Fujitsu C141-E252-01EN Computer Drive User Manual

image

Contents

1. Operating system documentation Information files in your operating system 1 3 Performance features Customer Self Service CSS The PRIMERGY Customer Self Service CSS concept enables you to identify and replace the affected component yourself in the case of certain error scenarios In the CSS concept you can replace the following components yourself in the event of an error Hot plug hard disk drives only with an attached storage blade like SX940 S1 Memory modules Expansion cards For information on replacing these components see chapter Replacing CSS components on page 59 CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises for more information on the behavior of these indicators see chapter Installation and operation on page 41 and the ServerView Suite Local Service Concept LSC manual on the ServerView Suite DVD 2 You can also fit your server with a ServerView Local Service Panel which enables you to identify the type of component affected by the error directly on the server for more information see the ServerView Suite Local Service Concept LSC manual on the ServerView Suite DVD 2 In addition CSS errors are displayed in the ServerView Operations Manager the server management software from Fujitsu BX960 S1 Operating Manual 11 Performance features In the event of errors the ServerView Opera
2. cO Operating Manual English FUJITSU PRIMERGY BX960 S1 Server Blade Operating Manual May 2011 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Feel free to send us your comments by e mail to email manuals ts fujitsu com Certified documentation according to DIN EN ISO 9001 2008 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2008 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2011 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trade names and or trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu Microsoft Windows Windows Server and Hyper V are trademarks or registered tradema
3. gt First read the chapter Important notes from page 23 particularly the section Safety instructions gt Unpack the Server Blade check the contents of the package for visible transport damage and check whether the items delivered correspond to the details on the delivery note see section Unpacking the server on page 34 gt Transport the server blade to the place where you want to set it up gt Make sure that you have all necessary manuals see page 11 print out the PDF files if required gt Install the server blade in your BX900 S1 system unit see section 4 2 on page 34 gt Familiarize yourself with the controls and indicators on the front of the server blade see Control and display elements on page 41 gt Install the operating system and applications on the server blade When doing so you have the following options Clone the server blade from a remote image server using the ServerView Deployment Manager Cloning the ServerView Deployment Manager from a remote image server This procedure is recommended if the following conditions are met ServerView Deployment Manager software is available You have a suitable clone image A Deployment Server and LAN connection are available Remote installation with ServerView Installation Manager This installation method is recommended if you have a LAN connection and a DHCP server Deployment Server available but the cloning requirements
4. gt Insert the DVD for the operating system you want to install gt Reboot the server blade gt Follow the instructions on screen and in the manual for the operating system 48 Operating Manual BX960 S1 Cleaning the Server Blade 5 4 Cleaning the Server Blade CAUTION Switch off the server blade and remove it from the system unit see page 36 Do not clean any interior parts of the server blade yourself leave this job to a service technician Do not use abrasive powder or detergents which dissolve plastic to clean the housing exterior Make sure that no liquid gets inside the device and that the ventilation slits on the ServerBlade remain open Wipe the server blade housing with a dry cloth to clean If it is very dirty you can use a damp cloth that has been dipped in water with a mild detergent and well wrung out BX960 S1 Operating Manual 49 Cleaning the Server Blade 50 Operating Manual BX960 S1 6 Property and data protection The lockable rack door protects the server against unauthorized access To protect the system and data internally against unauthorized access you can activate the security functions of the BIOS Setup 6 1 BIOS Setup security functions The Security menu in the BIOS Setup provides you with various options for protecting your data from unauthorized access By combining these options you can also achieve optimum protection for your system A detailed description
5. CNS 13438 class A VCCI class A AS NZS CISPR 22 class A GB 9254 class A GB 17625 Interference emissions EN 55022 class A Harmonic current EN 61000 3 2 Flicker EN 61000 3 3 Interference immunity EN 55024 EN 300386 CE marking to EU directives Low Voltage Directive 2006 95 EC product safety Electromagnetic compatibility 2004 108 EC Mechanical environmental EN 60721 3 3 class 3M2 conditions 18 Operating Manual BX960 S1 Technical data Certification Product safety approved with the PRIMERGY BX900 S1 system unit Global CB Germany GS CE USA Canada CSAys CSAc Japan VCCI China Taiwan BSMI Mechanical specifications Width 45 mm Depth 508 mm Height 420 mm 2 bays in the system unit Weight Max 12 4 kg depending on the configuration Ambient conditions Environment class 3K2 EN 60721 IEC 721 Part 3 3 Environment class 2K2 EN 60721 IEC 721 Part 3 2 Temperature Operation 3K2 5 2C 35 C Transport 2K2 20 C 60 C Humidity 10 85 non condensing Condensation during operation must be avoided BX960 S1 Operating Manual 19 Technical data 20 Operating Manual BX960 S1 2 Overview Installation steps This chapter contains an overview of the steps necessary to install your Server Blade The cross references take you to the sections containing more detailed information on the relevant installation step
6. Do not unpack the server until it is at its installation location gt Transport the server to the place where you want to set it up gt Unpack all individual parts Keep the original packaging in case you want to transport the server again applies only to EMEA market gt Check the delivery for any damage during transport gt Check whether the items delivered match the details on the delivery note The product name and serial number of the product can be found on the ID card see section ID card on page 44 gt Notify your supplier immediately should you discover that the items delivered do not correspond to the delivery note 4 2 Installing the Server Blade in the system unit CAUTION e Note the safety instructions and the information on handling electrostatically sensitive devices in section Safety instructions on page 23 e Note the population rules for power supply units and fan modules to ensure sufficient cooling of the system You will find more detailed information on this in the operating manual for the BX900 S1 system unit 34 Operating Manual BX960 S1 Installing the Server Blade in the system unit Removing dummy modules Any unused slots on the front of the system unit are fitted with appropriate dummy modules to comply with electromagnetic compatibility EMC regulations and to ensure sufficient cooling of the system components To add a BX960 S1 server blade you must first remove dummy mo
7. 1 In the case of a monitor connected locally via the Y cable see Connecting devices on page 37 BX960 S1 Operating Manual 55 Hard disk drive error messages at system boot Power budget limit value exceeded gt Check whether the power budget limit value set in the management blade has been exceeded You may need to install an additional power supply unit 7 7 Hard disk drive error messages at system boot Various hard disk drive error messages may appear when the system is rebooted These error messages are caused by modifications in the selected RAID configuration RAID controller configuration incorrect gt Check and correct the settings for the drives using the RAID controller configuration program Further information can be found in the operating manual for the RAID controller 56 Operating Manual BX960 S1 Added drive reported as defective 7 8 Added drive reported as defective RAID controller is not configured for this drive The drive was probably installed when the system was switched off gt Reconfigure the RAID controller for the drive using the corresponding utility Information is provided in the documentation for the RAID controller or gt Remove and reinstall the drive while the system is switched ON If the drive continues to be shown as defective then replace it see SSD drive on page 60 7 9 Error message on screen The meaning of the error message is explained in the documen
8. 4 3 Connecting devices All connections that are required to operate the server blade are made via the midplane of the PRIMERGY BX900 S1 system unit When the server blade is installed midplane contacts automatically establish connections to the infrastructure modules on the rear of the system unit Power supply units Management blade s for server administration BX960 S1 Operating Manual 37 Connecting devices Ethernet and or fiber channel connection blades for connection to a LAN or SAN You can find information about the external ports of the BX900 S1 system unit in the relevant operating manual The front of the server blade has a port for a special Y cable which provides 4 USB ports 1 VGA port and 1 serial port Figure 5 Ports on the front 1 VGA port 2 Serial port 3 USB ports 4x 4 Plug connection to the server blade The labeled side of the plug must face left when plugged in 5 Y cable port on the server blade Table 2 External ports on the front i The Y cable is delivered with the system unit 38 Operating Manual BX960 S1 Instructions for connecting disconnecting cables 4 4 Instructions for connecting disconnecting cables CAUTION Be sure to read the documentation for the peripheral devices before connecting them Do not connect or disconnect data cables during a thunderstorm When removing a cable always hold it by the plug Never u
9. Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided You can prevent damage from the optical drive and the CDs DVDs BDs as well as premature wear of the disks by observing the following suggestions Only insert disks in the drive when needed and remove them after use Store the disks in suitable sleeves Protect the disks from exposure to heat and direct sunlight Laser information The optical drive complies with IEC 60825 1 laser class 1 CAUTION The optical drive contains a light emitting diode LED which under certain circumstances produces a laser beam stronger than laser class 1 Looking directly at this beam is dangerous Never remove parts of the optical drive casing 28 Operating Manual BX960 S1 Safety instructions Modules with Electrostatic Sensitive Devices Modules with electrostatic sensitive devices are identified by the following sticker A Figure 1 ESD label When you handle components fitted with ESDs you must always observe the following points Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs You must always discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chas
10. and makes an excellent large application server terminal server for compute intensive applications or DBMS server Security functions in the BIOS Setup protect the data on the server blade from unauthorized changes The server blade occupies 2 bays one upon the other in the BX900 S1 system unit You can find information about assembling starting up and operating the BX900 S1 system unit in the relevant operating manual 1 1 Concept and target groups for this manual This operating manual describes how to install set up and operate your server This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly It contains all the information you need to put your PRIMERGY BX960 S1 into operation To understand the various expansion options you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system BX960 S1 Operating Manual 9 Documentation overview 1 2 Documentation overview PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2 The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server If you no longer have the ServerView Suite DVDs you can obtain the relevant current versions using the order number U15000 C289 the order number for the Japanese market please refer to the configurator of the server http primeserver
11. and modular thus enabling quick and simple maintenance The two redundant hot pluggable management blades of the system unit with independent LAN and COM ports for management enable comprehensive remote administration of the server blade Together they allow remote diagnosis for system analysis remote configuration and remote restart even in the case of operating system failure or hardware errors 16 Operating Manual BX960 S1 Notational conventions 1 4 Notational conventions The following notational conventions are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and terms that are being emphasized describes activities that must be performed in the order shown CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data Li indicates additional information notes and tips BX960 S1 Operating Manual 17 Technical data 1 5 Technical data Electrical data Energy consumption 1 178 W fully equipped Heat dissipation 4 241 kJ h applies to processors up to 105 W Compliance with regulations and standards Product safety and IEC 60950 1 2 EN 60950 1 2 ergonomics UL CSA 60950 1 2 CNS 14336 GB 4943 EN 50371 Electromagnetic compatibility FCC class A
12. are not met BX960 S1 Operating Manual 21 Local installation with or without ServerView Installation Manager Local installation is the least convenient method It is only recommended if the requirements for remote installation and cloning are not met If you want to install an operating system that is not supported by ServerView Installation Manager you can of course install it directly without ServerView Installation Manager For more information about installing the server remotely or locally please refer to the ServerView Suite Installation Manager user guide You can find a description of how to clone server blades in the ServerView Deployment Manager user guide on ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Server Installation and Deployment 22 Operating Manual BX960 S1 3 Important notes This chapter provides safety instructions which you must observe when handling your server 3 1 Safety instructions The following safety instructions are also provided in the manual Safety Notes and Regulations or Z LOQ TFB This device meets the relevant safety regulations for IT equipment If you have any questions about whether you can install the server in the intended environment please contact your sales outlet or our customer service team CAUTION e The actions described in this manual shall be performed by technical specialists A technical specialist is a
13. installation Connect the monitor mouse keyboard and a DVD drive to the port on the server blade control panel with the aid of the special Y cable See Connecting devices on page 37 Make sure that the energy saving functions are disabled in the Power menu of the BIOS Setup during operation and that the DVD drive has been activated as a boot medium 5 3 2 Configuring the onboard SATA controller A SATA controller is integrated on the system board You can configure the onboard SATA controller either before or during installation with the ServerView Installation Manager Using the ServerView Installation Manager is recommended 46 Operating Manual BX960 S1 Configuring the Server Blade The controller has its own configuration utility For further information il refer to the Embedded MegaRAID Software User s Guide on the ServerView Suite DVD 2 under Industry Standard Servers Expansion Cards Storage Adapters LSI RAID SCSI Controllers Descriptions of operating systems not covered in the controller manual are provided in the corresponding readme files on the driver CDs 5 3 3 Configuring the server and installing the operating system with the ServerView Installation Manager Using the ServerView Installation Manager on the ServerView Suite DVD 1 provided you can conveniently configure the server and install the operating system This includes configuring the server specific settings using the ServerView Con
14. is used in a hot environment The customer shall bear the cost of replacing replaceable components which have exceeded their operating life Note that these are only guidelines and do not constitute a guarantee of trouble free operation during the maintenance support period High safety use This product has been designed and manufactured for general uses such as general office use personal use domestic use and normal industrial use It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured BX960 S1 Operating Manual These uses include control of nuclear reactions in nuclear power plants automatic airplane flight control air traffic control traffic control in mass transport systems medical devices for life support and missile guidance control in weapons systems hereafter high safety use Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use Please consult the sales staff of Fujitsu if intending to use this product for high safety use Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning To prevent a momentary voltage drop use of an AC uninterruptible power supply is recommended This notice follows the guidelines of Voltage Dip
15. of the Security menu and how to assign passwords can be found in the BIOS Setup documentation on the ServerView Suite DVD 2 Preventing unauthorized BIOS Setup calls You can activate this protection by entering a setup password in the Security menu You can also suppress the Press F2 for Setup message in this menu This message is then no longer displayed while the server s startup routine is in progress Preventing unauthorized system access You can activate this protection by entering a system password in the Security menu Preventing unauthorized access to the boards with their own BIOS You can activate this protection by selecting the Extended item for Setup Password Lock field in the Security menu Preventing the system from booting from the floppy disk drive You can activate this protection by selecting the item Diskette Lock for the System Load field in the Security menu BX960 S1 Operating Manual 51 BIOS Setup security functions Preventing unauthorized writing to floppy disks To activate this protection select the value Disabled for the Diskette Write field in the Security menu Protecting BIOS from being overwritten To activate this protection select the value Disabled for the Flash Write field in the Security menu Protecting the server from being switched on by an external device To activate this protection select the value Disabled for the Remote Power On field in the Security menu Protecting the s
16. person who is trained to install the server including hardware and software e Repairs to the device that do not relate to CSS failures shall be performed by service personnel Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability e Any failure to observe the guidelines in this manual and any improper repairs could expose the user to risks electric shock energy hazards fire hazards or damage the equipment e Before installing removing internal options to from the server turn off the server all peripheral devices and any other connected devices Also unplug all power cords from the power outlet Failure to do so can cause electric shock BX960 S1 Operating Manual 23 Safety instructions Before starting up CAUTION During installation and before operating the device observe the instructions on environmental conditions for your device see section Technical data on page 18 If the server has been moved from a cold environment condensation may form both inside and on the outside of the machine Wait until the server has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the server if this requirement is not met Only transport the server in the original packaging or in packaging that protects it from impacts and jolts Installation and operation CAUTION The device may only b
17. 66 Operating Manual BX960 S1 SSD drive Figure 15 Installing the mezzanine cards carrier gt Install the mezzanine cards carrier in the server blade housing As you do this the riser cards are inserted in the corresponding system board slots Make sure that the coding on the carrier matches that on the server blade housing see circles BX960 S1 Operating Manual 67 SSD drive 8 1 3 Closing the server blade Figure 16 Closing the server blade gt Place the server blade cover on the housing about 1 2 cm from the frame so that it lies flush on both sides gt Slide the cover forward in the direction of the arrow until it engages gt Install the server blade in the system unit see Installing the Server Blade in the system unit on page 34 68 Operating Manual BX960 S1 Index A acclimatization time 33 Advanced Video Redirection 14 ambient conditions 19 ASR amp R 14 availability 14 AVR 14 B batteries 26 BIOS security functions 51 BIOS update 16 Cc Cables disconnecting 39 cables connecting 39 CE marking 18 30 certification product safety 19 Class A Compliance Statement 30 clean keyboard 49 mouse 49 screen 49 server 49 connect external devices 39 connecting cables 39 consumables 31 correcting faults 53 CSS indicator 43 44 D datachanges 9 data protection 51 data security 14 date incorrect 55 delivery note 34 Disconnecting cables 3
18. 8 30 M management LAN connector 14 meaning of the symbols 17 mezzanine card 12 mezzanine carrier remove 63 monitor display drifts 55 no display 55 N notational conventions 17 0 On Off button 42 onboard SATA controller 46 overload 15 overview installation steps for the server blade 21 P packaging 31 34 PCI SAS controller configuring 48 PCle Gen2 slot 12 PDA 14 15 ports USB 13 power on indicator 42 product name 34 44 property protection 51 R RAID controller is not configured for this drive 57 recycling devices 32 regulations and standards 18 Remote Storage 14 return of devices 32 S Safety instructions 23 safety standards 18 70 Operating Manual BX960 S1 Index saving energy 31 Screen flickering 54 screen error message 57 remains blank 53 shows flickering stripes 54 security functions 9 setup password 51 system password 51 unauthorized access 51 serialnumber 34 44 Server electrical data 18 safety standards 18 transportation 30 server configuration 16 correcting faults 53 data protection 51 dimensions 19 productname 34 property protection 51 serialnumber 34 switches itself off error 53 technical data 18 troubleshooting 53 unpacking 34 ventilation clearance 19 weight 19 server blade close 68 connection panel 41 control panel 41 controls 41 dummy module 35 indicators 41 remove cover 62 removing from system unit 61 server management 15 ServerView InstallationMa
19. 9 disposal devices 32 Drive dead 56 drive defective 57 dummy module install 35 server blade 35 E ECC 14 Electrical data 18 electromagnetic compatibility electrostatic sensitive devices ESD 29 EMC directive 18 environment class 19 environmental protection 31 error drifting display on monitor 55 drive dead 56 drive defective 57 incorrect date 55 incorrect time 55 no display on monitor 55 screen remains blank 53 screen shows flickering stripes 54 server switches itself off 53 system does not boot 55 Error Correcting Code 14 error message on screen 57 expansion card 12 external devices connect 39 18 30 BX960 S1 Operating Manual 69 Index F fault drifting display on monitor 55 drive defective 57 incorrect date 55 incorrect time 55 no display on monitor 55 screen remains blank 53 screen shows flickering stripes 54 system does not boot 55 FCC statement 30 flash EPROM 16 G Global Error indicator 43 l ID button 42 ID card 44 product name 34 44 serial number 34 44 ID indicator 43 indicators CSS 43 44 Global Error 43 ID 43 system error 43 information additional 11 install dummy module 35 installation steps for the server blade overview 21 installation steps overview 21 Installing the operating system 48 integrated Remote Management Controller 14 iRMC S2 14 L labels 32 laser information 28 light emitting diode LED 28 lithium battery 26 Low Voltage Directive 1
20. Immunity of Personal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferred to non residents of Japan without first obtaining authorization in accordance with the above law Harmonic Current Standards This product conforms to harmonic current standard JIS C 61000 3 2 Only for the Japanese market About SATA hard disk drives The SATA version of this server supports hard disk drives with SATA BC SATA storage interfaces Please note that the usage and operation conditions differ depending on the type of hard disk drive used Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive http primeserverfujitsu com primergy harddisk Operating Manual BX960 S1 Only for the Japanese market Although described in this manual some sections do not apply to the Japanese market These options and routines include USB Flash Module UFM CSS Customer Self Service Replacing the lithium battery BX960 S1 Operating Manual Operating Manual BX960 S1 Contents 1 INMPOU
21. UCHON ss 6 254 6S eS Sede Gee eae Pe eeare oe ce 9 1 1 Concept and target groups for this manual 9 1 2 Documentation overview 0252858 82s 10 1 3 Performance features 2 2 0 ee eee ees 11 1 4 Notational conventions 0 08285086 17 1 5 TeECMiiGadl Gala bce eet te dee bee ee eee pe eS s 18 2 Overview Installation steps 2e2088 21 3 Important notes lt 52sec ee ee ee eee ee ee 23 3 1 Safety instructions 2 2 2 0 ee eee ee ee 23 3 2 CEGONKINNY 2fe6 5486 noose ees ct eneeeds 30 3 3 FCC classAdevice 02 0 ee eee eee 30 3 4 Transporting the Server Blade 2204 30 3 5 Notes on installation in the system unit 31 3 6 Environmental protection 2 2 28 8805 31 4 Installing the hardware 2 6 6 ee ee eee eee 33 4 1 Unpacking the server 2 2 2002 eee eee 34 4 2 Installing the Server Blade in the system unit 34 4 3 Connecting devices 2 20 ee eee eee eee 37 4 4 Instructions for connecting disconnecting cables 39 5 Installation and operation 2282850088 41 5 1 Control and display elements naaa aaa 41 BX960 S1 Operating Manual Contents 5 2 5 3 5 3 1 5 3 2 5 3 3 5 3 4 5 4 6 1 7 1 7 2 7 3 7 4 7 5 7 6 7 7 7 8 7 9 Switching the Server Blade on andoff 45 Configuring the Server Blade 2 22205 46 Preparing for local installation 46 Configuring th
22. are marked with a symbol a crossed out garbage can In addition the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead 26 Operating Manual BX960 S1 Safety instructions Working with CDs DVDs BDs and optical drives When working with devices with optical drives these instructions must be followed CAUTION Only use CDs DVDs BDs that are in perfect condition in order to prevent data loss equipment damage and injury Check each CD DVD BD for damage cracks breakages etc before inserting it in the drive Note that any additional labels applied may change the mechanical properties of a CD DVD BD and cause imbalance Damaged and imbalanced CDs DVDs BDs can break at high drive speeds data loss Under certain circumstances sharp CD DVD BD fragments can pierce the cover of the optical drive equipment damage and can fly out of the device danger of injury particularly to uncovered body parts such as the face or neck High humidity and airborne dust levels are to be avoided Electric shocks and or server failures may be caused by liquids such as water or metallic items such as paper clips entering a drive Shocks and vibrations are also to be avoided Do not insert any objects other than the specified CDs DVDs BDs Do not pull on press hard or otherwise handle the CD DVD BD tray roughly Do not disassemble t
23. d off it can be switched on again by pressing the On Off button When the system is operating pressing the On Off button will switch off the system CAUTION Risk of loss of data The On Off button does not disconnect the server from the mains voltage To disconnect from the mains completely remove the power plug s ID button Lights up blue on itself when the ID button is pressed LEDs on the control panel Power indicator three color Does not light up if no line voltage is present Lights orange when the server is switched off but line voltage is present Lights yellow to indicate a power supply error Lights up green when the server is switched on Flashes green when the server has been switched on and is in standby mode 42 Operating Manual BX960 S1 Control and display elements css Global Error indicator orange Lights up orange if a prefailure event has been detected that requires precautionary service intervention Flashes orange if an error was detected that requires service intervention Does not light up if there is no critical event If the event is still acute after a power failure the indicator is activated after the restart The indicator lights up in failure mode until the faults are cleared You can find more details on the indicated errors in the System Event Log SEL inthe Management Blade Web interface on the ServerView Local Service Panel on the S
24. d or additional Ethernet connections to be implemented The following mezzanine cards are available for the server blade 1 Gbit s Ethernet mezzanine card with 4 ports 2x Intel 82575 controllers each with two 1 Gbit s channels 12 Operating Manual BX960 S1 Performance features 10 Gbit s Ethernet mezzanine card with 2 ports Intel 82599EB controller 8 Gbit s fiber channel card with 2 ports compatible with Emulex LPe12002 If a server blade is configured with up to four mezzanine cards this does not exclude other configurations for any of the other server blades in a BX900 S1 system unit If you want to install mezzanine cards in server blades the system unit must be fitted with the corresponding Fibre Channel Infiniband and or Ethernet connection blades You can find detailed information about the equipping rules for connection blades in the operating manual for the BX900 S1 system unit Mezzanine cards may only be installed and removed by authorized qualified personnel The procedure is described in the options guide SSD drives Two SSD drives Solid State Disk drives can be installed in the server blade The SSD drives are mounted at the place of mezzanine card 1 using a special mezzanine card carrier The connection to the onboard controller is established through a riser card The installation procedure is described in the options guide A UFM USB flash module can also be configured SATA RAID
25. dules from the relevant slots Figure 2 Removing the server blade dummy module gt Pull up the handle of the dummy module arrow to unlock it gt Pull the dummy module out of the slot CAUTION Keep the dummy module for future use If you remove a server blade and do not replace it with a new one you must install a dummy module to comply with the regulations regarding electromagnetic compatibility and to ensure sufficient cooling of the system components BX960 S1 Operating Manual 35 Installing the Server Blade in the system unit Installing the dummy module To install the dummy module follow the same procedure as for removing it except in reverse order Installing the Server Blade CAUTION Follow the safety instructions and information in section Modules with Electrostatic Sensitive Devices on page 29 Figure 3 Installing the Server Blade gt Open the release lever 1 gt Push the server blade as far as possible into the slot 36 Operating Manual BX960 S1 Connecting devices Figure 4 Locking the Server Blade gt Pull the release lever up until it engages Removal is carried out in reverse order CAUTION If you remove a BX960 S1 server blade and do not replace it with a new one you must install dummy modules to comply with the regulations regarding electromagnetic compatibility and to ensure sufficient cooling of the system components
26. e onboard SATA controller 46 Configuring the server and installing the operating system with the ServerView Installation Manager 47 Configuring the server and installing the operating system without ServerView Installation Manager 48 Cleaning the Server Blade 22002 200 49 Property and data protection 0022005 51 BIOS Setup security functions 2 4 51 Troubleshooting and tips 028008 53 Server switches itself off 22 05228005 53 Screen remains blank 2 20 06 2 ee eee eee 53 Flickering stripes on monitor screen 54 No screen display or display drifts 55 Incorrect date and time 0 0 02828 e eee 55 System willnotboot 0 0008 eee eee 55 Hard disk drive error messages at system boot 56 Added drive reported as defective 5 57 Error message onscreen 2 022 8 ee eee 57 Replacing CSS components 2 585 59 SSP CVG coe d4 a eee ee to o4 SSS KOS Oey 60 Opening the serverblade 22 61 Replacing the SSD drive 2 2 63 Closing the server blade 22200 68 ieee kOe ee ee ek de oe ae ee a 69 Operating Manual BX960 S1 1 Introduction The PRIMERGY BX960 S1 server blade is an Intel based quad socket server blade It is ideal for use in data centers belonging to enterprises or Internet service providers
27. e operated in a maximum ambient temperature of 35 C If the device is integrated in an installation that receives power from an industrial public power supply network with the IEC309 connector the public power supply protection must comply with the requirements for non industrial public power supply networks for the type A connector The On Off button or the main power switch if there is one does not disconnect the device from the mains voltage To completely disconnect it you must remove all the power plugs from the power outlets Data cables must be adequately shielded to avoid interference Do not connect or disconnect any data transmission cables during a thunderstorm lightning hazard Make sure that no objects e g bracelets or paper clips fall into or liquids spill into the device risk of electric shock or short circuit 24 Operating Manual BX960 S1 Safety instructions CAUTION In emergencies e g damaged casing control elements or power cable penetration of liquids or foreign bodies switch off the device immediately unplug it from the grounded power outlets and contact your customer service center Proper operation of the device in accordance with IEC 60950 1 EN 60950 1 is only ensured if the casing is fully assembled and the rear covers for the installation bays are in place electric shock cooling fire protection interference suppression Install only system extensions that sati
28. erver from being switched off by a program To activate this protection select the value Disabled for the Soft Power Off field in the Security menu 52 Operating Manual BX960 S1 7 Troubleshooting and tips CAUTION Follow the safety instructions in the Safety notes and regulations manual or 4 E 2 and in chapter Important notes on page 23 If a fault occurs attempt to resolve it using the measures described inthis chapter inthe documentation for the connected devices inthe help systems of the software used If you fail to correct the problem proceed as follows gt Make alist of the steps performed and the circumstances that led to the fault Also make a list of any error messages that were displayed gt Switch off the server gt Contact our customer service team 7 1 Server switches itself off Server Management has detected an error gt Check the Event Log of the management blade or if ServerView Operations Manager is installed its error list or the ErrorLog file and attempt to eliminate the error 7 2 Screen remains blank Monitor is switched off gt Switch on your monitor 1 In the case of a monitor connected locally via the Y cable see Connecting devices on page 37 BX960 S1 Operating Manual 53 Flickering stripes on monitor screen Screen has gone blank gt Press any key on the keyboard or gt Deactivate screen saver Enter the appropr
29. erverView Local Service Display in the ServerView Operations Manager or via the iIRMC S2 s Web interface CSS indicator yellow Lights up yellow if a prefailure event was detected fora CSS component that you can fix yourself for reasons of precaution with the CSS concept Flashes yellow if an error was detected that you can fix yourself with the CSS concept Does not light up when the system is OK If the event is still acute after a power failure the indicator is activated after the restart The indicator lights up in failure mode until the faults are cleared For more information on the CSS concept see Customer Self Service CSS on page 11 ID indicator blue Lights up blue when the system has been selected by pressing the ID button To deactivate press the button again The ID indicator can also be activated via the Management Blade Web interface and via the ServerView Operations Manager and the iIRMC S2 Web interface and its status reported to the ServerView Operations Manager and the iRMC S2 BX960 S1 Operating Manual 43 Control and display elements Status indicators LEDs green Lights up to indicate a network connection Flashes to indicate an active network connection Does not light up if there is no network connection ID card You can pull out the ID card see figure 6 on page 41 above as far as it will go and push it back in again The ID card contains vario
30. etails regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 525 1410 Fax 49 5251 525 32 1410 32 Operating Manual BX960 S1 4 Installing the hardware CAUTION e Follow the safety instructions in the chapter Important notes on page 23 e Do not expose the server to extreme environmental conditions see Ambient conditions on page 19 Protect the server from dust humidity and heat e Make sure that the server is acclimatized for the time indicated in this table before putting it into operation Temperature difference C Minimum acclimatization time hours 5 3 10 5 15 7 20 8 25 9 30 10 Table 1 Acclimatization time In the table Acclimatization time the temperature difference refers to the difference between the operating environment temperature and the temperature to which the server was exposed previously outside transport or storage temperature BX960 S1 Operating Manual 33 Unpacking the server 4 1 Unpacking the server CAUTION Follow the safety instructions in Safety instructions on page 23 The server must always be lifted or carried by at least two people For the Japanese market please refer to R ENDER
31. f the setting in the BIOS Setup You can also switch the server blade on and off via the system unit i control panel or via the Web interface of the ServerView Management Blade Detailed information is provided in the manual PRIMERGY BX900 Blade Server Systems ServerView Management Blade S1 User Interface Description BX960 S1 Operating Manual 45 Configuring the Server Blade 5 3 Configuring the Server Blade This section contains information about configuring the server blade and installing the operating system The operating system can be installed in various ways Local installation with or without the ServerView Installation Manager You can find information on local installation in the following sections Remote installation using console redirection via the user interface of the ServerView Management Blade You can find information on console redirection in the manual PRIMERGY BX900 Blade Server Systems ServerView Management Blade S1 User Interface Description Apart from this the operating system installation is carried out in the same way as a local installation Importing the clone images from an image repository to the desired server blades For more information about this procedure see the ServerView Deployment Manager 5 0 manual on PRIMERGY ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Server Installation and Deployment 5 3 1 Preparing for local
32. figuration Manager and configuring the RAID controller using the ServerView RAID Manager Advantages of the ServerView Installation Manager Wizard assisted configuration of your server hardware and disk arrays Wizard assisted installation of all leading server operating systems Wizard assisted creation of configuration files for unattended installation of several PRIMERGY servers with identical hardware configurations Installation of drivers and additional software The software that can be installed depends on your server s hardware configuration This configuration is detected automatically manual are provided in the corresponding readme files on the driver CDs To find out how to operate the ServerView Installation Manager and for further information refer to the associated manual il Descriptions of operating systems not covered in the RAID controller If you are using the ServerView Installation Manager you can skip the following section on how to configure the server and install the operating system Continue from section Cleaning the Server Blade on page 49 BX960 S1 Operating Manual 47 Configuring the Server Blade 5 3 4 Configuring the server and installing the operating system without ServerView Installation Manager onboard SATA controller configuring Configure the controller as described in section Configuring the onboard SATA controller on page 46 Installing the operating system
33. fujitsu com primergy system html The PDF files of the manuals can also be downloaded free of charge from the Internet The overview page showing the online documentation available on the Internet can be found using the URL for EMEA market http manuals ts fujitsu com The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option For the Japanese market please use the URL http primeserverfujitsu com primergy manual html More information on your PRIMERGY BX960 S1 server blade can be found in the following documents Quick Start Software Quick Installation Guide DVD booklet only included as a printed copy with the ServerView Suite Safety Notes and Regulations manual Z CEE for the Japanese market Warranty manual RE for the Japanese market PRIMERGY ServerView Suite Local Service Concept LSC manual Returning used devices manual and Service Desk leaflet 7R k amp U ERZR for the Japanese market System Board D2873 for BX960 S1 Technical Manual D2873 BIOS Setup Utility for PRIMERGY BX960 S1 server blade reference manual PRIMERGY BX960 S1 Server Blade Operating Manual PRIMERGY BX960 S1 Server Blade Options Guide Operating Manual BX960 S1 Performance features Further sources of information PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2 Manual for the monitor Documentation for the boards and drives
34. he optical drive Before use clean the optical disk tray using a soft dry cloth As a precaution remove disks from the optical drive when the drive is not to be used for a long time Keep the optical disk tray closed to prevent foreign matter such as dust from entering the optical drive Hold CDs DVDs BDs by their edges to avoid contact with the disk surface BX960 S1 Operating Manual 27 Safety instructions e Do not contaminate the CD DVD BD surface with fingerprints oil dust etc If dirty clean with a soft dry cloth wiping from the center to the edge Do not use benzene thinners water record sprays antistatic agents or silicone impregnated cloth e Be careful not to damage the CD DVD BD surface e Keep the CDs DVDs BDs away from heat sources e Do not bend or place heavy objects on CDs DVDs BDs e Do not write with ballpoint pen or pencil on the label printed side e Donotattach stickers or similar to the label side Doing so may cause rotational eccentricity and abnormal vibrations e When aCD DVD BD is moved from a cold place to a warm place moisture condensation on the CD DVD BD surface can cause data read errors In this case wipe the CD DVD BD with a soft dry cloth then let it air dry Do not dry the CD DVD BD using devices such as a hair dryer e To avoid dust damage and deformation keep the CD DVD BD in its case whenever it is not in use e Do not store CDs DVDs BDs at high temperatures
35. iate password Brightness control is set to dark gt Set the brightness control on the monitor to light For detailed information refer to the operating manual supplied with your monitor Power cable or monitor cable not connected gt Switch off the monitor and the server gt Check whether the power cable is properly connected to the monitor and to the grounded socket gt Check whether the monitor cable is properly connected to the server and monitor if it is plugged in with a connector If a separate graphics card is installed in the server then the monitor cable must be connected to the graphics card gt Switch on the monitor and the server 7 3 Flickering stripes on monitor screen CAUTION Switch off the server immediately Risk of damaging the server Monitor does not support the set horizontal frequency gt Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor gt Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor and follow the procedure accordingly 1 In the case of a monitor connected locally via the Y cable see Connecting devices on page 37 54 Operating Manual BX960 S1 No screen display or display drifts 7 4 N
36. nager 16 47 ServerView Operations Manager 15 supported functions 15 service LAN connector 14 setup password 51 slot expansion card 12 Solid State Disk 60 SSD module 60 install 65 switch off time defining 45 switch on time defining 45 switching off system 45 switching on system 45 system switching off 45 switching on 45 system board features 12 system does not boot 55 system information 44 system password 51 T target group 9 Technical data 18 technical data 18 ambient conditions 19 time incorrect 55 tips 53 TPM 12 transport damage 34 troubleshooting 53 troubleshooting server 53 Trusted Platform Module 12 U UFM 13 unauthorized access 51 unpacking server 34 USB port 13 vV ventilation clearance 19 BX960 S1 Operating Manual 71 Index weight 19 72 Operating Manual BX960 S1
37. ng the SSD drive This section describes how to replace the SSD drive in bay SSDO The SSD drive in bay SSD1 is replaced in the same way Removing an SSD drive Figure 10 Removing the mezzanine cards carrier gt Remove the mezzanine cards carrier from the server blade housing by lifting it up keeping it as horizontal as possible BX960 S1 Operating Manual 63 SSD drive Figure 11 Removing the SSD drive mounting frame gt Press the guide element 1 of the SSD drive inward to disengage the locking hooks 2 and thus unlock the drive gt Keep the guide element pressed and slide the SSD drive out of the mounting frame 3 Figure 12 Removing the guide element of the SSD drive gt Remove the guide element of the SSD drive and keep it for installing the replacement 64 Operating Manual BX960 S1 SSD drive Installing an SSD drive Figure 13 Fitting the SSD drive into the guide element gt Fit the SSD drive into the green plastic guide element The 4 clips of the guide elements see circles must engage in the holes of the SSD drive BX960 S1 Operating Manual 65 SSD drive Figure 14 Inserting the SSD drive in the mounting frame gt Slide the SSD drive with the guide element into the mounting frame Make sure that the clips of the guide element see circles engage in the openings of the mounting frame 1
38. nplug a cable by pulling at the cable itself Connect and disconnect the cables in the order described below Connecting cables gt gt gt gt gt Turn off all power and equipment switches Disconnect all power plugs from the grounded shockproof sockets Connect all cables to the server and peripherals Plug all data communication cables into the utility sockets Plug all power cables into the grounded shockproof sockets Disconnecting cables gt gt gt gt Turn off all power and equipment switches Disconnect all power plugs from the grounded shockproof sockets Unplug all data communication cables from the utility sockets Disconnect the relevant cables from the server and all the peripherals BX960 S1 Operating Manual 39 Instructions for connecting disconnecting cables 40 Operating Manual BX960 S1 5 Installation and operation CAUTION Follow the safety instructions in the chapter Important notes on page 23 5 1 Control and display elements DU UL a a Figure 6 Control and display elements ID card CSS indicator Mezzanine 2 and 4 indicator Global Error indicator Mezzanine 1 and 3 indicator ID button with ID indicator AJOJN INI IOJ NIC indicator On Off button with power on indicator BX960 S1 Operating Manual 41 Control and display elements Control elements On Off button When the system is switche
39. o screen display or display drifts The wrong horizontal frequency or resolution has been selected for the monitor or for the application program gt Find out which horizontal frequency your monitor screen supports You will find the horizontal frequency also known as line frequency or horizontal deflection frequency in the documentation for your monitor gt Refer to the documentation for your operating system or the software for the screen controller for details of how to set the correct horizontal frequency for your monitor and follow the procedure accordingly 7 5 Incorrect date and time gt Set the date and time in the operating system or in the BIOS Setup under the Main menu using System Date and System Time respectively Note that the operating system may affect the system time For example the operating system time may deviate from the system time under Linux and would overwrite the system time in the default setting on shutdown If the date and time are still wrong after the server has been switched off and back on again replace the lithium battery for a description refer to the Technical Manual for the D2873 system board or contact our customer service team 7 6 System will not boot The system will not boot after installing a new hard disk drive SAS configuration incorrect gt Check the settings for the hard disk drives SAS Device Configuration and the additional settings in the SAS configuration menu
40. odules on top of each other 1 SSD backplane SSD module SSD Solid State Disk 3 Plastic holder for the SSD module CAUTION e SSD drive may only be removed by a service technician e The SSD modules must all be clearly marked so that they can be put back in their original places if they are removed If this is not done existing data can be lost e Information about RAID configurations or RAID levels is available in the RAID controller documentation 60 Operating Manual BX960 S1 SSD drive 8 1 1 Opening the server blade gt Exit all applications and shut down the server blade correctly If your operating system has not switched off the server press the on off button on the server blade control panel Removing the server blade from the system unit Figure 8 Removing the server blade gt Push the locking lever 1 up slightly to unlock the release lever 2 gt Swivel the release lever down until it is horizontal gt Pull the server blade out of the system unit BX960 S1 Operating Manual 61 SSD drive Removing the cover Figure 9 Removing the cover gt Press the touch points 1 of the cover to disengage it and slide back the cover as far as it will go in the direction of the arrow 2 gt Take off the cover plate The server blade components are now freely accessible 62 Operating Manual BX960 S1 SSD drive 8 1 2 Replaci
41. ould only be transported in its original packaging Information on handling consumables Please dispose of printer consumables and batteries in accordance with the applicable national regulations In accordance with EU directives batteries must not be disposed of with unsorted domestic waste They can be returned free of charge to the manufacturer dealer or an authorized agent for recycling or disposal BX960 S1 Operating Manual 31 Environmental protection All batteries containing pollutants are marked with a symbol a crossed out garbage can They are also marked with the chemical symbol for the heavy metal that causes them to be categorized as containing pollutants Cd Cadmium Hg Mercury Pb Lead Labels on plastic casing parts Please avoid sticking your own labels on plastic parts wherever possible since this makes it difficult to recycle them Returns recycling and disposal Please handle returns recycling and disposal in accordance with local regulations The device must not be disposed of with domestic waste This device is labeled in compliance with European directive 2002 96 EC on waste electrical and electronic equipment WEEE This directive sets the framework for returning and recycling used HE equipment and is valid across the EU When returning your used device please use the return and collection systems available to you Further information can be found at http ts fujitsu com recycling D
42. quired to transport the device in its original packaging Do not unpack the server blade until it is at its installation location 30 Operating Manual BX960 S1 Notes on installation in the system unit 3 5 Notes on installation in the system unit CAUTION Beware of the energy hazard at the midplane contacts of the system unit A short circuit on these contacts may damage the system 3 6 Environmental protection Environmentally friendly product design and development This product has been designed in accordance with the Fujitsu standard for environmentally friendly product design and development This means that key factors such as durability selection and labeling of materials emissions packaging ease of dismantling and recycling have been taken into account This saves resources and thus reduces the harm done to the environment Further information can be found at http ts fujitsu com products standard_servers index html for the EMEA market http primeserver fujitsu com primergy concept for the Japanese market Energy saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting the system If possible the equipment sh
43. rks of Microsoft Corporation in the USA and other countries Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries Before reading this manual For your safety This manual contains important information for safely and correctly using this product Carefully read the manual before using this product Pay particular attention to the accompanying manual Safety Notes and Regulations and ensure these safety notes are understood before using the product Keep this manual and the manual Safety Notes and Regulations in a safe place for easy reference while using this product Radio interference This product is a Class A ITE Information Technology Equipment In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures VCCI A Aluminum electrolytic capacitors The aluminum electrolytic capacitors used in the product s printed circuit board assemblies and in the mouse and keyboard are limited life components Use of these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product
44. s way the iRMC S2 enables complete control of PRIMERGY servers regardless of system status and thus particularly the control of PRIMERGY servers that are in the out of band system status Major functions supported by the iRMC S2 include the following e Browser access via iRMC S2 s own Web server e Secure communication SSH SSL e Power Management for the managed server depending on its system status e Power Consumption Management e Connecting virtual drives as remote storage e Text based and graphic console bypass Advanced Video Redirection e Command Line Interface CLI e Simple interactive or script based iRMC S2 configuration e Customer Self Service CSS e iRMC S2 s own user management e Multi computer global iRMC S2 user administration using an LDAP Directory Service 14 Operating Manual BX960 S1 Performance features e Automatic network configuration via DNS DHCP e Power supply of the iIRMC S2 via the system standby supply e Full coverage alarm management e System Event Log SEL reading and processing More information about the iRMC S2 can be found in the IRMC S2 integrated Remote Management Controller user s guide on the ServerView Suite DVD 2 under Industry Standard Servers Software ServerView Suite Out Of Band Management Server management Server management is implemented using the ServerView Operations Manager supplied and the PDA Prefailure Detection and Analysis technolog
45. sfy the requirements and rules governing safety electromagnetic compatibility and telecommunications terminal equipment If you install other extensions you may damage the system or violate these safety regulations You can find out which system extensions are suitable from the customer service center or your sales outlet The components marked with a warning label e g lightning symbol may only be opened removed or exchanged by authorized qualified personnel Exception CCS components can be replaced If you cause a defect on the device by installing or exchanging system extensions the warranty will be invalidated Only set the resolutions and refresh rates specified in the operating manual for your monitor Otherwise you may damage the monitor If you are in any doubt contact your sales outlet or customer service center BX960 S1 Operating Manual 25 Safety instructions Batteries CAUTION Incorrect replacement of batteries may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer see the technical manual for the system board Do not throw batteries into the trash can Batteries must be disposed of in accordance with local regulations concerning special waste Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board All batteries containing pollutants
46. sis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or conduction paths on an ESD Place all the components on a pad which is free of electrostatic charge il For a detailed description of how to handle ESD components see the relevant European or international standards EN 61340 5 1 ANSI ESD 20 20 BX960 S1 Operating Manual 29 CE conformity Other important information e During cleaning observe the instructions in section Cleaning the Server Blade on page 49 e Keep this operating manual and the other documentation such as the technical manual documentation DVD close to the device All documentation must be included if the equipment is passed on to a third party 3 2 CE conformity 2004 108 EC regarding Electromagnetic Compatibility and 2006 95 EC Low Voltage Directive This is indicated by the CE marking CE Communaut Europ enne C lt The system complies with the requirements of the EC directives 3 3 FCC class A device Warning This is class A product which may cause radio interference in a domestic environment If this is the case the user may be required to take adequate measures 3 4 Transporting the Server Blade CAUTION Only transport the server blade in its original packaging or in suitable packaging which protects it from knocks and jolts For the Japanese market it is not re
47. support RAID levels 0 and 1 are supported for operation of the SSD drives For more information on configuring the controller see section onboard SATA controller configuring on page 48 Graphics controller The server blade has an onboard graphics controller integrated in the iIRMC S2 controller A monitor can be connected via the Y cable on the front of the server blade External ports The server blade has a port for a special Y cable on the front with 4 USB ports one serial port and one VGA port BX960 S1 Operating Manual 13 Performance features High level of availability and data security When memory data is accessed 1 bit errors are identified in the main memory and automatically corrected with the error correcting code ECC method ASR amp R Automatic Server Reconfiguration and Restart restarts the system in the event of an error and automatically hides the defective system components The PDA Prefailure Detection and Analyzing technology from Fujitsu Technology Solutions analyzes and monitors all components that are critical for system reliability iRMC S2 with integrated management LAN connector The features of the IRMC S2 Advanced Video Redirection and Remote Storage are available as an option The iRMC S2 integrated Remote Management Controller is a BMC with integrated management LAN connector and expanded functionality that was previously only available with additional plug in cards In thi
48. tation for the relevant components and programs on the ServerView Suite DVD 2 BX960 S1 Operating Manual 57 Error message on screen 58 Operating Manual BX960 S1 8 Replacing CSS components This chapter describes how to handle CSS components and how to identify defective CSS components and replace them yourself Further information on the CSS concept is provided in the Customer Self Service CSS manual on the ServerView Suite DVD 2 Upgrades conversions or replacement of non CSS components are described in the Options Guide or in the Service Supplement and may only be carried out by authorized qualified personnel CAUTION Follow the safety instructions in the chapter Important notes on page 23 In the PRIMERGY BX960 S1 server the following components are considered to be CSS components Non hot plug components SSD drives Memory modules These components can be changed by you in the event of an error Enhancements and upgrades may only be carried out by authorized qualified personnel How to replace memory modules is described in the Options Guide BX960 S1 Operating Manual 59 SSD drive 8 1 SSD drive One or two 2 5 inch SSD drives can be installed The SSD drives are installed in a special mezzanine carrier instead of mezzanine card 1 Figure below shows a mezzanine carrier that is fitted with one SSD drive Figure 7 Mezzanine carrier with space for two SSD m
49. tions Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question This feature is not available for the Japanese market System board The features of the system board are described in the technical manual for the system board D2873 for the hardware and in the BIOS Setup chapter of this manual for the firmware Trusted Platform Module TPM A Trusted Platform Module TPM for safer storage of keys can be implemented as an option This module enables programs from third party manufacturers to store key information e g drive encryption using Windows Bitlocker Drive Encryption The TPM is activated via the BIOS system for more information refer to the D2873 BIOS Setup Utility for BX960 S1 manual CAUTION When using the TPM note the program descriptions provided by the third party manufacturers You must also create a backup of the TPM content To do this follow the third party manufacturer s instructions Without this backup if the TPM or the system board is faulty you will not be able to access your data Ifa failure occurs please inform your service about the TPM activation before it takes any action and be prepared to provide them with your backup copies of the TPM content Slots for expansion cards The server blade supports four optional mezzanine cards This enables Fibre Channel connections Infiniband connections an
50. us system information such as product name serial number and order number in the Japanese market only the product name and the serial number 44 Operating Manual BX960 S1 Switching the Server Blade on and off 5 2 Switching the Server Blade on and off CAUTION If you switch the server blade on and flickering stripes appear on the connected monitor switch the server blade off again immediately see chapter Troubleshooting and tips on page 53 The On Off button does not disconnect the device from the mains To fully disconnect the device from the mains you must remove the server blade from the system unit or switch off the system unit and unplug the power plug s Using the control panel to switch the Server Blade on and off The system unit is switched on and the power on indicator item 8 in figure 6 on page 41 is flashing green The server blade can be switched on and off as follows To switch the server blade on press the On Off button on the server blade item 8 in figure 6 on page 41 To switch the server blade off hold down the On Off button on the server blade item 8 in figure 6 on page 41 for 4 seconds Defined switch on off time The server blade is switched on and off at the times defined in the ServerView Operation Manager Other On Off options After power failure Once a server blade has been switched on it will switch itself on again automatically after a power failure irrespective o
51. y from Fujitsu PDA reports the threat of a system error or overload at an early stage allowing preventive measures to be taken The ServerView Operations Manager enables the management of all PRIMERGY servers in the network via a central console The ServerView Operations Manager supports the following functions e Round the clock monitoring regardless of server status e High performance graphical console bypass AVR protected by HTTPS SSL 128 bit e Remote storage via USB e Remote power on e Temperature monitoring of the CPU and the surrounding area e Detailed status and error reports for processors and main memory e Watchdog timer for Automatic Server Reconfiguration and Restart ASR amp R in the event that memory modules or processors fail e Power monitoring e End of life monitoring of fans with prompt notification before failure e Watchdog timer for monitoring the operating system with ASR amp R Further information on the ServerView Operations Manager is provided in the associated documentation BX960 S1 Operating Manual 15 Performance features ServerView Installation Manager You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided User guided menus are available for installing the server operating system for further details see section Configuring the Server Blade on page 46 Service and support PRIMERGY servers are service friendly

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanweisung Istruzioni per l`uso  Samsung BN68-02879E-X0 User's Manual  3831BL manual.cdr  LevelOne Bluetooth v1.2 USB Adapter Class 1  LS7260 LS7262 - Anaheim Automation  Mode d`emploi  MRY3004パンフレット  Mimaki Plotter Assistant 取扱説明書  Samsung Galaxy Ace 2 Εγχειρίδιο χρήσης  American Standard Colony Round Front 14" Rough-In Toilet 4314.016 User's Manual  