1.                                                                      ILLES aR ADO BE    A                                                                                     Part 20    
2.      DISCONNECTING ALL CABLES   With the LCD panel turned to most backward position  the main I O  connector area will be easily accessible at bottom side of the main unit  Please  first note orientations of every existing cable connection and then  disconnect every cable properly before any further reconfiguration of cable  connections  Please note that the click lock spring has to be pressed down prior  to pulling out the connector such as the LAN port or the CR port or the  alternate RJ45 form COM3 port  Please also note that the fixing screws have to  be loosened free prior to disconnection such as the 2 regular DB9 form COM  ports or the VGA port  Please always hold the connector head instead of  pulling on the cable wire when disconnecting any connector  Failure to do this  could damage the cable and jack that 1s considered as an artificial destruction   Damages due to incorrect disconnection operation are not covered by  product warranty        Part 6    OPENING BASE BACK COVER    In order to settle the  touch terminal properly in a  point of sale system  all the  cable connections have to be  routed through its base   Therefore  please observe  the side view pictures of the base trunk at the left and release the triangle  marked hooks to remove the back cover     CABLE ROUTING IN BASE    For cable routing in the mini slim base   please refer to the picture at left  There is a cable  tie inside the base trunk as arrowed in the picture   Hold all the external cables wit
3.     5  one VGA port    6  one SATA data port plus one HDD power connector for optional  SATA HDD in base   7  one audio jack for stereo line output   8  one CR port capable of controlling 2 cash drawers max    9  one 2 pin type DC 12 V power input connector   10  reserved one LPT interface through use of optional special cable in    service window  Built in 1 internal 2W speaker  Touch control functions  left right button  double click  drag  amp  draw  Dynamic video memory technology up to 224 MB  Support high performance DDR2 SDRAM with maximum memory  size 2GB in two SODIMM  Integrated structure for side mount upgrade kit with software  programmable MSR parameters for Win XP or WEPOS  Accidental power off protection     The power switch located at a  recessed side of main unit is unlikely to be activated in normal  operation   Preconditioned power up function     by alarm clock or COM port  MODEM ring or LAN  Supports power saving by suspension mode    Option Items     Note  The underlined items in the following list means that option must be    a   b   c   d     e     set prior to shipment from the factory  The rest items can be set by the   dealers    DDR2 SODIMM memory expansion up to 2GB max    CF card reader in HDD bay  HDD in main unit will not be applicable    Base installation kit for HDD   Integrated side mount upgrade kit     lt  SD 680 with options of MSR and optical fingerprint sensor in USB  interface   Integrated base mount upgrade kit     lt  LCD Pole displa
4.    All brand and product names and trademarks are the property of their respective holders     P N  16590900010 Part 1    o    _    ALERT TO OUR HONORABLE CUSTOMERS     O Please always read thoroughly all the instructions and documents  delivered with the product before you do anything about it  Don   t  take any premature action before you have a full understanding of  the consequences      This product contains inside a Lithium battery  Please always  follow local environmental protection laws   regulations for disposal  of used batteries and always replace only with battery of same type     DAILY MAINTENANCE GUIDE    For regular cleaning of the KS systems  please use only soft haired  brush or dry soft cloth  You may use moist soft cloth to remove stains when  necessary  Apply only proper amount of mild neutral detergent for obstinate  stains  Please note that never use Acryl dissolving solvent or Polycarbonate  dissolving solvent  You may apply ammonia based glass cleaner only on the    screen surface  CAUTION    Risk Of Explosion If Battery Is Replaced By An Incorrect Type  Dispose Of Used Batteries According To Local Regulations    Part 2    o    Nh       INTRODUCTION  PRODUCT PICTURES    Front View Rear View       Side Views       Bottom View Inside Base       PARTS IDENTIFICATION    l     Ze  3   4    Main unit   Touch panel   LCD panel  Power indicator   Base stand    Part 3    Optional side mount kit   HDD cover   Hinge cover   Base back cover   9  Cable exit   10  
5.  When the KS 6812 system is turned off after a successful boot up  with external power continuously supplied  the preset automatic power on  functions will keep monitoring for the preset conditions and turn on the system  when the preset conditions are met    Please note that 1f the KS 6812 system 1s improperly turned off before  a complete boot up procedure  the above preset power on control functions will  be disabled until next turning off after a complete boot up     BRIGHTNESS CONTROL   At left side of the main unit  below the power switch  there are  brightness adjust push button  switches and two USB connectors   Each single press on the   or     button  changes the LCD panel display  brightness by a small amount  When  you press and hold the button the  change w  ll keep on until release or  extreme condition matched     USB PORTS    There are in total 6 USB ports for external connection  2 at left side  below power switch and LCD brightness adjust buttons  4 In I O area  All of  them comply to USB 2 0 standard        Part 12    o    CUSTOMER DISPLAY    Please follow the instructions on the manual that comes along with  the customer display when lt 1s installed     DISPLAY ISSUES  Main LCD Display    For best viewing result please set your display resolution at 1024 x  768 with high color    The system Video Memory is shared from system memory  The video  memory size is default 8 MB and can be set to be 1 MB     VGA Port  The VGA port in the KS 6812 system supports ei
6.  loss of  data or profits  resulting from the furnishing  performance  or use of this material    This information is provided    as is    and Posiflex Technologies  Inc  expressly  disclaims any warranties  expressed  implied or statutory  including without limitation  implied warranties of merchantability or fitness for particular purpose  good title and  against infringement    The information in this manual contains only essential hardware concerns for general  user and is subject to change without notice  Posiflex reserves the right to alter product  designs  layouts or drivers without notification  The system integrator shall provide  applicative notices and arrangement for special options utilizing this product  The user  may find the most up to date information of the hardware from web sites   http   www posiflex com or http   www posiflex com tw or http   www posiflexusa com  All data should be backed up prior to the installation of any drive unit or storage  peripheral  Posiflex will not be responsible for any loss of data resulting from the use   disuse or misuse of this or any other Posiflex product    All rights are strictly reserved  No part of this documentation may be reproduced   stored in a retrieval system  or transmitted in any form or by any means  electronic   mechanical  photocopying  or otherwise  without prior express written consent from  Posiflex Technologies  Inc  the publisher of this documentation       Copyright Posiflex Technologies  Inc  2009 
7. IDE channel 1 Master  device  The CF memory card reader inside main unit accepts a type II CF  memory card  Please note that usual utilities such as FDISK EXE or  FORMAT COM must never be used on CF card or permanent damage  can occur  If this option is installed  the standard SATA HDD in main unit is  not applicable     HDD  amp  SATA PORT    The 2 5    HDD in the main unit is connected to the system through  internal Serial ATA  SATA  connector  The optional HDD in the base unit if  installed is connected to the system through SATA port  The internal SATA  HDD will be detected as    Ch  0 M     and the HDD connected to the SATA port  will be detected as    Ch  0 S     in    Advanced BIOS Features     gt     Hard Disk  Boot Priority    of BIOS setup  Both IDE or SATA controller can be set to     Disabled    in    Integrated Peripherals     gt     OnChip IDE Device    of BIOS  setup when required     TOUCH PANEL    All paragraphs below are applicable for models with touch panel only   The user of those models without touch panel can ignore them and consider  this user   s manual ends here     Mouse Emulation   The touch panel in KS system uses USB interface  When the touch  driver is properly installed  this touch panel works exactly like a standard  mouse of USB interface  However  if the system is running under safe mode   most drivers are disabled in this mode and the touch panel calibration 1s  therefore not guaranteed  It 1s recommended to use a standard USB mouse or  ke
8. POUSIFLEX  KS   6812    _    Fan Free Touch Terminal    User   s Manual  Rev   Original       FCC Notes   This equipment generates  uses  and can radiate radio frequency energy and  if not  installed and used in accordance with the instructions manual  may cause interference  to radio communications  It has been tested and found to comply with limits for a Class  A digital device pursuant to subpart J of Part 15 of FCC Rules  which are designed to  provide reasonable protection against interference when operated in a commercial  environment  Operation of this equipment in a residential area is likely to cause  interference in which case the user at his own expense will be required to take whatever  measures to correct the interference    Warranty Limits    Warranty terminates automatically when any person other than the authorized  technicians opens the machine  The user should consult his her dealer for the problem  happened  Warranty voids 1f the user does not follow the instructions in application of  this merchandise  The manufacturer is by no means responsible for any damage or  hazard caused by improper application    About This Manual    Posiflex Technologies  Inc  has made every effort for the accuracy of the content in this  manual  However  Posiflex will assume no liability for any technical inaccuracies or  editorial or other errors or omissions contained herein  nor for direct  indirect   incidental  consequential or otherwise damages  including without limitation
9. Power switch   11  LCD brightness up button   12  LCD brightness down button   13  Base back cover hook   14  USB ports on left side   15  Sundries trough for pencils  paper clips etc   16  Rubber feet with fixing screws   17  Screw holes for base mount kit   18  Oval cable passage on cast base trunk  19  Cable tie for all cables   20  Screw posts for optional HDD in base    PRODUCT FEATURES    Standard Features    CPU  Intel Atom N270 1 6G   Fan free structure for harsh environment   Data storage device  SATA HDD 2 5    80 GB or optional CF card   reader adaptor  amp  CF card in main unit    An advanced mini slim base design that supports storage room for   optional 2 5    SATA HDD    Support WinXP Pro  WEPOS and Linux OS   High quality 12    TFT active matrix LCD panel   Vertical type LCD panel with easy tilt angle adjustment from 20   to   90     LCD brightness adjust buttons at side of main unit   Durable resistive type touch panel that endures 35 million touches min    at same spot   Various I O ports supported  including    1  3 serial ports with 2 in form of DB9 connectors and 1 in form of 10  pin RJ45 type modular connector  All are with capability for  5V  DC support    2  6 standard USB ports with 2 at side and 4 in I O area below panel   3  two internal proprietary USB ports for touch function and optional  side mount kit   4  one LAN port Ethernet 10 100 1000 Base T with LAN status  indicators on jack  green for link  orange for data transmission     E N    Part 4
10. This switch  controls the power on off of the system  This switch  turns the system on when pushed only when external  power is present  This switch turns the system off  when pushed again during power on status  However   if the system hangs due to any reason such as  software resource conflict a simple push on the  switch may fail to turn off the power  In this case   please utilize the forced power off feature by pressing the switch and holding  Part 11       z    for within 10 seconds   There must always be at least 10 seconds waiting before switching on  again once the system is powered off successfully     Automatic Power On Control   The system may also turn on according to some preset conditions  such as Modem Ring Up or Alarm Clock Wake Up or LAN Wake Up    To utilize Modem Ring Up or Alarm Clock Wake Up function  the  user should enter the BIOS setup by pressing    Del    key at system boot up   choose in    Power Management Setup    and make the    Power On by Ring     enabled for Modem Ring Up or enable the    Resume by Alarm    for Alarm  Clock Wake Up  Save the configuration and exit the BIOS setup program  The  Preset Power On Control will then be ready  For LAN wakeup  the item    PCI  Express PM Function    must be enabled in    Power Management Setup    and an  operating caller system connected through LAN to the system 1s required  It  also requires a qualified networking technician to check the LAN chip ID of  the system for the caller system to wake up   
11. h the cable tie   Have all cables to pass through the oval hole on  the trunk as triangle marked to come out of the  front side of trunk  Connect all the cable ends to  main unit  Should there is the option SATA HDD  in base installed  please double check that the  HDD cables must be still secured     BASE MOUNT UPGRADE KIT Luella    Pole Display   For the KS 6812 series with  mini slim base  the LCD customer  display PD 309 U or the VFD PD   2605 U can be attached to either rear  corner of base bottom  Refer to the  pictures at right  Use the 3 attached  screws to fix the metal base plate of the PD to bottom  plate of mini slim base at the circled positions  the  holes marked with    KS    on bottom plate of PD against  the holes marked    P    on bottom plate of KS system    Connect the interface cable to go into the base through  cable exit arrowed at right to the main unit                 Part 7    o    PREPARING THE MAIN UNIT    On the back of the main unit  there is a    service window facing the base trunk in most of MM  application  It is recommended to tilt the LCD panel  to most backward position and rest the surface of  LCD panel over a piece of soft clean cloth on a  desktop to access the service window  Use a screw     driver of adequate length to remove the service window a Window  lock screw to open the cover plate and find several Lock Screw  jumpers as illustrated in the lower right picture  The  jumpers in this window are mainly designated for  COM port powe
12. hout preloaded OS is highly discouraged  Posiflex shall not be  responsible for any technical support to questions arisen due to non preloaded  OS     Part 10    USING THE TOUCH TERMINAL  APPLICATION ENVIRONMENT    It is very important that you check the following operational  guidelines     Ventilation  This terminal must NOT be operated in an environment with  restricted ventilation  There must be at least 25 mm air clearance around any  top or side ventilation holes with a free flow of air around the unit at ALL  times for the installation     Operating Environment  The equipment must not be operated or stored in extremes of both  temperature and humidity moisture   Operating range 5  C to 40  C and up to  80  humidity     non condensing  max  wet bulb 26  C     Power Supply  The operating voltage range of the power adaptor should cover the  local power supply for proper operation  The power cable  the power outlet  and any power fusing arrangements must conform to local safety regulations   Please never do any connection   disconnection when system is still  powered on  Please always keep the external power adaptor in a free air  circulation     POWER ON OFF CONTROL    Power Indicator  There is a power indicator LED at center of lower rim of LCD panel   This LED lights up orange when external power is ready and turns to blue  when system power is turned ON     Hardware Power Switch   The power switch located at left side of the   main unit is a tactile pushbutton switch  
13. pite of  the fact that it is used in the way like an ordinary HDD  usual utilities such as  FDISK EXE or FORMAT COM shall never be used on CF Card  otherwise the boot sector of operating system itself may be damaged and  causing the CF Card no longer bootable    For KS 6812 systems preloaded with Windows XP Pro or WEPOS on  HDD  Posiflex provides recovery DVD delivered with the touch terminal for  the preloaded operating system  The System Integrator shall take care of  software restoration after OS recovered  A Posiflex supplied USB interface  COMBO drive will be required for such action  Other brand COMBO drive  may require its specific driver different from what supported in the recovery  DVD    Please use the recovery DVD in rescue operation only  Using it  otherwise may wipe out whatever stored in the HDD  All upgrade devices  drivers needed for manual installation in usual way are available in the  subfolder     drivers    in OS recovered HDD and the latest versions of these  required drivers will be available on our web  http   www posiflex com tw   Then follow instructions from your system integrator for software recovery     OPERATING SYSTEM INSTALLATION    This product is a highly professionalized equipment  The installation  of an OS into a machine without any preloaded OS could constitute major  difficulty for average user or obstacle by possibly unintentional negligence  even for PC veterans to accomplish such a task  Therefore  OS installation into  a system wit
14. r supply function  Please consult your  dealer for technical support on setup of these jumpers   Please note that only those qualified technicians may  adjust in the service window with information from  Posiflex and the contents in the service window may  change without notice as time develops  The option LPT  conversion cable should be applied to the connector as triangle marked in the  picture  Route the other end of the conversion cable through the oval opening  in base trunk and have the usual cable for parallel device connected     SIDE MOUNT UPGRADE KIT  OPTION     Remove the 2 screws circled in  the left picture to remove the cover for  side mount upgrade kit  Take out the  cable inside this cover and connect it to  the white connector inside the side  mount upgrade kit like SD 680 as  arrowed in the right picture  Gently  arrange the excessive length of this cable  back in the hole and screw fit it back to  the position originally occupied by the cover  Please  reserve the cover if there is chance to have the side mount kit removed in the  future           Jumpers       CONNECTING CASH DRAWER  OPTION     The RJ11 connector in main connection area of a KS 6812 system can  be used for controlling most of the common cash drawers available on the  market  However  it   s most recommended that the Posiflex CR 2000 or CR   2200 or CR 3100 or CR 3200 or CR 4000 or CR 4100 or CR 4210 or CR   6310 be used for best compliance     Part 8    o    The KS system will directly cont
15. riate connectors   Please make sure that each connector is connected to the correct port with the  correct orientation  Damages due to incorrect connection or orientation are  not covered by product warranty    Some connectors like the COM3 or LAN or CR connector have to be  gently inserted until a click is heard  It is recommended that connectors such as  the COM 1 2 and VGA connector be screwed into place once seated    Adjust the slack of each cable  Re adjust the tilt angle of the screen  for best viewing    Connect the cables to appropriate external devices through the cable  exit at the bottom of stand assembly  Please make sure that each connector has  to be connected to the right device in the right way    CAUTION  On doing any insertion or extraction of any connector  please  always hold the connector head itself instead of pulling on the  cable wire  Failure to do this could damage the cable and jack  that is considered as an artificial destruction and is not  covered by the warranty     Part 9    o    OPERATING SYSTEM RECOVERY    For KS 6812 systems with operating system in the Compact Flash  Card 1f the system 1s installed with the CF card reader  once the Compact Flash  is damaged for any reason  the thin client may fail to boot  A bootable new  Compact Flash Card will be required to have the workstation back to  work  Please follow instructions given by the System Integrator to deal with  situations like that  One more advice for CF Card application is that in s
16. rol the cash drawer using the cash  drawer port  CR  both to operate the opening mechanism and to monitor the  drawer open status  Both functions may be accomplished under software  control of the COMI serial port    Use the cable supplied with the cash drawer  Part No  21863018010   for connection to the CR port in KS system  This cable has a 6 pole plug at one  end and an 8 pole plug at the other  The 8 pole plug should be inserted into the  connector marked     signal cable from POS Printer    at the rear of the cash  drawer  The 6 pole plug should be inserted in the connector marked    CR     found in the main connection area in the system    The user may also purchase the optional 2 in 1 cash drawer control  cable  Part No  218630023800  to control 2 cash drawers In 1 port  It has a 6   pole plug at one end and two 8 pole plugs at the other  The 6 pole plug should  be inserted in the connector marked    CR    found in the main connection area in  the system  Each 8 pole plug should be inserted into the connector marked     signal cable from POS Printer    at the rear of one of the cash drawers  The  cable lengths for the two 8 pole plugs are different  Use the shorter one for the  original cash drawer    CR1    and use the longer one for the extended cash  drawer    CR2    that will be distinguished by the software command     CONNECTING CABLES    To have the re assembled main unit with stand assembly ready for  operation  please connect all required cables to the approp
17. ther a base mount  2  display or a separately connected LCD monitor or touch monitor  To  support the DC power to the 2    display monitor  have a qualified technician to  set an internal jumper in KS main unit to supply the required power through  the VGA connector according to Posiflex technical information  Do not  connect other monitor to this port before the power in this port is disabled     SERIAL PORTS   COM1 2 3    In KS 6812 system  there are 3 serial ports available  All can supply a   5 V DC through pin 9 after proper jumper setting change  COM1 2 ports are  standard RS232 serial ports as status at delivery  COM3 1s also set to standard  RS232 serial port as status at delivery if the option conversion cable is applied     PARALLEL PORT    In KS 6812 system  the parallel port can be available only through  use of the optional conversion cable  It should be connected to the special  connector inside the service window as described earlier  The other end of the  cable is the normal 25 pin D sub female LPT connector     AUDIO OUTPUT SPEAKER    The audio port in KS 6812 system is arranged to have an internal  audio speaker with maximum audio power of 2 W at lower left corner of the  main unit  The internal speaker will be automatically disconnected when a  plug is inserted in the line output jack     Part 13    o    CF MEMORY CARD READER    If the CF card reader is installed and the CF card is used for system  data storage device  it is recognized by the system as the 
18. y PD 309U or    lt V VFD Pole display PD 2605U   Wireless LAN adaptor in USB interface   Preload OS WinXP Pro  WEPOS or Linux   RJ45 to DB9 serial port conversion cable  for COM 3 port    Split cable for 2 cash drawer control  Part No  21863018010    LPT interface conversion cable    Part 5    o    INSTALLATION GUIDES    CAUTION  Before any installation or cable connection to the set  please  always make certain that the system is turned off and the  external power source to the set is removed to prevent electric  hazard  Never touch any metal pin in the connectors or  circuits to avoid high voltage hazard or electrostatic discharge  damage unless the operator is well grounded  Failure to do the  above will void the product warranty     TECHNICAL MANEUVERS    Applicable technical maneuvers in KS 6812 series include serial  COM port power supply settings  VGA port power supply setting  system  CMOS data reset  DRAM upgrades  physical access to CF memory card 1f the  CF card reader option 1s installed and installation of optional SATA HDD in  base  All these technical maneuver operations require purchase of applicable  Technical Manual from Posiflex or consultation from Posiflex authorized  dealers and should be handled only by a qualified technician     TILTING LCD PANEL    The tilting mechanism in KS 6812 series utilizes  hinges and there is no particular skill to turn the LCD panel to  most suitable angle for either viewing or convenience in cable  connection   disconnection
19. yboard in this mode    All the below mentioned mouse emulation functions can be  manipulated through relevant software  The system can give a beep and a click  on the left button of a mouse at the point when the touch panel is touched  If  the point touched is dragged across the screen surface  it works as the mouse  drag and drop feature  If the point is touched  released and touched within a  short time interval  it is double clicking left button of the mouse  To obtain the  effect like clicking on the right button of a mouse  touching any point on the  screen surface after touching the right click sticky button results as a click on  the right button of the mouse at that point     Part 14    o    Posiflex USB Touch Manager  A program named    Posiflex USB Touch Manager    and a right click  sticky button tool in the program group    Posiflex USB Touch Tools    is  installed in the preloaded Windows system with a USB interface touch panel  controller  This program can also be obtained by download from the  POSIFLEX web site     Part 15       Part 10                Part 17                Part 18                Part 19                POSIFLEX                         T31454                                                                                                                                                                                                                                                                                                                     
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
CS1768 / CS1788  Digitale Küchenwaage SKW 3 EDS A1  Philips HP6306  Samsung VP W 97 Camcorder User Manual  2004 Infiniti G35 Coupe/Sedan  VANTAGE 300 - Lincoln Electric  131-8190型 取扱説明書 ガスふろ給湯器 屋外設置形 16号全自動タイプ  1. Premere il pulsante [MENU]  D - Enter.ru  2016 OCTANE    Copyright © All rights reserved. 