Home
UNICOM Electric FEP-31016T
Contents
1. power supply Dimensions 440mm x 161mm x 44mm LxWxH 17 6 x 6 44 x 1 76 LxWxH Operating temperature O C to 45 C 32 F to 113 F Rack mounting Brackets Figure 1 Contents of package IMPORTANT If any piece is missing or damaged please contact your local dealer or reseller for service Storage temperature 40 C to 70 C 40 F to 158 F Humidity 10 to 90 non conditioning LLL LLL EMI FCC Class A CE mark For Your Records Safety UL cUL Product Name Serial Number Date of Purchase FCC Statement Purchased from This equipment has been tested and found to comply with the limits for a class B device Notes pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s expense 8 1 Introduction The Dyna Switch 16 and Dyna Switch 24 Auto MDI MDIX are Fast Ethernet switches that provide wire speed a Fast Ethernet switching function which allows high performance low cost connections to Full duplex Half duplex 10Mbp
2. servers and a local server attached are both connected to a Dyna Switch All of the devices in this network can communicate with each other through the Dyna Switch Connecting servers to the switch allows other users to access the server s data ai Server 3 QM omes Ss Workstations Figure 6 Segment Bridge Application Hardware Description The Front Panel The Front Panels of the Dyna Switch 16 and 24 consist of 10 100Base TX RJ 45 ports and LED Indicators Figure 2 Front Panel views of Dyna Switch 16 and 24 The Rear Panel The 3 pronged power plug is located at the rear panel of the switches as shown in the Figure 3 The Switch operates on AC in the range 100 240V AC 50 60Hz er 1 Figure 3 Rear panel view of the Dyna Switch 16 and 24 LED Indicators The LED Indicators give real time information of systematic operation status The following table provides descriptions of the LED status and their meanings Per Device Power Per Port LINK ACT Link Activity FDX COL Full duplex Collision For LED indication details please refer to page 4 Network Application UNIG M Dyna Switch 16 This section provides a few samples of network topology in which the Switches are used The Dyna Switch 16 and 24 are designed to be used as segment switches With their large address tables 8K MAC A address and high performance they are ideal for interconnecting 16 Port 10
3. 100Base TX Switch Moco CE 9 40 11 12 13 14 15 POWER LINK ACT and FDX COL networking segments Indicators You can use the Dyna Switch 16 and 24 to connect PCs workstations and servers to each other by connecting these devices directly to a Switch The switch automatically learns node addresses which are subsequently used to filter and forward all traffic based on the destination address Power Indicator Figure 4 Front panel view of LED indicators Status LEDs E gt _ stats coor_ e _ re re The Dyna Switch 16 and 24 can be used as standalone switches Power Green The switch is supplied with F interconnecting personal computers servers and print servers forming a suitable power cai _ The port is connecting with the device LINK ACT Blinks The port is receiving or transmitting data Orange The port is operating in Full a The port is not linked successfully with the device Duplex mode Is FDX COL Blinks A packet collision occurred at a q A P nba gyr No device attached or the port is N Workatai ne operating in Half Duplex mode Figure 5 Small Workgroup Application
4. A Network Systems Solution a 908 Canada Court City of Industry CA 91748 U S A Phone 626 964 7873 or 800 346 6668 Fax 626 964 7880 www unicomlink com e mail info unicomlink com UNICOM 2001 UNICOM and A Network Systems Solution are trademarks of UNICOM Electric Inc All rights reserved Specifications subject to change without notice Rev 12 02 A Network Systems Solution COM Dyna Switch 16 Dyna Switch 24 16 Port or 24 Port 10 100Base TX Switch FEP 31016T 1 FEP 31024T 1 aoe oooh T TITILL addig ee coven User s MANUAL Necessary Cables UTP Unshielded Twisted Pair Cable Package Contents LED Indicators Per Device Power Perron RING AAO GRAPEOE Package includes the following Performance Specifications m Dyna Switch 16 or 24 an ep Oe Eras DESH a Rackeieunting brakes Transmission Method Store and forward MAC address table 8k entry MAC address table Raia y m Four 4 adhesive backed rubber feet Maximum Forwarding Rate 14 880 pps 10Base T ea ee 64byte packets 148 800 pps 100Base TX i i Maximum Filtering Rate 14 880 pps 10Base T m means 64byte packets 148 800 pps 100Base TX Flow control Back pressure half duplex EEN sane Pause frame full duplex SS Duplex mode Supports both Half duplex and al Full duplex mode Dyna Switch 16 or 24 AC power cord rubber feet User s Guide Physical amp Environmental Specification Power Supply 100 240V AC 50 60Hz Internal universal
5. s and 100Mbps Ethernet networks The Switches are targeted at workgroup department or backbone computing environments in SME small medium enterprise businesses These Switches provides auto sensing 10 100Mbps Ethernet RJ 45 ports which automatically detect the speed of the device that you plug into them This switching function allows LOMbps 1OOMbps Full duplex and Half duplex devices to communicate on the same network without having to replace any infrastructure This flexible feature allows your network a timely economical migration to LOOMbps Fast Ethernet Key Features Automatic MDI MDIX crossover for all ports N Way Auto negotiation for 10 100Mbps transmissions Store and Forward switching architecture Auto detection of full half duplex mode in all ports Performs non blocking full wire speed 8k entry MAC address table LED indicators for Power Link activity and Full Duplex Collision 19 Rack mountable with included brackets Conforms to IEEE 802 3 802 3u and 802 3x standard Wear For full coverage of your warranty be sure Product to register your product using the enclosed Warranty registration card Troubleshooting The Switch can be easily monitored through panel indicators to assist in identifying problems This section describes common problems you may encounter and possible solutions E Power If the power indicator does not light when the power cord is plugged in you may have a problem with the po
6. wer outlet or cord However if the power LED goes off after running for a while check for loose power connections power losses or surges at the power outlet Turn off power wait 30 seconds and turn power on again If problem is still not resolved call for dealer s assistance m Cabling Verify that the cabling type is correct Make sure all cable connectors are securely seated in the required ports Use only standard Unshielded Twisted Pair UTP Category 3 4 5 or 5e cables Use only Category 5 or 5e when connecting with Fast Ethernet Make certain the maximum distance between the Switch and what it s connected to is 100 meters or less NOTE Do not plug a standard telephone cord into an RJ 45 port This may damage the switch Product Specifications General Specifications Standard IEEE 802 3 10Base T Ethernet Compliance IEEE 802 3u 100Base TX Fast Ethernet IEEE 802 3x Flow Control and Back pressure IEEE ANSI IEEE 802 3 N way Auto negotiation Protocol CSMA CD Ports 10 100Mbps Auto sensing RJ 45 ports with Auto MDI MDIX crossover Data Transfer Rate Ethernet 10Mbps half duplex 20Mbps full duplex Fast Ethernet 1OOMbps half duplex 200Mbps full duplex Segment Bridge For enterprise networks where large data broadcasts are constantly processed these switches are an ideal solution for department users to connect to the corporate backbone In the illustration below two Ethernet switches with PCs print