Home
LXE Tx800 Personal Computer User Manual
Contents
1. TEC 60950 1 2001 1 Edition EN 61000 6 2 2001 Incl Group and national differences for the CENELEC countries and national differences for US and Canada according to CB Bulletin 109A USCA 05 I 50 E EQ TX8000GWW D ARC User Manual Tx800 Appendix A Lithium Battery Safety Statement A Caution Lithium battery inside Danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by battery manufacturer US Attention Contient une pile de lithium Risque d explosion dans le cas o la pile ne serait pas correctement remplac e Remplacer uniquement avec une pile semblable ou equivalente au type de pile recommand par le fabricant FR Forsigtig Indeholder lithiumbattterier Risiko for eksplosion hvis batteriet udskiftes forkert Ma kun udskiftes med samme eller tilsvarende type som anbefalet af fabikanten DK Varoitus tuote k ytt laservaloa Skannerissa jokin seuraavista tarroista Lue Huomio kohta FI Vorsicht Enth lt Lithium Batterie Bei unsachgemaBem Ersatz besteht Explosionsgefahr Nur durch gleichen oder vom Hersteller empfohlenen Typ ersetzen DE Attenzione Batteria al litio Pericolo di esplosione qualora la batteria venga sostituita in maniera scorretta Sostituire solo con lo stesso tipo o equivalente consigliato per il fabbricante IT Atenc o Cont m pilha de l tio H perigo de explos o no c
2. 1 1 Who should read this manual Use this manual if you are responsible for installing setting in operation maintaining or repairing Trux Solutions It provides information you need for mechanical and electrical installation of Akerstr ms Trux AB Tx800 and configuration of basic functions You should e familiar with mechanical electrical and computer installations e Have experience using computers and knowledge of the operating system that will run on the Tx800 The manual does not describe how to install and use the operating system or applications 1 2 Notices This manual describes the product s basic design and main procedures for installing operating and maintaining the product There might be deviations between information in this manual and the appearance and functions in the delivered product because of differences in hardware and software versions When product updates that affect function and security are available at www lxe com or from LXE s support department E EQ TX8000GWW D ARC 7 About this manual 1 3 How to use this manual To Prepare for electrical installation Prepare for product installation Install Akerstr ms Tx800 Operate Tx800 Maintain proper operation Solve problems 1 3 1 Prerequisites User Manual Tx800 Read Chapter Safety Product description Product installation Using the product Maintenance Troubleshooting NYDN D To perform some tasks listed above you ll
3. For more details on the Bluetooth option please refer to the Trux Configuration Guide available on the documentation CD 4 4 7 External monitor If needed an external monitor can be connected to Tx800 s VGA connector 4 4 8 Other external accessories Mobile communication such as GPS GSM GPRS WCDMA systems can be connected to the COM ports Serially connected peripherals sometimes require power supply from the computer 1 Connect the barcode reader to the correct COM port see Figure 9 position 4 or 5 2 Activate the power supply on the COM port 5V from COMI or 12V from COMO using Trux Computer Manager Please refer to the Trux Configuration Guide available on the documentation CD for details on using the Trux Computer Manager For information about how to configure accessories like GPS and GSM GPRS WCDMA products see the manufacturers documentation 26 E EQ TX8000GWW D ARC User Manual Tx800 Installation 4 4 9 Audio Out Audio Out is a standard earphone outlet 3 5 mm 4 4 10 Mic In Mic In is a standard microphone inlet 3 5 mm 4 4 11 Antenna Tx800 comes with two mounted antennas used for WLAN GPRS communication If externally mounted antenna is needed cabling and connectors for this is available from Akerstr ms Trux AB If a Bluetooth antenna is needed this is connected to port 12 section 4 4 1 Wireless communication equipment not supplied by Akerstr ms Trux AB has to comply with loca
4. E ce RR era 29 Re te 20 5 12 Tuming oft Ihe eadein on in Pub er nn pde UD Scie IP Dp an needs qu MP as 29 5 2 e H 29 5 2 1 Hatug the stylus to select screen obIebts 30 2 2 2 EE 30 323 AT nn naine 30 2 2 4 LED InOICUOBE initiale 31 6 MAINTENANCE 33 6 1 Cl aning Hie cin 33 6 2 Checking CONNECTIONS n 33 OE Rl oo E eher 33 7 TROUBLESHOOTING 35 ss WC 35 TI The pampuler Will QOL eM cn de 35 ANON EI VI EE 35 7 2 Problems with peripherals T 36 pou ben MOSS Ait ei 36 Tac EE EE eebe 36 T23 36 APPENDIX 37 l Technical SEC mms 37 4 E EQ TX8000GWW D ARC User Manual Tx800 Table of Contents D Port SANG AXA K A A nA 39 Technical Recommendations suus nina Ri dk Rd KR R KR bkn 46 47 DOME 9 Y Y 48 ON WEE 49 VII Warranty Support and Service nissan 52 VIII Environmental Care Information iiisnnrnnne 53 GE 54 X Francais Avertissement emarque nnn 55 Illustrations Figure 1 Overview connections dnd InterfabeS v oec m etate edat testen recte ane 12 Figure 2 Overview connections and interfaces under the service
5. 4 or 5 or e USB ports see Fig 7 pos 9 For more information refer to the printer s documentation The printer will need to be supplied with power separately E EQ TX8000GW W D ARC 25 Installation User Manual Tx800 4 4 5 Serial Barcode readers Use this installation procedure for all serial bar code readers that Akerstroms Trux AB supplies for Tx800 Select the appropriate port COM2 supplies 12V COMI 5V or connect it using a keyboard wedge connector 1 Connect the barcode reader to the selected port 2 Activate the power supply on the COM port in Trux Computer Manager Please refer to the Trux Configuration Guide available on the documentation CD for details on using the Trux Computer Manager To convert the signals from the scanner to keystrokes you can use the FreeFloat WLinq software WLinq listens for signals at the COM port and converts these to the corresponding key that is sent to the active application WLing comes with all bar code readers from Akerstr ms Trux More details about WLinq is found in Appendix IV 4 4 6 Bluetooth bar code readers Use this installation procedure for Bluetooth bar code readers supported by the Tx800 Poweron the Bluetooth scanner 2 Use the Bluetooth Device Wizard in the Microsoft Windows Control Panel to discover and manager the Bluetooth scanner connection 3 Do not use the ComponentSoft wedge software provided with the LXE 8650 Bluetooth Ring Scanners on the Tx800
6. C Not connected 5 GND Ground 6 RGND Red Ground 7 GGND Green Ground 8 BGND Blue Ground 9 N C Not connected 10 GND Ground 11 N C Not connected 12 SDA DDC_Data 13 CRT_HS CRT Horisontal Sync 14 CRT_VS CRT Vertical Sync 15 SCL DDC_Clock E EQ TX8000GW W D ARC Appendix 45 Appendix User Manual Tx800 lll Technical Recommendations Recovery The recovery media can be ordered as a stand alone product 46 E EQ TX8000GWW D ARC User Manual Tx800 Appendix IV Disclaimer All Akerstr ms Trux AB s software products whether imbedded in ROMs or other hardware or delivered on CD ROM or other media including all related manuals and documentation collectively Akerstr ms Software are proprietary to Akerstr ms Akerstrims reserves all right title and interest in and to the Akerstr ms Software not explicitly licensed herein including without limitation all copyrights patents and other proprietary rights kerstr ms Software contained in or embedded with purchased hardware products may only be used with the related hardware products No embedded Akerstr ms Software may be separated from any hardware products as shipped by Akerstr ms Akerstr ms Software delivered separately from a hardware product may only be used on a single CPU at a time Stand alone Akerstr ms Software may not be copied except for 1 back up copy in machine readable form provided such copy are used for back up only and provided all copyright
7. Typical usage areas for Tx800 include Mounted in forklifts operating in warehouses connected to a logistic system via a wireless network In trucks using global positioning system GPS navigation routes maps and picking lists In forestry machines using GPS navigation maps and felling instructions E EQ TX8000GW W D ARC 11 Product description 3 3 Connections and adapters 12 User Manual Tx800 3 3 1 Interfaces and connections Figure 1 Overview connections and interfaces Connections and interfaces port lid Position Function Power supply 12V DC 50W Mic in Audio out COM2 RS232 12V COMI RS232 5V VGA external monitor Multipurpose connector USB 2 0 RS232 12 V 1 AD MN I RJ 45 Ethernet 10 100 LAN 2x USB 2 0 pi PS 2 Mouse PS 2 Keyboard N Bluetooth antenna connector E EQ TX8000GWW D ARC User Manual Tx800 Product description 3 3 2 Under the service lid Figure 2 Overview connections and interfaces under the service lid Position Function 1 USB 2 0 2 Harddrive 3 Compact Flash slot behind HD cable 4 Battery UPS 5 Mini PCI slot 6 PC Card slot option 3 4 Tx800 series Akerstr ms Tx800 is developed for companies that want flexibility and need powerful computers that enable several heavy applications to run simultaneously The Tx
8. documentation CD for details on using the Trux Computer Manager 30 E EQ TX8000GWW D ARC User Manual Tx800 Using the Tx800 5 2 4 LED indications 1 On Off 2 UPS mode 3 Harddrive Light sensor LED Figure 15 LED Indicators The On Off button s built in LED indicates operational mode 1 On Off LED Operational Mode Indication Off and not powered Off dark Off but powered Green flash very slow Operating normally Green on Suspend Green flashing slow Green flashing fast Over voltage shutdown Red on Over temperature Red flashing 2 UPS Mode Function Indication UPS battery powered Green flashing fast UPS battery charging Green on or flashing slow UPS battery charged Off dark 3 Harddrive LED Function Indication Harddrive activity Green flashing No activity Off dark E EQ TX8000GW W D ARC 31 Using the Tx800 User Manual Tx800 32 E EQ TX8000GWW D ARC 6 Maintenance 6 1 Cleaning the screen Clean the screen when necessary Use a soft slightly damp cloth If required use a cleaning solution that is intended for computer screens screen Never use detergents or any other liquid not intended for this use when cleaning the 6 2 Checking connections Check regularly that all connections are firmly in place and that all cables are securely fastened check that strain relief is working properly 6 3 Service To secure operation of the unit various
9. e Check strain relief cabling contacts and connections e Restart the computer and if possible try using another keyboard mouse 7 2 2 Touchscreen accuracy If the touch screen accuracy is off target e Calibrate the touch screen stylus using the touchscreen application 7 2 3 Communication If communication problems arise with a wireless network GPS or GSM GPRS products test coverage in two ways e Check the computer s software for indications of poor coverage often indicated by an icon in the systray e Put another computer in the same location to see if the same problem occurs 36 E EQ TX8000GWW D ARC Appendix Technical Specifications Processor RAM Storage Screen Graphics Card Ports Connectors Antenna Cooling Power Supply Intel Pentium M 1 4GHz 1024 MB DDR Intel Pentium M 1 4GHz 512 MB DDR Intel Celeron M 1 0GHz 1024 MB DDR Intel Celeron M 1 0GHz 512 MB DDR Intel Celeron M 600MHz 1024 MB DDR Intel Celeron M 600MHz 512 MB DDR 40 GB IDE ATA 2 5 automotive harddrive 4 GB Compact Flash 2 GB Compact Flash 10 4 TFT Flat Panel SVGA 800X600 Max 400 cd m Contrast 500 1 Automatic ambient light sensor Intel Extreme Graphics 2 2x PS 2 Keyboard mouse 2 Serial port COM1 COM2 2x USB 2 0 port 1 Multi Purpose connector USB 2 0 RS232 1 RJ 45 Ethernet 10 100 1 Audio Out Head set 1 Audio in microphone Internal front speakers WLAN 802 11 a b g h Internal connect
10. information contained on the originals is included in the copy Except as expressly permitted by mandatory applicable law and this Agreement Customer agrees not to copy modify de compile reverse engineer disassemble or otherwise discover the kerstr ms Software in whole or part Customer shall not remove or obscure any copyright notices or proprietary legends contained within the kerstr ms Software The KERSTR MS SOFTWARE IS PROVIDED AS IS All Non Akerstr ms Software products are provided under the terms and conditions of the software license agreement if any from such software provider applicable to such Non Akerstr ms software If no license agreement is provided Non Akerstr ms software is provided with the same terms and conditions as applies to the Akerstr ms Software License costs update responsibility functionality interoperability of the customer image are under the responsibility of the customer Akerstr ms is not responsible to any consequence costs due to faulty illegal or accidentally related issues to the customer image creation E EQ TX8000GW W D ARC 47 Appendix User Manual Tx800 V Tx800 Software 48 The following software is installed on a new Tx800 Freefloat WLinq WLinq is an integration tool for auto id solutions Featuring communication and control to devices connected to COM ports physical or virtual USB and Bluetooth For use it with barcode readers scales RFID readers and other s
11. need e Akerstr ms Trux AB or other manufacturers documentation related to options and peripherals e Manufacturers product documentation for the e Operating system and other applications e Global positioning system GPS e Global system for mobile communication GSM e General packet radio service GPRS 1 3 2 Symbols used This manual contains these symbols abbreviations and terms Symbol Heading Description Warns about risk of damage to people or property Always follow the instructions provided in conjunction with this symbol Calls your attention to problems that may arise if a measure is not taken or is taken incorrectly E EQ TX8000GWW D ARC 2 Safety 2 1 2 1 Personal safety Keep this in mind A Always exercise caution when working with electricity 2 2 Product safety 2 2 1 Supplying power Tx800 have to be supplied with an external fuse before connecting to recommended voltage see 4 2 1 Connect only the recommended voltage Any other voltage may damage the product or make its operation fail The external electrical system should be designed to prevent voltage peaks A DC DC transformer is predominantly used to electrically isolate the Tx800 from the vehicle chassis see 4 2 1 2 2 2 Humidity moisture cold and heat Make sure the operating environment is within the standards described in Appendix I Technical specs A Don t turn the Tx800 on unless environmental conditions
12. tension avant d entrer dans une unit de stockage froide Avant l installation veillez ce que tous les crit res relatifs l environnement soient respect s Vous trouverez une liste de ces crit res en Annexe I dans les Sp cifications Ne changez pas les vis d origine avec lesquelles sont mont s les supports Des vis trop longues peuvent endommager le syst me lectrique de l ordinateur Soyez toujours prudent lorsque vous travaillez avec l lectricit Si la masse du v hicule n est pas la m me que celle du ch ssis du v hicule vous devez alors monter l ordinateur sur des patins en caoutchouc Ne connectez jamais l alimentation aux prises 5 ou 6 qui servent la fonction de noir de l cran d crite la section 2 2 Vous pouvez d finir cette fonction dans l application Trux Computer Manager cf 4 3 1 Seuls les salari s IT exp riment s sont autoris s utiliser le logiciel Trux Computer Manager car des param tres incorrects peuvent avoir des effets ind sirables sur certaines fonctions Si vous modifiez ou r installez le syst me d exploitation de l ordinateur vous pouvez tre amen r installer les pilotes pr install s SG Ge e eeb Pe E EQ TX8000GW W D ARC 35 Appendix User Manual Tx800 Une fois que les p riph riques sont connect s fixez les c bles sur la partie inf rieure de l ordinateur qui comporte des trous pr vus pour les brides de
13. 800 comes in various configurations to meet your requirements You can select the Windows XP Professional or XP Embedded operating systems processors and primary memory based on the types and numbers of applications that you run at the same time Akerstr ms Tx800 can be used as a robust thin client running various client server applications With Windows XP Embedded you get total control of the user environment and users only have access to applications on a need to use basis E EQ TX8000GW W D ARC 13 Product description 3 4 1 Peripherals and accessories User Manual Tx800 Listed below are some of the peripherals which can be connected to the Tx800 The Section column lists the sections in this manual describing how to install the peripheral For information on use refer to the documentation that accompanies the product More peripherals can be found at www lxe com Peripheral Section Keyboard 4 4 3 Mouse 4 4 3 Printer 4 4 4 Barcode reader 4 4 5 External monitor 4 4 6 GPS system 4 4 7 Mobile communication 4 4 7 Headset Audio out 4 4 8 Microphone 4 4 9 Antennas 4 4 10 14 E EQ TX8000GWW D ARC 4 Installation Before mounting the Tx800 write down the license key for the operating system It s located on the chassis under the port lid 4 1 Mounting the unit Tx800 should be mounted in a way that enables the operator to easily perform tasks while in the vehicle When position
14. User Manual Tx800 Triton User Manual Tx800 Notice LXE Inc reserves the right to make improvements or changes in the products described in this manual at any time without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy LXE assumes no liability resulting from any errors or omissions in this document or from the use of the information contained herein Further LXE Incorporated reserves the right to revise this publication and to make changes to it from time to time without any obligation to notify any person or organization of such revision or changes Copyright Notice This manual is copyrighted All rights are reserved This document may not in whole or in part be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form without prior consent in writing from LXE Inc Copyright 2009 by LXE Inc An EMS Technologies Company 125 Technology Parkway Norcross GA 30092 U S A 770 447 4224 Trademarks LXE and Spire are registered trademarks of LXE Inc RFTerm is a registered trademark of EMS Technologies Norcross GA Microsoft Windows and the Windows logo are registered trademarks of Microsoft Corporation in the United States and or other countries and RAM Mount are both trademarks of National Products Inc 1205 S Orr Street Seattle WA 98108 Intel and Pentium are trademarks or registered tr
15. able to length and strip the wire ends If the blackout screen box is not used do not strip the green and yellow wires Route the power cable the shortest way possible The cable is rated for a maximum temperature of 105 C 221 F When routing this cable it should be protected from physical damage and from surfaces that might exceed this temperature Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate Note If the vehicle is equipped with a panel containing Silicon Controller Rectifiers SCR s avoid routing the power cable in close proximity to these devices Always route the cable so that it does not interfere with safe operation and maintenance of the vehicle 5 Remove the lid from the DC to DC converter Attach the stripped wire ends to the DC to DC converter A DC Input B DC Output C Looms to secure wiring E EQ TX8000GWW D ARC 19 Installation 20 10 User Manual Tx800 The input and output blocks each have two and two minus connectors Either connector in the block can be used to connect the matching polarity wire Use the looms and wire ties to secure all wiring then reattach the cover with the screws If the blackout screen box is used attach the stripped wire ends to the box Refer to section 4 2 3 and the label on the blackout screen box for proper wiring connection BLACKOUT SCREEN 104007 000 12724 Connect the DC to DC converte
16. ademarks of Intel Corporation or its subsidiaries in the United States and other countries WLinq is a trademark of FreeFloat AB The Bluetooth word mark and logos are owned by the Bluetooth SIG Inc and any use of such marks by LXE Inc is under license All other brand or product names are trademarks or registered trademarks of their respective companies or organizations When this manual is in PDF format Acrobat Reader Copyright 2009 Adobe Systems Incorporated All rights reserved Adobe the Adobe logo Acrobat and the Acrobat logo are registered trademarks of Adobe Systems Incorporated applies Revision Notice Revision Section Explanation B Rear Cover Revised contact information B 4 4 5 Bar Code Readers Split into two sections serial and Bluetooth C Notices and Copyrights Revised for 2009 Revision Initial Release October 2008 Revision B January 2009 Revision C March 2009 2 E EQ TX8000GWW B Table of Contents 1 ABOUT THIS MANUAL 1 1 Who should read this 1 2 Noleas NEGER KEKNEEREEKEEREEKKERKEEOERENEKSEEAERKKEERERKEKSEEEEEKKEEREREKEEKEEEERKEEE 1 3 How to use this 1 cn MEN 2 SAFETY safety ciao 2 2 Product Safely sm ssscunncinennmanssssmacenbenaseesescianensensac
17. all 8 mm holes 70 3 1 hole 08 mm Figure 5 Location of holes for 2 25 ball 4 Before drilling Check behind next to the presumed location for pre installed electrical cabling etc Verify placement with owner manufacturer Now drill holes for the attachment screws 5 Firmly fasten the bracket onto the mounting surface using bolts Before mounting Tx800 onto the bracket it s easier to have all the wiring done the openable cable protection tube and the port lid in place E EQ TX8000GW W D ARC 17 Installation User Manual Tx800 4 2 Electrical installation Always exercise caution when working with electricity 4 2 1 Connecting to power source The Tx800 comes with a four meter four wired power cable brown for positive and white for negative and 2 conductors yellow and green to enable the screen black out function if selected If the black out screen function is not used see section 4 2 2 If the black out function is used see section 4 2 3 Connect the brown part of this cable to positive and the white part to negative on the DC DC converter power source and fuse it according to these specifications shown below Specification external power source Always observe input voltage range specified on the DC to DC power supply and the optional screen blackout box Voltage 12 VDC 10 Always use insulated DC DC transformers in vehicles Power 50 W Fuse 5 A slow blow fuse 3 A for o
18. are met 2 2 3 Interference Ensure that e nearby electrical cabling mains supply is run so that interference does not occur e immediate environment meets requirements stated in the specified standards see Appendix IV regarding interference 2 2 4 Vibrations Tx800 should be mounted in a way that vibrations transmitted to it does not exceed the limits it is designed for see Appendix I Specifications E EQ TX8000GWW D ARC 9 Safety User Manual Tx800 10 E EQ TX8000GWW D ARC 3 Product description 3 1 Design and functionality kerstr ms Trux AB designed and developed Tx800 for mounting on mobile or stationary units Rugged design intense screen brightness and exceptional reliability make Tx800 suitable for demanding environments in which vehicles such as forklifts forestry machines and trucks operate Tx800 is designed to withstand vibrations moist and dust Tx800 is based on a standard PC platform that enables use of most types of software available for Windows XP Professional or Windows XP Embedded Tx800 can be used as a standalone computer or as a thin client which requires an application server The model is equipped with Pentium M or Celeron M processor built in hard disk and battery backup function The battery UPS function ensures that data isn t lost during momentary loss of power Tx800 is available with several options and peripherals mentioned in this manual 3 2 Typical usage
19. aso de uma substitui o incorreta Substitua somente pelo mesmo tipo ou equivalente recomendado pelo fabricante PT Varning Inneh ller litiumbatteri Fara f r explosion om batteriet r felaktigt placerat eller av fel typ Anv nd endast samma eller motsvarande typ batterier rekommenderade av tillverkaren SE Advarsel Innmontert Lithium batteri Eksplosjonsfare ved feil montering av batteri Benytt kun batteri anbefalt av produsent NO Cuidado Pila de litio adentro Peligro de explosi n si la pila se reemplaza incorrectamente Reemplace solamente con el mismo tipo o equivalente recomendado por el fabricante ES Oppassen Bevat Lithium batterij Incorrrecte plaatsing van batterij kan leiden tot explosiegevaar Alleen vervangen door hetzelfde of door fabrikant aanbevolen gelijkwaardig type NL E EQ TX8000GW W D ARC 51 Appendix User Manual Tx800 Vil Warranty Support and Service 52 Warranty The Tx800 has a warranty of one year from the date of delivery The warranty assumes that the product was used in a way that can be considered normal and that all the requirements in this manual are met If alterations are made to the computer without the consent of kerstr ms Trux AB the warranty will no longer apply Support To secure operation of the unit various types of support agreements are available for Tx800 Contact kerstr ms Trux AB for more information If any problem occur always start b
20. c bles N oubliez pas que les syst mes d exploitation n ont pas tous une prise en charge int gr e de la souris par exemple DOS oo 56 E EQ TX8000GWW D ARC User Manual Tx800 Appendix E EQ TX8000GW W D ARC 57 LXE Contact your local LXE representative or LXE Headquarters United States LXE International Headquarters 800 664 4593 Sales 32 15 29 28 20 770 447 4224 General Rf4u lxe com info lxe com Repair and customer service LXE International Service Center 770 449 0154 31 346 21 70 60 877 493 0947 support lxe com lxehelp lxe com
21. ction 3 3 User Manual Tx800 6789 Pin Signal Type Purpose 1 DCD RS232 Input Handshake 2 RXD RS232 Input COM I Receive data 3 TXD RS232 Output COMI Send data 4 DTR RS232 Output 1 Handshake 5 GND Ground Ground 6 DSR RS232 Input Handshake 7 RTS RS232 Output 1 Handshake 8 CTS RS232 Input Handshake 9 EXTPWR Power out Power supply 5 VDC 40 Supplies 5 VDC for peripherals activated in Trux Computer Manager E EQ TX8000GWW D ARC User Manual Tx800 COM2 Serial COM1 9 Pin D sub M position 4 section 3 3 6789 Pin Signal Type Purpose 1 DCD RS232 Input COM2 Handshake 2 RXD RS232 Input CON2 Receive data 3 TXD RS232 Output COM2 Send data 4 DTR RS232 Output COM2 Handshake 5 GND Ground Ground 6 DSR RS232 Input COM Handshake 7 RTS RS232 Output COM2 Handshake 8 CTS RS232 Input COM2 Handshake 9 EXTPWR Power out Power supply 12 VDC E EQ TX8000GW W D ARC Supplies 12 VDC for peripherals activated in Trux Computer Manager Appendix 41 Appendix 42 USB USB 2 0 x2 position 9 section 3 3 User Manual Tx800 1234 Pin Signal Type Purpose 1 VCC USB power 5V Power out 2 USBO Input Output USB data 3 USBO Input Output USB data 4 GND Ground Ground E EQ TX8000GWW D ARC User Manual Tx800 Multi
22. erial devices WLinq is bundled with the Tx800 It will run in demo mode if installed from scratch or normal mode based on the original installation licensing regulations Stand alone licences for WLinq can be ordered from Akerstr ms Trux AB e wlingeng exe English version e wlinqswe exe Swedish version Tx800 Computer Manager Handles settings for sound light power from ports UPS start up and shutdown etc Install the application with all options checked Freefloat Access One Terminal Emulator Terminal emulating software for accessing mainframes AS 400 s Unix hosts etc Trux Speedometer Handles Speedstep technology supported by some CPUs Make sure the Trux 800 power scheme has been installed and selected This is done via Control Panel gt Performance and Maintenance gt Power Options gt Power Schemes Touchscreen software Drivers to support the touchscreen and software for calibrating the pointing accuracy Select COM3 in the installation wizard Communication devices Install the proper software for your communication device e g WLAN card Tx800 device drivers All the device drivers are preinstalled E EQ TX8000GWW D ARC User Manual Tx800 Appendix VI Certification FCC Information This device complies with FCC Rules part 15 Operation is subject to the following conditions 1 This device may not cause harmful interference and 2 This device must accept any interference that may be recei
23. esttenagennn 24 4 EE DONNER ne dt 2 2 2 Humidity moisture cold and heat ee ette aba vite Viri ead 2 SAME eRe OO m 2 25 ViIbtatlols 3 PRODUCT DESCRIPTION 3 1 Design and functionality 4 co E o Pm 3 3 Connections and adapters nan 3 3 1 Interfaces and connections ss eee eere ener ee enr 3 3 2 Under the serviced au eoe eases te ED Det Ra OE E Ete E 34 TBO SEVES TT Y E A Y v 341 1 Peripherals and BOCES OIE egene 4 INSTALLATION 41 Mounting HIE rts MORE Drac ad s rad 4 2 Electrical installation me 4 2 1 Connecting TO pOWer BOUNCE eee 4 2 2 DC to DC KEE 4 2 3 Blackout screen function X 4 4 Installing peripherals sssaannnsanennenesss E EQ TX8000GWW D ARC Table of Contents User Manual Tx800 44 1 Ports E 24 44 2 Supplying power EE 25 44 3 Keyboard and MOUSE enee 25 AE Noir ann E ae 25 Barcode ROIS nn HB DM TURN M Re 26 4 4 6 code readers 26 S External E 26 26 AIO OU aan en 21 OS E 27 4A LT ATOM m gt 21 QAI 0E dt named 28 5 USING THE Tx800 29
24. ing the computer in the vehicle carefully account for the operators working situation An ergonomically correct installation with an optimal field of vision greatly facilitates the operators work Before installation ensure that all the environmental requirements are met Check Appendix I Specifications Also check with the owner manufacturer before drilling holes in the vehicle E EQ TX8000GW W D ARC 15 Installation User Manual Tx800 4 1 1 Mounting brackets You can order several different types of brackets for the Tx800 The brackets have built in shock absorption and can move in all directions A AN ZS dis m LR 5 ih Figure 3 Brackets are available in 2 dimensions in 3 lengths see below Bracket with 1 5 ball Bracket with 2 25 ball 95 mm 3 75 128 mm 5 007 154 mm 6 00 213 mm 9 407 233 mm 9 14 328 mm 13 00 16 E EQ TX8000GWW D ARC User Manual Tx800 Installation 1 Check that the planned location of the computer meets ergonometric and field of vision requirement 2 Ensure there is sufficient space underneath and above the Tx800 easier to perform service connect and disconnect cables There should be enough space behind the unit making the passive cooling work correctly 3 Mark the positions of the holes on the mounting surface See Figures 4 and 5 below 5 5 mm holes cc 98 Figure 4 Locations of holes for 1 5 b
25. is to shut down using the operating system This provides better protection against loss of data 5 2 Touchscreen The Tx800 is equipped with a pressure sensitive touchscreen Rather than using a mouse as pointing device users select objects by touching the screen with a stylus or a finger Always use the accompanying stylus to point drag or tap the screen Never use metallic or sharp pointed objects E EQ TX8000GWW D ARC 29 Using the Tx800 User Manual Tx800 5 2 1 Using the stylus to select screen objects To select an object on the interface gently tap the screen e One time to click e Two times in rapid succession to double click e the mouse symbol in the system tray down in the right corner the next click will then be a right click 5 2 2 Calibrating the touchscreen Touch screen accuracy is calibrated using the touch screen application 5 2 3 Adjusting brightness Figure 14 Screen Brightness Screen brightness is adjusted using the buttons or on the front s right side The screen s background lighting can be turned off by holding both buttons simultaneously Background lighting is restored by pushing one of the buttons or by touching the screen The ambient light autosensor is located on the front to the left of the brightness controls In Trux Computer Manager there are settings for adjusting the behavior of the ambient light control Please refer to the Trux Configuration Guide available on the
26. l Radio and Telecom Terminal Equipment directives E EQ TX8000GW W D ARC 27 User Manual Tx800 Installation 4 5 Mounting the port lid Cut the provided openable cable protection tube to the appropriate length Put the cables in one half of it and then put the other half on according to fig 9 Figure 11 Applying the openable cable protection tube Before mounting the port lid fit the cable tube in the sockets of the chassis and lid Figure 12 Mounting the port lid The screws used for the port lid should be alternately tightened to provide proper dust and moist protection IP65 requirement Fasten the cable tube in the vehicle without putting strain on the tube Now the Tx800 is ready to be mounted in the vehicle 28 E EQ TX8000GWW D ARC 5 Using the Tx800 5 1 Operating 5 1 1 Starting the computer Figure 13 On Off button To turn on the computer e Press the on off button on the computer s front left side see Fig 11 or Depending on the settings in Trux Computer Manager Tx800 also can be started by touching the integrated touch screen or when turning the external power source on Please refer to the Trux Configuration Guide available on the documentation CD for details on using the Trux Computer Manager 5 1 2 Turning off the computer To turn off the computer e Shut down using the operating system s interface or e Press the On Off button on the computer s left side The first hand choice
27. les exigences du R glement sur le mat riel brouilleur du Canada Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de Classe A prescrites dans le R glement sur le brouillage radio lectrique dits par le minist re des Communications du Canada RF Safety Notice Caution This device is intended to transmit RF energy For protection against RF exposure to humans and in A accordance with FCC rules and Industry Canada rules this transmitter should be installed such that a minimum separation distance of at least 20 cm 7 8 in is maintained between the antenna and the general population This device is not to be co located with other transmitters Important This symbol is placed on the product to remind users to dispose of Waste Electrical and Electronic Equipment WEEE appropriately per Directive 2002 96 EC In most areas this product can be recycled reclaimed and re used when properly discarded Do not discard labeled units with trash For information about proper disposal contact LXE through your local sales representative or visit www lxe com E EQ TX8000GW W D ARC 49 Appendix User Manual Tx800 The product complies with the harmonized European standards and technical specifications listed below EN 61000 6 4 2001 EN 61000 6 2 2005 FCC part 15 Subpart B Additionally all models are CB certified and comply with the standard below
28. lid eisen eege oreet tees 15 Figure 3 Brackets are avauable in 2 damensions in 3 lengths see below ottenere 16 Figure IL ceataons otbdholes E 17 Location ob Moles dor 2 25 Dalle Hte dioses i tetto iet 17 EE el om eeu a ter no poo DERE ER be bete dio tient 18 Figure 7 Warns Diasram Without Blackout Screen BOX ro 21 Figure Winne Diagram With Blackout Screen BOX in poo Detroit 22 LE 24 Figure 10 Strain relieving brackets for USB and PS 2 connectors 25 tie openabl cable protection tube rei eo ree acp t ena Fest cur eee 28 Figure 12 Mounts the port EERSTEN 28 Figure 15 EE 29 Figure l4 Screen BASES EE 30 Eure 15 EED Ind E 31 E EQ TX8000GWW D ARC 5 Table of Contents User Manual Tx800 6 E EQ TX8000GWW D ARC 1 About this manual This manual covers the following topics related to installation start up operation and maintenance of Tx800 e Safety considerations e General product information e Product installation procedures e Product use and maintenance e Troubleshooting The appendices provide this reference information technical specifications port signals environmental considerations fulfillment of EU and US compliance regulations warranty support service and Akerstr ms Trux AB addresses and phone numbers
29. nsor e Defroster Please refer to the Trux Configuration Guide available on the documentation CD for details on using the Trux Computer Manager Only experienced IT personnel should use the Trux Computer Manager because incorrect settings could produce undesired results in Tx800 s behavior E EQ TX8000GW W D ARC 23 Installation User Manual Tx800 4 4 Installing peripherals Akerstr ms Trux AB offers peripherals to enhance the use of Tx800 Peripherals ordered with the computer comes with pre installed drivers If you order them later or from a supplier other than Akerstr ms Trux AB you might have to install drivers if so refer to the peripheral s documentation 4 4 1 Ports for connecting peripherals Port lid Figure9 Ports Connections and interfaces port lid Position Function 1 Power supply 12V DC 50W 2 Mic in 3 Audio out 5232 option 12V from pin 9 5 COMI RS232 option 5V from pin 9 6 VGA external monitor 7 Multipurpose connector USB 2 0 RS232 5 12 V 8 RJ 45 Ethernet 10 100 LAN 9 2x USB 2 0 10 PS 2 Mouse 11 PS 2 Keyboard 12 Bluetooth antenna connector The following section describes function and use of the ports Strain relief Use the strain relief to prevent the contacts from disconnecting from the unit while operating The brackets for strain relief can be turned around to fit various contact lengths Use st
30. ors 1x USB 2 0 1x Mini PCI Dual band 2 4 5GHz Passive cooling 12 VDC 10 50 Integrated Li Po Lithium Polymer battery Integrated battery charger Option DC DC converter Continued on the following page E EQ TX8000GW W D ARC 37 Appendix Power Consumption Operating System Dimensions Weight Options Temperature Limits Vibration tested Shock tested Moisture tested Degree of protection Standard 38 2 5 A typ 4 A max 0 7 A typ 1 0 A max Windows XP Professional Windows XP Embedded 279 x 229 x 77 mm 11 0 x 9 0 x 3 0 inches 2 9 kg 7 7 Ib Flash disk 1 PC card type II Bluetooth Defroster GPRS EDGE WCDMA Hardened touchscreen external antenna 30 50 C Storage 20 50 C Operating According to IEC 60068 2 64 Test Fh Vibration According to IEC 60068 2 29 Test Eb Bump According to IEC 60068 2 30 Test Db IEC 60529 IP65 Rated Conforms with CE FCC and ETL standards User Manual Tx800 E EQ TX8000GWW D ARC User Manual Tx800 Port Signals PS 2 PS2Connectors Keyboard and mouse position 10 and 11 section 3 3 PS 2 Keyboard PS 2 Mouse Pin Signal Pin Signal 1 KBDData 1 MSData 2 Reserved 2 Reserved 3 Ground 3 Ground 4 Volt 4 Volt 5 KBDClock 5 MSClock 6 Reserved 6 Reserved E EQ TX8000GW W D ARC Appendix 39 Appendix COM Serial COM1 9 Pin D sub M position 5 se
31. out Blackout Screen Box E EQ TX8000GW W D ARC 21 Installation User Manual Tx800 4 2 3 Blackout screen function This function is disabled by default but can be activated in Trux Computer Manager In the power supply connector there are two pins 5 and 6 dedicated to dimming the screen for example when the vehicle is set in motion when the pedal is pressed When the vehicle stops when the pedal is released the screen is lit again Connect pins 5 green wire and 6 yellow wire to the vehicle s pedal relay by means of an insulated electrically open close relay contact Blackout Screen Box is an option from Akerstr ms Trux AB which handles this If the screen s black out function isn t used insulate the end of the green and yellow wires on the open end of the cable EXISTING CIRCUITRY ON VEHICLE Blackout Screen Box TRUX COMPUTER FORKLIFT BATTERY MOTION CIRCUITRY e g Parking MAIN SWITCH Break Switch 5A slow fuse Close to power source Circular Power Connector BROWN Supplied Power Cable Shielding to be trimmed ISOLATED DC DC Figure 8 Wiring Diagram With Blackout Screen Box 22 E EQ TX8000GWW D ARC User Manual Tx800 Installation 4 3 Settings The Trux Computer Manager application is used to configure many options such as e Configuring the UPS function e Settings for Startup and Shutdown e Power for peripherals e Blackout screen function e Sound e Ambient light se
32. ptional screen blackout box Fuses ARE NOT supplied by Akerstr ms Then connect the power cable to the computer s power supply outlet see Fig 6 Never connect power to pins 5 or 6 They are used for the black out screen function described in section 4 2 3 Figure 6 Power supply connector 18 E EQ TX8000GWW D ARC User Manual Tx800 Installation For proper and safe installation the input power cable must be connected to a fused circuit on the vehicle This fused circuit requires a user supplied 5 Amp maximum time delay slow blow high interrupting rating fuse If the supply connection is made directly to the battery the fuse should be installed in the positive lead within 5 inches of the battery positive terminal v For installation by trained service personnel only Risk of ignition or explosion Explosive gas mixture may be vented from battery Work only in well ventilated area Avoid creating arcs and sparks at battery terminals How To Connect Vehicle Electrical Connection 1 Please review section 4 2 2 without blackout screen box or section 4 2 3 with blackout screen box before beginning power cable install 2 The Tx700 must be powered off 3 Begin by connecting the power cable to the Tx700 Work from the Tx700 with the last connection being to the vehicle s power source 4 Route the cable from the Tx700 to the DC to DC converter and optionally the blackout screen box Cutthe c
33. purpose Multi Purpose 15 Pin D sub M position 7 section 3 3 12345 Multi purpose 11 12 13 14 15 Pin Signal Type Purpose 1 5 5 V Power 5 V USB Power Supply 2 RXD RS232 Input COM 4 Receive data 3 TXD RS232 Output COM 4 Transmitting data 4 Reserved Not used 5 12V Power out COM I Power supply 5 VDC 6 USB Input Output USB data 7 USB Input Output USB data 8 GND Ground Ground 9 Reserved Not used 10 GND Ground Ground 11 GND Ground Ground 12 RTS RS232 Output COM4 Handshake 13 CTS RS232 Input COMA Handshake 14 Reserved Not used 15 Reserved Not used 3 Supplies 12 VDC for peripherals activated in Trux Computer Manager E EQ TX8000GW W D ARC Appendix 43 Appendix User Manual Tx800 Ethernet RJ 45 Ethernet 10 100 8 Pin Modular position 8 section 3 3 Hm 8 7 6 5 4 3 2 1 Pin Signal Function 1 TX Transmit data pair 2 2 TX Transmit data pair 2 3 RX Receive data pair 3 4 Not used pair 1 5 Not used pair 1 6 RX Receive data pair 3 7 Not used pair 4 8 Not used pair 4 44 E EQ TX8000GWW D ARC User Manual Tx800 VGA VGA connector 15 Pin D sub F position 6 section 3 3 15 14 13 12 11 Pin Signal Function 1 CRT_R CRT Red 2 CRT_G CRT Green 3 CRT_B CRT Blue 4 N
34. r to the vehicle s electrical system While observing the fuse requirements specified above connect the power cable as close as possible to the actual battery terminals of the vehicle When available always connect to unswitched terminals in vehicle fuse panel after providing proper fusing ATTENTION For uninterrupted power electrical supply connections should not be made at any point after the ignition switch of the vehicle If used connect the wiring for the blackout screen box Use proper electrical and mechanical fastening means for terminating the cable Properly sized crimp type electrical terminals are an accepted method of termination Please select electrical connectors sized for use with 18AWG 1mm conductors Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals taking care not to over tighten and pinch conductors or penetrate outer cable jacket E EQ TX8000GWW D ARC User Manual Tx800 Installation 4 2 2 DC to DC Converter Connect the brown part of this cable to positive and the white part to negative on the power source DC DC converter and fuse it as shown below EXISTING CIRCUITRY ON VEHICLE TRUX COMPUTER FORKLIFT BATTERY MAIN SWITCH es S 5A slow fuse Close to power source Do not connect Circular Power Connector ISOLATED DC DC Supplied Power Cable Shielding to be trimmed Figure 7 Wiring Diagram With
35. rain relief according to fig 8 for USB and PS 2 connectors 24 E EQ TX8000GWW D ARC User Manual Tx800 Installation Figure 10 Strain relieving brackets for USB and PS 2 connectors When all peripherals are connected the cabling should be put in the openable cable protection tube delivered with the unit described in section 4 5 4 4 2 Supplying power to peripherals Some peripherals require power from the computer s COM or Multi Purpose port for example a bar code reader or an illuminated keyboard You can configure the Tx800 as follows e 12V power is supplied from pin 9 on the COM 2 port e 5V power is supplied from pin 9 on the COM 1 port e 12V power is supplied from pin 5 on the Multi purpose port Peripherals with maximum power consumption of 300 mA can be supplied from these ports Use the Trux Computer Manager to configure activation of the power supply from ports Please refer to the Trux Configuration Guide available on the documentation CD for details on using the Trux Computer Manager 4 4 3 Keyboard and mouse Tx800 supports either USB or PS 2 connected keyboard and mouse Connect keyboards and pointing devices to the computer s port Use strain relief according to fig 8 section 4 4 1 Note that some require an adapter and others may need additional configuration Follow the instructions for the type of keyboard that you have 4 4 4 Printers You can connect printers to either e COM ports see Fig 7 pos
36. that organisation should be informed of the following contents e Li Po battery e Circuit boards and circuits e Screen LCD and glass e Metal casing magnesium e Cables E EQ TX8000GW W D ARC 53 Appendix User Manual Tx800 IX Batteries CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions DISCHARGED BATTERY Disposal of a Li Po battery poses a smaller threat to the environment when compared to other battery types However all used Li Po batteries should be sent to a qualified battery collection centre for recycling Remember to return old batteries for recycling 54 E EQ TX8000GWW D ARC User Manual Tx800 Appendix X Fran ais Avertissement et emarque Le manuel n explique pas comment installer et utiliser le syst me d exploitation ou les applications Avertissement Vous avertit des risques de dommages pour les individus ou les biens Suivez toujours les instructions qui figurent en regard de ce symbole Remarque Attire votre attention sur les probl mes qui peuvent survenir si une mesure n est pas prise ou est prise de mani re incorrecte Soyez toujours prudent lorsque vous travaillez avec l lectricit Ne mettez jamais l ordinateur sous tension si les conditions environnementales ne sont pas dans les limites indiqu es cf Annexe I Sp cifications Par exemple v rifiez que l ordinateur est mis sous
37. types of support agreements are available for Tx800 Contact kerstr ms Trux AB for more information E EQ TX8000GW W D ARC 33 Maintenance User Manual Tx800 34 E EQ TX8000GWW D ARC 7 Troubleshooting Perform the following troubleshooting procedures before contacting Akerstr ms Trux regarding problems with Tx800 7 1 Computer problems 7 1 1 The computer will not start If nothing happens when the On Off button is pressed ensure that the e Power supply is connected On Off LED blinking green e Fuseis intact DC DC converter supplies correct voltage e LED Indications on the front panel are correct section 5 2 4 7 1 2 The screen is blank If the computer is on but the screen is blank or is only faintly lit ensure that the e Screen black out dim function is not active fast green blinking On Off button e Screen s brightness is not set too low Adjust with the brightness control buttons on the front e LED Indications on frontpanel are correct see section 5 2 4 Try attaching an external VGA monitor if nothing else works E EQ TX8000GW W D ARC 35 Troubleshooting User Manual Tx800 7 2 Problems with peripherals If a peripheral doesn t work e Check cabling contacts and connections first e the peripheral needs power supply make sure the power supply for peripherals is activated in the Trux Computer Manager 7 2 1 Keyboard Mouse If keyboard or mouse doesn t work
38. ved including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Warning Changes or modifications to this device not expressly approved by LXE Inc could void the user s authority to operate this equipment EMC Directive Requirements This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Cet appareil num rique de la classe A respecte toutes
39. y reading section 7 Troubleshooting If the problem cannot be solved check with the person in charge at your company to see whether there are support agreements for your Tx800 Then contact Akerstr ms Trux AB kerstr ms Trux AB only offers support for Windows XP and Windows XP Embedded operating systems in the Tx800 Service After repairs or service if possible the computer will be returned with operating system and software in the same condition as when it was sent to Akerstr ms Trux AB Otherwise it will be returned with the original configuration unless other agreements have been made E EQ TX8000GWW D ARC User Manual Tx800 Appendix Vill Environmental Care Information Thanks to its low energy consumption the use of Tx800 has a minimal effect on the environment However the computer should still be turned off or put on standby when it is not in use to avoid the unnecessary consumption of energy Information on recycling Since the computer contains materials that can harm the environment if handled improperly a disused computer should always be taken to a recycling depot for electronic waste Akerstr ms Trux AB is happy to take back disused computers and will ensure that they are recycled in accordance with sound environmental practice Contact Akerstr ms Trux AB for more information Contents that may be harmful to the environment If the computer is sent in for recycling anywhere else than Akerstr ms Trux AB