Home
        Schumacher 200.71990 Power Supply User Manual
         Contents
1.   Failure to follow instructions may cause damage or an explo   sion  Read the entire instruction manual before use  Always shield your  eyes during use and wear safety glasses     2     3 1  3 2  3 3    3 4    3 5    3 6    3 7    3 8    3 9       JUMP STARTER DC POWER SOURCE FEATURES    12V DC Power Outlet  ON OFF Power Switch  Digital Display    Per      Display Select Push Button  Switch    DFAT 5  Replaceable Jaw Battery  Clamps    6  Rubber Base    7  Internal Battery Charger  Outlet  not shown     DieHard     JUMP STARTING A VEHICLE    Warning  Failure to follow instructions may cause damage or an explosion   Read the entire instruction manual before use     Turn the ignition OFF before making cable connections   Use in a well ventilated area     Keep clear of fan blades  belts  pulleys and other parts that may cause  injury    Place the Jump Starter on a flat  stable surface near the vehicle battery  and away from moving engine parts     Make sure the rotary power switch on the front panel is in the O  OFF   position until clamps are connected to the vehicle battery  If plugged into a  110V AC wall outlet  disconnect     To prevent sparking  NEVER allow clamps to touch together or to contact  the same piece of metal     Clamp the red clamp     to the positive terminal of the battery   For a  negative grounded system        Clamp the black clamp     to an unpainted and unmoving part of the chas   sis or engine block  The 3 digit display will show the voltage of the bat
2.  PURCHASE    1 1    1 2  1 3    1 4    1 5    1 6    1 7    1 8    1 9    1 10    IMPORTANT  READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL     IMPORTANT SAFETY INSTRUCTIONS    Charge the internal battery immediately upon purchase  every 30 days  and after every use     Use in a well ventilated space     Contains a sealed  non spillable lead acid battery  Must be disposed of  properly    Someone should be within range of your voice or close enough to come to  your aid when you are working near a lead acid battery     Have plenty of fresh water and soap nearby in case battery acid contacts  your skin  clothing  or eyes  If acid enters the eye area  rinse with cold  water for at least 10 minutes and get medical help immediately     Do not smoke  or use matches or cigarette lighters  or allow any spark or  flame near the battery or engine     Never operate the power source unit if it has a damaged lead wire or  clamps  Have the lead wire replaced by a qualified technician     Wear complete eye and clothing protection when working with lead acid  batteries     Do not permit the internal battery in the jump starter to freeze  Never  charge a frozen battery     WARNING  Possible explosion hazard  Contact with battery acid may  cause severe burns and blindness  Keep out of reach of children     WARNING  Pursuant to California Proposition 65  this product contains  chemicals known to the State of California to cause cancer and birth de   fects or other reproductive harm     WARNING
3. DieHard    Jump Starter DC Power Source    pe       Model No   200 71990 220S  CAUTION     Read all Safety Rules and Operating Instructions   and follow them with each use of this product     Sears  Roebuck and Co   Hoffman Estates  IL 60179 U S A   00 99 000867 0109    TABLE OF CONTENTS  SECTION PAGE  IMPORTANT SAFETY INSTRUCTIONS 1  JUMP STARTER DC POWER SOURCE FEATURES  JUMP STARTING A VEHICLE    Oo N N    DIGITAL DISPLAY    CHARGING OF INTERNAL BATTERY WITH BUILT IN   3 AMP CHARGER     POWERING A 12V DC DEVICE  SPECIFICATIONS   TO ORDER AND REPLACE JAWS  STORAGE AND MAINTENANCE    O aa A O    DieHard One Year Full Warranty    When operated and maintained according to all supplied instructions  if this  DieHard product fails due to a defect in material or workmanship within one year  from the date of purchase  return it to any Sears store or other DieHard outlet in  the United States for free replacement     This warranty gives you specific legal rights  and you may also have other rights  which vary from state to state     Sears  Roebuck and Co   Hoffman Estates  IL 60179    FOR CUSTOMER ASSISTANCE OR REPLACEMENT PARTS   CALL TOLL FREE FROM 7 AM TO 5 00 PM CT  MONDAY THROUGH FRIDAY  1 800 SEARS 64  1 800 732 7764     CONTAINS SEALED NON SPILLABLE LEAD ACID  BATTERY  MUST BE DISPOSED OF PROPERLY     WARNING  Possible explosion hazard  Contact with    battery acid may cause severe burns and blindness   Keep out of reach of children        IMPORTANT  CHARGE IMMEDIATELY AFTER
4. d into the charger plug  on the left side of the jump starter   Extension cord not included  must be  purchased separately      Plug the extension cord into a 120V AC electrical wall outlet     CAUTION  Operating the Jump Starter while the internal battery is being  charged may cause permanent damage to the unit     Charging of the internal battery could take up to 48 hours due to the age  and condition of the battery  At full charge  the charger will automatically  drop into a float mode and maintain the battery at full charge without dam   aging the battery  The jump starter can be left plugged into the 120V wall  outlet indefinitely to maintain full power     NOTE  A fully charged battery will read 100     Recharge the jump starter after every use and every month  30 days  to  extend the battery life     If the charger is plugged in for over 48 hours and the battery does not fully  charge in this time  CHG ERR is shown on the Display  The batteries may  be getting old and will no longer accept a charge     POWERING A 12V DC DEVICE    This Jump Starter is a power source for all 12 volt DC accessories that  are equipped with a 12V accessory plug  The DC accessory outlet has  a 15 amp automatic overload protection circuit breaker  The breaker will  automatically reset after an overload occurs     To Operate a 12V DC Device     e Open the protective cover of the DC power outlet on the front panel of the  Jump Starter     e Plug the 12V DC device into the DC power outlet  and t
5. gged into a 120V AC  electrical wall outlet     e Unscrew the fastener securing the cables to the rear of the top jaw     e Unscrew the fasteners  2  securing the Copper Jaws to the plastic clamp   Remove the jaws and braided cable     e Reverse for assembly     9     STORAGE AND MAINTENANCE  IMPORTANT    e CHARGE IMMEDIATELY AFTER PURCHASE  e KEEP FULLY CHARGED     Charge the internal battery immediately upon purchase  every 30 days  and after every use     All batteries are affected by temperature  The ideal storage temperature is  between 40 and 70 degrees Fahrenheit  The internal battery will gradually  self discharge  lose power  over time  especially in warm environments   Leaving the battery in a discharged state may result in permanent battery  damage  To ensure satisfactory performance and avoid permanent dam   age  charge the internal battery every month     When the jump starter is ON  the clamps are live and will produce arcing  or sparking if they come in contact with each other  To prevent accidental  arcing  always keep the clamps on the storage holders and the JUMP  START ON OFF switch in the O  OFF  position when not using it to jump  start a vehicle     
6. isplay can be used to indicate a battery   s voltage when connected to  a battery or the percentage of charge in the jump starter   s internal battery     With the switch in the O  OFF  position  connect the clamps to the ve   hicle   s battery  and its voltage is displayed  Turn the jump starter   s rotary  switch to 12V  and the combination of both internal and external batteries  are shown     To read the internal battery   s charge status  disconnect the clamps from  the vehicle   s battery  with the switch in the O  OFF  position  press the  display button to read the percentage of charge left in the internal battery  or turn the switch to the 12V position  and the voltage level of the internal  battery is displayed  A fully charged battery will read 100  or 12 8 volts     CHARGING OF INTERNAL BATTERY WITH BUILT IN  3 AMP  CHARGER     IMPORTANT   e CHARGE IMMEDIATELY AFTER PURCHASE  e KEEP FULLY CHARGED     This Jump Starter comes with a sealed  non spillable DieHard mainte   nance free lead acid battery  This internal battery is specifically designed  to deliver high power jump starting as well as repetitive deep cycling  performance     After removing the jump starter from the package for the first time  charge  it for a minimum of 8 hours before using     To charge the Jump Starter internal battery     Make sure the rotary power switch on the front panel is in the O  OFF   position  ax    5 2    5 3    5 4    5 5    6 1    Plug at least an 18 gauge  AWG  extension cor
7. tery   Do not connect the clamp to the carburetor  fuel lines  or sheet metal body  parts  Connect to a heavy gauge metal part of the frame or engine block     If you have connected the clamps backwards  an audio alarm will sound   DO NOT turn your jump starter on  This could cause serious damage   Reverse the connections and the audio alarm will stop     a2    3 10    3 11    3 12    5 1    If no audio alarm sounds  turn the rotary switch to the 12V position  The  clamps are now powered  Crank the engine  If the engine does not start  within 5     8 seconds  stop cranking and wait at least 1 minute before at   tempting to start the vehicle again   This permits the battery to cool down      After the engine starts  turn the rotary switch to the O  OFF  position  Then  disconnect the black clamp     and then the red clamp     in that order   Store the clamps in the compartments located on the sides of the case     Recharge the jump starter as soon as possible after use      NOTE  In the rare case of jump starting a vehicle that has a positive   grounded vehicle electrical system  connect the NEGATIVE black clamp      to the negative terminal     of the vehicle battery  Then connect the  POSITIVE red clamp     to an unpainted and unmoving part of the vehicle  chassis or engine block  If you are unsure of the nature of the vehicle   s  electrical grounding system  check the owner   s manual of the vehicle  To  disconnect the clamps  reverse the order     DIGITAL DISPLAY    The d
8. urn the 12V DC  device    ON     if required     e If the 12V DC device draws more than 15A  the internal circuit breaker  of the Jump Starter will stop powering the device  If this occurs  unplug  the device and the circuit breaker will automatically reset after several  seconds    e The DC power outlet is wired directly to the internal battery  Extended    operation of a 12V DC device may result in excessive battery drain  Re   charge immediately after unplugging the device     12V DC Electrical Device Example Run Time Chart    Appliance Type Estimated Power Estimated  Time     Fluorescent Lights  Cellular Phones 4 Watts  Radios  Depth Finders  Fans 9 Watts     NOTE  Estimated run times  Actual time may vary  Times are based on  the internal battery being new  fully charged and operating at room tem   perature        7  SPECIFICATIONS    Internal Battery Type DieHard Maintenance Free AGM Lead  Acid    Nominal Voltage 12V DC  Capacity 22Ah    DC Power Outlet  Max  Continuous 15A  Load     Jumper Cables 4 Gauge 50 Inches Long  Battery Clamps Replaceable Jaw    Dimensions  H x W x D  16    x 14    x 5       Weight 22 Ibs        8  TO ORDER AND REPLACE JAWS    Part Number  2299001580  Description  Kit  Battery Clamp Rebuild  QTY Per Clamp  1   8 1 Battery Clamp Jaw Replacement    e Secure the clamp in an open position using a vise or equivalent clamping  device  IMPORTANT  Make sure the rotary switch on the front panel is in  the O  OFF  position and the jump starter is not plu
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
(取付方法  i-Qwik LITE Programming Guide 8-09.qxd  STR-485 スター分配器 仕様書  のたびは、闇仕切り開閉壁をお買い上げいただき、まことにありがとうご  30EM/EQ - Kälte Bast GmbH  Yamaha 1998 VMAX Owner's Manual  取扱説明書 - A`PEXi    PUBLICACIONES DEL ÁREA PROFESIONAL DEL COEIC Des de  User manual - Snooper Services    Copyright © All rights reserved. 
   Failed to retrieve file