1. 1 to 8 Spectra Options 1 to 2 Automatic Printing of Zone Status Each section represents 8 zones i e 002 zones 1 8 013 zones 89 96 The Printer Module must be assigned to the same partition as the zone Automatic Printing of Event Groups EVO 1 Miscellaneous Events 2 Arming Disarming Events 3 Alarm and Alarm Restore Events 4 Tamper and Tamper Restore Events 5 Trouble and Trouble Restore Events 6 Special Events 7 Access Events Fire Reset Contact Module Access Remote Access PC Fail To Com User Code Entered Bypass Programmed Delay before Transmitting and Utility Key Pressed Cold Start Warm Start Test Reports WinLoad Login Logout Installer In Out Access Granted Denied Request For Exit Door Left Open Alarm Door Left Open Restore Door Forced Alarm Door Forced Restore Spectra 4 Arming Disarming Events 5 Alarm amp Alarm Restore Events 6 Tamper amp Tamper Restore Events 7 Trouble amp Trouble Restore Events 8 Special Eventst see below for Special Events t PG amp FNC1 keys pressed Button Pressed on Remote Bypass Programming User Activated PGM Breaching Zone with Delay and System Power Up Enable Parallel Port EVO Option 1 Spectra Option 4 Printer Status Mask Options EVO Spectra 3 5 Off Line Status Mask 4 6 Paper Empty Status Mask 5 7 Printer Fault Status Mask 6 8 Printer Busy Status Mask If the Printer
2. Entering EVO Programming Entering Spectra Programming EVO Spectra Sections Sections S PE CTR amp EWO 1 Hold 0 key INSTALLER CODE 1 Press the ENTER key 2 Enter section 953 DGP 848 4003 EVO 2 Enter the INSTALLER CODE Printer Module V1 1 3 Enter module s 8 digit SERIAL NUMBER 3 Enter 3 digit SECTION you wish to program Enable Serial Port APR PRT3 4 Enter SECTION and enter the required DATA 4 Enter the required DATA Option 1 innin i The Printer Module can use the HyperTerminal communication program that otitis E nainn baup N x a ma E E Cc U R I Y 3 Printed in Canada 06 2007 nara com APRPRT3 El00 Introduction The Printer Module APR PRT3 provides the ability to automatically print live or stored events Sample Printout 2007 06 12 07 17 Partition 1 Arming with master John Doe 2007 06 12 18 09 Partition 1 Disarming with master John Doe Home Automation Interface Capabilities When used with an EVO Series or DGP 848 V4 11 or higher control panel the Printer Module can also be used as an interface between a home automation system and your control panel For information on this feature and its related programming sections refer to the ASCII Protocol Programming Instructions and or C Bus Programming Instructions available on our website at paradox com Technical Specifications Parallel Port Minimum 80 c
3. K Baud Settings Baud Rate Settings Option 2 3 Both the Printer Module and serial port should have the same baud rate Refer to the printer s instruction manual OFF ON 19200 Baud for the correct baud rate ON ON 57600 Baud Serial Port Usage Option 4 Set the Printer Module s serial port usage to either Event Reporting off or Home Automation on For information on using the Printer Module as an interface for a home automation system refer to the ASCII Protocol Programming Instructions and or C Bus Programming Instructions available on our website at paradox com Manual Event Group Printing The event groups are represented by the following sections a r Group Group Miscellaneous Evens t027 1028 T0291 10307 Arming Disarming Events 1081 10321 t0331 10341 MarrvAlarm Restore Events 10351 _ 10361 10371 10381 Tamper Tamper Restore Events _ 10391 1040 roar 10421 TroubleTrouble Restore Events 10431 10441 10451 10461 Special Events ioa roae t0401 10507 Access Eves rosi 10821 10531 10541 Mevens ossy ose 10571 1056r Each group of sections from 027 to 058 represents event groups that can be printed when a specified action from the PGM Programming Table occurs see the control panel s programming guide Event Groups 000 to 055 can be used to program the Printer Module s Manual Printing feature Event groups 062 and 063 can only be used when usi
4. Status Mask Options are ignored printer troubles will not be displayed These options apply only to the parallel port Setting the Date Spectra After a power failure the date must be reprogrammed Setting the Time Spectra After a power failure the time must be reprogrammed comes installed with Windows Using HyperTerminal the Printer Module will display events as they occur on your computer s monitor 1 Click Start from the Windows taskbar gt Programs gt Accessories gt Communications gt HyperTerminal The Connection Description window is displayed Enter a name in the Name text box and select an icon for your connection file Click OK The Connect To window is displayed From the Connect Using drop down list select the COM port connected to the Printer Module Click OK The COM Properties window is displayed Click on the Bits per second drop down list and select the baud rate that is set in the Printer Module Section 016 Options 2 amp 3 By default HyperTerminal sets the Data bits at 8 the Parity at None and the Stop bits at 1 Click OK The HyperTerminal display will appear already connected to the Printer Module Click on the Properties icon or select Properties from the File menu The communication file s Properties window is displayed Click the Settings tab Under Emulation verify that it is set as Auto Detect If not select Auto Detect from the drop down list Click O
5. er Module s 9 pin serial port to a home automation module 5 9 pin Serial Port Connect C Bus to the Printer Module using a null modem cable 6 9 pin Serial Port Connect either the Printer Module s USB or 9 pin serial port to a computer s COM port to view the control panel s events on the computer s monitor The events display on the monitor can then be printed through the printer connected to the computer A Remove AC power and battery before adding a module to the system Please refer to the control panel s Reference amp Installation Manual for the maximum allowable installation distance Only one APR PRTS3 can be connected per Spectra control panel Ls Printer cable length must not exceed 25ft Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www paradox com terms Your use of the Paradox product signifies your acceptance of all warranty terms and conditions 2007 Paradox Security Systems Ltd All rights reserved Specifications may change without prior notice One or more of the following US patents may apply 7046142 6215399 6111256 6104319 5920259 5886632 5721542 5287111 5119069 5077549 and RE39406 and other pending patents may apply Canadian and international patents may also apply Spectra Digiplex and EVO are trademarks or registered trademarks of Paradox Security Systems Ltd or its affiliates in Canada the United States and
6. ng an EVO control panel Paradox Memory Key Not To BE USED WITH UL LISTED SYSTEMS The Paradox Memory Key can copy the programmed contents of one APR PRT3 into as many others as needed For more information see the control panel s programming guide EVO Spectra 090 902 Copy to Memory Key 080 900 Paste to APR PRT3 When the APR PRT3 emits a confirmation beep wait for a second confirmation beep and then remove the Memory Key Press the PRINT TEST I P R D 0 X APR PRT3 sor _ switch to perform a e O ti 4 pid a Prarie Mi paradon com vin Y 6 ag print test o 7 O O To Control Panel a PANEL BUS ee I O EE ERROR EA am me ZZ fe B 1 co 1i S ce l TY wee i hn PIN SERIAL PORT o O DB 9 Serial Port Pin Out Diagram z SS Pin 4 DTR Data Terminal Ready Not Used M 4 Automation Module Pin 8 CTS Control Transmission Not Used Pin 3 TX 5 C Bus PC Interface Pin 2 RX Not Used in Event Reporting EVO control panels only 1 See LED Feedback on page 1 2 25 Pin Parallel Port Connect the Printer Module s 25 pin parallel port to any dot matrix printer Note The dot matrix printer must support a minimum of 80 columns 3 9 Pin Serial Port Connect the Printer Module s 9 Pin serial port to a dot matrix printer Note The dot matrix printer must support a minimum of 80 columns 4 9 pin Serial Port Connect the Print
7. olumn printer Serial Port 1 start bit 8 data bit no parity and 1 stop bit 8N1 Input Voltage 9 16 Vdc Current Consumption 60mA maximum Serial Port Baud Rates 2400 9600 19200 or 57600 bps Event Buffer 2048 events Compatibility EVO48 EVO96 EVO192 DGP 848 or DGP NE96 control panel Spectra 1728 or 1738 control panel V2 0 or higher APR PRT3 can be used to replace a APR3 PRT1 When using the APR PRT3 with the EVO192 the first 96 zones will be recognized Printer Requirements Dot matrix inkjet or laser printers can be connected through one of your computer s COM ports to the Printer Module s serial port Events can be displayed and printed using communication software like Procomm Telix and HyperTerminal It is recommended that only dot matrix printers that support a minimum of 80 columns be connected directly to the Printer Module Only dot matrix printers can print individual events in real time LED Feedback Panel Bus ERROR AX TX ON OFF OFF Combus shorted GND or VCC No clock No data ON JOFF JON Wrong data Invalid combus address Too many modules OFF Reserved for future use Combus lines are reversed Clock in Green Data in Yellow FLASH OFF OFF Low power Eoen OR EE eee Serial Bus LED Condition RX Printer module is receiving information TX Printer module is sending information EVO Spectra Sections Sections Partition Assignment Digiplex Options
8. or other countries
Download Pdf Manuals
Related Search
Related Contents
Guide - BREPOLiS Use & Care Guide - Villa Villekulla Napoleon - VETUS.com manual LEIA ATENTAMENTE O MANUAL ANTES DE OPERAR ESTE Valueline VLCP59001I20 Dale Tiffany TW100888 Installation Guide Samsung Galaxy Fame Duos manual do usuário User Manual User Manual Newstar LCD/TFT desk mount Copyright © All rights reserved.