Home
Honeywell 18150 Series Air Cleaner User Manual
Contents
1. Honeywell Portable HEPA Air Cleaner READ AND SAVE THESE INSTRUCTIONS Install Pre filter Before Initial Use Owner s Manual For Model 18150 Series Air Cleaners The Science of Clean Air Important Safety Instructions PLEASE READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR CLEANER When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Read all instructions before operating the air cleaner 2 Place air cleaner where it is not easily knocked over by persons in the household 3 Always turn the air cleaner to the OFF position and unplug when not in use 4 To disconnect the air cleaner first turn the air cleaner to OFF position grip the plug and pull it from the outlet Never pull by the cord 5 Do not use any product with a damaged cord or plug or if product malfunctions is dropped or damaged in any manner Keep the cord away from heated surfaces 6 Do not use air cleaner outdoors 7 Never use air cleaner unless it is fully assembled 8 Do not run power cord under carpets and do not cover with throw rugs Arrange cord such that it will not be tripped over 9 Do not use air cleaner where combustible gases or vapors are present 10 Do not expose the air cleaner to rain or use near water in a bathroom laundry area or other damp location 11 The air c
2. its side 2 Push in on both tabs on base ring to release base per diagram 3 Gently remove base from motor assembly Fusti 4 Install initial pre filter or replace used one Wrap pre both tabs filter around Base Ring and attach with fastener to release provided Base Ring 5 Align base into grooves and gently snap back into place Troubleshooting Important this air cleaner has been designed to operate very quietly and effectively without a cool exhaust draft especially on lower speeds e Start on HIGH for a few minutes then adjust to desired speed e This product may emit a new smell which will disappear over a relatively short period of operation e Check to make sure that the power cord is correctly connected to the outlet e Test that the outlet is functioning properly using another appliance or lamp e Check the fuse or circuit breaker The outlet may be overloaded if other appliances are also in use Determine and correct the cause of the overload e f none of the above procedures restore operation return your unit to the store If the store s return policy does not allow the return return the complete unit per the instructions in the warranty section of this owner s guide Do not attempt to repair the unit yourself as it may cause injury and the warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in accordance with this manual 5 Year Limited Wa
3. to the place of purchase in accordance with store policy or to Honeywell C This warranty does not cover damage resulting from unauthorized 2000 Honeywell All Rights Reserved AC7020 00 attempts to repair or from any use not in accordance with this manual D This warranty DOES NOT cover the pre filter or the HEPA filter except for material or workmanship defects E Return defective product to the following address with a brief description of the problem Include proof of purchase and a U S 10 00 Canadian 15 00 check or money order for handling return packing and shipping charges Please include your name address and daytime phone number You must prepay shipping charges Mark carton Attention Returns Department Ship to In USA Honeywell Returns Department 4755 Southpoint Drive Memphis TN 38118 U S A In Canada Honeywell 510 Bronte St South Milton Ontario Canada LOT 2X6 If you experience a problem with your Air Cleaner please see owner s guide for instructions Please do not attempt to repair the air cleaner yourself Doing so may void the warranty and could cause damage or personal injury If the problem still persists please call Honeywell Consumer Relations Dept service honeywell com Toll Free 1 800 332 1110 Mail Questions or Comments to Honeywell Consumer Relations Dept 250 Turnpike Road Southborough MA 01772 U S A Visit our website at www honeywell com yourhome 035 004
4. 0 series air cleaner has been designed to operate very quietly and effectively without a cool exhaust draft To operate press the POWER button to HIGH speed for a few seconds and then leave it on high for faster more powerful air circulation or move it to a lower setting as desired Intelli Check Filter Monitors This air cleaner is equipped with Intelli Check Filter Monitors to serve as a convenient guideline for replacement of the pre filter and HEPA filter based on the air cleaner s hours of use and operating speed This is beneficial because a filter s life depends on the amount of air and contaminants drawn through it The monitors have the ability to indicate the amount of expected filter life used Once a filter has reached the end of its expected life its light will remain on until it is RESET You may unplug the air cleaner without interrupting the filter monitors The Intelli Check Filter Monitors count the expected filter life based on an assumed average operating time of 12 hours a day on medium speed Therefore it will indicate replacement of the Pre filter in about 3 months and the HEPA filter in about 1 year and 9 months Depending upon your individual usage environment hours and speed of operation you may need to check and replace the filters more or less frequently To CHECK Expected Filter Life Usage When the unit is turned on quickly press the filter monitor button The pre filter light will flash up
5. 06 000 Rev 0
6. at you operate your Honeywell air cleaner 24 hours a day because indoor air can be quickly contaminated by activity in a room infiltration of outside air and from sources of contamination While all the air in a room will not be processed by the air cleaner the more air circulated through the filter the more filtered air returned to the room Portable air cleaners will be much more effective in rooms where all doors and windows are closed It can be placed on the floor in almost any location However for best performance the air outlet slot should not be blocked for at least 3 feet 1 meter in all directions NOTE Due to the large volume of air drawn towards the air cleaner surrounding areas should be cleaned and or vacuumed frequently to prevent build up If the unit is placed on light colored carpeting a small mat or rug should be used to ease cleaning and prevent permanent staining This is particularly important in homes with heavy contamination from smoking or fireplaces Construction Handle ES KJ SD Top Cover QS nana ee HEPA Filter CONTROL PANEL HEPA Filter check reset monitor Pre filter check reset monitor Power Button OFF HIGH MED LOW Pre filter Base Ring INSTALL PRE FILTER BEFORE INITIAL OPERATION Refer to How to Install and Replace Filters section for proper installation To encourage operation on higher speeds the Honeywell 1815
7. ge the filters With proper maintenance your Honeywell air cleaner is designed to provide years of high efficiency air cleaning Our recommendations regarding filter replacement intervals are intended as guidelines only as life expectancy of any filter media is dependent on the concentration of the contaminants to which the system is exposed If there are sources of large amounts of contaminant generation such as dust from woodworking or heavy smoking the useful life of the filter media in your air cleaner may be reduced and require early replacement The primary HEPA filter should remain effective for 1 to 3 years depending upon the environment in which the air cleaner is operating Honeywell recommends changing the HEPA filter based upon operation conditions every 3 years for light usage 2 years for normal usage and 1 year for heavy usage The activated carbon pre filter helps protect the HEPA filter by capturing lint and other large particles and helps reduce normal household odors It should be checked monthly and replaced at least every 3 months If there are heavy concentrations of odors smoke or large particles in the home you may need to change the pre tilter more often We DO NOT recommend operating the air cleaner without the activated carbon pre filter or without following the filter replacement guidelines Whenever the air resistance of the HEPA filter becomes excessive due to the amount of contaminants it has captured the a
8. ir volume output will begin to reduce and the sound level of the air cleaner will increase If you store your Honeywell HEPA air cleaner for more than 30 days we recommend e Removing both the primary HEPA filter and the activated carbon pre filter from the unit e Discarding the pre filter e Wrapping the HEPA filter in an air tight plastic bag or plastic wrap Be sure that the filter is totally sealed To restore the air cleaner to service unwrap the HEPA filter install a new activated carbon pre filter and reinstall both filters in the air cleaner See How to Install and Replace the Filters section for proper installation How to Install and Replace the INSTALL PRE FILTER BEFORE INITIAL OPERATION The initial pre filter is packaged separately to ensure its freshness BEFORE initial operation locate the pre filter in the box remove it from its packaging and install per instructions below 1 DISCONNECT FROM POWER SUPPLY BEFORE Open Close SERVICING Handle gt Handle 2 Replace filter s and re assemble unit per instructions below 3 Plug in and RESET appropriate filter monitor s HETA i ll ilter To Replace HEPA Filter 1 Unscrew handle counter clockwise 2 Remove top cover Pre filter 3 Replace HEPA Filter there is no top or bottom to filter installed on E Base Ring 4 Replace top cover 5 Insert and tighten handle clockwise To Replace Pre filter 1 Place unit on
9. leaner must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air cleaner Do not block air outlets or intakes 13 Locate air cleaner near power outlet and avoid using an extension cord 14 This appliance has a polarized plug one blade is wider than the other To reduce risk of shock this plug is intended to fit only one way in a polarized outlet If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to defeat this safety feature 15 A loose fit between the plug and the AC outlet receptacle may cause overheating and a distortion of the plug Contact a qualified electrician to replace loose or worn outlet 16 Do not sit stand or place heavy objects on the air cleaner 17 Disconnect power supply before servicing WARNING To reduce risk of fire or electric shock do not use this product with any solid state speed control device Congratulations You now own a quality portable HEPA air cleaner that has been engineered and crafted for your satisfaction Our Consumer Relations representatives will be pleased to help with any questions or concerns you may have about your Honeywell air cleaner Please call our Consumer Relations Dept at 800 332 1110 for assistance or email us at service honeywell com For Best Performance We recommend th
10. rranty Honeywell HEPA Air Cleaners Model No 18150 Series This product has been engineered and crafted with great care for your satisfaction Be sure to fill out and return the enclosed card within 10 days of purchase A This limited warranty applies to repair or replacement of product found to be defective in material or workmanship within 5 years of the date of purchase This warranty does not apply to damage resulting from commercial abusive unreasonable use or supplemental damage Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty HONEYWELL IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE ANY IMPLIED WARRANTY INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS LIMITED WARRANTY Some regions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from region to region This warranty applies only to the original Purchaser of this product B At its option Honeywell will repair or replace this product if it is found to be defective in material or workmanship within the limited warranty period Defective product should be returned
11. to 3 times and the HEPA filter light will flash up to 4 times depending upon how much expected filter life has been used PREFILTER 1 flash from new up to 1 3 expected life used up 2 flashes between 1 3 and 2 3 expected life used up 3 flashes between 2 3 and all of expected life used up Remains on time to replace pre filter HEPA FILTER 1 flash from new up to 1 4 expected life used up 2 flashes between 1 4 and 1 2 expected life used up 3 flashes between 1 2 and 3 4 expected life used up 4 flashes between 3 4 and all of expected life used up Remains on time to replace HEPA filter To RESET Filter Monitor When the filter monitor light remains on it is time to replace the filter and reset the filter monitor With the unit powered on press and hold the filter monitor button down for approximately 5 seconds until the light turns off Replacement Filters Model HEPA Filter Carbon Pre filter Number Series Part Number Part Number 18150 21500 38002 contains 8 replacements Replacement filters may be purchased from the retail store where you purchased the product If you cannot locate one in your area please call our Consumer Relations Dept at 800 332 1110 for assistance email us at service honeywell com or visit us at www honeywell com yourhome Filter Replacement Intervals CAUTION Do not attempt to wash either the activated carbon pre filter or the HEPA filter They are not washable and washing will dama
Download Pdf Manuals
Related Search
Related Contents
TURNSTILES T2500D DOUBLE TRIPOD ELECTROMECHANICAL 1x - Ergotron Multilingual Version English Español 中文 Italiano Français 日本語 施工説明書番号 岡 F-700 Operation and Installation Manual Ball Valves 55PTHD… Copyright © All rights reserved.
Failed to retrieve file