Home
Hitachi KP-F140F Digital Camera User Manual
Contents
1. 1 5 Section name and functions 2 6 Connector 1 AA A A AA A A AA A 4 4 4 4 2 7 Camera mounting A M 3 8 Lens Q 3 9 Control and states register CSR 121 4 10 Video format 10 1 1 Trigger timing chart 1 2 1 2 Specifications 1 6 13 Dimensions A A A A
2. 17 1 4 CD ROM 1 8 Overview The KP FD140F FD32F are single CCD type RGB color camera which utilized the progressive scan CCD image sensor with square pixel for SXGA VGA format of 1 2 inch which adopted the RGB primary color mosaic filter The KP F140F F32F are a monochrome CCD camera which utilized the progressive scan CCD image sensor with square pixel for SXGA VGA format of 1 2 inch The KP F83F is a monochrome CCD camera which utilized the progressive scan CCD image sensor with square pixel for XGA format of 1 3 inch By adoption of an IEEE1394 b interface high speed connection of maximum of 800 Mbps can be possible without an image capturing board and special connecting Moreover by daisy chain construction of multiple camera system can be easily performed 1 Connected to PC by IEEE1394 b standard cable when PC connected to camera has IEEE1394 b interface Standard composition Check when unpacking Camera with IR cut filter PNE REI PTE O A D EE EE CEE CN CL D CE 1 CD ROM IIDC DRIVER demonstration viewer software and Documents EHRT 1 Composition Table Software License mme 1 High resolution The 1 2 inch 1 450 000 pixels KP FD140F F140F the 1 3 inc
3. 6 AUTO EXPOSURE CSR FOFO 0804 h At auto gain or shutter AES setting the sensitivity is automatically adjusted to maintain the proper video level Manual adjustment Setting value 820000xx h xx 00h to FFh standard 80h Video level decreases toward 00h and increases toward FFh 7 GAMMA CSR FOF0 0818 h Gamma correction is adjusted OFF Setting value 80000000h Gamma correction is set to OFF Manual adjustment Setting value 820000xx h xx 00h to FFh Standard 00h Adjust the detail gamma 8 TRIGGER CSR FOFO 0830 h Sets external trigger operating mode OFF Setting value 80000000h Input Trigger function set to OFF Manual adjustment Setting value 8xyz0000 h 2 LOW ACTIVE 3 HIGH ACTIVE POLARITY 0 PORT1 2 PORT2 E SOFTTRIGGER SOURCE 2 0 MDOEO 1 MODE 1 3 MODE3 E MODE14 F MODE15 MODE External trigger signal polarity is switched at value x Trigger source is switched at value y Trigger mode is switched at value z See Trigger operation and timing chart page 13 to 16 9 TRIGGER DELAY CSR FOFO 0834 h Adjust a gap of few time form noticing trigger pulse to starting exposure OFF Setting value 80000000 h Trigger delay is set OFF Duration of delay adjustment Setting value 82000xxx h xxx 000h to FFFh standard 000 h Adjust the delay time from 000h 0 4 u s to FFFh 3931 6 u s by 0 96 U s steps 10 SOFTWARE TRIGGER CSR FOFO 0
4. 3 TIME STAMP CSR F200 000C h The cycle timer value of 1394 buses can be added to image data as the time stamp OFF Setting value 80000000 h ON Setting value 82000000 h If TIME STAMP is ON first 4 byte of image data is changed to time stamp information as follows Oh 1h 2h 3h 31302928272625242322212019181716151413121110 9 8 7 6 5 4 3 2 1 0 Second Count Cycle Count Cycle Offset 4 HD RESET CSR F200 0010 h When using TRIGGER MODE internal HD is reset and start exposure OFF Setting value 80000000 h ON Setting value 82000000 h 5 CYCLE TIMER SYNC CSR F200 0010 h Camera is synchronized to cycle timer in same bus All camera set to normal mode and same frame rate OFF Setting value 80000000 h ON Setting value 82000000 h 6 PORT1 OUTPUT CSR F300 0200 h PORT2 OUTPUT CSR F300 0204 h Output strobe pulse camera VD other port input switched PORT SETTING from PORT1 PORT2 These timing can be signal timing of PORT1 and PORT2 for trigger operation OFF Setting value 80000000h Signal output absent ON Setting value 8xyyyzzz h x 2 LOW ACTIVE THRUGH 3 HIGH ACTIVE REVERSE yyy 000h to FFFh 222 000h to FFFh When output signal is Strobe out Camera VD polarity is switched at value of x When output signal is Other port input polarity is reversed or not reversed at value of x When output signal is Strobe out Other port input adjust delay time at value of yyy from 0 2 to
5. o o Format Image Size Color Coding Packet Size Byte 656 x 492 656 x 492 656 x 492 YMONO 8 7872 5940 3936 656 x 492 YMONO 16 7872 5940 3936 656x492 8 787209 504008 3036 656 492 656 492 640 480 640 480 640 480 8 7680 5760 3840 640 480 YMONO 16 7680 5760 3840 640 x 480 640 x 480 640 x 480 3 KP FD32F only required S800 data rate 3 KP F83F A Fixed format 0 Se ee 0 5 640 480 YMONO8 O O 1024 x 768 YMONO 8 O 800 x 600 YMONO 16 1024 x 768 YMONO 16 B Free format Format7 7 0 1024 768 8 8192 6144 4096 2048 1024 768 YMONO 16 8192 6144 4096 2048 required 5800 data rate Trigger operation and timing chart 1 Normal mode 12 Shutter time Shutter time 1 Camera setting Camera setting value Shutter time 1 1 Strobe delay 1 14 Strobe output High output Strobe Data output Strobe duratiori2 3 VD output Low active 1 0 27 3930 51 us 0 96 u s step x 2 0 96 3931 2 us 0 96 u s step 3 Shutter Time Strobe delay when duration time is set to 000h DATA 3 2 ms KP FD140F 1280 x 960 RGB24 15fps 3 2 ms KP F140F 1280 x 960 Mono8 15fps 0 9 ms KP F32F 640 x 480 Mono8 60fps 0 9 ms KP
6. 18 dB in response to light source brightness 5 SHUTTER CSR FOFO 081C h Sets electronic shutter speed OFF Setting value 80000000 h Switches off shutter operation The shutter speed at OFF is as follows KP FD140F F140F 1 30 second VGA 1 15 second SVGA XGA SXGA KP FD32F F32F 1 60 second KP F83F 1 30 second Manual adjustment Setting value 82000xxx h xxx 000h to 600h Electronic shutter can be set in the range of 10 to 1 100 000 second Shutter speed setting value can be derived as follows ShutterSpeed second a Setting value xyy obtained from exposure time x int log ShutterSpeed int ShutterSpeed 100 10 9 b Exposure time obtained from setting value yy 100h ShutterSpeed 10 x 1 x9 usec Ex 1 Exposure time setting value nnn to obtain 1 125 second 8000 u second x int log 8000 3 8000 100h int 1 C7h dd 10 9 nnn 2C7 Ex 2 Setting value 25Dh that produces 1 234 22 second exposure time 5Dh x9 100h 4269 53 usec _ 1 Mana sec ShutterSpeed 10 x 1 Setting value 83000000 h Auto electronic shutter operates to vary the shutter speed in the range of 10 to 1 100 000 second in response to light source brightness If light is excessive a suitable level is selected for maintaining a video output This function is effective when using microscope or other optical system without an automatic lens iris
7. 3931 4 Uu s by 0 96 U s step When output signal is Strobe out adjust output signal pulse width at value of zzz from 0 96 to 3931 2 5 by 0 96 Ws step But when zzz is set to 000 Strobe out is stopped at the time of end of exposure See Trigger operation and timing chart page 13 to 16 Video format 1 KP FD140F F140F A Fixed format Frame Rate Format Mode Image Size Color Coding 30 15 7 5 3 75 1 875 0 3 640 x 480 4 640 x 480 5 640 x 480 YMONO8 6 640 480 16 1 0 800 600 1 800 600 2 800 600 3 1024 x 768 4 1024 x 768 5 1024 x 768 YMONO 8 6 800 x 600 YMONO 16 O O 7 1024 x 768 YMONO 16 O O O 2 0 1280 960 1 1280 960 2 1280 960 8 O O 6 1280 960 YMONO 16 O O B Free format 7 Format 1360 x 1024 1360 x 1024 1360x1024 8 8192 614409 4096 1360 1024 16 819269 6144 9 4096 1360 x 1024 1360 x 1024 1360 x 1024 X KP FD140F only required S800 data transmission rate 10 3 KP FD32F F32F Fixed format 2 o 35 75 waza oo o o 9 9 640 x 480 640 x 480 EM Gd BOTs OnE ww o o o o ow o o o
8. A class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations Le pr sent appareil n met pas de bruits radio lectriques d passant les limit s applicable aux appareils num riques de classe A prescrites dans le rVglement sur le brouilage radio lectrique dicter par le minist re des communications du canada Phenomena inherent to imaging device The following phenomena are inherent to a charge coupled device imaging element and do not indicate malfunction 1 Smear and blooming Vertical bands are visible when a strong light enters the scene Adjust the camera aiming direction carefully to avoid strong direct or reflected light 2 Fixed pattern noise High ambient temperature can cause fixed pattern noise to appear throughout the scene 3 Moire Interaction between patterns can produce an additional phantom pattern to appear The CCD picture elements pixels are arranged in a pattern which can interact with a pattern in the scene e g a performer wearing a finely striped necktie to result in a Moire pattern The effect should be considered when selecting costumes props and other scene elements 4 Ghosting Strong direct or reflected light near an object of interest can cause ghosting of the object to appear in the picture effect is more obtrusive with certain iris settings and lens types Select the scene layout and camera pointing direction carefull
9. Electric Europe GmbH Head Office Weiskircher Stra B e 88 Jugesheim D 63110 Rodgau Germany Phone 49 0 6106 6992 0 Fax 49 0 6106 1690 6 URL http www hitachi service net Hitachi Kokusai Electric U K Ltd Head Office Windsor house Britannia Road Waltham Cross Hertfordshire EN8 7NX United Kingdom Phone 44 0 845 121 2177 Fax 44 0 845 121 2180 Leeds Office Brookfield House Selby Road Garforth Leeds LS 25 1NB Unitde Kingdom Phone 44 0 113 287 4400 Fax 44 0 113 287 4260 URL http www hitachi denshi uk com
10. F83F 1024 768 Mono8 30fps 0 9 ms KP FD32F 640 x 480 RGB24 60fps 2 Fixed shutter mode External trigger operating mode Mode 0 When external trigger signal is high active after the trigger signal rise edge the strobe signal start end can be set to determine the strobe time At the strobe signal falling edge the internal VD signal is reset and the video data are transmitted More than 10 45 More than T1 1 Trigger input High High active Low Port1 Port2 output Output delay Port1 Port2 Trigger input signal width More than 10 us High active 2 Shutter time Strobe output High active lt _ Strobe duration2 6 Data output VD output Low active 9H i iStrobe duration 1 1 2 0 18 3930 42 us 0 96 u s step Self framerate 3 0 22 3930 46 us 0 96 u s step 4 0 27 3930 51 us 0 96 u s step 5 0 96 3931 2 u s 0 96 u s step 6 Shutter Time Strobe delay when duration time is set to 000h 3 One trigger mode External trigger operating mode Mode 1 When external trigger signal is high active after the trigger signal rise edge the strobe signal start end can be set to determine the strobe time At the flash signal falling edge the internal VD signal is reset and the video data are transmitted More than T1 1 Trigger input High High active Low 9 More than 10 4s More than 1044s Port1 Port2
11. V rificaton de s curit Apr s tout travail d entretien ou de r paration de l appareil demander au technicien de r paration d effectuer les v rifications de s curit pour s assurer que l appareil est en bon tat de marche 23 Montage au mur ou au plafond L appareil ne pourra tre mont au mur ou au plafond que de la mani re recommand e par le fabricant 24 Chaleur Eloigner l appareil des sources de chaleur telles que radiateurs appareils de chauffage cuisini res et de tour produit engendrant de la chaleur y compris les amplificateurs IMPORTANT NOTICE USA For Canada These products have been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this product in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications not expressly approved by Hitachi Denshi responsible for compliance could void the user s authority to operate the equipment This product does not exceed the class
12. gt Porti Port2 Trigger input signal width output Output delay i High active 2 14 1 i Shutter time Integration time Shutter time Integration time Shutter time Trigger delay 4 22 T2 7 idelay 4 Strobe output High active gt Data output Strobe duration2 6 VD output eee Low active 9H 1 1 11 sec 7 T2 27 s KP FD140F F140F Self framerate 19 KP FD32F F32F 92 0 18 3930 42 0 96 u s step 3 0 22 3930 46 0 96 u s step abo PSRS 4 0 27 3930 51 H s 0 96 u s step 85 0 967 3931 24 s 0 96 u s step Shutter Time Strobe delay when duration time is set to 000h 4 Reset control External trigger operating mode Mode 14 When the external trigger signal is HIGH ACTIVE exposure begins at the rising edge of the trigger signal and ends at the falling edge At the Readout pulse falling edge the internal VD signal is reset and the video data are transmitted More than T1 81 Trigger input High k gt High active 54 More than 104 5 More than 10 45 Port1 Port2 nr m output Output delay rigger input signal wi High active 2 14 46 1 x Shutter time Shutter time integration time Shutter time Ireen integration time 1 delay 3 Pit c ay SSi UO T26D Readout pulse gt 1 Hig
13. s curit et de fonctionnement des fins de r f rence ult rieure 3 Tenir compte des avertissements Tous les avertissements qui figurent sur l appareil et dans le mode d emploi devront tre respect s 4 Observer les instructions Observer toutes les instructions de fonctionnement et d utilisation 5 Nettoyage Avant de proc der au nettoyage d brancher l appareil de la prise secteur pas utiliser de produits de nettoyage liquides ou en a rosol Nettoyer l appareil avec un chiffon humide 6 Fixations Ne pas utiliser de fixations non recommand es par le fabricant de l appareil car elles pourraient tre source de danger 7 Eau et humidit Ne pas utiliser l appareil proximit d eau ar exemple pr s d une baignoire d un lavabo d un vier ou d un bac lessive dans un sous sol humide ou pr s d une piscine etc 8 Accessoires Ne pas placer l appareil sur un chariot un socle un pied un support ou one table instables pourrait tomber blessant gri vement des enfants ou des adultes et tant s rieusement endommag Utiliser exclusivement le chariot le socle le pied le support ou la table recommand s par le fabricant ou vendus avec l appareil Pour tout montage de l appareil respecter les instructions du fabricant et utiliser cette fin l accessoire de montage recommand par le fabricant 9 L appareil mont sur son chariot devra tre d plac avec pr caution Des arr ts brusques une force ex
14. service or repairs to this product ask the service technician to perform safety checks to determine that the product is in proper operating condition 23 Wall or Ceiling Mounting The product should be mounted to a wall or ceiling only as recommended by the manufacturer 24 Heat The product should be situated away from heat sources such as radiators heat registers stoves or other products including amplifiers that produce heat WICHTIGE SICHERHEITSANWEISUNGEN 1 Alle Anweisungen lesen Vor Betrieb des Erzeugnisses sollten alle Sicherheits und Bedienungsanleitungen gelesen werden 2 Die Anweisungen aufbewahren Die Sicherheits und Bedienungsanleitungen sollten f nftigen Bezug aufbewahrt werden Warnungen beachten Die Warnungen auf dem Erzeugnis und in den Bedienungsanleitungen solten beachtet werden 4 Anweisungen befolgen Alle Bedienungsanleitung und Verwendungsanweisungen sollten befolgt werden 5 Reinigung Den Stecker des Ger ts vor Reinigung aus der Steckdose ziehen Keine fl ssigen Reinigungsmittel oder Aerosolreiniger verwenden Zum Reinigen einen feuchten Lappen verwenden 6 Zubeh r Nur vom Hersteller des Erzeugnisses empfohlenes Zubeh r verwenden da es sonst zu St rungen kommen kann Wasser und Feuchtigkeit Dieses Erzeugnis nicht in der N he von Wasser verwenden z B in der N he einer Badewanne eines Waschbeckens einer K chensp le eines Waschzubers in einem nassen Keller der eines Schwimmbecken
15. 000 h Run software trigger ON Setting value 82000000 h OFF Setting value 80000000 h 11 INITIALIZE CSR FOFO 0000 h Return equipment to status at time of release from factory Initialization Setting value 80000000 h 12 MEMORY SAVE EXECUTE CSR FOFO 0618 h Make back up of presently effective memory channels BACK UP execute Setting value 80000000 h 13 MEMORY SAVE Ch SET CSR FOFO 0620 h Select channel carried out memory backup channel set Setting value x0000000h 1 ch1 2 ch2 3 ch3 4 ch4 14 CURRENT MEMORY Loading memory channel designating data LOADBACK UP execute Setting value x0000000 h 0 FACTORY SETUP 1 ch1 2 ch2 3 ch3 4 ch4 CSR FOFO 0624 h 2 Advance CSR 2 1 Image color reproduction and color balance related CSR 1 MASKING CSR F200 0020 h RGB and Ye Cy Mg color saturation and hue can be separately varied 6 vector independent masking Color reproduction detail and fidelity are effectively enhanced When engaged R saturation CSR F200 0024 M hue CSR F200 0050 can be set with color phase and saturation adjusted for each color phase This function is only for KP FD140F and KP FD32F OFF Setting value 80000000 h ON Setting value 82000000 h a MASKING R SATURATION Manual adjustment Setting value 820000xx h b MASKING Y SATURATION Manual adjustment Setting value 820000xx h c MASKING G SATURATON Manual adjustment
16. 0120 h Manual adjustment Setting value 820000xx h xx 00h to FFh standard 00h Color level of RED is adjusted manually Color level is reduced at 00 side and raised at FFh side b PAINT BLACK GREEN CSR F200 0124 h Manual adjustment Setting value 820000xx h xx 00h to FFh standard 00h It is same as RED c PAINT BLACK BLUE CSR F200 0128 h Manual adjustment Setting value 820000xx h xx 00h to FFh standard 00h It is same as RED 2 2 Setting of other function related CSR 1 PORT1 CSR F200 0000 h OFF Setting value 80000000 h SELECT INPUT OUTPUT SIGNAL Setting value 8200000x h x 0 TRIGGER IN 1 STROBE OUT 2 VD OUT 3 PORT2 OUT Input and output signal is switched at value of x When TRIGGER SOURCE is PORT1 x is set to TRIGGER automatically PORT2 CSR F200 0004 h OFF Setting value 80000000 h SELECT INPUT OUTPUT SIGNAL Setting value 82000000x h x 0 TRIGGER IN 1 FLUSH OUT 2 VD OUT 3 PORT1 OUT It is same as PORT1 2 READOUT SET CSR F200 0008 h Set readout source for mode 14 Reset control trigger operation Setting value 80000000 h ON Setting value 8xy0000z h 2 LOW ACTIVE 3 HIGH ACTIVE y 0 SourceIDO PORT 1 2 SourceID1 PORT2 E SourcelD7 Software 2 1 SET Readout signal polarity is switched at value of x Readout signal source is switched at value of y When set SourcelD7 if 218 set to 1 a picture is outputted and 2 becomes 0 automatically
17. 9 ms KP FD32F 640 x 480 RGB24 60fps 3 2 ms KP F140F 1280 x 960 Mono8 15fps 0 9 ms KP F32F 640 x 480 Mono8 60fps 0 9 ms KP F83F 1024 x 768 Mono8 30fps DATA VD output Low active 5 gt 0 34 Note When VD synchronization function please set same frame rate speed If set difference frame rate cameras are not synchronized normally Specifications Specifications of KP FD140F F140F FD32F F32F F83F are showing 16 KP FD140F F140F KP FD32F F32F KP F83F 1 Imaging device 1 2 inch interline CCD 1 3 inch interline CCD Total pixels 1434 H x 1050 V 692 H x 504 V 1079 H x 789 V Effective pixels 1392 H x 1024 V 656 H x 492 V 1034 H x 779 V Pixel size 4 65 u m x 4 65 u m V 9 9 x 9 9 V 4 65 u m x 4 65 u m V Color filter RGB primary color mosaic filters FD140 FD32F 2 Scanning system Progressive scan 3 Synchronization Internal external auto selection 4 Video signal output Interface IEEE1394 b FireWire800 Protocol IEEE1394 based Digital Camera Specification Version 1 31 compliant Transfer rate 800 400 200Mbps Image format RGB24 48 YUV4 2 2 RAW8 RAW16 for FD140F FD32F MONOS 16 for all model Image size 1360 H x 1024 V 656 H x 492 V 1024 H x 768 V 1280 H x 960 V 640 H
18. CCD camera KP FD140F KP FD32F KP F140F KP F32F KP F83F Operation Manual Thank you for producing this fine Hitachi Kokusai Electric CCD camera Before using the camera please read this operation manual carefully and keep this manual on file for ready reference in the future Hitachi Kokusai Electric RoHS Compliant These products compile with the requirement of he RoHS Restriction of the use of Certain Hazardous Substances in Electrical and electronic Equipment Directive 2002 95 EC Ref No KV 0142 Declaration of Conformity Manufacturer s Name Hitachi Kokusai Electric Inc Manufacturer s Address 4 14 1 Sotokanda Chiyoda ku Tokyo 101 8980 Japan Representative s Address Hitachi Kokusai Electric Europe GmbH in the EU Weiskircher Stra e 88 J gesheim D 63110 Rodgau Germany Hitachi Kokusai Electric U K Ltd Windsor House Britannia Road Waltham Cross Hertfordshire 8 7NX United Kingdom declares that the product Product Name CCD Camera Model Number s KP F140F KP FD140F conforms to the following Standards EMC EN 61000 6 3 2001 EN 61000 6 1 2001 Supplementary Information The product complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC Signature Yamada Y M Khtou Senior Manager Managing Director Quality Assurance Department Il Hitachi Kokusai Electric Europe GmbH Hitachi Kokusai Electric Inc Hitachi
19. Kokusai Electric U K Ltd Date 1 Mar 2006 V3T 0078 Ref_No KV 0143 Declaration of Conformity Manufacturer s Name Hitachi Kokusai Electric Inc Manufacturer s Address 4 14 1 Sotokanda Chiyoda ku Tokyo 101 8980 Japan Representative s Address Hitachi Kokusai Electric Europe GmbH in the EU Weiskircher StraBe 88 J gesheim D 63110 Rodgau Germany Hitachi Kokusai Electric U K Ltd Windsor House Britannia Road Waltham Cross Hertfordshire 8 7NX United Kingdom declares that the product Product Name CCD Camera Model Number s KP F32F KP FD32F conforms to the following Standards EN 61000 6 3 2001 EN 61000 6 1 2001 Supplementary Information The product complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC Signature Senior Manager Managing Director Quality Assurance Department II Hitachi Kokusai Electric Europe GmbH Hitachi Kokusai Electric Inc Hitachi Kokusai Electric U K Ltd Date 1 Mar 2006 V3T 0079 Ref No KV 0145 Declaration of Conformity Manufacturer s Name Hitachi Kokusai Electric Inc Manufacturer s Address 4 14 1 Sotokanda Chiyoda ku Tokyo 101 8980 Japan Representative s Address Hitachi Kokusai Electric Europe GmbH in the EU Weiskircher StraBe 88 J gesheim D 63110 Rodgau Germany Hitachi Kokusai Electric U K Ltd Windsor House Britannia Road Waltham Cross Hertfordshire 8 7NX U
20. Setting value 820000xx h d MASKING C SATURATION Manual adjustment Setting value 820000xx h e MASKING B SATURATION Manual adjustment Setting value 820000xx h f MASKING M SATURATION Manual adjustment Setting value 820000xx h g MASKING R HUE Manual adjustment Setting value 820000xx h h MASKING Y HUE Manual adjustment Setting value 820000xx h XX XX XX XX XX XX XX XX CSR F200 0024 h 00h to FFh standard 80h CSR F200 0028 h 00h to FFh standard 80h CSR F200 002C h 00h to FFh standard 80h CSR F200 0030 h OOhto FFh standard 80h CSR F200 0034 h 00h to FFh standard 80h CSR F200 0038 h 00h to FFh standard 80h CSR F200 003C h OOhto FFh standard 80h CSR F200 0040 h 00h to FFh standard 80h Color phase i MASKING G HUE CSR F200 0044 h Manual adjustment Setting value 820000xx h xx 00h to FFh standard 80h j MASKING C HUE CSR F200 0048 h Manual adjustment Setting value 820000xx h xx 00h to FFh standard 80h k MASKING B HUE CSR F200 004C h Manual adjustment Setting value 820000xx h xx 00h to FFh standard 80h MASKING M HUE CSR F200 0050 h Manual adjustment Setting value 820000xx h xx 00h to FFh standard 80h 2 PAINT BLACK Color level of R G and B can be separately varied This function is only for KP FD140F and KP FD32F a PAINT BLACK RED CSR F200
21. This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet not defeat the safety purpose of the grounding type plug 13 Power Cord Protection Power supply cords should be routed to that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plug convenience receptacles and the point where they exit from the product 14 Lightning For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet This will prevent damage to the product due to lightning and power line surges 15 Overloading Do not overload wall outlets extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock 16 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the product 17 Inflammable and Explosive Substance Avoid using this product where there are gases and also where there are inflammable and explosive substances in the immediate vicinity 18 He
22. ar le fait d ouvrir ou de retirer les caches risque d exposer l utilisateur des tensions dangereuses notamment Confier toute r paration un personnel qualifi 20 Dommages n cessitant r parations D brancher l appareil de la source d alimentation et confier les r parations un personnel qualifi dans les cas suivants a Lorsque le cordon d alimentation ou sa fiche sont endommag s b Si du liquide s est renvers sur l appareil ou que des objets sont tomb s dedans Si l appareil a t expos la pluie ou l eau d Si l appareil ne fonctionne pas normalement lorsqu on observe les instructions d utilisation Ne r gler que les commandes couvertes par le mode d emploi en effet un r glage incorrect des autres commandes pourrait entrainer des dommages et n cessiteront souvent des travaux de r paration co teux par un technicien qualifi pour remettre l appareil en tat de marche e Si l appareil est tomb ou qu il a t endommag f Si l appareil affiche une nette modification de ses performances cela signifie qu il a besoin d tre r par 21 Pi ces de rechange Si l on a besoin de pi ces de rechange veiller ce que le technicien de r paration utilise exclusivement les pi ces de rechange sp cifi es par le fabricant ou des pi ces ayant les m mes caract ristiques que les pi ces d origine Les pi ces de rechange non autoris es risquent de provoquer un feu un choc lectrique et autres dangers 22
23. avy Shock or Vibration When carrying this product around do not subject the product to heavy shock or vibration 19 Servicing Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 20 Damage Requiring Service Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the product c If the product has been exposed to rain or water the product does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to its normal operation e If the product has been dropped or damaged in way f When the product exhibits a distinct change in performance this indicates a need for service 21 Replacement Parts When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part Unauthorized substitutions may result in fire electric shock or other hazards 22 Safety Check Upon completion of any
24. cessive et des surfaces irr guli res pourraient provoquer le renversement de l ensemble appareil chariot 10 Ventilation Les fentes et les ouvertures du coffret sont pr vues pour la ventilation ainsi que pour garantir un fonctionnement en toute s curit de l appareil et le prot ger de toute surchauffe et ces ouvertures ne devront donc tre ni obstru es recouvertes Ne jamais obstruer les ouvertures en placant l appareil sur un lit un sofa un tapis ou toute surface similaire Ne jamais placer l appareil dans un support confin par exemple une biblioth que ou une tag re sans ventilation suffisante ou sans repecter les instructions du fabricant 11 Sources d allmentation L appareil devra tre aliment exclusivement sur le type d alimentation indiqu sur l tiquette signal tique Sil on n est pas s r du type d alimentatio du local consulter le revendeur de l appareil ou la compagnie d lectricit locale Pour les appareils qui fonctionnent sur batterie ou sur d autres sources voir le mode d emploi 12 Mise la terre ou polarisation L appareil est dot d une fiche trifilaire avec mise la terre dont la troisi me broche assure la mise la terre Cette fiche ne rentrera que dans les prises trifilaires de mise la terre Ceci est une mesure de s curit Si la fiche ne rentre pas dans la prise faire remplacer la prise d su te par un lectricien Ne pas rendre vaine la measure de s curit assur e par cett
25. e prise avec mise la terre 13 Protection du cordon d alimentation Acheminer les cordons d alimentation de facon qu on ne risque pas de marcher dessus ou de les coincer sous un objet plac dessus ou contre eux Faire particuli rement attention aux fiches des cordons la proximit des prises et l endroit ils ressortent de l appareil 14 Foudre Pour renforcer la protection de l appareil pendant un orage ou si l on s en loigne ou qu on reste longtemps sans l utiliser le d brancher de la source d alimentation Ceci permettra d viter tout dommage de l appareil la foudre et aux surtensions de ligne 15 Surcharge Ne pas surcharger les prises rallonges et prises multiples car cela pourrait entrainer un risque de feu ou de choc lectrique 16 P n tration d objets et de liquides Ne jamais enfoncer d objets d aucune sorte dans les ouvertures de l appareil car ils pourraient toucher des points de tension dangereuse ou court circuiter des pi ces ce qui pourrait provoquer un feu ou un choc lectrique jamais renverser de liquide d aucune sorte sur l appareil 17 Substances inflammabes et explosives Eviter d utiliser l appareil en pr sence de gaz ainsi qu proximit imm diate de substances inflammables et explosives 18 Chocs ou vibrations violents Lorsqu on transporte l appareil ne pas le soumettre des chocs ou des vibrations violents 19 R parations Ne pas tenter de r parer l aapareil soi m me c
26. h 805 000 pixels KP F83F and the 1 2 inch 330 000 pixels KP FD32F F32F achieve a high resolution of 1360 H x 1024 V SXGA the 1024 H x 768 V and 656 H x 494 V High color fidelity The RGB primary color mosaic filter achieves high color fidelity 6 vector masking Independent six colors masking is the Hitachi innovation for optimizing color balance The saturation and the hue of 6 colors Red blue green cyan magenta and yellow are adjusted independently to deliver the best color in image capture microscope and other applications Daisy chain Multi camera connection is possible by daisy chain System example IEEE1394 b HITACHI citis aues Branch cable Power supply when needed KP FD140F KP FD140F HITACH _ External trigger pes on IEEE1394 b cable Section name and functions Camera Tripod adaptor mounting screw holes POWER STATUS LED 2 LED Green Yellow Power ON Light Off Light off Transmission Blink Off Blink On Transmission pause Blink On Blink Off Lens mount C mount POWER STATUS TA AN A gt jm A 7 A 2 Nae Li IEEE1394 connectors Connect 1394 connector Camera Tripod i mounting screw holes L 1 of using IEEE1394 cable When power is supplied from IEEE 1394 check fo
27. h active 1 250ms Strobe output High active i Strobe duration 6 Data output gt 4 VD output Low active 1 1 1 7 T2 93 u s KP FD140F F140F elf frame rate _ 2 0 19 3930 43 u s 0 96 u s step anie d x 3 0 22 3930 46 u s 0 96 u s step 4 0 28 3930 52 u s 0 96 u s step 5 0 96 3931 2 us 0 96 u s step Shutter Time Strobe delay when duration time is set to 000h Note Special function of rest control trigger The camera shifts to the output of a normal mode continuous output when Trigger B signal passes about 1 3 seconds in the state of High The image is output by inputting the Trigger at the VD cycle for this period It returns to the Reset control mode if Trigger B signal becomes Low However after becoming Low Trigger B the period of 50 ms becomes a Trigger A signal input prohibition period High Trigger input High active M Shutter time integration time Shutter time Readout pulse High active Data output VD output Low active 5 VD synchronization External trigger operating mode Mode 15 Please input the sync pulse of following specification in the case that camera synchronization locks the external synchronization more than 1 self frame rate sec E VD input Low active more than 10 us X XX XX 3 2 ms 140 1280 x 960 RGB24 15fps 0
28. is adjusted Manual adjustment Setting value 820000xx h 00h to FFh standard 80h Can be set in range of 00h to FFh Setting value to 00h side lowers black level FFh side raises black level 2 SHARPNESS CSR FOFO 0808 h Sharpness level adjustment object contour correction Manual adjustment Setting value 820000xx h xx 00h to FFh standard 80h Contour correction can be set in range of 00h to FFh Setting value toward 00h side reduces correction for softer contours Setting toward FFh side increases correction for sharper contours 3 WHITE BALANCE CSR FOFO 080C h White balance adjustment only for KP FD140F and FD32F Manual adjustment Setting value 820 h xx 00h to FFh B gain yy 00h to FFh gain White balance is adjusted manually by adjusting R and B gain Gain is reduced at 00h side and raised at FFh side One Push Auto White Balance AWB Setting value 86000000 h State for automatic white balance adjustment AUTO ATW Setting value 83000000 h White balance is adjusted in real time automatic tracking An effective function when the scene is subject to changes in color temperature of the light source 4 GAIN CSR FOFO 0820 h Electrical sensitivity is adjusted Manual adjustment Setting value 82000xxx h xxx 000h to 1C2h 1dB 019h Adjusts electrical sensitivity in the range of 0 to 18 dB Setting value 83000000 h Gain is automatically adjusted in the range of 0 to
29. n the lens mount ring to adjust the focus Use care not to disturb the lens focus ring 4 Tighten the lens mount screws 2 Zoom lens 1 Set the lens to telephoto and aim toward an object at least 20 meters distant 2 Turn the lens focus ring to adjust the focus 3 Set the lens to wide angle Loosen the 2 Lens mount screws and turn the lens mount ring to adjust the focus Use care not to disturb the lens focus ring 4 Again set to telephoto but adjust the focus by turning the lens mount 5 Repeat these steps and carefully adjust for best focus 6 Finally tighten the lens mount screws Note If using an auto iris lens and the adjustment object distance is less than several meters due to lens depth of focus relationship slight blurring can occur at certain iris positions In this event darken the scene so as to open the iris and adjust the focus or flangeback to prevent the blurring Control and States Register KP FD140F F140F FD32F F32F F83F can be set by entering predetermined setting commands in the Control and Status register CSR of the 1394 based Digital Camera Specification Ver 1 31 Common and camera specific CSR register setting operations are described below Indication example Function name CSR xxxx xxxx h Function description Lower 32 bits of 64 bit CSR address are displayed ex FOFO 0800 h means BUS ID NODE ID FFFF FOFO 0800 h 1 IDC Standard CSR 1 BRIGHTNESS CSR FOFO 0800 h Master black level
30. nce 68 56m s 10 to 200Hz 30 minutes each on XYZ axes Please do not add the strong vibration over long time 24 Shock endurance 490 3m s vertical horizontal once each faze 25 Dimensions 44 W x 44 54 D mm not including lens 26 Mass Approx 130g not including lens 27 Standard composition Camera CD ROM Operation manual Driver SDK Composition UNIT mm MASS APPROX 130g gt POWER STATUS Gl B E E 5 75 PORT 1 PORT 2 e 8 a E eo l COLOR BLACK 2 M3 DEPTH 3 VIEW HITACHI A U1 9 COLOR BLACK COLOR BLACK 2 M3 DEPTH 3 5 7 11 5 34 HITACHI PLATE RATED VIEW 2 2 DEPTH 3 About CD ROM Attached CD ROM has the following composition means folder Reame txt HitachiKokusai 1 Documents Ten Japanese CameraOperationManual J pdf VieweManual J pdf English CameraOperationManual E pdf ViewerManual E pdf Viewersoftware HiKE1394CamView exe Technoscope r Documents ZCLAPI pdf ZCLDrvinstall pdf H Driver COM dll ZCL dil ZCLDrv dll ZCLDrv inf ZCLDRV sys 201 1 77777 COMMON ZCL lib ZCLAPIh lon Sample1 Source cord of sample program 1 x SampleEXE 1 test exe 1 Readme txt The file that explain the direct
31. ngegebenen Stromversorgungsart betrieben werden Wenn Sie nicht sicher sind was f r eine Stromversorgung Sie haben so wenden Sie sich bitte an Ihren Erzeugnish ndler oder an das lokale Elektrizit tswerk Beziehen Sie sich f r Batteriebetrieb oder andere Stromquellen vorgesehene Erzeugnisse bitte auf die Bedienungsanleitungen 12 Erdung oder Polarisierung Dieses Erzeugnis ist mit einem Schutzkontaktstecker mit drei Leitern ausger stet mit einem Erdungskontakt Dieser Stecker pa t nur in ein schuko Steckdose Dies ist eine Sicherheitsma nahme Wenn Sie den Stecker nicht in die Steckdose stecken k nnen so wenden Sie sich bitte an ihren Elektriker damit er die veraltete Schuts des Schutzkontaktsteckers unwirksam 13 Netzkabelschutz Netzkabel sollten so verlegt werden de m glichst nicht darauf getreten wird und da sie nicht eingeklemmt werden mit besonderer Beachtung der kabel an Stackern Verl ngerungskabeln und dem Austritt des Kabels aus dem Erzeugnis 14 Blitzschlag F r zus tzlichen Schutz des Erzeugnisses w hrend eines Gewitters oder bei Nichtverwendung f r lange Zeit den Stecker aus der Steckdose ziehen Dies verh tet Besch digung durch Blitzschlag und Netzspannungsst e 15 berlastung Wandsteckdosen Verl ngerungskabel und eingebaute Bequemlickkeitssteckdosen nicht berlasten da dies Feuer oder elektrischen Schlag verursachen kann 16 Eindringen von Fremdk rpern und Fl ssigkeit Niemals Objekte irgendwelcher Art du
32. nited Kingdom declares that the product Product Name CCD Camera Model Number s KP F83F conforms to the following Standards EMC EN 61000 6 3 2001 EN 61000 6 1 2001 Supplementary Information The product complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC Signature mod Y Yamada M Katou Senior Manager Managing Director Quality Assurance Department Hitachi Kokusai Electric Europe GmbH Hitachi Kokusai Electric Inc Hitachi Kokusai Electric Ltd Date 10th Apr 2006 V3T 0081 IMPORTANT SAFETY INSTRUCTIONS 1 Read Instructions All the safety and operating instructions should be read before the product is operated 2 Retain Instructions The safety and operating instructions should be retained for future reference 3 Heed Warnings All warnings on the product and the operating instructions should be adhered to 4 Follow Instructions All operating and use instructions should be followed 5 Cleaning Unplug this product from the wall outlet before cleaning not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 6 Attachments Do not use attachments not recommended by the product manufacturer as they may cause hazards Water and Moisture Do not use this product near water for example near a bath tub wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool and the like Accessories Do no
33. ory tree of CD ROM 2 HitachiKokusai This folder has documents about camera and viewer software CameraOperationManual J E pdf The operation manual of camera this file in English and Japanese ViewerManual J E pdf The operation manual of viewer software in English and Japanese HiKE1394CamView exe The viewer software 3 Technoscope This folder has driver for using viewer software and SDK Software Development Kit ZCL 1 to develop new software ZCLDrvinstall pdf The install manual of driver ZCLAPI pdf The manual of SDK specifications of library functions Driver The folder including files about driver ZCL 1 COMMON The folder including library file and header file for development using SDK ZCL 1 Sample1 The folder including source codes of each sample software ZCL 1 SampleEXE The folder including EXE file of each sample software Note 1 The included driver and also demonstration software within CD ROM operate only in Windows 2000 2 The viewer software may not operate normal when it is used for the other camera because software for Hitachi Kokusai Electric 3 Inthe case that it stopped normal operating during the use of viewer software stop viewer software turn off and on the camera power supply or pull and push the IEEE1394 cable execute viewer software once again 4 Inthe case that the performance the CPU clock installation memory etc of PC is not sufficien
34. r proper current and voltage Connector Signal connection to IEEE1394 b PORT1 PORT2 Viewer Soft Setting PORT1 PORT2 1 TPB Programmable I O In Out 2 Trigger 3 SPECIAL DATA VD 4 Strobe Flash pulse x 5 SHIELD GND 6 VG POWER GND 7 Programmable I O 8 VP POWER 12V 9 SHIELD GND Camera mounting Attached optional accessory the tripod adaptor TA FD140 mount the camera to a tripod or mounting bracket Screw type U1 4 20 L Length L 4 to 5 5mm Screws longer than 5 5 mm can cause internal damage while less than 4 mm prevents secure fastening and risks dropping to cause damage and injury Lens CAUTION Observe the dimensions of the lens mounting selection as illustrated at the right If the dimensions are not observed do not use such a lens Lens optics because the lens and the camera will be damaged Lens flange Max 9mm Flangeback adjustment is needed in cases where focus cannot be obtained by normal lens focus operation or focus is lost at the maximum telephoto and wide angle settings of a zoom lens In such cases open the lens iris and adjust as follows 1 Fixed focus lens 1 Set the lens focus ring to infinity 2 Aim toward an object at least 20 meters distant 3 Loosen the 2 lens mount screws and tur
35. ra through the lens partial deterioration in picture quality will result 4 To obtain stable performance for long time When the camera is used continuously for long time under high ambient temperature the inside electrical parts become deteriorated resulting in shortening its life To use the camera continuously for long time the highest temperature must be below 40 5 Connectors Confirm the power is off before connecting or disconnecting a signal cable Grasp connectors by the body not the attached wires 6 Cleaning Use a blower or a lens brush to remove dusts on the lens or the optical filter Wipe dirts on the case off with dry soft cloth If dirks are hardened wipe them off with cloth moistened with neutral detergent liquid wipe the cover with dry cloth Do not use benzene thinner alcohol liquid cleaner or spray type cleaner In event dust or other debris is lodged between the CCD and optical filter consult dealer for cleaning by an optical technician Table of Contents 1 Overview m 1 2 Standard Composition O P 1 3 Features 1 4 System example A A A
36. rch die ffnungen in das Ger t schieben da diese unter hoher Spannung stehende Teile ber hren oder kurzschlieRen k nnen wodurch es zu Feuer oder elektrischem Schlag kommen kann Niemals Fl ssigkeiten irgendwelcher Art auf das Erzeugnis versch tten 17 Entflammbare und explosive Substanzen Vermeiden Sie Verwendung dieses Erzeugnisses an Orten mit Gasen bzw entflammbaren oder explosiven Substanzen in der direkten Umgebung 18 Starke st e oder Vibrationen Setzen Sie das Erzeugnis beim Transport nicht starken St en oder Vibrationen aus 19 Wartung Versuchen Sie nicht dieses Erzeugnis Selbst zu warten da Sie sich durch ffnen bzw Entfernen von Abdeckungen hohen Spannungen und sonstigen Gef hrdungen ausserzen k nnen Beziehen Sie sich f r jegliche Wartung auf qualifiziertes Wartungspersonal 20 Besch digung die Wartung erfordert Ziehen Sie den Stecker dieses Erzeugnisses aus der Steckdose und wenden Sie sich an qualifiziertes Wartungspersonal wenn eine der folgenden Bedingungen vorliegt a Wenn das Netzkabel oder der Stecker besch digt ist b Bei Eindringen von Fl ssigkeit oder Fremdk rpern in das Ger t c Wenn das Erzeugnis Regen oder Wasser ausgesetzt worden ist d Wenn das Erzeugnis bei Befolgen der Bedienungsanleitungen nicht normal funktioniert Nur die Regelelemente verstellen die in den Bedienungsanleitungen behandelt werden da unangemessene Einstellung anderer Regelelemente Besch digung verursachen kann und oft be
37. s usw Aufstellung Das Erzeugnis nicht auf einen unstabilen Wagen Stand DreifuR Tr ger oder Tisch stellen Das Erzeugnis kann sonst herunterfallen und ein kind oder einen Erwachsenen schwer verietzen Au erdem kann das Ger t schwer besch digt werden Nur mit einem Wagen Stand Dreifu Tr ger oder Tisch verwenden der vom Hersteller empfohlen oder mit dem Erzeugnis verkauft worden ist F r jegliche Anbringung sollten die Anweisungen des Herstellers befolgt werden und das vom Hersteller empfohlene Anbringungszubeh r sollte verwendet werden 9 Eine Kombination von Erzeugnis und Wagen sollte vorsichtig bewegt werden Schneller Halt berm ige Krafteinwirkung und unebene Oberfl chen k nnen Umkippen der kombination von Erzeugnis und Wagen verursachen 10 Ventilation Schlitze und ffnungen im Geh use dienen der Ventilation Sie sind f r zuverl ssigen Betrieb des Ger tes und Schutz vor berhitzung erforderlich und d rfen nicht blockiert oder abgedeckt werden Die ffnungen sollten niemals dadurch blockiert werden da das Ger t auf ein Bett ein Sofa einen Teppich oder eine hnliche Oberfl che gestellt wird Das Ger t sollte nur dann in Einbauinstallierung wie in einem B cherschrank oder einem Gestell verwendet werden wenn angemessene Ventilation vorgesehen ist bzw Die Anweisungen des Herstellers befolgt worden sind 11 Stromversorgung B Dieses Erzeugnis sollte der auf dem Typenschild a
38. t viewer software may not execute normally Please use PC of following specification Item Specifications CPU Intel Celeron 533MHz or more Memory 256MByte or more Display Card 24bit RGB color display card or more Interface Card Built in OHCI IEEE1394 port or Operating System Windows 2000 5 Hitachi Kokusai Electric Inc does not guarantee regarding the faulty damage of the hardware and also software of the customer by a driver and also viewer software 6 SDK is out of support 18 Hitachi Kokusai Electric Inc UDX Akihabara Bldg 14 1 Kanda 4 choume Chiyoda ku Tokyo 101 8980 Japan Phone 03 5209 5931 Fax 03 5209 6119 URL http www h kokusai com Beijing Office Beijing Fortune Building 5 Dong San Huan Bei lu Chao Yang District Beijing 100029 Chaina Phone 86 0 10 6590 8755 8756 Fax 86 0 10 6590 8757 HITACHI KOKUSAI Electric AMERICA LTD Headquarters and 150 Crossways Park Drive Woodbury New York 11797 U S A Northeast Office Phone 1 516 921 7200 Fax 1 516 496 3718 West Office 371 Van Ness Way Suite 120 Torrance CA 90501 U S A Phone 1 516 921 7200 Fax 1 310 328 6252 Midwest Sales Phone 1 330 334 4115 Fax 1 516 496 3718 Service 1 989 345 5379 South Sales Service 1 256 774 3777 Parts Center phone 1 516 682 4435 Fax 1 516 921 0993 Latin Sales phone 1 519 682 4420 Fax 1 516 496 3718 Hitachi Kokusai
39. t place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the product Use only with a cart stand tripod bracket or table recommended by the manufacturer or sold with the product Any mounting of the product should follow the manufacturer s instructions and should use a mounting accessory recommended by the manufacturer 9 Moving A product and cart combination should be moved with care Quick stops excessive force and uneven surfaces may cause the product and cart combination to overturn 10 Ventilation Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating and these openings must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or other similar surface This product should not be placed in a built in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to 11 Power Sources This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supply to your home consult your product dealer or local power company For products intended to operate from battery power or other sources refer to the operating instructions 12 Grounding or Polarization
40. tr chtliche Arbeit durch einen qualifizierten Techniker erfordert um das Erzeugnis wieder zu normalem Betrieb zur ckzubringen e Wenn das Erzeugnis fallen gelassen oder besch digt worden ist f Wenn das Erzeugnis eine klare nderung in der Leistung zeigt dies weist darauf hin da Wartung erforderlich ist 21 Ersatzteile Wenn Ersatzteile erforderlich sind darauf achten da der Wartungstechniker nur die vom Hersteller festgelegten Ersatzteile oder Teile mit den gleichen Charakteristiken wie die urspr nglichen Teile verwendet Unautorisierte Ersatzteile k nnen Feuer elektrischen Schlag oder sonstige Gef hrdungen verursachen 22 Sicherheitspr fung Bitten Sie den Wartungstechniker nach der Vollendung von Wartung oder Reparaturarbeiten an diesem Erzeugnis um die Durchf hrung von Sicherheitspr fungen um zu bestimmen daR das Erzeugnis im angemissenen Betriebszustand ist 23 Anbringung an der Wand oder an der Decke Das Erzeugnis sollte nur entsprechend den Empfehlungen des Herstellers an einer Wand oder an der Decke angebracht werden 24 W rme Das Erzeugnis sollte fern von W rmequellen wie Radiatoren Heizwiderst nden fen und anderen W rme erzeugenden Erzeugnissen einschlie lich Verst rkern aufgestellt werden MISES EN GARDE IMPORTANTES 1 Lire les instructions Lire toutes les instructions de s curit et de fonctionnement avant de faire fonctionner l appareil 2 Conserver ces instructions Conserver les instructions de
41. x 480 V 800 H x 600 V 1024 H x 768 V 640 H x 480 V 800 H x 600 V 640 H x 480 V Frame rate 15fps 1360 x 1024 60fps 656 x 492 30fps 1024 x 768 5 Standard sensitivity 2000Ix F5 6 KP FD32F F32F 2000lx F8 KP FD140F F140F F83F 6 Minimum illumination 10Ix F1 4 Gain KP FD32F F32F F1 4 Gain KP FD140F F140F F83F 7 Gain Auto Manual 0dB to 18dB 8 Electric shutter Auto AES Manual VARIABLE 1 100 000 second to 10 second 9 External trigger shutter Mode Fixed shutter ModeO One trigger Model Reset control Mode14 VD Sync Mode15 Input Via IEEE1394 cable Software trigger Our company original method Hardware trigger 10 Power supply Approx 4 1W DC 12V Approx 3 5W DC 12V Approx 3 2W DC 12V 11 White balance ATW MANUAL One Push FD140F FD32F 12 Gamma OFF LUT 13 Masking OFF ON 6 color independent masking 14 Saturation Adjustable FD140F FD32F 15 Sharpness Adjustable 16 Brightness Adjustable 17 Time stamp OFF ON 18 Cycle timer sync OFF ON 19 Daisy chain Possible Even if there is no repeater If two are connected the frame rate become half 20 Lens mount C mount Flange back adjustment 21 Power supply DC 8V to 30V Via IEEE1394 cable 22 Ambient temperature Operating 10 C to 50 C 30 to 80 RH Note If operated continuously be sure to use at 0 C to 40 C 104F for long term stable performance Storage 20 C to 60 C 20 to 90 RH 23 Vibration endura
42. y in order to avoid this effect Operating considerations Notes to users 1 Important safety notes Use this camera with a 12VDC power supply Observe that flammable objects water or metal do not enter the camera interior These may lead to failure or accident Do not modify the camera or use the camera with external covers removed These may cause failure void any warranties and pose a safety hazard Sop using the camera at the approach of electrical storm thunder audible Protect the camera from rain if using it outdoors In event the camera shows any abnormality switch off the camera and disconnect the power cord Contract a Hitachi Denshi service representative 2 Handling Do not attempt to remove cover When installing or removing a lens be sure to use care that water or dust dose not enter the inside of the camera 3 Installing and storage Avoid installing or storing the camera in the following environments Environments exposed to direct sunlight rain or snow Environments where combustible or corrosive gas exists Excessively warm or cold environment Operating ambient temperature 10 to 50 Humid or dusty environment Place subjected to excessive vibration or shock Environment exposed to strong electric or magnetic field Do not aim the camera lens at the sun Do not shoot strong light When such a scene is shot vertical trailing will appear However this is not due to failure In case strong light enters came
Download Pdf Manuals