Home

LG Electronics 3828A22005P Air Conditioner User Manual

image

Contents

1. electric shock a Install the panel and the Always install a dedicated Use the correctly rated cover of control box circuit and breaker breaker or fuse securely There is risk of fire or electric Improper wiring or installation There is risk of fire or electric shock may cause fire or electric shock shock Owner s Manual 3 Safety Precautions Do not install remove or re install the unit by yourself customer There is risk of fire electric shock explosion or injury Do not modify or extend the power cable There is risk of fire or electric shock For installation always contact the dealer or an Authorized Service Center There is risk of fire electric shock explosion or injury Do not install the product on a defective installation stand It may cause injury accident or damage to the product AN Be cautious when unpacking and installing the product Sharp edges could cause injury Be especially careful of the case edges and the fins on the condenser and evaporator Be sure the installation area does not deteriorate with age If the base collapses the air conditioner could fall with it causing property damage product failure and personal injury E Operatio Take care to ensure that power cable could not be pulled out or damaged during operation There is risk of fire or electric Do not let the air conditioner run for a lo
2. 3 Insert new air purifying filter 24 Cassette Type Air Conditioner When the When it is not going to be used for along time 1 Operate the air conditioner at the following settings for 2 to 3 hours Type of operation Fan operation mode Refer to page 18 This will dry out the internal mechanisms 2 Turn off the breaker when the air conditioner is not going to be used for a long time Dirt may collect and may cause a fire CAUTION Turn off the breaker Helpful information The air filters and your electiric bill If the air filters become clogged with dust the Maintenance and Service When the air conditioner is to be used again 1 Clean the air filter and install it in the indoor unit Refer to page 24 for cleaning it 2 Check that the air inlet and outlet of 2 the indoor outdoor unit are not blocked Check that the ground wire is 3 connected correctly It may be connect to the indoor unit side cooling capacity will drop and 696 of the electricity used to operate the air conditioner will be wasted Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Clean the air filter regular
3. clean the filter After cleaning the filter press the Timer button and button of wired remote controller at the same time for 3 sec Then filter sign LED is OFF Press the On Off button The unit will respond with a beep Open the door on the remote control Press the PLASMA air purifying operation ON OFF button Operation will start when the button is pressed and stop when the button is pressed again Set the fan speed again with door of the remote control closed You can select the fan speed in four 6 steps low medium high or Auto Each time the button is pressed the fan speed mode is shifted 22 Cassette Type Air Conditioner Maintenance and Service Bj Maintenance and Service Indoor Unit Grille Case and Remote Control O Turn the system off before cleanining To clean wipe with a soft dry cloth Do not use bleach or abrasives NOTICE Supply power must be disconnected before deaning the indoor unit Air Filters The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary W Never use any of the followings Water hotter than 40 C Could cause deformation and or discoloration Volatile substances Could damage the surfaces of the air conditioner Mf ooo 7 Ceancen Ey bacteria filter Controller 1 Remove the Air filters W Take hold of the tab and pull slightly forward t
4. P5 c Press the right arrow button and Auto Swing button to finish the setting 4 c Q C Press the left arrow button and Auto Swing button for three seconds in order to set the other two louvers Next procedure is the same before lt qz 7 Hour T ED Although the air conditioner is turned ON OFF the previous setting position is not changed If you want to set the default position you have to set the PO Because the default is the po 20 Cassette Type Air Conditioner Operating Instructions Auto Swing lV Press the On Off Press the Auto Swing Press again the Auto button button then the Swing button to Confirm the unit horizontal ie cancel the on operation louvers swing Auto Swing mode up and down automatically AUTOSWING OPERATION SET TEMP FANSPEED GUSFINCTION This is the Function that any children cannot used to the air conditioner Operation procedure 7 To set the Child Lock Function Press the Timer button and Minute Set button for three seconds Then the operation mode shift to child lock mode and it is displayed CL in the operation display When you press any button in this time the remote controller is not converted to any selected mode and the CL is displayed in the remote controller for about three seconds But the Room Temperature function is operated in spite of child lock mode To ca
5. are no obstructions between the remote controller and the signal receptor Do not drop or throw the remote controller Do not place the remote controller in a location exposed to direct sunlight or near the heating unit or any other heat source Block a strong light over the signal receptor with a curtain or etc so as to prevent the abnormal operation ex electronic quick start ELBA inverter type fluorescent lamp 10 Cassette Type Air Conditioner Operating Instructions Set the Cu Unless you press any button about 5 sometimes 10 seconds while setting function the setting mode returns to initial mode Press the button Hour Each time the button is pressed the number is changed from UG to 23 This number indicates current hour 4 OPERATION SET TEMP FAN SPEED SUB FUNCTION Hour a For example if it is 14 25 press O button 14 times Hour Press the button Min Each time the button is pressed the number increases from UU to 59 This number indicates current minute OPERATION SET TEMP FAN SPEED SUB FUNCTION mm Min al t For example if it is 14 25 press O button 25 times Min 3 Press aj button Each time the button is pressed a day of the week is shifted from sunday to saturday OPERATION SET TEMP FAN SPEED SUB FUNCTION Week Time Er wm Te W Tu Fi Se For example if today is W
6. button Pe Te We M Fi Se Tee 03 05 07 w 11 13 15 17 19 21 23 Week 2 Press the Week button AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Select the Tuesday Bomar em Wi m HOS Holiday 3 Press the Holiday button UTO SWNG OPERATION SET TEMP FRNSPEED GUBFUNCTION Then the remote controller will be displayed fig The outside rectangular means holiday amp You cannot set the weekly program for a holiday Timer Setting If you want to turn it ON during OFF mode or turn it OFF during ON mode you can use timer setting function Timer 1 Press the Timer button OUO me 2 Press infit rd button then you can control the desired time Q Q Hob Nc es Minis Nee If you press Q button the display panel shows ex mmm 01 03 m It means 3 hours later it will stop while ON mode it will operate while OFF mode Cancel 3 If you want to cancel the timer setting function press the Cancel button a Self diag CH will flash in the remote controller display when a problem occurs Then please contact your dealer Owner s Manual 13 Operating Instructions M TX Cooling Mode 4 Soft Dry Mode 6 Auto Mode A 1 st On Off Button RUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION A 3x ORL OHNO Heater Preheat A x a OO eoo uni 7
7. hours from the time of first operating unit Timer Lights up during Timer operation fm Forced Operation procedures when the remote control Operation can t be used o Outdoor Unit Lights up during outdoor unit operation Operation Signal Receptor Air Outlet 8 Cassette Type Air Conditioner Operating Instructions Name and F AUTO SWING OPERATION SET TEMP FAN SPEED SU m Pope HI ATO Heater Preheat NED amp JET Defrost Humidity c OLO So Fiter Outdoor E 17 2 ENSIS 3 5 in Timer Cancel 2ndF 3k tA is Program Week 3 EJE ENS 5 va 4 sje J em a E j8 1 s 7 J T Operation display 9 Plasma Air Clean Button Displays the operation conditions 2 On Off Button 10 Timer Cancel Button Operation starts when this button is pressed and stops Used to cancel the timer when the button is pressed again 11 Timer Set Button 3 Set Temperature Button Used to set the timer when the desired time is obtained Used to set the temperature when the desired is obtai 12 Week Button temperature is obtaingd Used to set a day of the week FAN Operation Button 9 Used to circulate room air without cooling 13 Siem ite 2 Fan Speed Jet Cool Button Used to set the desired fan speed or select Jet cool 14 Holiday Button mode Used to set a holiday of the week Operation Mode Selection Button 15 Time Set Button m Used
8. to select the operation mode Used to set the time of the day and change the time in Auto Operation Mode the weekly timer Function Cooling Operation Mode 16 lear B Soft Dry Operation Mode Ui Set and Clear Button Used to set and clear the weekly timer Z Auto Swing Button 17 Swirl Button Used to swing up and down Used to select swirl mode 8 Room Temperature Checking Button 18 Reset Button Used to check the room temperature Used to set the current time and clear the setting time Display temperature can be different from actual room temperature if the remote controller is installed at the place where sun rays are falling directly or the place nearby heat source Owner s Manual 9 Operating Instructions Signal transmitter START STOP BUTTON O Operation starts when this button is pressed and stops T when the button is pressed again 2 OPERATION MODE SELECTION BUTTON es Used to select the operation mode 3 ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature i EE on oS Ga 4 INDOOR FAN SPEED SELECTOR RBBB IRBDB Bn Used to select fan speed in four steps low medium high and CHAOS e c 5 JET COOL oO 5 1 Used to start or stop the speed cooling 6 speed cooling operates super high fan speed in cooling mode 6 AUTO SWING BUTTON i 3 Used to stop or start louver movement and prc set the desired up down airflow direction C 4 7 ON OFF TIMER BUTTONS I
9. Used to set the time of starting and stopping operation 2 emm 10 8 TIME SETTING BUTTONS 7 HENC 9 Used to adjust the time puo ook 12 9 TIMER SET CANCEL BUTTON H Used to set the timer when the desired time is obtained and to 8 EM 17 cancel the Timer operation 8 IASA SAN 18 10 SLEEP MODE AUTO BUTTON 14 Used to set Sleep Mode Auto operation 15 L3 reser 16 11 AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating 12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature V Flip up door 13 PLASMA o l opened Used to start or stop the plasma purification function 14 HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON 3 Operation Mode OPTIONAL Used to set the desired horizontal airflow direction Cooling Operation 15 RESET BUTTON Used prior to resetting time v 16 2nd F Button Auto Operation Used prior to using modes printed in blue at the bottom of 4 buttons 17 AUTO CLEAN OPTIONAL Healthy Dehumidification Operation Used to set Auto Clean mode 18 C TO F SWITCHING BUTTON Used to switch temperature reading from Centigrade to Fahrenheit The wireless remote controller do not operate the swirl mode A CAUTION of handling the Remote Controller Aim at the signal receiver on the wired remote controller so as to operate The remote control signal can be received at a distance of up to about 7m Be sure that there
10. aggesbin sme SER GES Q EX Time 1234 2nd Operation Mode Selection Button 3 Program Week Holiday 3rd Room Temperature Setting Button OOO gt SetiCir 4th Indoor Fan Speed Selection Button 14 Cassette Type Air Conditioner Operating Instructions 1 Press the On Off Button Select Cooling Operation Press the Operation Mode Selection Button Each time the button is pressed the operation mode is shifted in the arrow direction RUTO SWING OPERATION SETTEMP FAN SPEED SUBFUNCTION RUTO SWING OPERATION SET TEMP FAN SPEED SUBFUNCTION RUTO SWING OPERATION SET TEMP FAN SPEED GUEFURCTONJ B Br Cooling Operation Soft Dry Operation Auto Operation 3 Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C by 1 C AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION 1 HI Lh To raise the Temperature i Gv m To lower the Temperature 4 Set the fan speed 6 Operation Display CIXETETETTSESTESRS STONES TOSI CHENNEN Tas CREE D frase cere serre y sem frase eren Cierre y nem B B e Po B a Select the fan speed in six steps high auto power jet super low low medium The display shows high fan speed Each time the button is pressed the fan speed mode is shifted Owner s Manual 15 Oper
11. ating Instructions This mode dehumidifies without overcooling 1 Press the On Off Button 0 Dselect Soft Dry Operation Press the operation Mode Selection Button Each time the button is pressed the operation mode is shifted in the arrow direction KOXA Operation Display RUTO SWING OPERATION SETTEMP FAN SPEED SUEFUNCTON RUTO SWING OPERATION SETTEMP FANSPEED SUEFUNCTON RUTO SWING OPERATION SET TEMP FAN SPEED SUBFUNCTON SH A D f f IG ET H t Cooling Operation Soft Dry Operation Auto Operation 3 During Dry Operation The indoor fan speed is automatically set to the low so the shift of the indoor fan speed is impossible because of already being set to the best speed for Dry Operation by Micom Control 16 Cassette Type Air Conditioner Operating Instructions 1 Press the On Off Button To select Auto Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow Operation Display RUTOSWING OPERATION SET TEMP FANSPEED GUBFINCTON RUTO SWING OPERATION SET TEMP FANSPEED GUBFINCTION RUTO SWING OPERATION SET TEMP FANSPEED GUBFINCTON A g A go CS Cooling Operation Soft Dry Operation Auto Operation The temperature and fan speed are automatically set by the electronic c
12. ed press O button 3 times 4 Press the RESET button If you want to confirm the current time and a day of the week click the Reset button IAN RESET OPERATION SET TEMP FAN SPEED SUBFUNCTION D Owner s Manual 11 Operating Instructions 7 Press the Program button The remote controller is displayed like a picture Then amp and 01 is blinked Program OPERATION SET TEMP FAN SPEED SUB FUNCTION Sr Ws Tue Web T Fi Sal Time 01 03 05 07 09 11 13 15 17 19 21 23 2 Press the button Press O button repeatedly until desired mode appears Week Week For example if you want Thu press button 4 times 3 Select the time you want Press Oor O button then blinking letter is shown Hour Min SET CLR If you press O button then shape appears shape means that five o clock is reserved Using below buttons you can reserve time SET CLR For example the air conditioner is on 6 7 8 and 13 22 o clock OPERATION SET TEMP FANSPEED SUB FUNCTION Time 01 03 08 07 098 11 13 15 17 19 21 28 12 Cassette Type Air Conditioner Operating Instructions Holiday Setting If Tuesday is a holiday in this week you may set a holiday GUTO SWING OPERATION SET TEMP FRNSPEED GUBFUNCTION Program 1 Press the Program
13. isk of explosion or fire f ry a A M Do not open the inlet grill of the When the product is soaked Be cautious that water could product during operation flooded or submerged not enter the product Do not touch the electrostatic contact an Authorized filter if the unit is so equipped Service Center There is risk of physical injury There is risk of fire or electric There is risk of fire electric shock electric shock or product failure shock or product damage Ventilate the product from time to time when Turn the main power off when cleaning or operating it together with a stove etc maintaining the product There is risk of fire or electric shock There is risk of electric shock Owner s Manual 5 Safety Precautions When the product is not be used for a long Take care to ensure that nobody could step time disconnect the power supply plug or on or fall onto the outdoor unit turn off the breaker There is risk of product damage or failure or This could result in personal injury and product unintended operation damage fA A x ED medi x y A CAUTION B Installation Always check for gas Install the drain hose to Keep level even when refrigerant leakage after ensure that water is drained installing the product installation or repair of product away properly Low refrigerant levels may cause A bad connection may cause To avoid vibration or wate
14. ly Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects Clean at least once every two weeks Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Ventilate the room occasionally Since windows are kept closed itis a good idea to open them and ventilate the room now and then Owner s Manual 25 Maintenance and Service Troubleshooting Check the following points before requesting repairs or service If the malfunction persist please contact your dealer Case Explanation See page The air conditioner does not _ Have you made a mistake in timer operation 13 operate Has the fuse blown or has the circuit breaker been tripped The room has a peculiar odor Check that this is not a damp smell exuded by the walls carpet furniture or cloth items in the room It seems that condensation is Condensation occurs when the airflow from the leaking from the air conditioner air conditioner cools the warm room air Air conditioner does not operate This is the protector of the mechanism for about 3 minutes when restart Wait about three minutes and operation will begin Does not cool or heat effectively Is the air filter dirty See air filter cleaning 24 instructions The room may have been very hot when the room air conditioner was first turned on Allow time for it t
15. n the filter every two weeks objects through the air inlet or outdoor units or more often if necessary outlet while the product is operated There is risk of personal injury A dirty filter reduces the efficiency There are sharp and moving parts and failure of product of the air conditioner and could that could cause personal injury cause product malfunction or j b gt Do not drink the water Use a firm stool or ladder Replace the all batteries in the drained from the product when cleaning or remote control with new ones of maintaining the product the same type Do not mix old and new batteries or different types of batteries Itis not sanitary and could cause Be careful and avoid personal There is risk of fire or explosion serious health issues injury Do not RR or disassemble the batteries If the liquid from the batteries gets onto your Do not dispose of batteries in a fire Skin or clothes wash it well with clean water Do not use the remote if the batteries have leaked The chemicals in batteries could cause burns or other health hazards m They may burn or explode Owner s Manual 7 Operating Instructions Bj Operating Instructions Indoor Signal Receiver E Receives the signals from the remote control Signal receiving sound two short beeps or one long beep Cassette Type Indoor Unit D On Off Lights up during the system operation Filter Sign Lights up after 2400
16. ncel the Child Lock Function lock mode is cancelled and the preselected mode is displayed in the remote controller Helpful information Fan speed and cooling capacity The cooling capacity indicated in the specification is the value when the fan speed is set to high and the capacity will be lower at low or medium fan speed High fan speed is recommended when you wish to cool the room quickly Owner s Manual 21 Operating Instructions Forced Operation Operation procedures when the remote control can t be used Press the tact switch Forced operation for 2 seconds If you want to stop operation press again the tact switch In case the power comes on again after power failure on the Forced Operation mode the operating conditions are automatically set as follows During Forced Operation the initial mode continues Forced operation Tact switch i Heat pump Model Cooling Model Room Temp gt set Temp 2 C Room Temp lt set Temp 2 C Operating mode Cooling Cooling Heating Indoor FAN Speed High set available set available Setting Temperature 22 C set available set available Auto Restart Funct In case the power comes on again after a power failure Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions 1 Filter sign lamp LED is ON 2 If LED indicating filter sign lamp is ON
17. ng time when the humidity is very high and a door or a window is left open Moisture may condense and wet or damage furniture Do not plug or unplug the Do not touch operate the power supply plug during product with wet hands operation There is risk of fire or electric There is risk of fire or electrical Do not place anything on the power cable There is risk of fire or electric shock Do not place a heater or other appliances near the power cable There is risk of fire and electric 4 Cassette Type Air Conditioner Safety Precautions Do not allow water to run Do not store or use flammable Do not use the product in a into electric parts gas or combustibles near the tightly closed space for a product long time lt may cause There is risk of fire There is risk of fire or failure of Oxygen deficiency could occur failure of the product or electric product When flammable gas leaks If strange sounds or small or Stop operation and close the window turn off the gas and open a smoke comes from product Turn in storm or hurricane If possible window for ventilation the breaker off or disconnect the remove the product from the window before turn the product on power supply cable before the hurricane arrives Do not use the telephone or turn There is risk of electric shock or There is risk of property damage switches on or off fire failure of product or electric shock There is r
18. nvalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only K 2 Cassette Type Air Conditioner Safety Precautions Bj Safety Precautions To prevent injury to the user or other people and property damage the following instructions must be followed W Incorrect operation due to ignoring instruction will cause harm or damage The seriousness is classified by the following indications A WARNING This symbol indicates the possibility of death or serious injury L A CAUTION This symbol indicates the possibility of injury or damage j E Meanings of symbols used in this manual are as shown below D Be sure not to do Be sure to follow the instruction AWARNING B Installation Do not use a defective or For electrical work contact Always ground the product underrated circuit breaker the dealer seller a qualified Use this appliance on a electrician or an Authorized dedicated circuit Service Center There is risk of fire or electric Do not disassemble or repair the There is risk of fire or electric shock product There is risk of fire or shock
19. o cool down Has the setting temperature been set incorrectly 15 17 e Are the indoor unit s air inlet or outlet vents obstructed The air conditioner operation is For a noise that sounds like water flowing noisy This is the sound of freon flowing inside the air conditioner unit For a noise that sounds like the compressed air releasing into atmosphere This is the sound of the dehumidifying water being processed inside the air conditioning unit Crack sound is heard This sound is generated by the expansion contraction of the inlet grille etc due to changes of temperature Remote control display is faint or Has the circuit breaker been tripped no display at all Are the batteries inserted in the opposite and directions 26 Cassette Type Air Conditioner LG P No 3828A22005P Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference
20. o remove the filter be removed do not touch the metal parts of the indoor unit It may cause an injury CAUTION When the air filter is to Clean dirt from the air filter using a vacuum 2 cleaner or washing with water W If dirt is conspicuous wash with a neutral detergent in lukewarm water W If hot water 50 C or more is used it may be deformed 3 After washing with water dry well in the shade W Do not expose the air filter to direct sunlight or heat from a fire when drying it 4 Install the air filter Owner s Manual 23 Maintenance and Service Cleaning The PLASMA filter behind the air filters should be checked and cleaned once every 3 months or more often if necessary After removing the air filters pull slightly forward to remove the PLASMA filter Dip the PLASMA filter into the water mixed with neutral detergent for 20 30 minutes Dry the PLASMA filter in the shade for a day Especially the humidity must be removed perfectly on this parts ea Note the cuts of electric discharge lines Re install the PLASMA filter to the original position CAUTION Don t touch this A PLASMA Filter within 10 seconds after opening the inlet grille it may cause an electric shock ee Replacement Recomended use period About 2 years 1 Open front panel and remove air 4 Reinsert air filter and close front filter panel gt 2 Remove air purifying filter
21. ontrols based on the actual room temperature If you want to change the set temperature close the door on the remote control and press the Room Temperature Setting buttons The cooler or warmer you feel the more times up to two times you should press the button The set temperature will then be changed The temperature can be set within a range of 2 2 by 1 level RUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION n j me ep AUTO e UUT 07 e me Cold Cool Proper Warm Hot To raise the Temperature This indication will be shifted to the initial GIA Auto Mode Display state after 5 seconds To lower the Temperature During Auto Operation 4 You cannot switch the indoor fan speed It has already been set by the Fuzzy rule Qf the system is not operating as desired manually switch to another mode The system will not automatically switch from the cooling mode to the heating mode or from heating to cooling it must be done by manually resetting Q During Auto Operation pressing the chaos swing button makes the horizontal louvers swing up and down automatically If you want to stop auto swing press the chaos swing button again Owner s Manual 17 Operating Instructions FAN Operation Mode 1 Press the On Off Button 2 Press FAN Operation Button 4 AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION BHI Each time Fan Speed button is pressed
22. r failure of product water leakage leakage Do not install the product where the Use two or more people to Do not install the product where noise or hot air from the outdoor unit lift and transport the it will be exposed to sea wind could damage the neighborhoods product salt spray directly It may cause a problem for your Avoid personal injury It may cause corrosion on the neighbors product Corrosion particularly on the condenser and evaporator fins could cause product malfunction or inefficient operation E Operation Do not expose the skin directly to cool air for Do not use the product for special purposes such as long periods of time preserving foods works of art etc It is a consumer air Don t sit in the draft conditioner not a precision ioe al This could harm to your health There is risk of x damage or loss of property 6 Cassette Type Air Conditioner Safety Precautions Do not block the inlet or Use a soft cloth to clean Do Do not touch the metal parts of outlet of air flow not use harsh detergents the product when removing the solvents etc air filter They are very sharp e There is risk of fire electric shock There is risk of personal injury or damage to the plastic parts of the product NT gi CS DF iz fiw It may cause product failure Do not step on or put Always insert the filter securely Do not insert hands or other anyting on the product Clea
23. the fan speed mode is shifted in the arrow direction RUTO SWING OPERATION SET TEMP FRNSPEED GUEFINCTIN Fan speed is high en RUTO SWING OPERATION SETTEMP FANSPEED GUBFUNCTION Fan speed is medium 4 eu J Fan speed is low 610 18 Cassette Type Air Conditioner Operating Instructions Comfort Operatic It is the function for comfort cooling heating operation The diagonal two louvers are opened the more larger than the other louvers After one minute it is opposite Press the On Off Button The unit will respond with a beep RUTOSWNG OFERATON SETTENF FANSPEED GUFFUCTOY Press the Swirl Button to operate Z pp comfort cooling or heating DU Then it will be changed the open angle of two horizontal louvers To cancel the Swirl Mode press the Swirl Button again Program Week Holiday een Oc m Owner s Manual 19 Operating Instructions You can change the open angle to the install situation 1 Press the On Off Button Press the right arrow and auto swing button simultaneously for three seconds Then the display will be toggled like before Detach your finger from buttons at the moment that it is displayed PO in the operation display Press the Auto Swing button again Then it will be changed the open angle of two horizontal louvers from PO to
24. website http www lgservic L LG Cassette Type Air Conditioner sd op JONVdsS3 SIVONV H EL Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 2 EN 61000 3 Norm IMPORTANT oom air conditioner future reference after Cassette Type Air Conditioner Owner s Manual TABLE OF CONTENTS _ J FOR YOUR RECORDS Safety Precautions 3 Write the model and serial numbers here Model Serial Operating Instructions 8 You can find them on a label on the side of each unit Dealer s Name Date Purchased Maintenance and Service 23 E Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues J2 READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for Service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or i

Download Pdf Manuals

image

Related Search

Related Contents

PI-1300 PLC接続マニュアル      Practical 10: Protein dynamics and visualization  取扱説明書    忍1キロ粒剤  Skalli - Doctinews  Operation, Installation, and Service Manual  住宅用火災警報器は、火災を最小限に食止める最終兵器です  

Copyright © All rights reserved.
Failed to retrieve file