Home

Health O Meter 2000KL Scale User Manual

image

Contents

1. Also used to scroll up in the menu aj 3 PRINT Prompts entry of data to calculate the patient s Body Mass BMI Index BMI PRINT Prints patient s data if printer is connected to the scale Prompts entry of patients identification number ID This ID will be stored with all the weighing made until is cleared or a different ID is stored Prompts entry of TARE value that will be deducted from EJE TARE the weight on the platform Also releases tare weight returns display to zero EXIT EXIT Reverts back one step when in the menu and data entry modes ENTER Used to enter commands and values into the scale 13 MENU Enters the menu of the scale OPERATION INSTRUCTIONS MENU In the menu screen the user can set preferences and or instruct the scale how to handle stored data The menu can be navigated using the up and down keys 4 v or by entering the associated menu position number with the keypad The menu has a roll over way of working when the user scrolls to the bottom of the menu and presses the down button it will return to the top of the menu Indicator of menu position scroll through the menu 02 Tare Weight options with a and w keys 03 Data Management P gt y Exit Active menu option is marked by inverted color na Ceresin C 544i nia ar er El IC DCNS AE Cuctam Catinae UD 3V 51 el i dE LI Il igs 06 System Test F la se Oder 07 User Settings 08 Exit Figure 8 Main
2. Keep mast and base locked at all times except when removing mast from base for storage ASSEMBLY INSTRUCTIONS Attaching the Display and Scale to the Patient Lifter LOAD CELL CABLE DISPLA Y REAR COVER DISPLAY ASSEMBLY PHILLIPS PAN HEAD SCREW NC8 32x5 16 LIFTER BOOM DISPLAY SUPPORT A PLASTIC WASHER HEAD SCREW NC 3 8 20 x2 1 2 HEXAGON HEAD SCREW NC3 8 20 x1 3 4 LIFTER MAST ASSEMBLY INSTRUCTIONS 4 Connect the Lifter Boom and the Display Support to the Lifter Mast using the NC 20x2 2 hex screw and tighten the self lock nut on its other side Note This screw is the axis of the Lifter Boom so it is imperative that the three parts Lifter Boom Lifter Mast and Display Support be assembled in the proper order Place the Plastic Washers on either side of the Lifter Boom screw hole to prevent friction With the Boom hooks facing down place the Lifter Boom and Washers inside the two sides of the Lifter Mast and align the holes Place the Display Support over the Lifter Mast and Lifter Boom and align holes Thread the screw through all three parts and tighten the self lock nut on the other side well 5 Insert the shaft end of the Pump into the eared bracket on the Lifter Boom and align the holes Slip the 1 3 4 nut through the bracket and the Pump shaft hole Tighten with locknut 6 Insert the Base Adjustment Lever into its socket at the back of the Lifter Base Check to see that the bum
3. line press AM PM the ENTER button once AV to change Enter 04 32 01 19 OPERATION INSTRUCTIONS Set the date using the up and down keys 4 v and enter the values on the keypad 10 05 03 AV to change Enter 02 About UPSD 10625 This screen displays the software version of the scale PIC Ver 210623 LoadCell 10622 Last Update 01 15 04 Exit Enter 06 SYSTEM TEST gt 02 USB Connection 03 Ul Test w AV to change Enter 01 Battery lest The scale will display the estimated amount of battery life remaining until the batteries will have to be replaced NOTE In order to complete the battery test the scale must be powered by batteries only Unplug the scale from AC power source prior to battery test 02 USB Connection The scale will test the connection to the PC and will display a message Connection is OK or NO Connection If NO Connection is displayed check your USB connections on the scale and on your PC and retest the connection Refer is OK Na to qualified service personnel if problem persists Connection 20 OPERATION INSTRUCTIONS 03 UI Test The scale has a diagnostic routine where it tests the User Interface Ul hardware functionality LCD keypad In order to Pleacclbroas do this the user has to press all the keys according to the 4 messages displayed on the screen If the requested command was not received or wrong button was pressed the followin
4. weigh 3 Carefully move the patient to a lying position on the stretcher Note lay the patient s center mass as close as you can to the center of the stretcher 4 Wheel the lifter scale close to the stretcher and lower the boom with the hoops as far as 5 10 12 cm 25 cm from the patient s body 5 Connect the four hanging loops of the stretcher to the four hooks at the end of each Stretcher Hoop making sure that the loops are hanging freely from the four hooks Note Make sure both hooks connecting the load cell assembly beam lie on the lifter boom If only one of the hooks lies on the beam it can cause inaccurate readings of weight 6 Tighten the hydraulic control valve knob by turning it clockwise The control valve knob is located on the Pump near the Pump handle Use the Base Adjustment Lever to widen the Lifter Base The Base must be spread to the widest possible position to maximize stability 8 Pump the hydraulic Pump handle to lift the Stretcher and patient until the entire Stretcher is hanging from the Stretcher Hoops and is not touching the bed or any other object Do not lock the Wheel on the Lifter Base If needed the Base will move slightly to adjust for balance Caution Never move patient away from bed or leave patient unattended Taking Weight Measurements 1 The scale will calculate the patient s weight Depending upon the movement of the stretcher the scale may take several seconds to lock into the weight W
5. Health o meter Pro P u s PRO PLUS STRETCHER SCALE MODEL 2000KL OPERATION MANUAL AA0339 0 PRO PLUS STRETCHER SCALE MODEL 2000KL Thank YOU for your purchase of this product Please read this manual carefully and keep it handy for ready reference TABLE OF CONTENTS CAUTION AND WARNING ica 2 SRESIFICA MON i hai Wad Kd kad O da R RE EAC 3 ASSEMBLYINSTRUCTIO Nasa ias 4 A a CEE 10 OPERATION INS TRUG TON Sisi ion 11 MAINTENAN Esso dais 23 TROVBEESHOOTIN Gure 24 CALCIBRA TION PAM A GO O Ed GG 25 EXPLODED VIEW OPSCALEG GiG Zad e io GG Ado areata 25 RAS OE aaa 21 WARRANTY sas ee hatin eerie len acter dr A S 28 CAUTION AND WARNING To prevent injury and damage to your scale please follow these instructions very carefully To ensure proper operation of the ProPlus Stretcher Scale this operation manual should be reviewed carefully before operation Keep this manual available for future reference and also for use in the orientation of new personnel If the scale becomes damaged it should not be operated until properly serviced All repairs should only be performed by authorized Healthometer Professional service personnel This scale is designed for static weighing of patients only No scale should be used for patient transfer Healthometer Professional Pelstar LLC assumes no responsibility for patient injury or scale damage should this caution be ignored Do not leave patients unattended while on the
6. Menu 01 WEIGHT DISPLAY MODE only applies to pound values NOT the metric values The user can set the screen display value in either fraction of pound 4 Y or Ib in pounds and ounces resolution of 4 ounces or in decimals resolution of 0 2 lb When kg is selected as the units of use these settings have no effect The mode that is selected is used through all the screens 01 14 2004 11 30pm 1852 b 01 14 2004 11 30pm 02 Pounds amp Ounces 1 85 1 2 03 Decimals LB OZ AV to change Enter 01 14 2004 11 30pm 189 01 Figure 9 Weight Display Mode 14 OPERATION INSTRUCTIONS 02 TARE WEIGHT NOTE Due to the scale s sensitivity we recommend using the REWEIGH function prior to setting the TARE weight in order to eliminate any operator interference with the item to be tared out There are two ways to manually enter a tare weight such as the weight of a stretcher shoes etc press MENU 1 and select option 02 Tare Weight or press TARE 9 If there is no weight on the scale platform value displayed is zero and there is no tare and the user presses the TARE button 9 the Tare Weight window appears and prompts the user to enter the TARE value and to press ENTER NOTE The tare weight must be entered using the following increments 40z 0 2lb alb The value entered will display in minus After the TARE has been entered the scale goes back to normal operation This TARE value is stored in memory until changed
7. W NC 3 8 16 1 3 4 41 208 2034701 0_ MAINBOARDTOCON DIGCABLE ____________ 1 Y 3809801 0 BEAMASSEMBLY 4 040 PHIL PAN HEAD SCREW NC6 32 1 4 12 SPACER WITH EX THREAD STUD NC6 1 4 l 48 SOCKET BUTTON HEAD CAP SCREW NC1 4 20 3 4 a po SAFETY WASHER NCS l 22 HEX SOCKET HEAD SHOULDER SCREW 5 16 3 8 1 26 HEX SOCKET HEAD CAP SCREW NC5 16 18 3 4 27 A CE AAN CA 314 PHIL PAN HEAD SCREW NC8 3 8 6 4 PHIL PAN HEAD SCREW NC6 32 3 8 __ _ _____ 2 38 INDICATOR COVER 1 O AA LCD WINDOW 40 LCD BOARD o o WIN1412 CROSS HEAD SCREW K22L6 4 a DISPLAYTOEAGLEP C BCABLE Z o Z o o 1 a WIN1412 CROSS HEAD SCREW K30L6 O Z o Z o O 4 a EAGLE BOARD O 1 O 45 0 INDICATORBASE 1 a po PHIL PAN HEAD SCREW NC6 32 3 8 Z Z 6 ar MODELLABEL 1 sa PHIL PAN HEAD SCREW NC4 40 1 4 o O 1 63855 PATIENTLIFT S O 21 WARRANTY LIMITED WARRANTY What does the Warranty Cover Pelstar LLC scales are warranted from date of purchase against defects of materials or in workmanship for a period of three 3 years If product fails to function properly return the product freight prepaid and properly packed to Pelstar See To Get Warranty Service below for instructions If manufacturer determines that a defect of material or in workmanship exists customers sole remedy will be repair or replacement of scale at no
8. YMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on Dead Battery Replace batteries Faulty electrical outlet Use a different outlet Bad power supply Replace adapter Questionable weight or External object Remove interfering object the scale does not zero interfering with the scale from the scale 2 The weight of the Take the patient and the stretcher as tare was not stretcher off the scale set correctly zero the scale hang the stretcher on the scale and enter the tare weight After the tare weight is set start weighing action 3 The patients center Take the patient off the mass is not at the center stretcher and re position of the stretcher and one so that the center mass of the hanging hooks of will lie between the two the lifter boom does not hoops lie on the lifter beam 4 Scale is out of calibration 4 Check weight with known weight value Weighing is performed but The patient is not still Ask the patient to be still or the display shows weigh change the scale to use the and reweigh every few live weight setting p 19 seconds the weighing process takes too long and no weight is displayed The display shows The load on the scale Remove the excess weight Overload message exceeds the capacity and use the scale according to 400 Lbs its limits The display shows The batteries are empty Replace batteries according to LOW BAT message instructions The display shows The
9. be displayed in pounds decimals fractions of a lb or Ib oz or in kilograms The scale features a folding stretcher for easy mobility and a display assembly stand The unit can be operated using its AC adapter or by 6 D cell batteries not included SCALE SPECIFICATIONS Capacity and Resolution 400 Lb x 0 2 Lb 4 lb 4 oz 181 Kg x 0 1 Kg Power Requirements Adapter 120VAC 6VDC 60Hz or 6 x D size batteries Environmental Operating temperatures 50 F to 95 F 10 C to 35 C Storage temperatures 30 F to 125 F 0 C to 50 C Humidity 85 Stretcher Dimensions Closed Fully extended Length 70 7 180 cm Length 70 180 cm Width 6 15 cm Width 29 75 cm Weight 16 5 Lb 7 5 Kg ASSEMBLY INSTRUCTIONS Before Assembly The Model 2000KL ProPlus Stretcher Scale is shipped disassembled in two 2 separate cartons Carefully inspect all cartons for shipping damage before unpacking If damage is found contact your shipper or Healthometer Professional immediately Claims must be filed with the shipper as soon as possible after receipt of the damaged package Remove each assembly from the carton and unwrap packing material carefully to prevent scratching the unit s parts It is recommended that two people perform the assembly The scale is shipped in two 2 separate cartons as follows A Large carton containing 1 Hydraulic pump assembly 1 Lifter mast 1 Base adjustment lever 1 Lifter base
10. charge Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value All parts including repaired and replaced parts are covered only for the original warranty period Who is Covered The original purchaser of the product must have proof of purchase to receive warranty service Pelstar dealers or retail stores selling Pelstar products do not have the right to alter or modify or any way change the terms and conditions of this warranty What is Excluded Your warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instruction abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may also have other rights that vary from country to country state to state province to province or jurisdiction to jurisdiction To get Warranty Service Make sure you keep your sales receipt or document showing proof of purchase Call 1 800 638 3722 or 1 708 598 9100 to receive a return authorization number Attach proof of purchase to your defective product along with your name address daytime telephone number and descr
11. cm increments use inches for weight in Ib cm for kg Press ENTER 4 Display will read the patient s BMI The scale offers you two options to manage your information to transfer download the values or to store them The first option automatically downloads transfers the value to your PC The second option stores the value in memory The maximum capacity of the scale is 270 files of different data gt 02 Store In memory 03 Do not store data v AV to change Enter 01 Auto Download Automatic Download is the default option and will transfer the value to the PC as soon as the patient steps off the scale or when the user presses the HOLD RELEASE button if it was Updated kept in HOLD If no PC is connected the value is not transferred and not stored and will be lost after the load is removed from the scale 02 Store in memory The value is stored in memory for later download to PC If the memory is close to full Updated the user will be warned and given the option to transfer all 02 Clear memory values to the PC or to clear Exit the memory of all values 03 Do not store data All the data will be cleared Updated 16 OPERATION INSTRUCTIONS 04 Transfer now All the values stored in memory are transferred to the PC and the scale memory is cleared of all values If the transfer was unsuccessful the values are kept in memory until successfully transferred or cleared 05 Clear memory All the valu
12. e recommend reweighing after the patient is lying still on the stretcher by pressing the REWEIGH button 2 After weight measurement is obtained and recorded lower the Stretcher and the patient to the bed Open the hydraulic pump control valve knob by turning it counterclockwise very slowly to control the descent 3 Guide the patient and Stretcher down onto the bed 11 OPERATION INSTRUCTIONS 4 Release the hanging loops from the lifter Note The scale is programmed to save the last setting chosen as well as the weight of the stretcher as tare weight This enables weighing a number of patients without having to re set the scale If a weight was added or reduced from the stretcher scale it is required to reset the tare weight Note To zero the scale by using the ZERO key take the stretcher off the lifter before pressing ZERO key Replace the stretcher after zeroing O Press ON OFF key to turn scale off 12 OPERATION INSTRUCTIONS HOLD Pro P l u s ONOFF Capacity 600 Ib x 2 lb 272 kg x 100g Figure 7 Keypad ITEM DESCRIPTION FUNCTION ON OFF POWER Turns scale ON and OFF CON ZERO Zeros the scale prior to weighing ma Holds the value of the weighed object on the display until HOLD RELEASE the button is pressed again to clear the value Also used to scroll down in the menu y REWEIGH Allows repeated weighing of the patient without stepping off the scale Gy KG LB button Toggles between kilograms or pounds
13. e the LB KG button please contact Technical Support at 1 800 638 3722 or 1 708 598 9100 We recommend the use of EVEREADY Energizer e2 batteries 10 OPERATION INSTRUCTIONS Preweighing the Stretcher 1 Make sure the scale is free of load nothing is hanging from it including the stretcher 2 Press the ON OFF button to turn the scale on 3 Wait until 000Lb00oz and ZERO on the left side of the display will appear The scale will remember the last amount that was tared so if the weight of the stretcher had previously been tared the scale will display a negative weight when it is turned on again Note The ZERO sign will show on the upper left side of the display only when the scale is free of load including the stretcher 4 If the weight of the stretcher is known enter the TARE value according to instructions in the Menu para 02 If the stretcher s weight is unknown place the stretcher only on the scale press REWEIGH Enter the Automatic TARE by pressing the TARE button Display will read 000Lb00oz Note Once the tare is set the TARE sign will appear in the upper right side of the display Placing Patient in Stretcher 1 After setting the stretcher s weight as tare take the stretcher off the lifter The display will now show a negative weight equivalent to the weight of the stretcher 2 Lay the stretcher on a bed or on any other stable surface you can use to lay the patient you wish to
14. es stored in memory will be cleared No av to change Enter 04 SCALE SETTINGS gt 02 Sleep Time 03 Auto Off Time w av to change Enter 04 Tone Volume j g IE_Mian Nate amp Tima JO LISP Dale amp IMIE IG Priamnla Backli hd p enla ee ee oe U5 L iSPla Y Da La Alo iL E i Iisplav i I dad ES sca p F 4 z PoE ed i LI a or ZI ILI GLSL Live Weight AO A al O ur t J EAI NF Se e a de i _ 01 Auto Hold Time The user can determine how long to display the weight reading once it is determined regardless of whether the patient remains on the platform The scale defaults to no Auto Hold Time The maximum setting is 20 seconds Hold Time 00 Seconds Enter 02 Sleep Time The user can set the time elapsed before the scale goes into the sleep mode The default is 1 minute When the scale goes into sleep mode STANDBY is displayed on the screen 1 00 Enter 17 OPERATION INSTRUCTIONS 03 Auto Off Time The user can determine how long the scale will operate before turning off automatically due to inactivity Default time is 10 minutes If the value is set to zero the auto off 10 minutes function is disabled Enter 04 Tone Volume There is an option to adjust the beeping tone of the scale This tone should sound when the scale has determined 2 the weight on the platform when a key is pressed after 02 Stable Weight the scale is turned on at the end of self
15. g message will be displayed Please press the button marked 1 you have 10 seconds Exit If after 10 seconds the requested command was not received the following message will be displayed If Ul Error Failure is UI Error displayed refer to qualified service personnel Failure 07 USER SETTINGS 02 Disp Height amp ID 03 Prompt For Height Vv Exit 01 Retain Entered Values This option allows the user to use the same values for ID height and TARE between weighing If this option is disabled the user has to re enter these values for each reading lf the Yes values are not entered only the weight is stored NOTE These values cannot be retained by ID number av to change Enter 21 OPERATION INSTRUCTIONS 02 Disp Height amp ID Yes Av to change Enter 01 14 2004 ZERO 01 14 2004 ZERO 11 30pm 94 4 Ib Height 6n00 0 0in ID 981723737123 11 30pm 53 4 Ib When this option is activated the user will be asked to enter the patients height after every weighing 03 Prompt For Height Yes Av to change Enter 04 Prompt For ID When this option is activated the user will be asked to enter the patients ID number after every weighing Yes av to change Enter 22 When the user selects to display the height and ID of the user it will be displayed at the bottom of the screen We recommend the use of this function to ensure that the patient s c
16. iption of the problem Carefully package the product and send with shipping and insurance prepaid to Pelstar LLC Attention R A Repair Department 7400 W 100th Place Bridgeview IL 60455 If your scale is not covered by warranty or has been damaged an estimate of repair costs or replacement costs will be provided to you for approval prior to servicing or replacing Pelstar LLC 7400 West 100th Place Bridgeview IL 60455 1 800 638 3722 or 1 708 598 9100 www healthometermedical com Health o meter ProPlus products are manufactured designed and owned by Pelstar LLC Health o meter is a registered trademark of Sunbeam Products Inc Boca Raton FL 33431 ProPlus is a trademark of Pelstar LLC Patents Pending 28
17. mbly onto the display support by inserting the two metal supports into the two slots in the rear display assembly Tuck the excess load cell cable in the Lifter Boom tube Note The load cell cable should now be secured in the channel between the display assembly and the display support 12 Insert 4 screws into the display support and tighten 13 Connect power cord to the power port in the display assembly and insert and secure the cable into the exposed portion of the 2nd channel from the left in the display 14 Insert the power cord into the retaining slot on the rear cover Align the rear cover tabs with the slots on the rear of the display assembly Apply pressure to snap the rear cover into place and secure with 2 screws ASSEMBLY INSTRUCTIONS LIFTER BOOM LOAD CELL CABLE LOAD CELL Q ASSEMBLY SAFETY WASHER NC3 8 e SHOULDER SCREW 3 8 NC 5 16 x1 STRETCHER HOOPS HANGING LOOPS STRECHER SHEET BARS JOINT Q o STRETCHER NN Sy igure 15 Hang the Load Cell Assembly on the two hooks at the end of the Lifter Boom using the loops on top of the Load Cell Assembly 16 Connect the end of the Load Cell Cable coming out of the center of the Load Cell Assembly to its port in the Lifter Boom 17 Use the two washers and shoulder screws to connect the two Stretcher Hoops to the Load Cell Assembly and tighten well 18 Connect the two right stretcher bars by screwing them onto one Stretcher Bar Co
18. nnector in order to make one long Stretcher Bar 19 Repeat step 9 with the left Stretcher Bar 20 Insert the two bars into the open side of the channel pockets in the Stretcher Sheet and through the two hanging loops sewn into both sides of the Stretcher The Stretcher Bars should not protrude from the Stretcher Sheet at either end Make sure one end on both channel pockets is sealed with Velcro Note Make sure the bars are inserted into the two hanging loops sewn on both sides of the stretcher This will ensure that the Stretcher Bars hang correctly from the hanging loops O SET UP Preparing the Scale for Use Remove protective plastic film from keypad and display Place batteries in the battery holder see Replacing Batteries Plug the scale s AC adapter into the power source Press the ON OFF button to turn the scale on The display will show Health o Meter Pro Plus and then 000LbOOoz If the Stretcher weight has previously been tared out the display will show a negative weight equivalent to the weight of the Stretcher O Hang the stretcher on the Stretcher Hoops to register a O weight on the display Press the Tare key if necessary 6 Place a weight not exceeding 400 Lb 180 Kg on the stretcher The display should read the correct weight 7 Press the KG LB button to select the weight mode Lb Kg 8 Press the Reweigh button the scale should perform the weighing process again The display sho
19. or cleared Important The TARE weight cannot exceed 125 Ib The number that is to be changed will flash and will move from the left to the right after the appropriate number was LB OZ entered or by using the 4 key left and the v key right Exit TARE display indicates the weight 01 14 2004 that has been tared j 05120 Figure 10 Tare Weight Automatic Tare The user can set a tare weight by pressing the TARE button 9 while there is a weight on the scale platform The display will come to zero and TARE will be displayed to indicate there is a tare value in the memory as displayed in Figure 10 above Removing the Tare Additional pressing of the TARE button will delete the tare value from memory TARE will disappear from the display and the scale will resume normal operation 03 DATA MANAGEMENT The scale manages patient data including patient ID weight height tare and BMI The value is stored in memory or transferred to PC This function is performed by opening a new data file OPENING A NEW DATA FILE 1 Press the ID button 7 2 Using the keypad type in the identification number 3 Press ENTER This scale will also calculate Body Mass Index BMI CALCULATING BMI 1 Place the patient on the scale platform 2 Press the BMI button 2 15 OPERATION INSTRUCTIONS 3 The scale will prompt you to enter the patient s height Use the keypad to enter the height in 1 4 1 1 4 2 1 2 3 3 4 or 1
20. orrect ID and height have been entered 01 14 2004 1534 b 11 30pm Please enter Height 0100 0 0in av to change Enter 01 14 2004 19371 Please enter ID 2345872336 Enter 11 30pm av to change MAINTENANCE GENERAL This section provides instructions for maintenance cleaning troubleshooting and operator replaceable parts for the ProPlus Stretcher Scale Model 2000KL Maintenance operations other than those described in this section should be performed by qualified service personnel MAINTENANCE Before first use and after periods of non use check the scale for proper operation and function If the scale does not operate correctly refer to qualified service personnel 1 Check overall appearance of the total scale for any obvious damage wear and tear 2 Inspect AC adapter for cord cracking or fraying or for broken or bent prongs CLEANING Proper care and cleaning is essential to ensure a long life of accurate and effective operation Disconnect the scale from the AC power source 1 Clean all external surfaces with a clean damp cloth or tissue Mild soap and water solution may be used Dry with a clean soft cloth 2 Do not immerse the scale into cleaning or other liquid solution 3 Do not use Isopropyl Alcohol or other solutions to clean the display surface 23 TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel S
21. p on the outside of the socket fits securely in the notched adjusting plate To adjust the base legs pull back on the adjusting lever to unlock Move the lever to the right to widen the base 7 A wheel lock is provided on the Lifter Base for parking only To lock caster step on cam lever on side of caster To unlock step on higher cam lever NOTE Never lock wheel lock or block wheels when lifting someone Wheel lock is provided for parking the Lifter only 8 Check the operation of the Hydraulic Pump by pumping the handle to elevate the Boom Make certain the control valve knob located on the pump near the handle is fully tightened clockwise 9 To lower the Boom slowly turn the control valve knob counterclockwise The rate of descent can be controlled by how much the knob is turned The Boom may not lower readily with weight To test simply apply downward force to the Boom Note If bolts mounting pump or Lifter Mast are too tight the Boom may not lower properly ASSEMBLY INSTRUCTIONS LOAD CELL CABLE DISPLAY ASSEMBLY BATTERY COVER Ta eh e O DISPLAY SUPPORT REAR COVER SCREWS 4 POWER CORD Figure 4 10 Position the Display Assembly close to the Display Support Connect the load cell cable connector to the load cell port on the rear of the Display Assembly and insert and secure the cable into the center channel in the display Note Do not attach the power cord at this point 11 Slide the display asse
22. re is a problem with one Check load cell cable Load Cell Error message or more load cells or the load connection at the display and cell cable is disconnected platform assembly ports If the problem is not corrected refer to qualified service personnel to replace the defective load cell 24 CALIBRATION PATH The calibration is performed in Kg or Lb according to the units of measure used upon entering into the calibration path Operator Action Display 1 Press ON OFF button and immediately press _ Calibration and hold HOLD RELEASE button for 3 4 Process seconds 2 Press ENTER Enter load weight 400 0 3 Using A v keys and or the keypad set the Zero calibration calibration load to at least 200 lbs for best Please clear the scale results and greater accuracy use a 400 Ib weight Press ENTER 4 Please clear the stretcher and press ENTER Please wait 5 Please wait without touching or shaking the Weight calibration scale until the zero calibration process Is finished 6 Load the stretcher with the required weight and press ENTER Please wait 7 Please wait without touching or shaking the scale until the calibration process is finished factor X XXXXX Please clear the scale Please wait Pro Plus 25 EXPLODED VIEW OF SCALE continue 26 PARTS LIST KeyNo _ PartNo ___ Descriptimn_________________________ Qty os yo o HEXHEADSCREWNC3 8 16 21 2__ o Z O 1 6 HEX HEAD SCRE
23. scale For accurate weighing the scale must be placed on a flat and stable surface with the locking screw locked properly and the weighing mechanism not touching the floor For accurate weighing verify proper operation according to the procedure described in this manual before each use Do not use in the presence of flammable materials Operating at other voltages and frequencies than specified could damage the equipment If the LOW BAT indicator activates for accurate weighing replace the batteries or connect the scale to an AC power source as soon as possible Failure to comply with the following will void scale warranty o Do not gas sterilize or autoclave the scale o Do not place liquids on top of the scale display console o Do not exceed recommended weigh limit of 400 lb 181kg for this scale o This scale contains delicate sensors Do not bang into doors elevators etc as damage may result SPECIFICATIONS GENERAL Health o meter s ProPlus Stretcher Scale Model 2000KL uses highly sophisticated microprocessor technology This scale is designed to provide accurate reliable and repeatable weight measurements and features that make the weighing process simple fast and convenient The scale is set up to use motion sensing weighing technology to determine the actual weight of a moving patient The scale may be changed to measure live weight see page 19 for instructions on changing the scale setting The weight can
24. test or in the case 03 Alarm Tone z of fault or warning av to change Enter Use the 4 and v keys on the keypad to adjust the volume Whenever the user presses the key to change a volume a beep will sound to indicate the set volume level av to change Enter 05 Display Date and Time This option will turn on or turn off the date and time display No av to change Enter 01 14 2004 11 30pm ZERO ZERO 000 002 0020002 18 OPERATION INSTRUCTIONS 06 Display Backlight The user can set the brightness of the backlight Av to change Enter 07 Display Contrast The user can set the brightness of the LCD av to change Enter 08 Live Weight By selecting Yes the user can set the Live Weight mode to deactivate the motion sensing mode In the Live Weight mode the weight displayed will fluctuate with the patient s No movement the scale will not lock on quickly to the weight as is the case in the motion sensing mode aAvtochange Enter Press the REWEIGH button to operate the motion sensing mode and to determine the correct weight on the screen To revert back to motion sensing mode change the Live Weight setting to No 05 SYSTEM SETTINGS 02 About v AV to change Enter 01 Set Time Date The user can set the time and date using the keypad To set the time move between hours minutes and seconds using the up and down keys 4 v and enter the values on the keypad To jump to the AM PM
25. uld read WEIGHING until the weight calculation is complete and the weight is displayed 9 Remove the weight from the stretcher the scale will return to zero and the display will read ZERO on the left upper side of the screen along with OOO0LbOOcz 10 Disconnect the scales AC adapter from the power source and the scale will switch to battery power PS Note If the set up procedure failed refer to the troubleshooting instructions If the problem is not corrected refer to qualified service personnel To adjust the display backlight and or contrast please refer to page 19 To change the display mode in pounds to fractions or decimals please refer to page 14 Replacing Batteries a b SCREW BATTERY COVER BATTERY HOLDER BATTERY HOLDER CABLE CONNECTOR Figure 6 Replacing Batteries refer to the Parts List on page 25 for details on parts followed by GH Unplug the scale Remove the battery cover from the display assembly Disconnect battery holder cable connector from the scale battery connector Carefully remove the battery holder by sliding it out of the display assembly Replace the batteries with new ones Carefully slide the battery holder into the display assembly Plug the battery holder cable connector to the scale battery connector Attach the battery cover to the display assembly and install the screw SoS PA To change the scale default units to kilograms or to deactivat
26. with casters B Small carton containing 1 Lifter boom 1 Stretcher storage tray 4 Stretcher bars 1 Display support 1 Adapter holder 2 Stretcher bar joint 1 Display assembly 1 AC adapter 1 Hexagon screw with lock nut 1 Load cell assembly 1 Display rear cover 2 Plastic washer 1 Velcro strap 2 Stretcher hoops 6 Screws for display 1 Stretcher sheet 2 Shoulder screw and washer Tools required Phillips head screwdriver adjustable wrenches 7 16 Allen wrench Parts of Stretcher Scale Lifter mast Hydraulic pump assembly Base adjustment lever Figure 1 ASSEMBLY INSTRUCTIONS Assembling the Patient Lifter 1 Place the Stretcher Storage Tray on the Lifter Base as shown below before attaching the Lifter Mast KNOB Figure 2 2 Remove black plastic protective caps from Lifter Mast Insert the bottom of the Lifter Mast and Hydraulic Pump assembly into the mast sleeve through the Stretcher Tray Holder on the Lifter Base The notch on the end of the mast fits over the round tube at the bottom of the Mast Sleeve The mast must lock into position in the mast sleeve making it impossible to rotate Check that the mast is locked into position and that the hole in the mast is aligned with the threaded hole in the mast sleeve 3 Insert the threaded locking device the plastic knob and stud chained to the base into the threaded hole in the mast sleeve Tighten to lock the mast to the base