Home
Patton electronic 4830 Series Network Card User Manual
Contents
1. Respectively from the host ping 172 16 1 99 Note To ping outside your local LAN you will need to configure the default gateway You may now start to configure the SmartNode from scratch using the CLI commands but we recommend that you start your configuration from a template See Downloading a configuration example adapting it to your network and loading it onto the SmartNode on page 6 for further details For a detailed description of the CLI refer to the SmartWare Software Configuration Guide SCG available on the CD ROM and online at www patton com voip Downloading a configuration example adapting it to your network and loading it onto the SmartNode Patton provides a collection of configuration templates on the CD ROM that came with the SmartNode device and also on the support page at www patton com voip appnotes shtml one of which may be simi lar enough to your application that you can use it to speed up configuring the SmartNode Simply download the configuration note that matches your application to your PC Adapt the configuration as described in the configuration note to your network remember to modify the IP address and copy the modified configuration toa TFTP server The SmartNode can now load its configuration from this server Note Patton regularly adds new configuration templates to the collection at www patton com voip appnotes shtml so if you do not see your applica tion on the CD ROM it may have be
2. 1245 600030 SmartNode 4830 Quick Start Guide Authorized European Representative 12 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030
3. damages whatsoever including but not limited to lost profits arising out of or related to this manual or the informa tion contained within it even if Patton Electronics has been advised of known or should have known the possibility of such damages Important Information To use virtual private network VPN and or AES DES 3DES encryption capabilities with the SmartNode 4830 you may need to purchase additional licenses hardware software network connection and or service Contact sales patton com or 1 301 975 1000 for assistance VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 SmartNode 4830 Quick Start Guide Introduction This Quick Start Guide leads you through the basic steps to set up a new SmartNode see figure 1 and to download a configuration Please note that this guide does not replace the detailed Software Configuration Guide and the Getting Started Guide on the CD ROM and available online at www patton com voip SmartNode 4838 VoIP Gateway Router ToIP Integrated Access Device 6 KH MPP Ps e Console Lenet 0 L Enet i L voice Ports Figure 1 SmartNode product SmartNode 4838 shown SmartNodes can be used for a wide variety of IP and voice over IP applications To support and ease the config uration of the SmartNodes configuration templates for the most important applications are available online at http www patton com voip appnotes shtml Setti
4. network mask for the each IP interface eth0 for example Note For the examples in this guide a private network 172 16 1 IP address is used 172 16 40 1 ctx ip router interface eth0 172 16 40 1 if ip eth0 ipaddress 172 16 1 10 255 255 255 0 2002 10 29T00 09 40 LOGINFO Link down on interface eth0 2002 10 29T00 09 40 LOGINFO Link up on interface eth0 172 16 1 10 if ip eth0 3 Make this modified configuration your new start up configuration On the next start up the system will initialize itself using the modified configuration 172 16 1 10 if ip eth0 copy running config startup config 172 16 1 10 if ip eth0 Go to section Connecting the SmartNode to the LAN on page 6 to connect the SmartNode to your network Connecting a PC logging in and configuring the LAN IP address 5 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 SmartNode 4830 Quick Start Guide Connecting the SmartNode to the LAN The 4830 Ethernet ports are auto MDX therefore a straight through wired cable can be used for host and switch connections see figure 3 Network interface Cross over cable Straight through Straight through wired cable wired cable Figure 3 Connecting the SmartNode to the network You can check the connection with the ping command to another host on the local LAN 172 16 1 99 if ip ethO ping lt IP Address of the host gt
5. PE PATTON aE Tle cironics To SmartNode 4830 Series Analog VoIP Integrated Access Device Quick Start Guide SmartNode 4838 VoiP Gateway Router Paz TolP Integrated Access Device a S RS z O FFF ENAS SSL PPT sis x lt v p g e s ee tv eneto Lenti __ voice Ports Approval C Models that are equipped with telecom interfaces have been approved for connection to the public telecommunication network as listed under PSTN regulatory compliance Important This is a Class A device and is intended for use in a light industrial environment It is not intended nor approved for use in an industrial or residential environment VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 Trademark Statement Patton the Patton logo and SmartNode are registered trademarks of Patton Electronics Company The terms SmartWare and SmartView Management Center are trademarks of Patton Electronics Company All other trademarks presented in this document are the property of their respective owners Copyright 2007 Patton Electronics Company All rights reserved The information in this document is subject to change without notice Patton Elec tronics assumes no liability for errors that may appear in this document In no event shall Patton Electronics or its employees and associated companies be lia ble for any incidental special indirect or consequential
6. The system is going down Additional information For detailed information about configuring and operating guidance set up procedures and troubleshooting refer to the SmartNode Series SmartWare Software Configuration Guide and the SmartNode Getting Started Guide on the enclosed Patton VoIP CD ROM or at http www patton com voip On the CD ROM you will also find numerous freeware and shareware tools including TFTP servers Telnet clients etc Additional information 7 www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 SmartNode 4830 Quick Start Guide Compliance EMC compliance e FCC Part 15 Class A e EN55022 Class A e EN55024 Safety compliance e UL60950 1 CSA C22 2 No 60950 1 e IEC 60950 1 e EN60950 1 PSTN regulatory compliance e FCC Part 68 e CS 03 e TBR21 TBR 12 amp 13 El e AS ACIF S016 2001 El AS ACIF S043 2005 DSL Models Radio and TV Interference FCC Part 15 The SmartNode product generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The SmartNode product have been tested and found to comply with the limits for a Class A com puting device in accordance with specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercia
7. en added to the website Connecting the SmartNode to the LAN 6 www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 VolPon SmartNode 4830 Quick Start Guide Note If your application is unique and not covered by any of Patton s configura tion templates you can manually configure the SmartNode instead of load ing a configuration file template In that case refer to the SmartNode Series SmartWare Software Configuration Guide for information on configuring the SmartNode device In this example we assume the TFTP server on the host with the IP address 172 16 1 11 and the configuration named SN cfg in the root directory of the TFTP server 172 16 1 99 if ip ethO copy tftp 172 16 1 11 SN cfg startup config Download 100 172 16 1 99 if ip eth0 After the SmartNode has been rebooted the new startup configuration will be activated When you issue the reload command the SmartNode will ask A if you want to copy the running configuration to the startup con figuration Since you just downloaded a configuration file to the IMPORTANT startup configuration you must answer this question with NO Otherwise the downloaded configuration will be overwritten and lost 172 16 1 99 if ip eth0 reload Running configuration has been changed Do you want to copy the running config to the startup config Press yes to store no to drop changes no Press yes to restart no to cancel yes
8. l installation However there is no guar antee that interference will not occur in a particular installation If the SmartNode product does cause interfer ence to radio or television reception which can be determined by disconnecting the unit the user is encouraged to try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches Compliance 8 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 SmartNode 4830 Quick Start Guide Disconnect all power before servicing CAUTION N The SmartNode product contains no user serviceable parts CAUTION within 1 foot 3 meters of the device and shall be easily accessi The mains outlet that is utilized to power the equipment must be A ble CAUTION FCC Part 68 ACTA Statement FXO ports This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA On the bottom side of this equipment is a label that contains among other information a product identifier in the format US AAAEQ TXXXX If requested this number must be provided to the telephone company The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Par
9. n connect a PC equipped with an RS 232 console port to the Con sole port on the front of the SmartNode Use the included black Ethernet cable and RJ45 to DB 9 adapter for this purpose Model 16F 561 Serial Terminal Note A Patton Model 16F 561 RJ45 to DB 9 adapter is included with each SmartNode 4000 Series device Figure 2 Connecting to the PC 2 Open a Terminal connection to the SmartNode Use the Terminal program included with most PC operat ing systems e g Hyper Terminal on Windows The CD ROM also includes some recommended termi nal programs Connecting a PC logging in and configuring the LAN IP address 4 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 SmartNode 4830 Quick Start Guide 3 Type administrator as the login prompt and press the Enter key after the password prompt do not type anything for the password A prompt will appear consisting of the IP address and gt character login administrator password 172 16 40 1 gt 4 Following log in the SmartNode is in operator execution mode indicated by gt character in the command line prompt With the commands enable and configure you enter the configuration mode 172 16 40 1 gt enable 172 16 40 1 configure 172 16 40 1 cfg Changing the IP address 1 Select the context IP mode to configure an IP interface 172 16 40 1 cfg context ip router 172 16 40 1 ctx ip router 2 Set the IP address and
10. ng up a new SmartNode consists of the following steps 1 Connect a PC to the SmartNode log in and configure your LAN IP address see page 4 for details 2 Connect the SmartNode to the LAN see page 6 3 Download a configuration example adapt it to your network and load it onto the SmartNode see page 6 Introduction 3 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 SmartNode 4830 Quick Start Guide Connecting a PC logging in and configuring the LAN IP address Connecting power and configuring the default IP address Connect the SmartNode to the mains power supply using the included power supply and cable When the RUN LED stops blinking and remains lit the SmartNode is ready The factory default IP settings are listed in table 1 Ifthese addresses do not work with your network they must be changed Contact your network administrator if you are not sure which IP address to use in your installation Table 1 Factory default IP address and network mask configuration Item IP Addresss es Network Mask WAN interface Ethernet O ETH 0 0 DHCP DHCP LAN interface Ethernet 1 ETH 0 1 192 168 1 1 255 255 255 0 DHCP server address range 192 168 1 10 192 168 1 19 255 255 255 0 Note The DHCP server is running on the ETH 0 1 of the SN4830 Series models All Ethernet ports are pre configured and active Connecting to a PC and logging in 1 To access the SmartNode configuratio
11. onformity indicating that Industry Canada technical speci fications were met It does not imply that Industry Canada approved the equipment This Declaration of Conformity means that the equipment meets certain telecommunications network protec tive operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be con FCC Part 68 ACTA Statement FXO ports 9 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 SmartNode 4830 Quick Start Guide nected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone extension cord The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment mal functions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the ground connections of the po
12. t 68 rules and requirements adopted by the ACTA If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service If trouble is experienced with this equipment for repair or warranty information please contact our company If the equipment is causing harm to the telephone network the telephone company may request that you dis connect the equipment until the problem is resolved Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information Industry Canada Notice FXO ports This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is confirmed by the registration number The abbreviation JC before the registration number signifies that regis tration was performed based on a Declaration of C
13. ublic telecommunica tion network EG Konformit tserkl rung see section EMC compliance for English version Produktbezeichnung SmartNode 4830 Die bezeichneten Produkte stimmen in der von uns in Verkehr gebrachten Ausf hrung mit den Vorschriften folgender Richtlinie berein CE Notice 10 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 600030 SmartNode 4830 Quick Start Guide R amp TTE 1999 5 EG Richtlinie des europ ischen Parlaments und des Rates zur Angleichung der Rechtsvorschrifien der Mit gliedstaaten ber Funkanlagen und Telekommunikations Endeinrichtungen und die gegenseitige Anerkennung ihrer Konformit t Konformit t mit der oben erw hnten Richtlinie wird durch das CE Zeichen auf dem Die Sicherheitshinweise in der mitgelieferten Produktdokumentation sind zu beachten Die Ger t best tigt Die unterzeichnete Konformit tserkl rung kann heruntergeladen werden von www patton com certifications Zulassung Der SmartNode ist f r die Anschaltung an das ffentliche Telekommunikationsnetz zugelassen Er darf durch jedermann an eine FXO Schnittstelle angeschlossen und in Betrieb genommen werden Authorized European Representative DRM Green European Compliance Services Limited Oakdene House Oak Road Watchfield Swindon Wilts SN6 8TD UK Authorized European Representative 11 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0
14. wer utility telephone lines and internal metallic water pipe system are connected together This protection may be particularly important in rural areas CE Notice This equipment conforms to the requirements of Council Directive 1999 5 EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual rec ognition of their conformity The safety advice in the documentation accompanying this product shall be obeyed the conformity to the above directive is indicated by the CE sign on the device EC Declaration of Conformity see section EG Konformit tserkl rung for German version Product Description SmartNode 4830 The products described above in the form as delivered are in conformity with the provisions of the following European Directive R amp TTE Directive 1999 5 EC Guidelines of the European Parliament and the Committee for the Harmonisation of the Legal Regula tions of the Member States concerning radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity conformity to the above directive is indicated by the CE sign on the device C The safety advices in the documentation accompanying the products shall be obeyed The The signed Declaration of Conformity can be downloaded from www patton com certifications Approval Models that are equipped with FXO ports have been approved for connection to the p