Home

Maytag UXT2030AA Ventilation Hood User Manual

image

Contents

1. UXT3030AA SERIES UXT4030AA SERIES UXT3036AA UXT4036AA To register this ECONOMY RANGE HOOD UXT2030AA SERIES product visit UXT2036AA www broancom INSTALLATION INSTRUCTIONS A INTENDED FOR DOMESTIC COOKING ONLY 4 TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS TO REDUCE THE RISK OFINURY TO PERSONS IN THE EVENT OF A RANGE ORSERVE THE FOLLOWING TOP GREASE FIRE OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray turn off contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent 2 warning device such as a tag to the service panel 3 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction 4 codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by
2. and UXT4036AA STAR NDING BRACKET LOCKNUT 7 Replace wiring box cover and screw Make sure that all wiring is safely contained inside 8 Install light 75 Watt maximum For easier installation squeeze plastic lens and remove it from hood Remember to reinstall lens FIG 12 SOCKET 3 Adjust hood so that hood front is flush with cabinet frame 4 Tighten hood mounting screws firmly 5 Fasten wiring to hood with proper electrical connector for type of wiring being used WARNING ALL ELECTRICAL CONNECTIONS MUST BE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 9 Turn on power and check operation of fan and light Make sure that damper operates freely SWITCHES The fan and light are each controlled by a rocker switch The light switch has two positions ON AND OFF The fan switch has three positions HIGH LOW and OFF OFF is the middle position FILTERS UXT3030AA UXT3036AA UXT2030AA and UXT2036AA Hoods Only Remove aluminum filter by turning filter retainer to one side FIG 13 Filter should be washed once a month in a hot detergent solution Aluminum filters are dishwasher safe when installing filter make sure that filter slides under retaining tabs on back of fan housing Turn filter retainer so that arrows on retainer point t
3. c Misuse abuse accidents unreasonable use or acts of God d Incorrect electric current voltage electrical and or gas supply e Improper setting of any control Warranties are void if the original serial numbers have been removed altered or cannot be readily determined 3 Light bulbs water filters and air filters 4 Products purchased for commercial or industrial use ol n O co co The cost of service or service call to a Correct installation errors For products requiring ventilation rigid metal ducting must be used b Instruct the user on the proper use of the product c Transport the appliance to and from the servicer Any food loss due to refrigerator or freezer product failures Expenses for travel and transportation for product service in remote locations Outside of the United States and Canada this warranty does not apply Contact your dealer to determine if another warranty applies Consequential or incidental damages sustained by any person as a result of any breach of these warranties Some states do not allow the exclusion or limitation of consequential or incidental damages so the above exclusion may not apply If You Need Service First see the Troubleshooting section in your Use and Care Guide or call the dealer from whom your appliance was purchased or call Maytag Services LLC Customer Assistance at 1 800 688 9900 USA and 1 800 688 2002 Canada to locate an authoriz
4. 01057 47001057 Light Lens 47001080 47001080 47001080 Screw Nut Kit Includes 2 10 16 x 500 screws and 2 10 16 sheet metal nuts 47001059 47001074 47001059 Fan Blade 03050041 03050041 03050041 6 32 Locking Nuts 2 Required 47001060 47001060 47001060 Motor Mounting Bracket 47001088 47001075 47001088 Motor Assembly Includes Key Nos 6 7 amp 8 47001062 47001076 47001062 Filter 47001063 47001063 47001063 Filter Retainer 706189 8B x 1 4 Hex Head Sheet Metal Screws 2 Required 47001078 Damper Flap 47001079 Damper Bushing 47001064 Damper Assembly Includes Key Nos 13 amp 14 47001065 47001065 47001065 Nameplate Black 47001083 47001083 47001083 Nameplate White 47001066 47001066 47001066 2 Speed Motor Switch Black 47001081 47001081 47001081 2 Speed Motor Switch White 47001067 47001067 47001067 Light Switch Black 47001082 47001082 47001082 Light Switch White 47001068 47001068 47001068 Motor Receptacle with Wires 71001171 71001171 71001171 10 32 x 1 2 Green Ground Screw Light Bulb 75 Watt not included Standard hardware May be purchased locally Not shown 4 Warranty Limited One Year Warranty Parts and Labor For one 1 Year from the original retail purchase date any part that fails in normal home use will be repaired or replaced free of charge Canadian Residents The above warranties only cover an appliance installed in Canada that has been certified or
5. TRICAL WIRING 3 Use 1 1 4 bit to drill opening for electric wiring 4 Cut out duct opening in wall or cabinet with saber saw or keyhole saw 5 Center hood in installation opening and trace keyhole slots onto wood filler strips on cabinet bottom 6 Screw four 10 x 7 8 wood screws into exact center of narrow end of traced keyhole slots Allow 3 8 of screws to project so that hood can be fitted into place later This section for UXT2030AA UXT2036AA UXT3030AA and UXT3036AA hoods ony UXT4030AA and UXT4036AA hoods skip this section and go on to Install Range Hood NOTE These instructions will follow plans made on Page 2 Start at the exterior and run ductwork back to the range hood For best possible performance use the shortest possible duct run and a minimum number of elbows Do not vent a range hood into an attice space A buildup of grease in the attic could become a fire hazard Use only metal ductwork DO NOT USE PLASTIC DUCT Assemble duct run securely so that in case of a grease fire on the range the fire will be contained inside metal ductwork Tape all duct connections 2 Follow appropriate directions below for type of duct run you install a Wall Cap Discharge FIG 7 Use saber saw or keyhole saw to to cut hole slightly larger than duct size used so that duct will line up easily with damper duct connector on hood Install casing strips if cap will be installed on siding Attach requi
6. UXT3036AA ONLY Install damper duct connector over opening made in STEP 4 Use 8B sheet metal screws provided FIG 3 UXT2030AA and UXT2036AA hoods ONLY Install Model 87 damper purchase separately over opening in top of hood ELECTRICAL KNOCKOUTS 4 UXT3030AA and UXT3036AA hoods ONLY Remove duct knockout Insert screwdriver under edge of knockout break tabs and peel knockout back with pliers FIG 3 PREPARE THE INSTALLATION LOCATION Omit STEP 1 if hood will be installed under cabinets with flush bottom 1 For installation on recessed bottom cabinets only Attach a wood filler strip at each side of recessed are under cabinet Use two 1 x 2 strips cut to length If recess is deeper than 1 use thicker strips Attach strips with 1 1 4 wood screws 3 from end end of strip See FIG 4 2 Measure and mark the following FIGS 5A amp 5B a Electrical wiring opening in wall or cabinet b Duct opening in wall or cabinet UXT2030AA UXT2036AA UXT3030AA and UXT3036AA ONLY wk 13 15 16 For 30 RANGE HOOD 16 15 16 For 36 RANGE HOOD i UXT3030AA epee cat i1 UXT3036AA UXT4030AA l UXT4036AA l I F 7 ym CENTER LINE HOOD WIDTH 39 3 UXT2030AA UXT2036AA PREPARE THE INSTALLATION LOCATION CONT WARNING WHEN CUTTING OR DRILLING INTO WALL OR CABINET BE CAREFUL NOT TO CUT EXISTING ELEC
7. ed servicer e Be sure to retain proof of purchase to verify warranty status Refer to WAR RANTY for further information on owner s responsibilities for warranty service If the dealer or service company cannot resolve the problem write to Maytag Services LLC Attn CAIR Center P O Box 2370 Cleveland TN 37320 2370 or call 1 800 688 9900 U S A and 1 800 688 2002 Canada U S customers using TTY for deaf hearing impaired or speech impaired call 1 800 688 2080 User s guides service manuals and parts information are available from Maytag Services LLC Customer Assistance Notes When contacting about a service problem please include a Your name address and telephone number Model number and serial number Name and address of your dealer or servicer Aclear description of the problem you are having Proof of purchase sales receipt b c d e 99043046C
8. er HOMEOWNER Use and Care Information on Page 6 This section for UXT2030AA UXT2036AA UXT3030AA and UXT3036AA hoods only UXT4030AA and UXT4036AA hoods skip this section and go on to Prepare the Hood Begin planning ductwork by deciding where duct will run between the range hood and the outside For best performance use the shortest possible duct run and a minimum numaber of elbows There are several choices shown FIGS A F below FIG A Ducting directly through the wall for range hoods mounted on an exterior wall Shown are two ways to duct through an outside wall If a wall cap is used directly off the back of the hood special care must be taken to make sure that the damper in the damper duct connector on the hood damper in the wall cap do not interfere with each other when the hood is operating This could result in either inadequate air delivery or backdrafts If this condition does exist remove the hood damper flap Sometimes when using a wall cap it is easier to duct vertically and then use an elbow as shown FIG B FIG A WALL CAP PLANNING DUCTWORK INSTALLATION In more complex ducting situations a 3 1 4 x 10 rectangular ducting range hood UXT3030AA and UXT3036AA hoods can be converted to a round duct by means of a transition N ROOF CAP 7 ROUND DUCT DAMPER WALL CAP FIG C Straight up through the roof us ing 7 round duct for single story instal 3 1 4 x 10 la
9. list ed by appropriate test agencies for a compliance to a National Standard of Canada unless the appliance was brought into Canada due to trans fer of residence from the United States to Canada The specific warranties expressed above are the ONLY warranties provided by the manufacturer These warranties give you specific legal rights and you may also have other rights which vary from state to state CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW MAYTAG CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY STATE TO STATE OR PROVINCE TO PROVINCE Warranty amp Service What is Not Covered By These Warranties 1 N Conditions and damages resulting from any of the following a Improper installation delivery or maintenance b Any repair modification alteration or adjustment not authorized by the manufacturer or an authorized servicer
10. oward front and back of hood FILTER RETAINER FILTER UXT4030AA and UXT4036AA Hoods Only The UXT4030AA and UXT4036AA hoods are equipped with a ductfree filter Remove filter by turning filter retainer to one side FIG 13 The ductfree filter is not washable and will last up to twelve months with normal use Replace the filter when colored side becomes noticeably dirty or discolored When installing filter make sure that filter slides under retaining tabs on back of fan housing MAKE SURE THAT COLORED SIDE OF FILTER IS NEXT TO FAN WHEN FILTER IS INSTALLED Turn filter retainer so that arrows on retainer point toward front and back of hood USE AND CARE WARNING ALWAYS DISCONNECT ELECTRIC POWER BEFORE SERVICING RANGE HOOD FAN ASSEMBLY Remove filter Remove two screws holding motor bracket to range hood and unplug fan assembly Be careful not to allow fan assembly to drop when screws are removed FIG 15 CLEANING Clean your hood with a mild detergent suitable for painted surfaces DO NOT USE ABRASIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS Fan assembly may be vacuumed Fan assembly is lifetime lubricated and never needs oiling HOW TO AVOID A COMMON RANGE TOP GREASE FIRE e Your range hood provides a protective barrier between the cooking surface and the cabinets e Keep fan filters and grease laden surfaces CLEAN according to instructions e Always turn hood ON when cooking at high heat to kee
11. p the cooking area and the hood cooler e Use high heat settings only when necessary e Never leave cooking surface unattended Boil over causes smoking and greasy spillovers that may ignite e Always use adequate sized utensils e If preparing flaming foods such as Cherries Jubliee always turn hood ON to HIGH to prevent a high heat situation which can cause damage or fire HOW TO EXTINGUISH A COMMON RANGE TOP GREASE FIRE e Never pick up a flaming pan If dropped flames can spread quickly e DO NOT USE WATER A violent stream explosion may result Wet dishcloths or towels are also dangerous e Smother flames with a close fitting lid cookie sheet or metal tray e Flaming grease can also be a extinguished with baking soda or multi purpose dry chemical extinguisher e Turn off surface units if you can do so without getting burned SERVICE PARTS Service parts for your range hood are shown with part numbers List the hood model number on spec label located on inside of hood and the part numbers of all parts being ordered FIG 16 3 x 10 Ducted Hood Only Ductfree Hood Only UXT3030AA UXT4030AA UXT2030AA UXT3036AA UXT4036AA UXT2036AA Series Series Series 3 1 4 X 10 Ductfree 7 Round Ducted Hood Hood Ducted Hood 47001055 47001055 47001055 Outlet Box Cover 706189 706189 706189 8 18 x 3 8 Phillips Truss Sheet Metal Screws 47001056 47001056 47001056 Bulb Holder with Wires 47001057 470
12. red amount of duct to wall cap and run duct back to hood Fasten cap to wall and caulk well SOFFIT INSTALL THE DUCTWORK b Roof Cap Discharge FIG 8 Cut a hole in roof slightly larger than duct size being used Run ductwork down to hood location Leave 3 4 of duct projecting above roof surface on high side Trim duct parallel to roof pitch and seal all around duct with roof cement Carefully trim shingles and slide back of roof sheet under shingles Nail roof sheet to roof under shingles at top two comers and two sides Nail sheet directly to roof in four places at bottom Using roof cement seal all nail heads and shingles which were cut or lifted Do not seal bottom edge of roof sheet ROOF CAP CABINET INSTALLING RANGE HOOD WARNING 6 Strip 1 2 of insulation foam wires Connect white to white black TURN OFF THE PROPER CIRCUIT AT THE SERVICE to black and green to prepared hole with green ground screw ENTRANCE BEFORE WIRING THIS RANGE HOOD provided FIG 11 1 Run electric wiring through hole drilled in wall or cabinet Split wiring for 6 and install proper connector for type of wire used FIG 9 BLACK WIRES 2 Position hood so that a Wiring is routed through knockout opening FIG 10 b Large part of keyhole slots fit over hood mounting screws FIG 10 aS j Wd WHITE wires c Damper duct connector slides into ductwork 2 _ j UXT3030AA UXT3036AA UXT4030AA
13. the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels a violent stream explosion will result Use an extinguisher ONLY if A You know you a Class ABC extinguisher and you already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NFPA 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Do not use this range hood with an additional speed control device A 8 To reduce the risk of fire use only metal ductwork CAUTION 9 Use with approved cord connection kit only 1 For general ventilating use only Do not use to exhaust hazardous or explosive 10 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE 1 Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings 2 2 Always t
14. tions UXT2030AA and UTX2036AA DUCT only FIG B ROOF CAP ADJUSTABLE ELBOW ROOF CAP Tea 3 1 4 x 10 Li DUCT X WALL CAP L a S 6 ROUNI 6 ROUND DUCT DUCT 3 1 4 x 10 TO 6 ROUND DUCT gt Aaron 7 ie FIG D Ducting straight up through the roof using 3 x 10 rectangular duct For single story installations UXT3030AA and UXT3036AA hoods only FIG E Ducting between the ceiling joists FIG F Straight up through the roof for multi story installations or through the using 6 round duct for single story soffit space above the cabinets where the installations soffit connects to an outside wall 1 Unpack hood and check contents You should receive 1 Aluminum Filter UXT3030AA UXT3036AA UXT2030AA and UXT2036AA hoods only 1 3 x 10 Damper Duct Connector mounted inside of hood for shipping only UXT3030AA and UXT3036AA hoods only 1 Ductfree Filter UXT4030AA and UXT4036AA hoods only 2 Remove wiring box cover Under cover find 1 Plastic Bag containing loose mounting hardware PREPARE THE HOOD KEYHOLE SLOTS a zes DUCTFREE FILTER UXT4030AA amp amp UXT4036AA HOODS WIRING BOX ALUMINUM FILTER UXT3030AA UXT3036AA UXT2030AA UXT2036AA DAMPER DUCT CONNECTOR UXT3030AA amp UXT3036AA HOODS ONLY PREPARE THE HOOD CONT 3 Remove top or rear electrical knockout FIG 2 5 UXT3030AA AND
15. urn hood ON when cooking at high heat or when cooking flaming foods 2 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan 4 or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element Drill electric or ratchet drive 1 8 drill bit for drilling pilot holes Pliers Oooooodo materials and vapors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit For best capture of cooking impurities your range hood should be mounted 18 24 above the cooking surface Please read specification label on product for further information and requirements 1 1 4 wood bit for drilling electrical wiring access hole One straight blade and one phillips head screwdriver Pencil and ruler and or tape measure Saber saw or keyhole saw for cutting 1 x 2 wood strips to length and cutting wall or cabinet openings Oo transition if necessary and roof Caulking metal snips duct tape duct with elbows and or wall cap as required Q Electrical wiring and supplies of type to comply with local codes The following materials are required recessed bottom kitchen cabinets only for installations on Q Two 1 x 2 x 12 approximate length wood strips pur chase locally Q Four 1 1 4 long flat head wood screws purchase locally INSTALLER Leave This Manual With Homeown

Download Pdf Manuals

image

Related Search

Related Contents

"user manual"  Manual de uso e instalação do sistema de aquecimento  Transformer Manual 300W Update_20052014  

Copyright © All rights reserved.
Failed to retrieve file