Home
Samsung SCC-B535x(S) Security Camera User Manual
Contents
1. 6 Cut the 3 speed switch pull chain to a desired length optional Connect the wood pendant supplied to the 3 speed switch pull chain by sliding the wooden pendant small hole first onto the pull chain Attach the chain coupling to the end of the chain and allow the wooden pendant to fall down over the coupling RL Mig Bias THREE SPEED 1st Pull HIGH 2nd Pull Medium 3rd Pull Low 4th Pull OFF Using Your Ceiling Fan Restore electrical power to the outlet box by turning the electricity on at the main fuse box Check the operation of the fan by gently pulling on the pull chain switch All fans are shipped from the factory with the reversing switch positioned to circulate air down ward If airflow is desired in opposite direction turn your fan off and wait for the blades to stop turning then slide the reversing switch to opposite position and turn fan on again The fan blades will turn in the opposite direction and reverse the airflow Your fan model is equipped with a 4 position 3 speed pull chain switch The operating sequence is as follows WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of part
2. Figure 8 Repeat this procedure for other four blade assemblies WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades The blade flanges have an interlocking feature that must be fully engaged before tightening the screw Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again 11 BLADE me T ASSEMBLY gt ES D g Ro _ gt a a BLADE FLANGE SCREWS N _ Figure 8 12 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capa ble of withstanding a load of at least 50 pounds WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consul
3. property damage 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration Fan motor assembly One switch housing assembly Five fan blades One ceiling cover Five blade flanges One hanger ball downrod assembly One hanger bracket One coupling cover One loose parts bag containing 1 Sixteen 3 16 24 x 5 16 slotted Phillips blade screws Sixteen blade washers Eleven 1 4 20 x 1 2 Phillips oval head flange screws One wood pendant One coupling Three wire connectors Two threaded studs Two knurled knobs Two lockwashers One clevis pin One hairpin clip araoaroandow OOONDOSF oP NOTE Place the parts from the loose parts bags in a small container to keep them from being lost l any parts are missing contact your local retail er or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plas tic bag Place the fan assembly into the upper foam pad with the bottom of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly FAN MOTOR ASSEMBLY DOWNROD T SWITCH CUP ASSEMBLY E ASSEMBLY HANGER 8 BRACKET gt COUPLING COVER j See FAN BLADES FLANGES CEILING COVER SS HANGER BALL How to Put Your Ceiling 3 Make sure the
4. coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly 7 Remove the three switch housing mounting screws Figure 5 from the switch housing plate Position the switch housing assembly on the switch 4 housing plate and align the holes in the switch DOWNROD CLEVIS PIN MOTOR COUPLING 4a amp housing assembly with the holes in the plate Secure the switch housing assembly by installing the three screws Figure 6 A WARNING To avoid possible fire or shock do not pinch wires between the switch cup assembly and the switch cup plate Pans SWITCH HOUSI OR CONNECT NG MOTOR CONNECTOR 7 Jo gt I lt Figure 5 all SWITCH HOUSING ASSEMBLY Turn fan assembly upside down in preparation for mounting fan blade assemblies Mount blade flanges to fan blades using three 3 16 24 x 5 16 slotted Phillips blade screws and three blade washers Figure 7 Ris Mii 3 16 24 x 5 16 SLOTTED PHILLIPS BLADE SCREW 3 BLADE WASHER 3 S FAN BLADE BLADE FLANGE Figure 7 NOTE Take care not to scratch fan housing when installing blades NOTE Remove and discard the four shipping spacers and screws from the motor hub 10 Loosely attach one blade assembly to the motor hub using two 1 4 20 x 1 2 Phillips oval head flange screws Make sure the screws are NOT tightened
5. grommet is properly installed in the coupling cover then slide the coupling cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupling cover are both oriented correctly Figure 3 Fan Together 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in step 5 PIN HANGER BALL KA ii bhain Figure 1 SETSCREW 2 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the 4 Reinstall the hanger ball Figure 4 on the downrod downrod Remove the upper setscrew from the motor coupling Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew cou
6. 0750 35 760750 38 760750 40 760750 41 Consisting of 1 Hanger Bracket 2 Hanger Ball 3 Downrod Parts Bag Containing 761442 1 761442 761442 1 761442 1 761442 1 761442 761442 761442 761442 1 Wire Connector 3 a _ Pin Clevis Clip Hairpin Screw 1 4 20 x 1 2 11 Screw 3 16 24 x 5 16 Washer Head 16 10 Wood Pendant hreaded Stud 2 16 Lockwasher 2 ie a 4 17 Knurled Knob 2 18 Coupling 19 Blade Washer 16 5 Canopy Ceiling 760169 20 760169 16 760169 3 760169 760169 760169 23 760169 26 760169 31 760169 32 11 Wiring Harness 761947 1 761947 761947 1 761947 1 761947 1 761947 761947 761947 761947 1 12 Switch Housing 761919 8 761919 15 761919 6 761919 5 761919 5 761919 14 761919 2 761919 10 761919 16 13 Blade set of 5 761859 6 761859 13 761859 9 761859 22 761859 22 761859 12 761859 10 761859 18 761859 23 14 Flange set of 5 761901 8 761901 15 761901 6 761901 1 761901 5 761901 14 761901 2 761901 10 761901 16 20 Coupling Cover 761860 5 761860 15 761860 16 761860 761860 761860 17 761860 9 761860 1
7. 1 Owner s Manual BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER e PART DESCRIPTION NAME OF ITEM MODEL NUMBER For repair parts phone 1 800 654 3545 EMERSON ua Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Part No F40BP72230002 Printed in Taiwan 09 00 Form No BP7223 2
8. 4 CF755PW04 Hanger Ball Assembly 760750 760750 5 760750 30 760750 39 760750 29 760750 1 760750 36 760750 37 760750 24 760750 42 Consisting of Hanger Bracket Hanger Ball Downrod Parts Bag Containing 761442 761442 761442 761442 761442 1 761442 761442 2 Wire Connector 3 Pin Clevis Clip Hairpin Screw 1 4 20 x 1 2 11 Screw 3 16 24 x 5 16 16 Wood Pendant Threaded Stud 2 Lockwasher 2 Knurled Knob 2 Coupling Blade Washer 16 Canopy Ceiling 760169 2 760169 12 760169 14 760169 30 760169 19 760169 1 760169 24 760169 25 760169 15 760169 33 Wiring Harness 761947 761947 761947 761947 761947 1 761947 1 761947 761947 761947 2 761947 Switch Housing 761919 761919 13 761919 7 761919 3 761919 12 761919 1 761919 4 761919 11 761919 9 761919 17 Blade set of 5 761859 8 761859 11 761859 15 761859 24 761859 1 761859 8 761859 5 761859 16 761859 17 761859 17 Flange set of 5 761901 761901 13 761901 7 761901 3 761901 12 761901 1 761901 4 761901 11 761901 9 761901 17 Coupling Cover 761860 7 761860 13 761860 14 761860 6 761860 2 761860 10 761860 4 761860 1 761860 3 761860 12 Owner s Manual BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 BP7223 2 Model No Description CF755HTW04 CF755V04 CF755W04 CF755WPB04 CF755WW04 CF755H04 CF755S04 CF755BQ04 CF755AW04 Hanger Ball Assembly 760750 34 760750 15 760750 2 760750 3 760750 3 76
9. READ AND SAVE THESE INSTRUCTIONS Model No CF755AB04 CF755NWO4 CF7550B04 CF755PB04 CF755BK04 CF755TG04 CF755WW04 CF755H04 CF755S04 CF755WPB0O4 CF755DB04 CF755V04 CF755W04 CF755HT WO4 CF755BS04 CF755WB04 DE S G N E R CF755BQ04 CF755PW04 gs CF755AW04 Ceiling Fan Ow ner s Ma nual Net Weight 17 3 Lbs LIMITED WARRANTY What The Warranty Covers This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is As it applies to the motor this warranty will last for thirty years from the date you purchased your ceiling fan All other components and accessories are cov ered by this warranty for one year from the date you purchased your ceiling fan ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Company Do To Correct Problems Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor blade component or other accessory at no charge to you If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided Emerson will refund the actual purchase price of your fan We will ship the repaired product or replacement to you at no charge but
10. e grounded for safe operation 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire connectors supplied BLACK AND BLUE NOTE CEILING COVER GROUND FAN WIRES _ _OMITTED FOR CLARITY WIRE we LISTED WIRE WHITE SUPPLY CONNECTOR 3 NEUTRAL GREEN WIRE GROUND FROM HANGER BRACKET nee FAN GREEN WIRE BLACK SUPPLY GROUND FROM HOT Figure 12 HANGER BALL NOTE If you are using an Emerson Light Fixture with your fan see Light Fixture Owner s Manual for wiring Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 12 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 12 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result 3 Screw the two threaded studs s
11. ld create fan wobble hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed Reinstall the upper setscrew in the motor coupling Check that the lower setscrew is tightened securely Figure 2 NOTE The setscrews must be properly installed as described above or fan wobble could result It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are proper ly installed could result in the fan falling PIN WARNING BALLS It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling SETSCREW MOTOR COUPLING Figure 4 SETSCREW CLEVIS PIN 5 The fan comes with blue black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 6 Engage the connector of the switch housing assembly with the motor connector Figure 5 The two connectors are keyed and color
12. ned to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One stepladder One wire stripper One Phillips head screwdriver One 1 4 blade screwdriver Three wire connectors supplied MATERIALS Wiring outlet box and box connectors must be of type reguired by the local code The minimum wire would be a 3 conductor 2 wire with ground of the following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 A WARNING Before assembly your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experi ence have your fan installed by a licensed electrician Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted A WARNING Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or acces sories not designated for use with this product by Emerson Company could result in personal injury or
13. reasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when e The original purchaser or user ceases to own the product or e The fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Company REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Part No F40BP72230002 Form No BP7223 2 WARNING WARNING To avoid fire
14. s or acces sories not designated for use with this product by Emerson Company could result in personal injury or property damage A WARNING For your own safety turn off power at fuse box or circuit breaker before trouble shooting your TROUBLE Trouble Shooting PROBABLE CAUSE SUGGESTED REMEDY 1 Fan will not start Fuse or circuit breaker blown Loose power line connections to the fan or loose switch wire connections in the switch housing Reversing switch in neutral position Check main and branch circuit fuses or circuit breakers Check line wire connections to fan and switch wire connections in the switch housing WARNING Make sure main power is turned OFF Make sure reversing switch position is all the way to one side 2 Fan sounds noisy Blades not attached to fan Loose screws in motor housing Screws securing fan blade flanges to motor hub are loose Wire connectors inside switch housing rattling Motor noise caused by solid state variable speed control Screws holding blades to flanges are loose Attach blades to fan before operating Check to make sure all screws in motor housing are snug not over tight Check to make sure the screws which attach the fan flanges to the motor hub are tight Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the swi
15. shock and serious personal injury follow these instructions Safety Instructions Read your owner s manual carefully and keep it for future reference Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing Do not put anything into the fan blades while they are turning Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring must satisfy National and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly
16. t a qualified electrician if in doubt If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture A WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician How to Hang Your Ceiling Fan A WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 9 D AT LEAST 7 Figure 9 A WARNING The outlet box must be securely anchored and capable of withstanding a load of at least 50 Ibs 4 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt 1 Securely attach the hanger bracket to the outlet box using the two screws supplied
17. tch housing WARNING Make sure main power is turned OFF Some fan motors are sensitive to signals from Solid State variable speed controls If Solid State Control is used and motor noise results choose an alternative control method Tighten screws securely 3 Fan wobbles excessively Setscrew in motor coupling is loose Setscrew in hanger ball downrod assembly is loose Screws securing fan blade flanges to motor are loose Fan blade flanges not seated properly Hanger bracket and or ceiling outlet box is not securely fastened Fan blades out of balance Tighten both setscrews securely in the motor coupling Tighten the setscrew in the hanger ball downrod assembly Check to be sure screws which attach the fan blade flanges to the motor are tight Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together Tighten the hanger bracket screws to the outlet box and or secure outlet box Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation Repair Parts Repair Parts Listing Model No Description CF755AB04 CF755BK04 CF755DB04 CF755WB04 CF755NW04 CF755PB04 CF7550B04 CF755TG04 CF755BS0
18. upplied into the Maintena nce tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and IMPORTANT CARE INSTRUCTIONS turn until studs protrude through the holes in the for your Ceiling Fan ceiling cover Figure 13 Periodic cleaning of your new ceiling fan is the only 5 Secure the ceiling cover in place by sliding lockwash maintenance that is needed ers over the threaded studs and installing the two When cleaning use only a soft brush or lint free cloth knurled knobs supplied Figure 13 Tighten the to avoid scratching the finish knurled knobs securely until the ceiling cover fits snug ly against the ceiling and the hole in the ceiling cover is Abrasive cleaning agents are not required and should clear of the downrod Your fan is now wired to be be avoided to prevent damage to finish turned on and off from the fan switch _ CEILING COVER WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock THREADED STUD LOCKWASHERS 2 KNURLED KNOB Accessories Figure 13 1 Ceiling Fan Light Kits see store or catalog 4 WARNING 2 Ceiling Fan Light Controls see store or catalog To avoid possible fire or shock make sure that the 3 Downrod Extension Kits see store or catalog electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling
19. used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage WARNING To Reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use This Manual Is Desig
20. with the outlet box Figure 10 i ms ft EL Fin MR a I TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET Figure 10 TAB 2 Carefully lift the fan and seat the hanger ball down rod assembly on the hanger bracket that was just attached to the outlet box Figure 11 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 10 A WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall A WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard A WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket NOTE CEILING COVER a ne SUPPLY WIRES AND oi body FAN WIRES OMITTED ey he D ET FOR CLARITY bha HANGER BRACKET Figure 11 HANGER BALL DOWNROD ASSEMBLY How to Wire Your Ceiling Fan lf you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician 4 WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is ground ed contact a licensed electrician for advice as it must b
21. you are responsible for all costs or removal reinstallation and shipping of the product to Emerson Company How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Co 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request e To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Company e Use of parts or accessories not authorized by Emerson Company e Mishandling improper installation modifications or damage to your ceiling fan while in your possession or e Un
Download Pdf Manuals
Related Search
Related Contents
CM30B & CM60B 1 - Mitsubishi Electric Australia RUSH PAR 1 RGBW - User Manual OmniMount U2 Tilt Backtruss Curtain Animation 2m x 3m iiyama LCD 17 inch: ProLite E430S-W BLOOD PRESSURE MONITOR MANUALE D`USO PER BARBECUE A GAS GPL Copyright © All rights reserved.
Failed to retrieve file