Hobart HBR300 Scale User Manual

image

Contents

1. 14 000 N 1 250 READ WIDTH 1 250 TREAD WIDTH SIDE VIEW REAR VIEW 18 F 34220 Rev A 2 99
2. HBR300 Bench Receiving Scale Instruction Manual CORPORATION 701 S RIDGE AVENUE TROY OHIO 45374 F 34220 Rev A 2 99 Bench Receiving Scale Table of Contents INTRODUCTION 1 BCC NOIe us oboe eoe tee REN PETER ot oed e 1 Verify Cofrectness Of Weight A a 1 Installation and Setup by An Authorized Hobart Technician 2 Manual Overview ioco eem Deinen la it 2 USING THE SCALE Hasena o n 3 oupplyine Power tothe sense 4 Leveling the Scale ni Bee Renee nn 5 Adjusting the Display Head tor Easy Viewing a 5 DISPLAY HEADS ns see 6 icy DE ERST 6 eo atate ee 7 isses 7 Setup Mode Istri Meneses Melee Mo io titio Ns 8 OPERATING THE SCALE oisi chante gerne 9 Operating in Setup Mode HU RH Gd ru e e dete 9 Presetting Tare sese nn nnn nnn nnn nennen nennen nnn 9 Clearing a Preset laredo daa 11 Setting Upper and Lower Weight Lima En 11 Clearing Upper and Lower Weight Limits zus redeem tt Toten eere etie denen 13 Operating in Operator Mode iii ede tete eet Re nha De cine SE IER Ee dei ee bro 14 Weighing Product Using One Touch Late uu isst tpe lee en 14 Weighing a Product When Preset Tare ee 14 Weighing a Product When Upper and Lower Weight Limits Are 14 Weishins im Bale Dion esse ebene 15 CLEANING AND MAINTAINING
3. Display Head S Platter Fun Legs Guidelines for using your scale DO e Set the scale in an area free of vibration e Set the scale on a firm level surface e Operate in temperatures between 5 C and 40 C 23 F and 104 F e Use soap and water solution to clean the scale e Use four 4 D cell batteries to power the scale DON T e Use solvents or abrasive materials to clean the scale Place the scale in direct sunlight or direct wind heating ducts etc Bench Receiving Scale Supplying Power to Power can be supplied to the scale through the AC adapter the Scale or optional batteries The scale uses four 4 D cell batteries not supplied by Hobart To insert batteries 1 Open the front cover of the display by pulling the tab located on the back right side of the display toward you Mating Terminal 2 Insert batteries using the imprinted diagram inside the battery case located on the inside front cover of the display head To use the power supply 1 Connect the wall mount adapter plug to a 120 V 60 Hz 1 Ph electrical outlet 2 Connect the small round 12V DC connector to the Mating Terminal located on the left lower back corner of the display head EE When the scale is turned ON all segments of the display flash approximately 5 times Then zero displays and the following indicators illuminate e Zero e Stable e kg OR Ib e Gross Wt Bench Rece
4. Scale Operating the Scale Refer to the specific section for a further explanation of each step Operating in Setup Mode Presetting Tare To operate the scale 1 PRESS far to turn the scale on 2 Access Setup Mode to preset tare and set upper and lower limits if desired 3 Access Operator Mode to operate one touch tare weigh products and weigh items in batches REFER to page 14 4 Access Setup Mode to clear or change preset tare or upper and lower weight limits if desired 5 PRESS to turn the scale off Tip Upper and lower weight limits remain in memory unless batteries are removed or cord is unplugged If at any time an incorrect weight displays verify that your desired unit of weight Ib or kg indicator is lit PRESS to change the unit of weight Access Setup Mode to set clear or change preset tare and upper and lower weight limits Preset the tare if you know the package weight tare value If you want to preset tare but do not know the tare value weigh the package or container The weight displayed is the tare value Follow the steps below to preset tare To preset tare 1 HOLD DOWN and PRESS gt The tare indicator and last digit on the display flashes Bench Receiving Scale 7 When setting the tare value only the flashing digit can be changed 2 PRESS to increase flashing digit by one OR PRESS U v to decrease the flashing digit by one 3 PR
5. illuminates if the product weight is over or under your set weight limits The Accept indicator illuminates if the weight is within the set weight limits Once the weight limits are set 1 Place the product on the platter The weight of the product displays and the Over Under or Accept indicator illuminates 2 If the Over indicator illuminates remove some of your product until the Accept indicator illuminates 3 If the Under indicator illuminates add some of your product until the Accept indicator illuminates 14 Bench Receiving Scale Weighing in Batches Weighing in batches allows you to add ingredients and return the weight back to zero repeatedly by pressing Tare to control the weight of each added ingredient type To batch 1 Place the container on the scale platter The container weight displays TARE 2 PRESS to make the display show 0 0 3 Add the ingredient until the desired portion displays as the weight 4 Repeat steps 2 and 3 for each ingredient you wish to add 5 When done remove the container filled with your ingredients from the scale platter The total negative tare weight container and ingredients displays TARE 6 PRESS to clear tare value When weighing in batches PRESS U at any time to display the total weight of the items Press again to return to the weight of the individual item Cleaning and Proper cleaning and maintenance prolongs the life and Maintaining
6. ESS to move left one digit The digit to the left flashes and you can increase or decrease the digit value 4 Repeat step 3 until your tare value is set 5 PRESS to return to Operator Mode Your preset tare value displays EXAMPLE Mixer Bowl Tare 8 7 lb 1 HOLD DOWN and PRESS Em Empty 20 quart Mixer Bowl 10 Bench Receiving Scale Clearing a Preset Tare To clear a preset tare 1 Remove product and container from scale platter The preset tare weight displays 2 HOLD DOWN and PRESS Em The tare indicator and last digit flashes 3 PRESS W The set tare value clears 0 0 displays and the tare indicator and last digit flashes 4 PRESS to return to Operator Mode Setting Upper and Lower If you want the product to weigh a certain amount you can Weight Limits set upper and lower limits By setting the upper and lower limits you indicate the maximum and minimum amount that you want the product to weigh on the scale The Over indicator flashes while in the upper limit setting mode The Under indicator flashes while in the lower limit setting mode Tip gt Ifthe upper limit is set to zero 0 0 The over under mode will not work gt Ifthe upper limit is set to a smaller value than the lower limit an error message E displays Refer to ERROR MESSAGES To set weight limits 1 PRESS to set the lower limit The Under indicator and the last digit on the display flas
7. THE 15 Cleaning iN eie due teste eee ated ii aere far dE 15 Salieron anilla iia 16 Mad EE 16 ERROR MESSAGES 00d A ios 17 ACCESSORY Mobile Carl eee les I ee 18 O Copyright Hobart Corporation 1999 Bench Receiving Scale Hobart Bench Receiving Scale HBR300 SAVE THESE INSTRUCTIONS Introduction The HBR300 Bench Receiving Scale features a digital display with a 6 button keypad which tilts to create the best viewing angle The scale also has adjustable legs and a level indicator to insure proper weight balance is maintained You can operate the scale in four modes using the 6 button keypad on the display 1 One Touch Tare 2 Batch Weighing 3 Preset Tare 4 Upper and Lower Weight Limit This is a digital display scale with a 20 x 16 stainless steel platter which holds a capacity of 300 lb x 0 11b 150 kg x 0 05 kg FCC Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is like
8. es PRESS vera The preset upper limit displays and the Over indicator and last digit flashes ZERO 9 4 PRESS to clear the upper limit 0 0 displays and the Over indicator and last digit flashes 5 PRESS to return to Operator Mode 13 Bench Receiving Scale Operating in Operator Mode Weighing a Product Using One Touch Tare Weighing a Product When Preset Tare is Set Weighing a Product When Upper and Lower Weight Limits Are Set Access Operator Mode to operate one touch tare weigh products and weigh items in batches If you do not know the package weight tare value use one touch tare To operate one touch tare 1 Place the container on the platter The weight of the container displays 2 PRESS ES The display changes to 0 0 and the tare indicator is lit 3 Place the product in the container on the platter The display will indicate the net weight 4 Remove the container and the product from the platter The negative weight of the container tare displays 5 PRESS The weight display changes to 0 0 and the tare indicator no longer illuminates When weighing the product in Preset Tare Mode the weight of the product net weight displays Once the tare is preset 1 Place the container on the platter 0 0 displays 2 Place the product on the platter The net weight displays When weighing a product in Upper and Lower Weight Limit Mode the Over or Under indicator
9. hes To set the upper limit only PRESS again now The Over indicator and the last digit on the display flashes Go to step 6 When setting the upper and lower limit values only the flashing digit can be changed 11 Bench Receiving Scale 2 PRESS to increase flashing digit by one OR PRESS to decrease the flashing digit by one 3 PRESS C to move left one digit The digit to the left flashes and you can increase or decrease the digit value 4 Repeat step 3 until your limit value is set FUNCTION 5 PRESS You are now in the upper limit setting mode The Over indicator and the last digit on the display flashes FUNCTION If you want to set the lower limit only PRESS again now to access Operator Mode 6 Set your upper limit Repeat steps 2 thru 4 7 PRESS to return to Operator Mode EXAMPLE Lower Limit 18 4 Upper Limit 20 0 FUNCTION 1 PRESS HOBART 0 kg b Net Gross 2 PRESS 4 times gt o Over Accept Under Over Accept Under 12 Bench Receiving Scale Clearing Upper and Lower Weight Limits 5 PRESS rr o i 7 PRESS rr ud Over Accept Under To clear weight limits 1 PRESS vera The preset lower limit displays and the Under indicator and last digit flashes 2 PRESS VJ to clear the lower limit 0 0 displays and the Under indicator and last digit flash
10. iving Scale Leveling the Scale There are four 4 leveling legs underneath the scale platter You may need to adjust these legs if the scale is not seated properly Proper adjustment of these legs helps you to maintain the proper scale balance Level the scale by turning the leveling legs right or left until the bubble in the leveling indicator is centered Leveling Indicator Leveling Leg Adjusting the Display To e head N Head for Easy Viewing 1 Push and hold in button located on the back right side of the Display Head 2 Move the Display Head up or down to your desired position 3 Release button Display Head will remain in set position Display Head Adjustment Button Bench Receiving Scale keypad Display Weight displays in Ib pounds or kg kilograms and indicator arrows illuminate on the display Display Head The Display Head can be adjusted for easy viewing and includes the display display indicators and a 6 button TARE Indicator Illuminated Arrow Indicates ZERO No weight is on platter 0e Tare value weight of container displays Stable Indicator Scale is not in motion Unit of weight displays in kilograms Unit of weight displays in pounds The weight of the product only gross weight tare displays Weight is under the programmed lower limit setting Weight is within the range of the programmed weight limits Weight is over the programmed upper li
11. ly to cause harmful interference in which case the user will be required to correct the interference at his own expense Verify Correctness of When calibrated and sealed by your local Weights and Weight Measures official this scale is Legal for Trade The NTEP National Type Evaluation Program certificate of Conformance number is 99 003 Bench Receiving Scale Installation and Setup by an Authorized Hobart Technician Manual Overview Before using your scale for the first time an Authorized Hobart Service Technician must install and set up your scale This includes Mounting the display and display pole to the platform e Setting an automatic shut off time as an energy saver to extend battery life e Calibrating your scale The following special instructions are used in the manual A note is information that you need to know but it is not an actual step in the procedures eooo A tip is additional information that may be useful when you are using the system Look At This Look At This is information to alert you that you may be doing something that will permanently alter your system Bench Receiving Scale Using the Scale When you are ready to use you scale do the following e Supply power to your scale either by battery 4 D cell or a wall mounted adapter plug e Level the scale to maintain proper scale balance Adjust the Display Head for easy viewing 1
12. maintain your scale follow these guidelines Do not place the scale in direct sunlight or direct wind heating ducts etc e Set the scale in an area free of vibration e Set the scale on a firm level surface e Operate in temperatures between 5 C and 40 C 23 F and 104 F Promptly remove expired batteries Bench Receiving Scale Error Messages m eas Item on platter is too heavy oa Remove the item and PRESS Vos Something is stuck between the Remove the item stuck between the upper and lower platter covers covers or replace the upper platter or the upper platter cover has cover been removed _ An item which exceeds the scale Remove the item capacity is on the platter ESE E IF The platter cover is removed Replace the platter cover ERREGER EN F Upper limit is set to a smaller Reset the limits y value than the lower limit Battery voltage is low Replace batteries Refer to POWERING THE SCALE 17 Bench Receiving Scale Accessory An optional mobile cart with rear locking casters is available Mobile Cart Contact your local Hobart Representative for further details E O 18 500 a TOP VIEW 33 960 43 750 V um ON
13. mit setting Battery voltage is low EN GN The total weight product and container displays Bench Receiving Scale Keypad You can use the 6 button keypad to perform functions in two modes Operator Mode e Operator Mode e Setup Mode In Operator Mode you can do the following using the keypad e Weigh products Operate one touch tare Weigh items in batches Toggle between net and gross weight Toggle between kg and Ib TARE KEYPAD FUNCTION Turns the scale on or off Returns scale to zero when nothing is on the platter Operates one touch taring and batch weighing Toggles between net and gross weight Toggles between pounds Ib and kilograms kg Bench Receiving Scale Setup Mode Setup Mode is used to program the scale with specific settings before weighing the product In Setup Mode you can set clear or change e Preset tare e Upper and lower weight limits FUNCTION KEYPAD Turns the scale on or off gt Clears values in upper and lower weight limit and preset tare modes CLEAR Used to enter and exit Setup Mode Programs preset tare OR Allows you to move left to change each digit value in preset tare and weight limit modes NET Decreases upper and lower weight limit values and preset tare values by one Increases upper and lower weight limit values and preset tare values by one Bench Receiving
14. the Scale productivity of the scale Clean the scale as needed Cleaning To clean the scale 1 Dampen a soft cloth with mild detergent and water solution 2 Wipe down the scale housing and platter CAUTION Look At This DO NOT splash or hose down the scale If water gets into the display it will blank out or the weight will be unstable Open the display and allow it to dry DO NOT use solvents to clean the scale Bench Receiving Scale DO use 5 Chlorine Bleach 5 25 DON T exceed chemical Sodium Hypochlorite manufacturer s recommended Ratio Bleach Water Concentration Concentrations for sanitizer 1 250 ltsp Tegal 200 ppm 1 500 1 2tsp 1gal 100 ppm 1 1000 1 4 tsp 1 gal 50 ppm DON T use solutions of greater than 200 ppm concentration of chlorine 1 2000 1 8 tsp 1 gal 25 ppm cleaners FDA Code of Regulations Vol 21 require solutions containing chlorine to be of no greater concentration than 200 ppm Solutions containing concentrations greater than 200 ppm chlorine will accelerate corrosion of metals Proper cleaning solvent is available from your local Hobart service office for all rubber surfaces Observe the instructions on the bottle BEFORE USING CLEANING SOLVENT ALL FOOD PRODUCTS AND PACKAGING MATERIALS MUST BE REMOVED FROM THE AREA OR CAREFULLY PROTECTED ALSO ALL ODOR OF THE CLEANER MUST DISSIPATE BEFORE FOOD PRODUCTS OR PACKAGING MATERIALS ARE EXPOSED Maintaining To