1. 5 Apply even pressure on the corners of the N FXE NIC card pushing down until it seats firmly into the PCI E slot Tech Support 1 800 260 1312 International 00 1 952 941 7600 24 hours Install the N FXE NIC card continued 6 Replace the PC or File Server cover and secure it with the screws removed in Step 2 7 Disconnect any antistatic devices 8 Power up the unit Network remote boot configuration Select remote boot type To enter the MBA configuration menu to select remote boot type PXE RPL press SHIFT F10 keys within 3 seconds after powering up the PC otherwise the computer will load the OS Set network remote reboot To set the network remote boot enter PC BIOS first and then select the Boot tab after that choose MBA as the priority Cancel network remote boot To cancel network remote boot change the PC BIOS setting for MBA to Hard Drive or devices Wake on LAN WoL The WoL function on this NIC can recognize a wake up frame and signal the PC to power up The default state of the WoL function is enabled ON which means pin 2 and pin 3 on J1 3 pin header are connected via a jumper as shown below O OFF Wake on LAN select Jumper J techsupport transition com Click the Transition Now link for a live Web Chat 3 N FXE Series Fast Ethernet NICs Cable Specifications Fiber cable Bit error rate Single mode fiber recommended Multimo
2. Cable Specifications 4 Technical Specifications Troubleshooting 44 42 064 44 6 Comact US 242224524456 eeeues 7 N FXE Series Fast Ethernet NICs Installation Checklist Before installing the Fast Ethernet N FXE Series 100Base FX Fiber NIC verify that the package contains the following items e Fast Ethernet N FXE Series 100Base FX Fiber NIC e LAN Driver and User s Guide CD ROM Please notify your sales representative immediately if any of the aforementioned items is missing or damaged Description The two LED indicators LINK ACT and FDX located on the bracket show network board link activities and full duplex statuses See Figure 1 aS Se S LEDs N FXE NIC card installation CAUTION Wear a grounding strap and observe electrostatic discharge precautions when installing the N FXE NIC Failure to observe this caution could result in failure or damage of the N FXE module WARNING Turn power OFF before installing the N FXE NIC To install the N FXE module do the following Turn OFF power to the PC or file server and unplug the power cord 2 Remove the cover from the PC or file server keep all screws Select an empty PCI E slot see system documentation if not sure where the PCI E slots are located and remove the faceplate Keep the faceplate 4 Remove the network N FXE NIC from the shipping package and store the packaging material in a safe place
3. link FLASHING activity on link FDX full duplex link ON full duplex link Data transfer node speed Full duplex with NWay flow control 100Mbps speed Software support e Windows 2000 2003 XP NT4 0 Vista e Novell Netware 4 x e Linux e NDIS2 e PXE amp RPL Boot ROM Bus Slot PCI E 1 0 compliant PCB dimensions 120 L x 68 5 H mm 4 72 L x 2 7 H Weight 0 06kg 0 1 lb approximate Power requirements 3 3VDC 85A Power consumption 3 watts Ambient temperature 0 C to 50 C 32 F to 122 F Humidity 5 to 90 non condensing Warranty Lifetime WARNING Visible and invisible laser radiation when open DO NOT stare into the beam or view directly with optical instruments Failure to observe this warning could result in damage to your vision or blindness CAUTION Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure Electronic emission notices This equipment has been tested and found to comply with the limits for a class B computing device pursuant to Subpart J of part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment This equipment has been tested and found to comply with the protection requirements of European Emission Standard EN55022 EN61000 3 and the Generic European Immunity Standard EN55024 The information in this manual is subject to chang
4. On TRANSITION USER S GUIDE N FXE xxx 01 00Base FX Fiber Adaptor NIC Cards PCI Express xI Interface eAvailable with SC ST LC multimode and single mode fiber connections Wake on LAN WoL Supports 802 1q VLAN tagging 100Base FX Fiber Adapter NIC is a Fast Ethernet NIC that fully complies with all IEEE 802 3u and 100Base FX standards Two LED indicators LINK ACT and FDX on the bracket will help to oversee board link activities and full duplex status Fast Ethernet PCI E 100Base FX Fiber adapters support Preboot Execution Environment PXE Remote Program Load RPL and Bootstrap Protocol BOOTP Multi Boot Agent MBA is a software module that allows your networked system to boot with the images provided by remote systems across the network Part Number Fiber Port N FXE ST O1 ST 1310 nm multimode 2km 1 2 miles std low profile bkt PXE boot included N FXE SC 01 SC 1310 nm multimode 2km 1 2 miles std low profile bkt PXE boot included N FXE LC 01 LC 1310 nm multimode 2km 1 2 miles std low profile bkt PXE boot included N FXE SC5 01 SC 1310 nm single mode 5km 3 miles std low profile bkt PXE boot included N FXE LC5 01 SC 1310 nm silngle mode 5km 3 miles std low profile bkt PXE boot included Typical maximum cable distance Actual distance is dependent upon the physical characteristics of the network installation Installation 4 tan og dace 2
5. de fiber recommended Multimode fiber optional N FXE ST 01 Fiber optic transmitter power Fiber optic receiver sensitivity Link budget N FXE SC 01 Fiber optic transmitter power Fiber optic receiver sensitivity Link budget N FXE LC 01 Fiber optic transmitter power Fiber optic receiver sensitivity Link budget N FXE SCS5 01 Fiber optic transmitter power Fiber optic receiver sensitivity Link budget N FXE LCS5 01 Fiber optic transmitter power Fiber optic receiver sensitivity Link budget lt 10 9 9 um 62 5 125 um 100 140 85 140 50 125 um 1310 nm multimode min 19 0 dBm max 14 0 dBm min 31 0 dBm max xx 0 dBm 12 0 dB 1310 nm multimode min 19 0 dBm max 14 0 dBm min 31 0 dBm max 14 0 dBm 12 0 dB 1310 nm multimode min 19 0 dBm max 14 0 dBm min 32 0 dBm max 14 0 dBm 13 0 dB 1310 nm single mode min 20 0 dBm max 0 0 dBm min 32 0 dBm max 14 0 dBm 12 0 dB 1310 nm single mode min 20 0 dBm max 0 0 dBm min 32 0 dBm max 0 0 dBm 12 0 dB The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC 825 CDRH standard and comply with 21CRF1040 10 and 21CRF1040 11 Tech Support 1 800 260 1312 International 00 1 952 941 7600 24 hours Technical Specifications For models N FXE xxx 01 Standards IEEE 802 3u IEEE 802 3x IEEE 802 1q VLAN Data rate 100Mbps fiber media LED LINK ACT on the bracket ON communication
6. e without further notice techsupport transition com Click the Transition Now link for live Web chat N FXE Series Fast Ethernet NICs Troubleshooting Diagnostics LEDs and Boot ROM LEDs LED Color Function LINK ACT Green Lit when cable connection is good and speed is at 1OOMbps Blinks when any traffic is present FDX Green Lit when full duplex mode is active Name of Mfg Model Part Number Regulation Purpose ANA TRANSITION Declaration of Conformity CISPR22 2 2002 Class B EN55022 EN61000 CE Mark IEC61000 4 2 2001 IEC61000 4 3 2002 IEC61000 4 4 2001 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 U S A N FXE xxx 01 Network Interface Cards N FXE ST 01 N FXE SC 01 N FXE LC 01 N FXE SC5 01 N FXE LC5 01 EMC Directive 89 336 EEC To declare that the N FXE xxx 01 to which this declaration refers is in conformity with the following standards and Standard s a e EE OTE February 2009 Stephen Anderson Vice President of Engineering Date Tech Support 1 800 260 1312 International 00 1 952 941 7600 24 hours Contact Us Technical support Technical support is available at techsupport transition com e US and Canada 1 800 260 1312 24 hours e International 00 1 952 941 7600 24 hours Trans
7. erence at the user s own expense Canadian regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European regulations Caution This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der Funkstorgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst 6rungen auftreten In diesem F ll ist der Benutzer f r Gegenma nahmen verantwortlich Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilsateur de prende les measures sp cifiques appropri es In accordance with European Union Directive 2002 96 EC of the European Parliament VX and of the Council of 27 January 2003 Transition Networks will accept post usage W e returns of this product for proper disposal The contact information for this activity can be E found in the Contact Us portion of this doc
8. ition now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web based seminar Transition networks provides seminars via live web based training Log onto www transition com and click the Learning Center link Email Ask a question anytime by sending an email to our technical support staff techsupport transition com Address Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 U S A Telephone 952 941 7600 Toll free 800 526 9267 Fax 952 941 2322 techsupport transition com Click the Transition Now link for live Web chat N FXE Series Fast Ethernet NICs Compliance Information CISPR22 2 2002 Class B EN55022 EN61000 CE Mark IEC61000 4 2 2001 IEC61000 4 3 2002 IEC61000 4 4 2001 FCC regulations This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interf
9. ument CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE Fa PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes an ein ffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verst sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformit t Trademark notice All registered trademarks and trademarks are the property of their respective owners Copyright restrictions 2004 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A Manual Part Number and Rev 33429 B