Home
Intel cc2300 Server User Manual
Contents
1. Cc2300 cc3300 Alerting In Band ISC paging Y SNMP for Enterprise Sys Mgt Con Y Desktop Management Interface indication Y Network alerts pop up messages Y Alerting Out Of Band Platform Event Paging Y OOB LAN alerts SNMP traps Y BIOS Console Redirection Over modem serial Y Over LAN Y Direct Platform Control Console Management Plug In Server control Y Console redirection Y System Event Log manager Y Sensor Data Records manager Y Field Replaceable Unit manager Y Remote Sensor Access manager Y Auto answer on modem Y Ease of Use Online help Y Documentation Y Java based GUI N Fans Fan pack digital N Fan pack tach N Individual fans digital N Individual fans tach Y Hot Swapping Hot swap disk drives N Hot swap power supply Y Hot swap fans N 1 continued 18 Intel Server Control Installation Guide Table 1 Platform Compatibility Matrix continued Board Chassis Cc2300 cc3300 Industry Design Standards IPMI 0 9 compliant N IPMI 1 0 compliant N IPMI 1 5 compliant Y Monitoring Component temperatures Y Fan speeds Y Baseboard voltage Y Baseboard sensors Y Chassis intrusion N Drive availability Y Power supply health Y Power supply redundancy Y OOB Emergency Management Remote power control on off reset Y Access to non volatile logs Y Remote sensor access Y Service partition
2. Remove the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD from the drive You can now install the user operating system NOTE More information about the service partition can be found in the Service Partition Administration utility Boot the Server from the Service Partition Boot the server from the service partition to run the utilities found on the service partition You can reboot a server Intel Server Control Installation Guide e Locally e Remotely using the DPC Console Manager e Remotely using Client SSU Locally Booting the Server from the Service Partition Depending on the server platform the BIOS may give you an option to directly boot the Service Partition at startup If not you can boot the Service Partition by making a change in BIOS Setup 1 Restart the server 2 Ifyou see a message like press F2 to enter Setup press F4 to boot the Service Partition simply press F4 Ignore the following steps 3 If there is no option to boot the Service Partition directly when the F2 to enter Setup message appears quickly press F2 to enter Setup 4 In Setup use the arrow keys to select the Server menu 5 Select Service Boot and press Enter 6 Choose Enabled and press Enter The Service Boot option resets to Disabled after the next system boot Press F10 8 Select Yes to confirm saving of the current settings and press Enter The server restarts and boots the
3. Network Node Manager e LANDesk Server Manager LDSM e CA Unicenter TNG Once the ISC application is launched from an enterprise management console the management console application can terminate and ISC will continue to operate normally ISC can be launched from and can manage your server from a stand alone ISC Console The ISC Console can run as an executable program as an ActiveX control within an Internet browser or within Microsoft Management Console 16 Intel Server Control Installation Guide Intel Server Control H P Network Node Manager The H P Network Node Manager Console autodetects servers running the ISC Server Instrumentation software The Console updates the server bitmap with an ISC server icon for those servers To launch the ISC applet select an ISC enabled server on the H P Console network map and then select the Intel Server Control Applet option from the Tools Menu Alternatively you can launch ISC by selecting an ISC enabled server on the H P console network map clicking the right mouse button and then selecting the Intel Server Control option from the popup menu LANDesk Server Manager The LANDesk Server Manager LDSM console dynamically builds its feature set when communication is established with a managed server If the managed server is running ISC the LDSM console adds an option for IntelIntel Server Control in the Tools branch of the LDSM navigation tree Select this option to lau
4. ad ange paren A EE cae 17 VSG COMSGI E ascarid ste ses scientist E he tien aces asec nie ata tai andl aie ccc E us cclee eke 17 HP Carrier Grade Server Functionality Matrix eeeeeeeeeeeeeeeeeeeeeeeeeees 18 Intel Server Control Installation Guide Intel Server Control This guide explains how to install and launch the Intel Server Control ISC software ISC is a server management tool that provides real time monitoring and alerting for server hardware emergency remote management and remote server setup ISC is implemented using a client server architecture and has been developed for the HP Carrier Grade cc2300 and cc3300 servers Servers can be managed by the client through a LAN a direct RS 232 serial connection or a RS 232 connection through a modem The Direct Platform Control DPC component of ISC accesses system log and sensor information through the Baseboard Management Controller BMC independent of the cc2300 or cc3300 operating system The server needs to be powered up for DPC access through LAN or RS 232 The Platform Instrumentation Control PIC accesses system log and sensor information online by utiltizing the cc2300 or cc3300 operating system The server s operating system needs to be booted to run PIC PIC is accessed through LAN or RS 232 System Requirements Overview ISC contains two parts e ISC Console Software e ISC Server Instrumentation Software The ISC console software is installed on a
5. all such guaranties warranties and licenses including but not limited to fitness for particular purpose merchantability not infringement of intellectual property or other rights of any third party or of HP indemnity and all others The reader is advised that third parties may have intellectual property rights that may be relevant to this document and the technologies discussed herein and is advised to seek the advice of competent legal counsel without obligation to HP The Intel Server Control product may contain design defects or errors known as errata that may cause the product to deviate from published specifications Currently characterized errata are available on request Intel Pentium and LANDesk are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries t Other names and brands may be claimed as the property of others Copyright 2002 Hewlett Packard Corporation Intel Server Control Installation Guide Contents Intel Server Control zxcccsccceeirrie teeter ene eed acd eee eae cee 4 System Requirements Overview cccccccccsssseeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeeeeeseeeeeseees 4 Windows 2000 Requirements sszccesxcrie eacenuevis Muanctasesveverctyelescodel aadeueetens Genet addeeeanisonns 4 Red Hat Linux 7 1 Requirements ccciecdc tices ucdeeneia ti teed sechisneedvnetiatinw tba Gin sateateddartes ence 5 Additional Requirements for DMI SNMP Translatio
6. client The ISC server instrumentation software is installed on the HP Carrier Grade cc2300 cc3300 Servers ISC Console Software allows interaction with the managed server It can be installed on these system client configurations e Windows NT 4 0 server Enterprise Edition Service Pack 6a e Windows NT Workstation Service Pack 6a e Windows 2000 Advanced Server Service Pack 2 e Windows 2000 Professional Service Pack 2 ISC Server Instrumentation Software when installed on the cc2300 or cc3300 servers creates a managed server that can be managed from the system client running ISC Console Software ISC is supported on e Windows 2000 Server Service Pack 2 e Linux RedHat 7 1 Windows 2000 Requirements e Windows 2000 Advanced Server Service Pack 2 e 64 MB of RAM e 60 MB of available disk space SNMP service installed required only for connectivity to an SNMP management console Intel Server Control Installation Guide Red Hat Linux 7 1 Requirements If you intend to manage a Linux file server it must meet the following minimum requirements e Linux Red Hat 7 1 or Red Hat Enterprise Linux AS 2 1 operating system running multiple processor kernel e 32 MB of RAM e 60 MB of available disk space Additional Requirements for DMI SNMP Translation Simple Network Management Protocol SNMP support must be installed if you want to integrate ISC with an SNMP based management framework On the managed server you should c
7. service partition Remotely Booting the Server from the Service Partition You can remotely boot the server from the service partition using the DPC Console Manager or Client SSU Select Reboot to Service Partition in the DPC Console Manager or boot to the service partition by launching the Client SSU The server s operating system will automatically be shutdown prior to booting into the service partition Exiting the DPC Console Manager or Client SSU will exit the service partition and will reboot the server s operating system Configuring the Server for EMP Access To take advantage of DPC and CSSU features the Emergency Management Port EMP and console redirection settings must be configured using the Server System Setup Utility Server SSU The EMP is accessed through the server s COM 2 port by a direct or modem connection 1 Insert the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD into the CD drive Restart the server When the F2 to enter setup message appears quickly press F2 In Setup use the arrow keys to select the Boot menu Use the arrow keys to select Boot Device Priority then press Enter Select ATAPI CDROM and use the key to move the selection to the top of the list Press F10 Select Yes to confirm saving of the current settings and press Enter The server restarts and boots from the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utiliti
8. the server Server will reboot and the Intel Server Control installation program will launch to complete the ISC installation Intel Server Control can be run by selecting Start gt Programs gt Intel Server Control The ISC Console is the primary console used to list the available server management tools 13 Intel Server Control Installation Guide ISC Installation Procedure for Linux Red Hat 7 1 and Red Hat Enterprise Linux AS 2 1 There are three steps to the Linux Red Hat installation process 14 Installing Linux DMI server provider Installing ISC Configuring the SNMP_DMI mapper Installing Linux DMI Service Provider Insert the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD into the Linux server CD ROM drive Mount the CD using either of the following methods e Enter the mount command as follows mount mnt cdrom e Use the Disk Management utility To invoke this utility click the Start button select System and then select the Disk Management menu option NOTE If you prefer a quicker method for installing ISC on RedHat 7 1 look for the installation script that is included in the driver tab of the cc2300 cc3300 Resource CD Uninstall the ucd snmp version 4 2 software package if it has been installed previously with rpm e ucd snmp version 4 2 software is included with RedHat 7 1 ISC runs with ucd snmp version 4 1 Check for ucd snmp version 4 2 using the RP
9. 0 MB of available disk space e Microsoft Windows compatible modem must be used if you connect to the server by modem Intel Server Control Installation Guide Service Partition The service partition is a special hard disk partition The service partition has been installed on the HP Carrier Grade cc2300 and cc3300 Servers The service partition size is 40Mbytes The service partition contains utilities and other software required for remote management The service partition is not marked as an active partition and the server will only boot from it by a special request It is not normally visible to the server user because it has a special non standard partition type that does not appear as an accessible file system to the end user operating system However low level disk utilities may see the partition entry as an EISA partition and recognize its space The utilities on the service partition can be run locally or remotely In order to run the utilities the server must boot from the service partition Remote execution is available from the Direct Platform Control DPC Console Manager and the Client System Setup Utility CSSU Service Partition Installation It is recommended that you install the service partition e Ona clean hard drive with no partitions defined e Before installing any operating system The service partition should not be installed if the operating system has already been loaded The operating system may not boot if th
10. DPC Console 1 Connect to the appropriate server 2 Select Reboot Service Partition from the Action menu Using the Client System Setup Utility CSSU Select Re Connect from the Server menu Enabling LAN Events LAN Events are disabled by default and need to be enabled during cc2300 cc3300 server setup LAN events are passed to the LAN Event Viewer software on the client 1 OSD Bay 10 11 12 13 14 15 16 17 18 Insert the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD into the CD drive Restart the server When the F2 to enter setup message appears quickly press F2 In Setup use the arrow keys to select the Boot menu Use the arrow keys to select Boot Device Priority then press Enter Select ATAPI CDROM and use the key to move the selection to the top of the list Press F10 Select Yes to confirm saving of the current settings and press Enter The server restarts and boots from the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD When the menu appears use the arrow keys to select the Utilities menu and press Enter Select Run System Setup Utility under the Utilities menu You will see SSU executables installed the first time and then the Server SSU launches In the Available Tasks list select Platform Event Manager and click OK Select Configure PEP Click on Options and select Con
11. Intel Server Control Installation Guide For the HP cc2300 amp cc3300 Carrier Grade Servers Document Release Date March 2003 Legal Information Intel Server Control System Requirements Overview Service Partition Enabling LAN Events Installing Intel Server Control ISC Launching Intel Server Control ISC HP Carrier Grade Server Functionality Matrix Intel Server Control Installation Guide Legal Information Hewlett Packard Corporation HP makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose HP assumes no responsibility for any errors that may appear in this document HP makes no commitment to update nor to keep current the information contained in this document No part of this document may be copied or reproduced in any form or by any means without prior written consent of HP An HP product when used in accordance with its associated documentation is Year 2000 Capable when upon installation it accurately stores displays processes provides and or receives date data from into and between the twentieth and twenty first centuries including leap year calculations provided that all other technology used in combination with said product properly exchanges date data with it Nothing in this document constitutes a guarantee warranty or license express or implied HP disclaims all liability for
12. M RedHat Package Manager query command Rpm q ucd snmp Output should be Ucd snmp 4 2 12 Type in Rpm e ucd snmp A message should state ucd snmp utils and ucd snmp devel are dependent upon ucd snmp Remove ucd snmp utils ucd snmp devel and then ucd snmp using the following commands Rpm ucd snmp utils Rpm ucd snmp devel Rpm ucd snmp Intel Server Control Installation Guide NOTE If you uninstall ucd snmp you must also remove all related snmp and DMI packages When you remove these packages remove them in an order that eliminates dependency error messages For example if a dependency error message appears remove the package mentioned in the error message Continue removing the dependent packages in this manner until the error messages stop 4 Install the DMI service provider package located in the Software Linux dmisnmp directory on the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD by using the rpm command For example the following command installs a version of the DMI service provider package rpm i dmisp 1 0 6 i386 rpm 5 Locate and install the ucd snmp RPM ucd snmp utils RPM and dmi2snmp RPM packages These packages are also located in the Software Linux dmisnmp directory on the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD Use the rpm command to install each package For example the following three commands insta
13. Y OOB Remote Management Intelligent Chassis Management Bus Y Direct Platform Control over LAN Y Command for graceful OS shutdown Y Enterprise Server Mgmnt Console HP OpenView Network Node Manager 6 1 Y CA Unicenter Framework TNG 2 4 Y LDSM 6 1 build 54 Y Web Browser MS IE 5 6 Netscape 6 0 Y Microsoft MMC v1 2 Y ISC standalone Y Remote Access LAN in band OS up Y LAN OOB OS down Y Modem OOB OS down Y Remote Boot Access Service Partition Over modem serial Y Over LAN Y Remote Diagnostics OOB hardware diagnostics N continued 19 Intel Server Control Installation Guide Table 1 Platform Compatibility Matrix continued Board Chassis cc2300 cc3300 Remote Management in band Desktop Management Interface 1A32 Y Platform Instrumentation Control Y Remote Repair FW upgrades Y BIOS upgrades Y File upload and execution Y Security CHAP Compliance Y Passwords Y Service Partition Client System Setup Utility remote access Y DOS shell access command prompt Y File transfer Y 20
14. e service partition is installed after operating system installation Some hard drives may have free entries in the partition table with 40MB of available space Utilizing the freeentry is not recommended Requirements e The service partition can be on any of the first 4 BIOS supported physical hard drives e Service partition hard drives must support BIOS 22 e Current BIOS must be installed e Remove old service partitions and create the new service partition with a current HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD e Atleast 40 MB of unused not partitioned hard drive space is required On large hard drives this unused space must be within the first 8 GB NOTE There are commercial utilities that can resize existing partitions to free space if more is needed Alternately you can add a low capacity hard drive for the service partition Installation This procedure is for installing the service partition on unpartitioned hard drive only Intel Server Control Installation Guide NS 020 OY Ov E 15 16 17 18 19 20 21 22 CAUTION To prevent data loss do not attempt to run the installation utility from any device other than the HP Server cc3300 amp cc2300 User Information Diagnostics and Utilities Resource CD Disable all system features that prevent writing to the hard drive boot sector Insert the HP Server cc3300 amp cc2300 User Information Diag
15. eattececssaidews 11 Installing Intel server Control ISCO sscccaiieseseta estimations ent ideada 12 Managed Server Preparation icceccccces eke diieiot oeededaietaceneteediameeenaideedaeneee eaten eee 12 Compatibility and Upgrade ISSUES cccceeceee cette ee eeeeeeeeeeene eee eeeceeeeeeteeeeeeeeeeiaaeeeeeenaeeeeee 12 LUI RedHat soic te trees beh canst aea aeae late th ce A EA teed OaE aA 12 LANDesk Server Manager LOSM a chia e E E gece cee 12 Windows 2000 Advanced Server ccecccceceeesccceeeeeneceeeeesaaeeeeesnaaeeeeseaeeeseeneeeeeeeeeneeeees 13 ISC Installation Procedure for Windows 2000 Advanced Servet ccccecceeeeeeteeeeeessneeees 13 ISC Installation Procedure for Linux Red Hat 7 1 and Red Hat Enterprise Linux AS 2 1 14 Installing Linux DMI Service Provider oscs tccetei dle Neiessede ance daesctantehd uatehcaceiadded 14 Installing ISC Server InstrUMentation ccceccceeeseeeeeeeeeeeeeeeeeesaeeeeeeeaeeeeeesnaeeeeeeeaees 15 Configuring the SNMP DMI Mappev 2 cccseececeeeeeecceeeeeeeaaeeeeeenaeeeseeeneeeeeeeeaaeeees 16 Launching Intel Server Control ISC sssssssssssssnsnnnnnnnnunuununnunnnnnnnnnnnnnnnnnnnnnnnn 16 Intel Server Control H P Network Node Manager 2 cceeeseecceeeeeseeeeeeenneeeeeeeseeeeeeeeeeaeees 17 LANDesk Server Manager aii jicciencccdcceeeadetccmanvaccibeotyusenmpie ay deed yetetinnanedoeepueeeecentabudiaianielal 17 OEN E EE th Sea cnet EEEE E EE T Ret atid
16. es Resource CD 9 When the menu appears use the arrow keys to select the Utilities menu and press Enter SONANDM PWN Intel Server Control Installation Guide 10 Select Run System Setup Utility under the Utilities menu You will see SSU executables installed the first time and then the Server SSU launches 11 In the Available Tasks list select Platform Event Manager and click OK 12 Click the Configure EMP button 13 Enter the following in the Emergency Management Port EMP dialog box Option Entry Enter New Password Enter the EMP password if required up to 16 characters Verify New Password Re enter the EMP password if required ESC Sequence default Hangup String ATH default Modem Init String ATE1Q0V1X4 amp D0S0 0 default May require change based on the installed modem requirements System Phone Number The phone number to call when using a modem to access the EMP port Access Mode Always Active default is Preboot Restricted Mode Disable default is Enable Connection Mode Modem Connect default for modem connections to COM2 Direct Connect for serial connections to COM2 14 Click Save then Close 15 Exit from the Server SSU 16 Quit the menu 17 Remove the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD from the drive 18 Reboot the server Configuring the Server for LAN Access To take advantage of LAN access and BMC LAN Alert
17. figure Event Actions Enable all paging actions and Save Select Configure LAN Click on Options and select Configure Event Actions Enable all LAN Alerting actions and save Remove the CD and reboot the server 11 Intel Server Control Installation Guide Installing Intel Server Control ISC Managed Server Preparation ISC uses the event logging feature of the BIOS for system management status and information To enable this feature for each server to be managed with ISC you must boot the server s using the System Setup Utility SSU and set the appropriate options under System Management Options Compatibility and Upgrade Issues The following paragraphs describe compatibility and upgrade issues for e Linux Red Hat 7 1 and Red Hat Enterprise Linux AS 2 1 e LANDesk Server Manager LDSM e Windows 2000 Advanced Server Linux Red Hat For installation on systems using Linux Red Hat 7 1 or Red Hat Enterprise Linux AS 2 1 be aware of the following e Remote ISC installation is not available e Additional steps are required to configure the Linux DMI service provider e Additional steps are required to configure the SNMP DMI mapper e ISC with TAM 3 5 3 supports Linux Red Hat 7 1 and Red Hat Enterprise Linux AS 2 1 LANDesk Server Manager LDSM If you have an earlier version of LDSM on your network be aware of the following e The ISC managed server installation will not upgrade the DMI serv
18. gnostics amp Utilities Resource CD into the client s or server s CDROM drive Autorun will launch the CD into the cc2300 cc3300 Welcome screen NOTE The ISC software needs to be loaded onto both the client and the server Installation steps are identical for ISC installation on either the client or the server Click on the Management button at the top of the cc2300 cc3300 Server Welcome screen Click on Server Management Software installer button Run setup exe from the CDROM Click on the Yes button to continue through the Security Warning screen Click OK to Install Upgrade Intel Server Control Click the Next button on the ISC Installation Welcome screen Click Accept on the Intel Software License Screen if you agree with the licensing terms Click Add to select the server for ISC installation Click OK to begin ISC load process Click Next on the Intel Server Control Setup screen Select ISC components for installation Installing Platform Instrumentation Control Intel Direct Platform Control Client SSU and ISC LAN Alert at a minimum is recommended Confirm the computer and the features that will be loaded and click Accept to load ISC ISC installation will begin Click Next on the Intel Server Control Setup screen Message in Intel Server Control Setup screen will say Done Click Close Remove the CD from the CDROM drive and reboot
19. ice provider or any DMI database that is already installed on the managed server However if a service provider is not found ISC installs a DMI 2 0 service provider e The ISC server installation process installs the remote procedure call RPC transports DCE and ONC if they are not available on the managed server e ISC ships with the DMI 2 0s Service Provider for Windows NT The 2 0s version is an extension of the Service Provider that supports security ISC does not use those features but they are available under Windows NT for possible use by other DMI 2 0s compliant software 12 Intel Server Control Installation Guide Windows 2000 Advanced Server Connect as a user with supervisor rights or administrator when installing ISC to a Windows 2000 Advanced server The ISC installation program automatically reboots both remote and local servers as necessary only Windows 2000 Advanced Server can be automatically rebooted ISC Installation Procedure for Windows 2000 Advanced Server The Intel Server Control ISC package contains both the console client and instrumentation server software The console and instrumentation software is installed onto both the client and the server ISC installation will require rebooting both the client and the server 1 14 15 16 17 18 19 Verify that H P Openview is not running and make sure the system is booted Insert the HP Server cc3300 amp cc2300 User Information Dia
20. ll versions of these three packages Note that these names may not be the same for Linux 7 1 rpm i ucd snmp 4 1 1 15smux 1i386 rpm rpm i ucd snmp utils 4 1 1 15smux i386 rpm rpm i dmi2snmp 1 0 15 i386 rpm 6 Reboot the Linux server after you have installed all the packages Installing ISC Server Instrumentation 1 Insert the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD into the Linux server CD ROM drive 2 Mount the CD using either of the following methods e Enter the mount command as follows mount mnt cdrom e Use the Disk Management utility To invoke this utility click the Start button select System and then select the Disk Management menu option 2 List the contents of the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD and make sure the ISC install packages and scripts are on the CD You can locate these packages in the Software Linux directory Use the following commands to move to that directory and list the files cd mnt cdrom Software Linux ls You should see filenames similar to the following ipmidrvr 2 2 14 6 1 1smp 1 1386 rpm ipmidrvr 2 4 2 2smp 1 i1386 rpm isc 3 5 1 1386 rpm installme 15 Intel Server Control Installation Guide 3 Run the ISC install script from the directory you listed in the previous step by entering the following command at the command line prompt installme 4 Follow the ins
21. n ccccccceeeeeeeeeeeeeeeeeeneeeees 5 Console Requirements OVerView ccccccscceeecsseeeeeeeeceaeeeeeesaeeeseeaeeeeeeeeaaaeeeeesaaaeeeeesaaaeeeesaaas 5 Windows 2000 Console Requirement ccccecsceeeeeeseeeeeeeeneeeeeeseeeeeeeeeeeaeeeeeenaeeeees 5 Semice ca Lad O r See Beer Ser Rese ne eee a arP Rn ee erereenn penser Serer 6 Service Partition Installation esena ee iad ed a eee 6 REO EIE A ies sacle noe g aks deena ec senteysas Meth E oaneesethecaseawsen suas eaneceans dbetanis 6 DFAS UMMA ON es cited accents acter ete alethe ar A a te canta ede endian te watteel One alas elon red hte 6 Boot the Server from the Service Partition ceccceeeeeeseeneeeeeeseeeeeeesaaeeeeessaeeeseensaeeeeeeenenees 7 Locally Booting the Server from the Service Partition ceccceseeeeeeeeeeeeeeeeeeeeeeeeeeees 8 Remotely Booting the Server from the Service Partition ccccccceeesesssstteeeeeeeeeeees 8 Configuring the Server for EMP ACCESS cccesccceeeeseeceeeeeesaaeeeseenaeeeseeseeeeeeeeeaaeeeeees 8 Configuring the Server for LAN ACCESS ccccesccceeeeeseceeeeeeceaeeeeeeaeeeeeeeeeaeeeeeeaaeeeeeas 9 Using the Direct Platform Control DPC Console cccccceeeeeceeeeeeeeeeeeeeeseeeeeeteeees 11 Using the Client System Setup Utility CSSU occ recente ee eeeeaeeeeeeeeeeeeeeeaees 11 Enabling LAN BVGIts ccsccccoistencs tc secccetcds cecteciccncnidabeadentdecuesacacecatzinieoss
22. nch ISC CA Unicenter TNG The CA Unicenter TNG Console autodetects servers running the ISC Server Instrumentation software if you have enabled the ISC to CA discovery service To enable discovery you must start the Intel Tng ISC AutoDiscovery service You can start this service from either the TNG Unicenter Auto Discovery dialog or from the Windows NT Services applet The Intel Tng ISC AutoDiscovery service creates a new Intel Server Control TNG object for each server having the ISC Server Instrumentation software That TNG object displays on the map as a child of the ISC World View and as a child of the ISC enabled server You can view all ISC enabled servers under the ISC World View To launch ISC right click on an Intel Server Control icon and select the Launch ISC option from the popup menu ISC Console Use the ISC Console to manage SC enabled servers without installing an enterprise system management console ESMC application To launch the ISC Console 1 Click Start and select Programs 2 Select Intel Server Control and then click on ISC Console 17 Intel Server Control Installation Guide HP Carrier Grade Server Functionality Matrix The following table lists ISC features specific to the HP Carrier Grade cc2300 and cc3300 Servers Table 1 HP Carrier Grade Server Compatibility Matrix
23. nostics amp Utilities Resource CD into the CD drive Restart the server When the F2 to enter setup message appears quickly press F2 to enter Setup In Setup use the arrow keys to select the Boot menu Use the arrow keys to select Boot Device Priority then press Enter Select ATAPI CDROM and use the key to move the selection to the top of the list Press F10 Select Yes to confirm saving of the current settings and press Enter The server restarts and boots from the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD When the menu appears use the arrow keys to select the Utilities menu and press Enter 11 12 13 14 Select Run Service Partition Administrator and press Enter Choose item 3 Create service partition first time Follow the instructions on your screen to select the hard drive for service partition installation The utility creates the service partition and prompts that it will reboot the server when you press any key The server reboots from the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD When the menu appears use the arrow keys to select the Utilities menu and press Enter Select Run Service Partition Administrator and press Enter Choose item 4 Format service partition and install software Follow the instructions on the screen to format the service partition and install the partition software Quit the menu
24. onsider the following issues when configuring SNMP e Community string names for SNMP Get and Set operations e Community string names for sending traps e The destination address for the management console receiving the traps On the management console you should consider the following issues when configuring SNMP e Compiling the MIBs into the SNMP management consoles e Integration of ISC traps into SNMP management consoles Console Requirements Overview ISC Console Software can integrate into an Enterprise System Management Console or it can be installed on a stand alone console The supported Enterprise System Management Consoles are 1 H P OpenViewt Network Node Manager 6 1 for Windows NT 2 Intel LANDesk Server Manager 6 1 1 CA UnicenterTNGT 2 4 for Windows NT Console System requirements may be different when using one of the supported management applications Please refer to their installation requirements for additional information You can use the ISC stand alone console to manage ISC enabled servers without Enterprise System Management The ISC Console is implemented as an ActiveXt control that runs within its own container or a third party container application e g Microsoft Management Console Internet Explorert v5 6 or Netscape Navigatort v6 0 with ActiveX plug in Windows 2000 Console Requirements e Windows 2000 Advanced Server e Intel Pentium microprocessor or higher e At least 64 MB of RAM e Atleast 1
25. s features server settings must be configured using the Server System Setup Utility Server SSU After the settings are initialized they can be changed using the Client System Setup Utility CSSU Use the LAN 1 port for server access If you are going to define a SNMP community be sure to do it before installing ISC 1 Roe Sy SU Re bo Insert the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD into the CD drive Restart the server When the F2 to enter setup message appears quickly press F2 In Setup use the arrow keys to select the Boot menu Use the arrow keys to select Boot Device Priority then press Enter Select ATAPI CDROM and use the key to move the selection to the top of the list Press F10 Select Yes to confirm saving of the current settings and press Enter The server restarts and boots from the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD When the menu appears use the arrow keys to select the Utilities menu and press Enter Intel Server Control Installation Guide 10 Select Run System Setup Utility under the Utilities menu You will see SSU executables installed the first time and then the Server SSU launches 11 In the Available Tasks list select Platform Event Manager and click OK 12 Click the Configure LAN button 13 Enter the following on the BMC LAN Configuration LAN dialog box Option Entr
26. tructions on your screen The script prompts you to read and accept a license agreement Next the ISC install program determines the version of the Red Hat Linux kernel running on your server and installs the right version of the IPMI driver on your server The script then proceeds to install the ISC package e g isc 3 5 1 1386 rpm on your server In case the installation of the driver fails the script displays appropriate error messages and then terminates without installing the ISC package 5 Reboot the Linux server when the command completes Configuring the SNMP DMI Mapper You must complete these steps if any SNMP management console H P OpenView CA UniCenter will manage the Linux server 1 Verify that the dmi2snmp and ucd snmp packages are installed For example the files dmi2snmp 10 15 i386 rpm and ucd snmp 4 1 1 15smux 1386 rpm could represent the dmi2snmp and ucd snmp packages respectively 2 Open the file etc snmp snmpd conf You can use any available editor such as vi emacs or a linux editor 3 Add a trapsink line at the end of the file for each management console that receives traps from the managed server Use the following syntax when adding the line trapsink lt myhost_name domain com gt Be sure to substitute appropriate strings for the host name and domain Launching Intel Server Control ISC ISC can be launched from and can manage your server from one of these enterprise management environments e H P
27. y Enable LAN Alerts Click to enable BMC LAN alerts optional Enter New Password Enter the BMC LAN Configuration password up to 16 characters optional Default is NULL This will be used for all LAN connections in CSSU DPC PIC and BMC LAN alerts Verify New Password Re enter the BMC LAN Configuration password if one is set LAN Access Mode Always Available which allows DPC and CSSU access via LAN By default LAN access is Disabled SNMP Community String Public default unless there is a predefined SNMP host to receive SNMP traps from BMC LAN Alerts Must be from 5 to 16 characters IP Configuration Static default unless you are using DHCP for IP hosting then select DHCP Host IP Address Enter the IP address of the server if you are not using DHCP Gateway IP Address Enter the IP address of the router if you are not using DHCP Subnet Mask Enter the subnet mask of the hosts on the subnet if you are not using DHCP Alert IP Address Enter the IP address of the server to receive SNMP traps for the community defined with the SNMP Community String Enter 0 0 0 0 default if a community is not defined 14 Click Save then Close 15 Exit from the Server SSU 16 Quit the menu 17 Remove the HP Server cc3300 amp cc2300 User Information Diagnostics amp Utilities Resource CD from the drive 18 Reboot the server 10 Intel Server Control Installation Guide Using the Direct Platform Control
Download Pdf Manuals
Related Search
Related Contents
Radio Cassette Player Samsung SGH-U700 Εγχειρίδιο χρήσης ハードウェア取扱説明書 訂正資料 Manual de Instruções - Reset Eletronica Industrial 取扱説明書 - エー・アンド・デイ CTM-700 CTM-700 CTM-700 CTM-700 CTM-700 CTM-700 Severin BA 3220 Scheda Tecnica di Pulsossimetro e GP Batteries Premium Series Powerbank V800C & 4 X 2700 NiMH / AA Copyright © All rights reserved.
Failed to retrieve file