1. for replacements 75190 01 000 03242 07 133 95492 02 000 74508 03 133 2 75184 01 133 x4 84724 01 000 95512 01 02 000 gt gt gt gt gt gt gt gt gt x2 gt Extra coy NOTE Strain relief cable connector 75016 01 000 95011 01 02 000 must be installed Not Included Included Tools Needed Estimated assembly time 30 to 60 minutes Before Installation NOTE Remove all packing materials before installation Turn off the power source 41723 01 12 25 2004 Loosen screws H MoN OSS ed G Pop out the first wiring access slug Use second if needed Insert the strain relief into the housing and secure with the washer Choose Installation Option For New Construction attaching to joist go to step A11 page 5 For New Construction suspended between joists go to step B11 page 8 For Existing Construction accessible from above go to step C11 page 11 For Existing Construction accessible only from below go to step D11 page 15 Remove the pre loaded screw tip covers Back out the pre loaded screw tips until flush with the side of the housing New Construction attaching to joist Remove the wiring cover screw Remove the wiring cover Position the correct depth mark at the bottom edge of
2. the Screw pre loaded screws into joist or framing joist based on the thickness of your sheetrock 41723 01 12 25 2004 41723 01 12 25 2004 Pull wires through the strain relief Connect 4 duct and vent to the outside Tape joints If ducting does not fit securely an adapter may need to be purchased Ground Green Bare Copper a a Fan Motor i Black Main Switch 1 AC In Xs P Night Light s2 Light Red Switch 1 AC In Black Switch 2 AC In Connect wires as shown Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing Install the wiring cover plate Make sure all Tighten the wiring cover plate screw Turn on the power source Test the motor If the motor does not run check the plug wiring connections are inside the box or under connection the wiring cover plate 41723 01 12 25 2004 41723 01 12 25 2004 Go to step on page 18 to attach grille New Construction suspended between joists Mark position of screws by using holes as a template Drill a hole in the center of each outline Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock 41723 01 12 25 2004 Insert screws leaving space between the screw Attach the rails onto the screws head and the
3. Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan If any part of your Hunter bath exhaust fan except for glass fixtures and light bulbs fails at any time within one year after the date of sale to you due to a defect in material or workmanship we will repair or at our option replace the defective part free of charge for parts and labor performed at our nearest service center or at our Service Department in Memphis Tennessee After this one year period you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as provided below If your Hunter bath exhaust fan motor fails at any time within five years after the date of sale to you due to a defect in material or workmanship labor and materials to repair the defect will be provided free of charge at our nearest service center or our Service Department in Memphis Tennessee If no replacement part can be provided we will at our option either refund the actual purchase price of your bath exhaust fan or provide a replacement free of charge After this five year period you will be responsible for all parts and labor costs for repairs on all parts of the bath exhaust fan IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT INCLUD
4. ING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE VOIDED NO WARRANTY EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HUNTER FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH MOTORS OR OTHER PARTS This warranty is voided if your Hunter bath exhaust fan is not purchased and installed in the U S A This warranty excludes and does not cover defects malfunctions or failures of any Hunter bath exhaust fan which were caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling improper installation modifications or damage to the Hunter bath exhaust fan while in your possession or unreasonable use including failure to provide reasonable and necessary maintenance To obtain servicing contact the nearest Hunter authorized service center of the Hunter Fan Company Service Department 2500 Frisco Avenue Memphis Tennessee 38114 Please contact us before shipping your bath exhaust fan to us If we aut
5. and associated wall switch location If you cannot lock the circuit breakers in the off position securely attach a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhaust ing of gasses through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards ACAUTION For general ventilating use only Do not use for ventilat ing hazardous or explosive materials To avoid motor bearing damage and noisy unbalanced impellers keep drywall spray construction dust etc off power unit DO NOT install this product in a wall This product is designed for installation in ceilings up to a 12 12 pitch 45 degrees Ductwork must point upward Please read specification label on product for further information and requirements PREVENTATIVE MAINTENANCE such as those published by the National Fire Prevention Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall s or ceiling do not damage electrical wiring or other hidden utilities 6 Ducted fans must always be vented
6. erly installed p WE Es LT 4 Tp ee SS a E9 gt YE ar gt Q Tighten screws on metal clamps to secure trim assembly Remove the thumbscrews Connect the circline bulb Screw in 1 Max 7 Watt C 7 bulb Not Included 18 41723 01 12 25 2004 41723 01 12 25 2004 19 20 Attach complete trim unit to light base Rotate until secure 41723 01 12 25 2004 Trouble Shooting Problem Fan does not come on Solution e Hunter Fan Bath Ventilators are extremely quiet To confirm that the fan is running place your hand near the vents to feel the air movement e Turn power on replace fuse or reset breaker e Check all plug connections to be sure they are secure e Check the wiring to make sure it matches the wiring diagram Problem Light does not come on Solution e Replace the light bulb with a new bulb e Turn power on replace fuse or reset breaker e Check all plug connections to be sure they are secure e Check the wiring to make sure it matches the wiring diagram Problem Fan is noisy Solution e Check and tighten all fasteners e Check the glass to make sure it is secure e Check the flapper to make sure it moves freely If you need parts or service assistance please call 888 830 1326 or visit us at our WEB site at http www hunterfan com 41723 01 12 25 2004 21
7. he Mark position of screws by using holes as a template Connect 4 duct and vent to the outside Tape joints Pull wires through the strain relief joist based on the thickness of your sheetrock If ducting does not fit securely an adapter may need to be purchased i Tighten the strain relief screws Ground Green Fan Motor Night Light Light Connect wires as shown Install the wiring cover plate Make sure all wiring connections are inside the box or under the wiring cover plate Connect wiring from the motor to the wiring cover plate Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing SD Bare Copper Red Switch 1 AC In Black Switch 2 AC In Tighten the wiring cover plate screw Secure the motor by tightening the 2 screws Turn on the power source C29 Go to step d on page 18 to attach grille Test the motor If the motor does not run check the plug connection Existing Construction accessible only from below EXISTING FAN Remove an existing fan and check to make sure the open Move the housing into position above the ceiling ing is large enough to accommodate the new motor hous ing 9 x 9 75 41723 01 12 25 2004 15 Attach existing ducting to duct connector Tape
8. horize you to ship it to us you will be responsible for all insurance and freight or other transportation charges to our factory or service center We will return your Hunter bath exhaust fan freight prepaid Your Hunter bath exhaust fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Proof of purchase is required when requesting warranty service The purchaser must present the sales receipt or other document that establishes proof of purchase IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE 2500 Frisco Avenue Memphis Tennessee 38114 Printed in China 41723 01 12 25 2004 90066 90067 Millenium Bath Ventilator with Light and Night Light 41723 01 12 25 2004 TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY OBSERVE THE FOLLOWING 1 Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer at the phone number or address listed in the warranty Before installing servicing or cleaning the unit disconnect the power by turning off the circuit breakers to the outlet box
9. joints If ducting does not fit securely an adapter may need to be purchased Pull wires through strain relief Screw pre loaded screws into joist or framing Ground Green Fan Motor Night Light O Light O Red Switch 1 AC In Black Switch 2 AC In Connect wires as shown 16 41723 01 12 25 2004 Install the wiring cover plate Make sure all wiring connections are inside the box or under the wiring cover plate Tighten the wiring cover plate screw Connect wiring from the motor to the wiring cover plate Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing a wW Secure the motor by tightening the 2 screws Turn on the power source 41723 01 12 25 2004 17 D23 Go to step ON Eie 2 OFF on page 18 to attach grille Test the motor If the motor does not run check the plug connection Slide light base over posts in motor housing Attaching the Grille Remove backs from 4 tape strips found on the trim disk Rotate 4 metal clamps over glass trim Attach thumbscrews Insert 1 Max 30 Watt CFL Pin Based Circline bulb Included Press metal trim disk into glass trim ring WARNING To reduce the risk of electrical shock into spring clamps all 4 thumbscrews MUST be prop
10. joist Screws are not provided Night Light 41723 01 12 25 2004 Tighten screws Pull wires through the strain relief Ground AS Green D Bare Copper Black Main Switch 1 AC In iE Po Red Night Light Na A Black Light Red Switch 1 AC In Black Switch 2 AC In Connect wires as shown Install the wiring cover plate Make sure all wiring connections are inside the box or under the wiring cover plate Connect 4 duct and vent to the outside Tape joints If ducting does not fit securely an adapter may need to be purchased A wA DO gt 1 Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing Secure the motor by tightening the 2 screws 10 41723 01 12 25 2004 Test the motor If the motor does not run check the plug Turn on the power source connection Go to step on page 18 to attach grille Existing Construction accessible from above EXISTING FAN NO EXISTING FAN x Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing 9 x 9 75 Use the motor housing as a template to mark position 41723 01 12 25 2004 11 Attach the rails onto the screws Position the correct depth mark at the bottom edge of t
11. to the outdoors Keep ducting as short and as straight as possible 7 Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit 8 Install fan at least 5 feet 1 52 m above the floor 9 Never place a switch where it can be reached from a tub or shower 10 This unit must be grounded AWARNING DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT A clean fan provides better service Disconnect the power supply and clean the fan as listed below TO CLEAN GRILLE Use a mild detergent such as dishwashing liquid and a soft cloth DO NOT use abrasive cloths steel wool pads or scouring powders TO CLEAN FAN ASSEMBLY Unplug motor cord from receptacle To remove motor plate find the single tab on the motor plate located next to the receptacle Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing next to tab and twist screwdriver Gently vacuum fan motor and interior of housing METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER MAINTENANCE The motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the motor with the exact service motor You should replace the impeller at the same time 41723 01 12 25 2004 95044 01 000 Check all the parts If damaged call 1 888 830 1326 95022 01 000