Home

Seiko 7T32 Watch User Manual

image

Contents

1. the P M period 2 When setting Minute hand advance it 4 to b minutes ahead of the desired time and then turn it back to the exact minute usijbu3 English ALARM O Alarmtime is set on a 12 hour basis ALARM hands move independently of MAIN TIME hands ALARM SETTING 1 Adjustment of ALARM hands e After the main time is adjusted follow the procedure below and then set the alarm The following procedure is necessary only after the main time is adjusted Hour hand Minute hand MAIN TIME MAIN TIME CROWN 2 ALARM minute hand hour hand 2 Pull out to second click Turn clockwise or counterclockwise to set ALARM hands to the current time MAIN TIME Push back in to normal position 2 Alarm time setting Once ALARM hands are adjusted to the main time alarm time setting can be made only by following the procedure below Pull out to first click v Press to set ALARM hands to 0 the desired alarm time v CROWN 2 back in to normal posi o ion X CROWN 2 NOTES When setting ALARM minute hand to the current time in H advance it 4 to 5 minutes ahead of the desired time and then turn it back to the exact minute Alarm hands move quickly if Button C is kept pressed If CROWN 2 is pulled out to first click within 1 minute after being pushed back in to normal position in the alarm sounds usi
2. 16 usijbu3 11 A 1 Standard measurement e A A WV START STOP RESET English 2 Accumulated elapsed time measurement 00 0 0 0 START STOP RESTART STOP RESET Restart and stop of stopwatch can be repeated by pressing Button A 3 Split time measurement 1 B 8 START SPLIT SPLIT STOP RELEASE 12 Measurement and release of split time can be repeated by pressing Button B RESET A B A B START FINISH TIME 2ND FINISH TIME RESET OF 1ST COMPETITOR OF 2ND COMPETITOR FINISHES COMPETITOR NOTES 1 If CROWN 1 is pulled out to second click STOPWATCH hands are reset to 0 position If CROWN 2 is pulled out to first or second click STOPVVATCH hands are reset to 2 0 position When stopwatch has been reset and Button A is pressed before the hands reach 0 position stopwatch still starts counting when Button is pressed 3 usijpug 13 English 14 TACHYMETER for models with tachymeter scale on the dial To measure the hourly average speed of a vehicle El Use the stopwatch to determine how many seconds it takes to go 1 km or 1 mile STOPWATCH second hand 40 seconds El Tachymeter scale indicated by STOPWATCH second hand gives the average speed per hour Tachymeter scale 90 90 tachymeter scale figure x 1 km or mile 90 km h or mph Tachymeter scal
3. Doo Cal 7732 INSTRUCTIONS P 3 INSTRUCTIONS P 24 INSTRUCCIONES P 45 BEDIENUNGSANLEITUNG S 66 ISTRUZIONI P 87 INSTRU ES P 109 130 You are now the proud owner of a SEIKO Analogue Quartz Watch Cal 7T32 For best results please read the instructions in this booklet carefully before using your SEIKO Analogue Quartz Watch Please keep this manual handy for ready reference Vous voici l heureux propri taire d une montre quartz analogique SEIKO Cal 7T32 Pour obtenir d excellentes performances de cet article SEIKO veuillez lire attentivement cette brochure que vous conserverez pour toute r f rence ult rieure Enhorabuena por su adquisici n de un reloj SEIKO anal gico de cuarzo Cal 7T32 Para ptimo resultado lea detenidamente las instrucciones de este folleto antes de usar el reloj Guarde este manual para consulta posterior Sie sind jetzt Besitzer einer SEIKO Analog Quarzuhr Kal 7T32 Bitte lesen Sie diese Bedienungsan leitung vor Verwendung der Uhr sorgf ltig durch und heben Sie sie gut auf Siete ora in possesso di un orologio SEIKO Analogico al Quarzo Cal 7T32 Per ottenere i migliori possibili risultati dal Vostro orologio leggere attentamente le istruzioni di questo manuale prima di utilizzare il Vostro orologio SEIKO analogico al quarzo Conservare poi il manuale stesso per ogni qualsiasi eventuale futuro riferimento Voc pode sentir se orgulhoso de possuir um Rel gio SEIKO
4. Quartz An logo Cal 7T32 Para obter os melhores resultados leia atentamente as instru es contidas neste op sculo antes de usar o seu Rel gio SEIKO Quartz An logo Queira conservar este manual para refer ncias futuras m Z A m un CONTENTS Page A 4 DISPLAY AND CROVMINS BUTTONS capi 5 DATE O HU 6 a 7 ALARM ns ano O E A 8 O er 11 TACHY METER St e E E OD e NR 14 ADJUSTING THE HAND POSITION iiss at oen ERA DENS SERERE es 16 RESETTING THE BU TaN Ossa Said 17 BATTERY LIFE INDICGA TOR 18 BATTERY CHANG UU MUT EET 18 TO PRESERVE TRE QUALITY OF YOUR WATCH soriana 19 O S P 23 English SEIKO ANALOGUE QUARTZ Cal 7732 FEATURES CZ TIME CALENDAR C2 STOPWATCH e Hour amp minute hands with small Measures up to 30 minutes in 1 5 second hand second increments O Date displayed in numerals e Can measure repeatedly up to 6 hours Cp ALARM O Can be set ona 12 hour basis with small alarm hands 2 TACHYMETER O For models with tachymeter scale DISPLAY AND CROWNS BUTTONS There are three buttons and two crowns m 5 o STOPWATCH minute hand STOPWATCH 1 5 second hand 2 Minute hand MAIN TIME Hour hand gt j A b MAIN TIME O lt Q 3 da
5. at the case crowns buttons gasket and crystal seal remain intact usijpug English 22 CHEMICALS Be careful not to expose the watch to solvents e g alcohol JA and gasoline mercury i e from a broken thermometer cosmetic spray detergents adhesives or paints Otherwise the case bracelet etc may become discolored deteriorated or damaged il PRECAUTION REGARDING CASE BACK PROTECTIVE FILM If your watch has a protective film and or a sticker on the case back be sure to peel them off before using your watch Otherwise perspiration getting in under them may rust the case back SPECIFICATIONS Frequency of crystal oscillator N Loss gain monthly rate 3 Accuracy of alarm 4 Operational temperature range D Driving SyYStem sucus iocos aci eun rns 6 Display system VITA RR o ROO 8 IC Integrated Circuit 32 768 Hz Hz Hertz Cycles per second Less than 15 seconds at normal temperature range 5 C 35 C 41 F 95 F 1 minute 10 C 60 C 14 F 140 F Step motor 4 pieces Three hands Hour minute and small second hands Displayed in numerals Minute and 1 5 second hands The stopwatch can measure up to 30 minutes in 1 5 seconds Small hour and minute hands The alarm is set on a 12 hour basis SEIKO SR927W 1 piece C MOS LSI The specifications are su
6. bject to change without prior notice for product improvement usijpug 23
7. e can be used only when the time required is less than 60 seconds Ex 2 If the measuring distance is extended to 2 km or miles or shortened to 0 5 km or miles and STOPWATCH second hand indicates 90 on tachymeter scale 90 tachymeter scale figure x 2 km or mile 180 km h or mph 90 tachymeter scale figure x 0 5 km or mile 45 km h or mph To measure the hourly rate of operation EE Use the stopwatch to measure the time required to complete 1 job El Tachymeter scale indicated by STOPWATCH second hand gives the average number of jobs ac complished per hour Ex 2 If 15 jobs are completed in 20 seconds STOPWATCH second hand 20 seconds Tachymeter scale 180 180 tachymeter scale figure x 1 job 180 jobs hour 180 tachymeter scale figure x 15 jobs 2700 jobs hour usijpug 15 ADJUSTING THE HAND POSITION If STOPWATCH hands will not return to the 12 o clock position when the stopwatch is reset or when the battery is replaced with a new one follow the procedure below English CROWN 1 CROIDN 1 Pull out to second click v Press repeatedly to reset STOPWATCH minute hand to the 12 o clock position P Press repeatedly to reset STOPWATCH second hand to 4 the 12 o clock position CROWN 1 Push back in to normal posi tion NOTES 1 Hands move quickly if the respective buttons are kept pressed 2 After adjusting the hand
8. he watch returns to normal temperature Pressure in bar is a test pressure and should not be considered as corresponding to actual diving depth since swimming movement tends to increase the pressure at a given depth Care should also be taken on diving into water We recommend that you wear a SEIKO Diver s Watch for scuba diving EH TEMPERATURES Your watch works with stable UE accuracy within a temperature 0 range of 5 C and 35 C 41 F and 95 F Temperatures over 60 C 140 F may cause battery leakage or shorten the battery life Do not leave your watch in very low temperatures below 10 C 14 F for a long time since the cold may cause a slight time loss or gain However the above conditions will be corrected when the watch returns to normal temperature SHOCKS amp VIBRATION Light activities will not affect your watch but be careful not to drop your watch or hit it against hard surfaces as this may cause damage E MAGNETISM Your watch will be adversely affected by strong magnetism Keep it away from close contact with magnetic objects ESA To prevent possible rusting of MAA OK the case and bracelet caused A by dust moisture and perspiration wipe them periodically with a soft dry cloth E PERIODIC CHECK It is recommended that the watch be checked once every 2 to 3 years Have your watch checked by an AUTHORIZED SEIKO DEALER or SERVICE CENTER to ensure th
9. jbug ALARM ENGAGEMENT DISENGAGEMENT e Alarm engagement e Alarm disengagement CROWN 2 Pull out to first click CROWN 2 Push back in to normal position English Designated Current time alarm time 3 gt Alarm Alarm disengaged NOTES 1 Alarm rings at the designated time for 20 seconds To stop it manually press Button A B or C or push CROWN 2 back in to normal position If CROWN 2 is pulled out to second click the designated alarm time is canceled with a warning beep 2 In that case set ALARM hands to MAIN TIME again push CROWN 2 back in to normal position and then pull it out to first click and set the desired alarm time again However if CROWN 2 is pushed back in to normal position before the warning beep stops the designated alarm time will not be canceled 10 STOPWATCH O Stopwatch measures upto 30 minutes in 1 5 second increments O After 30 minutes it will start counting again from 0 repeatedly upto 6 hours STOPWATCH OPERATION STOPWATCH 1 5 second hand STOPWATCH minute hand GROUND e Before using the stopwatch e Check that CROWNS 1 and 2 are set at normal position e Press Button B to reset STOP WATCH hands to 0 position If the hands do not return to 0 position follow the procedure in ADJUSTING THE HAND POSI TION page
10. position set the main time 16 RESETTING THE BUILT IN IC O Incase any ofthe hands should move improperly follow the procedure below to adjust the hand movement CROWN 1 1 Pull out to second click A M A AND Press simultaneously v uii 1 Push back in to normal posi ti ion NOTE Before using the watch again be sure to adjust the position of STOPWATCH hands and set the main time and alarm 17 English 18 BATTERY LIFE INDICATOR O Whenthe battery nears its end the small second hand moves attwo second intervals instead of normal one second intervals to indicate that the battery needs to be replaced with a new one Ifthe alarm is used while the second hand is moving at two second intervals the watch may stop operating Therefore if you see the second hand moving at two second intervals replace the battery with a new one as soon as possible BATTERY CHANGE The miniature battery which powers your watch should last approximately 2 2 years However because the battery is inserted at the factory to check Years the function and performance of the watch its actual life once in your possession may be less than the specified period When the battery expires be sure to replace it as soon as possible to prevent any malfunction For battery replacement we recommend that you contact an AUTHORIZED SEIKO DEALER and request SEIKO SR927W bat
11. s CROWN 1 Second hand MAIN TIME Date QU um 6 0 A e 9 CROWN 2 ALARM hour hand ALARM minute hand a Normal position b First click c Second click English DATE SETTING Pull out to first click Turn clockwise until the date for the previous day appears Pull out to second click and turn until the desired date appears Push back in to normal position NOTES Do not set the date between 9 00 p m and 3 00 a m Otherwise the date may not change properly f itis necessary to set the date during that time period first change the time to any time outside this period set the date and then reset the correct time It is necessary to adjust the date at the end of February and 30 day months TIME SETTING Hour hand Minute hand mm pa Y Second hand NOTES Pull out to second click when Second hand is at the 12 o clock position Turn to set Hour and Minute hands Push back in to normal position in accordance with a time signal 1 When setting Hour hand check that AM PM is correctly set The watch is so designed that the date changes once in 24 hours Turn the hands past the 12 o clock marker to determine whether the watch is set for the A M or P M period If the date changes the time is set for the A M period If the date does not change the time is set for
12. tery CAUTION Do not remove the battery from the watch If it is necessary to take out the battery keep it out of the reach of children If a child swallows it consult a doctor immediately TO PRESERVE THE QUALITY OF YOUR WATCH WATER RESISTANCE Condition of use Accidental Swimming Taking a bath Scuba Indication on contact with yachting and and shallow diving water such taking a and Degree as rain and shower saturation of water splashes diving resistance us 6uy sn Non water No indication resistant WATER RESISTANT o BAR WATER WATER RESISTANT 10 15 20 bar Yes Yes 10 15 20 BAR i English 20 O Non water resistant e f the watch becomes wet have it checked by an AUTHORIZED SEIKO DEALER or SERVICE CENTER O Water resistant 5 10 15 20 bar e Before using in water be sure the crowns are pushed in completely Do not operate the crowns and buttons when the watch is wet or in water If used in sea water rinse the watch in fresh water and dry it completely 10 15 20 bar WR When taking a shower with the water resistant 5 bar watch or taking a bath with the water resistant 10 15 or 20 bar watch be sure to observe the following Do not operate the crowns or push the buttons when the watch is wet with soapy water or shampoo f the watch is left in warm water a slight time loss or gain may be caused This condition however will be corrected when t