1. HEAT AND COOL RC RH JUMPER PROVIDED SYSTEM COMMON TYPICAL 2 TRANSFORMER 24VAC 5 WIRE HOOKUP SINGLE STAGE HEAT AND COOL W 0 B G RC RH D RC RH JUMPER REMOVED T15VAC 115VAC CUSTOMER RC RH JUMPER SUPPLIED PROVIDED JUMPER SYSTEM COMMON REVERSING COMPRESSOR VALVE CONNECT TO EITHER B R ngi BUT NOT BOTH SYSTEM XFMR 115VAC WIRING DIAGRAM NOTES 1 The BOLD lines are what you should be connecting to the terminals on this new thermostat 2 The DASHED lines are optional depending upon your system type 3 In many cases the thin lines shown as SYSTEM COMMON will not be visible at the thermostat location they are located with your heating and cooling equipment 4 For Heat Pumps use the B or O wire NOT BOTH Typically neither are used in a conventional system 5 If Y and C wires are both present then C is a common wire Tape it off 6 If you have a B wire in your system which is used as a common wire tape it off Connecting it to the B terminal on this thermostat may damage your system and or the thermostat COMPLETING YOUR INSTALLATION 7 See the SETUP OPTIONS section to configure the thermostat s options NOTE Before use remove the plastic film that is protecting the LCD display screen 8 Install two 2 Energizer or DURACELL AA size Alkaline Batteries at this time For instructions on installing th
2. ATTERIES The CAG111 requires batteries to be able to operate your heating or cooling system Replace the batteries when the LO Battery REPLACE indicator appears in the display or At Least Once A Year 1 To access your unit s battery location remove the front half of the thermostat from its base plate by applying opposite pressure on the two thumb tabs located on the bottom edge of the thermostat and separate the unit 2 The battery tray is located adjacent to the circuit board 3 Remove the used batteries from the battery tray if present and install two new Energizer or DURACELL AA size Alkaline Batteries into the battery compartment Observe the correct polarity markings shown in the compartment 4 Install your CAG111 thermostat back onto its base plate To do this line up the tabs on all four corners and gently push the unit straight onto the base Do not use unnecessary force if the body does not snap into place easily Remove the body line it back up and try again TECHNICAL ASSISTANCE If you have any problems installing or using this thermostat please carefully and thoroughly review the instruction manual again If you require assistance please contact our Technical Assistance Department at 856 234 8803 during regular business hours between 8 00AM and 4 30PM Eastern Standard Time Monday through Friday You can also receive technical assistance online anytime day or night at http www luxproducts com Our web site offers you
3. CTIONS SYSTEM MODE SWITCH The MODE switch has three positions HEAT OFF and COOL In the winter set the mode switch to HEAT to control your heating system in the summer set the switch to COOL to control your air conditioning In the spring and fall or when the windows are open you can set the switch OFF When the switch is in the HEAT position the word HEAT will be displayed next to the temperature When the switch is in the COOL position the word COOL will be displayed next to the temperature Either of these indicators will be flashing if the system is currently running or on steady if the system is not currently running NOTE When the system mode switch is in the OFF position it is normal for the system s blower fan G terminal if used to still become activated depending upon the position of the FAN mode switch see below FAN MODE SWITCH The FAN switch has three positions AUTO CLEAN and ON Whenever the fan is commanded on by the thermostat the word FAN will flash on the LCD display e In the AUTO position the operation of the blower fan is determined only by the on off cycling of the heating and cooling systems e When the FAN switch is in the CLEAN position this will enable the IAQ Clean Cycle Patent Pending feature This will assist in improving Indoor Air Quality by circulating and filtering the air by using the system s blower fan on a timed basis Your heating and cooling systems will still w
4. Complete Easy To Read INSTALLATION AND OPERATING INSTRUCTIONS ly CAG111 SERIES SMART TEMP DIGITAL THERMOSTAT Installs Easily Choose Heat or Cool Set Temperature LUX PRODUCTS CORPORATION Mt Laurel New Jersey 08054 USA 43384 WARNING Use Energizer or DURACELL Alkaline Batteries Only Energizer is a registered trademark of Eveready Battery Company Inc DURACELL is a registered trademark of The Gillette Company Inc IMPORTANT Please read all instructions carefully before beginning installation and save for future reference Before removing any wiring from your existing thermostat the wires must be labeled with their terminal designations Ignore the color of the wires since they may not comply with any standard Thank you for your confidence in our product To obtain the best results from your investment please read these instructions carefully and thoroughly You should become fully acquainted with this thermostat before installing it for usage Follow the installation procedures carefully and one step at a time This will save you time and minimize the chance of damaging either the thermostat or the systems that it controls These instructions may contain information beyond that required for your particular installation Please save these instructions for future reference COMPATIBILITY The CAG111 can be used with most single stage 24 volt gas oil or electric heating and air conditioning systems s
5. PATENT PENDING LUX s Clean Cycle Patent Pending allows you to enable a forced air system to periodically flow air through your system s filter cleaning the air in your home even when heating or cooling is not being utilized In CLEAN mode the fan maintains the pre programmed minimum run time of fifteen 15 minutes per hour it may run additional time as required to maintain temperature control The algorithm used avoids additional fan run time when the 15 minute minimum has been met over the last hour through temperature control Minimum fan run times are met by running one third of the hourly requirement at twenty 20 minute intervals The minimum fan run time is 15 minutes per hour INSTALLATION PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION CAUTION Turn off electricity to the appliance before installing or servicing the thermostat or any part of the system Do not turn the electricity back on until the work is completed e Your thermostat is a precision instrument Please handle it with care e Do not short jumper across the electric terminals on either the furnace or air conditioner to test the system This may damage the thermostat and void your warranty e All wiring must conform to all applicable local codes and ordinances e This thermostat should be limited to a maximum of 1 5 amps higher current may cause damage to the thermostat TOOLS REQUIRED e 1 Phillips screwdriver medium
6. answers to the most common technical questions and also permits you to email your questions to our technical support staff at your convenience WARRANTY Limited Warranty If this unit fails because of defects in materials or workmanship within one year of the date of original purchase LUX will at its option repair or replace it This warranty does not cover damage by accident misuse or failure to follow the installation instructions Implied warranties are limited in duration to one year from the date of original purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Please return malfunctioning or defective units including the batteries that were being used to the participating retailer from which your purchase was made along with proof of purchase Please refer to the Technical Assistance section before returning thermostat Purchaser assumes all risks and liability for incidental and consequential damage resulting from the installation and use of this unit Some states do not allow the exClusion of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Applicable in the U S A only
7. both the furnace and air conditioner then proceed with the following 2 Remove cover from old thermostat Most are snap on types and simply pull off Some have screws on the sides these must be loosened first 3 Take note the letters printed near the wire terminals Attach labels enclosed to each wire for identification by terminal letter not color 4 Make sure the wires do not fall back inside the wall and remove and label one wire at a time 5 Loosen all screws on the old thermostat and or base and remove it from the wall MOUNTING THE CAG111 1 Strip insulation leaving 3 8 in 9 5mm of bare wire on the ends and clean off any corrosion present 2 Fill the wall opening with non combustible insulation to prevent drafts from affecting the thermostat CAUTION Be careful not to drop the body or disturb any of the electronic parts 3 Pull your new thermostat apart by opposite pressure on the two thumb tabs located on the bottom edge of the thermostat to separate the unit NOTE If you are mounting the base to a soft material like plasterboard or if you are using the old mounting holes the screws may not hold Drill a 3 16 in 4 8mm hole at each screw location and insert the plastic anchors provided Then mount the base as described below 4 Hold the base against the wall Route the wires through the larger hole adjacent to the terminal block Position the base for best appearance to hide any marks from an
8. e Drill with 3 16 in 4 8mm drill bit e Wire stripper cutter THERMOSTAT LOCATION On replacement installations mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise On new installations follow the guidelines listed below 1 Locate the thermostat on an inside wall at about 5 ft 1 5m above the floor and in a room that is used often 2 Do not install it where there are unusual heating conditions such as direct sunlight near a lamp television radiator register fireplace on a wall opposite a stove or that carries hot water pipes 3 Do not locate in unusual cooling conditions such as on a wall separating an unheated room or in a draft from a stairwell door or window 4 Do not locate where air circulation is poor such as in a corner or alcove or behind an open door 5 Do not locate in a damp area This can lead to corrosion that may shorten thermostat life 6 Do not install the unit until all construction work and painting has been completed CAUTION e Read all instructions carefully before removing any wiring from existing thermostat e Wires must be labeled by their terminal letters before they are removed e Do not allow wires to touch each other or parts on thermostat e When removing wires from their terminals ignore the color of the wires since these may not comply with any standard REMOVING THE OLD THERMOSTAT 1 Switch OFF the electricity to
9. e batteries see the BATTERIES AND MAINTENANCE section 9 Install your CAG111 thermostat onto its base To do this line up the tabs on all four corners and gently push the unit straight onto the base Do not use unnecessary force if the body does not snap into place easily Remove the body line it back up and try again 10 Turn the electrical power back ON to both your heating and or air conditioning systems 11 Verify that both systems and the blower fan are operating properly When set to a high temperature the heating system should provide warm air after a short time in Heat Mode Likewise a cooling system should provide cool air after a short time when set to a low temperature in Cool Mode Usually sound from the furnace and air conditioning units can be heard while either of them is running The rush of moving air should be heard within a short time after either has been started 12 Your installation is now complete NOTE If you have an Electric Heat system and the blower does not operate after installation locate the Gas Electric option inside the back of the thermostat Move the jumper to the Electric position SETUP OPTIONS NOTE This thermostat is able to be installed and used without changing the items in this SETUP OPTIONS section These are optional and are provided to meet your personal preferences HARDWARE RESET The Hardware RESET button restarts your thermostat s internal programming and th
10. ecommended filter usage amount up to 100 percent over To reset the filter counter after replacing your filter either press and hold the FILTER button for at least three 3 seconds OR press the FILTER button once and then the UP or DOWN buttons to change to a different filter duration setting DISPLAY ILLUMINATION Pressing the LIGHT button will illuminate the display for easier viewing in dim light conditions The light will remain on for approximately 10 seconds While the light is illuminated pressing any of the four push buttons will continue the lighting and remain on for approximately 10 more seconds USER TEMPERATURE CALIBRATION lf the ambient temperature displayed on the LCD screen does not exactly match a nearby thermometer or perhaps another thermostat in the home the user has the ability to adjust or shift the displayed temperature The displayed temperature can be altered by up to 5 F or 3 C in either direction This adjustment is performed by first placing the System Mode switch to the OFF position then by pressing and holding both the UP and DOWN buttons together for at least two 2 seconds the lower red portion of the screen will display the word SET and the default selection of zero 0 Press either the UP or DOWN buttons for the associated direction of change Note If no buttons are pressed within four 4 seconds the thermostat will return back to normal run mode BATTERIES AND MAINTENANCE INSTALLING NEW B
11. en returns the unit back to normal operation A press of this button is required to recognize any jumper setting changes performed at the back of the thermostat on the circuit board This reset is a white button located inside on the back of the thermostat on the circuit board It is labeled RESET JUMPER SETTINGS There are five 5 headers or jumpers located inside the thermostat at the rear of the circuit board These settings can be changed from their default values by removing its corresponding black jumper cap and reinstalling the cap so that it is positioned on only one 1 of the metal pins and not both A change to ANY of the jumper settings will not be recognized by the thermostat until a HARDWARE RESET is performed An OPEN jumper means the cap is only on one 1 metal pin and a CLOSED jumper means the cap is on both of the metal pins Each of these jumpers changes a different JP1 option the choices for these options are listed JP2 in a table printed on the circuit board JP3 A table similar to this one shown here is JP4 printed on the thermostat s circuit board JP5 There may be minor differences in some of the wording of your specific model but the function of each option will be the same JP1 5 OR 2 MINUTE MINIMUM RUN OFF TIMES This setting changes the minimum length of time that the heating or cooling system must remain either on or off before it will automatically switch to the alternate on or off sta
12. ing either the UP or DOWN button once per degree of change or by holding either button down for at least two seconds to automatically increment the set point quickly in the associated direction AIR FILTER LIFE COUNTER The air filter monitor feature tracks the total amount of fan run time to calculate the estimated remaining life of the filter or recommended calendar days The LCD display shows the remaining filter life in an easy to view bar graph that can be set to display either days remaining or percent remaining refer to the SETUP OPTIONS section for instructions on changing options for this feature The default filter life is ninety 90 days This duration may be altered by pushing the FILTER button on the front of the thermostat and using either the UP or DOWN buttons to cycle through the available choices of 000 30 60 90 or 120 days A selection of 000 will disable the filter counter completely and remove the bar graph from the display When the filter usage timer has counted all the way down it will indicate the need for filter replacement by displaying a flashing red box containing the words FILTER CHANGE If you are in the DAYS mode which is default the LCD will count down to zero 0 and then back upwards to indicate the amount of days over the recommended filter replacement time If you are in the percent mode the LCD will count down to zero 0 and then back upwards to indicate the amount of percentage over the r
13. ingle stage heat pumps or gas Millivolt heating systems It cannot be used with 3 wire zone valves 120 volt heating systems or multi stage heat pumps Ask your dealer for other LUX thermostats to control those systems FEATURES Large Easy to Read EL Electro hee FanSlide_ att bac att spa Switch r U7 1 es T Temperature E on Change Buttons bays Lert 79 Filter Button HEAT AULIN Mode Side fgg Switch cooL Light Button Graphical Filter Monitor amp Indicator e 1 Stage Heat 1 Stage Cool e Electronic Digital Non Programmable e IAQ Clean Cycle Patent Pending e Separate Filter Button e Gas Electric Blower Option e Battery Powered e Setting Temperature Range 45 F to 90 F e Clean Attractive Design e Easy To Install e EL Electro Luminescent Backlight Display e Comprehensive Graphical Filter Life Monitor in Days or Percent e Large Easy To Read Dual Color Display e F C Selectable Temperature Display e Adjustable Temperature Differential Cycle Rate e User Temperature Offset Display Calibration e 5 2 Minute Selectable Minimum Run Off Time for Short Cycle Compressor Protection On Screen Low Battery Indicator 1 Year Warranty CAUTION The CAG111 is protected against normal static electric discharges However in extremely dry weather you should touch a grounded metal object before touching the CAG111 to minimize the risk of causing damage to the unit CLEAN CYCLE
14. old thermostat Attach the base to the wall with the two screws provided CONNECTING THE WIRES 5 Clean bare wire ends must be inserted between the black clamp plate and the brass terminal 6 Securely tighten all electrical terminal screws even unused ones The diagrams below are provided for new installations or for unreferenced wires HEATING ONLY SYSTEMS COOLING ONLY SYSTEMS RC RH JUMPER RC RH JUMPER PROVIDED PROVIDED Y W 0 B G RIRH Y W O B G RCIRH HEATING COOLING SYSTEMS 4 WIRES WITH ONE TRANSFORMER HEATING COOLING SYSTEMS 5 WIRES WITH TWO TRANSFORMERS RC RH JUMPER PROVIDED Y W 0 B G RCIRH RC RH JUMPER REMOVED Y W O B G RCIRH TYPICAL SINGLE STAGE HEAT PUMP WIRING CUSTOMER SUPPLIED RC RH JUMPER JUMPER PROVIDED Y w 0 BG ACIRH CAUTION ALL COMMON WIRES MUST BE TAPED OFF f a B wire in your system is a system common tape it off Connecting it to the thermostat s B terminal may damage your system or the thermostat f Y and C are both present C is acommon wire DO NOT USE IT TAPE IT OFF TYPICAL 2 OR 3 WIRE HEAT HOOKUP l 24V AC SYSTEMS OPTIONAL RC RH JUMPER FAN LEAD PROVIDED SYSTEM COMMON TYPICAL COOL HOOKUP 24V AC SYSTEMS 0 RC RH JUMPER PROVIDED SYSTEM COMMON SYSTEM COMPRESSOR in T15VAC TYPICAL 24V AC 4 WIRE HOOKUP SINGLE STAGE
15. ork as they normally would This Clean Cycle feature will ensure that the blower fan will run for a minimum of fifteen 15 minutes per hour every hour even if there is no demand for either heating or cooling system activation this includes when the System Mode Switch is in the OFF position The 15 minute required run time is accomplished by monitoring the amount of time the heating or cooling system has already run the fan within the past hour based upon a total of three 20 minute segments If the required 15 minutes per hour of run time has already been met by running either the heating or cooling there will be no additional fan run time made by the Clean Cycle feature e When the FAN switch is in the ON position the system s blower fan will be commanded ON and remain ON while the FAN switch is in the ON position this also includes when the System Mode Switch is in the OFF position NOTE The FAN switch only works if your system provides a wire for the CAG111 s G terminal PUSH BUTTONS There are four push buttons to the right of the unit s display screen These are used to adjust the set point temperature modify the values for user changeable options select the filter duration and illuminate the attractive screen s backlight feature TEMPERATURE ADJUSTMENT While in HEAT or COOL mode a single press on either the UP or DOWN button causes the set point to start flashing Once flashing the set point can be altered by press
16. te The purpose of this feature is to provide air conditioning compressor protection by preventing brief or undesirable on off cycling JP2 FAHRENHEIT OR CELSIUS DISPLAY FORMAT This setting controls whether the temperature is displayed in degrees F or C on the LCD screen JP3 TEMPERATURE SWING SETTING This setting changes the size of the temperature control band with respect to the set point The larger the swing setting the larger the temperature control range will be Conversely the smaller the swing setting the smaller or tighter the temperature control range will be This setting is called NARROW and WIDE JP4 GAS ELECTRIC FAN OPERATION This setting changes whether the system s blower fan if applicable is controlled by the thermostat in HEAT mode Choose ELECTRIC if you have electric heating and require the thermostat to control the fan Choose GAS if you have a gas heating system this will allow the furnace itself to control the operation of the blower fan JP5 DAYS HOURS FILTER LIFE COUNTER This setting will determine how the remaining filter life will be displayed on the screen In the DAYS setting the screen will count down the number of calendar days remaining before a filter change is recommended In the setting the screen will count down the amount of percentage of air filter life remaining before a filter change is recommended Either option will display the visual bar graph OPERATING INSTRU
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung TVOC V4.2 VAIO Notebook User Guide - Manuals, Specs & Warranty Speaker System Active Subwoofer User Manual Transceiver Module TCM 310 / TCM 310C / TCM 310U Karcher G 2600 OR User's Manual Savo I-6309-S2 Untitled - Brutal Deluxe le congé paternité, mode d`emploi Copyright © All rights reserved.