Home

Maximatic SBID 6052i Headphones User Manual

image

Contents

1. with Windows 7 for these procedures There is a persistent image on An image displayed for too long the display This is not permanent Turn off the interactive display and the computer and leave them off for the same amount of time as the persistent image was on screen Turn on the interactive display and the computer Additional Resources On Screen Display OSD Reset The OSD main menu items allow you to reset the picture adjust audio schedule PIP OSD multi display and display protection individually However if you want to reset them all at once you can use the FACTORY RESET feature With the FACTORY RESET feature you can reset the OSD options back to factory settings except for the date amp time language OSD rotation input name change security password security lock and security password To access the FACTORY RESET Press the Menu button on the remote control The main menu icons appear on the screen Select the PRO ADVANCED option Select the FACTORY RESET option Select YES to finish the factory reset A w NNa Applicable Knowledge Base articles Knowledge Base Correcting Registry or System Preferences File Issues Knowledge Base Designating the Correct Display for Multiple Displays with Windows 7 Knowledge Base Gesture Recognition Doesn t Work When Using the Floating Toolbar Knowledge Base Using the SMART Board Interactive Display Frame Diagnostic Utility e Knowledge Base Two Line
2. pencil nib might be worn out The camera view may be obstructed The interactive display may have experienced an electrostatic discharge or a power interruption Your computer s video resolution settings don t match your display s native resolution The computer may be experiencing connection or display card issues Replace the pencil nib Check to see if there is anything on the interactive display that is blocking the view of the camera s Reset the interactive display by pressing the Reset button on the touch connection panel SC11 or disconnecting and reconnecting the power cord This restarts all components of the interactive display All data including the orientation data stored in the touch connection panel is retained Refer to the section titled Connecting a Personal Computer in the NEC MultiSync s521 User s Manual for the correct computer video resolution and then change the computer s screen resolution right click the desktop and then select Properties gt Settings gt Screen Resolutions to match the interactive display Check the display VGA cable and make sure it is properly connected to the computer OR Use a different computer This helps you to identify if your display card is compatible with your interactive display OR Use the On Screen Display OSD Picture and Adjust controls to focus and adjust the image by increasing or decreasing the fine adjustment If you change the d
3. Board SBID 6052i Interactive Display Installation and User s Manual for solutions if there are issues with the touch connection panel SC11 Note The touch connection panel SC11 is located behind the top centre section of the interactive display If your interactive display is mounted on a wall you might require a ladder and mirror to see the LED status and diagnostic lights 2 Troubleshoot touch connection panel SC11 recognition camera pencil eraser or calibration issues by running the SMART Connection Wizard If the computer doesn t recognize the touch connection panel SC 11 or if there are potential issues with the camera s pencil eraser or calibration always run the SMART Connection Wizard first to see if it can identify and resolve any related issues To run the SMART Connection Wizard s troubleshooting procedures refer to p 39 41 of the SWART Board SBID 6052i Interactive Display Installation and User s Manual 3 Position your finger or pencil at a right 90 angle to the interactive display For best results keep your finger or pen at a right 90 angle to the interactive display Do not allow your wrist clothing or other fingers to get too close to the display This may trigger an inaccurate touch point When you draw with your index finger keep your other fingers curled up as if you were holding a coin in the palm of your hand When you draw with a pen hold your pen so that you fingers are away from the pen
4. SMART Board SBID 6052i Interactive Display Troubleshooting Guide Introduction This document helps you to identify and resolve different issues that customers might have with the SMART Board SBID 6052i interactive display Initial Troubleshooting Customers call in for a variety of product issues If you can t easily identify the cause of the issue it is recommended that you first instruct the customers to check the LED status and diagnostic lights to see if there are any issues with the touch connection panel SC11 If the LED status and diagnostic lights indicate that the touch connection panel SC 11 is functioning instruct the customers to run the SMART Connection Wizard to see if there are any touch connection panel SC 11 recognition camera s pencil eraser or calibration issues In addition you can remind the customers to ensure their finger or pencil is at a right 90 angle to the interactive display The following section outlines how to troubleshoot the interactive display using the LED status and diagnostic lights and the SMART Connection Wizard and a tip on how to position your finger or pencil on the interactive display 1 Troubleshoot touch connection panel SC11 issues using the LED status and diagnostic lights There are two LED status and diagnostic lights located on the touch connection panel SC11 These two lights indicate the condition of the touch connection panel SC 11 Refer to p 38 39 of the SMART
5. isplay mode the OSD Adjust settings may need to be reconfigured May 2010 SMART Board SBID 6052i Interactive Display Troubleshooting Guide Symptoms There is a delay between your touch writing and the response of the interactive display Digital ink doesn t align with your pencil or finger when writing on the interactive display There is no sound when using your interactive display The SMART Board icon doesn t appear in the notification area SMART Technologies Your computer might be running too many applications Your computer doesn t meet the minimum system requirements You might not be using a USB 2 0 cable to connect the interactive display to the computer Excessive light in the room is effecting the interactive display s performance The interactive display hasn t been properly oriented Speakers haven t been installed speakers aren t included with the interactive display There are audio connection issues There are volume mute issues There are computer audio issues SMART Board software isn t running Solution Close some open applications Upgrade your computer or replace it with a more powerful computer A computer with USB 2 0 support is recommended For connection information refer to the section titled Making Power and Computer Connect on p 12 of the SMART Board SBID 6052i Interactive Display Installation and User s Manual Close any blinds and shades
6. nib SMART Technologies May 2010 SMART Board SBID 6052i Interactive Display Troubleshooting Guide Troubleshooting Symptoms The following table lays out the solutions for some specific symptoms Symptoms There is no image on your display or a No Input message appears Your interactive display does not respond to touch but you can see the computer desktop You might see a red light on the touch connection panel SC11 The pencil doesn t work SMART Technologies Your computer is in Standby mode The display input is incorrect Your computer is off Your computer isn t connected to the interactive display The touch connection panel computer and interactive display aren t receiving power The main power switch is turned off Your computer doesn t recognize the touch connection panel SC 11 OR The cameras are not transmitting information to the computer The pencil s battery charge might be low or the battery is dead The battery orientation might be backwards Solution Touch the display move the mouse or touch any key on your keyboard to activate your computer If you re using a laptop turn on the external video connection or change the display input Turn on your computer or press the computer s reset button and log on as usual Ensure the USB 2 0 cable is connected from your computer to the touch connection panel SC11 Ensure The touch connection panel p
7. or turn off all halogen and LED lights in the room area Orient your interactive display Install speakers and connect them to either the computer or the LCD display side terminal panel Refer to the section titled Connecting External Equipment with the Terminal Panels on p 18 of the SMART Board SBID 6052i Interactive Display Installation and User s Guide Ensure the audio cable is properly connected Check to see if the volume is muted OR Check the volume level Check to see if the computer supports an audio signal through the DisplayPort If unsure contact the computer manufacturer Double click the SMART Board Tools icon on your desktop or select Start gt SMART Board Tools May 2010 SMART Board SBID 6052i Interactive Display Troubleshooting Guide Symptoms You are not able to designate If you have multiple interactive displays Solution Complete the calibration and the correct display for multiple connected to a single computer displays with running the Microsoft Windows 7 Microsoft Windows 7 The operating system Windows may not calibration or orientation of assign touch recognition to the the interactive display correct display proceeds as expected but a touch on one display registers on another orientation processes on each display and then Configure your pen and touch displays Refer to the Knowledge Base document titled Designating the Correct Display for Multiple Displays
8. ower cord is securely connected to the touch connection panel The computer power cord is securely connected to the computer The display power cord is securely connected to the terminal panel You may also try a different power cord to confirm the problem is not related to the cable Turn on the main power switch Tip The main power switch is located on the terminal panel underneath the interactive display Unplug and plug in the power cord to reset the interactive display Ensure the USB 2 0 cable is connected from the touch connection panel SC11 to the computer Replace the battery Remove the battery Insert it correctly inside the battery compartment May 2010 SMART Board SBID 6052i Interactive Display Troubleshooting Guide Symptoms Gaps appear in the digital ink when writing on the display Writing touch recognition doesn t work in a particular area of the display The interactive display behaves erratically the cursor jumps around or the display becomes unresponsive The image is blurry too large or doesn t completely fill the interactive display The image is unstable unfocused or swimming SMART Technologies The SMART Board service may not be running The SMART Board Diagnostics dialog box may be open Solution Start the SMART Board service Close the SMART Board Diagnostics dialog box The SMART Board Control Panel may be Close the SMART Board Control Panel open The
9. s Appear on the 400 Series SMART Board Interactive Display Frame Touching and Drawing on Your SMART Board Interactive Whiteboard is Inaccurate 2010 SMART Technologies ULC All rights reserved SMART Board SMART Notebook smarttech and the SMART logo are trademarks or registered trademarks of SMART Technologies ULC in the U S and or other countries All other third party product and company names may be trademarks of their respective owners Printed in Canada 05 2010 SMART Technologies May 2010