1. 16 Diopter Adjustment 17 LCD 18 Measurement 18 Installing err nne 20 Hand Strap einn 21 Adjusting hand strap 21 HOWTO y EFR 21 Notes on carrying 21 Connecting AC Adapter 22 Connection Method 23 Placing Batteries 24 Note on Use 24 Remaining Battery Level Mark 24 Placing Batteries 25 ON I OFF O of Power Switch 26 Turning power switch ON 26 Turning power switch OFF 26 Selecting Measurement Time 28 Internal Sync Measurement Mode Setting 30 Setting Observer 32 Selecting Color Space 34 Selecting Absolute Value ABS 36 Difference DIFF Display Selecting Digit for Chromaticity Display 38 Selecting Lens Type 40 Selecting Single or Continuous Measurement 42 Selecting of Max or Minimum Value Display 44 Opening and Closing of Finder Shutter 46 Setting of Stored Data Protection 48 Setting of Update Method for Memory Channel 50 to Store Measurement Value Buzzer Setting 52 Bac
2. Should error be found in this instrument try corrective actions shown in the following table If this does not help this instrument has possibly been broken Please contact the nearest KONICA MINOLTA SENSING authorized service facility with error number and version of your instrument Version can be identified in procedure on p 116 value in calibration value or target color and that appearing after setting be found by 1 digit ail Symptom Item to Check Corrective Action ie No Refer 1 display on LCD Has AC adapter been Connect AC adapter 23 screen even after power properly plugged to AC is on outlet Has AC adapter been Connect AC adapter 23 connected to this instru ment Is AC power source Use within 10 ofthe 8 within rated nominal voltage Have batteries been Place batteries 25 placed Haven t batteries Replace with new batter 25 drained ies or connect with AC adapter 2 Nothing is visible Isn t lens cap on objec Remove lens through finder tive lens Hasn t ND filter covered Do not use ND filter objective lens except for the case when object to measure is of high luminance Hasn t ND filter covered Do not use ND filter finder except for the case when object to measure is of high luminance 3 Does not accept key Hasn t remote mode Press ESC key to can 99 operation been set cel remote mode Don t you pr
3. 3 Copy from other calibration channel Press either key to select lt CH SETTING gt CH COPY and then ENTER key aT lt COPY TO gt screen appears CH ID NAME COPY CH RESET BREAK ESC le 6231 8 Press either Q or key to select calibration channel to copy from To change calibration channel to copy to press SHIFT key to switch to SHIFT mode or press lt SOURCE gt OK TO COPY or key to select calibration channel to copy to ox enTER 19976 Once copied calibration channel to panes y 03908 copy to cannot be returned to previous lt TO gt status before coping sure to check CHOR lt DEFAULT gt channel number before copying lt SOURCE gt OK TO COPY CHO01 D ENTER LY 100 76 CANCEL ESC roo SFT e 25 9 Press ENTER key DEFAULT PLEASE WAIT appears and the Lv 100 76 value is copied COPY TO screen appears d EHE Basics SOURCE Wherf PLEASE WAIT appears do not OK TO COPY CHO01 Lv 100 76 switch OFF Doing so may break stored data OK ENTER x 0 3945 CANCEL ESC SF e 2 y 0 3998 70 10 You can return to procedure 8 and continue copying other channel Note that original calibration channel appears when you return to measurement screen in procedure 11 lt 0 gt 11 Press ESC key three times to lt LENS gt STA
4. Item CHROMA METER CS 200 Measurement range 0 01 200 000 cd m 0 01 5 000 000 cd m 0 01 20 000 000 cd m Measuring angle 1 Measuring angle 0 2 Measuring angle 0 1 Accuracy 150 cd m for illuminant A L 2 1digit xy 0 002 Measuring angle 1 1 0 01 0 5 cd m for illuminant A L 0 02 cd m 1digit Temperature 23 2 0 5 1 cd m for illuminant A L 0 02 cd m 1digit xy 0 007 RH 6596 max 1 10 cd m for illuminant A L 2 1digit xy 0 004 10 200 000 cd m for illuminant A L 2 1digit xy 0 003 5 000 cd m for illuminant A color filter R G B xy 0 006 Repeatability 0 01 1 cd m for illuminant L 0 01 cd m 1digit 2 AUTO Measuring angle 1 2 1 2cd m for illuminant A L 0 5 1digit xy 0 002 2 o AUTO 2 4cd m for illuminant A 1 0 5 96 1digit xy 0 001 2 o AUTO 4 8 cd m for illuminant A L 0 5 1digit 0 0005 2 o AUTO 8 200 000 cd m for illuminant A L 0 1 1digit xy 0 0004 2 o AUTO Measurement time Measurement method Automatically set between approx 1 sec meas and 60 sec meas AUTO Automatically set to approx 1 sec meas or 3 sec meas LTD AUTO approx 0 5 sec meas Super FAST approx 1 sec meas FAST approx 3 sec meas SLOW approx 12 sec meas Super SLOW Spectral method Grating linear photo diode array Measuring angle 1 0 2 0 1 Switchable Minimum measuring area
5. MEMORY DATA y 0 4477 M sIe e NO DATA 2 Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 40 Press MENU key twice Menu 2 4 screen appears on LCD screen Press either Q or key to select OBJECTIVE LENS and then ENTER key Inversion cursor moves from OBJECTIVE LENS to right to change lens type Press either Q or key to switch lens type If Q is pressed lens type switches in order of STANDARD No 122 No 107 STANDARD Keep pressing to continuously switch If 9 is pressed lens type switches in order of STANDARD No 107 No 122 STANDARD Keep pressing to continuously switch MENU 2 4 STANDARD DISPLAY DIGITS 4 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON BREAK ESC 2 me MENU 2 4 OBJECTIVE LENS DISPLAY DIGITS 4 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON pes MENU 2 4 OBJECTIVE LENS No 107 DISPLAY DIGITS 4 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON BREAK ESC 2 mme Set to No 107 for close up lens No 107 No 122 for close up lens No 122 and STANDARD for nothing with objective lens Press ESC key to stop Press ENTER key Inversion cursor returns to OBJECTIVE LENS Now change has been set Press ESC key to return to m
6. vEM AUTO NUM MEMORY DATA y 04477 Maoa DATA Lv 2 Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 3 Press MENU key twice MENU 2 4 Menu 2 4 screen appears on LCD screen STANDARD DISPLAY DIGITS 4 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON BREAK ESC le 2 4 Press either Q or key to select lt MENU gt 2 4 DISPLAY DIGITS and then ENTER key OBJECTIVE LENS STANDARD Inversion cursor moves from DISPLAY DIGITS DISPLAY DIGITS 4 FIGURES to right to change digits to display MEMORY MODE AUTO NUM DATA PROTECT ON d BREAK TESA 38 5 Press either Q or key to set for either 4 FIGURES or 3 FIGURES Press ESC key to stop Press ENTER key Inversion cursor returns to DISPLAY DIGITS Now change has been set Press ESC key to return to measurement screen Setting remains even after switching OFF O 39 lt MENU gt 2 4 OBJECTIVE LENS STANDARD DISPLAY DIGITS 3 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON BREAK ESC 2 me MENU 2 4 OBJECTIVE LENS STANDARD 3 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON BREAK ESC 2 e LAUS 1 VIEW 2 gt AUTO 0 80 NC 200 00Hz cd m lt L ENS gt STANDARD 0 448 MEM AUTO NUM MEMORY DATA 8 8 DAT
7. 9 key 9 to 0 descending order K M decimal point and space available If kept pressed value continuously changes and M show x10 and x10 respectively See p 71 for details on Numerical value entry ranges Press key to move cursor to second digit position Repeat procedures from 12 to 13 as necessary to enter calibration values for Lv x and y or each value for other color spaces respectively Press ESC key to stop Press ENTER key Afte PLEASE WAIT appears CH SETTING screen appears Wherf PLEASE WAIT appears do not switch OFF Doing so may break stored data Press ESC key twice to return to measurement screen 67 CURRENT DATA Lv 90 30 x 0 4210 y 0 4128 SET CAL VALUE OK ENTER ISFi e 2 USER CAL DATA lt ANGL gt 1 VIEW CH01 lt DEFAULT gt lt SPD gt AUTO lt SYNC gt NO SYNC cd m lt LENS gt STANDARD lt MEM gt AUTO NUM lt CURRENT DATA gt Lv 90 30 x 0 4210 y 0 4128 SET CAL VALUE OK ENTER SFT 2 USER CAL DATA ANGL 1 VIEW CH01 lt DEFAULT gt lt SPD gt AUTO lt SYNC gt NO SYNC cd m lt LENS gt STANDARD lt MEM gt AUTO NUM lt CURRENT DATA gt Lv 90 30 x 0 4210 y 0 4128 SET CAL VALUE OK ENTER SFT 2 lt USER CAL DATA gt lt ANGL gt 1 VIEW CH01 lt DEFAULT gt lt SPD gt AUTO lt SYNC gt NO SYNC Lv 90 08 LENS STANDARD X 0 4215 MEM AUTO NUM y 0
8. There are 100 directories to store measurement value from M000 to M100 and each can store one value 101 in total If memory channel update method has been set for AUTO SAVE measurement value is to store after measurement automatically In case of AUTO NUM or MAN NUM follow below procedure to store measurement value See p 50 Operation Procedure MEMORY ABS DIFF BACKLIGHT KEY LOCK MEAS SPEED il MENU ESC ENTER 1 Make sure that is shown on bottom left of measurement screen indicating it has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 2 Press either Qo or key to select memory channel 90 CH00 lt DEFAULT gt ANGI gt 1 VIEW lt SPD gt AUTO lt SYNC gt 60 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt SPD gt AUTO SYNC 60 00 2 lt MODE gt SINGLE le 2 3 Press MEMORY key CHO1 lt DEFAULT gt lt ANGL 1 VIEW lt SPD gt AUTO If MAN NUM has been set for memory Lv 20 80 channel update measurement value X 0 447 is to store in selected channel y 0 4477 NOS Lv 20 80 x 0 4476 lt MODE gt SINGLE 0 4477 Je fey In case of AUTO NUM measurement CHO01 lt DEFAULT gt lt ANGL gt 1 VIEW value is to store in selected channel Lv 20 80 Sere ATO pote 9 2 and next channel number appears x0 4476 Ern ey y 0447 MEMET a Maximum v
9. during measurement 106 Operation Procedure Without data management software CS S10w Setting Necessary for Object Color Measurement 1 4 Setone or more tungsten lumps __ or equivalent as illumination saute source toward white calibration cae plate as in the right illustration Set this instrument vertical Aas to white calibration plate zt Keep the angle between illumination light source and white calibration plate at 45 Illumination Light Source White Calibration 2 Perform user calibration See p 64 for details Measurement of Object 3 Set object on the same position and at the same angle as white calibration plate 4 Now measurement can be done 107 uonduoseq Operation Procedure With data management software CS S10w Setting Necessary for Object Color Measurement 1 4 Set or more tungsten lumps Lr or equivalent as illumination MEM Light Source S x White calibration plate source toward white calibration plate as in the right illustration e Set this instrument vertical 45 2 to white calibration plate Keep the angle between illumination light source and white calibration plate at 45 Illumination Light Source 2 Start up this instrument PC and software CS S10w White Calibration 3 S
10. 60 5 mm 20 1 mm With close up lens No 107 Minimum measuring distance 296 mm Distance from front edge of metal lens barrel Color space L x y L TAuv XYZ dominant wavelength Measurement synchroniza tion frequency Vertical synchronization frequency 40 00 to 200 00 Hz Interface USB1 1 Power source AC adapter and 4 AA Size Batteries Battery life 3 hours approx in Continuous measurement FAST mode with AA Size bat tery under company testing KONICA MINOLTA SENSING s conditions Size 95 W x 127 H x 334 L mm Weight 1 8 kg without battery Operating temperature humidity range 0 to 40 C RH 85 96 or less at 35 C with no condensation Storage temperature humidity range 0 to 40 C RH 85 96 or less at 35 C with no condensation Standard accessory Optional accessory Lens cap Holding cap CS A24 ND eyepiece filter CS A27 AC adapter AC A23 Data management software CS S10w Standard USB cable 2 m IF A17 Close up lens No 107 Close up lens No 122 ND filter 1 10 CS A6 ND filter 1 100 CS A7 Calibration instruction For ND filter Step up ring 40 5 to 55 mm CS A26 Angle finder Vn White calibration plate For 45 0 CS A20 White calibration plate For d 0 CS A21 White calibra tion plate CS A22 Soft case CS A23 Data management software CS S10w Professional x1 23 Cx2 C Ly 0 01 to 10 cd m SLOW average of 30 measurements L
11. 2 Selects FAST SLOW automatically depending on luminance Luminance for which FAST SLOW is switch able is as follows for measuring angle 1 FAST SLOW Ly 20 cd m or lower Measurement is redone SLOW mode SLOW FAST Ly 40 cd m pt or higher 3 Selects the measurement time automatically depending on luminance For measuring angle 1 when luminance is higher than 20 cd m the measurement time switches as LTD AUTO mode When luminance is 20 cd m or lower the measurement time is calculated depend on luminance as following examples The higher limit is 60 s Ly 20 0 cd m 15 0 cd m 10 0 cd m 6 6 cd m 4 6 cd m Measurement Time 14 s approx 30 s approx 60 s approx Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT KEY LOCK J n n MENU ESC 2 3 1 7 1 Press ESC key when menu or target f lt SPD gt AUTO value setting menu appears lt SYNC gt NO SYNC lt LENS gt STANDARD Measurement screen appears on LCD screen lt MEM gt AUTO NUM lt MEMORY DATA gt 2 6 8 DATA a Make sure that appears on bottom left of measurement screen indicating it has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 28 Press MEAS SPEED key to select measurement speed lt SPD gt switches in order of AUTO LTD AUTO S FAST FAST SLOW
12. Connecting to PC This instrument can be used together with PC for mutual communication Use USB cable 2m IF A17 supplied as standard accessory for this purpose USB cable is allowed to plug unplug while power is on but it is recommended to switch power off in this case Operation Procedure 1 Switch power OFF 2 Left protect cover and connect USB cable to USB connector of this instrument 3 Make sure that USB cable is all seated to USB connector Communication interface in this instrument conforms to USB1 1 Hold USB cable plug in unplugging Do not pull cord part Plug USB cable to fit the connector entry point Any USB port on PC may be usable if there are multiple on PC However normal opera tion may not be secured if used with other USB units than CS 200 98 Remote Mode Remote mode refers to sending command from PC to this instrument with both connected If this instrument is controlled with PC REMOTE MODE appears on PC When this message appears key operation of this instrument is not acceptable except for following cases f measurement button is pressed measurement starts to forward its data to PC in case that measurement button is in valid mode by transferring command from PC to this instrument Use data management software below ESC key is pressed to cancel remote mode Use standard accessory data management software CS S10w Standard for this pur pose See instruction manual
13. MEMORY MEAS SPEED ABS DIFF BACKLIGHT 0 v KEY LOCK O m ESC 2 3 1 10 4 9 1 Press ESC key when menu or target CH00 lt DEFAULT gt 27 value setting menu appears JXSYNC _60 00Hz cd m lt LENS gt STANDARD Measurement screen appears on LCD screen lt MEM gt AUTO NUM lt MEMORY DATA gt Maoa NO DATA Lv 2 Make sure that is shown on bottom left of measurement screen indicating it has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 3 Press MENU key MENU 1 4 Menu 1 4 screen appears on LCD screen CH SETTING MEAS MODE SINGLE SYNC MODE DELETE BREAK ESC e 2 4 Press either Q or key to select lt MENU gt 1 4 SYNC MODE and then ENTER key CH SETTING lt SYNC MODE gt screen appears on LCD screen MEAS MODE SINGLE YNC MODE DELETE BREAK ESC le 2 30 9 6 10 Press either key to move inversion cursor from NO SYNC to SYNC so that light source pulse frequency can be entered Press either Q or key to set arbitrary value Okey 0 to 9 0 to 2 in 100 position in descending order decimal point and space available If kept pressed numerical value continuously increases Okey 9 to 0 2 to 0 in 100 position in ascending order decimal point and space available If kept pressed numerical value continuously becomes small Press e key to move c
14. OVER Luminance of measuring object is higher than avail able measurement range Use ND filter and redo measure ment If symptom does not improve please contact the nearest KONI CA MINOLTA SENSING authorized service facility OFFSET ERROR Zero calibration has not been correctly performed Reset the power and redo meas urement If symptom does not improve please contact the nearest KONI CA MINOLTA SENSING authorized service facility EXCESSIVE LUMI NANCE VARIATION Luminance change for measuring object is large Place this instrument on stable surface and redo measurement If symptom does not improve please contact the nearest KONI CA MINOLTA SENSING authorized service facility VIEWING ANGLE SELECTOR ERROR Measurement was per formed when measurement angle selector was in wrong position or measurement angle selector was changed during measurement Switch measurement angle selec tor and check that measurement angle appears in screen is not displayed and then redo measurement In addition do not operate measurement angle selec tor during measurement If symptom does not improve please contact the nearest KONI CA MINOLTA SENSING authorized service facility ROM ERROR Data stored in ROM is broken Do not switch OFF O side while storing data or changing setting or when message PLEASE WAIT appears If symptom does not improve
15. X 0 448 wEM AUTONUM MEMORY DATA y 0 448 8 8 DATA Lv lt MODE gt SINGLE le 2 57 Buas lt Setting Internal Clock This instrument is equipped with internal clock to record measurement time Although measurement date and time are not indicated in this instrument one can be output together with measurement value when this unit is controlled with PC If used with either standard accessory data management software CS S10w Standard or optional CS S10w Professional measurement time is to display together with measure ment value Ea d Internal clock adjustment has been completed before shipment form factory S Operation Procedure a 5 lt p MEMORY MEAS SPEED ABS DIFF KEY LOCK 10 nd MENU ESC 1 Press ESC key when menu or target CH00 lt DEFAULT gt ES T n value setting menu appears lt SYNC gt 200 00Hz m lt LENS gt STANDARD Measurement screen appears on LCD screen f lt MEM gt AUTO NUM lt MEMORY DATA gt Moo DATA Lv 2 Make sure that appears on left bottom indicating this instrument has been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 3 Press MENU key three times lt MENU gt 3 4 Menu 3 4 screen appears on LCD screen LEEP MODE OFF DATE amp TIME BUZZER VERSION BREAK
16. data 3 Copy from other calibration channel 63 lt Saas v o 1 o m 2 0 Implementing User Calibration User calibration cannot be conducted in calibration channel CHOO serves as calibration channel for measurement based on KONICA MINOLTA SENSING s calibration standard When user calibration is performed in the calibration channel for which target color has already been set previous target color is cancelled These are commonly used among each color space of Lyxy Lyu v LyTAuv XYZ and dominant wavelength in one channel Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT KEY LOCK MENU ESC 2 3 1 10 49 5 4 6 1 Press ESC key when menu or target value setting menu appears Measurement screen appears on LCD screen 2 Press SHIFT key to switch CHWR DEFAULT lt ANGL gt 1 VIEW lt SPD gt AUTO to SHIFT mode lt SYNC gt NO SYNC eo lt LENS gt STANDARD SFT appears on left bottom indicating X MEM AUTO NUM isi i i MEMORY DATA this instrument is to operate in SHIFT NOTA mode Or make sure that SFT appears on left bottom indicating that this instrument has been operated in SHIFT mode 3 Press either Q or key to DEFAULT XANGD 1 VIEW i i i lt SPD gt AUTO switch calibration channel and 1 SERATO 1 lt LENS gt STANDARD select one for user calibration AUTO NUNT lt
17. error Check corrective action If symptom does not improve please 108 message ap for error message contact the nearest KONICA MI pears repeat edly NOLTA SENSING authorized service facility 115 uonduoseq Identifying Version Operation Procedure MEMORY MEAS SPEED ABS DIFF E Made L MENU ENTER 1 Press ESC key when menu or target CH00 lt DEFAULT gt ES T 287 value setting menu appears Lv 20 80 SYNC 200 00Hz cd m lt LENS gt STANDARD Measurement screen appears on LCD screen X 0 4476 lt MEM gt AUTO NUM MEMORY DATA y 04477 Maoa DATA 2 Make sure that appears on bottom left of measurement screen indicating it has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode MENU 3 4 LEEP MODE OFF 3 Press MENU key three times DATE amp TIME Menu 3 4 screen appears on LCD screen BUZZER VERSION le BREAK ESC 2 4 Press either e or key to select VERSION and then ENTER key Such information as version No appears on LCD uonduoseq 116 5 Press ESC key twice to return MENU 3 4 to measurement screen SLEEP MODE OFF DATE amp TIME BUZZER ERSION BREAK ESC le Lee VERSION VER 1 00 0000 S N 0000000 BREAK ESC le 2 CH00 lt DEFAULT gt lt ANGL gt VIEW lt SPD gt AUTO L
18. is recommended at least 1 Measuring low luminance light source object At 2856K Standard light source A as measuring stick 10cd m or lower 1 Aperture 250cd m or lower 0 2 Aperture 1000 cd m or lower 0 1 Aperture 2 Outside room temperature and normal humidity ranges Turning power switch ON 1 Slide power switch to ON 1 side Measurement screen appears 5 seconds after initial screen on LCD Turning power switch OFF 2 Slide power switch to OFF O side after measurement After measurement do not switch OFF until measurement value appears When message PLEASE WAIT appears do not switch OFF either Doing so may break stored data 26 27 Selecting Measurement Time Select measurement time depending on purpose 7 modes are available for measurement time Select the mode with long measurement time when repeated accuracy is required such as when measuring object of low luminance Setting at the shipment from factory AUTO Measurement Time calculated by formula Time for integration Zero Calibration tremor needed for actual measurement indicating exposure time a AST E LOW um m i AUTO X3 1s to 60 s rem MANUAL 1s to 60 s Every 1s __ Zero calibration is performed automatically one minute after previous measurement
19. object ND Filter 1 10 CS A6 ND Filter 1 100 CS A7 e Placed before objective lens for measure ment of high luminance object but sand wich step up ring 40 5 to 55 mm CS A26 inbetween Calibration Certificate For ND Filter e Calibration certificate is available for ND filters 1 10 CS A6 and 1 100 CS A7 Step Up Ring 40 5 to 55 mm CS A26 e Placed before objective lens in using ND filters 1 10 CS A6 or 1 100 CS A7 White Calibration Plate For 45 0 CS A20 White Calibration Plate For d O CS A21 Used for measurement of object colors White Calibration Plate Set CS A22 Aset of white calibration plates For 45 0 CS A20 and For d 0 CS A21 Angle Finder Vn e Connected to finder for easing inconve nience felt in looking into finder in such case as this instrument is set at low posi tion Use supplied adapter to connect Soft Case CS A23 e Used to keep this instrument and accesso ries or carry them with hand Never use for transfer Data Management Software CS S10w Professional e Enables multiple data management thanks to additional functions to that for CS S10w Standard 10 System Configuration Standard accessories mucus Optional accessories AA Size KP Batteries x4 Lens Cap commercially available Angle Finder Vn Step Up Ring Bum 40 5 55mm CS 200 CS A26 ND Eyepie
20. of CS S10w Standard for details on the spec and usage If you want to use independent program in PC to control this instrument download Com munication Specifications from KONICA MINOLTA SENSING s website at URL below for your reference http konicaminolta com instruments download software index html Described URL above is subject to change without notice It the target page will not appear please search the site by keywords CS 200 and download In addition to above tools various data management can be done with CS S10w Profes sional voneolunuwuos 99 100 Principle of Measurement Spectral Fitting Method Konica Minolta s newly developed spectral fitting method provides tristimulus values XYZ red green blue with significantly higher accuracy than that of conventional tris timulus colorimeters This is achieved by using the output from 40 sensors to calculate the spectral response corresponding to human eye sensitivity CIE 1931 color matching functions e The CS 200 uses 40 sensors for sensitivity covering the entire visible region and multiplies each sensor output by appropriate coefficients This adjusts the spectral response of the instrument to close to the CIE 1931 color matching functions n additon to the 2 Standard Observer the 10 Standard Observer for object color measurements can also be selected which is impossible with conventional tristimu lus colorimeters Object is measured
21. of the dominant wavelength The complementary wavelength is determined by extending the line in the opposite direction from the chromaticity point through the white point to the spectrum locus and using the wavelength corresponding to the point of intersection In the example chromaticity point C is in the non spectral region the complementary wavelength is the wavelength corresponding to point SC where the line extended from C through white point N intersects the spectrum locus 104 Spectrum locus White point Pure purple line 380 0 2 0 4 0 6 X Dominant wavelength on chromaticity diagram 105 pm J eo eo Measurement of Object Color This instrument can perform simple measurement by utilizing user calibration function This is also available by using standard accessory data management software CS S10w Standard or optional CS S10w Professional Measured data is evaluated based on lumi nance which has been stored as light source data in CS S10w See instruction manual of CS S10w for details e Set while calibration plate and object on the same position with the same angle from this instrument Uniform illumination and measurement conditions of white calibration plate and those of object If not measurement data may vary causing incorrect data Keep illumination light source as stable as possible with fixed voltage power source
22. please contact the nearest KONI CA MINOLTA SENSING authorized service facility 111 uonduoseq uolduoseg Error message Cause Description Corrective Action 12 MEMORY ERROR Data stored in ROM is broken or backup batteries drain Do not switch OFF side while storing data or changing setting or when message PLEASE WAIT appears e Switch ON side to charge back up battery Backup battery is to fulfill its function after fully charged for approx 20 hours f symptom does not improve please contact the nearest KONI CA MINOLTA SENSING authorized service facility 1 INCORRECT CLOCK OPERATION Clock IC does not operate correctly e Reset the power to set correct date and time If symptom does not improve please contact the nearest KONI CA MINOLTA SENSING authorized service facility 14 A D ERROR Error in AD converter e Reset the power to redo measure ment f symptom does not improve please contact the nearest KONI CA MINOLTA SENSING authorized service facility 15 RECALCULA TION ERROR There exists no measure ment value for recalculation or measurement value be comes lower than measure ment available range after recalculation 112 e Check that measurement value ap pears and redo measurement e Check that user calibration is cor rect and redo measurement
23. retained even after switching OFF O 45 CH00 lt DEF lt ANGL 1 VIEW lt SPD gt AUTO 5 61 lt SYNC gt NO SYNC cd m lt LENS gt STANDARD 0 4125 MEM AUTO NUM MEMORY DATA y 0 4429 lv 0 54 0 4004 lt MODE gt CONT y 0 4123 SFT e 2 CHOO DEP lt ANGL gt 1 VIEW gt lt SPD gt AUTO 15 61 lt SYNC gt NO SYNC cd m lt LENS gt STANDARD x 0 4125 lt MEM gt AUTO NUM MEMORY DATA y 0 4429 Lv 15 61 x 0 4125 y 0 4429 SFe 2 CH00 lt DEF XANGD 1 VIEW VALLEY SPD AUTO V 15 61 lt SYNC gt NO SYNC cd m lt LENS gt STANDARD x 0 4123 lt MEM gt AUTO NUM y 0 4435 on DATA gt Lv 15 61 x 0 4125 y 0 4429 SFe 2 Buas lt gt E T lt AVAd GUS Opening and Closing of Finder Shutter To prevent light from finder from badly influencing measurement internal shutter of finder is to close for every measurement If observation through finder during measurement is required setting can be changed not to close finder shutter In this case light from finder needs to be avoided by looking into finder during measurement Setting at the shipment from factory e automatically closes for every measurement Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT v KEY LOCK Lond MENU ESC ENTER 2 1 3 1 Press ESC key when menu or target CH00 lt DEFAULT gt ose es value setting menu ap
24. same color space as calibration value to be entered in procedures from 12 to 13 Press measurement button to start measurement Now starts measurement This measurement is performed with correction coefficient CH00 based upon KONICA MINOLTA SENSING s calibration standard Measurement value appears on lt CURRENT DATA gt part of LCD screen after measurement is completed After measurement do not switch OFF until measurement value appears Doing so may break stored data 66 lt CH SETTING gt CHO1 lt DEFAULT gt USER CA CH ID NAME CH COPY CH RESET BREAK ESC le 231 lt SPD gt AUTO lt SYNC gt NO SYNC y SELECT MEH DATA OR MEASURE NEXT ENTER e 2 lt USER CAL DATA gt lt ANGL gt 1 VIEW CH01 lt DEFAULT gt lt SPD gt AUTO lt SYNC gt NO SYNC cd m lt LENS gt STANDARD lt MEM gt AUTO NUM HOLD DATA SELECT MEH DATA OR MEASURE NEXT ENTER SFT e 24 lt USER CAL DATA gt lt ANGL gt 1 VIEW CH01 lt DEFAULT gt lt SPD gt AUTO lt SYNC gt NO SYNC cgo cd m lt LENS gt STAND tente MEM AUT CURRENT DATA SELECT MEH DATA Lv 90 30 OR MEASURE x 0 4210 y 0 4128 NEXT ENTER SFT e 1625 1 11 Press ENTER key Calibration entry screen appears 12 Enter value for calibration 13 14 15 16 key 9 in ascending order decimal point and space available If kept pressed value continuously changes
25. using a calibration channel NEXT ENTER other than CHOO are selected Because of this when existing data measured Je using a calibration channel other than CHOO are selected for performing user Calibration user calibration cannot be performed properly lt SPD gt AUTO 9 lt SYNC gt NO SYNC i i 2 lt LENS gt STANDARD Press COLOR key in SHIFT mode dimi ONUN and select color space MEMORY DATA gt M002 Select same color space as calibration value SELECT MEH DATA Ly 100 76 OR MEASURE to be entered in procedures from 11 to 13 NEXT ENTER cae 10 Press ENTER key z SYNC Calibration entry screen appears Ael ARD Lv 100 76 SET CAL VALUE x 0 3945 OK ENTER REER y 0 3998 68 11 12 13 14 15 Enter value for calibration key 9 in ascending order decimal point and space available If kept pressed value continuously changes 9 key 9 to 0 descending order K M decimal point and space available If kept pressed value continuously changes and M show x10 and x10 respectively See p 71 for details on Numerical value entry ranges Press key to move cursor to second digit position Repeat procedures from 10 to 11 as necessary to enter calibration values for Lv x and y respectively Press ESC key to stop Press ENTER key Afte PLEASE WAIT appears CH SETTING screen appears Wherf PLEASE WAIT appears
26. 00 lt DEFAULT gt lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM MEMORY DATA Mele NO DATA lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt METO NO DATA 9olv lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M lele NO DATA YL lt MODE gt SINGLE le 2 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt lt MODE gt SINGLE e 2 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM MEMORY DATA Mee NO DATA me lt MODE gt SINGLE le 2 1 Y is displayed instead of Lv when observer abgle is 10 2 Not displayed when observer angle is 10 9 Even if either the measured value target color or both are the complementary wave length the difference between the two values will be displayed Further even in such case the display indication will remain Add 36 X VoY YZ CH00 lt DEFAULT gt lt MODE gt SINGLE lie 2 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt Mlele NO DATA 2 Operation Procedure 3 MEMORY MEAS SPEED A
27. 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM MEMORY DATA MEIO DATA A lt ANGL gt 1 VIEW SPD AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM MEMORY DATA M SI9 9 NO DATA pem Displayed and output in tristimulus values X Y Z Displayed and output in dominant wavelength Ad 1 Y is displayed instead of Lv when observer angle is 10 2 Not displayed when observer angle is 10 3 For non spectral colors the complementary wavelength will be displayed However the display indication will remain Ad 34 Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT Y KEY LOCK MENU ESC 2 3 1 Press ESC key when menu or target CH00 lt DEFAULT gt lt ANGL gt 1 VIEW value setting menu appears Measurement screen appears on LCD screen lt MEMORY DATA gt 8 8 DATA Press SHIFT to switch to SHIFT mode SFT appears on bottom left of measurement screen Or make sure that SFT appears on left bottom indicating that this instrument has been operated in SHIFT mode Press COLOR key to select color space CH00 lt DEFAULT gt TMEN i i lt SYNC gt 200 00Hz Measurement screen switches in order of CENE ED Lyxy Lyu v gt LyTAuv gt XYZ Ad Lyxy u lt MEM gt AUTO NUM in SHIFT mode while COLOR key is pressed DATA It switches in order of Yxy Yu v XYZ TER MODE Ad Yxy wh
28. 0Hz cd m lt LENS gt STANDARD CH01 lt DEFAULT gt lt MEM gt AUTO NUM lt MEMORY DATA gt 8 8 DATA Lv lt MENU gt 1 4 CH SETTING MEAS MODE SYNC MODE DELETE e SINGLE BREAK ESC 2 CH SETTING CHO1 lt DEFAULT gt USER CA CH ID NAME CH COPY CH RESET BREAK ESC le 2 CH SETTING CHO1 lt DEFAULT gt USER CAL CH ID NAME CH COPY CH RESET BREAK ESC le 2 lt CH ID NAME gt CH01 lt DEFAULT gt DEFAULT a ENTER E23 fa 2 9 Press key to move cursor lt CH ID NAME gt to second digit position CHO1 lt DEFAULT gt SDEFAULT A 10 Repeat procedures from lt CH ID NAME gt 8 to 9 as necessary CHO1 lt DEFAULT gt SAMPLE Press ESC key to stop 38 11 Press ENTER key cus E PLEASE WAIT appears and it is reset CH SETTING gt screen appears CH ID gt Wher PLEASE WAIT appears do not CH COPY switch OFF Doing so may break stored data CH RESET i 12 Press ESC key two times to return CGD VIEW lt SPD gt AUTO to measurement screen SYNC 60 00Hz cd m L ENS STANDARD MEM AUTO NUM lt MODE gt SINGLE e 21 76 Entering Character If you press SHIFT key to switch to SHIFT mode and then CHAR MODD key when screen to enter calibration channel
29. 4130 CURRENT DATA Lv 90 30 SET CAL VALUE x 0 4210 OK ENTER y 0 4128 SFT e 2 lt CH SETTING gt USER CALI CH ID NAME CH COPY CH RESET BREAK ESC SFT e 2 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC cd m LENS STANDARD MEM AUTO NUM MEMORY DATA M000 NO DATA CHOC DEFAULT lt MODE gt SINGLE SFT lt v o El 5 c o m 2 gt continuation from a p 64 65 MEMORY MEAS SPEED ABS DIFF BACKLIGHT 1 9 9 15 10 14 7 8 11 2 Through selection from saved data 7 Press either key to select lt CH SETTING gt USER CAL and then ENTER key CHOL lt DEFAULT gt USER CA lt USER CAL screen appears CH ID NAME CH COPY CH RESET BREAK ESC e 2 8 9 key USER DATA gt ANGL 1 VIEW CHO1 DEFAULT lt SPD gt AUTO to select stored data lt SYNC gt NO ND lt LENS gt STAND Please select data which was measured using ______ f A KONICA MINOLTA SENSING s calibration standard The data are considered to have been calculated using KONICA SELECT MEH DATA MINOLTA SENSING s calibration standard without compensation coef OR MEASURE ficients for user calibration even if data measured
30. A Lv Buas g 9 lt E 0 1 AAILOAraO Selecting Lens Type Use optional accessory close up lens for small area measurement See instruction manual for close up lens for the placement of one If close up lens is to use measurement value is required for calibration of lens transmission factor Since calibration value varies depending on lens type lens type has to be set in this instrument in advance Erroneous setting causes incorrect measurement Below table shows lens to set and setting for this instrument Arbitrary lens like optional accessory ND Lens to Set No lens P pd ae dd filter 1 10 CS A6 ND Filter 1 100 CS A7 9 9 Combination of close up lens and ND filter Setting at the shipment from factory STANDARD Use standard accessory data management software CS S10w Standard or optional CS S10w Professional to avail more lens type like USER1 USER2 and USERS and register calibration value for lens other than close up lens No 107 and No 122 set in USER1 USER2 or USERS See instruction manual for data management software for details Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT v KEY LOCK n n ESC 2 3 1 7 6 1 Press ESC key when menu or target CH00 lt DEFAULT gt E T n value setting menu appears Lv 20 80 SYNC 200 00Hz cd m lt LENS gt STANDARD Measurement screen appears on LCD screen X 0 4476 lt EM gt AUTO NUM
31. BS DIFF BACKLIGHT v KEY LOCK C al ESC 2 1 Press ESC key when menu or target value setting menu appears Measurement screen appears on LCD screen Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode Press ABS DIFF key to show absolute value ABS or color difference DIFF to select Measurement value switches between that for absolute value ABS and difference while pressing key Setting remains even after switching OFF 37 CH00 lt DEFAULT gt lt ANGL gt 1 VIEW lt MEMORY DATA gt 8 8 DATA CH00 lt DEFAULT gt lt ANGL gt 1 VIEW lt MODE gt SINGLE Je 2 lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD MEMORY DATA M sIe e NO DATA EE PDumes Selecting Digit for Chromaticity Displa This is selectable either 4 or 3 If measurement value on LCD screen is illegible because of blinking set for 3 digits Setting at the shipment from factory 4 FIGURES Operation Procedure MEMORY MEAS SPEED ABS DIFF KEY LOCK m a z 9 E Es o AV IdSIa 2 3 1 7 6 1 Press ESC key when menu or target value setting menu appears Lv 20 80 SYNC 200 00Hz cd m LENS STANDARD Measurement screen appears on LCD screen X 0 4476
32. CHROMA METER 5 200 Instruction Manual KONICA MINOLTA Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as a result of incorrect use of the instrument Denotes a sentence regarding a safety warning or note Read the sentence carefully to ensure safe and correct use Denotes a prohibited operation The operation must never been performed Denotes an instruction The instruction must be strictly adhered to Denotes an instruction Disconnect the AC adapter from the AC outlet Denotes a prohibited operation Never disassemble the instrument OA SOE Notes on This Manual Copying or reproduction of all or any part of the contents of this manual without KON ICA MINOLTA SENCING s permission is strictly prohibited e The contents of this manual are subject to change without prior notice e Every effort has been made in the preparation of this manual to ensure the accuracy of its contents However should you have any questions or find any errors please contact the nearest KONICA MINOLTA SENCING authorized service facility e KONICA MINOLTA SENCING will not accept any responsibility for consequences aris ing from the use of the instrument Safety Precautions To ensure correct use of this instrument read the following points carefully and adhere to them After you have read this manual keep it in a safe place where it can be referred to anytime a question arises Fa
33. D Measurement screen appears on LCD screen 0 4476 vEM AUTONUM 2 Make sure that appears on left bottom indicating this instrument is has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 3 Press MENU key twice lt MENU gt 2 4 Menu 2 4 screen appears on LCD screen STANDARD DISPLAY DIGITS 4 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON BREAK ESC le 2 4 Press either Q or key to select lt MENU gt 2 4 MEMORY MODE and then ENTER key OBJECTIVE LENS STANDARD Inversion cursor moves from DISPLAY DIGITS 4 FIGURES MEMORY MODE to right to change MEMORY MODE AUTO NUM update method of memory channel DATA PROTECT ON BREAK ESC 19 2 50 D Press either Q or key lt MENU gt 2 4 to switch update method of OBJECTIVE LENS STANDARD measurement value directory DISPLAY DIGITS 4 FIGURES If key is pressed mode switches in order of AUTO MEMORY MODE AUTO NUM NUM AUTOSAVE MAN NUM AUTO DATA PROTECT ON NUM If kept pressed this switches continuously In case of 9 key mode switches in reversing order Keep pressing to switch continuously BREAK ESC 2 Buas lt With AUTO setting memory channel number is replaced automatically after storing data by pressing MEMORY key For example if M005 is displayed mea
34. ESC le 2 58 Press either Q or to select DATE amp TIME and then ENTER key lt DATE amp TIME gt screen appears Press either Q or to set arbitrary value Q key for larger number If kept pressed value continuously increases key for smaller number If kept pressed value continuously becomes small Press e key to move cursor to second digit position Cursor shall not move if unsettable number has been entered Repeat the procedures from 5 to 6 as necessary Year range available to set is 2000 to 2099 If you enter month and day that do not exist in calendar error occurs Time range available to set is 00 00 00 to 23 59 59 If you enter incorrect time error occurs Press ESC key to stop Press ENTER key Menu 3 4 screen appears on LCD screen indicating internal clock has been set Press ESC key to return to measurement screen 59 e MENU SLEEP MODE DATE amp TIME BUZZER VERSION BREAK ESC o DATE amp TIME 2005Y 01M O1D 00 00 00 e BREAK ESC 2 lt DATE amp TIME gt 2005 Y 01M O1D 00 00 00 e BREAK ESC 2 lt DATE amp TIME gt 2005Y 02M 01D 15 52 00 e BREAK ESC 2 DATE amp BUZZER lt MENU gt 3 4 SLEEP MODE TIME VERSION BREAK ESC 2 e OFF CH00 lt DEFAULT gt lt ANGL gt 1 VIEW Lv 20 80 X 0 448 SPD AUTO SYNC 200 00
35. Hz cd m LENS STANDARD y 0 448 lt MODE gt SINGLE Je 2 lt MEM gt AUTO NUM lt MEMORY DATA gt 8 8 DATA Lv Buas lt m 2 60 Measurement Preparation juauioJnseo Calibration Calibration Channel There are 21 calibration channels from CHOO to CH20 Following settings are available for all channels 1 Correction coefficient of user calibration 2 Target color 3 CH ID name These are commonly used among each measurement mode of Lyxy Lyu v LyTAuv XYZ and dominant wavelength in one channel is for measurement based upon KONICA MINOLTA SENSING s calibration stan dard Its calibration correction coefficient has been set and is unchangeable Only target color and CH ID name settings are available To switch calibration channel press either or key in SHIFT mode to switch one ap pearing on LCD screen CH ID name can be given to each channel through key operation CH ID name is shown on LCD screen together with calibration channel 62 User Calibration User calibration indicates to set user s original correction coefficients in calibration chan nel by setting calibration value For Ly x and y or Ly u and v or X Y and Z in this in strument Displayed and output values for every measurement are values corrected with this cor rection coefficient unexceptionally Following calibration is availab
36. ID and measurement value ID of stored data in appears available character type for entry shifts in order of Capital Alphabet Small Alphabet Numerical Symbol Capital Alphabet Either A a 1 or s appears on the right of character entry area depending on character type Characters available to enter Mark Capital Alphabet A to Z Space Small Alphabet fa 2 z Space Numerical to 9 Symbol Space 4 96 amp lt gt Q 1 juauioJnseo Setting and Changing Target Color Target color Target color serves as reference for measurement of deviation of measured color from reference It can be set channel by channel Setting methods are as follows 1 2 User calibration Calibration value is simultaneously set as target color in user calibration Measurement Select from stored data Enter numerical value 3 4 lt wa Previously set target color is to erase since target color setting is performed at the same time as entry of user calibration correction coefficient Previously set target color should be replaced with and changed to another one to change User calibration correction coefficient shall not be influenced despite of target color change Target color is commonly used among each measurement mode of Lv
37. MENU key lt MENU gt 1 4 Menu 1 4 screen appears on LCD screen CH SETTING MEAS MODE SINGLE SYNC MODE DELETE me 2 BREAK ESC 42 Press either Q or key to select MEAS MODE and then ENTER key Inversion cursor moves from MEAS MODE to right to change measurement mode Press either Q or key to set for SINGLE or CONT Press ESC key to stop Press either ENTER key Inversion cursor returns to MEAS MODE Now change has been set Press ESC key to return to measurement screen Measurement is made only once when user calibration and target color measurement are done even though CONT has been set In case of measuring max and min values continuous measurement is made even though SINGLE has been set Setting remains even after switching OFF O 43 CHS lt MENU gt 1 4 ETTING MEAS MODE SYNC MODE DELETE e 1e e BREAK INGLE ESC lt MENU gt 1 4 CH SETTING MEAS MODE SYNC MODE DELETE BREAK 2 ESC lt MENU gt 1 4 CH SETTING SYNC MODE DELETE CONT BREAK ESC 2 2 cd m x 0 3855 y 0 4447 lt MODE gt Je CHO0 lt DEFAULT gt lt ANGL gt 1 VIEW Lv 0 45 lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD MEM AUTO NUM lt MEMORY DATA gt Lv 0 54 x 0 4004 y 0 4123 Buas lt EAE Selecting of Max or Minimum
38. MODE gt SINGLE SFT e 2 64 4 Press SHIFT key to cancel SHIFT mode CHO01 lt DEFAULT gt lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC cd m lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt 000 NO DATA D Press MENU key MENU 1 4 Menu 1 4 screen appears on LCD screen CH SETTING MEAS MODE SINGLE SYNC MODE DELETE BREAK ESC le 2 6 Press either Q or key to select lt CH SETTING gt CH01 lt DEFAULT gt USER CAL and then ENTER key USER CA lt USER CAL gt screen appears CH ID NAME CH COPY CH RESET BREAK ESC Je I7 Continues to the following page 1 Through measurement p 66 to 67 2 Through selection from saved data p 68 to 69 3 Copy from other calibration channel p 70 to 71 65 INNER uoneiedoud Ia Fe M volesedaig continuation from p 64 65 MEMORY MEAS SPEED I ABS DIFF BACKLIGHT KEY LOCK ESC 9 9 16 11 15 7 12 1 Through measurement 10 Press either Q or key to select USER CAL and then ENTER key lt USER CAL DATA gt screen appears Use close up lens select measuring angle adjust finder diopter and focus For more details on each operation see p 88 Use light source of which luminance and chromaticity are known on object Press COLOR key in SHIFT mode and select color space Select
39. Make sure that object around aperture looks clear when observing object through finder Only measuring area for measuring object must be placed in aperture If extra area which is not measuring object is included in aperture you cannot perform correct measurement 88 5 6 Press ESC key when menu or target value setting menu appears Measurement screen appears on LCD screen Press measurement button Securely support this instrument so that measuring object should not be removed from aperture when pressing measurement button Ly value appears in finder Ly value Y value when observer angle is 10 appears in any color space setting for LCD screen Measurement result appears on LCD screen After measurement do not switch OFF until measurement value appears Doing so may break stored data To stop measurement in continuous press measurement button or arbitrary key on LCD screen When long measurement time is set in single measurement press measurement button or any option key before measurement is completed to stop measurement In case calibration channel is to specify for measurement keep following procedure to select calibration channel before measurement Press either or 9 key to switch calibration channel if measurement screen has been operated in SHIFT mode Calibration channel can be changed after measurement in the same way but recalculation is needed for measurement value after meas
40. NDARD return to measurement screen X Eon TORUM MEMORY DATA M000 NO DATA lt MODE gt SINGLE SFT e 2 29 2 ao 8 o m 2 O gt im Numerical value entry ranges e Numerical value entry ranges are shown below aggeRcacpatas iti isfi CHWE DEFAULT lt SPD gt AUTO e All conditions should be satisfied A 2 LENS STANDARD 0 lt x lt 1 and X MEM AUTO NUM 0 lt y lt 1 and CURRENT DATA Lv 90 30 0 lt x y 1 and SET CAL VALUE x 0 4210 0 lt X 99999000000 and 0 lt Y 99999000000 and 0 7 s 99999000000 Characters following K and M are ignored 1 0 is interpreted as 1 0K i e 1000 Characters following second decimal point are ignored 1 2 3 is interpreted as 1 2 Characters following space between numbers are ignored 1 2_3 is interpreted as 12 71 A v o o 5 3 at 2 o m Reset User Calibration User calibration can be reset channel by channel KONICA MINOLTA SENSING s calibra tion is to apply to channel for which user calibration has been reset Also target color and ID name settings in the channel are to delete Operation Procedure MEMORY KEY LOCK MEAS SPEED ABS DIFF BACKLIGHT ESC ENTER 2 4 5 1 10 6 78 Press ESC key when menu or target value setting menu appears Measurement screen appears on LCD screen Pres
41. OW gt MANUAL AUTO if pressed when screen with which measurement is available p 28 Selects whether chromaticity is displayed in absolute value ABS or difference DIFF if pressed when measurement screen appears p 36 Selects backlight ON OFF on LCD screen p 54 Switches between valid invalid for acceptance of each key operation after being kept pressed for at least 2 seconds ap proximately Menu screen appears if pressed when measurement or save Screen appears In case of menu screen screen switches in or der of menu 1 4 menu 2 4 menu 3 4 menu 4 4 menu 1 4 To return to measurement screen if pressed when menu or target value setting screen appears If pressed when entering numerical value or making various settings setting is stopped To enter numerical value with or fix settings 14 SHIFT mode Press SHIFT key to switch between SHIFT mode and normal mode In SHIFT mode keys from to Q and become valid in normal mode keys from D to and become valid Keys of 9 D are always valid either in SHIFT mode or normal mode O TARGET e COLOR PEAK VALLEY OSHUTTER OSHIFT CHAR MODE ORECALC Gkey Okey key Okey To go to target value setting screen from either measurement or save screen If pressed when screen with which measurement is available color space is switched in order of Lyxy L u v d uv XYZ dominant wavel
42. S SLOW gt MANU AUTO while this key is pressed MANU Setting Screen to set measurement time from appears Press either Q or key to set value Q key for larger number If kept pressed value continuously increases key for smaller number If kept pressed value continuously becomes small press key to move cursor to second digit position Press either Q or key to set value Selectable measurement time range is 1 to 60 sec Press ESC key to stop Press ENTER key to fix measurement time Measurement time setting remains even after switching OFF 29 cd m lt LENS gt STANDARD lt MODE gt SINGLE Je 2 CH00 lt DEFAULT gt lt ANGL gt me lt 5 gt MANUS Ly SYNC NO SYNC MEM AUTO NUM MEMORY DATA M eIe e NO DATA Lv lt MODE gt SINGLE Je 2 lt MODE gt SINGLE e 2 SSPD d lt 5 gt SYNC cd m lt LENS gt STANDARD lt MODE gt SINGLE Je 2 lt gt AUTO NUM lt MEMORY DATA gt 8 8 DATA Lv Buas n v m m SVAIN Internal Sync Measurement Mode Settin Internal sync measurement mode refers to measurement mode where measurement is made in the same timing as periodical light source pulse frequency such as vertical syn chronization frequency for display Setting at the shipment from factory NO SYNC Operation Procedure S o 2 gt
43. TA SENSING s calibration standard CHOO 2 Through measurement Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT v KEY LOCK MENU ESC 4 2 1 8 7 3 S 5 1 Press ESC key when menu or target CHO1 lt DEFAULT gt lt ANGL gt 1 VIEW value setting menu appears Measurement screen appears on LCD screen lt MEMORY DATA gt 6 6 DATA Lv A v o o 1 Ed gt 2 10 m 2 Press SHIFT key to switch to SHIFT mode SFT appears on left bottom Or make sure that SFT appears on left bottom indicating that this instrument has been operated in SHIFT mode 3 Press either Q or key to switch 4 ee 5 TEY calibration channel and select one lt SYNC gt NO SYNC for which target color is to set Ra Once target color is set calibration TOES channel cannot be returned to previous status before setting Make sure to check lt MODE gt SINGLE channel number before overwriting sri esses 4 Press TARGET key lt ANGL gt 1 VIEW lt SPD gt AUTO lt TARGET gt screen appears SSYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM SELECT MEH DATA OR MEASURE NEXT ENTER SFT 624 80 5 Use close up lens select measuring angle adjust finder diopter and focus For more details on each operation see p 88 Press Measurement button to start measurement Now starts measurement Mea
44. Value Displa Measurement result display is selectable among latest max and minimum If max lt PEAK gt or minimum lt VALLEY gt has been selected here continuous measurement is to perform even though single measurement has been set L determines max and min values Setting at the shipment from factory latest ccm o o Operation Procedure e S lt T F E MEMORY MEAS SPEED ABS DIFF BACKLIGHT yi VKEY LOCK MENU ESC ENTER 2 3 1 1 Press ESC key when menu or target CH00 lt DEFAULT gt E T BY value setting menu appears lt SYNC gt NO SYNC lt LENS gt STANDARD Measurement screen appears on LCD screen lt MEM gt AUTO NUM lt MEMORY DATA gt M003 Lv 0 54 x 0 4004 0 4123 2 Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 44 3 Press PEAK VALLEY key to show measurement mode to select Measurement screen switches in order of normal PEAK VALLEY normal in SHIFT while pressing PEAK VALLEY key Latest measurement value shall appear as result in normal maximum in PEAK and minimum in VALLEY for continuous measurement Latest measurement value also appears on LCD screen in case that PEAK or VALLEY has been selected Setting for normal screen lt PEAK gt lt VALLEY gt shall be
45. Without data management software CS S10w Operation Procedure 108 With data management software CS S10w Outer Dimensions 109 Error Messages 110 Error Check 113 Identifying Version 116 Changing Luminance Unit cd m fL 118 Specification 120 Standard Accessor Lens Cap e Attached to objective lens for protecting it when not using this instrument Holding Cap CS A24 e Prevents measuring angle selector position from deviating during transfer Remove one when using this instrument and store not to lose Do not fail to set measuring angle selector at center 0 2 for transfer before at taching this holding cap to measuring angle selector ND Eyepiece Filter CS A27 e Eases glare when peeping into finder to measure high luminance object Always set this filter on finder when measuring high luminance object AC Adapter AC A23 e Supplies power from AC outlet Input 100 V 120 V or 200 V 240 V 1 0 A 50 60 Hz 30 45 VA Output 5 V 2 8 A Data Management Software CS S10w Standard e Software to control this instrument from PC Q for data management USB Cable 2 m IF A17 e Used for communication between this instrument and PC Optional Accessories Close Up lens No 107 Close Up lens No 122 e Placed before objective lens for measure ment of small
46. adapter input terminal and USB connector Objective lens Directed to object for measurement Focus adjustment ring p 88 Adjusts focus of objective lens before measurement Focus distance scale p 88 Helps adjusting focus LCD screen p 18 Displays various screens like measurement and menu Key panel p 14 Offers several keys for operation of this instrument Measurement button p 88 For measurement Stops measurement when pressed during measurement Finder p 16 88 Used to observe object for measurement Diopter adjustment ring p 17 88 Adjusts diopter Aperture p 16 Indicates measuring area Size of black circle will change depending on measuring angle In finder indicator p 16 L value appears on in finder indicator Hand strap p 21 Used to carry this instrument with hand Screw hole for fixing p 20 Used to fix this instrument with tripod or jig Battery chamber p 25 Used to set the batteries 13 YKEYLOCK 9 2 MEMORY MEAS SPEED ABS DIFF RR OIMENU ESC JENTER Main Functions of Each Key MEMORY MEAS SPEED ABS DIFF BACKLIGHT KEY LOCK MENU ESC amp ENTER Measured data is stored in memory by pressing this key when measurement screen and save screen appears Measurement time is switched in order AUTO LTD AUTO Super FAST FAST SLOW Super SL
47. aking various set tings cursor position is moved 15 Indicator Inside Finder TAperture Ly value appears on in finder indicator 0 2 Aperture K displayed as 4 and M displayed as show x10 and x10 respectively 0 1 Aperture 16 Diopter Adjustment Rotate diopter adjustment ring for adjustment of diopter Diopter adjustment ring Adjust so that A or B on aperture or black circle indicating measuring area looks clear when ob serving object through finder Adjustment would be easy starting with 1 aper ture where object near aperture looks blur Make sure to adjust diopter before measurement Diopter should be adjusted for the eyesight of the person who will be taking measurement If diop ter is not adjusted before focus measurement correct measurement value may not be expect ed This is because the focus is actually off even if you think it is correctly in focus In addition if diopter is not correctly adjusted you may see the aperture moving depending on viewing angle You sometimes see small black dots or stripes in internal finder This happens due to character istics of optical system not dust or dirt in internal finder It gives no effect on measuring perfor mance 17 Ee axe 5 e a LCD Screen Measurement Screen CH ID name p 74 Calibration channel p 62 PEAK is displayed when the mea surement result was obtained at PEAK for Co
48. alue minimum value is MTE NO DATA gt stored in max min value measurement lt MODE gt SINGLE Note that measurement value for every lo dem measurement is stored when AUTONUM is set in max min value measurement If set for AUTO NUM or AUTOSAVE and all memory channels have been used up is to use again to be overwritten In case that stored data already exists in the channel to store in warning message OK TO OVERWRITE appears If OK press ENTER key and if not ESC key This warning message can be set not to appear See p 48 CH01 lt DEFAULT gt Da y MEW OK TO OVERWRITE OK ENTER CANCEL ESC lt MODE gt SINGLE le 2 91 AYOWAW U9U9Jnseo A ET AN women Displaying Stored Data and Setting Measurement Value ID Name Follow below procedures to display stored data Operation Procedure BACKLIGHT MEMORY MEAS SPEED ABS DIFF KEY LOCK Press ESC key when menu or target value setting menu appears Measurement screen appears on LCD screen Make sure that appears on bottom left of measurement screen indicating it has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode Press either Q or key to move to save screen Press either Q or key to switch channel number Number increases in descending order If kept pressed number continuo
49. ars on LCD screen Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode Press MENU key four times Menu 4 4 screen appears on LCD screen Press ENTER key Inversion cursor moves from OBSERVER to right to change observer angle 32 CHO00 lt DEFAULT gt lt ANGL gt 1 VIEW Lv 20 80 lt SPD gt AUTO SSYNC gt 200 00Hz cd m LENS STANDARD x 0 4476 MEM AUTO NUM y 0 4477 MEMORY DATA Maoa NO DATA Lv lt MENU gt 4 4 OBSERVER 2 OBS le BREAK ESC 2 lt MENU gt 4 4 OBSERVER 2 OBS Ne BREAK ESC 2 9 Press either Q or key to set lt MENU gt 4 4 either for 2 OBS or 10 OBS OBSERVER 10 OBS Press ESC key to stop BREAK ESC o me Press ENTER key MENU 4 4 PLEASE WAIT appears OBSERVER 10 OBS inversion cursor moves from OBSERVER to right to change observer angle Wherf PLEASE WAIT appears do not BREAK ESC switch OFF Doing so may break stored data 10 Press ESC key to return to CHOO DEFAULT lt ANGL gt 1 VIEW lt SPD gt AUTO measurement screen lt 5 gt 200 00Hz WT cd m LENS STANDARD Setting remains even after switching OFF O MEM AUTO NUM MEMORY DATA METO NO DATA When o
50. auoJnseajJ Measurement Operation Procedure 1 Decide whether you use close up lens optional or not according to measuring object size and distance See the table below for details on measuring distance and measuring area If you set close up lens lens type setting is required in this instrument See p 40 distance and measuring area unit mm Taman feeder eels olor fmol so fos eefe me mo ptem 22 as froles we apte oeloes e 1 1 1 1 1 Measuring distance is the distance from the front edge of the metal lens barrel or close up lens ring 2 Slide measuring angle selector according to size of object and select either aperture1 0 2 or 0 1 The measuring angle select is covered with holding cap CS A24 see p 8 at shipment from factory Pressing with finger cushion slide measuring angle selector slowly Do not operate measuring angle selector during measurement If measuring angle is switched during measurement you may fail to perform measurement or to obtain correct measurement value 3 Rotate diopter adjustment ring on finder for diopter adjustment Make sure that aperture black circle indicating measurement area looks clear when observing object through finder See p 17 4 Rotate focus adjustment ring for objective lens for that purpose
51. bserver angle is set to 10 Lv display EN changes to Y display Lv and Y display in stored data is retained after changing observer angle 33 Dunes Gunies Selecting Color Space See below table for available color space Setting at the shipment from factory Lyxy Color space LCD Screen Display Description Luv 1 CH00 lt DEFAULT gt lt MODE gt SINGLE Jo 2 CH00 lt DEFAULT gt lt MODE gt SINGLE e 2 CH00 lt DEFAULT gt lt MODE gt SINGLE e 2 lt ANGL gt 1 VIEW SPD AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM MEMORY DATA MEIO NO DATA lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt DATA Ly lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt MOa DATA Lv Tisma AUV Displayed and output in luminance Ly and chro maticity coordinates x y Displayed and output in luminance Ly and u v chromaticity diagram CIE 1976 UCS chromaticity diagram coordinates u v Displayed and output in luminance L correlated color temperature T and color difference from blackbody locus Auv CH00 lt DEFAULT gt lt MODE gt SINGLE me 2 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200
52. ce Filter AC A27 a ND Filter L 1 10 CS A6 p 1 100 CS A7 Close Up Lenses AC Adapter No 107 AC A23 No 122 Data Management Software CS S10w Professional Holding Cap CS A24 Used during shipment CN roe el USB cable 2m IF A17 PC commercially available White Calibration Plate For 45 0 aa O White Calibration Plate For d 0 CS A21 Data Management Software White Calibration Plate Set Standard CS A22 including CS A20 and CS A21 aT Soft Case CS A23 11 Names and Functions of Parts Names of Each Part LCD screen Focus distance scale Objective lens Power switch teri i Focus adjustment ring C adapter input terminal Measuring angle selector USB connector Protect cover Finder Measurement button Diopter adjustment ring Hand strap Inside Finder Screw hole for fixing Aperture battery chamber cover in finder indicator Functions of Each Part Power switch 23 Switches this instrument on off I for ON for OFF AC adapter input terminal p 23 To which accessory AC adapter is connected USB connector p 98 To which USB cable is connected when used with PC Measuring angle selector p 88 Used to select measuring angle among 1 0 2 and 0 1 Protect cover p 23 98 Protects AC
53. change in ambient temperature which may form dew condensation Avoid using this instrument in extremely dusty or humid place Use this instrument at ambient temperature between 0 and 40 C and relative humidity 8596 or less at 35 C with no condensation Operating this instrument outside speci fied temperature and humidity range may unsatisfy its original performance 3 This Instrument Do not subject this instrument to strong impact or vibration Do not forcibly pull bend or apply strong force to power cord for attached AC adapt er or USB cable This may result in snapping Connect this unit to power source with minimal noise e Should breakage or abnormality be found during operation switch power off immedi ately and unplug Then refer to Error Check on page 111 e Should this instrument break down do not try to disassemble and repair it by your self Please contact the nearest KONICA MINOLTA SENSING authorized service facil ity e Warm this instrument up for 15 minutes at least after switching power on when the luminance is 10 cd m or lower measuring angle 1 This helps to improve the mea suring accuracy Backup Battery e Measurement data and settings are stored in memory which is backed up by internal backup battery Backup battery is charged during operation of this instrument and can retain memory content for 3 months if it has been fully charged At the time of purchasing battery may have already been
54. d color temperature T and color difference from blackbody locus uv Color temperature refers to the temperature of black body perfect radiator which has equal chromaticity coordinates to certain light However color temperature only repre sents colors on blackbody locus Correlated color temperature slightly wider interpretation of color temperature is very useful to eliminate such problem Here correlated color temperature covers those which are slightly outside the range of that of blackbody locus If a certain color positions on isotemperature line the intersection point of isotempera ture line and blackbody locus is indicated as correlated color temperature for the color Isotemperature line means line on chromaticity coordinates which is a set of colors visu ally close to color temperature on blackbogy locus However since all colors on a color matching temperature line are represented with equal correlated color temperature it is not possible to describe color only with corre lated color temperature To solve that Auv deviation of correlated color temperature T from blackbody locus is to apply for that purpose If Auv exists above blackbody locus it is represented with and below with 0 20 0 25 0 30 V Blackbody locus ee 0 35 perse Correlated temperature T E 0 30 Sa o o o 3 u Correlated temperature T and Auv 103 uold
55. do not switch OFF Doing so may break stored data Press ESC key twice to return to measurement screen 69 USER CAL DATA CH01 DEFAULT SET CAL VALUE OK ENTER SFT e 201 lt USER CAL DATA gt CH01 lt DEFAULT gt SET CAL VALUE OK ENTER SFT e 2 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M002 Lv 100 76 x 0 3945 y 0 3998 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M002 Lv 100 76 x 0 3945 y 0 3998 lt lt USER CAL DATA gt CH01 lt DEFAULT gt Lv 1007 0 3945 y 0 4000 SET CAL VALUE OK ENTER SFT 2 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M002 Lv 100 76 x 0 3945 y 0 3998 lt CH SETTING gt CHOH lt DEFAULT gt USER CH ID NAME CH COPY CH RESET BREAK ESC SFT e 2 lt gt lt MODE gt SINGLE SFTle 2 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M002 Lv 100 76 x 0 3945 y 0 3998 LOR Uoleedaig jueuieJnseo u continuation from a p 64 65 MEMORY MEAS SPEED ABS DIFF BACKLIGHT V KEY LOCK
56. easurement screen Setting remains even after switching OFF O 41 MENU 2 4 No 107 DISPLAY DIGITS 4 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON Ser ESC CH00 lt DEFAULT gt lt ANGL gt 1 VIEW lt SPD gt AUTO Lv 20 80 sS Ne gt 200a cd m x 0 448 VIEM gt AUTO NY y 0448 Lv lt MODE gt SINGLE le 2 Buas z 9 0 Dunes EXE Selecting Single or Continuous Measurement Here measurement mode is selectable between Single measurement and Continuous measurement Former means one measurement for one press and the latter continuous measurement from one press to another press of any key In case of Continuous mea surement you can also view max and min values during continuous measurement when measurement is completed Setting at the shipment from factory SINGLE Operation Procedure MEMORY MEAS SPEED ABS DIFF KEY LOCK 1 Press ESC key when menu or target CH00 lt DEFAULT gt ES Es value setting menu appears i lt SYNC gt NO SYNC lt LENS gt STANDARD Measurement screen appears on LCD screen lt MEM gt AUTO NUM lt MEMORY DATA gt M003 Lv 0 54 x 0 4004 y 0 4123 2 Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 3 Press
57. en appears on LCD screen Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode Press MENU key twice Menu 2 4 screen appears on LCD screen Press either Q or key to select DATA PROTECT and then ENTER key Inversion cursor moves from DATA PROTECT to right to change setting for data protection 48 4 5 CH00 lt DEFAULT gt lt ANGL gt 1 VIEW lt SPD gt AUTO Lv 20 80 lt SYNC gt 200 00Hz cd m lt LENS gt STANDARD X 0 4476 lt em gt auTo NUM MEMORY DATA y 0 4477 8 8 DATA lt MENU gt 2 4 STANDARD DISPLAY DIGITS FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON BREAK ESC le 2 lt MENU gt 2 4 OBJECTIVE LENS STANDARD DISPLAY DIGITS 4 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON BREAK ESC le 2 5 Press either Q or key to set for ON or OFF If ON has been selected a warning message OK TO OVERWRITE appears when trying to store data to the directory with existing data i lt ANGL 1 VIEW CH02 lt DEFAULT gt EU AUTO OK TO OVERWRITE ENTER OK CANCEL ESC y 0 3863 OFF proceeds with overwriting without warning message Press ENTER key Inversion cursor returns to DATA PROTECT to fix setting for data protection Press ESC key to r
58. en observer angle is 10 Color space setting remains even after switching OFF O 35 lene Dunes Dunes Selecting Absolute Value ABS Difference DIFF Displa Whether chromaticity value is shown in absolute ABS or difference DIFF is selectable See below table for each case Setting at the shipment from factory Absolute value ABS Color Space Switching between Absolute Value ABS and Difference DIFF Dominant wavelength 1 CH00 lt DEFAULT gt lt gt 1 VIEW lt SPD gt AUTO SSYNC gt 200 00Hz cd m lt LENS gt STANDARD X lt IMEM gt AUTO NUM MEMORY DATA MEIO NO DATA Lv A D um Y lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt Maa DATA Ly lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt 8 8 DATA Ly 8 lt MODE gt SINGLE Nee lt ANGL gt 1 VIEW SPD AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM MEMORY DATA MaJo NO DATA lt MODE gt SINGLE NIIS e 2 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt IMEM gt AUTO NUM MEMORY DATA MEIO DATA Ad lt MODE gt SINGLE e 2 VoL ALy Ax Ay CH
59. ength L xy p 35 Switched to either of normal measurement PEAK Max value appears for continuous measurement or VALLEY Minimum value appears for continuous measurement screen if pressed when measurement screen appears p 44 Selects whether finder shutter automatically closes for each measurement or always opens if pressed when screen with which measure is available To close automatically 8 appears on bottom left of screen and O to always keep opened p 48 Selects either SHIF1 mode Normal mode For SHIFT mode SFT appears on bottom left of screen and keys from to O and become valid In case of normal mode appears on bottom left of screen and keys from D to and amp become valid If pressed when screen where ID is to input character type to enter switches in order of Capital Alphabet Sm all Alphabet Numerical Value Symbol Capital Alphabet p 77 Pressed when calibration channel is changed for measure ment value on measurement screen Measurement value is recalculated p 89 If pressed when measurement or save screen appears calibra tion channel is changed in SHIFT mode memory channel is changed in normal mode If pressed when entering numerical value or making various set tings numerical value or setting is changed If pressed when measurement or save screen appears the screen switches between measurement and save screen If pressed when entering numerical value or m
60. ess unfunc Press correct key tional key Hasn t it been KEY Press KEY LOCK key 14 LOCK for approx 2 or more seconds to release KEY LOCK 4 Measurement unavail Doesn t menu screen Conduct measure 18 able even after pressing appear ment with measurement measurement button screen appearing 5 Gap between entered Calculation error could 116 113 uonduoseq uonduoseg Error Page to Symptom Item to Check Corrective Action No Refer 6 Measure Does data exist This appears when there is no data ment value in measurement value stored data appears as calibration value and target color ORA z Doesn t color space This appears when color tempera 34 become color tempera ture cannot be converted for display ture Available display range is as follows 2300STS20000 K lA uvI 0 1 Doesn t measurement This appears when luminance value value become larger by exceeds the available display area in user calibration this instrument Do you set target color This appears in color difference dis 78 for color difference play when target color is not set measurement 7 Measurement Is object to measure Keep object to measure stable values vary stable Isn t object to measure Repeatability of x y worsens if ob 4 of low luminance ject of low luminance is measured 28 It becomes worse especially when measurement angle is 0 2 or 0 1 Also it beco
61. essed character switches continuously Z to A in ascending order and space If kept pressed character switches continuously Small alphabet numerical value and symbols are also available See p 77 for details Press e key to move cursor to second digit position Repeat procedure from 6 to 7 as necessary Press ENTER key to return to save screen to show entered Measurement value ID Name 93 lt ID NAME gt M006 8 Lv 50 02 0 3369 0 3256 le 2 ID NAME gt M006 S 1 lv 50 02 x 0 3369 y 0 3256 OK ENTER le 2 ID NAME gt M006 SAMPLE Lv 50 02 x 0 3369 y 0 3256 OK ENTER 18 2 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt HOLD DATA gt Lv 50 02 x 0 3473 y 0 3504 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt HOLD DATA gt Lv 50 02 x 0 3473 y 0 3504 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt HOLD DATA gt Lv 50 02 x 0 3473 y 0 3504 SAMPLE CH02 lt DEFAULT gt Lv 50 02 em x 0 3369 y 0 3256 ID NAME ENTER le 2 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt HOLD DATA gt lv 50 02 x 0 3473 y 0 3504 ETN AN 7 Del
62. et color measuring mode for object color with CS S10w 4 Conduct white calibration with CS S10w Measurement of Object 5 Set object on the same position and at the same angle as white calibration plate 6 Now measurement can be done with CS S10w See instruction manual of data management software CS S10w for details uoidioseq 108 Outer Dimensions Unit mm 10 5 95 Filter thread le diameter 240 5 noo rim 9 o Standard plane for distance measurements For tripod screw 154 depth 6 5 2 y Optical axis 4 Au C 7 For M5 screw i l For M5 screw depth 6 5 ds depth 6 5 616 T0 150 eo eo 109 uoldiuoseg Error Messages Error message appears on LCD screen for incorrect operation of this instrument through key Below table shows type of error message its description and corrective action respectively Error message Cause Description Corrective Action BATTERY OUT Battery voltage decreases Switch this instrument OFF side and replace with new batter ies or AC adapter DATA SET ERROR Entered numerical value is Enter again Note that measure out o
63. ether or combine different type batteries When installing batteries in instrument make sure that they are correctly oriented according to and marks Failure to any of these may damage battery or liquid leakage resulting in fire injury or air pollution Do not place this instrument on unstable or sloping surface which may drop or overturn it Dropping or overturning may injure someone around Take care not to drop this instrument when carrying it Do not move while looking inside finder since this would fall or injure user Take special care in handling close up lens Breakage of close up lens may injure Someone around ntroduction This chroma meter realizes high precision measurement of luminance and chromaticity comparable to spectroradiometers by the employment of newly developed spectral fit ting method Carefully read this manual before using one Packaging material Retain accompanying packaging materials carton protector and plastic bag and holding cap CS A24 supplied as standard accessory for future usage This is delicate measurement instrument Use packaging materials supplied in pur chasing in case this instrument needs to be transferred for such purpose as main tenance in KONICA MINOLTA SENSING s factories These packaging materials are useful for minimizing shock or vibration to this instrument in such situation Use hold ing cap for the same purpose especially to protect optical system of this in
64. eting Stored Data Follow below procedures to delete stored data Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT KEY LOCK 2 3 1 8 4 6 7 4 5 1 Press ESC key when menu or target CHOO lt DEFAULT gt nO 1 VIEW value setting menu appears lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt MO NO DATA Lv Measurement screen appears on LCD screen 2 Make sure that appears on bottom left of measurement screen indicating E it has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate SHIFT mode a Press SHIFT key to cancel SHIFT mode Press MENU key lt MENU gt 1 4 Menu 1 4 screen appears on LCD screen H SETTING MEAS MODE SINGLE SYNC MODE DELETE BREAK ESC le 2 4 Press either Q or key to lt MENU gt 1 4 select DELETE and then ENTER CH SETTING lt DELETE gt screen appears MEAS MODE SINGLE SYNC MODE DELETE BREAK ESC elke 2 94 5 Press either Q or key to select channel number of which stored data is to delete Press key and move cursor to ALL to delete all stored data not that only for individual channel Press ENTER key Message OK TO DELETE M appears In case of deleting all data message OK TO DELETE ALL DATA appears Press ENTER key NO DATA appears after stored data is deleted Press ENTER key twice to return to mea
65. eturn to measurement screen Setting remains even after switching OFF O 49 lt MENU gt 2 4 OBJECTIVE LENS DISPLAY DIGITS STANDARD 4 FIGURES MEMORY MODE AUTO NUM DATA PROTECT ON BREAK ESC 2 le lt MENU gt 2 4 OBJECTIVE LENS STANDARD DISPLAY DIGITS 4 FIGURES MEMORY MODE AUTO NUM ON BREAK ESC 19 2 CH00 lt DEFAULT gt lt ANGL gt 1 VIEW Lv 20 80 lt SPD gt AUTO ame gt 20 lt LENS gt STANDARD 0 4476 MEM AUTO NUM lt MEMORY DATA gt 8 8 DATA Lv y 0 4477 lt MODE gt SINGLE Je 2 1 viva UU 2 m 9 4 Ele Gumes A EI Setting of Update Method for Memory Channel to Store Measurement Value There are 100 directories to store measurement value from to M100 and each can store one value therefore 101 in total Here whether measurement value is to store automatically or by pressing MEMORY key is selectable for every measurement See p 50 for details on protection of stored data when data storage is to perform on memory channel with another measurement value Setting at the shipment from factory AUTO NUNM Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT KEY LOCK 2 3 1 7 6 1 Press ESC key when menu or target CH00 lt DEFAULT gt ee T EM value setting menu appears Lv 20 80 SYNC 200 00Hz cd m LENS STANDAR
66. f range ment value should completely satisfy the ranges below O x 1 0 lt lt 1 lt 1 0 lt 99999000000 0 lt 99999000000 0 2 99999000000 When is selected e Select channel except CHOO and NOT SETTA calibration channel is go redo the operation BLE BY USER ing to be operated or target color is going to be set INCORRECT Measurement data measured Select measurement data meas OBSERVER with different observer angle ured with channel and observer CONDITION from that for channel is going angle or reset calibration channel to be used for user calibration and redo setting for that channel or for target color setting NO DATA Without measurement data Select data to measure or meas user calibration is going urement data and redo setting to be performed or target color to be set UNDER Luminance of measuring e Remove lens cap and check if object is lower than avail luminance of measuring object able measurement range is within available measurement range and then redo measure ment Check if user calibration is cor rectly performed and redo meas urement Check if settings for measurement angle observer angle and lens are correct and redo measurement f symptom does not improve please contact the nearest KONI CA MINOLTA SENSING authorized service facility 110 Error message Cause Description Corrective Action
67. get CH00 lt DEFAULT gt T M value setting menu appears Lv 20 80 sYNc 200 00Hz cd m LENS STANDARD Measurement screen appears on LCD screen X 0 4476 lt em gt AUTO NUM MEMORY DATA y 04477 8 8 DATA Lv 2 Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 3 Press BACKLIGHT key If backlight has been on it is switched off and off switched on Setting remains even after switching OFF 54 Setting 5 LIGHT 55 Setting Sleep Mode Sleep mode can be set for saving electric power consumption for the case that key has not been operated or communication has not been done for more than 30 minutes Setting at the shipment from factory OFF Operation Procedure S o 2 gt MEMORY MEAS SPEED ABS DIFF BACKLIGHT zo YKEY LOCK my ESC 2 3 1 7 4 6 5 1 Press ESC key when menu or target CH00 lt DEFAULT gt T EM value setting menu appears Lv 20 80 sYNc 200 00Hz cd m LENS STANDARD Measurement screen appears on LCD screen X 0 4476 lt MEM gt AUTO NUM MEMORY DATA y 04477 8 8 DATA Lv 2 Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is t
68. i has changed greatly from the pre nance has changed vious measurement is measured greatly from the measurement may be interrupted to previous measure set the optimum gain for measure ment ment and then remeasurement will be performed during remeasure ment the remaining measurement time display is frozen 10 PC cannot Has USB cable been Connect this instrument and PC 98 read output tightly connected securely data from this Med Hasn t remote mode Switch to remote mode by sending 99 nected with Peen cancelled connection command from PC to this USB Com instrument mand or data Use standard accessory data manage cannot be ment software CS S10w Standard entered from Has prepared program Check referring to sample program Use PC to this been correct standard accessory data management instrument software CS S10w Standard 11 Measurement Hasn t backup battery Switch ON to charge backup battery 4 data or vari been insufficient after Backup battery is to fulfill its func ous setting long time period of tion after fully charged for approx 20 becomes nonuse Has backup hours invalid soon battery been charged Shelf life of backup battery is 10 enough at the time of years under general use but re purchased placement is needed should memo ry disappears soon after full charge For replacing backup battery please contact the nearest KONICA MI NOLTA SENSING authorized service facility 12 Same
69. ilure to adhere to the following points may result in death or serious injury Do not use this instrument in places where flammable or combustible gases gasoline etc are present Doing so may cause fire Always use the AC adapter and power cord supplied as a standard accessory or optional AC A23 and connect it to indoor AC outlet of rated voltage and fre quency Failure to follow either of these may result in damage to unit fire or electric shock If this instrument is not used for a long time disconnect AC adapter from AC outlet Accumulated dirt or water on prongs of AC adapter plug may cause fire and should be removed Do not forcibly pull any part on power cord when unplugging since this may damage power cord resulting in fire or electric shock Gently disconnect by holding plug Also do not handle power cord with wet hands Doing so may cause electric shock Do not forcibly bend twist or pull power cord Also do not place heavy ob ject on power cord or damage or modify one Any of these may cause fire or electric shock due to damage to power cord Do not disassemble or modify this instrument or AC adapter Doing so may cause fire or electric shock Do not expose this instrument to liquid or metal object which may cause fire or electric shock Should either of these happen switch power off and unplug AC adapter immediately If used on batteries remove them and contact the nearest KONICA MINOLTA SENSING auth
70. is displayed p 90 Currently selected observer angle is displayed 2 10 p 32 Battery level mark 421 7 p 24 e is displayed when the finder shutter is set to au tomatically close for every measurement is dis played when set to always open p 48 SFT is displayed when this instrument is in SHIFT is displayed when SHIFT mode is released 18 19 Installing Use screw hole for fixing at the bottom of this instrument if utilized with tripod or jig 2 type holes are available Tripod screw hole To set on tripod Screw depth is 6 5 mm ISO screw hole To set on jig Use ISO screw with top diameter of 5mm and depth of 6 5 mm Standard plane for distance measurements 154 gt ISO screw Tripod screw ISO screw For other detailed dimensions see p 109 20 Hand Strap Hand strap can be used to carry this instrument with hand Adjusting hand strap Insert your right hand between this instrument and hand strap and adjust hand strap so that your hand securely fits to the instrument without any gap How to carry As shown in the figure insert your right hand through hand strap and support the bottom close to objective lens w
71. ith your left hand Tighten your arms to carry it more securely Notes on carrying Be careful not to thud this instrument when carrying You must always insert your right hand through hand strap 21 Connecting AC Adapter Either AC adapter accessory or 4 AA size batteries commercially available can be used as power source of this instrument zar 5 e a AN Wa rning Failure to adhere to the following points may result in death or serious injury Q Always use the AC adapter and power cord supplied as a standard accessory or optional AC A23 and connect it to indoor AC outlet of rated voltage and frequency Failure to follow either of these may result in damage to unit fire or electric shock Z If this instrument is not used for a long time disconnect AC adapter from AC outlet Accumulated dirt or water on prongs of AC adapter plug may cause fire and should be removed Do not forcibly pull any part on power cord when unplugging since this may cause fire or electric shock Gently disconnect by holding plug Also do not handle power cord with wet hands Doing so may cause electric shock Do not forcibly bend twist or pull power cord Also do not place heavy object on power or damage or modify one Any of these may cause fire or electric shock due to damage to power cord Do not disassemble or modify this instrument or AC adapter Doing so may cause fire or electric shock Should thi
72. iuoseg Dominant Wavelength In the x y chromaticity diagram shown below the curve VScSR is the spectrum locus and point N is the white point the chromaticity point of the perfect reflecting diffuser Colors located in the region enclosed by the spectrum locus and the straight lines VN and NR are referred to as spectral colors colors located in the triangle NVR with the white point N at the apex and the pure purple line VR as the base are referred to as non spectral colors Dominant wavelength spectral colors For spectral colors the dominant wavelength generally symbolized as Ad is the wave length corresponding to the point on the spectrum locus the curve VScSR where a line drawn from the white point through the chromaticity point obtained from the measured values intersects the spectrum locus In the example shown for a measured chromaticity point C the dominant wavelength is the wavelength corresponding to point S where the extension of line NC from the white point N through chromaticity point C intersects the spectrum locus Complementary wavelength non spectral colors For non spectral colors a line drawn from the white point through the chromaticity point obtained from the measured values does not intersect the spectrum locus the curve VS SR and instead intersects the pure purple line which has no corresponding wave lengths In such case the complementary wavelength generally symbolized as Ac is used instead
73. klight ON OFF 54 Setting Sleep Mode 56 Setting Internal Clock 58 Calibration 62 Calibration Channel 62 User Calibration 63 Implementing User Calibration 64 1 Through measurement 66 2 Through selection from saved data 68 3 Copy from other calibration channel 70 Numerical value entry ranges 71 Reset User Calibration 72 Setting CH ID Name 74 Entering Character 7T Setting and Changing Target Color 78 1 Through user calibration 79 2 Through measurement 80 3 Through selection from saved data 82 4 By entering numerical value 84 Measurement Measurement 88 Measuring distance and measuring area 88 Storing Measurement Value 90 Displaying Stored Data and 92 Setting Measurement Value ID Name Deleting Stored Data 94 Communication Connecting to PC 98 Remote Mode 99 Description Principle of Measurement 102 Spectral Fitting Method 102 EN VT 103 Dominant Wavelength 104 Measurement of Object Color 106 Operation Procedure 107
74. le based on coefficient set by user 1 Difference in instrument readings due to difference between CIE 1931 color matching functions and spectral sensitivity 2 Difference in instrument readings between units if multiple numbers of this unit are used This instrument employs monocalibration for user calibration Accurate measurement can be performed at luminance and chromaticity around calibration light source Jo O If you obtain calibration value by measuring a calibration light source with a prototype 3 standard set the prototype standard CS 200 in the same position and angle as amp S ss for the calibration light source and measure the same area If measurement conditions with the prototype standard and with CS 200 are different you fail to perform correct caliblation O Keep calibration light source as stable as possible with fixed voltage power source during measurement User calibration can be applied to every channel except for CHOO KONICA MINOLTA SENSING s correction coefficient has been set in all channels includ ing CHOO by the time of shipment This shall restore if user calibration is reset Color on which user calibration is based is to set as target color in the same calibration channel Target color serves as reference to determine how measured color deviates from refer ence User calibration can be done through either of following methods 1 Measurement 2 Select from stored
75. liquid off with clean water without rubbing eyes and immediately seek for medical professional s advice In case liquid contacts with hand or clothes wipe liquid off with plenty of water Avoid further use of such instrument Insulate battery contact with such object as tape in disposing of batteries Contact to other metal object may cause heat explosion or fire Follow local regulation for proper disposal or recycle of batteries Should instrument or AC adapter be damaged or smoke or odd smell be gen erated do not keep using it without correction Doing so may cause fire In such situations switch power off immediately unplug AC adapter or remove batteries in using ones and contact the nearest KONICA MINOLTA SENSING authorized service facility Failure to adhere to following points may result in injury or damage to instrument or other property Do not use batteries other than those specified by KONICA MINOLTA SENS ING Or do not use new and old batteries together or combine different type batteries When installing batteries in this instrument make sure that they are correctly placed according to and marks Failure to any of these may Caution damage battery or leak liquid resulting in fire injury or air pollution Note on Use Remove batteries if unused for 2 weeks or longer If not liquid in battery may leak which would damage this instrument To avoid draining of battery sleep mode setting is available f
76. mes worse especially when measurement time is FAST or Super FAST Measure in slower measurement time Is measurement sync Set appropriate measurement sync 30 frequency appropriate frequency for proper measurement when measuring dis play Haven t ambient tem Conduct measurement under envi 3 perature and humidity ronment free from such fluctuation rapidly changed 8 Strange Is objective lens clean Wipe off with dry and soft cloth or lens 106 measurement cleaning paper value ap pears Has user calibration Redo user calibration 64 been performed cor rectly Haven t you put close Select lens type setting correspond 62 up lens on ing to applied close up lens Haven t you put ND Select lens type setting correspond 40 filter on ing to applied ND filter 114 Error Symptom Item to Check Corrective Action Page to No Refer 9 Display of Is object to measure When an object whose luminance the remaining stable has changed greatly from the pre measurement vious measurement is measured time freezes measurement may be interrupted to and measure set the optimum gain for measure mentis not t and then remeasurement will completed men NN for the set be performed during remeasure measurement ment the remaining measurement time time display is frozen Keep object to measure stable Are you measuring an When an object whose luminance object whose lum
77. n Procedure MEMORY KEY LOCK MEAS SPEED ABS DIFF 1 Press ESC key when menu or target value setting menu appears Measurement screen appears on LCD screen 2 Press SHIFT key to switch to SHIFT mode SFT appears on left bottom Or make sure that SFT appears on left bottom indicating that this instrument has been operated in SHIFT mode 3 Press either Q or key to switch calibration channel and select one for which target color is to set Once target color is set calibration channel cannot be returned to previous status before setting Make sure to check channel number before overwriting 4 Press TARGET key lt TARGET gt screen appears lt MODE gt SINGLE SFT e 2 SELECT MEH DATA OR MEASURE NEXT ENTER SFT e 624 82 lt LENS gt STANDARD lt MEM gt AUTO NUM lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M000 NO DATA lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt HOLD DATA gt lt TARGET gt CH01 Display t Ly 5 Press SHIFT key to cancel SHIFT mode lt ANGD VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt HOLD DATA 6 Press either Q or key lt ANGL 1 VIEW lt SPD gt AUTO CH01 Display to select
78. ntinuous mode VALLEY is displayed when the mea surement result was obtained at VAL LEY for Continuous mode p 44 Nothing is displayed here when it was obtained at Single measurement or normal screen for Continuous mode Measurement result is displayed in the Ly currently selected color space Lyxy Lyu v LyTAuv XYZ Dominant wavelength p 34 cd m 0 3369 y 0 3256 SINGLE is displayed when the measurement mode is set to Single measure ment CONT is displayed when set to normal screen for Continuous mode p 42 Nothing is displayed here when set to lt PEAK gt or lt VALLEY gt for Continuous mode mode Setting status in this instrument is dis played lt ANGL gt Currently selected measuring angle is displayed 1 0 2 0 1 p 88 lt SPD gt Currently selected measuring time is displayed AUTO LTD AUTO S FAST FAST SLOW S SLOW MANU p 28 lt SYNC gt Synchronization frequency is displayed when internal sync measurement mode is set NO SYNC is displayed when it is not set p 30 lt LENS gt Currently selected lens type is displayed STANDARD No 107 No 122 p 40 lt MEM gt Update method for directory to store measurement value is displayed AUTO NUM MAN NUM AUTOSAVE p 46 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD Measurement value ID name p 92 Memory channel Stored data
79. o operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 3 Press MENU key three times MENU 3 4 Menu 3 4 screen appears on LCD screen LEEP MODE OFF DATE amp TIME BUZZER VERSION BREAK ESC e 2 4 Press ENTER key MENU 3 4 Inversion cursor moves from SLEEP MODE SLEEP MODE OFF to right to change setting for sleep mode DATE amp TIME BUZZER VERSION BREAK ESC le 2 56 5 Press either Q or to set 6 Press ESC key to return to lt SPD gt AUTO measurement screen Lv 20 80 lt MENU gt 3 4 either for ON or OFF SLEEP MODE y If ON is set this instrument operates in sleep DATE amp TIME mode when key operation or communication BUZZER has not been done for more than 30 minutes VERSION SLEEP MODE appears on LCD in sleep mode BREAK ESC me SLEEP MODE If measurement button or any key is pressed original screen appears after PLEASE WAIT Wherf PLEASE WAIT appears do not switch OFF Doing so may break stored data CH02 lt DEFAULT gt SANGI 1 VIEW SPD AUTO lt SYNC gt 200 00Hz PLEASE WAIT x 0 4155 lt MODE gt SINGLE y 0 4242 OE Press ENTER key lt MENU gt 3 4 Inversion cursor returns LEEP MODE ON to SLEEP MODE to fix setting DATE amp TIME BUZZER VERSION BREAK ESC E 3o 2 CHO0 XDEFAULT lt ANGL gt 1 VIEW SYNC 200 00Hz cd m lt LENS gt STANDARD Setting remains even after switching OFF
80. or the case not using for 30 minutes See p 56 for details If batteries are installed and AC adapter is used power is supplied through AC adapter Remaining Battery Level Mark Mark indicating remaining battery level appears on bottom left of LCD screen mark indicates that remaining battery level is low If this appears replacement with new ones or AC adapter connection is recommended mark indicates that there is no battery left This instrument cannot be used Re place with new ones or connect AC adapter Make sure that power switch is off before replacing batteries or connecting AC adapter 24 Placing Batteries 1 2 Make sure that power switch is OFF slided to mark side Open battery chamber cover while pressing and sliding d mark to the direction shown in illustration Place 4 AA size batteries following polarity indication in battery chamber Do no touch or short terminals in battery chamber Doing so may cause breakage of this instrument Use alkaline manganese lithium or nickel metal hydride batteries Slide battery chamber cover to the direction shown in illustration and close until clicking 25 iiu ON I OFF O of Power Switch To secure accurate measurement in either of following situations 15 minute warm up
81. orized service facility Do not dispose of batteries in fire short their terminals apply heat to them or disassemble them Doing so may cause explosion or liquid leakage resulting in fire or injury Should liquid leak from batteries and contact to eye wash liquid off with clean water without rubbing eyes and immediately seek for medical profes sional s advice In case liquid contacts with hand or clothes wipe it off with plenty of water Avoid further use of such unit Insulate battery contact with such object as tape in disposing of batteries Contact to other metal object may cause explosion or fire Follow local regulation for proper disposal or recycling of batteries Should this instrument or AC adapter be damaged or smoke or odd smell be generated do not keep using such instrument or AC adapter without correc tion Doing so may cause fire In such situations switch power off immedi ately unplug AC adapter or remove batteries in using ones and contact the nearest KONICA MINOLTA SENSING authorized service facility Do not look at sun or intense light through finder of this instrument This may lose your sight Failure to adhere to following points may result in injury or damage to this instrument or other property Use this instrument near AC outlet for easy plugging or unplugging in using AC adapter Do not use batteries other than those specified by KONICA MINOLTA SENS ING Do not use new and old batteries tog
82. partially discharged so switch power on to charge Battery can be fully charged in 20 hours Overcharge does not have to be worried about in this case Do not replace internal backup battery Type ML2030 3V by yourself Please contact the nearest KONICA MINOLTA SENSING authorized service facility e We recommend that you should backup important data with data management soft ware CS S10w Standard Edition as standard accessories to store separately Objective and Close Up lenses Optional e Make sure that surfaces of objective and close up lenses are clear Correct measure ment may not be performed if there is dirt dust hand soil or part left unclean Do not touch surface of objective or close up lens with hand Do not change ambient temperature rapidly under high humidity This may mist lens resulting in incorrect measurement Recommended batteries e Batteries themselves give poor performance at low ambient temperature which should cause to decrease the measurement frequency For power source of this instrument we recommend that you should use the lithium or nickel metal hydride batteries that are hardly affected by temperature change at low ambient temperature Storage Body Do not store this instrument under direct sunlight or near heater The internal temperature of this instrument to becomes much higher than ambient temperature which may break this instrument e Store this instrument at ambient temperature bet
83. pears Lv 92 74 lt SYNC gt NO SYNC cd m lt LENS gt STANDARD Measurement screen appears on LCD screen X 0 4185 wEw AUTO NUM y 0 4242 EEN DATA gt Lv 1 04 x 0 3772 y 0 3663 2 Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 46 3 Press SHUTTER key Icon indicating automatically closes for every measurement switches to icon meaning always opens in SHIFT mode Setting remains even after switching OFF O 47 CH00 lt DEFAULT gt lt ANGL gt 1 VIEW lt SPD gt AUTO Lv 92 74 SYNC NO SYNC cd m lt LENS gt STANDARD x 0 4185 MEM AUTO NUM MEMORY DATA M003 Lv 1 04 x 0 3772 y 0 3663 CH00 DEFADCX SPD AUTO Lv 92 74 ___ lt SYNC gt NO SYNC cd m lt LENS gt STANDARD x 0 4185 MEM AUTO NUM lt MEMORY DATA gt Lv 1 04 x 0 3772 Dunes IEE 0 Dunes Setting of Stored Data Protection Whether warning message appears or not is selectable for the case to store data in the memory channel with measurement value Setting at the shipment from factory ON Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT KEY LOCK m a ESC 2 3 1 7 6 Press ESC key when menu or target value setting menu appears Measurement scre
84. ress ENTER key Inversion cursor moves from parameter name to right to change setting for buzzer sound Press either Q or to set for either ON or OFF If ON is set for MEASUREMENT short blip sounds after measurement for OPERATION short blip when measurement button or related key is pressed and for WARNING repeated blip sounds for erroneous key operation or error message Press ENTER key Inversion cursor returns to parameter name to fix setting for buzzer sound Repeat procedures 6 and 7 as necessary Press ESC key twice to return to measurement screen Setting remains even after switching OFF O 53 lt BUZZER gt USN ON OPERATION ON WARNING ON BREAK ESC 9 JO lt BUZZER gt MEASUREMENT Sy OPERATION ON WARNING ON Dunes BREAK ESC e 2 lt BUZZER gt MEASUREMENT ON OPERATION ON WARNING ON BREAK ESC 2 me CH00 lt DEFAULT gt lt ANGL gt 1 VIEW SPD AUTO Lv 20 80 lt SYNC gt 200 00Hz cd m lt LENS gt STANDARD X 0 448 MEM AUTO NUM MEMORY DATA 8 6 DATA Lv y 0 448 lt MODE gt SINGLE le 2 Backlight ON OFF Whether turning backlight on LCD is ON or OFF is selectable Setting at the shipment from factory ON Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT v KEY LOCK S CO MENU ESC ENTER 2 1 3 1 Press ESC key when menu or tar
85. s SHIFT key to switch to SHIFT mode SFT appears on left bottom Or make sure that SFT appears on left bottom indicating that this instrument has been operated in SHIFT mode Press either Q or key to switch calibration channel and select one for which user calibration is to reset Once reset calibration channel to copy to cannot be returned to previous status before resetting Make sure to check channel number before copying Press SHIFT key to cancel SHIFT mode 72 lt SYNC gt 60 00Hz cd m lt LENS gt STANDARD lt MODE gt SINGLE le 2 lt MODE gt SINGLE SFT e 2 lt MEM gt AUTO NUM lt MEMORY DATA gt NO DATA Lv lt SPD gt AUTO SYNC 60 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM SYNC 60 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM MEMORY DATA M000 NO DATA MEMORY DATA NO DATA Lv 10 Press MENU key Menu 1 4 screen appears on LCD screen Press either Q or key to select lt CH SETTING gt and then ENTER key lt CH SETTING gt screen appears Press either Q or key to select CH RESET and then ENTER key lt RESET gt screen appears Press ENTER key Afte PLEASE WAIT appears and it is reset lt RESET gt screen appears Wherf PLEASE WAIT appears do not switch OFF Doing so may break stored data As in procedure 3 you can switch calibration channel to continue to reset o
86. s instrument or AC adapter be damaged or smoke or odd smell be generated do not keep using one without correction Doing so may cause fire In such situations switch power off immediately unplug AC adapter or remove batteries in using ones and contact the nearest KONICA MINOLTA SENSING authorized service facility Failure to adhere to following points may result in injury or Caution damage to instrument or other property Use this instrument near AC outlet for easy plugging or unplugging in using AC adapter 22 Connection Method 1 Make sure that power switch is OFF slided to O mark side 2 Lift protect cover and connect AC adapter plug to AC adapter input terminal on body P e 5 280 3 Plug AC adapter to outlet AC 100V 120V or 200 240V 50 Hz 60 Hz Insert AC adapter plug all the way seated in AC outlet If not may appear when turn ing power switch on Turn power switch off once and unplug AC adapter before resum ing See p 24 for details on mark 23 Placing Batteries AN Wa rning Failure to adhere to the following points may result in death or serious injury 5 e a Q Do not dispose of batteries in fire short their terminals apply heat to them or disas semble them Doing so may cause explosion or liquid leakage resulting in fire or injury Should liquid leak from battery and contact to eye wash
87. stored data lt SYNC gt NO SYNC Lv 90 41 0 4174 0 4137 DATA gt SELECT MEH DATA 90 78 OR MEASURE x 0 3872 NEXT ENTER y 0 3996 e 2 8 Ed oc 7 Press ENTER key sae VIEW 2g E 1 5 d PLEASE WAIT appears selected Lv 90 78 SLENS gt STANDARD value has been set as target color 5 z z lt MEMORY DATA gt o Wher PLEASE WAIT appears do not y 0 3996 m switch OFF Doing so may break stored data x 7 aea y 0 3996 8 Press ESC key to return to CHO1 lt DEFAULT gt T VIEW D measurement screen ee lt SYNC gt NO SYNC cd m lt LENS gt STANDARD X lt MEM gt AUTO NUM y MEMORY DATA NO DATA Lv lt MODE gt SINGLE 8 le 21 83 A v o o 1 Ed gt 2 10 m 4 By entering numerical value Operation Procedure MEMORY KEY LOCK MEAS SPEED ABS DIFF BACKLIGHT Press ESC key when menu or target value setting menu appears CH01 lt DEFAULT gt Measurement screen appears on LCD screen Press SHIFT key to switch to SHIFT mode SFT appears on left bottom Or make sure that SFT appears on left bottom indicating that this instrument has been operated in SHIFT mode Press either or key to switch calibration channel and select one for which target color is to set Once targe
88. strument Should any of these packaging materials or holding cap CS A24 be lost or broken please contact the nearest KONICA MINOLTA SENSING authorized service facility Note on Use Operating Environment Do not use this instrument outdoor since standard accessory AC adapter is designed for indoor use Do not disassemble this instrument for being composed of delicate electronic compo nents Use this instrument at rated voltage of 100 V 120 V 200 V 240 VW Connect AC power cord to AC outlet with rated voltage and frequency Connected voltage should not be outside the range of 10 of nominal This instrument is classified into a Pollution Degree 2 as instrument used in mainly in manufacturing plant laboratory warehouse or equivalents Use this instrument in metal dust free and non condensing potential environment This instrument is categorized into Installation Category Il as equipment connected to commercially available power source Connect PC for controlling this instrument to the outlet with protective grounding Failure to follow this may result in electric shock due to short circuit Take care not to enter foreign substance like water or metal in this instrument Operat ing in such state cause serious danger Do not use this instrument under direct sunlight or near heater The internal tempera ture of this instrument to becomes much higher than ambient temperature which may break this instrument Avoid rapid
89. supplied as standard accessory e Put all material including unit and accessories in original packaging material when returning this instrument for service Maintenance Periodical checkup is recommended annually to maintain measurement accuracy of instrument For details on checkup please contact the nearest KONICA MINOLTA SENSING authorized service facility Safety Precautions 2 Introduction 5 eiiam Rennn 3 Note on Use exu 3 Operating Environment 3 TMS MStHUIMONE 2 2 4 Backup Battery eee exin 4 Objective and Close Up lenses Optional 4 Recommended batteries 4 rennen erue 5 BOY eer he 5 Objective Lens rrr n 5 Cleaning 5 erinnern ines 5 lip 5 Objective Lens trennen 5 Notes on transfer 5 Maintenance 5 Standard Accessory 8 Optional Accessories 9 System Configuration 11 Names and Functions of Parts 12 Names of Each Part 12 Inside Finder eio 12 Functions of Each Part 13 Key Panel ne error ne 14 Main Functions of Each Key 14 SHIFT MOG ERE EE 15 Indicator Inside Finder 16 abore 16 0 2 Aperture 16 Ql Aperture
90. surement screen When ALL is set in procedure 5 press ESC key once 95 lt DELETE gt SELECT DATA AL OK TO DELETE OK __ ENTER CANCEL ESC le lt DELETE gt SELECT DATA moog OK TO DELETE OK ENTER CANCEL ESC le 2 lt DELETE gt OK TO DELETE M009 OK __ ENTER CANCEL ESC le 2 lt DELETE gt OK TO DELETE ALL OK ENTER CANCEL ESC le 2 lt DELETE gt SELECT DATA ALL OK TO DELETE OK __ ENTER CANCEL ESC o 2 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt MIE Lv 50 02 x 0 3666 y 0 3826 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M009 Lv 50 02 x 0 3666 y 0 3826 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt MIE Lv 50 02 x 0 3666 y 0 3826 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt moog Lv 50 02 x 0 3666 y 0 3826 lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt DATA ERE weep U9UoJISE oA 96 Communication 10
91. surement value appears on lt HOLD DATA gt of LCD after measurement is completed After measurement do not switch OFF until measurement value appears Doing so may break stored data This measurement is corrected with user calibration value for selected calibration channel Press ENTER key Afte PLEASE WAIT appears measurement value has been set as target color Wherf PLEASE WAIT appears do not switch OFF Doing so may break stored data Press ESC key to return to measurement screen 81 lt TARGET gt lt ANGL gt 1 VIEW CHU Display 1 lt SPD gt AUTO lt SYNC gt NO SYNC Lt tots SLENS gt STANDARD lt gt lt HOLD DATA gt SELECT MEH DATA Lv 90 41 OR MEASURE x 0 4174 NEXT ENTER y 0 4237 SFT 2 lt gt lt ANGL gt 1 VIEW CH01 Display 1 lt SPD gt AUTO SYNC 200 00Hz Lv 90 41 m SLENS gt STANDARD X 0 4174 MEM AUTO NUM lt HOLD DATA gt y 0 4237 Lv 90 41 lt MODE gt SINGLE x ee SFT e 2 PAS lt ANGL 1 VIEW SPD AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD MEM AUTO NUM MEMORY DATA M000 NO DATA CHO lt DEFAULT gt lt MODE gt SINGLE SFT e 2 3 1 A v o o 1 Ed gt 2 10 m 3 Through selection from saved data Operatio
92. surement value is to store in M005 after MEMORY key is pressed and number of memory channel displayed in MEMORY DATA is replaced to M006 AYOWAWN If AUTOSAVE is set measurement value will be saved automatically after measurement and memory channel number changes accordingly For example if M005 is displayed measurement value is to store in M005 after measurement is performed and number of memory channel displayed in MEMORY is replaced to MOO6 In case of MAN NUM measurement value is to store memory channel of which number is shown then For example if MOO5 is displayed measurement value is to store in M005 and nunber of memory channel displayed in MEMORY DATA remaines M005 With AUTO NUM or AUTOSAVE and M100 has been used up data goes back to MOOO again When data storage is to perform on memory channel with another measurement value a warning message appears Warning message OK TO OVERWRITE appears If OK press ENTER key and if not ESC key Setting is available not to display such message See p 50 Press ESE key to stop 6 Press ENTER key lt MENU gt 2 4 Inversion cursor returns to OBJECTIVE LENS STANDARD MEMORY MODE Now change has been set DISPLAY DIGITS 4 FIGURES MEMORY MODE AUTOSAVE DATA PROTECT ON BREAK ESC go 2 7 Press ESC key to return to CH00 lt DEFAULT gt ee TUE measurement screen Lv 20 80 SYNc cd m lt LENS gt STANBA remains e
93. t color is set calibration channel cannot be returned to previous status before setting Make sure to check channel number before overwriting Press TARGET key lt TARGET gt screen appears lt MODE gt SINGLE SFT e 2 SELECT MEH DATA OR MEASURE NEXT ENTER SFT e 624 84 lt ANGL 1 VIEW lt MEMORY DATA gt Maoa DATA lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M000 NO DATA lt ANGL gt 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt LENS gt STANDARD lt MEM gt AUTO NUM 10 Press TARGET key to go to target color entry screen Enter target color in numerical value Q key O to 9 in ascending order K M decimal point and space available If kept pressed value continuously changes key 9 to 0 descending order K M decimal point and space available If kept pressed value continuously changes and M show x10 and x10 respectively See p 71 for details on Numerical value entry ranges Press 6D key to move the cursor to second digit position Repeat procedures from 6 to 7 as necessary to enter target color of Lv x and y respectively Press ESC key to stop Press ENTER key Afte PLEASE WAIT appears entered value has been set as target color Wherf PLEASE WAIT appears do not switch OFF Doing so may break stored data Press ESC key
94. ther calibration channel Note that original calibration channel appears when you return to measurement screen in procedure 10 Press ESC key three times to return to measurement screen 7 lt MENU gt 1 4 CH SETTING MEAS MODE SYNC MODE DELETE me SINGLE BREAK ESC o CH SETTING CHO1 lt DEFAULT gt USER CA CH ID NAME CH COPY CH RESET BREAK ESC le 2 lt CH SETTING gt CHO1 lt DEFAULT gt USER CAL CH ID NAME CH COPY RESET BREAK ESC le 1 lt lt RESET gt cH Lv 100 77 x 0 3945 y 0 4000 OK TO RESET THIS CH OK ENTER CANCEL ESC e 2 CHO1 XDEFAULT KANGL 1 VIEW lt MODE gt SINGLE le 2 el 93 1uouoJnsee y SSS v o 5 gt lt m S etting CH ID Name CH ID name indicates name given to each calibration channel by entering characters CH ID name appears on LCD screen in measurement together with calibration channel It is helpful if for which object user calibration or target color setting has been done is entered e Available number of characters for entry 9 max e Available character type for entry A to Z a to z space O to 9 symbol Operation Procedure MEMORY v KEY LOCK MEAS SPEED ABS DIFF ED uL MENU ESC 2 4 5 1 12 BACKLIGHT 1 7 11 1 Press ESC key when menu or target value set
95. ting menu appears Measurement screen appears on LCD screen Press SHIFT key to switch to SHIFT mode SFT appears on left bottom Or make sure that SFT appears on left bottom indicating that this instrument has been operated in SHIFT mode Press either calibration channel and select one for CH ID name setting 74 Q or key to switch CH01 lt DEFAULT gt lt MODE gt SINGLE le 2 lt MODE gt SINGLE SFT e 2 3 6 7 8 XANGD 1 VIEW SPD AUTO SYNC 60 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt DATA Lv lt ANGL 1 VIEW lt SPD gt AUTO SYNC 60 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M000 NO DATA lt LENS gt STANDARD lt MEM gt AUTO NUM Press SHIFT key to cancel SHIFT mode Press MENU key Menu 1 4 screen appears on LCD screen Press either Q or key to select CH SETTING and then ENTER key lt CH SETTING gt screen appears Press either Q or key to select CH ID NAME and then ENTER key lt CH ID NAME gt screen appears Enter CH ID name A to 2 in descending order and space If kept pressed character switches continuously Z to Ain ascending order and space If kept pressed character switches continuously Small alphabets numerical values and symbols are also available See p 79 for details 75 lt ANGL gt 1 VIEW lt SPD gt AUTO SYNC 60 0
96. to return to measurement screen 85 lt TARGET gt lt ANGL gt 1 VIEW CH01 Display 1 lt SPD gt AUTO L lt SYNC gt NO SYNC Veeco SLENS gt STANDARD lt gt SET CAL VALUE ENTER SFT 2 lt TARGET gt lt ANGL gt 1 VIEW CH01 Display 1 lt SPD gt AUTO L lt SYNC gt NO SYNC y eb cd m SLENS gt STANDARD peers lt MEM gt AUTO NUM y SET CAL VALUE OK ENTER SFT e 2 lt TARGET gt lt ANGL gt 1 VIEW CH01 Display 1 lt SPD gt AUTO L lt SYNC gt NO SYNC V 9 lt LENS gt STANDARD e MEM AUTO NUM y SET CAL VALUE OK ENTER SFT e 2 lt TARGET gt lt ANGL gt 1 VIEW CH01 Display 1 lt SPD gt AUTO lt SYNC gt NO SYNC Lv 90 78 im lt LENS gt STANDARD ART MEM AUTO NUM y SET CAL VALUE OK ENTER SFT e 2 lt TARGET gt lt ANGL gt 1 VIEW CH01 Display 1 lt SPD gt AUTO lt SYNC gt NO SYNC Lv 90 78 cd m SLENS gt STANDARD 0 3545 MEM AUTO NUM y 0 3965 SET CAL VALUE OK ENTER SFT e 2 lt gt lt ANGL gt 1 VIEW lt SPD gt AUTO ly eno lt SYNC gt NO SYNC cd m lt LENS gt STANDARD X MEM AUTO NUM MEMORY DATA gt M000 NO DATA lt MODE gt SINGLE SFT 2 3 1 86 Measurement ju
97. urement For recalculation press RECALC key if measurement screen is in SHIFT mode after changing calibration channel Recalculation can be done only for measurement data not for stored data Keep following procedure to select memory channel before measurement if memory channel to store measurement value in is to specify in advance Press Q or key to switch memory channel if measurement screen is not in SHIFT mode 89 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt NO DATA CH01 lt DEFAULT gt lt MODE gt SINGLE le 2 lt ANGL 1 VIEW lt SPD gt AUTO CH00 lt DEFAULT gt Lv 20 80 SSYNC gt 200 00Hz x 0 4476 y 0 4477 m lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt lt MODE gt SINGLE Je 2 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt 200 00Hz lt LENS gt STANDARD lt MEM gt AUTO NUM lt MEMORY DATA gt M000 NO DATA CHIC DEFAULT u w nse lt MODE gt SINGLE SFT e 2 D OPE MEMORY MEAS SPEED BACKLIGHT YKEY LOCK 8 E CH00 lt DEFAULT gt lt ANGL gt 1 VIEW SPD AUTO SSYNC gt 200 004 cd m lt LENS gt STBA 75 c JAM 5 VESC lt MEMORY DATA gt NO DATA lt MODE gt SINGLE le 2 AY 1uouleJnsee Storing Measurement Value
98. ursor to second digit position Repeat the same procedures 6 and 7 as necessary Selectable frequency range is from 40 00Hz to 200 00Hz Press ESE to stop SYNC MODE NOSYNC 60 0092 SYNC OK ENTER CANCEL ESC 2 je lt SYNC MODE gt NO SYNC 26000 SYNC OK ENTER CANCEL ESC le 2 lt SYNC MODE gt NOSYNC 280009 SYNC OK ENTER CANCEL ESC Je 2 lt SYNC MODE gt NOSYNC 2000092 SYNC Press ENTER key to show lt MENU gt 1 4 screen Now frequency has been set Press ESC to return to measurement screen Internal sync mode setting remains even after switching OFF O OK ENTER CANCEL ESC le 2 MENU 1 4 CH SETTING MEAS MODE SINGLE SYNC MODE DELETE 1e BREAK ESC 2 CH00 lt DEFAULT gt lt ANGL gt 1 VIEW 2 SYNC gt 200 00Hz cd m LENS STANDARD cone MEMORY DATA 8 8 DATA Lv lt MODE gt SINGLE le 2 Buas lt CENERE Dunes 5 etting Observer Color matching function for chromaticity calculation is selectable between 2 and 10 Setting at the shipment from factory 2 OBS Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT KEY LOCK C n ESC 2 3 1 7 6 Press ESC key when menu or target value setting menu appears Measurement screen appe
99. usly changes Q9 Number decreases in ascending order If kept pressed number continuously changes Measurement value stored in memory channel 92 SPD AUTO SYNC 60 00Hz cd m LENS STANDARD MEM AUTO NUM lt DATA CH 2 LENS cd m EM AUTO NUM HOLD DATA lv 50 03 x 0 3473 NONAME ENTER y 0 3504 le 2 lt ANGL 1 VIEW lt SPD gt AUTO lt SYNC gt NO SYNC lt DATA CH02 lt DEFAULT gt Lv 50 02 jen lt LENS gt STANDARD lt MEM gt AUTO NUM lt HOLD DATA gt Lv 50 03 x 0 3473 y 0 3504 x 0 3369 y 0 3256 NO NAME ENTER le 2 appears Stored data is displayed on the condition when measurement was made However converted form in current color space for this instrument appears for color space To return to measurement screen press either or Q or ESC key Measurement value ID Name can be given to stored data Measurement value ID Name refers to name to each stored data by entering characters It appears on LCD screen together with channel number It is helpful if for which object user Measurement value ID Name has been used Available number of characters to enter 9 max Available type of characters to enter A to Z a to z space 0 to 9 symbol Press ENTER key Measurement value ID Name appears on LCD screen Enter Measurement value ID Name e A to Z in descending order and space If kept pr
100. v 20 80 lt SYNC gt 200 00Hz cd m lt LENS gt STANDARD X 0 4476 lt MEM gt AUTO NUM MEMORY DATA y 0 4477 M SI9 e NO DATA Lv lt MODE gt SINGLE le 2 eo eo 117 uonduoseq Changing Luminance Unit You can select cd m or fL as luminance unit Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT VKEY LOCK 1 Follow procedures from 1 to 4 in lt VERSION gt Ident ifying Version p 118 to display lt VERSION gt screen on LCD screen VER 1 00 0000 S N 0000000 BREAK ESC le 2 2 Press SHIFT key MENU key and lt LUM UNIT gt key at the same time LUM UNIT LCD lt gt appears on screen tL OK E CANCEL ESC 1 2 3 Press key key to select LUM UNIT cd m or fL Press ESC key to stop cd m2 OK ENTER CANCEL ESC Je 2 118 4 Press ENTER key lt VERSION gt lt VERSION gt screen appears on LCD screen VER 1 00 0000 S N 0000000 BREAK ESC le 2 D Press ESC key twice CHOO DEFAULT lt ANGL gt 1 VIEW SPD AUTO Lv 6 07 SYNC 200 00Hz fL lt LENS gt STANDARD X 0 4476 MEM AUTO NUM MEMORY DATA y 0 4477 979 9 DATA Measurement screen appears on LCD screen lt MODE gt SINGLE le 2 pm J eo eo 119 ii n 3 Specification
101. ven after switching OFF O x 0 4476 y 04477 NC DATA Lv lt MODE gt SINGLE le 2 51 EPZA Dunes Buzzer Settin This instrument usually generates buzzer sound for key operation but setting for buzzer sound is switchable Buzzer for measurement operation and error can be set indepen dently Setting at the shipment from factory ON for MEASUREMENT OPERATION and WARNING Operation Procedure MEMORY MEAS SPEED ABS DIFF BACKLIGHT KEY LOCK ESC 2 3 1 9 7 4 5 6 1 Press ESC key when menu or target CH00 lt DEFAULT gt 3 w value setting menu appears Lv 20 80 lt SYNC gt 200 00Hz cd m lt LENS gt STANDARD Measurement screen appears on LCD screen 0 4476 lt MEM gt AUTO NUM lt MEMORY DATA gt y 0 4477 Maoa DATA Lv 2 Make sure that appears on left bottom indicating this instrument has not been set for SHIFT mode If SFT appears instead it means that instrument is to operate in SHIFT mode Press SHIFT key to cancel SHIFT mode 3 Press MENU key three times MENU 3 4 Menu 3 4 screen appears on LCD screen LEEP MODE OFF DATE amp TIME BUZZER VERSION BREAK ESC le 4 Press either Q or key to select lt MENU gt 3 4 BUZZER and then ENTER key SLEEP MODE OFF lt BUZZER gt screen appears DATE amp TIME BUZZER VERSION BREAK ESC le 2 52 9 Press either Q or key to select parameter to change and then p
102. ween 0 and 40 and relative humid ity 8596 or less at 35 C with no condensation Storage under high temperature and humidity may deteriorate performance of this instrument For added safety we rec ommend storage with such drying agent at room temperature e Take care not to form condensation Avoid rapid change in ambient temperature when transferring body for storage e Put body in packaging box supplied when purchased or optional soft case CS A23 to store in safe place Objective Lens For storage cover with standard accessory lens cap Cleaning Body e fthis unit becomes dirty wipe with dry and soft cloth Do not use organic solvent like ben zine or thinner and other chemical agent for cleaning Should none of these methods be helpful please contact the nearest KONICA MINOLTA SENSING authorized service facility Objective Lens e Should it be gotten dirt or dust wipe off with dry and soft cloth or lens cleaning paper Do not use organic solvent like benzine or thinner and other chemical agent for clean ing Should none of these methods be helpful contact the nearest KONICA MINOLTA SENSING authorized service facility Notes on transfer Use packaging material supplied when purchased to minimize vibration or shock generated during transfer Use holding cap for the same purpose especially to protect optical system of this instrument Set measur ing angle selector at center 0 2 and cover with holding cap CS A24
103. with this spectral response and gained tristimulus values X Y and Z are converted into Lyxy L u v L TAuv and dominant wavelength through calculation to be displayed as measurement value CIE 1931 CIE 1931 color matching functions color matching functions Z A xQ _ Z A YA 1 04 1 04 gt 4 me d o Spectral sensitivity of o m conventional tristimulus Spectral sensitivity colorimeters of the CS 200 o o0 o l Dd M Dd fh QQ vvv o P fF fF QQ ccv 205 P bef J WA 205 XY fF fF VY s S NM J FP fF NV aa a 380 400 500 600 700 780 380 400 600 700 780 Wavelength nm Wavelength nm CIE 1931 color matching functions and spectral response CIE 1931 color matching functions and spectral response of a conventional tristimulus colorimeter of the CS 200 Chromaticity coordinates x y in Lvxy CIE 1931 color space can be obtained through following formula A y X Y Z X Y Z X Y and Z are tristimulus values uoldiuoseg 102 L T uv Following factors can be acquired as measurement value with LvT d uv as color space of this instrument L Luminance T Correlated color temperature Auv Color difference from blackbody locus While L stands for luminance T and Auv for color in LyTAuv Relation between correlate
104. xy Lvu v LvT d uv XYZ and dominant wavelength in one calibration channel No target color has been set for calibration channel without target color set by the time of shipment from factory Only appears In the target setting screen the target data for a channel other than the displayed channel may be displayed If this occurs use the up down keys to temporarily select a different channel and then return to the desired channel The correct data will then be displayed When the display is switched repeatedly between the TARGET screen and USER CAL DATA screen while checking data the target data shown in the lt TARGET gt screen may be the data for a different target channel than the channel number which is shown For example if the channel is set to CHO1 in the lt TARGET gt screen and then the screen is changed to the USER CAL DATA screen and CHO2 is selected and then the screen is changed back to the TARGET screen the channel display continues to show 2 but the displayed data are actually the data for CHO1 78 1 Through user calibration Calibration value is simultaneously set as target color if user calibration is performed in calibration channel from 1 to CH20 No further target color setting is needed if target color has been fixed for calibration channel Follow below next page only when target color set in CHO1 to CH20 needs to change or target color is needed to set in KONICA MINOL
105. y 10 cd m and higher SLOW average of 10 measurements 2 At 0 2 Measuring angle the amount of received light is approx 1 25 of that for 1 Therefore the repeatability becomes the same as that for 1 with 25 times lower luminance 0 1 Measuring angle the amount of received light is approx 1 100 of that for 1 Therefore the repeatability becomes the same as that for 1 with 100 times lower luminance 120 121 KONICA MINOLTA 9222 1892 11 2005 KONICA MINOLTA SENSING INC AHEEPK Printed in Japan
Download Pdf Manuals
Related Search
Related Contents
rapport final de synthèse sur l`étude facteurs humains en Samsung PS-42C7S User Manual Hoover 4080 Vacuum Cleaner User Manual GERADOR DE FUNÇÕES MFG-4202 MANUAL DE INSTRUÇÕES メッセージを読む 2015 ENG Rotary broom HT user manual EPSON Stylus Photo R220/R230 Color Inkjet Printer Bedienungsanleitung/Garantie 89 Copyright © All rights reserved.