1. B Digital Time Switch SPECIFICATIONS Input Voltage 120 VAC 208 240 VAC or 277 VAC in all units based upon dipswitch configuration 15252 NEMA 3R Indoor amp Outdoor BM A301US5 02 15253 15251 NEMA1 Indoor BM A301US5 12 15250 NEMA 3R Indoor amp Outdoor EM A301US9 02 Switch Rating DPDT Models Normally Open Contacts 4OA Resistive 120 277Vac 30A General Purpose 120 277Vac 20A Resistive 30Vdc 1 HP 120Vac 2HP 240Vac 20A Ballast 120 277Vac 15A Tungsten 120Vac 800VA Pilot Duty 120Vac 720VA Pilot Duty 240Vac TV 5 120Vac Normally Closed Contacts 30A Resistive 120 277Vac 15A General Purpose 120 277Vac 15A Resistive 30Vdc 20A Ballast 120 277Vac 1 4HP 120Vac 1 2HP 208 240Vac 290VA Pilot 120Vac 360VA Pilot 208 240Vac NOTE If loads are connected to both NC and NO contacts both contacts are derated to 67 of the above values ENVIRONMENTAL RATINGS Ambient Temperature 40F to 130F Humidity 0 95 RH Non condensing WIRING CONNECTIONS Screw clamp terminals for up to 2 AWG 8 wires per position For supply connections use 8AWG or larger wires suitable for at least 105 C Use copper conductors only LIGHTS Power LED Orange Light illuminates when power is applied to the timer Status LED Green Light illuminates when power is applied to load INSTALLATION CAUTION Before wiring or service power to this time switch and the equipment it controls must be turned off Turning off the ti
2. panel by prying out with a thin blade at the top Select knockouts to be used Remove the inner 1 2 knockout by inserting a screwdriver in the slot and carefully punch knockout loose Remove slug If the 3 4 knockout is required remove the outer ring with pliers after removing the 1 2 knockout Smooth edges with knife if necessary 2 Place enclosure in desired mounting location and mark the three mounting holes Drill holes for 10 screws start screws in holes Place enclosure over screws and tighten screws 5 Connect conduit hubs to conduit before connecting the hubs to the enclosure After inserting hubs into enclosure carefully tighten hub lock nut Do not over tighten 6 Install in accordance with all applicable National and Local code requirements See Figure 1 and wiring diagrams 7 Replace interior cover panel and 2 screws ee GROUNDING This enclosure is of plastic construction and does not require a ground connection and does not require bonding in pool applications This enclosure does not provide grounding between conduits When using non metallic conduit or cable connect the ground wires of all cables together with a wire nut When metallic conduit is used use grounding type bushings and a jumper wire between each conduit 75 C INSTOAD H a MOTOR GLE PHASE 3PHASE FIGURE 1 Typical Wiring Diagrams SPDT Timer and Load Same Voltage Wired as Single Throw Timer and Load Different Voltag
3. ck button to return to the main display 1 2 2 21 2 3 N A f 5 PRESSURE PLATE TERMINAL SCREW MAKE SURE WIRE INSULATION CLEARS PRESSURE PLATE Typical Wiring Diagrams DPDT 120V Timer 200 240 277V Load Double Break Wired as Single Throw Ra H TIMERN CN 9 COM NC2 NO2 COM2 120V Timer 120V Load and 24V Load Wired as Single Throw H 200 240 277V Timer 200 240 277V Load Double Break Wired as Single Throw R_i LCD Reset Function Figures H E i Clock Hours Setting hl Current Time Setting M Timer Minutes Setting 9 Programs Setting Ba S Override Manual ON OFF Switched Multiple Weekday Groups Apart from individual week days pressing the Day button also selects multiple day combinations such as Monday thru Friday Saturday amp Sunday Monday thru Saturday Monday amp Wednesday amp Friday Tuesday amp Thursday amp Saturday Monday thru Wednesday Thursday thru Saturday Monday thru Sunday After setting a single day or a multi day combination the programmed timer settings will be carried out on each of the week days at the same time Programming Countdown Operation 1 Press the Timer button to scroll through the 9 events settings to get to the ON C setting 2 Press the Override button to select whether the timer will turn ON or OFF during teh countdown period 3 Press the H and M butt
4. d H buttons at the same time The display will show the TIMER symbol blinking The random feature is now activated 2 Toturn the random feature off repeat step 1 Summer Time Feature DST Press the H and M buttons for 3 seconds to advance the current time 1 hour SUMMER should appear on the display Repeating this process will decrease the time by 1 hour and the SUMMER will disappear Power Back Up Feature In the event of a power failure the timer will retain its settings for an estimated 3 months assuming the power back up is fully charged Button Lock This function allows the user to lock the buttons so that they are not accidentally pressed 1 Press and HOLD the Clock button for more than 5 seconds An icon will appear on the display The buttons are now locked 2 To unlock the buttons repeat this step Note Flashing the timer is in the manual mode with key lock Not flashing the timer is in the timer mode with key lock sagan a Programmed Setting Skip a Setting Press the Timer button to scroll to the setting that needs to be skipped 3 Press the Override button to lockout the time setting The display will display H I d E and lock the hours and minutes setting 3 Press the Override button again to recall the setting time Will not work for Lockout Countdown feature
5. e Wired as Single Throw Q S dk 1296001 TIMERN CN Oc OM 120V Two Speed Fan Wired as Double Throw Field Wiring Timer Intenab Wiring OPERATING INSTRUCTIONS BASIC SETTINGS l Set Up Push the R button before programming to clear out any settings Once the R button is pressed the screen will begin to flash A paperclip may be needed for this step If the R button appears to stick down use a toothpick to maneuver it until it pops back up The screen will flash if the button is popped up successfully 2 Press the Clock button and the screen will stop flashing and be ready for programming o the Current Time Press and Hold the Clock button during the entire setting Press the H button to set the hours Press the M button to set the minutes Press the Day button to set the day of the week Release the Clock button i ee ae aa one ON OFF Settings Press the Timer button once and the TIMER 1 ON appears j Press the H and M button to set the hours and minutes to the desired time 3 Press the Day button to select the day s the setting will be active Refer to the Multiple Weekday Group below to see the available settings 4 Press the Timer button to store the setting and proceed to the next setting TIMER 1 OFF 5 Repeat for all remaining setting options 9 Total ON OFF settings Once completed press the Clo
6. mer switch only will not prevent a shock hazard Replace cover plate within housing before supplying power to time switch Installation should be performed by a licensed electrician only Before installing this product read all instructions carefully Remove protective cover panel within time switch housing by removing screws located above timer face and at the bottom of the cover panel 15250 Indoor Outdoor NEMA 3R Rated Enclosure DIPSWITCH CONFIGURATION WARNING Failure to properly configure the dipswitch will result in damage to the unit and void the warranty Before installing and wiring the GE Time Switch proper configuration must be selected This is accomplished as follows INPUT VOLTAGE DIP SWITCH SETTING 1 Do not apply power to the timer prior to setting correct Input Voltage DIP switch 2 Determine the input voltage which will be applied to the timer i e L1 and L2 N terminals see wiring diagrams 3 Set the DIP switch according to the diagram below 120VAC 208 240VAC 277VAC Default NOTE Unit is shipped with DIP switches set for 277VAC Input Voltage CAUTION Do not check circuits by sparking wires to terminals Damage to the timer may result NOTE For outdoor locations model GE 15252 rain tight or wet location conduit hubs that comply with requirements of UL 514B standard for fittings for conduit and outlet boxes must be used 1 Remove 2 screws retaining the interior cover panel and remove
7. ons to set the hours and minutes of the countdown 4 Press the Clock button to store the setting and return to the current time display See the diagram below for more information ADVANCED SETTINGS Activate the Countdown Feature 1 Press the Clock and Override button at the same time to start the countdown function 2 Press the Override button to pause and continue the countdown function 3 Press the Clock button to go view the current time display Manual Override The timer comes with the ability to control the ON and OFF function while the timer is deactivated Press and Hold the Override button to switch between timer mode and manual mode Timer mode will be indicated by an A next to the ON or OFF When the timer is in manual mode not controlled by timer the A will not appear on the display Any time the A is on the display the timer is in control and will always follow the programmed settings even if it is temporarily deactivated by moving from ON to OFF or OFF to ON Random ON OFF Setting This feature allows the timer to switch ON and OFF at random times It is particularly useful in helping to prevent house burglary as the timer is not switching ON and OFF at regular times The programmed settings set will be executed in a random delay varying within 30 minutes This function will only operate If one or more programmed switching commands are set 1 Press both Day an