Home

Generac 00941-3 Portable Generator User Manual

image

Contents

1. 27 94 4 H Serial Mfg No Please keep original or photocopy of your sales receipt with this manual for future reference should service ever be required INCLUDED IN THIS PACKAGE Manual 1 Warranty Information 2 Pre Installation Checklist to be reviewed prior to any assembly or installation 3 Necessary Adjustments 4 Programming Remote Devices 5 Maintenance and Troubleshooting 6 Parts Explosions 7 Accessory Order Form 8 Door Opener Association Safety and Maintenance Brochure DASMA 9 Entrapment Warning Label To be Adhered in close proximity to wall control Poster 1 Pictorial and step by step opener assembly instructions 2 Pictorial and step by step opener installation instructions IT IS CRITICAL THAT ALL SAFETY WARNINGS MARKED CLEARLY IN BOTH THE MANUAL AND POSTER ARE READ UNDERSTOOD AND FOLLOWED Visit Our Website at www geniecompany com FOR ANSWERS CALL 1 800 354 3643 SAVE THESE INSTRUCTIONS For Help call 1 800 35 GENIE or visit www geniecompany com OVERVIEW OF POTENTIAL HAZARDS Overhead doors are large heavy objects that move with the help of springs under high tension and electric motors Since moving objects springs under tension and electric motors can cause injuries your safety and the safety of others depend on you reading the information in this manual If you have questions or do not understand the information presented call The Genie Comp
2. 8 5 8 1 4 5 16 3 8 7 16 1 2 9 16 Sockets WARNING Hack Saw Wrench Use the Wall Console included with Opener Any other wall console can cause the Opener to operate unexpectedly and the light to stop working eB Le Ky Carpenter s Level Figure 8 Recommended Tools 6 For Help call 1 800 35 GENIE or visit www geniecompany com ADJUSTMENTS Set Limit SWITCHES AND Force CONTROLS Coarse Setting of Limit Switches A Setting Close Limit Switch Check that Carriage Assembly is disengaged With garage door fully closed slide Close Limit Switch until it is aligned with the center of the Carriage Assembly Tighten Set Screw Do Not over tighten B Setting Open Limit Switch Manually open garage door to full open position Slide Open Limit Switch until it is aligned with the center of the Carriage Assembly Tighten Set Screw Do not over tighten Re engage Carriage Assembly Setting Force Controls and Final Adjustment of Limit Switches A WARNING The garage door opens rapidly and can cause serious injury or death Keep the path clear Position the ladder to the side of the Power Head so it is clear of all moving parts of the Opener and the door Set the door Opener to use the minimum force needed to open the door A CLOSE ADJUSTMENT On front panel of Power Head find adjusting screw marked CLOSE Figure 9 e Gently turn screw counte
3. 4 Phillips Hex Head Screw 23 Straight Door Arm main box 1 yellow bag 4 24 _ Clevis Pin yellow bag 2 46 5 16 18 x 3 4 Hex Head Bolt 25 Cotter Pin yellow bag 2 orange bag 3 26 _ Curved Door Arm main box 1 47 _5 16 18 Hex Flange Nut orange bag 4 27 _3 8 16 x 7 8 H H Bolt yellow bag 2 48 Mounting Straps main box 2 28 3 8 16 Hex Flange Nut yellow bag 29 Wire main box 30 Insulated Staples red bag uy For Help call 1 800 35 GENIE or visit www geniecompany com Garage Door Opener Accessories Order Form D NI Formulaire de commande des accessoires pour ouvre porte de garage M j i How many q E For additional accessories not shown visit our website at www geniecompany com Comment pour les accessoires suppl mentaires pas montr visiter notr site web www geniecompany com beaucoup GICT 1 390 1 Button Compact Remote Allows remote operation of garage door To 1 Boutenner T l commande compacte Permettre op ration loign de porte de garage P N 36248R Ordering Instructions No C O D shipments Please include check or money order made payable to The Genie Company Do not send cash Allow 3 4 weeks for delivery 1 800 354 3643 Please have part number and credit card ready Mail Order Form to Genie Company 22790 Lake Park Blvd Alliance Ohio 44601 We accept Visa or Mastercard on phone orders only GIFT
4. Opener to accommodate an eight foot door N cessaire de prolongement du coulisseau Rallonge de prolongeant la course de l ouvre porte du conduit de chain pour une porte de 2 4 m 8 pi de hauteur COMMANDE TOTALE MANUTENTION ET EXP DITION TAXE DE VENTE TOTAL GLOBAL P N 35679R 32 00 GSX 8 Screw Driven Extension Kit An Extension to increase travel of a screw driven Operator to accommodate an eight foot door N cessaire de rallonge du Screw Drive Rallonge de prolongeant la coursede l ouvre porte pour une porte de 2 4 m 8 pi de hauteur GIRU 1T P N 35678R__ 32 00 60 WATT Enhanced Rough Service Light Bulb Ensures proper equipment compatability clairage de 60 WATT Garantir componant exact par syst me P N 26210A S 2 73 GER 2 Emergency Release Kit Provides access to garage from outside in the event of an electrical power failure SHIP ORDER TO EXP DIER MARCHANDISE POUR NAME NOM N cessaires de D clenchement de secours Le n cessaire de d clenchement de secours est con upour vous permettre d acc der votre garage depuis l ext rieur en cas de panne de courant et lorsqu il ADDRESS ADRESSE P N 35675R 20 00 CITY VILLE STATE TAT provide additional clearance and mounting options Crochets d adaptateur 2 Utilis conjointement avec STB standard monter ZIP PEODE ROI les crochets ils fournissent le d gagement suppl mentaire
5. at no cost to you for parts and labor but you will have to pay a minimum of 5 00 for shipping and handling charges Your choice of either one of the above described service options is your exclusive remedy under this warranty What this warranty does not cover This warranty does not cover batteries which are considered replaceable parts installation commercial use defects resulting from accidents damage while in transit to our service location or damage resulting from alterations misuse or abuse lack of proper maintenance unauthorized repair or modification of the product affixing of any attachment not provided with the product programming of the Remote Control Devices Safe T Beam adjustment cleaning staples through wiring pinched or broken wires Carriage disengaged Force Control adjustments door out of balance broken springs or cables power outages use of extension cords missing or damaged parts on discounted clearanced final sale or taped cartons phantom operations labor is not covered if Opener is functioning properly while technician is in garage fire flood or acts of God or other failure to follow the Owner s Manual Please note the following information so it is available if you need to call us Date Purchased I I Serial Number Operator Model Dealer Name Dealer Address City State Zip Serial Number is located on the Power Head inside the Light Cover WK YR P I
6. avec monter d options A STB Adapter Brackets 2 Used in conjunction with standard STB Brackets They 4 2 Prices subject to change without notice Les prix assujettissent pour changer sans la notification P N 34439R S 4 37 14 For Help call 1 800 35 GENIE or visit www geniecompany com
7. date and place of purchase of the product 1 Do It Yourself Service Call the Genie Customer Service toll free at 1 800 354 3643 to speak in person to a trained Genie representative for assistance in diagnosing the problem and arranging to supply you with the required parts for do it yourself repairs Trained service representatives are available Monday Friday 8 00 a m 9 00 p m Eastern Time and on Saturday 10 00 a m to 7 00 p m Eastern Time subject to holidays You may also get the information you need at www geniecompany com 2 Service From Authorized Dealers You also may obtain warranty service from Genie authorized dealers by calling the Genie Customer Service at 1 800 354 3643 or by visiting www geniecompany com before scheduling warranty service If warranty service is provided by an authorized dealer Genie will provide all required parts under warranty at no charge to you but the dealers are independent business people and may render a bench or service call charge for their services Genie will not reimburse you or otherwise be responsible for those charges We suggest that you retain your original packing material in the event we choose to repair or replace your Genie Product and request that you ship it to us Be sure to include your name address telephone number proof of date and place of purchase and a description of the operating problem After repairing or replacing your Genie product we will ship it to your home
8. e Determine source of interference Repeat Check for sunlight or another opener on nearby door e Contact Customer Service ON 4 BLINKS Pause ON Source not sending pulses e Contact Customer Service Repeat e Source defective e Contact Customer Service 10 For Help call 1 800 35 GENIE or visit www geniecompany com General Troubleshooting Opener does not run 1 Check Lock switch on Wall Control Installation Poster from Wall Control 2 Check Power Source e For Grounded Plug Connection Plug a lamp into the electrical outlet used for the door opener a If lamp lights power source is good b If lamp does not light check fuse or circuit breaker e For Permanent Wiring Connection Check fuse or circuit breaker Check connections see Wall Console Installation on Installation Poster At Power Head Terminals and Wall Control Door Opener starts Check Wires to ensure that they are not cut Staples can cut insulation and short Wires for no apparent reason Replace any shorting Staples and shorted Wires Was Remote Control lost or stolen If so erase all Remote Control codes from Receiver s memory and reprogram for remaining remote controls See Erase All Receiver Memory on page 8 Ensure that no Buttons are stuck pushed in on Wall Console or any Remote Controls Door starts down then Check Close Limit Switch setting page 7 and poster Adjust as needed stops before it is Check Force Setting pages 7 A
9. geniecompany com 11 PARTS IDENTIFICATION Power Heap Power Head Parts List emacs 1 Power Head Assembly Item Part Name 1 Power Head Assembly 1A Cover by Series Model 1B Front Panel Assembly 1D Motor Parts 1E Circuit Board Assembly 1F Capacitor By Series Model 1G Opto Wheel not shown 1H Carriage Slide 1J Chain 1K Circuit Board Bracket 1L Drive Module 1M_ Terminal Strip t ma a aa 3 3 4 3 1N No 8 32 x 3 4 Hex Head Screw w int Lockwasher 1P Shock Absorption Stop 1Q Motor Mount Bracket not shown 1X Chassis 4 1 4 20 Shoulder Bolt 5 1 4 Flange Nut 39 Coupler 41 No 8 32 x 3 8 Phillips Hex Head Screw 42 No 8 32 x 3 8 Phillips Pan Head Screw 1 48 Mounting Straps 2 49 Light Lens 1 Pre assembled Shut off power before opening the Cover Components inside Cover May Cause Electric Shock THERMAL PROTECTOR MOTOR CAPACITOR POWER HEAD TERMINALS ORANGE eT eg a WALL CONTROL YELLOW WALL STRIPED CONTROL POWER CORD OION O OOOOOHKHOOHOOH O SEQUENCER HOUSING SAFE T BEAMS STRIPED OPEN LIMIT OPEN ETEN LIMIT SWITCH LIGHT CLOSE CLOSE LIMIT LIMIT SWITCH 12 For Help call 1 800 35 GENIE or visit www genie
10. locallaws and regulations which may differ from United States and Canadian requirements prior to use Los transmisores cumplen con todas las reglamentaciones legales de los Estados Unidos y del Canada en la fecha de fabricaci n Ninguna garant a se da que cumplan con todas as reglamentaciones legales de ninguna otra jurisdicci n Si los transmisores se van a utilizar en otro pais el importador debe determinar si cumplen con las reglamentaciones y leyes locales que puedan ser diferentes a las reglamentaciones de los Estados Unidos y del Canada antes de usar los mismos Les metteurs sont conformes a la r glementation am ricaine et canadienne a compter de leur date de fabrication Aucune garantie n est stipul e indiquant qu ils sont conformes toutes les prescriptions juridiques d autres autorit s Si les metteurs sont utilis s dans d autres pays il incombe importateur d en d terminer leur conformit aux lois et r gles locales pouvant diff rer de celles des Etats Unis et du Canada avant toute utilisation desdits metteurs Sendeger te entsprechen allen gesetzlichen Bestimmungen in den USA und Kanada zum Zeitpunkt der Herstellung Wir bernehmen keine Gew hrleistung f r die Einhaltung aller gesetzlichen Bestimmungen in anderen Landern Sollen Sendegerate in anderen Landern eingesetzt werden so muss der Importeur vor dem Gebrauch sicherstellen dass die Sendegerate auch solchen lokalen Bestimmungen entsprechen welche
11. or any similar device Replace old Battery with new coin type battery e Replace back of remote B FOR FLASHLIGHT MODELS e Slide open battery cover Replace old Battery with new AAA battery e Replace battery cover A WARNING A moving garage door may cause serious injury or death e Keep people clear of opening while door is moving e Do not allow children to play with the Remote Controls If the Safety Reverse does not work properly Close the door and disconnect the Opener using the Emergency Release Cord e Do not use the door Opener Remote Controls or Wireless Keypad e Refer to the door and door Opener Owner s Manuals before attempting any repairs Remote Control Operation A Press Button on Remote Control Garage door will move B Press Button again Garage door will stop e The door automatically stops at the end of the open or close cycle C Press Button again Garage door will reverse Di Figure 11 1 Button and 3 Button Compact Remotes w Docking Station D There are several adanan varieties of remote connai available from your local dealer some equipped with a flashlight LS OC LEARN aos FORCE ean LOCATED UNDER THE LEARN LIGHT COVER CODE BUTTON Figure 12 Learn Code Button and Indicator Light Located Lower Right Corner Each Remote Control must be programmed separately The Remote Controls will not close the garage with malfunctioning
12. the Door Opener Failure to adjust the Opener for your installation properly may cause severe injury or death 1 Garage door frame reinforcement brackets screws bracing When possible use the Emergency Release only when the door or reinforcement kits dealer is Se caution when LE Release Ho oe ane ne Weak or broken springs are capable of increasing the rate of door i E nae i 15 se aapa is d nee closure and increasing the risk of severe injury or death ectrica outlet and or wiring supp ied by a licensed e ectrician KEEP GARAGE DOORS PROPERLY BALANCED See Owner s Sufficient angle iron or strapping for hanging Power Head store Manual An improperly balanced door increases the risk of severe 1 60 Watt light bulbs Rough service bulbs recommended store injury or death Have a Genie Factory Authorized Dealer make C GER 2 Emergency Release Kit for entry during power failure store repairs to cables spring assemblies and other hardware Wood for header ceiling and or door braces store 8 SAVETHESE INSTRUCTIONS o Masonry fasteners for Safe T Beam Bracket installation store C Safe T Beam Bracket Extensions dealer Masonry drill bit store NOTES REMINDERS 0 Extension Kit for 8 Garage Doors dealer Go to Assembly and Installation Poster for full Installation Instructions 1 16 5 32 Tape Measure 3 Drill Bit Drill Bit m p Phillips Screwdriver Stripper a Flat Blade Screwdriver Safety Glasses
13. 1 390 1 Button Flashlight Transmitter Remote Controller with a Flashlight 1 boutenner l metteur de lampe de poche Le contr leur loign avec de lampe de poche P N 35657R GICT 3 390 3 Button Compact Remote Allows remote operation of 3 garage doors 3 boutenner la T l commande compacte Permettre op ration loign Please add local sales tax if you reside in one of the states listed trois portes de garage P N 36223R GWC 2W Deluxe Wall Console Operates Garage Door Independent light control Security vacation lock La Console dse luxe de Mur Actionne la porte de garage Commande d clairage ind pendante Interrupteur de verrouillage de s curit California Connecticut Florida Georgia Illinois Indiana Maryland Massachusetts Michigan New Jersey New York Ohio Tennessee Virginia Wisconsin TOTAL ORDER SHIPPING amp HANDLING STATE SALES TAX GRAND TOTAL P N 35661R GWKPD Dual Frequency Wireless Keypad Operates Intellicode Garage Door Openers without Remote Control or key Syst me d ouvre porte de garage clavier sans fil Actionne les ouvre porte de garage avec Intellicode sans t l commande ni cl GLU 3 3 4 oz Screw Drive Lubricant Ensures proper equipment wear protection La onza 3 4 Lubricant de la vis Garantir componant exact par syst me d fense vers user P N 35218AS 5 00 GW 2 Universal Wall Button Provides additional convenient inside
14. HECK Door HEADER AREA The header is a heavily reinforced section of the wall just above the top of the garage door opening A Find vertical center line of door and header e Close door e Measure door width at top e Marka point at center of door and on header directly above door Draw a center line to connect points B Find Header Bracket mounting height Figure 4 Do not attach Header Bracket e Raise door watching top edge of door and stop door when its edge reaches its highest point e Measure distance H from top edge of door to floor For sectional doors add 2 1 2 to H Mark a point on center line Bottom of Header Bracket will be installed here For one piece doors add 6 to H Mark this point on center line Bottom of Header Bracket will be installed here SECTIONAL DOOR ONE PIECE DOOR D ei HEADER g AE HEADER f x T Figure4 Find Highest Point of Travel For Help call 1 800 35 GENIE or visit www geniecompany com For all types and styles of doors If the ceiling in your garage is so low that there is not at least a 3 space above the Header Bracket mounting point contact a Genie Factory Authorized Dealer If a door spring is in the way place the Header Bracket above the spring Do Not move the door spring A WARNING Door springs are under extremely high tension and should be handled ONLY by a trained professio
15. ORTANT INSTALLATION INSTRUCTIONS TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ AND FOLLOW ALL SAFETY INSTALLATION AND OPERATION INSTRUCTIONS If you have any questions or do not understand an instruction call your authorized Genie installation professional Do Not install operator on an improperly balanced door An improperly balanced door could cause severe injury Repairs and adjustments to cables spring assembly and other hardware must be made by a trained service person using proper tools and instructions Remove all ropes and disable all locks connected to the door before installing operator Install door operator 7 feet or more above the floor Mount the emergency release knob 6 feet above the floor Do Not connect the operator to the source of power until instructed to do so Locate the control button Within sight of door Ata minimum height of 5 feet so small children cannot reach it Away from all moving parts of the door Install the entrapment WARNING label next to the wall button or console Install the emergency release tag on or next to the emergency release The operator must reverse when the door contacts a 1 1 2 inch high object on the floor at the center of the doorway This is about the size of a 2 x 4 board laid flat For Help call 1 800 35 GENIE or visit www geniecompany com SAFETY FEATURES Safe T Beam STB Non Contact Reversing System Places an invisible beam ac
16. Operation and Maintenance Manual TABLE OF CONTENTS Warranty Information 2 Safety Information xcsccinds conwennncowws 3 Safety Features vc conesctvensronwewnneriens 3 Important Installation Instructions 3 Pre Installation Checklist 4 6 Adjustments ics touviorivadwnsanwhes 7 8 Programming the Remote Control 8 Installing lightbulb and lens 9 Scheduled Maintenance 10 Troubleshooting Guide 10 11 Wiring Diagram sssssssrsssssnessss 12 Parts Lists and Exploded Views 12 13 Accessories esse msneesnenshesses 14 CE VE ACPOWERED CHAIN DRIVEN GARAGE DOOR OPENER COMPLETE WITH INTELLICODE REMOTE CONTROL AND SERIESII ELECTRONICS For 7 6 Doors Extension Kit is available for 8 Doors Included Wall Control MUST be installed prior to Operation of this Garage Door Operator Safe T Beam Safety Reverse System Must be Installed and the Force Controls MUST be Properly Set to close door This Equipment meets or exceeds all Federal State and UL 325 Safety Requirements Having Difficulty Need Help Please call us 1 800 35 GENIE 354 3643 www geniecompany com Please have Model information ready when calling THE Genie Company LiMITED WARRANTY What is covered Any defect in material and product workmanship from personal normal household use in accordance with the Owner s Manual For how long MODEL 2020L Se
17. Safe T Beam System Program Remote Controls while at least 24 from Antenna Wire If the red Learn Indicator Light blinks rapidly programming stopped Restart programming Each Button on a multi button Remote Control is for a different Opener Cannot use more than one Button for same Opener A maximum of seven Remote Controls or Wireless Keypads can be stored into the Receiver at one time If a Remote Control becomes lost or if you want to delete a Remote Control or Wireless Keypad see To Erase All Receiver Memory For Help call 1 800 35 GENIE or visit www geniecompany com INSTALLATION OF LENS AND BULB A Install a light bulb 100 Watts or less not included into Light Socket Figure 14 e Rough service 130 Volt bulbs are recommended B Install Lens into slots in Motor Cover e Insert Bottom hinges into slots provided in metal front cover of Power Head e Flip Lens up and fasten with molded latches on lens Figure 14 Install Lens and Light bulb NOTES For Help call 1 800 35 GENIE or visit www geniecompany com Transmitter Compliance Statement Transmitters comply with all United States and Canadian legal requirements as of the date of manufacture No warranty is made that they comply with all legal requirements of any other jurisdiction If transmitters are to be used in another country the importer must determine compliance with any
18. any or your local Genie Distributor In this section and those that follow the words Danger Warning and Caution are used to emphasize important safety information The word DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in injury or property damage The word NOTE is used to indicate important steps to be followed or important considerations EFFECT PREVENTION WARNING Keep people clear of opening while door is moving Could result in death Do Not allow children to play with the door operator Or serious Injury Do Not operate a door that jams or one that has a broken spring POTENTIAL HAZARD 1 e Turn off power before removing operator cover WARNING Could result in death or serious injury moving parts e When replacing cover make sure wires are not pinched or near Operator must be properly grounded e Do Not try to remove repair or adjust springs or anything to WARNING Could result in death or serious injury which door spring parts are fastened such as wood blocks steel brackets cables or other like items Repairs and adjustments must be made by a trained door system technician using proper tools and instructions IMP
19. company com PARTS IDENTIFICATION Rail amp Attachments amp Attachments 2 Rail Assembly Parts List Item Part Name Parts List Item Part Name Number Included 1 Power Head Assembly main box 31 Wall Button red bag varies by 2 Rail Assembly 1 piece model 4 Rail Assembly 3 piece main box 32 Wall Console main box varies by 5 First Rail Section separate box _ model 6 _ Middle Rail Section separate box 33 6 x 1 1 4 pan head phillips screw ae by mode 3 End Bal blue bs Separate sen 34 Entrapment Warning Label manual 1 7 p 7 g 35 _ Safe T Beam Sensor main box 1 9 1 4 20 x 5 8 Hex Head Bolt blue bag 36 Safe T Beam Source main box 1 10_1 4 20 Hex Flange Nut blue bag 37_ Safe T BeaM Mounting Brackets 2 11__ Carriage Assembly main bag 1 38 Remote Controls main box varies by 12 Rail Strap blue bag 1 model 13 Limit Switch white wire blue bag 1 39 _ 8 32 x 1 Machine Screw green bag 2 14 Limit Switch brown wire blue bag 1 15 _ Release Cord green bag 1 40 Safety and Maintenance Guide manual 1 16 Release Knob green bag 1 41 Wire Clips varies by 17 Emergency Release Tag green bag 1 model 18 Header Bracket orange bag 1 42 1 4 20 x 3 4 Self drilling Screws 20 Door Bracket orange bag 1 orange bag 3 22 1 4 x 2 Lag Screw orange bag 8 44 10 16 x 1 1
20. der form pg 14 Safe T Beam Mounting Bracket Figure 7 Mounting _ Safe T Beam Components PPT RECOMMENDED TOOLS IMPORTANT Check step s SAFETY INSTRUCTIONS A Tools Figure 8 B Additional tools to make installation easier AWARN l N G e Slotted and phillips screw driver bits e Stud finder e Sheet metal cutting snips TO REDUCE THE RISK OF SEVERE INJURY OR DEATH Check Step 9 Step 9 sets EXISTING GARAGE READ AND FOLLOW ALL INSTRUCTIONS oor Locks Never let children ie or play with the Door Controls Keep Check that the garage door locks rope and T Handles are the Remote Control away from children removed from the garage door before starting the installation Always keep the moving door in sight and away from people and objects until the door is completely closed NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR A If your garage does not have a separate entry door it is highly recommended to install a Genie Emergency Release Kit GER 2 Emergency Release Kit lets you open the garage door NEVER GO UNDER A STOPPED PARTIALLY OPEN DOOR from outside if there is a power failure Please see Accessories Test Opener monthly The door MUST reverse on contact with Order Form on page 14 a 1 1 2 high object or a 2 x 4 board laid flat at the center of the wen on the floor After aa either the Force or the Limit Before going further get any items and tools if needed of travel retest
21. djust as needed completely closed Check for shorted wires Door starts down then If a new installation check Door Arm position stops and goes back up Check operation of Contact Reverse function Check Safe T Beam System for beam obstruction or misalignment of Lenses Check Safe T Beam System diagnostic code Check Close Force adjustment see Set Limit Switches and Force Controls on pages 7 Adjust as needed Check garage door for binding Door will only run closed Check Open Limit Switch for a short circuit and for proper wiring Check Open Force adjustment see Set Limit Switches and Force Controls on pages 7 Adjust as needed Check condition of garage door and door spring s WARNING If you suspect a problem with the garage door hardware or springs contact a Genie Factory Authorized Dealer for service or contact Customer Service at 1 800 35 GENIE Check Position of Lock Switch on Console Door will only run open Check Safe T Beam System as detailed in the Safe T Beam System Self diagnostic Troubleshooting Chart page 10 Check Close Limit Switch for a short circuit and for proper wiring Check Close Force adjustment see Set Limit Switches and Force Controls on pages 7 Adjust as needed Lights will not turn off Disconnect Wires connecting Pushbutton to Power Head see Pushbutton Installation on poster Check their condition and either replace or reconnect Until a replacement Wall Console ca
22. elease Carriage Assembly from Rail Assembly by pulling down on Emergency Release Knob Raise door manually 3 4 and verify that door stays at FCC AND IC CERTIFIED Mar eee enpage All devices comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received includ ing interference that may cause undesired operation When the door is 3 4 above the ground the door should stay open Slight movement is acceptable If the door moves too much contact a Genie Factory Authorized Dealer for service or call Customer Service at B As Needed 1 800 35 GENIE e Replace Light Bulb TROUBLESHOOTING GUIDE Safe T Beam System Self Diagnostic Troubleshooting Source Red LED Sensor Green LED Possible Problem Solution OFF OFF e Power Head not powered Check breakers fuses plugs e Wiring from Power Head bad Check wiring for obvious shorts e Wiring to Source missing or bad Check wiring OFF ON i e Power has been interrupted Remove power and reapply 2 BLINKS Pause Beam not aligned Check Source Sensor alignment Repeat Beam obstructed e Check for obstruction Sensor defective Contact Customer Service 2 BLINKS Pause e Wire to Sensor missing or bad Check wiring Repeat OFF Sensor defective Contact Customer Service 3 BLINKS Pause Sensor receiving interference
23. it of travel retest the Door Opener Failure to adjust the Opener properly may cause severe injury or death When possible use the Emergency Release only when the door is closed Use caution when using this Release with the door open Weak or broken springs are capable of increasing the rate of door closure and increasing the risk of severe injury or death KEEP GARAGE DOORS PROPERLY BALANCED See Owner s Manual An improperly balanced door increases the risk of severe injury or death Have a Genie Factory Authorized Dealer make repairs to cables spring assemblies and other hardware SAVE THESE INSTRUCTIONS SCHEDULED MAINTENANCE Reattach Carriage Assembly to Rail Assembly a Pull the Emergency Release Knob toward A Monthly Power Head e Door springs and door hardware b Close door Oil door roller bearings and hinges using silicone lubricant or light oil AWARNING Contact Reverse Test Perform Adjustment Step 2 on page 8 AWARNING Do not operate door automatically or manually if springs If the door fails to reverse on contact with the board are broken Contact a Genie Factory Authorized Dealer for adjust the Close Force Control as specified in Set Limit service or call Customer Service at 1 800 35 GENIE Switches and Force Controls on page 9 If the Opener still Balance Door fails contact a Genie Factory Authorized Dealer for service Close door or call Customer Service at 1 800 35 GENIE R
24. ll moving parts of the Opener and the door Set the door Opener to use the minimum force needed to open the door B OPEN ADJUSTMENT e On front panel of Power Head find adjusting screw marked OPEN Figure 9 e Gently turn screw counterclockwise until it stops Very little force is required to turn adjusting screw e Press Wall Console to open garage door Observe if door stops at OPEN limit switch If door is fully open adjustment is finished If door stops but is not fully open a Measure distance between bottom of door and top of door opening b Move OPEN Limit Switch that same distance toward Power Head If door stops before reaching the OPEN Limit Switch a Slightly increase OPEN Force setting clockwise If door fails to move see Troubleshooting Section pages 10 amp 11 C Run Door Opener e Cycle opener a few times to double check settings Repeat adjustment steps as necessary OPEN FORCE LOCATED UNDER LIGHT COVER CLOSE FORCE CLASS 2 SUPPLY 18 30 VOLTS Figure 9 Making Force Adjustments Located Lower Right Corner Apwsrmenr 2 SETTING CONTACT REVERSE FUNCTION Limit Switch and Force Adjustments must be completed before checking the contact reverse function A Open garage door using Wall Console B Lay a 2 x 4 board flat in center of doorway Figure 10 C Close door using Wall Console D Check that door stops and
25. n be obtained disconnect Wall Console and use only Remote Controls or Wireless Keypad to operate Opener Check for non compatible wall control Door starts up Check ensure that garage door and Opener are in good repair properly lubricated and properly but stops before it is balanced as detailed in Maintenance Section completely open WARNING If you suspect a problem with the garage door hardware or springs contact a Genie Factory Authorized Dealer for service or contact Customer Service at 1 800 35 GENIE Check Open Limit Switch for a short circuit and for proper wiring Check Open Force adjustment see Set Limit Switches and Force Controls on pages 7 Adjust as needed Operator runs but door Ensure Carriage Assembly is engaged to Carriage Slide see Install Carriage Assembly onto Rails on Installation Poster does not move Check Force adjustment see Set Limit Switches and Force Controls on pages 9 and 10 Adjust as needed Wall Console Vacation Ensure Carriage Assembly is in contact with Close Limit Switch Lock function does Check when door is fully closed that Carriage activates Close Limit Switch If not adjust position of Close not work Limit Switch See pages 7 Noisy Operation Be sure all fasteners are tight Check ensure that garage door and Opener are in good repair properly lubricated and properly balanced as described in Maintenance Section page 10 For Help call 1 800 35 GENIE or visit www
26. nal C Check wall for a stud or a solid header at your mark If checking a finished wall a stud finder may be helpful e If location is above Header a 2 x 6 board must be screwed to studs beside your mark with at least two Lag Screws and Flat Washers not provided e Transfer your mark to new mounting board Check Step 5 CHECK Power Heap MounrTiNG AREA Check ceiling or space above where Opener Power Head will be mounted Figure 5 There must be a 120 Volt grounded outlet or wiring box within 3 feet of Power Head Grounded outlet Door Center Line Figure 5 Check Power Head location A The measurements above are taken from the garage door centerline toward the rear of the garage B Find location of ceiling joist or truss above where Opener Power Head will be and estimate type and quantity of materials needed for your installation Figure 6A amp B MOUNTING EXAMPLES Standard Straps Extra wood required Perforated Angle Iron Figure 6A OPEN CEILINGS Straps and angle iron may attach directly to joists or trusses For Help call 1 800 35 GENIE or visit www geniecompany com Perforated Straps FINISHED CEILINGS Locate ceiling joists or trusses using a stud finder or similar device Attach angle iron not included to joists or trusses through finish material using Lag Screws Figure 6B Mounting methods for open beam or finished ceilings Check Step 6 S
27. onnection to door s top and bottom beams Figure 1 A If door frame is nailed together and not a solid connection door frame must be braced or reinforced before installing Opener B If door is lightweight made with frame and skin not solid door including door frame must be braced or reinforced before installing Opener C A door opener reinforcement bracket may also be needed to connect garage door to Opener s Door Bracket This Opener is designed for installation on a properly braced sectional door or solidly braced one piece door D Contact your Genie Factory Authorized Dealer or dealer of your garage door for any necessary bracing and a door opener reinforcement bracket if needed before proceeding E Ifyou have a wooden door measure door s thickness If your door is less than 2 thick brace door or use shorter Door Bracket Lag Screws 1 4 x 1 1 4 not included Check Step 2 CHECK GARAGE Door ALIGNMENT OPERATION AND BALANCE A Raise door check alignment and see if it moves freely Figure 2 If door appears out of alignment binds or does not move smoothly contact a Genie Factory Authorized Dealer or dealer of your garage door for repairs and adjustments to door mechanism B Raise door to 3 4 above ground and carefully let go Door should stay stationary Slight movement is acceptable More than slight movement means door is out of balance Contact a Genie Factory Authorized Dealer or dealer of
28. operation of door i Instructions Commandant Pas d exp dition contre remboursement Veuillez inclure un ch que ou un mandat bancaire le payable fait The Genie Company N envoyez pas d argent comptant Accordez de 3 4 semaines pour la livraison 1 800 354 3643 Ayez sous la main le num ro de la pi ce et celui de la carte de cr dit Mettre la poste le arrngement Genie Company 22790 Lake Park Blvd Alliance Ohio 44601 Nous acceptons les commandes par t l phone avec paiement par carte de cr dit Visa ou Mastercard Bouton mural universel Actionne l ouvre porte de l int rieur du garage P N 35693R 3 75 GPS 5 Perfect Stop Ensures perfect parking Butoir Perfect Stop Permet de stationner a la perfection dans le garage P N 35677R 4 00 GABX8 Belt Drive Extension Kit An Extension that increases the travel of a belt driven Opener to accommodate an eight foot door r N cessaire de prolongement du coulisseau Rallonge de prolongeant la course de l ouvre porte Ed Belt Drive pour une porte de 2 4 m 8 pi de hauteur s Veuillez indiquer les taxes de vente locales si vous r sidez dans l un des tats r pertori s ci dessous California Connecticut Florida Georgia Illinois Indiana Maryland Massachusetts Michigan New Jersey New York Ohio Tennessee Virginia Wisconsin P N 35663R__ 32 00 LCGX 8 Chain Drive Extension Kit An Extension that increases the travel of a Chain Driven
29. rclockwise until it stops Very little force is required to turn adjusting screw e Press Wall Console to close garage door Observe if door stops at CLOSE limit switch If door is fully closed adjustment is finished Go to OPEN Adjustment If door stops but is not fully closed a Measure distance between bottom of door and floor b Move CLOSE Limit Switch that same distance toward door If door stops and or reverses before reaching the CLOSE Limit Switch a Slightly increase CLOSE Force setting clockwise If door reverses after contacting floor move Limit Switch toward Power Head If door fails to move check Safe T Beam System See Troubleshooting Section pages 10 and 11 Little effort is required to turn the Force Adjusting Knobs If the door stops moving while opening or closing adjust the Open Force or Close Force Controls slightly clockwise to slightly increase the force and retry the step The Open Force and Close Force Controls are to be set to the minimum force necessary to ensure the door smoothly opens and closes completely Ensure the Carriage Assembly is engaged and is between the two Limit Switches before operating the Opener For Help call 1 800 35 GENIE or visit www geniecompany com WARNING The garage door opens rapidly and can cause serious injury or death Keep the path clear Position the ladder to the side of the Power Head so it is clear of a
30. reverses within 2 seconds after it contacts board f door does not reverse decrease Close Force until door reverses Figure 9 e If door still does not reverse move Limit Switch toward door E Check Safe T Beam System operation e If beam is blocked door will not close Figure 10 Checking Contact 2 x 4 board Reverse laid flat The door must contact the 2 x 4 board before the Carriage activates the Close Limit Switch If not readjust the Close Limit Switch ACCESSORIES Programming 1 PROGRAMMING THE REMOTE CONTROL A Is program one Button of a Remote Control Figure 11 Locate Learn Button and Learn Indicator Light near Terminal Block on Power Head Figure 12 e Press and release Learn Button Red Learn Indicator Light will blink 2 times per second e Press Remote Control Button once within 30 seconds Red Learn Indicator Light will stay lit e Press Remote Control Button again Red Learn Indicator Light will go out indicating that memory is stored e Press again to Activate Unit B Program each additional Remote using step A above To Erase All Remotes from Power Head Memory A Press and hold Learn Button on Power Head for 10 seconds or until Learn Indicator Light goes out Memory is erased e Program Remotes again as needed To Replace Remote Control Battery A FOR NON FLASHLIGHT MODELS e Pop off the back of the transmitter Use coin pen screwdriver
31. ries 10 years on motor and 2 years on all other parts Who gets the warranty This warranty is limited to the consumer who originally purchased the product Geographic scope This warranty applies only to units installed and operated within the country where they were purchased Limitations IMPLIED WARRANTIES INCLUDING THOSE OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY AN UNWRITTEN WARRANTY THAT THE PRODUCT IS FIT FOR ORDINARY USE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE GENIE WILL NOT PAY FOR LOSS OF TIME INCONVENIENCE LOSS OF USE OF YOUR GENIE PRODUCT OR PROPERTY DAMAGE CAUSED BY YOUR GENIE PRODUCT OR ITS FAILURE TO WORK ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES RESULTING FROM MISUSE OR MODIFICATION OF YOUR GENIE PRODUCT Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty is the only one we will give on your Genie product and it sets forth all our responsibilities regarding your Genie product There are no other express warranties State and province rights This warranty gives you specific legal rights and you may also have other rights which vary from state to state and province to province How to get warranty service To obtain warranty service for your Genie product you must provide proof of the
32. ross door opening that reverses the door during down travel to the fully open position if anything passes through beam Safe T Reverse Contact Reversing System Automatically stops and reverses a closing door within 2 seconds of contact with an object Safe T Stop Timed Reversed System Automatically opens a closing door if door does not close within 30 seconds ForceGuard Control Used to set the force required for opening and clos ing door For maximum safety set the minimum force required to fully open and close door Automatic Lighting System Light bulbs up to 60 Watts max used for safer entries and exits The lights turn on when door is activated and automatically turn off 4 5 minutes later Manual Emergency Release Allows the garage door to be opened or closed manually for emergencies or maintenance PRE INSTALLATION CHECKLIST This Opener includes parts and supplies needed to install in most garages and connect to most garage doors There are many variations of garages and garage doors A few additional parts and supplies may be needed to install Opener into your garage and connect to your garage door While checking items listed below note any additional items you will need Tools used in this section e 12 Tape Measure Pencil Ladder Level Check following items before assembling Opener Check Step 1 CHEck Door ConpiTION AND THICKNESS Check condition of vertical stile in center of door and its c
33. tep 6 CHECK CEILING FOR GROUNDED POWER SOURCE A Check that there is a 15 Amp 120 Volt grounded electrical outlet or grounded permanent wiring box per building code within 3 of Opener Power Head Figure 5 e If not an outlet or wiring box must be installed Contact a licensed electrician for installation e If building codes require permanent wiring Power Head must be partially disassembled to install appropriate wiring in place of Power Cord See Assembly and Installation Poster Permanent wiring must be installed by a Licensed Electrician Not all Genie Factory Authorized Dealers are Licensed Electrician s Contact someone who is a Licensed Electrician WARNING Do not use and extension cord Extension cords can cause dangerous overheating conditions Do Not use portable generators This product is designed to operate on standard house current Do Not use alternate power supplies Check Step 7 CHECK SAFE T BEAM M OUNTING BRACKET LOCATION Check for wood garage frame jamb or masonry at mounting location 6 above floor with attachment tabs facing away from garage door Figure 7 A If you cannot mount Safe T Beam Mounting Bracket to wood frame Concrete screws and concrete anchors not included must be used to mount Brackets on masonry with attachment tabs facing away from garage door Safe T Beam Mounting Bracket Extensions may be used not included available at Dealer or use or
34. von den Bestimmungen der USA und Kanadas abweichen BUE TF HNE H HA te oh Ae A Fal 70 DOSE A AY AT AS ERER o TIRE BPR RTA IEE SA KAT AR ESR SI Re MIRO BBE EIA eA EO PAA EE MBER EGS 5 BAIS K ARTEZA FSA MMR lle hFVASv Felts G HOT XU 9 REMY DIED UF EPL LEDS LALANS KFL AZ VI MWYAVAGRARONF PUS OI DIEM BENET 2 D GDL URRE CE RGA KGL AST yY WFR RERO A HYADEN NAA ER m OEA IK FEN DHA ffl DS TALS DH ZX CRIES LEE 2720 hf et E Eh DSA E OD ZAR fil HE PAL JB LL ER BLAH EA SEMAINES S4 FHL AAA AE SEES BI7lSHOF OH RPAH LEO FE Ch 21E CHE HEH BE HAC Q AAI HEH SH HQE USUCE BA EMA ole SO 71E CH ASA APS aS SS SUYAR ARS S101 SHA Qu FHL Pepe 2 TAHE CHRIS BEE 7 AIS Ha EAH eop SEALS O RE AH ELITE IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ AND FOLLOW ALL INSTRUCTIONS Never let children operate or play with the Door Controls Keep the Remote Control away from children Always keep the Por door in sight and away from people and objects until the door is completely closed NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR NEVER GO UNDER A STOPPED PARTIALLY OPEN DOOR Test Opener monthly The door MUST reverse on contact with a 1 1 2 high object or a 2 x 4 board laid flat at the center of the doorway on the floor After adjusting either the Force or the Lim
35. your garage door for repairs and adjustments to door mechanism KEEP FEET CLEAR OF DOOR Sectional Door Door Figure 2 Checking door balance AMWARNING If your door sticks binds or is out of balance have it adjusted by a Genie Factory Authorized Dealer Door springs cables pulleys brackets and associated hardware are under extreme tension and can cause serious injury or death C Check door type Make a note of whether it is a sectional or a one piece door for reference later Figure 2 SECTIONAL DOOR TORSION SPRINGS SECTIONAL DOOR EXTENSION SPRINGS ONE PIECE DOOR TRACKLESS Y Torsion Extension Springs TE Center Stile Header Area Center Stile N Figure 1 Note Door Type Check Step 3 Measure GARAGE Door HEIGHT A Measure door height floor to top of door using a tape measure B This new Garage Door Opener is designed for doors up to and including 7 6 tall If door height is 7 6 or less continue to Check Step 4 C If door height is 8 0 you need a Rail Extension Kit Figure 3 See Accessories Order Form Page 16 D Ifthe door height is taller than 8 0 the opener you purchased is the wrong version Contact your Customer Service Representative at 1 800 354 3643 Rail Extension for 8 door Figure 3 Rail Extension Kit TA ETES C

Download Pdf Manuals

image

Related Search

Related Contents

none 85014 Instructions / Assembly    Istruzioni per l`uso PROPHYflex perio tip Starter Set - 1.010  User Manual - Universal Robots Support  SBS CO9A20550  修理-お取り扱い =消耗品や部品ご購入 / , =・・ ` などのご相談は、 まずお  Manuel de codage  ION Audio Block Rocker Bluetooth  USER MANUAL  Bedienungsanleitung THR9  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.