10 square inches This relates to 1 2 square inch of ventilation area per pound of stored fuel capacity There should be at least two ventilation openings if the ventilation openings at floor level are in the sidewall The ventilation openings should be within 5 inches 127mm of the floor The ventilation openings should be of equal size and be spaced at a minimum of 90 degrees and should be unobstructed 3 The minimum size of the ventilation hole s should not be less than 1 4 inch 4 The ventilation openings in the sidewalls should not allow venting into the empty or hollow area of the island If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure the gas should not be allowed to vent or migrate into the empty or hollow area of the island Ventilation openings in the sidewalls of the enclosure should only communicate with the outside of the island structure so that the gas can dissipate outside of the island structure 2 BK If the remote LP cylinder enclosure has four sides a top and bottom and is intended for installation in a built in island enclosure 1 At least one ventilation opening a hole or group of holes for the purpose of ventilation needs to be on one side of the enclosure that communicates with the outside of the island structure If a gas leak should occur or the LP cylinder
22. re in place The unit must be properly assembled according to the instructions outlined in the Assembly Instruction section of the Owner s Guide Proposition 65 Warning Handling the brass material on this product exposes you to lead a chemical known to the state of California to cause cancer birth defects or other reproductive harm Wash hands after handling this product LIQUID PROPANE GAS UNITS ONLY A A A Use the regulator that is supplied with your Weber Tank Enclosure Kit Do not attempt to disconnect the gas regulator or any gas fitting while your barbecue is in operation A dented or rusty liquid propane cylinder may be hazardous and should be checked by your liquid propane supplier Do not use a liquid propane cylinder with a damaged valve Although your liquid propane cylinder may appear to be empty gas may still be present and the cylinder should be transported and stored accordingly If you see smell or hear the hiss of escaping gas from the liquid propane cylinder 1 Move away from liquid propane cylinder 2 Do not attempt to correct the problem yourself 3 Call your fire department BUILT IN CUTOUT DIMENSIONS LOCATING YOUR GRILL When determining a suitable location for your Summit gas grill installation give attention to concerns such as exposure to wind proximity to traffic paths and keeping any gas supply lines as short as possible Never locate the Summit gas grill in a garage
23. s bodily injury or death or in a fire or an explosion causing damage to property WARNINGS Do not store a spare or disconnected liquid propane cylinder under or near the barbecue Improper assembly may be dangerous Please carefully follow the assembly instructions in this manual Do not operate the Weber gas barbecue if there is a gas leak present Do not use a flame to check for gas leaks Combustible materials should never be within 24 60 96cm inches of the top bottom back or sides of your Weber gas barbecue Do not put a barbecue cover or anything flammable on or in the storage area under the barbecue Your Weber gas barbecue should never be used by children Accessible parts of the barbecue may be very hot Keep young children away while it is in use A You should exercise reasonable care when operating your Weber gas barbecue It will be hot during cooking or cleaning and should never be left unattended or moved while in operation Liquid propane gas is not natural gas The conversion or attempted use of natural gas in a liquid propane unit or liquid propane gas in a natural gas unit is dangerous and will void your warranty Do not attempt to disconnect any gas fitting while your barbecue is in operation gt gt gt E gt gt Keep any electrical supply cord and the fuel supply hose away from any heated surfaces Do not use this Weber tank enclosure kit unless all parts a
24. should vent in the LP cylinder enclosure the gas should not be allowed to vent or migrate into the empty or hollow area of the island Ventilation openings should only communicate with the outside of the island structure so that the gas can dissipate outside of the island structure The ventilation opening should be located within 5 inches 127mm of the top of the enclosure and should have a total free area of 20 square inches This relates to 1 square inch of ventilation area per pound of stored fuel At least one ventilation opening a hole or group of holes for the purpose of ventilation needs to be on one side of the enclosure that communicates with the outside of the island structure at the bottom If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure the gas should not be allowed to vent or migrate into the empty or hollow area of the island Ventilation openings should only communicate with the outside of the island structure so that the gas can dissipate outside of the island structure The ventilation opening should be located within 5 inches 127mm of the bottom of the enclosure and should have a total free area of 10 square inches This relates to 1 4 square inch of ventilation area per pound of stored fuel 3 The minimum size of the ventilation hole s should not be less than 1 4 inch 6 35mm 2 The remote LL cylinder enclosure should
25. t In gas grill will be voided WWW WEBER COM BUILT IN TANK ENCLOSURE INSTRUCTIONS I I VI J I OPERATING WARNING Only use the Weber Tank Enclosure Kit outdoors in a well ventilated area Do not use in a garage building breezeway or any other enclosed area WARNING Your Weber Tank Enclosure Kit shall not be used under an unprotected combustible roof or overhang WARNING Your Weber Tank Enclosure Kit is not intended to be installed in or on recreational vehicles and or boats WARNING Keep any electrical supply cord and the fuel supply hose away from any heated surface WARNING Never store an extra spare LP cylinder under or near the Weber gas barbecue WARNING Keep the ventilation openings of the cylinder enclosure free and clear of debris WARNING Turn off the gas at the LP gas supply cylinder when the outdoor cooking gas appliance is not in use WARNING Never store an outdoor cooking gas appliance indoors unless the LP cylinder is disconnected and removed from the outdoor cooking gas appliance WARNING LP Cylinders must be stored outdoors out of the reach of children and must not be stored in a building garage or any other enclosed area WARNING The LP pressure regulator and hose assembly supplied with the Weber Tank Enclosure Kit must be used Replacement LP pressure regulators and hoses must be obtained from Weber Stephen Product Co WW

Download Pdf Manuals

image

Related Search

Related Contents

GET PDF - Toshiba  ライブ SR 用 ミキシング・コンソール 取扱説明書  取扱説明書  Colour Light Output  Tecnoware UPS ECO 0.85  Manuel d`utilisation  Targus Hughes Leather Portfolio Slipcase f/ iPad  5.1 Files - Byggeweb  平成17年度 所管公益法人等以外の者との間で締結された随意  Aicarr - Per Continuare nel sito Lender  

Copyright © All rights reserved.
Failed to retrieve file