1. The LINK ACT LED lights when a fiber cable or twisted pair cable connection is good It blinks to indicate activity The collision and full duplex LED report board operating status Boot ROM To add the remote boot feature to a workstation insert the Boot ROM into the ROM socket See Figure on page 2 After power UP the LINK ACT LED should light if not check the following 1 Confirm that the NDM FTX module is properly inserted into the PC workstation master slot or file server master slot 2 Confirm that the PC workstation or the file server is properly connected to a power source and with the power source turned ON 3 Check the fiber cable and twisted pair copper cables for proper connection 4 Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 if those steps fail to produce the desired result Note To connect this device to a router bridge or switch please refer to the corresponding technical manual for the device TRA SITION H Ne networks Declaration of Conformity Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Model NDM FTX xxxxx 01 and NDM FTX xxxxx 0l L Network Interface Cards Part Number NDM FTX ST 01 x NDM FTX SC 01 x NDM FTX MT 01 x NDM FTX SC5 01 x NDM FTX SC20 01 x NDM FTX SB201 01 x NDM FTX SB202 01 x Regulation EMC Directive 89 336 EEC Purpose To declare that the NDM FTX xxxxx 01 and NDM FTX xxxxx 0l L to which
2. fi mode single fiber 20 km 12 4 miles Optional accessories sold separately Part Number Description BTR NDM RPL RPL Bootable ROM Chip BTR NDM PXE PXE Bootable ROM Chip Typical maximum cable distance Installation s ganr reti sensnm 2 Actual distance is dependent upon the Cable Specifications 4 physical characteristics of the network Technical Specifications gt installation Troubleshooting 6 Contact US 0 6 eee I NDM FTX Series Fast Ethernet Dual Media NIC Installation Checklist Before installing the NDM FTX verify that the package contains the following items e NDM FTX Board e LAN Driver CD Please notify your sales representative if any item is missing or damaged Description The NDM FTX module has a bootable ROM socket ROM chip sold separately The two LED indicators LINK ACT and FDX located on the bracket show network board link activities collision and full duplex statuses See Figure 1 Figure 1 LEDs and Boot ROM Socket NDM FTX module installation CAUTION Wear a grounding strap and observe electrostatic discharge precautions when installing the NDM FTX module Failure to observe this caution could result in damage or failure of the NDM FTX module To install the NDM FTX module do the following Important Install the NDM FTX module in a master slot only Locate a master slot on the PC workstation or file server Remove the cover from
3. rate lt 10 9 Single mode fiber recommended 9 um Multimode fiber recommended 62 5 125 um Multimode fiber optional 100 140 85 140 50 125 um NDM FTX ST 01 x NDM FTX SC 01 x NDM FTX MT 01 x 1300 nm multimode Fiber optic transmitter power min 19 0 dBm max 14 0 dBm Fiber optic receiver sensitivity min 31 0 dBm max 17 0 dBm Link budget 12 0 dB NDM FTX SC5 01 x 1310 nm single mode Fiber optic transmitter power min 19 0 dBm max 14 0 dBm Fiber optic receiver sensitivity min 31 0 dBm max 7 5 dBm Link budget 12 0 dB NDM FTX SC20 01 x 1310 nm single mode Fiber optic transmitter power min 15 0 dBm max 8 0 dBm Fiber optic receiver sensitivity min 31 0 dBm max 0 0 dBm Link budget 16 0 dB NDM FTX SB201 01 x 1310 TX 1550 RX nm single mode single stand Fiber optic transmitter power min 14 0 dBm max 8 0 dBm Fiber optic receiver sensitivity min 32 0 dBm max 0 0 dBm Link budget 18 0 dB Fiber cable continued NDM FTX SB202 01 x 1550 TX 1310 RX nm single mode single stand Fiber optic transmitter power min 14 0 dBm max 8 0 dBm Fiber optic receiver sensitivity min 32 0 dBm max 0 0 dBm Link budget 18 0 dB The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC 825 CDRH standard and comply with 21CRF1040 10 and 21CRF1040 11 Technical Specifications For models NDM FTX xxxxx 01 and NDM FTX xxxxx 01 L Standards IEEE 802 3 Expansion bus
4. standard PCI 2 1 2 2 Data rate 10 100Mpbs twisted pair media 100Mbps fiber media LED LINK ACT on the bracket ON communication link flashing activity on link FDX full duplex link ON full duplex link Drivers e NetWare Server 4 1x 5 x e Netware DOS Client ODI e Windows 95 98 2000 2003 XP NT4 0 e Linux Boot server support Novell RPL Boot ROM PXE Boot ROM PCB dimensions 2 5 W x 5 9 D x 0 85 H 63 5 mm W x 149 9 mm D x 21 6 mm H Weight 3 oz 91g approximate Power consumption 1 0A 5VDC MTBF 198 853 hours Bellcore7 V5 0 Operating temp 0 C to 50 C 32 F to 122 F Storage temp 25 C to 85 C 13 F to 185 F Humidity 5 to 90 non condensing Altitude 0 to 10 000 feet Warranty Lifetime WARNING Visible and invisible laser radiation when open DO NOT stare into the beam or view directly with optical instruments Failure to observe this warning could result in damage to your vision or blindness CAUTION Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure The information in this manual is subject to change without further notice 4 Tech Support 1 800 260 1312 International 00 1 952 941 7600 24 hours techsupport transition com Click the Transition Now link for live Web chat 5 NDM FTX Series Fast Ethernet Dual Media NIC Troubleshooting Diagnostics LEDs and Boot ROM LEDS
5. the PC workstation or file server keep all screws 1 2 3 Remove and keep the screws holding the cover over the installation slot 4 Carefully slide the NDM FTX module into the master slot aligning the module with the slot guides Tech Support 1 800 260 1312 International 00 1 952 941 7600 24 hours Install the NDM FTX module continued 5 Ensure that the module is firmly seated in the slot 6 Use the screws from step 3 to secure the module to the workstation or file server housing NDM FTX PCI module configuration For motherboards with automatic PCI configuration e No specific setup is needed e You can enter the system BIOS setup menu to view or specify the interrupt INT line of the PCI slots For motherboards with bus master and interrupt jumpers e Enable bus master operation in a selected PCI slot and select an INT request line IRQ level using the appropriate motherboard jumper e Enable I O on the NDM FTX PCI slot PCI bus system and configuration e Ensure that the PCI machine supports master slots INT multiple sharing and timing compatibility e DO NOT install NDM FTX in PCI slave slots Please refer to your PCI system manual and select the appropriate configuration settings e When installing multiple NDM FTX boards in a server station you should correctly configure the IRQ settings of the PCI slot Up to four NDM FTX modules can be installed in a PCI file server run
6. this declaration refers is in conformity with the following standards CISPR 22 1997 A1 2000 EN 55022 1998 A1 2000 Class A FCC Part 15 Subpart B 21CFR subpart J I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s AS ee Lasher June 302006 Stephen Anderson Vice President of Engineering Date Contact Us Technical support Technical support is available at techsupport transition com US and Canada 1 800 260 1312 24 hours e International 00 1 952 941 7600 24 hours Transition now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web based seminar Transition networks provides seminars via live web based training Log onto www transition com and click the Learning Center link Email Ask a question anytime by sending an email to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Telephone 952 941 7600 Toll free 800 526 9267 Fax 952 941 2322 Tech Support 1 800 260 1312 International 00 1 952 941 7600 24 hours techsupport transition com Click the Transition Now link for live Web chat Compliance Information CISPR22 EN55022 Class A CE Mark CISPR22 EN55022 Class A EN55024 CE Mark FCC regulations This equipment has been tested and found to c
7. TRANSITION networks w NDM FTX xxxxx 01 USER S GUIDE NDM FTX xxxxx 01 standard NDM FTX xxxxx 01 L low profile Fast Ethernet Fiber Dual Media NICs e Fast Ethernet e Copper and Fiber e 10 100Base TX and or 100Base FX Transition Networks NDM FTX series fast Ethernet dual media NIC Network Interface Card provides a 10 100Base TX copper port and a 100Base FX fiber port for installation flexibility in a mixed media environment The dual ports can also provide redundancy for critical applications These NICs come in standard and low profile form factors and include driver support for a variety of operating systems Part Number Port One Copper Port Two Duplex Fiber Optic 10 100Base TX 100Base FX NDM FTX ST 01 RJ 45 ST 1300 nm multimode NDM FTX ST O01 L 100 m 328 ft 2 km 1 2 miles NDM FTX SC 01 RJ 45 SC 1300 nm multimode NDM FTX SC 01 L 100 m 328 ft 2 km 1 2 miles NDM FTX MT 01 RJ 45 MT RJ 1300 nm multimode NDM FTX MT 01I L 100 m 328 ft 2 km 1 2 miles NDM FTX SC5 01 RJ 45 SC 1310 nm single mode NDM FTX SC5 01 L 100 m 328 ft 5 km 3 miles NDM FTX SC20 01 RJ 45 SC 1310 nm single mode NDM FTX SC20 01 L 100 m 328 fi 20 km 12 4 miles NDM FTX SB201 01 RJ 45 SC 1310 TX 1550nm RX single NDM FTX SB201 01 L 100 m 328 fi mode single fiber 20 km 12 4 miles NDM FTX SB202 01 RJ 45 SC 1550 TX 1310 nm RX single NDM FTX SB202 01 L 100 m 328
8. ir Gegenmafinahmen verantwortlich Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilsateur de prende les measures sp cifiques approprices CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes an ein 6ffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verst sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformitat Trademark notice All registered trademarks and trademarks are the property of their respective owners Copyright restrictions 2004 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the US Manual Part Number and Rev 33332 A
9. ning NetWare operating system e NDM FTX server modules share the same INT line with the driver supporting multiple INT services at a time The IRQ of each NDM FTX module should not conflict with other boards e Operation in full or half duplex mode is configured by LAN driver options The operating mode should match the working status of the remote link device e Use EMM386 version 4 49 or higher and install both DOS and EMM386 from the same DOS package to avoid software problems techsupport transition com Click the Transition Now link for a live Web Chat 3 NDM FTX Series Fast Ethernet Dual Media NIC Cable Specifications Copper cable 10BASE T UTP Category 3 4 5 or higher 100Base TX UTP Category 5 or higher Gauge 24 to 22AWG Attenuation 22 0 dB 100m 100 MHz e Straight through MDI twisted pair cable must be used e Shielded STP or unshielded UTP twisted pair cable may be used e Pins 1 and 2 3 and 6 are the two active pairs in an Ethernet network e RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD e Use only dedicated wire pairs for the active pins e g blueAwhite and white blue orange white and white orange etc e DO NOT use flat or silver satin wire Straight Through Cable r R c m g Twisted Pair 1 2 2 A P 3 3 Twisted Pair 2 A The physical characteristics must meet or exceed the IEEE 802 3 specification Fiber cable Bit error
10. omply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European regulations Caution This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem Fall ist der Benutzer fi
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi art. 6120.512 - Migros Samsung 24" Full HD moniteur S24A650D Manuel de l'utilisateur Programa de Física Básica Operating Instructions Type 8791 Positioner SideControl BASIC Piano di sicurezza e di coordinamento - Bandi on-line Optoma DX609 data projector クイックエントリ取扱説明書 Data Ark A-Click Backup User's Guide Etiqueta HA - Solo Uso Informativo - DeFlowplus Copyright © All rights reserved.