Home

Pelco TW3004AR Pacemaker User Manual

image

Contents

1. 12 VDC OR 24 VAC POWER SUPPLY omg iQ D 3 ommo 2 MONITOR 1 MONITOR o MONITOR UTP FIXED CAMERA cE JENN 7 oO TW3032P h COCOCOQOQOQOQOQOQOOO0O0O0OQO ee ojo Ho Figure 8 TW3004AR Connected to a 32 Channel Passive Transceiver C1667M 6 06 Figure 9 shows a TW3004AR connected to a TW3004P passive transceiver The TW3004P then connects to a non UTP fixed camera TW3004AR 12 VDC OR 24 VAC POWER SUPPLY MONITOR MONITOR MONITOR MONITOR TW3004P Figure 9 TW3004AR Connected to a 4 Channel Passive Transceiver C1667M 6 06 Specifications ELECTRICAL Input Voltage Power Consumption Wire Type Wire Category DC Loop Resistance Differential Capacitance Transient Immunity Insertion Loss VIDEO CHARACTERISTICS Video Output Format Frequency Response Common Mode Differential Mode Rejection MECHANICAL Connectors BNC 4 Pin Connector 2 Pin Connector 2 5 mm 2 Pin Connector 3 5 mm Construction Finish GENERAL Operating Temperature Relative Humidity Data Transmission LED Indicators Dimensions Unit Weight C1667M 6 06 12 VDC or 24 VAC 50 60 Hz 10 watts Unshielded twisted pair 24 AWG minimum Cat3 or better 52 ohms per 1 000 ft 305 m
2. S4 HORIZONTAL TW3004AR MOUNTING HOLE 2 a a Z a lt LOWER SCREW PHILLIPS gt amp WALL CLIP FLANGE PAN HEAD WITH LOCK WASHER 2 Figure 2 Mounting the TW3004AR Using the Wall Clip C1667M 6 06 SETTING THE DIP SWITCHES The factory default switch positions are shown in Figure 3 Switches 2 5 are set to auto and switch 1 is set to H mode These settings ensure that the adaptive technology in the TW3004AR automatically adjusts the low medium and high frequency components of the video signal allowing for the best possible video transmission OVERRIDE 4K 3K 2K 1K H L L MODE J ol OoAcDY m o m Lz amp r s Figure 3 Default Switch Positions You can override the adaptive technology by setting one of the switches 2 3 4 or 5 to a particular distance 1K 2K 3K or 4K For example if you want to transmit video up to 1 000 feet 305 meters of UTP cable set switch 2 to 1K You can set only one distance at a time The H high and L low modes are available only when switches 2 5 are set to automatic High mode is the default position and is used when the video output into a 75 ohm terminator is greater than or equal to 1 Vp p Low mode should be used when the video output into a 75 ohm terminator is less than 1 Vp p C1667M 6 06 9 APPLICATIONS You can connect the TW3004AR active receiver to
3. transceiver and the TW3001AT active transmitter and CC3610 series Although you can connect these product Cat5 cable Cat5e and Cat 6 are recommended for Always connect the UTP wires on the Cat cable from connect the blue wire to the on the TW3004AR ma to the on the transmitter Table A shows the maximum cable distance with Coaxi TW3004AR to a TW3001P passive transceiver with a particular type of Cat cable Table A Cable Distance with TW3001P Cable Type Maximum Distance Maximum Distance YP with Coaxitron video only Cat3 750 ft 229 meters 1 500 ft 457 meters Cat5 750 ft 229 meters 3 000 ft 914 meters Catbe 750 ft 229 meters 4 000 ft 1 219 meters Cat6 750 ft 229 meters 4 000 ft 1 219 meters Table B shows the minimum size for a single wire and stranded wire Table B Wire Gauge Wire Gauge minimum size Single Wire solid 24 AWG 0 25 mm Stranded Wire flexible 24 AWG 1 0 mm ransmitters such as the TW3001P passive o Pelco UTP cameras such as the CC3710 s using an unshielded twisted pair Cat3 and he best video performance o and from to For example if you sure you connect the other end of the blue wire ron or video only when connecting the C1667M 6 06 Figure 4 shows a TW3004AR connected to a UTP camclosure TW3004AR POWER FRO
4. Installation The following parts are supplied 1 1 1 1 1 Universal power supply Part PS04 1502 0512G Wall clip with screws and washers Power connector 2 pin UTP mating connector Screwdriver MOUNTING The TW3004AR receiver is 3 rack units high and can be mounted into a fiber rack onto a wall using a fiber wall mount kit or into the supplied wall clip USING A RACK You can mount a TW3004AR into either an RK5000PS 3U with power supply or an RK5000 3U without power supply For more mounting information refer to the RK5000PS 3U RK5000 3U Fiber Rack Mount Chassis Installation manual USING WALL MOUNT KITS The optional WM5001 3U wall mount base kit allows attachment of a single TW3004AR to a wall Up to two WM5001 3UEXP wall mount expansion kits can be used to allow attachment of two additional receivers to the wall For more information refer to the Fiber Wall Mount Kits Installation manual C1667M 6 06 USING A WALL CLIP To attach the TW3004AR receiver to a wall using the supplied wall clip refer to Figure 2 and do the following 1 Attach the wall clip to a wall using two screws not supplied 2 Slide the receiver into the clip until the two holes on the bottom of the receiver align with the two holes on the lower flange of the clip 3 Attach the receiver to the clip using the two Phillips pan head screws provided with the clip x a a lt FLANGE Ql veRTICAL MOUNTING HOLE 2
5. 19pF ft max 300 W peak pulse power 8 20 US 72 dB over 0 8 MHz frequency range 4 BNC NTSC PAL SECAM DC to MHz gt 70 dB Video output Rack power UTP input output Power Steel Silver 32 to 167 F 0 to 75 C 0 to 90 noncondensing Supports Coaxitron up to 750 ft 229 m Pelco badge blue status LEDs red green flashing amber 8 75 D x 1 08 W x 4 81 H 22 23 x 2 74 x 12 22 cm 1 56 Ib 0 70 kg C1667M 6 06 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years on FR FT FS Series fiber optic products and TW3000 Series unshielded twisted pair transmission products e Three years on Genex Series products multiplexers server and keyboard e Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty e Three years on PMCL200 300 400 Series LCD monitors e Two years on standard motorized or fixed focal length lenses e Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications e Two years on Esprit
6. INSTALLATION TW3004AR Active Receiver Four Channels for UTP Transmission C1667M 6 06 Important Safety Instructions C1667M 6 06 So oF ee MS Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions o not install near any heat sources such as radiators heat registers stoves or other pparatus including amplifiers that produce heat oa o Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the 0 P bsolete outlet otect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Refer all servicing to qualified serv
7. M RK5000PS 3U MONITOR 12 VDC OR 24 VAC POWER SUPPLY CAMCLOSURE Figure 4 TW3004AR Connected to a UTP Camclosure C1667M 6 06 Figure 5 shows a TW3004AR connected to a UTP fixed camera TW3004AR POWER FROM RK5000PS 3U l OR E Op Li 12 VDC OR 24 VAC Hol POWER SUPPLY FIXED CAMERA 10 PINS MONITOR 5 6 8 PINS 4 5 Figure 5 TW3004AR Connected to a UTP Fixed Camera C1667M 6 06 TW3004AR C1667M 6 06 Figure 6 shows a TW3004AR connected to a UTP Spectra dome for Coaxitron PTZ control A POWER FROM RK5000PS 3U 12 VDC OR 24 VAC POWER SUPPLY MATRIX MONITOR Figure 6 TW3004AR Connected to a Spectra Dome Figure 7 shows a TW3004AR connected to a TW3001P passive transceiver The TW3001P then connects to a non UTP fixed camera TW3004AR POWER FROM RK5000PS 3U aa OR ite be e_O Li 2 VDC OR 24 VAC a pes E o POWER SUPPLY OO 4 CELI 2 1 UTP B O l TW3001P DIRECT FIXED CONNECTION CAMERA i E T MONITOR MONITOR M 1 MONITOR MONITOR Figure 7 TW3004AR Connected to a Single Passive Transceiver C1667M 6 06 Figure 8 shows a TW3004AR connected to a TW3032P passive transceiver TW3004AR POWER FROM RK5000PS 3U 3 OR iene
8. and WW5700 Series window wiper excluding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP displays The lamp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty e Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products e One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months e Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s iability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential
9. d within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco Pelco c o Expeditors 3500 Pelco Way 473 Eccles Avenue Clovis CA 93612 5699 USA South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 REVISION HISTORY Manual Date Comments C1667M 6 06 Original version Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Copyright 2006 Pelco Endura and ExSite are trademarks of Pelco All rights reserved DLP is a registered trademark of Texas Instruments Inc PELCO Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1 09001 United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East
10. damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise he above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are locate
11. ice personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Installation should be done only by qualified personnel and conform to all local codes Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture Use only installation methods and materials capable of supporting four times the maximum specified load A CCC approved power cord must be used to power this equipment when used in China Regulatory Notices This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device pursuant t
12. o Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case he user will be required to correct the interference at his own expense Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada Green The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002 95 EC comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this Mu equipment K This equipment contains electrical or electronic components that must be recycled properly to 4 C1667M 6 06 Description The TW3004AR is a four channel active receiver that can receive live video o
13. ver unshielded twisted pair UTP cable The adaptive technology in the TW3004AR automatically adjusts the low medium and high frequency components of the video signal allowing for the best possible video transmission The adaptive technology eliminates the need for manual adjustment by automatically adjusting to provide the most favorable video transmission depending on cable length needed The unit has been optimized for use with CatSe and Cat6 cable although Cat3 and Cat5 cable can be used for shorter distances The bottom of the TW3004AR has four DIP switches one for each channel Each DIP switch has five small switches four of which can be used to override the adaptive technology by manually selecting the cable distance Switches 2 3 4 and 5 can be set to 1 000 feet 305 meters 2 000 feet 610 meters 3 000 feet 914 meters and 4 000 feet 1 219 meters respectively Switch 1 can be set to high mode and low mode The four LEDs on the front of the unit indicate the status of each channel When an LED lights red there is no UTP video being received A green light means there is UTP video being received A flashing amber light means that there are Coaxitron pan tilt zoom PTZ control commands being transmitted The blue Pelco badge indicates there is power whether you are using the 4 pin rack power connector or the 2 pin power connector The following features are found on the TW3004AR e Full motion color black and white
14. video up to 4 000 feet 1 219 meters with Cat5e or Cat6 e Supports Coaxitron control PTZ control signals up to 750 feet 229 meters e Compatible with all Pelco twisted pair equipped cameras enclosures and domes e Built in surge suppression e Easy termination with removable UTP connector e Supports NTSC PAL and SECAM e Can be mounted into a Pelco fiber rack wall mount base kit or wall clip C1667M 6 06 5 PARTS OF THE RECEIVER O00000 O FRONT BOTTOM Figure 1 TW3004AR Parts Rubber Feet 4 For placing unit on a flat surface such as a desk or shelf Status LEDs 4 Light red when there is no UTP video being received Light green when there is UTP video being received Flash amber when Coaxitron pan tilt zoom PTZ control commands are being received Pelco Badge Lights blue to indicate power when using either the 4 pin rack power connector or the 2 pin power connecto Rack Power Connector 4 r pin power from RK5000PS 3U Power Connector 3 5 mm 2 pin stand alone power 12 VDC or 24 VAC UTP Connector 8 pin connector with removable mating connector BNC Connectors 4 Coax ial output DIP Switches 4 Override the adaptive technology with the manual selection of cable distance 1 000 4 000 feet o 305 1 219 meters Switch 1 on each DIP switch is used for selecting high mode or low mode C1667M 6 06