Home
Honeywell DR4300 DVR User Manual
Contents
1. of conditioning the fresh outside air that is brought into your home This increases the temperature of the fresh air brought inside in the winter and cools the fresh air brought inside in the summer In addition for ER150 and ER200 models moisture is transferred from the wet side to the dryer side The core removes easily for cleaning 5b Heat Transfer Core As the exhaust and fresh air pass through opposite sides of the Heat Transfer Core heat is transferred from the warm side to the cold side This heat transfer reduces the cost of conditioning the fresh outside air that is brought into your home This increases the temperature of the fresh air brought inside in the winter and cools the fresh air brought inside in the summer The core removes easily for cleaning Operating your Fresh Air Ventilation System Changing Fan Speed Depending on the control installed with your ERV you might be able to change the fan speed Check the manual of your control for more information Connecting a Remote Device Your ventilator comes equipped with a low voltage terminal strip for connection to several optional control devices EXTERNAL REMOTE WALL CONTROL DEHUMIDISTAT The dehumidistat connected to your ventilator is designed to control the operation of the ventilator fan to help keep the humidity level in your home comfortable If an independent humidifier is installed and set at 30 a normal indoor winter level then the dehumidistat for the ve
2. remove them from the core NOTE The core is designed to appear to protrude from the cabinet approximately 1 8 in 3mm so the access door fits tightly against the core 7 69 1188 03 DRAIN LINE SOME MODELS Clean the drain line once a year 1 Inspect the drain line drain spout and P trap for blockage mold or kinks 2 Flush with warm soapy water and replace if worn or bent or if it can not be cleaned DEFROST PORT NON DUCTED DEFROST DAMPER MOTOR AND DOOR CORE INSTRUCTIONS ENERGY TRANSFER FILTERS CORE L 2 CABINET LM mms DUCTING O 4 PORTS gt O t _ MAIN H MOTOR 4 y 57 SQUIRREL Sy CAGE FAN AS CORE GUIDE CHANNEL 4 no a e Poo EP DRAIN PANS DRAIN P TRAP INSULATED A ACCESS DOOR XL poor Soman KERER LINE M29852 GENERAL MAINTENANCE Twice a year wipe the inside of the cabinet with a damp cloth to remove dirt bugs and debris that can be present FANS If the fans accumulate dirt it could cause an imbalance and excessive vibration of the ventilator A reduction in air flow can also occur In a newly constructed house this often happens within the first year due to heavy dust residue in the entire system It can also occur periodically depending on the outdoor conditions If you suspect that service is required please contact the ventilator installer or your local HVAC contractor 69 1188 03 Troub
3. 3 10 11 69 1188 03 Automation and Control Solutions Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited Honeywell Limit e Honeywell 35 Dynamic Drive n U S Registered Trademark Toronto Ontario M1V 4Z9 2010 Honeywell International Inc 69 1188 03 M S Rev 01 10 yourhome honeywell com Printed in U S A
4. Honeywell ER150 ER200 HR150 HR200 Perfect Window Fresh Air Ventilation Systems OWNER S MANUAL M11706 69 1188 03 TABLE OF CONTENTS Introductions ove A A A eS RA fae 3 Feeling right at home cout e ce oo BE Pd ea o id 3 The Perfect Window Fresh Air Ventilation System consists 0f 3 Operating your Fresh Air Ventilation System 0 0 0 0 eee eee ee 5 Getting the most from your Fresh Air Ventilation System 6 Maintenance Instructions for your Fresh Air Ventilation System 6 Troubleshooting s s siian te en tee 9 Limited Warranty oia a EA a eee eek 10 69 1188 03 Introduction We take it for granted that our homes will protect us from the elements but because of tighter energy efficient home construction our indoor environment may be exposing us to unacceptable levels of the very things we are trying to escape Excessive heat dryness humidity toxic gases and dust contaminants can be sealed in securely by weatherproofing Feeling right at home Unlike what the outdoors brings us you can have control of indoor conditions Temperature humidity levels and air quality can all affect physical health mental attitude general comfort and energy savings With today s technological advances you can achieve a Perfect Climate indoors The Honeywell Perfect Window Fresh Air Ventilation System removes stale unhealthy air and replaces it with a st
5. leshooting Lack of power to the ventilator e Power failure of electrical box Loose or unplugged power cord Faulty breaker or fuse in home s electrical panel Call your installation contractor Power to the ventilator but no fan operation e Ventilator is in standby mode and optional remote dehumidistat is set to OFF or the humidity setting is higher than room humidity Door is not closed properly the safety interlock switch will keep the ventilator off Check that the access door is firmly closed and latched e Refer to operating instructions Call your installation contractor for service 9 69 1188 03 Limited Warranty Honeywell warrants this product to be free from defects in the workmanship or materials under normal use and service for a period of one 1 year from the date of purchase by the consumer If at any time during the warranty period the product is defective or malfunctions Honeywell shall repair or replace it at Honeywell s option within a reasonable period of time If the product is defective i return it with a bill of sale or other dated proof of purchase to the retailer from which you purchased it or ii package it carefully along with proof of purchase including date of purchase and a short description of the malfunction and mail it postage prepaid to the following address Honeywell Return Goods Dock 4 MN10 3860 1985 Douglas Drive North Golden Valley MN 55422 This war
6. ntilator should be set at least 10 higher in this case 40 With the ventilator operating on low speed and no one at home to produce humidity the humidifier will keep the humidity level at its setpoint If the humidity levels rise due to occupant activity above the 40 level then the dehumidistat will automatically increase the speed of the ventilator fan to high until the humidity level falls below 40 NOTE During the winter months the air inside your home usually contains more moisture than the outside air even though the outside relative humidity is higher than the inside relative humidity The ventilator will automatically turn off the dehumidistat feature during the summer months when the outside air contains more moisture than the inside air TIMER For your convenience Honeywell provides an optional timer control that can fit a wide variety of needs for example exhaust humid air from the bathroom or kitchen see the timer instructions for selection and part numbers 5 69 1188 03 WALL SWITCH A wall switch can also be used to switch your ventilator fan speed to high The fan will run at high speed until the wall switch is turned off The remote device can be wired to run the ventilator at either the high or low speed Getting the most from your Fresh Air Ventilation System HOW MUCH VENTILATION DO NEED During the seasons that your windows and doors are closed winter and summer if you have air conditioning the ven
7. ranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state If you have any questions concerning this warranty please write Honeywell Customer Relations 1985 Douglas Dr N MN10 1461 Golden Valley MN 55422 In Canada write Honeywell Limited Honeywell Limit e 35 Dynamic Dr ON15 Toronto Ontario M1V 429 69 1188 0
8. ream of fresh air Its powerful centrifugal blowers bring fresh air into your home and at the same time exhaust stale air in an equal amount Both incoming and outgoing airstreams pass through either a heat transfer core or an energy transfer core where the heat only or the heat and the moisture from the exhaust air are efficiently transferred to the incoming fresh air An air duct system supplies the fresh air brought in by the Perfect Window ventilator and distributes it throughout your home Another duct draws the existing stale air back to the Perfect Window ventilator and then exhausts it outdoors It s really very simple and remarkably effective The Perfect Window Fresh Air Ventilation System consists of 1 Air Circulation FAN and Motor Inside the casing are two fans one for exhaust and one for fresh air supply The electric motor that operates the fan is 1 15 hp to 1 20 hp depending on the ven tilator model and uses the same amount of power as a 100 watt light bulb 2 Air Filters There are two permanent washable air filters in your ventilator The filters lower the amount of dust and outside particulates entering the ventilator core and your fresh air supply 3 69 1188 03 3 Condensate Tray and Drain Some Models Condensation normally forms on the energy transfer core during the cold weather below 27 F or 3 C Moisture can build up when the warm air from your home comes in contact with the cold air from ou
9. rost has not built up on the wire mesh bird screen 69 1188 03 6 FILTER CLIP Y FILTER CORE GUIDE CHANNEL M29786 A WARNING Carbon Monoxide Hazard Can cause personal injury or equipment damage Hood blockage can cause a change of pressure in building which can lead to possible spillage from combustible appliances CLEANING FILTERS AND CORE Air filters should be cleaned twice a year The standard filters supplied with your ventilator are removable and washable Core should be cleaned twice each year 1 2 3 4a 4b Open ventilator door by loosening draw latches on top of unit and swinging door open For easier access remove door by moving it right to disengage hinges Carefully grip ends of core be careful not to damage the aluminum fins then pull evenly outward Core fits tightly but slides out of channels Once core is removed filters can be removed by detaching the clips holding them in place Note clip installation for reassembly ERV core Vacuum the ERV core or rinse with cold water Do not use soap dish washer or a pressure washer HRV core Soak and rinse the HRV core in warm soapy water Do not use clean ing solutions Wash the filters in warm soapy water Place the clean filter wet or dry over the core and secure it in place with the clips Reinstall core by sliding it into the four corner channels Water cannot damage gasket and label on core ends so it is not necessary to
10. tilator should operate continuously when the home is occupied and either continuously or intermittently when not occupied For most installations the ventilator will normally be set to operate continuously on low speed with the option of going to high speed as the need arises For example if you are entertaining and there is a large number of people present some may be smoking the ventilator should be switched to high speed YOUR VENTILATOR MAY BE SET TO HIGH SPEED if the system includes an optional remote control switch it to the ON position NOTE To set an optional dehumidistat refer to the previous section of this booklet To operate other remote devices refer to the device owner s manual Maintenance Instructions for your Fresh Air Ventilation System Ah WARNING Electrical Shock Hazard Can cause personal injury or equipment damage Disconnect power supply before performing maintenance The Perfect Window Fresh Air Ventilation System must be maintained on a regular basis for best efficiency Honeywell recommends that the ventilator be cleaned and checked at least twice a year preferably at the beginning of each heating and cooling season Check and Clean EXTERIOR HOODS Exterior hoods should be inspected at least once a month Be sure exhaust and fresh air supply hoods are not blocked up or restricted by leaves grass or snow In winter it is especially important to make sure snow is not blocking the hoods or that f
11. tside The tray collects the moisture and funnels it to the drain The drain pans are made of thermoformed plastic for easy cleaning 4 Defrost Mechanism Some Models Some models have an electronically controlled damper frost control mechanism to prevent frost buildup on the core Defrost timing will change based on incom ing outdoor air temperature Outdoor Temperature Defrost Timer 27 F 370 3 minute defrost 25 minute run 4 F 20 C 4 5 minute defrost 17 minute run 31 F 35 C 7 minute defrost 15 minute run Example When the outside temperature drops below 27 F 3 C the defrost timer is activated At the end of the 25 minute run cycle when the core can experience some nominal frost buildup the timer activates a motor driven damper door that simultaneously opens the defrost port and closes off the supply air port DEFROST PORT NON DUCTED DEFROST DAMPER MOTOR AND DOOR CORE INSTRUCTIONS ENERGY TRANSFER CORE CABINET FILTERS DUCTING 4 PORTS _ _ MAIN H MOTOR T SQUIRREL A N CAGE FAN a e oa ea ma CORE GUIDE y 7 CHANNEL 4 A Pd A sap y oe DRAIN PANS DRAIN P TRAP INSULATED s ACCESS DOOR XL poor Mpman KEEFE LINE M29852 69 1188 03 4 5a Energy Transfer Core As the exhaust and fresh air pass through opposite sides of the Energy Transfer Core heat is transferred from the warm side to the cold side This heat transfer reduces the cost
Download Pdf Manuals
Related Search
Related Contents
1MA268_e_IVINET_Drivers Toshiba Satellite S75D-A7272 Fujitsu T4210 Laptop User Manual ENH210 User Manual - EnGenius Technologies, Inc. HawkEye Pro User Manual Annales droit luxembourgeois Construcción - Tierra Mia CA Philips AVENT SCD234/01 User's Manual INSTALLATION AND SERVICING Copyright © All rights reserved.