Home

POSIFLEX Business Machines 5800G Computer Hardware User Manual

image

Contents

1. machine In preloaded Windows Posiflex Power Switch Manager in Posiflex Tools in the Program Files helps managing these functions Software Support The Jiva series provides a software power off command for application program maneuvers The Jiva also provides a specific means for the software to detect if the system is working on external or UPS battery power Due to this feature compatible software applications have the ability to change operating conditions when running on standard backup power The software programmer may take reference from the Jiva technical manual to apply such features Part 14 AUTOMATIC POWER ON There are several ways supported by this system to perform an automatic boot up as long as external power is supplied to the system Procedures for each method are described below By RTC Alarm preset 1 Preset the system to timely boot up by pressing Del key at powering up this system to enter system BIOS CMOS setup 2 Select Power Management Setup and enter PM Wake Up Events Go to item Power Up by Alarm and change the setting to Enabled 3 Alarm setup detail will appear Set the alarm as wished then press F10 key to save and exit CMOS setup 4 This system may be powered off and will automatically boot up at the preset alarm time By RS232 MODEM Ring up 1 Preset the system to boot up on RS232 MODEM ring by pressing Del key at powering up this system
2. all required cables to the appropriate connectors Please make sure that each connector is connected to the right port with the correct orientation Damages due to incorrect connection or orientation are not covered by product warranty Some connectors such as the LAN connector and the cash drawer connector have to be inserted until a click is heard It is recommended that connectors such as the external VGA connector the LPT port connector and the COM port connectors be screwed into place once seated If the COM1 port must be used the COMI terminator that occupies the COM1 port must be removed However when using the COM1 port be sure to use devices that provide proper hardware handshaking signals in order to keep the cash drawer control features A serial mouse is one example of a device that does not support handshaking Adjust the slack of each cable and close the cable cover Use the same plastic latchkey that is used when removing the cable cover but be sure to turn it in the clockwise direction to lock the cover in place Re adjust the tilt angle of the screen for best viewing SEPARATING MAIN UNIT Press the Lock Release button Push this way and slide the stand assembly z gt downward as viewed from the T a main unit to detach it from the main unit i gee A soft clean flat surface such as a piece of cloth on the desk In order to settle the touch terminal properly in a point of sale system all the cable
3. drag amp draw High resolution touch sensor 1024 x 1024 for Jiva TP only Dual display support per OS capability VGA memory size shared from system memory 8 64 MB Support high performance DDR266 DRAM with maximum memory size 1GB in two modules Integrated structure for optional security devices KP 100 SD 100 SD 200 or BC 100U Software programmable MSR parameters for Win 98 Win 2000 or Win SO ON Part 2 XP Pro Optional Items Note The underlined items in the following list means that option must be a b c d e h i set prior to shipment from the factory The rest items can be set by the dealers DDR266 SDRAM memory expansion up to 1GB Audio amplifier circuit and a pair of speakers in cable cover area Side mount upgrade kit among Deluxe security device upgrade KP100 covering keypad and option s from KB interface MSR smart card reader and finger print sensor Common security device upgrade SD100 covering option s from USB interface MSR or smart card reader and finger print sensor or iButton reader lt 2 in 1 security device upgrade SD200 covering options of USB interface MSR or optical scan type finger reader Bar code card reader BC 100U Integrated rear top mount LCD customer display PD 302 2 in 1 cash drawer control cable CCBLA 238 USB interface external slim type CD ROM drive UPS battery Preload OS Wall mount kit Part 3 INSTALLATION GUIDES CAUTION Befor
4. or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties express implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware concerns for general user and is subject to change without notice Posiflex reserves the right to alter product designs layouts or drivers without notification The system integrator shall provide applicative notices and arrangement for special options utilizing this product The user may find the most up to date information of the hardware from web sites http www posiflex com or http www posiflex com tw All data should be backed up prior to the installation of any drive unit or storage peripheral Posiflex will not be responsible for any loss of data resulting from the use disuse or misuse of this or any other Posiflex product All rights are strictly reserved No part of this documentation may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying or otherwise without prior express written consent from Posiflex Inc the publisher of this documentation Copyright Posiflex Inc 2004 All brand and product names and trademarks are the property of their respective hold
5. this touch controller driver certain display mode like full screen display of Windows DOS box should be avoided If for any reason the user wants to remove the driver for the RS232 touch controller please select MonitorMouse in the program list for removal Part 19
6. to enter system BIOS CMOS setup 2 Select Power Management Setup and enter PM Wake Up Events Go to item Ring Power Up Control and change the setting to Enabled then press F10 key to save and exit CMOS setup 3 Connect a RS232 MODEM to any of COM2 COM3 or COM4 and to a proper telephone line This system may then be powered off and will automatically boot up at the MODEM ringing By LAN Wakeup For LAN wakeup an operating caller system connected through LAN to the system to be called is required It also requires a qualified networking technician to check the LAN chip ID of the system to be called for the caller system to wake up DISPLAY RESOLUTION For best viewing result please set your display resolution at 1024 x 768 with high color In configuration of system memory max 64 MB can be shared as the video memory External LCD Monitor The external VGA port in the Jiva TP LT 5700G Jiva TP LT 5800G supports TM4115 touch monitor LM6112 LCD monitor or TM6112 touch monitor This port supports either mirror mode identical image or extended Part 15 m mode dual display function for Win98 or WinXP To support the DC power to these Posiflex monitor use the DC adaptor to connect into the monitor or VGA cable or purchase another type of VGA cable and set an internal jumper in Jiva TP LT 5700G or Jiva TP LT 5800G to supply the required power through the VGA connector SYSTEM PROTECTION In the Po
7. POSIFL Jiva TP LT 5700G s800G FEES Touch Control Work Station User s Manual Rev AO FCC Notes This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual may cause interference to radio communications It has been tested and found to comply with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures to correct the interference Warranty Limits Warranty terminates automatically when any person other than the authorized technicians opens the machine The user should consult his her dealer for the problem happened Warranty voids if the user does not follow the instructions in application of this merchandise The manufacturer is by no means responsible for any damage or hazard caused by improper application About This Manual Posiflex has made every effort for the accuracy of the content in this manual However Posiflex will assume no liability for any technical inaccuracies or editorial or other errors or omissions contained herein nor for direct indirect incidental consequential or otherwise damages including without limitation loss of data
8. PS 2 interface touch panel controller in Windows 98 touching the screen for a while followed by a slight move of the touch without leaving the screen surface will result in a right button mouse click Part 18 Posiflex Touch Terminal Manager A program named Posiflex Touch Terminal Manager is installed in the preloaded Windows system with a PS 2 interface touch panel controller This program can also be obtained by download from the POSIFLEX web site This program can be engaged in the program group Posiflex Tools and it controls the beep generated when the touch panel is touched the detail in right button click emulation and also provides touch panel re calibration RS232 Touch Controller If the Jiva TP 5700G or Jiva TP 5800G purchased is the leading edge Infra Red type touch models the touch panel uses an RS232 interface controller The Posiflex Touch Terminal Manager above should be disregarded In these models the COM4 position of the system will be covered in the connection area Removal of this cover will void the product warranty Once the RS232 touch controller driver is installed the user can utilize it to calibrate the touch screen define mouse button emulation modes enable right button emulation or define the click sound s tone and duration Please click Start Settings Control Panel and Elo Touchscreen or just click the elo icon in tool tray to engage this utility However with
9. ch panel All the serial ports can supply a 5 V DC through pin 9 after proper jumper setting change All 4 ports are standard RS232 serial ports as status at delivery When a serial Modem is to be used in Jiva TP LT 5700G or Jiva TP LT 5800G it is most recommended to use COM2 or COM3 port for this purpose In this way any hardware resource conflict is eliminated and the MODEM ring up function can be supported For Infra Red type touch control models it uses RS232 interface COM4 is occupied and covered Please never try to open the cover Otherwise the product warranty is voided Part 17 SOUND PORTS The audio port on Jiva TP LT 5700G Jiva TP LT 5800G supports a Microphone in and a line out jacks The internal audio output port supports line output signals and requires power amplifier for connection to speaker unless the option of audio amplifier and a pair of slim type speakers built in the cable cover area are ordered at the beginning LAN BOOT If the system integrator arranges the TP LT5700G to boot from a LAN server he may have revised the system BIOS installed in TP LT5700G to a specific program that depends on the LAN communication protocols involved In this case there will be a choice between LAN boot and local boot at boot up powering up process And it is advisable to select for LAN boot for this application and follow whatever the boot server defines TOUCH PANEL for TP models only All paragraphs below are applicabl
10. connections have to be routed through its base the stand assembly Therefore please press the lock release button at the rear side to separate the main unit from the stand assembly after all cables in cable cover disconnected For easy operation it is most recommended to lay the system facing down on front panel over a soft clean flat surface first such as a piece of cloth on the desk Press the button and slide the stand assembly downward as viewed from the main unit to detach the stand assembly away from the back of the main unit could then be an easier operation This approach can also be Part 5 applied when later on the main unit and the stand assembly have to be reunited OPENING STAND ASSEMBLY Take the adjustable stand assembly and turn it up side down to show the bottom of the base Now unscrew the 2 screws on the cable passage cover and take the cable passage cover away to show the cable passage If there is no need to install the optional UPS battery here please skip the next paragraph and start routing cables through the cable passage Cable Otherwise please remove the four Passage screws holding the battery cover to Cover install the battery Screws ae INSTALLING UPS BATTERY Place the optional UPS battery in the battery compartment shown below left Screw on the battery cover and route the battery cable through the base Please pay particular attention to the environment requirement for UPS battery in ne
11. e any installation or cable connection to the set please always make certain that the system is turned off and the external power source to the set is removed to prevent electric hazard Never touch any metal pin in the connectors or circuits to avoid high voltage hazard or electrostatic discharge damage unless the operator is well grounded Failure to do the above will void the product warranty OPENING CABLE COVER Please first push the lock release lever on the base backward to adjust the stand to the most horizontal position for ease of operation Push Meco ieee lever back and turn panel to most horizontal position Insert the tip of the latchkey into a latch hole on one side near bottom of the main unit Turn this key counterclockwise to the end Do the same on the opposite side Be sure to take the key out of the hole before doing next operation Turn Counterclockwise Then Take Out The Latchkey Then push the lock release lever on the base backward to adjust the stand to the most horizontal position for ease of operation Open the cable cover by pulling at the removal hollow Pull The Removal Hollow Toward The User Part 4 CONNECT DISCONNECT CABLES After removal of the cable cover the connector area will be accessible then Please disconnect every cable before separation of main unit and the adjustable stand assembly When later the main unit and stand assembly are to be re assembled for application please connect
12. e in TP 5700G and TP 5800G only The user of LT 5700G and LT 5800G can ignore them and consider this user s manual ends here Mouse Emulation The touch panel in Jiva TP 5700G Jiva TP 5800G uses either a PS2 interface or an RS232 interface When its driver is properly installed this touch panel works exactly like a standard mouse However if the system is running under safe mode due to a previous improper shutdown or for any other reason most drivers are disabled in this mode and the touch panel calibration may not coincide with the mouse pointer It is recommended that a standard USB mouse or keyboard be used in this mode All the below mentioned mouse emulation functions can be manipulated through relevant software The system can give a beep when the touch panel is touched and can respond as if the left button of a mouse is clicked at the point touched If the point touched is dragged across the screen surface it can respond as though it is using the mouse drag and drop feature If the point is touched released and touched within a short time interval it will simulate double clicking left button of the mouse To obtain the effect like clicking on the right button of a mouse touching any point on the screen surface after touching the right click sticky button results as a click on the right button of the mouse at that point can work for PS 2 touch controller type under Win2000 and WinXP and for RS232 touch controller under Win98 For the
13. ers P N 16280901020 Part 1 a b c d e g h i aD k D m n 0 p q r Standard Features CPU Celeron compatible C3 800 MHz or up for Jiva TP LT 5700G C3 1 0GHz for Jiva TP LT 5800G A base design supporting optional UPS battery storage Support Win98 Win 2000 Win CE Win XP Pro and Linux environment for Jiva TP LT 5800G Support Win CE NET on CF card or Linux LAN boot for Jiva TP LT 5700G High quality 15 TFT active matrix LCD panel Vertical type LCD panel with easy tilt angle adjustment from 18 to 87 Resistance type InfraRed type optional touch panel for Jiva TP only Long life touch panel that endures 10 million touches at same spot for Jiva TP only Spill proof water resistant structure allowing easy cleaning Easy maintenance construction Various I O ports supported including 1 one PS 2 KB port 2 one PS 2 mouse port 3 4 serial ports with capability for 5V DC support reduce to 3 ports if RS232 interface touch panel is used one parallel port 2 USB ports one LAN port 10 100 base T Ethernet one external VGA monitor port one Compact Flash memory card connector for Jiva TP LT 5700G only 9 one DC 12 V power input connector 10 one UPS battery connector 11 one CR port for control over 2 cash drawers max 12 audio ports 1 Microphone input and 2 optional slim type speakers Touch control functions for Jiva TP only left button right button for Windows OS double click
14. ew well charged battery indicates that leaving a battery connected without system power on for recharging for 10 days or more or even storing the battery unconnected for more than 9 months could degrade the battery capability A Part 12 well maintained battery can be expected to provide adequate service for 1 year Battery replacement In the power management circuit in this POS system there is a handy battery monitor feature to help user find out when an UPS battery should be replaced The battery monitor will always first measure and check the UPS battery to see if the UPS battery is already incapable of service or if there is any sign for the possible critical fault development in the battery before it allows the charging operation to the UPS battery Reason for such extra check is that indifferent recharging on a battery with some critical fault like micro short circuit will not only boost the fault development in and total failure of the battery but also can result in confusing system malfunction In the preloaded OS there is a built in utility Power Manager that will interface the UPS battery monitor status with user When a healthy UPS battery is added to an originally UPS function disabled system the Power Manager will enable the UPS function automatically However when battery monitor disables the battery charging as designed while the UPS function of the system is originally enabled in other words the UPS battery is found out of orde
15. is used in the way like an ordinary HDD usual system management utilities such as FDISK EXE or FORMAT COM shall never be used on CF Card otherwise the boot sector of operating system itself may be damaged and causing the CF Card no longer bootable For Jiva TP LT 5800G the operating system exists in the HDD Once Part 10 the software system on HDD collapses it is possible to restore the operating system onto a physically intact HDD with use of the Recovery CD that comes with the preloaded operating system Please follow the instruction from your system integrator for system software restoration Follow the instructions below for operating system recovery only if your system integrator does not advise otherwise For the Jiva TP LT 5800G preloaded with Windows XP Pro or Windows 98 on HDD Posiflex provides recovery CD delivered with the touch terminal for the preloaded operating system The System Integrator shall take care of software restoration after OS recovered A Posiflex supplied USB interface CDROM drive will be required for such action Other brand CDROM drive may require its specific driver different from what supported in the recovery CD Please use the recovery CD in rescue operation only Using it otherwise may wipe out whatever stored in the HDD All upgrade devices drivers needed for manual installation in usual way are available in the subfolder drivers in OS recovered HDD and the latest versions of these required drive
16. me out of the stand from the lower edge and won t get trapped by this mounting operation If later on you want to remove the main unit from the stand you ll have to press down the lock release button on back of the stand at the time lifting the main unit CONNECTING CABLES Connect the cables required to the appropriate connectors Please make sure that each connector has to be connected to the right port in the right orientation Some connectors have to be inserted till a click is heard such as the LAN connector It is recommended to screw on the connector once it is inserted such as the external VGA connector the LPT port connector and the COM port connectors Adjust the slack of each cable and close the cable cover Use the same latch key as when opening the cable cover but this time turn it clockwise on both sides to secure the cable cover on the main unit Adjust the tilt angle of the main unit for best viewing effect in the application CAUTION On doing any insertion or extraction of any connector please always hold the connector head itself instead of pulling on the cable wire Failure to do this could damage the cable and jack that is considered as an artificial destruction and is not covered by the warranty Part 9 WALL MOUNTING The major part in the wall mounting kit is a bracket as shown in the picture Screw the bracket against the wall for mounting the Jiva TP LT 5700G Jiva TP LT 5800G in the direction that the wider part
17. midity non condensing UPS Battery option General care The UPS battery is consumables beyond product warranty Please note the following to preserve its serviceability as long as possible When the equipment is to be powered off for more than few days please disconnect the battery from the system and reconnect it and turn on the system to recharge the battery for 1 2 hours every 3 months if the temperature is lower than 30 C Recharge for 1 2 hours every month if the temperature exceeds 30 C When an UPS battery is installed in this equipment the environment should keep below 30 C to protect the life of the battery Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smooth running of the system during intermittent or few minutes power failure and will be automatically recharged when system turned on with AC power presence However if the AC power outage is known to last for more than few minutes 3 8 min depending on loading it is advisable to turn off the system instead of using the battery up while repeatedly using it up or improper maintenance reduces the battery life dramatically Please be particularly reminded to disconnect the UPS battery if the system is to be left OFF for more than 7 days to prevent possible damage Please be alerted that a study on brand n
18. pid On Off Running at Not sequined flash low capacity Hardware Power Switch The power switch located at left side of the main unit is a slide type switch This switch controls the power on off of the system This switch turns the system on when slid downward only when external power is present The switch will always spring back to its original position when pressure is removed This switch turns the system off when slid downward again during power on status However if the system hangs due to any reason such as software resource conflict a simple slide of the switch may fail to turn off the power In this case please utilize the forced power off feature by pressing the switch downward and holding for within 10 seconds In case the turmoil is so vigorous that some hardware registers may be confused causing trouble for system restart or even this forced power off please disconnect the UPS battery if installed and the AC power supply for few minutes This may allow all hardware registers to reset This switch can also be programmed as an ON only switch That means if the application program issues a command compliant with the Jiva series technical manual this switch will always turn the system on when activated but will not power off the system when depressed again the forced power off feature will not work in this mode When using this feature please make sure that the software application has the ability to power off the
19. r about 3 years After the battery is nearly exhausted the user must change a new battery otherwise the system RTC and system configuration setup will be lost INSTALLING UPGRADE KIT Please follow the instructions in the manuals delivered with the side mount upgrade kit KP100 SD100 SD200 or BC100 and the rear top mount upgrade kit PD302 to fit them in Jiva 5700G Jiva 5800G construction The USB power arrangement in this system has been particularly designed to help smooth start up of the fingerprint sensor in SD200 WIRELESS PRINTER The whole Jiva series can access the Posiflex wireless thermal printer PP7700 To do this a wireless Dongle DG2000 for this printer must be separately purchased and installed to one of the serial COM ports in Jiva system Please enable the 5 V DC power support for this COM port Notice 2 hooks on rear side of the Dongle and also 2 hooks on either top corner on rear side of main unit of the Jiva system Match the hooks to mount the Dongle to either corner of the Jiva system Should there be more than 2 Dongles to be installed in the application for the advantage of several fixed predetermined connections without need for connection alteration in process the third Dongle and afterwards have to attach to the appropriate positions by use of the self adhesive tape because Jiva series supports only 2 rear top corners with hooks Hooks On Rear Side Of Dongle rI Dongle Hooked On Rear Top a Of Ji
20. r if actually installed there will be a popup message asking the user to agree disabling the UPS function The system will operate under deactivated UPS function no matter agreed or not However the monitoring goes on and the popup message will come back on next system power up boot if not agreed In any case please replace the used up UPS battery at power off if the battery is well connected there but found inoperable by such messages Power Supply The operating voltage range of the power adaptor should cover the local power supply for proper operation The power cable the power outlet and any power fusing arrangements must conform to local safety regulations Please never do any connection disconnection when system is still powered on Please always keep the external power adaptor in a free air circulation POWER ON OFF There must always be at least 10 seconds waiting before switching on again once the system is powered off successfully LED Indicator There is an LED in the logo area or under the printed logo and serves for several purposes The relationship between LED status and other Part 13 conditions is summarized in following table LED Status System Status External Power UPS Battery Powering Up Off Off Off Not present Not possible Off Off Off Present Not allowed Green Off On No influence Allowed Blue On On No influence Not required Blue flash On Off Activated Not required Green ra
21. red for connections to the Jiva TP LT 5700G or Jiva TP LT 5800G except those for special application purposes into the cable passage Insert one end of the cable passage cover under the adjacent cover plate and screw on the two screws Be sure not to damage any of the cables during this operation Now turn the adjustable stand assembly back to normal orientation and arrange all cables to come out of the area for mounting main unit from the bottom edge for ease of later operation PREPARING THE MAIN UNIT On the back of the main unit there are 4 matching pegs and a service window Push open the service window in the direction as indicated in the picture one can find a button cell battery socket two 1 x 2 JP6 9 and two 1 x 3 headers JP11 16 with 1 jumper each and two 2 x 3 header JP13 14 with 2 jumpers each Though it is possible that the contents in the service window may change as time develops Service Window Push Open To The Right 4 Matching Pegs CAUTION Risk Of Explosion If Battery Is Replaced By An Incorrect Type Dispose Of Used Batteries According To The Instructions This battery socket accepts a 3 V button cell Lithium battery CR2032 Part 7 required to support the system real time clock The jumpers in this window are designated for VGA port and COM port power supply function Please consult your dealer for technical support on setup of these jumpers A new Lithium battery can support the system RTC fo
22. rs will be available on our web http www posiflex com tw Now please follow instructions from your system integrator for software recovery Please refer to the System Protection section in chapter USING THE TOUCH POS for guidance on the Time Machine like system recovery OPERATING SYSTEM INSTALLATION This product is a highly professionalized equipment The installation of an OS into a machine without any preloaded OS could constitute major difficulty for average user who either has barely limited technical knowledge of this professionalized equipment or is insufficiently equipped with necessary facilities to accomplish such a task Therefore installation of an OS into a system without preloaded OS is highly discouraged Posiflex shall not be responsible for any technical support to questions arisen due to non preloaded OS Part 11 USING THE TOUCH POS APPLICATION ENVIRONMENT It is very important that you check the following operational guidelines Ventilation This terminal must NOT be operated in an environment with restricted ventilation The installation should be such that there is at least 25mm air clearance around any top or side ventilation holes The installation must also be such that there is a free flow of air around the unit at ALL times Operating Environment The equipment must not be operated or stored in extremes of both temperature and humidity moisture Operating range 5 C to 40 C and up to 80 hu
23. s of the matching holes are at the top as shown in the picture below Align the four matching pegs on the back of the main unit with the four matching holes in the bracket to hold the main unit in the similar manner as installing the main unit onto the stand assembly The stand assembly is not engaged in wall mount operation Wall Mount Bracket Matching Holes LOCATION FOR INSTALLATION As the stand assembly is not involved in wall mount installation the space required for wall mount application will take only the main unit into consideration So the space required is 375 mm in width and 315 mm in height For desk top counter application the adjustable stand assembly requires a base of 270 mm deep and 260 mm wide However please take also the main unit into consideration If the main unit is tilted to near vertical position the total height is 360 mm When the main unit is tilted to near horizontal position the total height required is 275 mm OPERATING SYSTEM RECOVERY For Jiva TP LT 5700G if not using a remote boot operating system the operating system exists in the Compact Flash Card Therefore once the Compact Flash is damaged for any reason the thin client may fail to boot A bootable new Compact Flash Card will be required to have the workstation back to work Please follow instructions given by the System Integrator to deal with situations like that One more advice for CF Card application is that in spite of the fact that it
24. siflex POS system delivered with preloaded OS there is a function built in for system protection A screen as below will pop up for a short period of time in operation system booting up stage Press Chr APIS to Save Rennt sor In normal application nothing has to be done and the system boot up continues However this system protection function is provided for our end users to fight against enormous virus attacks or malicious system invasions nowadays or even some possible system crash Please connect a PS 2 keyboard to KB port of the system to engage this function only when necessary Press the three key combination of Ctrl Alt F12 at the above screen to get a screen display as below C Press F2 to restore anginal software sate Prose FS bo neeme previous aroi amie Presa FA D aye CPA pater sale Presa Cel AE FI to remiaee oreginal Gactory COS Warning This scion mill mmi in bmi of ofl ima mri application Frem ESC to exit Part 16 Please be solemnly alerted that the system restore operation means the irrecoverable erasement of existing data or system setup it is strongly advised to press Esc key to avoid such miserable damage if there is any doubt Pressing F4 key at this screen will save the current status of the whole system and the earlier saved status will be cleared at the same time Therefore please do this save only when you know that your current system s
25. tatus is safe and clear Pressing F3 key at this screen will restore the last saved system status Please be aware that whatever data or any system change ever since last save will be permanently lost by this restore operation Therefore do restore only after you have made all the necessary data preservation Pressing F2 key at this screen will restore your system back to the OS application software situation that your system integrator has put into protection with technical help from Posiflex before they deliver you this POS system with software solution Please note that whatever data or any system change you have made on this system will be lost by this action Pressing F2 key will have no response if your system integrator did not do the protection or if you have erased their effort by action in next paragraph Pressing the three key combination of Ctrl Alt F1 will restore your system right back to the pure OS status Please never take this action unless you know exactly what you are doing and what to do next The whole process may take quite a while TOP MOUNT CUSTOMER DISPLAY Please follow the instructions on the manual that comes along with the top mount customer display PD302 when it is installed SERIAL PORTS COM1 2 3 4 In Jiva TP LT 5700G Jiva TP LT 5800G there are 4 serial ports available except those models using RS232 touch interface Infra Red type tou
26. va System Hooks On Rear Side Of Jiva The n wireless connection supports various application environments from having single Dongle to control single wireless printer to having single Dongle to control multiple wireless printers and further to having multiple Dongles to control multiple wireless printers Unlike usual wireless printer solutions that requires the application software to use the printer server in WLAN the Posiflex wireless connection supports a genuine virtual cable connection thus supports the application software to use even the so called direct I O method for controlling the printer The user may install the relevant driver prior to the application software if the software did not include the Part 8 Posiflex wireless connection driver elements The driver can be found together in delivery of the wireless printer or the Posiflex Product Information CD of version 1 9 or above or please find it on our web http www posiflex com or http www posiflex com tw JOINING MAIN UNIT AND STAND Matching Holes Round Part Slot Part Matching Pegs Removal Hollow M ban T Match the matching pegs on the back of the main unit against the matching holes on the stand First aim the matching pegs toward the upper round part of the hole and make sure that all pegs are inside the holes Then slide the main unit down to move the pegs into the lower slot part of the holes till it clicks Note that all the cables co
27. xt chapter USING THE TOUCH POS UPS Battery ha Removed Batt C attery over a CASH DRAWER The Jiva series is able to control the printer direct drive type Posiflex cash drawers Among them it is recommended that the Posiflex CR 4000 or CR 4210 be used since the terminal has been designed to compliment this cash drawer both mechanically and electrically The Jiva series will directly control the cash drawer using the cash drawer port CR both to operate the opening mechanism and to monitor the drawer open status Both functions may be accomplished under software control of the COM1 serial port through the interface cable supplied with the cash drawer P N 20863018010 Connect the CR cable from CR port to the connector marked signal cable from POS Printer at the rear of the cash drawer The Jiva series offers another advanced feature in the cash drawer control by using the optional split cash drawer control cable CCBLA 238 Part 6 Connect the 6 pole plug of CCBLA 238 to CR port and connect each 8 pole plug to the connector marked signal cable from POS Printer at the rear of one of the cash drawer In this way the Jiva series is capable of controlling two cash drawers independently through software command ROUTING THE CABLES Fix this End of the Cover First ff hp Route Cables under the Cover Connect this End to Main Unit TE This End to Other Devices Place all the cables requi

Download Pdf Manuals

image

Related Search

Related Contents

none TV90CH520S00 Instructions / Assembly  取扱説明書 - スーパー工業  VAVコントローラ Infilex VC 製品仕様書(PDF/1491KB)  Installation Instruction  bombas doble membrana manual de instrucciones lista de  SINGLE-SOCKET EMBEDDED PLATFORM  自治会ハンドブック  Rode MICON 1  お求めいただきました  

Copyright © All rights reserved.
Failed to retrieve file