Home
FujiFilm FinePix S700 Digital Camera User Manual
Contents
1. 20 Amps Rated Frequency inicial 60 Hz 3600 RPM s snn in enin an Single Phase Maximum wattage and current are subject to and limited by such factors as fuel Btu content ambient temperature altitude engine condition etc Maximum power decreases about 3 596 for each 1 000 feet above sea level and will also decrease about 1 for each 6 C 10 F above 16 C 60 F ambient temperature 3 2 2 ENGINE SPECIFICATIONS Rated Horsepower 3600 14 5 Displacement Spark Plug Type Spark Plug Gap 0 030 inch or 0 76 mm Gasoline Capacity 8 U S gallons Oil Type See Chart in Adding Engine Oil Section Dil ss sers w Filter Change 1 5 Qts w o Filter Change 1 2 Qts Run Time Fuel Consumption 1 2 Load 10 Hours 80 gallons per hour Class 1 Emission Certified MAINTENANCE 20 Section 3 Maintenance Portable Generator System 3 3 GENERAL RECOMMENDATIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain the generator as instructed in this manual Some adjustments will need to be made periodically to properly maintain the generator All adjustments in the Maintenance section of this manual should be ma
2. 200 500 OS AO 20 era ce o 1000 a 1650 Ventilador de sistema de calefacci n 3 5 HP 875 Suministre 3 veces los vatios indicados para arrancar estos aparatos 2 7 ANTES DE ARRANCAR EL GENERADOR Antes de utilizar el generador debe a adir aceite y gasolina al motor como sigue 2 7 1 AGREGAR ACEITE DE MOTOR Todos los aceites de motor deben cumplir con las normas del Instituto Americano del Petr leo API Clase de Servicio SJ SL o mejor No utilice aditivos especiales Elija el grado de viscosidad del aceite de acuerdo con la temperatura de funcionamiento que anticipe refi rase a la tabla Sobre 40 F 4 C utilice SAE 30 Por debajo de 40 F 4 C y hasta 10 F 12 C utilice 10W 30 Por debajo de 10 F 12 C utilice sint tico 5W 30 Rango de temperatura del uso esperado PRECAUCI N 4 Cualquier intento de arrancar el motor antes de que se le haya dado el servicio adecuado con el aceite recomendado puede ocasionar una falla del motor Coloque el generador en una superficie nivelada Limpie el rea alrededor de la toma de aceite y retire la tapa Llene lentamente el motor con aceite hasta que alcance los hilos de la abertura de llenado de aceite ver figura 10 Deje de llenar ocasionalmente para revisar el nivel de aceite Coloque la tapa del conducto para aceite y apri tela de forma segura
3. Lal C mo dos MPA isisisi oiya 1 1 1 Caja de accesorios ote 12 EnsamblajO a coin nia 1 2 1 Ensamblaje del kit de accesorios 1 22 Conexi n del arranque Arranque el ctrico NICAMENTE ion Secci n 2 s ssssssessesrrerssrrnsn 2 1 Conozca el generador 22 Contador horario a s s s s once eitis 23 Juegos de cables y enchufes de conexi n 2 3 1 Tomacorriente d plex de 120 VAC 20 Amp 2 8 2 Tomacorriente de 120 240 VAC 30 Amp 24 C mo utilizar el 2 4 1 Conexion a tierra del generador 2 4 2 Conexi n de las cargas el ctricas 25 sobrecargue el 2 6 Guia de referencia del 2 7 de arrancar el 2 7 1 Agregar aceite de 2 2 Agregar gastia sse 2 8 C mo arrancar los motores por tracci n 2 9 C mo arrancar los motores de arranque el ctrico 2 10 C mo parar el motor 2 11 Sistema de apagado por bajo nivel de aceite 2 11 1 Sensor de bajo nivel de aceite 2 12 C mo recargar una bater a
4. esesess 12 3 8 5 Changing the Oil a 12 3 3 6 Replacing the Spark Plug 12 3 8 7 Replacing the 12 3 4 Service Air Gleaner 13 3 5 Clean Spark Arrestor Screen 13 3 6 Adjusting Valve 13 3 7 LONG Term Storage 14 3 8 Other Storage Tips 14 Section 4 Troubleshooting 15 4 1 Troubleshooting Guide 15 Section 5 16 Section 6 18 Manual del 0 1818110 19 Manuel d entretien 37 INTRODUCTION Thank you for purchasing this model by Generac Power Systems Inc This model is a compact high performance air cooled engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in place of utility due to a power outage READ THIS MANUAL THOROUGHLY If any portion of this manual is not understood contact the nearest Authorized Dealer for starting operating and servicing procedures The operator is responsible for proper and safe use of the equipment We strongly recommend that the operator read this
5. 35 Secci n 5 Garant a ic 36 INTRODUCCI N Gracias por comprar este modelo de Generac Power Systems Inc Este modelo es un generador impulsado por motor refrigerado por aire compacto y de alto rendimiento dise ado para proporcionar energ a el ctrica para operar cargas el ctricas donde no haya servicio p blico de electricidad o en reemplazo de la red el ctrica en caso de apagones LEA ESTE MANUAL COMPLETAMENTE Si alguna parte de este manual no se entiende bien p ngase en contacto con el concesionario autorizado m s cercano para conocer los procedimientos de arranque operaci n y servicio El operador es responsable del uso apropiado y seguro de este equipo Recomendamos encarecidamente que el operador lea este manual y entienda completamente todas las instrucciones antes de usar este equipo Asimismo recomendamos con igual firmeza el instruir a otros usuarios para arrancar y operar apropiadamente la unidad Esto los prepara si necesitan operar el equipo en alguna emergencia El generador puede operar en forma segura eficiente y confiable s lo si se le ubica se le opera y mantiene en forma apropiada Antes de operar 0 dar servicio al generador Familiaricese y adhi rase estrictamente a todos los c digos y regulaciones locales estatales y nacionales e Estudie todas las advertencias de seguridad en este manual y en el producto con mucho cuidado Familiaricese con este manual y la unidad an
6. 3800 Climatiseur 40 000 Btu 6000 Chargeur de batterie 20 500 Ponceuse bande 3 1000 Scie eser IRI E ERR X baa La 1200 Scie circulaire 6 5 po 800 a 1 000 S che linge lectrique 5750 S che linge gaz 700 Machine laver 1150 Pri P non kee head wee ae ae k 1750 Compresseur 1 HP 2000 Compresseur 0 75 HP 1800 Compresseur 0 5 1400 I EBERT EET 700 D shumidificateur 650 Ponceuse disque 9 po 1200 Coupe bordures 500 Couverture chauffante lectrique 400 Cloueuse lectrique 1200 Cuisini re lectrique par l ment 1500 Po le lectrique cas au eRRRERR s 1250 UC REP 700 Ventilateur de chaudi re 0 6 HP 875 Ouvre porte de garage 500 750 S che cheveux 1200 P rc use MN dais 250 1 100 ILI EL 450 GIG Rs A D M 500 1200 POMPE a aci tradi 800 Tondeuse
7. Battery cable from the battery terminal whichever is easier before transporting the generator SAFETY RULES Portable Generator System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS The manufacturer suggests that these rules for safe operation be copied and posted near the unit s installation site Safety should be stressed to all operators and potential operators of this equipment EXHAUST amp LOCATION HAZARDS Never operate in an enclosed area or indoors NEVER use in the home or in partly enclosed areas such as garages even if doors and windows are open ONLY use outdoors and far from open windows doors vents and in an area that will not accumulate deadly exhaust g r l in TUER EN QUELQU lows are open Only use OUTSIDE and far away from u d un garage M ME SI les portes et les fen tres sont ouvertes Utiliser s et ventilations NE JAMAIS uti UNIQUEMENT NUNCA lo use dentro de un y lejos de ventanas puertas The engine exhaust fumes contain carbon monoxide which can you cannot see or smell This poisonous gas if breathed in sufficient concentrations can cause unconsciousness or even death Adequate unobstructed flow of cooling and ventilating air is critical to correct generator operation Do not alter the installation or permit even partial blockage of ventilation provisions as this can seriously affect safe operation of the generator The generator MUST be operated outdoors This ex
8. 240 V 7 8 KW 25 A 30 A Courant 120 VU 20 A Fr quence nominale 60 Hz 3 600 RPM 0 Monophas e Le wattage et le courant maximum sont soumis et limit s par ces facteurs tels que le contenu en Btu de carburant la temp rature ambiante l altitude l tat du moteur etc La puissance maximale diminue d environ 3 5 pour chaque tranche de 1 000 pieds au dessus du niveau de la mer et diminuera galement d environ 1 pour chaque tranche de 6 C 10 F au dessus de 16 C 60 F de temp rature ambiante 3 2 2 CARACT RISTIQUES TECHNIQUES DU MOTEUR Cheval vapeur nominal 3 600 14 5 0 410 cc Type de bougie d allumage Champion RC14YC ou quivalent Ecartement de bougie d allumage 0 030 pouces ou 0 76 mm Capacit d essence 8 gallons U S Type d huile Voir tableau dans la section Ajout de l huile de moteur Capacit d huile avec changement de filtre 1 5 Qts sans changement de filtre 1 2 Qts Temps d ex cution consommation d essence 1 2 10 heures 0 8 gallons par heure Certifi mission de cat gorie Il MAINTENANCE 20 3 3 RECOMMANDATIONS G N RALES La garantie du g n rateur ne couvre pas les l ments qui ont t soumis un abus ou une n gligence de l op rateur Afin de r
9. Ne jamais remplir le r servoir d essence l int rieur Respecter toutes les lois r glementant le stockage et la manipulation de l essence Ne pas trop remplir le r servoir d essence Toujours laisser de la place pour l expansion du carburant En cas de suremplissage du r servoir le carburant peut d border sur un moteur chaud et entra ner un INCENDIE ou une EXPLOSION NE JAMAIS ranger le moteur avec un r servoir rempli d essence l int rieur ou dans des zones ferm es et faiblement a r es o des fum es peuvent atteindre une flamme nue des tincelles ou une veilleuse telle qu il y en a sur une chaudi re un chauffe eau un s che linge ou d autres appareils fonctionnant au gaz tant donn que cela peut entra ner un INCENDIE ou une EXPLOSION Permettre l appareil de se refroidir avant de stockage Nettoyer imm diatement toute claboussure de carburant ou d huile S assurer qu aucune mati re combustible ne reste sur ou proximit du g n rateur Garder l espace environnant du g n rateur propre et sans d bris et garder un jeu de cinq 5 pieds sur tous les c t s afin de permettre une a ration adapt e du g n rateur Ne pas faire fonctionner le g n rateur si des dispositifs lectriques branch s surchauffent si la puissance lectrique est perdue si le moteur ou le g n rateur fait des tincelles si des flammes ou de la fum e sont d tect es alors que l unit fonctionne Garder un extincteur
10. gazon 1200 DUI c LEE 100 Four micro ondes 700 1 000 Refroidisseur de 1100 Br leur mazout de chaudi re 300 Radiateur mazout 140 000 Btu 400 Radiateur mazout 85 000 Btu 225 Radiateur mazout 30 000 Btu 150 Pistolet peinture sans air 0 3 HP 600 Pistolet peinture sans air portable 150 Radio eee errorae aspasia ayapana 50 200 Remo a 25e rU pvp hr ek des 700 Cocotte mijoteuse 200 Pompe immerg e 1 5 2800 FONCTIONNEMENT Section 2 Fonctionnement ix G n rateur portable immerg e 1 HP 2000 Pompe immerg e 0 5 HP eme pasu 1500 Pompe de vidange 800 1 050 Scie circulaire table 10 po 1 750 2 000 T IGVISIOTIL ds 200 a 500 Grille pain 1 000 1 650 Coupe mauvaises herbes 500 Laisser 3 fois les watts indiqu s pour le d marrage de ces dispositifs 2 7 AVANT LE D MARRAGE DU G N RATEUR Avant de faire fonctionner le g n rateur de l huile de moteur et de l essence devront tre ajout s de la fa on suivante 2 7 1 AJOUT
11. jusqu ce que le moteur fonctionne doucement et ensuite sur la position Run Marche 47 FONCTIONNEMENT Section 2 Fonctionnement ix G n rateur portable Ce g n rateur est galement quip d un lanceur rappel manuel qui peut tre utilis en cas de d chargement de la batterie REMARQUE L interrupteur doit tre en position RUN Marche Pour d marrer manuellement attraper fermement la poign e de rappel et tirer jusqu ce qu une r sistance se fasse sentir Remonter rapidement et d marrer le moteur Puis suivre la m me s quence de l trangleur REMARQUE Si le moteur chauffe mais ne continue pas fonctionner mettre le levier de l trangleur sur Full Choke Etrangleur plein et r p ter les instructions de d marrage Sch ma 15 Position de l trangleur trangleur ss E Interrupteur Start Run Stop D marrage Marche Arr t 6 IMPORTANT Ne pas surcharger le g n rateur Aussi ne pas surcharger les prises individuelles du panneau Ces prises sont prot g es contre la surcharge avec des disjoncteurs de type pousser pour r enclencher Si la valeur nominale d amp rage d un disjoncteur est d pass e ce disjoncteur s ouvre et la puissance lectrique de cette prise est perdue Lire attentivement la section Ne pas surcharger le g n rateur 2 10 ARR T DU MOTEUR Arr ter toutes les charges puis d brancher les charges lectriques des p
12. Mantenga las manos pies ropa etc lejos de las correas de tracci n ventiladores y otras partes m viles o calientes Nunca retire ninguna protecci n de ventilador mientras la unida est operando Algunas partes de este generador se calientan mucho durante la operaci n Mantenga distancia del generador hasta que se haya enfriado para evitar quemaduras severas NO opere el generador en la lluvia No altere la construcci n del generador ni cambie los controles de modo que puedan crear una condici n de operaci n no segura e Nunca arranque o detenga la unidad con cargas el ctricas conectadas a las tomas Y con dispositivos conectados y encendidos Arranque el motor y deje que se estabilice antes de conectar las cargas el ctricas Desconecte todas las cargas el ctricas antes de apagar el generador No inserte objetos a trav s de las ranuras de enfriamiento de la unidad Al trabajar con este equipo mant ngase alerta en todo momento Nunca trabaje en el equipo cuando est f sica mentalmente fatigado Nunca use el generador ni alguna de sus partes como escal n Pararse sobre la unidad puede tensar y romper partes y puede traer como resultado condiciones peligrosas de operaci n como escape de gases combustible o aceite En los modelos de arranque el ctrico desconecte el cable de bater a POSITIVO del arrancador del motor O el cable de bater a NEGATIVO del terminal de la bater a lo que sea m s f ci
13. Revise la abertura de la v lvula Preste servicio al filtro de aire Cambie las buj as Cada vez que lo utilice Cada 100 horas o cada estaci n Cada estaci n Cada 200 horas o cada estaci n Cada estaci n Cambie el aceite despu s de las primeras 30 horas de funcionamiento y luego cada estaci n Cambie el aceite y el filtro cada mes cuando utilice el equipo bajo cargas fuertes o en temperaturas altas Limpie m s a menudo si el equipo trabaja en condiciones de suciedad o polvo Reemplace las piezas del filtro de aire si no pueden limpiarse adecuadamente Revise la abertura de la v lvula y ajuste si fuese necesario despu s de las primeras 50 horas de funcionamiento y cada 100 despu s 3 2 ESPECIFICACIONES DEL PRODUCTO 3 2 1 ESPECIFICACIONES DEL GENERADOR Potencia nominal oasis 7 0 8 0 kw Elevaci n de potencia al arranque 8 7 12 0 kW Voltaje nominal AG iecit rires 120 240 Carga nominal M x AC Corriente a 240V 7 0 8 0 KW 25 Amp 30 Amp Gorriente a 120V ences e iere tae 20 Amp Frecuencia nominal 60 Hz a 3600 RPM cote sees cette IM ICI Monofasica El vataje m ximo y la corriente est n sujetos y limitados por factores tales como el contenido de Btu del combustible la temperatura ambiente la altitud las condiciones del motor etc La potencia m xima disminuye aproximadamente un 3 5 por cada 1 000
14. Using a generator indoors CAN KILL Utiliser un g n rateur l int rieur PEUT Si usa un generador en interiores YOU IN MINUTES VOUS TUER EN QUELQUES MINUTES MORIR EN POCOS MINUTOS Generator exhaust contains carbon Les gaz d chappement du g n rateur El escape del generador contiene monoxide This is a poison you contiennent du monoxyde de carbone mon xido de carbono Es un veneno cannot see or smell C est un gaz toxique invisible et inodore que no tiene olor ni se puede ver NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents NE JAMAIS utiliser l int rieur d une maison ou d un garage MEME S les portes et les fen tres sont ouvertes Utiliser UNIQUEMENT l EXT RIEUR et loin des fen tres portes et ventilations NUNCA lo use dentro de una casa o garaje AUN si las puertas y ventanas est n abiertas S lo selo EN EXTERIORES y lejos de ventanas puertas y ductos de ventilaci n Les fum es d chappement du moteur contiennent du monoxyde de carbone qui peut s av rer MORTEL Ce gaz dangereux s il est respir en concentrations suffisantes peut entrainer une perte de conscience ou m me la mort Un d bit appropri non obstru d air de refroidissement et de ventilation est important pour corriger le fonctionnement du g n rateur Ne pas modifier l installation ou ne pas laisser m me un blocage partiel de l alimentation de
15. a en el arranque Instale y ajuste la buj a No conecte el cable de buj a Limpie las otras superficies del generador Revise que las aberturas y ranuras de aire de ventilaci n en el generador est n abiertas y sin obstrucciones e Guarde la unidad en un lugar limpio y seco 3 8 OTROS CONSEJOS TILES PARA EL ALMACENAJE No guarde gasolina de una estaci n a otra e Cambie el envase de la gasolina si comienza a oxidarse El xido y o el sucio en la gasolina ocasionar n problemas con el sistema del carburador y de combustible Si fuese posible guarde la unidad en interiores y c brala para protegerla del polvo y del sucio VACIE EL TANQUE DE COMBUSTIBLE Si no es pr ctico vaciar el tanque de combustible y la unidad debe almacenarse durante alg n tiempo utilice un estabilizador de combustible disponible en el mercado y a dalo a la gasolina para prolongar la vida de la gasolina Cubra la unidad con una cubierta protectora adecuada que no retenga TES NUNCA cubra el generador mientras el motor y el rea de escape est n tibios Secci n 4 Soluci n de problemas SOLUCI N DE PROBLEMAS Sistema de generador port til 4 1 GU A PARA LA SOLUCI N DE PROBLEMAS PROBLEMA El motor est trabajando pero no hay salida de AC El motor trabaja bien pero se atasca cuando se le conectan cargas El motor no arranca o arranca y trabaja con dificultad El motor se apaga mientras
16. circuit de carburant d un moteur pendant le stockage de celui ci Afin d viter tout probl me avec le moteur le circuit de carburant doit tre vid avant le stockage du moteur si celui ci est d au moins 30 jours Pour cela e Vidanger le r servoir d essence de tout le carburant qu il contient Dd A Vider l essence dans des conteneurs adapt s situ s l ext rieur loin de toute flamme nue S assurer que le moteur est froid Ne pas fumer e D marrer et faire fonctionner le moteur jusqu ce qu il s arr te suite une panne d essence e Laisser le moteur refroidir puis vider l huile du carter Remplir jusqu au niveau recommand e Retirer la bougie d allumage et verser environ 0 5 onces 15 ml d huile pour moteur dans le cylindre Couvrir le trou de la bougie d allumage avec un chiffon Tirer plusieurs fois le lanceur rappel pour lubrifier les segments de piston et l al sage du cylindre 52 ATTENTION viter d asperger partir des trous de la bougie d allumage lorsque le moteur tourne e Remettre et serrer la bougie d allumage Ne pas brancher le fil de bougie e Nettoyer les surfaces externes du g n rateur V rifier que les fentes de refroidissement et les orifices du g n rateur sont ouverts et non obstru s 3 8 AUTRES CONSEILS DE STOCKAGE Ne pas stocker l essence d une saison sur l autre e Remplacer le bidon d essence s il commence rouiller De la rouille e
17. n rateur Si des problemes se pr sentent lors du montage du g n rateur merci d appeler la ligne d assistance pour les g n rateurs au 1 888 436 3722 1 2 1 MONTAGE DU KIT D ACCESSOIRES Les roues sont con ues dans l unit pour am liorer consid rablement la portabilit du g n rateur REMARQUE Les roues ne sont pas con ues pour une utilisation sur la route 1 Merci de vous reporter au Sch ma 1 et d installer les roues comme suit Faire glisser le d axe de 0 5 po travers la rondelle de 0 5 po la roue et le support de la roue sur le b ti e Installer les crous collet de blocage de 0 5 po sur le boulon collet de 0 5 po 2 Se reporter au Sch ma 1 et installer le pied du b ti le support du pied et les pieds en caoutchouc comme indiqu Faire glisser l axe des pieds en caoutchouc travers le support du pied et le pied du b ti Installer les crous collet de blocage de 0 31 po faire glisser le boulon de 0 31 po travers la rondelle plate de 0 31 po puis travers les trous dans le longeron de cadre de ch ssis e Faire glisser le pied du b ti sur les boulons de 0 31 po Installer les crous collet de blocage de 0 31 po 3 Merci de vous reporter au Sch ma 2 et d installer les poign es comme indiqu Retirer les boulons t te courb e et les crous borgnes Les crous borgnes seront r utilis s 42 e Faire glisser la poign e sur le tube du b ti en align
18. tiene salida Lea atentamente No sobrecargue el generador 2 9 C MO ARRANCAR LOS MOTORES DE ARRANQUE ELECTRICO ADVERTENCIA Nunca arranque ni pare un motor con dispositivos el ctricos enchufados a los tomacorrientes Y los dispositivos encendidos Desenchufe todas las cargas el ctricas de los tomacorrientes de la unidad antes de arrancar el motor Cerci rese de que la unidad est en posici n nivelada Abra la v lvula de corte del combustible Figuras 12 y 14 Mueva la perilla CHOKE reguladora de flujo hacia afuera hasta la posici n Full choke Figura 15 Figura 14 V lvula de corte del combustible Encendido Apagado 0 L gt AAN on OFFS Corte de combustible Para arrancar el motor presione y sostenga el interruptor Start Run Stop arranque marcha parada en la posici n Start El motor har el intento de arrancar Cuando el motor arranque libere el interruptor en la posici n Run Cuando el motor arranque mueva la perilla reguladora de flujo a la posici n 1 2 CHOKE hasta que el motor trabaje suavemente y luego totalmente a la posici n Run Si el motor falla mueva la perilla reguladora de flujo nuevamente a la posici n 1 2 Choke hasta que el motor trabaje suavemente y luego a la posici n Run 29 FUNCIONAMIENTO Este generador tambi n est equipado con un arranque de retroceso manual que puede utilizarse si la
19. unidades de encendido el ctrico nicamente 20 Secci n 3 Mantenimiento ssssssssssrersesrrsrsssrnnensnnnn 31 3 1 Programaci n de 31 3 2 Especificaciones del 31 3 2 1 Especificaciones del 31 3 2 2 Especificaciones del motor 31 3 3 Recomendaciones 31 3 3 1 Mantenimiento del generador 31 3 3 2 Limpieza del 31 3 8 3 Mantenimiento del motor aa 31 3 89 4 Revisi n del nivel de 32 3 8 5 Cambio de 32 3 3 6 Cambio de la 32 3 3 7 Reemplazo de la bater a 32 3 4 Servicio del filtro de aire 32 3 5 Limpieza de la pantalla del parachispas 33 3 6 C mo ajustar la abertura de la v lvula 33 3 7 Almacenaje por per odos 005 34 3 8 Otros consejos tiles para el almacenaje 34 Secci n 4 Soluci n de problemas 35 4 1 Guia para la soluci n de 5
20. 1 2 Flange Bolt 2 Refer to Figure 1 and install Frame Foot Foot Support and Rubber Feet as shown Slide Rubber Foot stud through the Foot Support and Frame Foot Install 5 16 Locking Flange Nuts Slide 5 16 Bolt through 5 16 Flat Washer and then through holes in Frame Rail eSlide Frame Foot onto 5 16 Bolts Install 5 16 Locking Flange Nuts 3 Refer to Figure 2 and install Handles as shown Remove top Curved Head Bolts and Cap Nuts Cap Nuts will be re used Slide Handle Assembly over Frame Tube aligning 2 holes e Slide 5 16 Carriage Bolts through Install 5 16 Cap Nuts Figure 1 Wheel Assembly 2X LOCK NUT 1 2 2X BOLT 5 16 2X WHEEL 2X FLAT WASHER 1 2 2X AXLE FOOT FOOT SUPPORT i X FLANGE NUT 5 16 2X RUBBER Figure 2 Install Handle Kit 2X FLAT WASHER 5 16 REMOVE DISCARD CURVED HEAD BOLT REMOVE AND RE USE NUT HANDLE ASSEMBLY SCALE 0200 1 2 0 STARTER CONNECTION ELECTRIC START ONLY The unit has been deliberately shipped with the starter cable disconnected To connect starter 1 Locate starter cable a hang tag is attached as shown in Figure 3 2 Pull vinyl boot back onto starter cable 3 Remove nut and washer from starter post 4 Put starter cable onto post and re install washer and nut Figure 3 Starter Connection 2 1 KNOW THE GENERATO
21. 1000 Lavadora de ropa 1150 Lijadora de banda 3 pulgadas 7 6 1000 Lijadora de banda 9 pulgadas 22 9 1200 Llave de Impacto scies eec me eR RR 500 Manta el ctrica me ee seats 400 MOtOSIGIT e sex saws a bb a ek e wama n rn ved s 1200 Olla de cocci n lenta 200 Pistola el ctrica para clavos 1200 arn s 1200 Podadora de c sped va uuu rrr eS REESE 1200 Podadora de malezas 500 Podadora de setos 450 Quemador de aceite del sistema de calefacci n 300 E Seles tases toate moine 50 a 200 Mudo TET 700 RIZO pee ono I eU Aa he n 700 Rociador de pintura sin aire 1 3 HP 600 Rociador de pintura sin aire de 150 Sart n el ctrico 1250 Secador de pelo 1200 Secadora de ropa gas 700 Secadora de ropa el ctrica 5750 Sierra circular 6 1 2 pulgadas 16 5 cm 800 a 1000 27 FUNCIONAMIENTO DD Secci n 2 Funcionamiento Sistema de generador port til Sierra de mesa 10 pulgadas 25 4 cm 1750 a 2000 Taladro JEMAND gt sotto rentes 250 a 1100 1 0101907
22. 12 Tapa de gasolina Conducto para llenar combustible 13 Medidor de gasolina Muestra el nivel de combustible del tanque 14 Conducto para aceite A ada aceite aqu 15 Arranque por retroceso Utilice para arrancar el motor manualmente 16 Corte de combustible V lvula entre el tanque de combustible y el carburador 17 Drenaje de aceite Utilice para vaciar el aceite del motor 18 Toma para el cargador de bater as Este recept culo le permite recargar la bater a de 12 voltios DC que se proporciona con el cargador con adaptador para 12 voltios el cual se suministra en la caja de accesorios Detr s de la toma del cargador de bater a se encuentra un fusible de 1 50 Amp en l nea el cual est en el panel de control para proteger la bater a 19 Bater a Alimenta el arranque el ctrico Unidades de arranque el ctrico nicamente Secci n 2 Funcionamiento Sistema de generador port til Figura 5 Controles del generador ESOO XA UN LOU DETALLE A LADO 25 FUNCIONAMIENTO 2 2 CONTADOR HORARIO El contador horario lleva la cuenta de las horas de funcionamiento para la programaci n del mantenimiento Cada 100 horas aparecer un mensaje CHG OIL El mensaje destellar una hora antes y una hora despu s de cada intervalo de 100 horas de nuevo proporcionando un espacio de dos horas para efectuar el servicio Este mensaje comenzar a destellar realme
23. 2 Prise 120 240 V c a 30 44 2 4 Utilisation du 44 2 41 Mise la terre du g n rateur 44 2 4 2 Branchement des charges lectriques 45 2 5 Ne pas surcharger le 45 2 6 Guide de r f rence de 45 2 7 Avant le d marrage du g n rateur 46 2 7 1 Ajout de l huile de moteur o 46 2 7 2 Ajout de 5 46 2 8 D marrage des moteurs d marrage manuel 47 2 9 D marrage des moteurs d marrage lectrique 47 2 10 Arr t du moteur 48 2 11 Syst me d arr t de bas niveau d huile 48 2 11 1 D tection de bas niveau d huile 48 2 12 Chargement de la batterie Unit s d marrage lectrique 48 38 Section 3 49 3 1 Programme de 49 3 2 Caract ristiques techniques des produits 49 3 2 1 Caract ristiques techniques du g n rateur 49 3 2 2 Caract ristiques techniques du moteur 49
24. 3 3 Recommandations g n rales 49 3 3 1 Maintenance du 49 3 3 2 Nettoyage du g n rateur 49 3 3 3 Maintenance du 49 3 3 4 V rification du niveau d huile 50 3 8 5 Changement de l huile naasnaaesaiaeeaee aeee 50 3 3 6 Remplacement des bougies d allumage 50 3 3 7 Remplacement de la batterie 50 3 4 Entretien du filtre air 50 3 5 Nettoyage de l cran pare tincelles 51 3 6 R glage du jeu des 51 3 7 Stockage long terme 52 3 8 Autres conseils de stockage 52 Section 4 D pannage 53 4 1 Guide de d pannage 53 Section 5 Couverture verso INTRODUCTION Nous vous remercions d avoir achet ce modele fabriqu par Generac Power Systems Inc Ce mod le est un g n rateur entra n par moteur compact haute performance refroidi a l ai con u pour fournir l alimentation lectrique afin de faire fonctionner les charges lectriques lorsqu aucun r seau lectrique n est disponible ou a la place du r seau en raison d une coupure de courant L
25. CLEANER The engine will not run properly and may be damaged if using a dirty air cleaner Clean or replace the air cleaner paper filter once a year Figure 19 Clean or replace more often if operating under dusty conditions Figure 19 Air Cleaner To clean or replace paper air filter Remove air cleaner cover and remove paper filter Clean paper filter by tapping it gently on a solid surface If the filter is too dirty replace it with a new one Dispose of the old filter properly Clean air cleaner cover then insert new paper filter into the base of the air cleaner Re install air cleaner cover NOTE To order a new air filter please contact the nearest authorized service center at 1 800 333 1322 3 0 CLEAN SPARK ARRESTOR SCREEN The engine exhaust muffler has a spark arrestor screen Inspect and clean the screen at least once each year Figure 20 If unit is used regularly inspect and clean more often NOTE If using the generator on any forest covered brush covered or grass covered unimproved land it must equipped with a spark arrestor The spark arrestor must be maintained in good condition by the owner operator Clean and inspect the spark arrestor as follows Remove muffler heat shield from muffler removing four screws Remove spark arrestor from muffler removing four screws Inspect screen and replace if torn perforated or otherwise damaged DO NOT USE a defective screen If sc
26. FILL CRANKCASE TO THE BOTTOM OF THESE THREADS WITH THE RECOMMENDED ENGINE OIL 27 2 ADDING GASOLINE A DANI A Never fill fuel tank indoors Avoid spilling gasoline on hot engine Allow engine to cool entirely before adding fuel Never fill fuel tank when engine is running or hot DO NOT light a cigarette or smoke when filling the fuel tank Gasoline is highly flammable and its vapors are explosive Do not overfill the fuel tank Always leave room for fuel expansion If the fuel tank is overfilled fuel can over flow onto a hot engine and cause fire or an explosion Wipe up any spilled fuel immediately Use regular UNLEADED gasoline with the generator engine Do not use premium gasoline Do not mix oil with gasoline Clean area around fuel fill cap remove cap Slowly add unleaded regular gasoline to fuel tank Fill to bottom of screen filter Be careful not to overfill Figure 11 Install fuel cap and wipe up any spilled gasoline Figure 11 Fuel Tank Fuel Tank Fuel DO NOT Fill Above Lip IMPORTANT It is important to prevent gum deposits from forming in fuel system parts such as the carburetor fuel hose or tank during storage Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and formatio
27. POSITIF DE LA BATTERIE ROUGE 3 4 ENTRETIEN DU FILTRE AIR Le moteur ne fonctionnera pas correctement et pourra tre endommag en cas d utilisation d un filtre air sale Nettoyer ou remplacer le papier du filtre air une fois par an Sch ma 19 Il sera n cessaire de le nettoyer ou de le remplacer plus souvent en cas de fonctionnement dans des conditions de salet Sch ma 19 Filtre air COUVERCLE Pour nettoyer ou remplacer le papier du filtre a air Retirer le couvercle du filtre air et retirer le filtre en papier Nettoyer le filtre en papier en le tapant l gerement sur une surface solide Si le filtre est trop sale il est n cessaire de le remplacer Jeter l ancien filtre de mani re adapt e Nettoyer le couvercle du filtre air puis ins rer le nouveau filtre en papier dans la base du filtre air Remettre le couvercle du filtre air en place REMARQUE Pour commander un nouveau filtre air merci de contacter le centre d entretien agr le plus proche au 1 800 333 1322 3 5 NETTOYAGE DE L CRAN PARE TINCELLES Le silencieux du pot d chappement du moteur est quip d un cran pare tincelles Inspecter et nettoyer l cran au minimum une fois par an Sch ma 20 Si l unit fonctionne r guli rement inspecter et nettoyer l cran plus souvent REMARQUE Si le g n rateur est utilis sur un terrain brut couvert d arbres de buissons ou d herb
28. Systems Inc Generac warrants its GP Series generators will be free from defects in materials and workmanship for the items and period set forth below Generac will at its option repair or replace any part which upon examination inspection and testing by Generac or a Generac Authorized Warranty Service Dealer is found to be defective Any equipment that the purchaser owner claims to be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Dealer All transportation costs under the warranty including return to the factory are to be borne and prepaid by the purchaser owner This warranty applies only to Generac GP Series portable generators and is not transferable from original purchaser Save your proof of purchase receipt If you do not provide proof of the initial purchase date the manufacturer s shipping date of the product will be used to determine the warranty period WARRANTY SCHEDULE Consumer applications are warranted for two 2 years Commercial and Rental applications are warranted for one 1 year or 1000 hours maximum whichever comes first CONSUMER APPLICATION YEARS ONE and TWO 100 one hundred percent coverage on Labor and Part s listed proof of purchase and maintenance is required Engine All Components Alternator All Components COMMERCIAL RENTAL APPLICATION YEAR ONE 100 one hundred percent coverage on Labor and Part s listed proof of purchase and maintenance is
29. V c a 20 A Fournit une alimentation lectrique pour le fonctionnement d un clairage lectrique d appareils d outils et de charges de moteur 120 V c a 20 A monophas 60 Hz Prise verrouillage 120 240 V c a 30 A Fournit une alimentation lectrique pour le fonctionnement d un clairage lectrique d appareils d outils et de charges de moteur 120 V et ou 240 V c a 30 monophas 60 Hz Disjoncteurs c a Chaque prise est fournie avec un disjoncteur de type pousser pour r enclencher pour prot ger le g n rateur contre les surcharges lectriques Sch ma 4 Panneau de commande Horom tre Rel ve les heures de fonctionnement Filtre air Filtre l air aspir par le moteur trangleur Utilis au d marrage d un moteur froid R servoir d essence Le r servoir peut contenir 6 6 gallons U S d essence Borne de mise la terre Relie le g n rateur a une terre approuv e Voir la section Mise la terre du g n rateur pour plus d informations Interrupteur Start Run Stop D marrage Marche Arr t Contr le le fonctionnement du g n rateur 10 Pot d chappement Rend silencieux le moteur FONCTIONNEMENT OD Section 2 Fonctionnement G n rateur portable Poign es Pivoter et r tracter pour le stockage Appuyer sur le bouton ressort pour d placer les poign es Chapeau de gaz assis
30. alternate with elapsed time in hours and tenths The hours will flash four times then alternate with the maintenance message four times until the meter resets itself e 100 hours CHG OIL Oil Change Interval Every 100 hrs 200 hours SVC Air Filter Interval Every 200 hrs 2 3 CORD SETS AND CONNECTION PLUGS 2 3 1 120 VAC 20 DUPLEX RECEPTACLE This is a 120 Volt outlet protected against overload by a 20 Amp push to reset circuit breaker Figure 7 Use each socket to power 120 Volt AC single phase 60 Hz electrical loads requiring up to a combined 2400 watts 2 4 kW or 20 Amps of current Use only high quality well insulated 3 wire grounded cord sets rated for 125 Volts at 20 Amps or greater Keep extension cords as short as possible preferably less than 15 feet long to prevent voltage drop and possible overheating of wires Figure 7 120 Volt AC 20 Amp Duplex Receptacle 2 3 2 120 240 VAC 30 AMP RECEPTACLE Use a NEMA L14 30 plug with this receptacle rotate to lock unlock Connect a suitable 4 wire grounded cord set to the plug and to the desired load The cord set should be rated for 250 Volts AC at 30 Amps or greater Figure 8 Figure 8 120 240 VAC 30 Amp Receptacle 120V 240V 30A Use this receptacle to operate 120 Volt AC 60 Hz single phase loads requiring up to 3600 watts 3 6 kW of power at 30 Amps or 240 Volt AC 60 Hz single phase loads requiring up to 7200 watts 7 2 kW of p
31. bater a est descargada NOTA El interruptor deber estar en la posici n RUN Para arrancar manualmente agarre firmemente la manija de retroceso y hale lentamente hasta que sienta que aumenta la resistencia Hale r pidamente hacia arriba y hacia afuera para arrancar el motor Luego siga la misma secuencia que con la perilla reguladora de flujo NOTA Si el motor echa a andar pero no contin a andando mueva la palanca reguladora de flujo a la posici n Full Choke y repita las instrucciones de arranque Sistema de generador port til Figura 15 Posici n de regulaci n de flujo Reguladora de flujo 0 N IMPORTANTE No sobrecargue el generador Tampoco sobrecargue los tomacorrientes individuales del panel Estos tomacorrientes est n protegidos contra sobrecarga con interruptores de circuito del tipo presione para reiniciar Si se excede la potencia nominal de cualquier interruptor de circuito ese interruptor se abre y ese tomacorriente ya no tiene salida Lea atentamente No sobrecargue el generador 2 10 C MO PARAR EL MOTOR Desconecte todas las cargas luego desenchufe las cargas el ctricas de los tomacorrientes del panel del generador Nunca arranque ni pare un motor con dispositivos el ctricos enchufados a los tomacorrientes ni encendidos Deje que el motor trabaje sin carga durante algunos minutos para estabilizar las temperaturas internas del motor y del generador Cambie
32. chargeur de la batterie BATTERIE ENTR E DU CHARGEUR REMARQUE Ne pas utiliser le chargeur de batterie pendant plus de 48 heures cons cutives 3 1 PROGRAMME DE MAINTENANCE Suivre les intervalles du calendrier Un entretien plus fr quent est n cessaire lors du fonctionnement dans les conditions d favorables indiqu es ci dessous V rifier le niveau d huile Lors de chaque utilisation Changer l huile Toutes les 100 heures ou chaque saison V rifier le jeu des soupapes chaque saison Entretien du filtre air Toutes les 200 heures ou chaque saison Remplacer la bougie d allumage chaque saison t Changer l huile apr s les 30 premi res heures de fonctionnement puis chaque Saison Changer l huile et le filtre huile tous les mois lors du fonctionnement sous une charge lourde ou des temp ratures lev es Nettoyer plus souvent dans des conditions de fonctionnement sales Remplacer les pi ces du filtre air s il est impossible de les nettoyer correctement V rifier le jeu des soupapes et r gler si n cessaire apr s les 50 premi res heures de fonctionnement et toutes les 100 heures par la suite 3 2 CARACT RISTIQUES TECHNIQUES DES PRODUITS 3 2 1 CARACT RISTIQUES TECHNIQUES DU GENERATEUR Puissance nominale 7 8 kW Puissance de 501605100 a 8 7 12 kW Tension c a nominale 120 240 Charge nominale c a max Courant
33. el interruptor Run Stop a la posici n OFF Cierre la v lvula de corte del combustible 2 11 SISTEMA DE APAGADO POR BAJO NIVEL DE ACEITE El motor viene equipado con un sensor que detecta cuando el nivel de aceite est bajo y apaga autom ticamente el motor cuando el nivel de aceite se encuentra por debajo de un nivel espec fico Si el motor se apaga autom ticamente y el tanque de combustible tiene suficiente gasolina revise el nivel de aceite del motor 30 Secci n 2 Funcionamiento 2 11 1 SENSOR DE BAJO NIVEL DE ACEITE Si el sistema detecta un nivel de aceite bajo durante el funcionamiento el motor se apaga El motor no trabajar hasta que se haya llenado el aceite al nivel adecuado 2 12 C MO RECARGAR UNA BATER A UNIDADES DE ENCENDIDO ELECTRICO UNICAMENTE HE Las bater as de acumuladores liberan gases de hidr geno explosivos mientras se est n recargando La mezcla explosiva permanecer alrededor de la bater a por largo tiempo despu s de que se haya cargado Hasta la menor chispa puede encender el gas y provocar una explosi n Dicha explosi n puede destrozar la bater a y provocar ceguera u otras lesiones graves HE AN No permita fumadores llamas expuestas chispas ni cualquier otra fuente de calor cerca de una bater a Utilice gafas protectoras delantal de goma y guantes de goma cuando trabaje cerca de una bater a El fluido electrol tico de la bater a es u
34. el motor se enfr e antes de drenarlo Evite la exposici n prolongada o repetida con el aceite usado Lave meticulosamente las reas expuestas con jab n Esto facilitar drenar el aceite Siga las siguientes instrucciones para cambiar el aceite mientras el motor se encuentre a n tibio e Limpie el rea alrededor del tap n de drenaje de aceite Retire el tap n del motor para drenaje de aceite del motor y el tap n del conducto para aceite a fin de drenarlo completamente en un envase adecuado Cuando haya vaciado completamente el aceite coloque el tap n de drenaje de aceite y apri telo de forma segura Llene el colector de aceite con el aceite recomendado Refi rase a Antes de arrancar el generador para las recomendaciones sobre el aceite e Limpie cualquier resto de aceite que se haya derramado Deseche el aceite usado en un centro de recolecci n adecuado 3 3 6 CAMBIO DE LA BUJ A Utilice la buj a Champion RC14YC o su equivalente Cambie la buj a una vez al a io Esto le ayudar a que el motor arranque m s f cilmente y trabaje mejor 1 Apague el motor y hale el cable de la buj a para retirarlo de la buj a 2 Limpie el rea alrededor de la buj a y ret rela del cabezal del cilindro 3 Coloque el entrehierro de la buj a en 0 70 0 80 mm 0 028 0 031 pulgadas Coloque la buj a con la abertura correcta al cabezal del cilindro Figura 17 Figure 17 Entrehierro de la buj a 32
35. est trabajando El motor se acelera o falla 1 El interruptor de circuito est abierto 2 Conexi n deficiente o juego de cables defectuoso 3 El dispositivo conectado est da ado 4 Falla en el generador 1 Cortocircuito en una carga conectada 2 El generador est sobrecargado 3 La velocidad del motor es demasiado baja 4 Cortocircuito en el generador 1 La v lvula de cierre del combustible est en OFF 2 El filtro de aire est sucio 3 No tiene gasolina 4 Gasolina en malas condiciones 5 El cable de la buj a no est conectado a la buj a 6 Buj a deteriorada 7 Agua en la gasolina 8 Ahogo excesivo 9 Bajo nivel de aceite 10 Mezcla de combustible excesivamente enriquecida 11 V lvula de entrada atascada abierta o cerrada 12 El motor perdi compresi n 1 No tiene gasolina 2 Bajo nivel de aceite 3 Falla en el generador 1 La carga es demasiado grande 2 El filtro de aire est sucio 3 El motor necesita servicio 1 La perilla reguladora de flujo se abre demasiado r pido 2 El carburador trabaja con mezcla demasiado rica o demasiado pobre CORRECCI N 1 Reinicie el interruptor de circuito 2 Revise y repare 3 Conecte otro dispositivo que est en buenas condiciones 4 Contacte el centro de servicio autorizado 1 Desconecte la carga el ctrica en cortocircuito 2 Refi rase a No sobrecargue el generador 3 Contacte el centro de serv
36. fil de bougie est d branch de la bougie d allumage et ne g ne pas Retirer la bougie d allumage Enlever les quatre vis retenant le coin de la soupape e S assurer que le piston est au Point Mort Haut PMH de sa course de compression les deux soupapes ferm es Pour mettre le piston au PMH retirer la grille d entr e devant le moteur afin d acc der l crou du volant Utiliser une grande douille et une cl pipe pour faire tourner l crou et donc le moteur dans le sens des aiguilles d une montre tout en regardant le piston travers le trou de la bougie d allumage Le piston doit monter et descendre Le piston est au PMH lorsqu il a atteint le point le plus haut de sa course ns rer un calibre d paisseur de 0 002 0 004 pouces 0 05 0 1 mm entre le culbuteur et la tige de soupape Le jeu est correct lorsque l on sent un l ger glissement lors du d placement du calibre vers l avant et l arri re Si le jeu est trop l che ou serr il est n cessaire de r gler les culbuteurs Pour r gler le jeu des soupapes Desserrer l crou de blocage du culbuteur Sch ma 21 Utiliser une cl hexagonale de 10 mm pour faire tourner l axe de l articulation rotule tout en v rifiant le jeu entre le culbuteur et la tige de soupape avec un calibre d paisseur Le jeu correct est de 0 002 0 004 pouces 0 05 0 1 mm Section 3 Maintenance G n rateur portable Sch ma 21 R glage du jeu des soupapes Axe de l
37. gasoline check engine oil level 10 2 11 1 SENSING LOW OIL LEVEL If the system senses a low oil level during operation the engine shuts down The engine will not run until the oil has been refilled to the proper level 2 12 CHARGING THE BATTERY ELECTRIC START UNITS ONLY A DAN A A Storage batteries give off explosive hydrogen gas while recharging An explosive mixture will remain around the battery for a long time after it has been charged The slightest spark can ignite the hydrogen and cause an explosion Such an explosion can shatter the battery and cause blindness or other serious injury DIG A AN Do not permit smoking open flame sparks or any other source of heat around a battery Wear protective goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an extremely corrosive sulfuric acid solution that can cause severe burns If spill occurs flush area with clear water immediately NOTE The battery shipped with the generator has been fully charged A battery may lose some of its charge when not in use for prolonged periods of time If the battery is unable to crank the engine plug in the 12V charger included in the accessory box see section Charging the Battery RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY Use battery charger plug to keep the battery charged and ready for use Battery charging should be done in a dry location 1 Plug c
38. is running too rich or too lean CORRECTION 1 Reset circuit breaker 2 Check and repair 3 Connect another device that is in good condition 4 Contact Authorized Service Facility 1 Disconnect shorted electrical load 2 See Don t Overload the Generator 3 Contact Authorized Service Facility 4 Contact Authorized Service Facility Turn Fuel Shut off to ON Clean or replace air filter Fill fuel tank Drain fuel tank and fill with fresh fuel Connect wire to spark plug Replace spark plug Drain fuel tank fill with fresh fuel Put choke knob to No Choke position 9 Fill crankcase to proper level 10 Contact Authorized Service Facility 11 Contact Authorized Service Facility 12 Contact Authorized Service Facility M OO WD 1 Fill fuel tank 2 Fill crankcase to proper level 3 Contact Authorized Service Facility 1 Reduce load see Don t Overload the Generator 2 Clean or replace air filter 3 Contact Authorized Service Facility 1 Move choke to halfway position until engine runs smoothly 2 Contact Authorized Service Facility 15 NOTES 16 Section 5 Notes Section 5 Notes NOTES 17 Section 6 Warranty WARRANTY Portable Generator System GENERAC POWER SYSTEMS TWO YEAR LIMITED WARRANTY FOR GP SERIES PORTABLE GENERATORS For a period of two years from the date of original sale Generac Power
39. la posici n ON encendido Figura 13 Hale la perilla CHOKE regulaci n de flujo hacia afuera hasta la posici n FULL CHOKE Figura 13 Para arrancar el motor agarre firmemente la manija de retroceso y hale lentamente hasta que sienta que aumenta la resistencia Hale hacia arriba y hacia afuera r pidamente Cuando el motor arranque mueva la perilla reguladora de flujo a la posici n 1 2 CHOKE hasta que el motor trabaje suavemente y luego totalmente a la posici n RUN Si el motor falla mueva la perilla reguladora de flujo nuevamente a la posici n 1 2 CHOKE hasta que el motor trabaje suavemente y luego totalmente a la posici n RUN Figura 12 V lvula de corte del combustible CORTE DE COMBUSTIBLE f NOTA Si el motor echa a andar pero no contin a andando mueva la palanca reguladora de flujo a la posici n FULL CH0KE y repita las instrucciones de arranque Secci n 2 Funcionamiento FUNCIONAMIENTO Sistema de generador port til ix Figura 13 Posici n de regulaci n de flujo Reguladora de flujo D IMPORTANTE No sobrecargue el generador Tampoco sobrecargue los tomacorrientes individuales del panel Estos tomacorrientes est n protegidos contra sobrecarga con interruptores de circuito del tipo presione para reiniciar Si se excede la potencia nominal de cualquier interruptor de circuito ese interruptor se abre y ese tomacorriente ya no
40. manual and thoroughly understand all instructions before using the equipment We also strongly recommend instructing other users to properly start and operate the unit This prepares them if they need to operate the equipment in an emergency The generator can operate safely efficiently and reliably only if it is properly located operated and maintained Before operating or servicing the generator Become familiar with and strictly adhere to all local state and national codes and regulations e Study all safety warnings in this manual and on the product carefully Become familiar with this manual and the unit before use The manufacturer cannot anticipate every possible circumstance that might involve a hazard The warnings in this manual and on tags and decals affixed to the unit are therefore not all inclusive If using a procedure work method or operating technique that the manufacturer does not specifically recommend ensure that it is safe for others Also make sure the procedure work method or operating technique utilized does not render the generator unsafe THE INFORMATION CONTAINED HEREIN WAS BASED ON MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT ANY TIME SAFETY RULES Throughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular op
41. pies 305 m sobre el nivel del mar y tambi n disminuir aproximadamente 1 por cada 6 C 10 F sobre 16 C 60 F de temperatura ambiente 3 2 2 ESPECIFICACIONES DEL MOTOR Potencia nominal en caballos de fuerza a 3600 RPM 14 5 Desplazamiento 410 cm Tipo de bujia Champion RC14YC o equivalente Entrehierro de la buj a 5 0 6 5 KW 0 030 o 0 76 mm Capacidad de gasolina 8 galones EE UU 31 1 1 Tipo de aceite Refi rase a la tabla en Antes de arrancar el generador Capacidad de aceite con cambio del filtro 1 5 cuartos de gal n sin cambio del filtro 1 2 cuartos de gal n Tiempo de uso Consumo de combustible 2 carga 10 Horas 0 80 gal h Emisi n certificada Clase MANTENIMIENTO 20 Secci n 3 Mantenimiento Sistema de generador port til 3 3 RECOMENDACIONES GENERALES La garant a del generador no ampara art culos que hayan estado sujetos a abuso o negligencia por parte del operador Para recibir el amparo total de la garant a el operador deber mantener el generador como se ha indicado en este manual Deber n efectuarse algunos ajustes peri dicamente para brindar mantenimiento adecuado al generador Todos los ajustes en la secci n de Mantenimiento de este manual deber n efectuarse al menos una vez en cada estaci n Observe las indi
42. potentielle des c bles Sch ma 7 Prise double 120 V c a 20 A 44 2 3 2 PRISE 120 240 V C A 30 A Utiliser une fiche NEMA L14 30 avec cette prise tourner pour verrouiller d verrouiller Brancher un cordon 4 fils avec mise la terre adapt la prise et la charge souhait e Le cordon doit tre congu pour 250 V c a 30 A ou plus Sch ma 8 Sch ma 8 Prise 120 240 V c a 30 A 120V 240V 30A Utiliser cette prise pour faire fonctionner les charges monophas es de 120 V c a 60 Hz n cessitant 3 600 watts 3 6 kW d alimentation 30 A ou des charges monophas es de 240 V c a 60 Hz n cessitant 7 200 watts 7 2 kW d alimentation 30 A La prise est prot g e par deux disjoncteurs de type pousser pour r enclencher de 30 A 2 4 UTILISATION DU GENERATEUR Si des probl mes se pr sentent lors du fonctionnement du g n rateur merci d appeler la ligne d assistance pour les g n rateurs au 1 888 436 3722 DANGER 4 DANGER 4 PELIGRO Using a generator indoors CAN KILL Utiliser un g n rateur l int rieur PEUT Si usa un generador en interiores YOU IN MINUTES VOUS TUER EN QUELQUES MINUTES MORIR EN POCOS MINUTOS Generator exhaust contains carbon Les gaz d chappement du g n rateur El escape del generador contiene monoxide This is a poison you contiennent du monoxyde de carbone mon xido de carbono Es un veneno cannot see or smell C est un gaz toxique invisible et i
43. proc dure et se trouvent dans le corps de texte r gulier de ce manuel Ces avertissements de s curit ne peuvent pas liminer les dangers qu ils signalent Le sens commun et le respect strict des instructions sp ciales lors de l entretien sont essentiels pour viter les accidents Quatre symboles de s curit couramment utilis s accompagnent les blocs DANGER AVERTISSEMENT et ATTENTION Chacun indique le type d informations suivant Ce symbole indique des informations importantes relatives la s curit qui si elles ne sont pas suivies pourraient mettre en danger la s curit personnelle et ou les biens des autres AA Ce symbole indique un risque potentiel d explosion A Ce symbole indique un risque potentiel d incendie Ce symbole indique un risque potentiel d lectrocution DANGERS G N RAUX Ne jamais faire fonctionner dans un espace clos ou l int rieur Pour des raisons de s curit le fabricant recommande que la maintenance de cet quipement soit effectu e par un d positaire agr Inspecter r guli rement le g n rateur et contacter le d positaire agr le plus proche pour les pi ces qui n cessitent une r paration ou un remplacement Faire fonctionner le g n rateur uniquement sur des surfaces de niveau et o il ne sera pas expos l humidit aux salet s la poussi re ou aux vapeurs corrosives excessives Tenir les mains les pieds les v tements etc distance
44. required Engine All Components Alternator All Components NOTE For the purpose of this warranty consumer use means personal residential household or recreational use by original purchaser This warranty does not apply to units used for Prime Power in place of utility where utility power service is present or where utility power service does not normally exist Once a generator has experienced commercial or rental use it shall thereafter be considered a non consumer use generator for the purpose of this warranty All warranty expense allowances are subject to the conditions defined in Generac s Warranty Policies Procedures and Flat Rate Manual THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING Generac built portable generators built prior to May 2008 Generac portable generators that utilize non Generac replacement parts Costs of normal maintenance and adjustments Failures caused by any contaminated fuels oils or lack of proper oil levels Repairs or diagnostics performed by individuals other than Guardian Generac authorized dealers not authorized in writing by Generac Power Systems Failures due but not limited to normal wear and tear accident misuse abuse negligence or improper use As with all mechanical devices the Generac engines need periodic part s service and replacement to perform as designed This warranty will not cover repair when normal use has exhausted the life of a part s or engine Failure
45. une m thode de travail ou une technique de fonctionnement que le fabricant ne recommande pas en particulier assurez vous qu elle est sans danger pour les autres S assurer que la proc dure la m thode de travail ou la technique de fonctionnement choisie ne rende pas le g n rateur dangereux LES INFORMATIONS CONTENUES DANS LE PRESENT MANUEL SE BASENT SUR LES MACHINES EN PRODUCTION AU MOMENT DE LA PUBLICATION GENERAC SE RESERVE LE DROIT DE MODIFIER CE MANUEL TOUT MOMENT R GLES DE S CURIT Dans tout ce manuel et sur les tiquettes et sur les autocollants appos s sur le g n rateur les blocs DANGER AVERTISSEMENT ATTENTION et REMARQUE servent alerter le personnel d instructions sp ciales au sujet d une op ration sp cifique qui peut s av rer dangereuse si elle n est pas effectu e correctement ou avec pr caution Les respecter attentivement Leurs d finitions sont les suivantes DANGER INDIQUE UNE SITUATION OU UNE ACTION DANGEREUSE QUI SI ELLE N EST PAS EVITEE ENTRAINERA LA MORT OU DES BLESSURES GRAVES AVERTISSEMENT Indique une situation ou une action dangereuse qui si elle n est pas vit e entra nera la mort ou des blessures graves ATTENTION Indique une situation ou une action dangereuse qui si elle n est pas vit e entra nera des blessures l g res ou mod r es REMARQUE Les remarques contiennent des informations suppl mentaires importantes relatives une
46. v D 07 01 10 Imprim aux Etats Unis
47. va a conectar al mismo tiempo Este total NO debe ser mayor que la capacidad de potencia nominal del generador La potencia nominal de las luces puede encontrarse en las bombillas La potencia nominal de las herramientas electrodom sticos y motores generalmente puede encontrarse en una etiqueta de informaci n o en una calcoman a fijada al dispositivo Si el electrodom stico herramienta o motor no especifica el vataje multiplique los voltios por los amperios para determinar los vatios voltios x amperios vatios Algunos motores el ctricos tales como los del tipo de inducci n requieren cerca de tres veces m s vatios de potencia para arrancar que para funcionar Este incremento s bito de electricidad dura s lo unos segundos cuando arranca tales motores Cerci rese de tomar en cuenta este alto vataje de arranque cuando elija los dispositivos el ctricos que va a conectar al generador 1 Calcule los vatios necesarios para arrancar el motor de mayor tama o 2 Sume a ese n mero los vatios en consumo de todas las otras cargas conectadas FUNCIONAMIENTO La Gu a de referencia de vataje le ayuda a determinar cu ntos art culos equipos pueden funcionar con el generador al mismo tiempo NotA Todas las cifras son aproximadas Refi rase a la etiqueta de informaci n en el electrodom stico para los requerimientos de vataje 2 6 GU A DE REFERENCIA DEL VATAJE Secci n 2 Funcionamiento Sistema de generador po
48. ventilation tant donn que cela peut s rieusement affecter le fonctionnement s r du g n rateur Il FAUT faire fonctionner le g n rateur l ext rieur Ce syst me d chappement doit tre correctement entretenu Ne rien faire qui pourrait rendre le syst me d chappement dangereux ou non conforme aux codes locaux et ou normes locales Le fabricant recommande d installer un d tecteur d oxyde de carbone alimentation par batterie l int rieur conform ment aux instructions du fabricant DANGERS LECTRIQUES Le g n rateur produit une tension dangereusement haute pendant son fonctionnement Eviter le contact avec les fils nus les bornes les branchements etc pendant le fonctionnement de l unit m me sur l quipement branch au g n rateur S assurer que tous les couvercles les dispositifs de protection et les barri res sont en place avant de faire fonctionner le g n rateur Ne jamais manipuler tout type de cordon ou de dispositif lectrique qui est dans l eau alors que vous tes pieds nus ou que vos mains ou vos pieds sont mouill s Cela entra nera un risque d lectrocution 40 Le National Electric Code Code lectrique national exige que le b ti et que les pi ces externes lectriquement conductrices du g n rateur soient correctement reli s une terre approuv e Les codes lectriques locaux peuvent galement exiger la bonne mise la terre du g n rateur Consulter un lectricien local
49. 13 Choke Position IMPORTANT Do not overload the generator Also do not overload individual panel receptacles These outlets are protected against overload with push to reset type circuit breakers If amperage rating of any circuit breaker is exceeded that breaker opens and electrical output to that receptacle is lost Read Don t Overload the Generator carefully 2 9 STARTING ELECTRIC START ENGINES WARNING amp Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on Unplug all electrical loads from the unit s receptacles before starting the engine Make sure the unit is in a level position Open the fuel shut off valve Figures 12 and 14 Move engine CHOKE knob outward to Full Choke position Figure 15 Figure 14 Fuel Shut off Valve LA f OFF 7 ON FUEL SHUTOFF To start engine press and hold the Start Run Stop switch in the Start position The engine will crank and attempt to start When the engine starts release the switch to the run position When the engine starts move choke knob to 1 2 Choke position until the engine runs smoothly and then fully in to the Run position If engine falters move choke knob back out to 1 2 Choke position until the engine runs smoothly and then to Run position 9 OPERATION Section 2 Operation dE Portable Generator System This gener
50. 3 3 7 REEMPLAZO DE LA BATER A NOTA La bater a inclu da en el generador ha sido cargada completamente Una bater a puede perder algo de su carga cuando no se le usa por tiempo prolongado Si la bater a es incapaz de arrancar el motor conecte el cargador de 12 voltios incluido en la caja de accesorios ver la secci n Cargando una bater a EL HACER FUNCIONAR EL GENERADOR NO CARGA LA BATER A precauci n El terminal NEGATIVO de la bater a debe 1 DESCONECTARSE PRIMERO siempre 2 CONECTARSE DE LTIMO siempre Figura 18 Conexiones de la bater a NEGRO TUERCA ARANDELA DE SEGURIDAD ARANDELA PLANA CABLE NEGATIVO DE 4 LA BATER A NEGRO FUNDA DEL CABLE CABLE POSITIVO DE LA BATER A ROJO TORNILLO 3 4 SERVICIO DEL FILTRO DE AIRE El motor no trabajar adecuadamente y puede da arse si se utiliza un limpiador de aire que est sucio Limpie o cambie el filtro de aire de papel una vez al a o Figura 19 Limpie o cambie m s a menudo su trabaja en ambiente polvoriento Figura 19 Limpiador de aire Para limpiar o cambiar el filtro de aire de papel Retire la cubierta del limpiador de aire y quite el filtro de papel Limpie el filtro de papel golpe ndolo suavemente sobre una superficie s lida Si el filtro est demasiado sucio c mbielo por uno nuevo Deseche el filtro adecuadamente Limpie la cubierta del limpiador de aire luego inserte un nuevo f
51. A vacuum cleaner may be used to pick up loose dirt and debris Low pressure air not to exceed 25 psi may be used to blow away dirt Inspect cooling air slots and openings on the generator These openings must be kept clean and unobstructed 11 MAINTENANCE 20 Section 3 Maintenance Portable Generator System 3 3 3 ENGINE MAINTENANCE DIT A When working on the generator always disconnect negative cable from battery Also disconnect spark plug wire from spark plug and keep wire away from spark plug 3 3 4 CHECKING OIL LEVEL See the Before Starting the Generator section for information on checking the oil level The oil level should be checked before each use or at least every eight hours of operation Keep the oil level maintained 3 3 5 CHANGING THE OIL Change the oil after the first 30 hours of operation Change the oil every 100 hours or every season thereafter If running this unit under dirty or dusty conditions or in extremely hot weather change the oil more often caution amp Hot oil may cause burns Allow engine to cool before draining oil Avoid prolonged or repeated skin exposure with used oil Thoroughly wash exposed areas with soap Use the following instructions to change the oil while the engine is still warm Clean area around oil drain plug Remove oil drain plug from engine and oil fill plug to drain oil completely into a suitable container e When oil has co
52. ALIFORNIA El Estado de California sabe que el escape del motor y algunos de sus componentes causan cancer defectos de nacimiento y otros da os reproductivos ADVERTENCIA DE LA PROPOSICI N 65 DE CALIFORNIA Este producto contiene o emite qu micos que el Estado de California sabe que causan c ncer defectos de nacimiento u otros da os reproductivos 23 Secci n 1 Informaci n general Sistema de generador port til INFORMACI N GENERAL 1 1 C MO DESEMPACAR Retire todos los materiales de embalaje Retire la caja de accesorios que viene separada Retire el generador de la caja 1 1 1 CAJA DE ACCESORIOS Revise todo el contenido Si faltan partes o est n da adas ubique un distribuidor autorizado llamando al 1 888 436 3722 El contenido incluye e 1 Manual del propietario 1 Ensamble de manija izquierda 2 Ruedas macizas 1 Ensamble de manija derecha e 1 Soporte de la pata e 1 Pata de la estructura e 1 Cuarto de gal n 0 9 1 de aceite SAE 30 1 Cargador con adaptador para 12 voltios e 1 Bolsa de herrajes contiene lo siguiente 2 Patas de goma 2 Pernos de 545 2 Arandelas planas de 546 2 Pernos del eje de 7 2 Arandelas planas de Y 4 Pernos cabeza de hongo de 546 4 Tuercas de bloqueo 54 c brida 2 Tuercas de bloqueo Y c brida 2 Tuercas de bloqueo con capuch n de 546 Unidades de arranque el ctrico nicamente 1 2 ENSAMBLAJE El generador requiere cie
53. C MO AJUSTAR LA ABERTURA DE LA VALVULA Despu s de las primeras 50 horas de funcionamiento revise la abertura de la v lvula en el motor y ajuste si fuese necesario Importante Si no se siente preparado para ejecutar este procedimiento o si no tiene las herramientas adecuadas para hacerlo lleve el generador al centro de servicio m s cercano para ajustar la abertura de la v lvula Este es un paso muy importante para prolongar la vida del motor Para revisar la abertura de la v lvula Cerci rese de que el motor est a temperatura ambiente 60 80 F 16 27 Cerci rese de que el cable de la buj a se haya retirado de la buj a y no interfiera Retire la buj a Retire los cuatro tornillos que fijan la cubierta de la v lvula Cerci rese de que el pist n est en el punto muerto superior PMS de su recorrido de compresi n ambas v lvulas cerradas Para llevar el pist n al PMS retire la pantalla de toma al frente del motor para obtener acceso a la tuerca de volante Utilice una dado grande y una llave de tubo para rotar la tuerca y por consiguiente el motor en el sentido horario mientras observa el pist n a trav s del agujero de la buj a El pist n debe moverse hacia arriba y hacia abajo El pist n est en PMS cuando est hacia arriba tanto como pueda recorrer Inserte una l mina calibradora de 0 002 0 004 0 05 0 1mm entre el balanc n y el v stago de la v lvula La abertura correcta es cuan
54. CI N COMERCIAL ALQUILER DURANTE UN ANO 100 cien por ciento cobertura en mano de obra y pieza s indicada s se requiere prueba de compra y de mantenimiento Motor Todos los componentes Alternador Todos los componentes NOTA A los fines de esta garant a uso del consumidor significa el uso personal residencial dom stico o de recreaci n por parte del comprador original Esta garant a no aplica a unidades que se utilicen como fuente primaria de energ a en lugar de los servicios p blicos donde estos est n presentes o donde el servicio p blico no exista normalmente Una vez que el generador haya estado sujeto a uso comercial o de alquiler se considerar en lo sucesivo como un generador de uso no personal para los fines de esta garant a Todos los gastos relacionados con la garant a est n sujetos a las condiciones definidas en las Pol ticas y Procedimientos de Garant a y el Manual de Flete Plano de Generac ESTA GARANTIA NO APLICA A LO SIGUIENTE Generadores port tiles fabricados por Generac antes de mayo 2008 Costos de mantenimiento y ajustes normales Fallas causadas por combustibles aceites contaminados o la falta de niveles adecuados de aceite Reparaciones o diagn sticos efectuados por personas distintas de los distribuidores autorizados Guardian Generac que no est n autorizados por escrito por parte de Generac Power Systems Fallas debidas al desgaste por uso normal accidente uso inadecuado abuso negli
55. DE L HUILE DE MOTEUR Toute huile doit respecter la cat gorie de service minimale SJ SL ou mieux de l American Petroleum Institute API Institut am ricain du p trole Nutiliser aucun additif sp cial S lectionner le degr de viscosit d huile selon la temp rature d exploitation se reporter galement au tableau e Au dessus de 40 F utiliser le SAE 30 En dessous de 40 F et jusqu 10 F utiliser le 10W 30 En dessous de 10 F utiliser le 5W 30 synth tique 10W 30 XT x 5W 30 synth tique F 20 10 0 10 20 32 40 60 80 100 C 30 20 10 0 10 20 30 40 Plage de temp ratures de l utilisation pr vue ATTENTION Toute tentative de faire tourner ou de d marrer le moteur avant qu il ait t correctement entretenu avec l huile recommand e peut entra ner une panne du moteur Installer le g n rateur sur une surface de niveau Nettoyer l espace autour de l orifice de remplissage d huile et retirer le bouchon e Remplir lentement le moteur avec de l huile jusqu ce qu elle atteigne les filets de l orifice de remplissage d huile voir Sch ma 10 Interrompre r guli rement le remplissage pour v rifier le niveau d huile Mettre le bouchon sur l orifice de remplissage de l huile et le serrer fermement au doigt V rifier le niveau d huile de moteur avant le d marrage chaque fois par la suite 46 Sch ma 10 Niveau d huil
56. Dehumidifier 650 Disc Sander 9 ze te 1200 Edge Trimmer ooo iia 500 Electric Blanket 22 sies e eere 400 Electric Nail Gil ror errem gu 1200 Electric Range per element 1500 10 700 Furnace Fan 3 5 875 Garage Door Opener 500 to 750 Cm 1200 i oth aae ta 250 to 1100 Hedge IMIMIMEN ho ce utes 450 IMPACT WIENCN c csse m DU 500 A E ON 1200 USE PHITID 800 00 22 ers aie Passo 1200 Light 0 2 100 Microwave 700 to 1000 Milk Co0lar seen ai va res 1100 Oil Burner on Furnace 300 Oil Fired Space Heater 140 000 Btu 400 Oil Fired Space Heater 85 000 Btu 225 Oil Fired Space Heater 30 000 Btu 150 Paint Sprayer Airless 1 3 600 Paint Sprayer Airless handheld 150 etit edax esas 50 to 200 Refrigera 0 s rr 700 Slow Cooker 200 OPERATION Section 2 Operation dE Portable Generator System Submersible Pump 1 1 2 HP 2800 Submers
57. ERADOR Utilice un pa o h medo para limpiar las superficies externas Puede utilizar una brocha de cerdas suaves para aflojar el sucio o aceite incrustado etc Puede utilizar una aspiradora para recoger el sucio y los desechos sueltos Puede utilizar aire de baja presi n que no exceda de 25 psi para retirar el sucio Inspeccione las ranuras y aberturas de ventilaci n del generador que deber n mantenerse limpias y sin obstrucciones 3 9 3 MANTENIMIENTO DEL MOTOR 109 A Cuando se trabaja en el generador siempre se debe desconectar el cable negativo de la bater a Tambi n desconecte el cable de la buj a y mant ngalo lejos de esta 31 MANTENIMIENTO 20 Secci n 3 Mantenimiento Sistema de generador port til 3 3 4 REVISI N DEL NIVEL DE ACEITE Refi rase a la secci n Antes de arrancar el generador para informaci n sobre la revisi n del nivel de aceite Deber revisar el nivel de aceite antes de cada uso 0 al menos cada ocho horas de funcionamiento Conserve el nivel de aceite adecuado 3 3 5 CAMBIO DE ACEITE Cambie el aceite luego de las primeras 30 horas de operaci n Cambie el aceite cada 100 horas o cada cambio de estaci n luego de ello Si est haciendo funcionar la unidad en condiciones de polvo o suciedad o en clima extremadamente c lido cambie el aceite con m s frecuencia precauci n El aceite caliente puede causar quemaduras Deje que
58. Emplacement de remplissage d huile Jauge de carburant Indique le niveau de carburant dans le r servoir Remplissage d huile Ajouter de l huile ici Lanceur rappel Utiliser pour d marrer le moteur manuellement Soupape d arr t Soupape entre le r servoir d essence et le carburateur Vidange d huile Utilis pour vidanger l huile de moteur 18 Entr e du chargeur de la batterie Cette prise a la capacit de recharger la batterie rechargeable c c de 12 volts quip e d un chargeur d adaptateur de 12 volts qui est inclus dans la boite d accessoires Derri re l entr e du chargeur de la batterie il y a un fusible en ligne de 1 50 A qui se trouve l int rieur du panneau de commande afin de prot ger la batterie 19 Batterie Met sous tension le d marreur lectrique D marrage lectrique uniquement Sch ma 5 Commandes du g n rateur D TAIL A 43 FONCTIONNEMENT Section 2 Fonctionnement sez G n rateur portable 2 2 HOROMETRE L horom tre rel ve les heures de fonctionnement pour la maintenance programm e Un message CHG OIL s affichera toutes les 100 heures Le message clignotera une heure avant et une heure apr s chaque intervalle de 100 heures laissant nouveau une marge de deux heures pour effectuer l entretien Ce message commencera a clignoter la 99 me heure et se d sactivera a la 101 me heure laissant une marge de deux h
59. GP Series 7 000 amp 8 000 Watt Portable Generator COMMERCIAL INDUSTRIAL RESIDENTIAL MODELS 005625 0 005626 0 Owner S 005680 0 005681 0 Manual e SAFETY e ASSEMBLY e OPERATION e TROUBLESHOOTING e WARRANTY 2 YEAR LIMITED WARRANTY AUTHORIZED DEALER SUPPORT E E R AC AS 1 888 436 3722 TABLE Table of Contents OF Portable Generator System CONTENTS o AA oe 1 Read this Manual Thoroughly 1 Safety A A 2 Standards Index vic ici da 3 Section 1 General Information 4 1 1 UMPACKING 0 4 1 1 1 Accessory 4 1 2 4 1 2 1 Assembling the Accessory Kit 4 1 2 2 Starter Connection Electric Start Only 4 Section 2 5 2 1 Know the Generator e sesseessrsesrrenrrrsrrsrsrrsrsssessesess 5 2 2 E 6 2 3 Sets and Connection Plugs 6 2 3 1 120 VAC 20 Amp Duplex Receptacle 6 2 3 2 120 240 VAC 30 Amp Receptacle 6 2 4 How to Use the 6 2 4 1 Grounding the 6 2 4 2 Connecting Electrical Loads 7 2 5 Don t
60. IRE ATTENTIVEMENT CE MANUEL En cas d incompr hension d une partie de ce manuel contacter le d positaire agr le plus proche pour connaitre les proc dures de d marrage de fonctionnement et d entretien L op rateur est responsable de l utilisation correcte et s re de l quipement Nous recommandons fortement l op rateur de lire ce manuel et de comprendre compl tement toutes les instructions avant d utiliser l quipement Nous recommandons galement fortement d apprendre d autres utilisateurs comment correctement d marrer et faire fonctionner l unit Cela les pr pare au cas o ils auraient besoin de faire fonctionner l quipement pour une urgence Le g n rateur peut fonctionner en toute s curit de fa on efficace et de fa on fiable uniquement s il est correctement install utilis et entretenu Avant de faire fonctionner ou d effectuer l entretien du g n rateur Se familiariser avec et respecter strictement tous les codes et r glementations locaux d tat et nationaux Lire attentivement tous les avertissements de s curit figurant dans ce manuel et sur le produit e Se familiariser avec ce manuel et l unit avant de l utiliser Le fabricant ne peut pas anticiper toutes les situations possibles qui peuvent impliquer un danger Les avertissements de ce manuel et figurant sur les tiquettes et les autocollants appos s sur l unit ne sont toutefois pas exhaustifs Si vous suivez une proc dure
61. Les frais de transport de nuit ou d envoi sp cial de la ou des pi ce s de rechange Les heures suppl mentaires le travail de jour f ri ou en urgence de la main d uvre Les batteries de d marrage fusibles ampoules et fluides du moteur LA PR SENTE GARANTIE REMPLACE TOUTES LES AUTRES GARANTIES IMPLICITES OU EXPLICITES EN PARTICULIER GENERAC N MET AUCUNE GARANTIE DE CONFORMIT OU D USAGE POUR UN OBJECTIF PARTICULIER Certains tats ne permettent pas de poser une limite la dur e de la garantie implicite la limite susmentionn e ne s applique donc pas ces derniers GENERAC NE SERA RESPONSABLE QUE DE LA REPARATION OU DU REMPLACMEENT DE LA OU DES PIECES TEL QUE SUSMENTIONNE EN AUCUN CAS GENERAC NE POURRA ETRE TENU RESPONSABLE DE TOUT DOMMAGE ACCESSOIRE OU IMPORTANT MEME SI CE DOMMAGE DECOULE DIRECTEMENT D UNE NEGLIGENCE DE GENERAC Certains tats ne permettent pas d exclure ou de poser une limite aux dommages accessoires ou importants la limite susmentionn e ne s applique donc pas a ces derniers La pr sente garantie vous conf re des droits juridiques sp cifiques Votre tat vous conf re galement d autres droits GENERAC POWER SYSTEMS INC PO 8 Waukesha WI 53187 T l 888 GENERAC 436 3722 Fax 262 544 4851 Pour localiser le d positaire le plus proche visitez notre site Internet www generac com R f rence 069451 R vision D 27 10 08 Imprim aux tats Unis Manuel r f rence 008751 R
62. OSITIF du d marreur du moteur OU le c ble de batterie N GATIF de la borne de la batterie ce qui est le plus facile avant de transporter le g n rateur REMARQUE Ce g n rateur est quip d un silencieux pare tincelles Le propri taire l op rateur du g n rateur devra garder le pare tincelles en bon tat Dans l tat de Californie un pare tincelles est exig par la loi Section 4442 du California Public Resources Code Code de ressources publiques de Californie Les autres Etats peuvent avoir des lois similaires Les lois f d rales s appliquent sur les terres f d rales 39 REGLES DE S CURIT G n rateur portable CONSIGNES DE S CURIT IMPORTANTES CONSERVER CES CONSIGNES Le fabricant recommande que ces r gles relatives au fonctionnement s r soient copi es et affich es a proximit du site d installation de l unit Tous les op rateurs et op rateurs potentiels de cet quipement doivent prendre conscience de la question de la s curit ECHAPPEMENT ET LE DANGER D EMPLACEMENT DANGER NE JAMAIS faire fonctionner le g n rateur l int rieur NE JAMAIS utiliser l int rieur d une maison ou d un garage MEME SI les portes et les fen tres sont ouvertes Utiliser UNIQUEMENT l ext rieur et loin des fen tres portes ouvertes ventilations et dans un espace dans lequel le gaz d chappement ne s accumulera pas de fa on mortelle DANGER DANGER PELIGRO
63. Overload the 7 2 6 Wattage Reference Guide 7 2 7 Before Starting the 8 2 7 1 Adding Engine Oil u u uu uuu 8 2 7 2 Adding Gasoline sees 8 2 8 Starting Pull Start 9 2 9 Starting Electric Start 9 2 10 Stopping the Engine e 10 2 11 Low Oil Level Shutdown System 10 2 10 1 Sensing Low Oil Level 10 2 12 Charging a Battery Electric Start Units Only 10 Section 3 Maintenance 11 3 1 Maintenance 11 3 2 Product Specifications 11 3 2 1 Generator 11 3 2 2 Engine 11 3 3 General 11 3 3 1 Generator 11 3 3 2 Clean the 11 3 3 3 Engine 12 3 3 4 Checking Oil Level
64. R Read the Owner s Manual and Safety Rules before operating this generator Compare the generator to Figures 4 through 6 to become familiarized with the locations of various controls and adjustments Save this manual for future reference 1 go m o 9 10 120 Volt AC 20 Amp Duplex Receptacle Supplies electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads 120 240 Volt AC 30 Amp Locking Receptacle Supplies electrical power for the operation of 120 and or 240 Volt 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Circuit Breakers AC Each receptacle is provided with a push to reset circuit breaker to protect the generator against electrical overload Figure 4 Control Panel Hourmeter Tracks hours of operation Air Filter Filters intake air as it is drawn into the engine Choke Knob Used when starting a cold engine Fuel Tank Tank holds 6 6 U S gallons of fuel Grounding Lug Ground the generator to an approved earth ground here See Grounding the Generator for details Run Stop Switch Controls the operation of the generator Muffler Quiets the engine OPERATION OD Section 2 Operation Portable Generator System Handles Pivot and retract for storage Press the spring loaded button to move handles Gas Cap Fu
65. Y LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART S AS STATED ABOVE IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC S NEGLIGENCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights You also have other rights from State to state GENERAC POWER SYSTEMS INC PO BOX 8 Waukesha WI 53187 Ph 888 GENERAC 436 3722 Fax 262 544 4851 To locate the nearest Authorized Dealer visit our website www generac com Part No 069451 Revision D 10 27 08 Printed in U S A Manual Part No 0G8751 Rev D 01 07 10 Printed in U S A Serie GP Generador port til de 7 000 y 8 000 vatios COMERCIAL INDUSTRIAL RESIDENCIAL Manual del MODELOS 005625 0 005626 0 005680 0 005681 0 propietario e SEGURIDAD ENSAMBLAJE FUNCIONAMIENTO SOLUCI N DE PROBLEMAS GARANT A E ASISTENCIA T CNICA DEL DISTRIBUIDOR AUTORIZADO Pici E G E N RAC 1 888 436 3722 ndice NDICE Sistema de generador port til II ua assasi sasawa Lea este manual atentamente Reglas de seguridad ndice de Secci n 1 Informaci n general
66. a por los elementos y per odo establecidos en este documento Generac a su discreci n reparar o reemplazar cualquier parte que luego de ser sometida a examen inspecci n y prueba por parte de Generac o de un distribuidor de servicio autorizado en garant a de Generac se encuentre defectuosa Cualquier equipo que el comprador propietario considere defectuoso deber devolverlo para que sea examinado por el distribuidor de servicio autorizado en garant a de Generac Todos los costos de transporte bajo esta garant a incluyendo el de devoluci n a la f brica deben ser costeados y prepagados por el comprador propietario Esta garant a aplica nicamente a los generadores port tiles de la serie GP de Generac y no es transferible con respecto al comprador original Guarde su recibo de prueba de compra Si no proporciona prueba de la fecha de compra inicial la fecha de env o del fabricante del producto se utilizar para determinar el per odo de garant a PROGRAMACI N DE LA GARANT A Las aplicaciones de los consumidores est n garantizadas por dos 2 a os Las aplicaciones comerciales o de alquiler est n garantizadas por un 1 a o o un m ximo de 1 000 horas lo que ocurra primero APLICACI N DEL CONSUMIDOR PRIMER y SEGUNDO A O 100 cien por ciento cobertura en mano de obra y pieza s indicada s se requiere prueba de compra y de mantenimiento Motor Todos los componentes Alternador Todos los componentes APLICA
67. a slight drag is felt when sliding the gauge back and forth If the clearance is either excessively loose or tight the rocker arms will need adjusting To adjust valve clearance Loosen the rocker jam nut Figure 21 Use an 10mm allen wrench to turn the pivot ball stud while checking clearance between the rocker arm and the valve stem with a feeler gauge Correct clearance is 0 002 0 004 inch 0 05 0 1 mm 13 MAINTENANCE 20 Section 3 Maintenance Figure 21 Valve Clearance Adjustment Pivot Ball Jam Nut NOTE The rocker arm jam nut must be held in place as the pivot ball stud is turned When valve clearance is correct hold the pivot ball stud in place with the allen wrench and tighten the rocker arm jam nut Tighten the jam nut to 174 in lbs torque After tightening the jam nut recheck valve clearance to make sure it did not change Install new valve cover gasket Re attach the valve cover NOTE Start all four screws before tightening or it will not be possible to get all the screws in place Make sure the valve cover gasket is in place Replace spark plug Re attach the spark plug wire to the spark plug 3 7 LONG TERM STORAGE It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor fuel hose or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads
68. ag e dans un centre de collecte appropri 3 3 6 REMPLACEMENT DES BOUGIES D ALLUMAGE Utiliser des bougies d allumage Champion RC14YC ou quivalent Remplacer les bougies une fois par an Cela permettra un d marrage plus facile et un meilleur fonctionnement du moteur 1 Arr ter le moteur et d brancher le fil de bougie de la bougie d allumage 2 Nettoyer la zone autour de la bougie d allumage et la retirer de la culasse 3 R gler l cartement de bougie d allumage 0 70 0 80 mm 0 028 0 031 po Installer la bougie d allumage correctement cart e dans la culasse Sch ma 17 G n rateur portable Sch ma 17 cartement de la bougie d allumage 50 Section 3 Maintenance 3 3 7 REMPLACEMENT DE LA BATTERIE REMARQUE La batterie envoy e avec le g n rateur a t compl tement charg e Une batterie peut perdre une partie de sa charge lorsqu elle n est pas utilis e pendant des p riodes prolong es S il est impossible de d marrer le moteur l aide de la batterie brancher le chargeur de 12 V inclus dans la bo te d accessoires voir la section Chargement de la batterie FAIRE FONCTIONNER LE GENERATEUR NE CHARGE PAS LA BATTERIE ATTENTION La borne N GATIVE de la batterie doit 1 Toujours tre DEBRANCHEE EN PREMIER 2 Toujours tre BRANCHEE EN DERNIER Sch ma 18 Branchements de la batterie NOIR CROU C BLE N GATIF DE LA BATTERIE NOIR C BLE
69. ales combustibles sobre o cerca del generador Mantenga el rea circundante del generador limpia y libre de residuos y conserve un espacio de cinco 5 pies a todos los lados para permitir una ventilaci n apropiada del generador No opere el generador si los dispositivos el ctricos conectados se sobrecalientan si la salida el ctrica se pierde si el motor o el generador echan chispas o si se observa humo cuando la unidad est funcionando Tenga un extinguidor cerca al generador en todo momento INSTRUCCIONES IMPORTANTES SOBRE SEGURIDAD REGLAS DE SEGURIDAD NDICE DE EST NDARES En ausencia de los est ndares c digos regulaciones o leyes pertinentes la informaci n publicada listada abajo puede usarse como gu a para la operaci n de este equipo Siempre consulte la revisi n m s reciente aplicable para el estandar listado 1 NFPA No 70 NFPA HANDBOOK OF NATIONAL ELECTRIC CODE 2 Article X NATIONAL BUILDING CODE disponible en la American Insurance Association 85 John Street New York 10038 3 AGRICULTURAL WIRING HANDBOOK disponible en la Food and Energy Council 909 University Avenue Columbia MO 65201 4 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS disponible en la American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 5 NFPA No 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE Sistema de generador port til AN ADVERTENCIA DE LA PROPOSICION 65 DE C
70. ant les 2 trous e Faire glisser les boulons de 0 31 po installer les crous borgnes de 0 31 po Sch ma 1 Montage de la roue 2 X CONTRE CROUS 1 2 J 2X BOULON 5 16 2X ROUE 2XRONDELLE 2 X RONDELLE PLATE 1 PLATE 5 16 2X BOULON D ESSIEU PIED SUPPORT DU PIED 4X ECROUS Mog MBASE 5 16 2 X PARECHOCS EN CAOUTCHOUC Sch ma 2 Installation de la poign e RETIRER JETER LE BOULON T TE COURB E RETIRER ET R UTILISER L ECROU BORGNE CROU BORGNE CHELLE 0 200 1 2 2 BRANCHEMENT DU D MARREUR D MARRAGE ELECTRIQUE UNIQUEMENT L unit a t envoy e avec le c ble de d marreur d branch Pour brancher le d marreur 1 Localiser le c ble de d marreur une tiquette fil est attach e comme indiqu sur le Sch ma 3 2 Rabattre la protection en vinyle sur le c ble de d marreur 3 Retirer l crou et la rondelle du montant du d marreur 4 Placer le c ble de d marreur sur le montant et remettre la rondelle et l crou Sch ma 3 Branchement du d marreur 2 1 BIEN CONNA TRE LE G N RATEUR Merci de lire le Manuel d entretien et les R gles de s curit avant de faire fonctionner ce g n rateur Comparer le g n rateur aux Sch mas 4 6 pour vous familiariser avec les emplacements des divers contr les et r glages Conserver ce manuel pour m moire 1 Prise double DDFT 120
71. arrosage pour nettoyer le g n rateur L eau peut entrer dans le syst me de carburant du moteur et causer des probl mes En outre si l eau entre dans le g n rateur par les fentes de refroidissement de l eau restera dans les vides et les crevasses du bobinage d isolement du rotor et du stator L accumulation d eau et de salet s sur les bobinages internes du g n rateur diminuera potentiellement la r sistance d isolement de ces bobinages 3 3 2 NETTOYAGE DU G N RATEUR Utiliser un chiffon humide pour le nettoyage des surfaces externes est possible d utilise une brosse douce en poils pour d coller les agglutinements de salet s d huile etc e Un aspirateur pourra tre utilis pour r cup rer les salet s et les d bris Un air projet avec une faible pression inf rieur 25 livres par pouce carr pourra tre utilis pour souffler la salet Inspecter les fentes de refroidissement et les orifices du g n rateur Ces orifices doivent tre propres et non obstru s 3 3 3 MAINTENANCE DU MOTEUR A DEG Toujours d brancher le c ble n gatif de la batterie en cas de travail sur le g n rateur Toujours d brancher les fils de bougie des bougies d allumage et les tenir loign s de celles ci Section 3 Maintenance G n rateur portable 49 MAINTENANCE 2D 3 3 4 V RIFICATION DU NIVEAU D HUILE Se reporter a la section Avant le d marrage du g n rateur pour plus d informatio
72. articulation Culbuteur crou de blocage REMARQUE L crou de blocage du culbuteur doit rester en place pendant que l on fait tourner l axe de l articulation rotule 51 MAINTENANCE 2D Section 3 Maintenance G n rateur portable Lorsque le jeu des soupapes est correct maintenir l axe de l articulation rotule en place l aide de la cl hexagonale et resserrer l crou de blocage du culbuteur Serrer l crou de blocage un couple de 174 pouces livres Apr s avoir resserr l crou de blocage rev rifier le jeu des soupapes pour s assurer qu il n a pas chang Installer le nouveau joint de couvercle de soupape Replacer le couvercle de soupape REMARQUE Commencer visser les quatre vis avant de les resserrer toutes sinon il sera impossible de mettre toutes les vis S assurer que le joint du couvercle de soupape est en place Remplacer la bougie d allumage Rebrancher le fil de bougie la bougie d allumage 3 7 STOCKAGE LONG TERME Pendant le stockage il est important d emp cher la formation de d p ts de gomme dans les pi ces essentielles du circuit de carburant telles que le carburateur le tuyau pour combustible ou le r servoir L exp rience montre galement que les carburants base d alcool appel s gazohol thanol ou m thanol peuvent absorber l humidit ce qui entra ne une s paration et la formation d acides pendant le stockage Un gaz acide peut endommager le
73. ator is also equipped with a manual recoil starter which may be used if the battery is discharged NOTE The switch must be in the RUN position start manually firmly grasp the recoil handle and pull slowly until increased resistance is felt Pull rapidly up and away to start engine Then follow the same choke sequence NOTE If engine fires but does not continue to run move choke lever to Full Choke and repeat starting instructions Figure 15 Choke Position IMPORTANT Do not overload the generator Also do not overload individual panel receptacles These outlets are protected against overload with push to reset type circuit breakers If amperage rating of any circuit breaker is exceeded that breaker opens and electrical output to that receptacle is lost Read Don t Overload the Generator carefully 2 10 STOPPING THE ENGINE Shut off all loads then unplug the electrical loads from generator panel receptacles Never start or stop the engine with electrical devices plugged in and turned on Let engine run at no load for several minutes to stabilize the internal temperatures of engine and generator Move Run Stop switch to OFF position Close fuel valve 2 11 LOW OIL LEVEL SHUTDOWN SYSTEM The engine is equipped with a low oil level sensor that shuts down the engine automatically when the oil level drops below a specified level If the engine shuts down by itself and the fuel tank has enough
74. caciones en la Programaci n de mantenimiento NOTA Cambie una vez al a o la buj a y el filtro de aire Una nueva buj a y un filtro de aire limpio aseguran la adecuada mezcla de combustible aire y ayudan al motor a trabajar mejor y durar m s tiempo 3 3 1 MANTENIMIENTO DEL GENERADOR El mantenimiento del generador consiste en mantener la unidad limpia y seca Utilice y guarde la unidad en un ambiente limpio y seco donde no est expuesta al polvo excesivo suciedad humedad o a vapores corrosivos Las ranuras para ventilaci n que posee el generador no deben obstruirse con nieve hojas o con cualquier otro material Revise el estado del generador frecuentemente y limpie cuando haya polvo suciedad aceite humedad u otras sustancias visibles en la superficie exterior Precauci n Nunca inserte objetos o herramientas a trav s de las ranuras para ventilaci n incluso aunque el motor no est trabajando NOTA NO utilice una manguera de jard n para limpiar el generador Es posible que el agua pueda penetrar en el sistema de combustible y causar problemas Adicionalmente si el agua penetra en el generador por las ranuras de ventilaci n puede quedar retenida en las espiras y grietas del aislamiento del embobinado del rotor y del inductor La acumulaci n de agua y suciedad en el embobinado interno del generador disminuir la resistencia del aislamiento de estos embobinados 3 3 2 LIMPIEZA DEL GEN
75. con la mano De all en adelante revise cada vez el nivel de aceite del motor antes de comenzar 28 Figura 10 Nivel de aceite LLENE EL C RTER HASTA LA PARTE BAJA DE ESTOS HILOS CON EL ACEITE DE MOTOR RECOMENDADO 2 7 2_ AGREGAR GASOLINA 21095 Nunca llene el tanque de combustible en interiores Evite derramar gasolina sobre un motor caliente Deje que el motor se enfr e completamente antes de a adir combustible Nunca llene el tanque de combustible cuando el motor est trabajando o est caliente NO encienda un cigarrillo ni fume cuando est llenando el tanque de combustible La gasolina es altamente inflamable y sus vapores son explosivos A No sobrecargue el tanque de combustible Deje siempre espacio para la expansi n del combustible Si el tanque est muy lleno el combustible puede caer sobre el motor caliente y causar un incendio o explosi n Limpie cualquier derrame de combustible inmediatamente Utilice gasolina regular SIN PLOMO con el motor del generador No utilice gasolina Premium No mezcle aceite con gasolina e Limpie el rea alrededor del conducto para gasolina retire la tapa e A ada lentamente la gasolina sin plomo al tanque de combustible Llene hasta la parte inferior del filtro de malla Cuide de no llenar
76. ctrico mientras est de pie sobre agua con los pies descalzos o con las manos o pies h medos PUEDE HABER UNA DESCARGA ELECTRICA COMO RESULTADO 22 INSTRUCCIONES IMPORTANTES SOBRE SEGURIDAD GUARDE ESTAS INSTRUCCIONES El fabricante sugiere que estas reglas para la operaci n segura se copien y publiquen cerca del sitio de instalaci n de la unidad Debe insistirse en la seguridad para todos los operadores y potenciales operadores de este equipo El C digo El ctrico Nacional NEC equiere que el marco y las partes externas que son conductores el ctricos est n conectadas en forma apropiada a una conexi n a tierra aprobada Los c digos el ctricos locales pueden asimismo requerir una apropiada conexi n a tierra del generador Consulte con un electricista local los requerimientos de conexi n a tierra para su rea Use un circuito interruptor de falla de tierra en cualquier rea h meda o altamente conductiva como estanter as de metal o trabajos en acero No use cables el ctricos gastados pelados deshilachados o de alg n modo da ados con el generador Antes de realizar cualquier mantenimiento al generador desconecte los cables de bater a de arranque del motor si los hubiera para evitar un arranque accidental Desconecte primero el cable del borne de la bater a indicado como NEGATIVO NEG o Reconecte ese cable al final En caso de un accidente causado por descarga el ctrica apague inmediatamente la fuente de ene
77. de at least once each season Follow the requirements in the Maintenance Schedule NOTE Once a year replace the spark plug and replace the air filter A new spark plug and clean air filter assure proper fuel air mixture and help the engine run better and last longer 3 9 1 GENERATOR MAINTENANCE Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material Check the cleanliness of the generator frequently and clean when dust dirt oil moisture or other foreign substances are visible on its exterior surface caution Never insert any object or tool through the air cooling slots even if the engine is not running NOTE DO NOT use a garden hose to clean generator Water can enter the engine fuel system and cause problems In addition if water enters the generator through cooling air slots some water will be retained in voids and crevices of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings 3 3 2 TO CLEAN THE GENERATOR Use a damp cloth to wipe exterior surfaces clean A soft bristle brush may be used to loosen caked on dirt oil etc
78. de leurs pi ces pour fonctionner comme pr vu La pr sente garantie ne couvre pas les r parations lorsque le probl me de la ou les pi ce s ou du moteur d coule d une utilisation normale Les d faillances caus es par toute cause ext rieure ou tout cas de force majeure tel qu un choc un vol un acte de vandalisme une meute une guerre un holocauste nucl aire un incendie un gel la foudre un s isme une temp te la gr le une ruption volcanique l eau ou une inondation une tornade ou un ouragan Les dommages dus des rongeurs et ou insectes Les produits modifi s ou alt r s d une fa on n ayant pas t autoris e par crit par Generac Les dommages accessoires importants ou indirects caus s par des d faillances mat rielles ou de fabrication ou par tout retard de r paration ou de remplacement de la ou des pi ce s d fectueuses Les d faillances dues une mauvaise application Les frais de t l phone de t l phone portable de fax d acc s Internet ou d autres moyens de communication Les frais d h bergement ou de transport de la ou des personne s r alisant l entretien sauf si cela est sp cifiquement inclus dans les termes d une p riode de garantie d une unit sp cifique Les d penses li es l instruction du client ou au d pannage lorsqu aucun d faut n est d tect Les quipements lou s utilis s pendant la r alisation des r parations dans le cadre de la garantie
79. del escape del motor contienen mon xido de carbono Este gas peligroso si se aspira en concentraciones suficientes puede hacerle perder la conciencia y causarle la muerte Este sistema de escape debe tener un apropiado mantenimiento El flujo adecuado y sin obstrucciones de aire para ventilaci n y refrigeraci n es cr tico para la correcta operaci n del generador No altere la instalaci n ni permita que haya siquiera un bloqueo parcial de la provisi n de ventilaci n ya que esto puede afectar seriamente la operaci n segura del generador El generador DEBE ser operado en exteriores e Este sistema de escape debe tener un apropiado mantenimiento No haga nada que pueda poner en peligro la seguridad del escape o que no cumpla con alg n c digo local o est ndar El fabricante recomienda instalar una alarma de mon xido de carbono operada con bater as en los interiores de acuerdo a las instrucciones del fabricante PELIGROS EL CTRICOS e El generador produce un voltaje peligrosamente alto que puede causar descargas el ctricas extremadamente peligrosas El generador produce voltajes peligrosamente altos al operar Evite el contacto con cables pelados terminales conexiones etc mientras la unidad est funcionando inclusive en el equipo conectado al generador Aseg rese que todas las cubiertas protecciones y barreras apropiadas se encuentren en su lugar antes de operar el generador No manipule ningun tipo de dispositivo el
80. des courroies de transmission des ventilateurs et d autres pi ces mobiles ou chaudes Ne jamais retirer tout prot ge ventilateur pendant que l unit fonctionne Certaines pi ces du g n rateur deviennent extr mement chaudes pendant le fonctionnement Rester distance du g n rateur tant qu il n a pas refroidi afin d viter des br lures graves NE PAS faire fonctionner le g n rateur sous la pluie Ne pas modifier la construction du g n rateur ni les commandes ce qui pourrait cr er une condition de fonctionnement dangereuse Ne jamais d marrer ou arr ter l unit avec les charges lectriques branch es aux prises ET avec des dispositifs branch s sous tension D marrer le moteur et le laisser se stabiliser avant de brancher les charges lectriques D brancher toutes les charges lectriques avant d arr ter le g n rateur Ne pas ins rer d objet dans les fentes de refroidissement de l unit Lors du travail sur cet quipement conserver l alerte tout moment Ne jamais travailler sur l quipement en cas de fatigue physique ou mentale Ne jamais utiliser le g n rateur ou n importe laquelle de ses pi ces comme marche Monter sur l unit peut craser et casser les pi ces et peut entrainer des conditions de fonctionnement dangereuses suite une fuite de gaz d chappement une fuite de carburant une fuite d huile etc Surles mod les d marrage lectrique d brancher le cable de batterie P
81. do se siente una ligera dificultad cuando desliza el calibrador hacia atr s y hacia adelante Si la abertura es excesivamente grande o estrecha los balancines necesitar n ajuste Para revisar la abertura de la v lvula e Afloje la contratuerca del balancin Figura 21 Utilice una llave Allen de 10 mm para girar el esp rrago esf rico pivotante mientras revisa la abertura entre el balanc n y el v stago de la v lvula con una l mina calibradora La abertura correcta es 0 002 0 004 pulgadas 0 05 0 1 mm Figura 21 Ajuste de la abertura de la v lvula Esp rrago esf rico NOTA La contratuerca del balanc n debe mantenerse en su lugar cuando se gira el esp rrago esf rico pivotante 33 MANTENIMIENTO 20 Secci n 3 Mantenimiento Sistema de generador port til Cuando la abertura de la v lvula sea la correcta sostenga el esp rrago esf rico pivotante en su lugar con la llave Allen y apriete la contratuerca del balanc n Apriete la contratuerca a un par de torsi n de 174 pulgadas libras Despu s de apretar la contratuerca vuelva a revisar la abertura de la v lvula para cerciorarse de que no cambi Coloque la nueva empaquetadura de cubierta de la v lvula Vuelva a colocar la cubierta de la v lvula NOTA Inserte los cuatro tornillos antes de apretar o no ser posible colocar todos los cuatro tornillos en su lugar Cerci rese de que la empaquetadura de cubierta de la v lvula est en su
82. e REMPLIR LE CARTER JUSQU AU FOND DE CES FILETS AVEC L HUILE DE MOTEUR RECOMMAND E 2 7 2 AJOUT DE L ESSENCE A Dd A Ne jamais remplir le r servoir d essence l int rieur viter de renverser de l essence sur un moteur chaud Laisser le moteur compl tement refroidir avant d ajouter du carburant Ne jamais remplir le r servoir d essence lorsque le moteur fonctionne ou est chaud NE PAS allumer une cigarette ni fumer lors du remplissage du r servoir d essence L essence est extr mement INFLAMMABLE et ses vapeurs sont EXPLOSIVES ATTENTION Ne pas trop remplir le r servoir d essence Toujours laisser de la place pour l expansion du carburant En cas de suremplissage du r servoir le carburant peut d border sur un moteur chaud et entra ner un incendie ou une explosion Nettoyer imm diatement toute claboussure de carburant Utiliser de l essence SANS PLOMB r guli re avec le moteur du g n rateur Ne pas utiliser de supercarburant Ne pas m langer l huile avec l essence Nettoyer l espace autour du bouchon de l orifice de remplissage d essence retirer le bouchon Ajouter lentement de l essence r guli re sans plomb dans le r servoir d essence Remplir jusqu au fond du filtre tamis Faire attention de ne pas trop rem
83. e il devra tre quip d un pare tincelles Le propri taire l op rateur du g n rateur devra garder le pare tincelles en bon tat Nettoyer et inspecter le pare tincelles de la mani re suivante Retirer l cran thermique du pot d chappement en retirant les quatre vis Retirer le pare tincelles du pot d chappement en retirant les quatre vis Inspecter l cran et le remplacer s il est tordu perfor ou endommag d une quelconque autre fa on NE PAS UTILISER un cran d fectueux Si l cran n est pas endommag le nettoyer avec un solvant du commerce Remplacer le pare tincelles et l cran thermique du pot d chappement Sch ma 20 Pare tincelles Pare tincelles 2 O 2209 090 5 6 090 MU 202090 p90909 VD cran thermique eM MAINTENANCE 2D 3 6 R GLAGE DU JEU DES SOUPAPES V rifier le jeu des soupapes dans le moteur apr s les 50 premi res heures de fonctionnement et l ajuster si cela est n cessaire IMPORTANT En cas de doute quant la r alisation de cette proc dure ou d absence des outils adapt s merci de faire r gler le jeu des soupapes du g n rateur dans le centre de r paration le plus proche s agit d une tape tres importante pour garantir la meilleure dur e de vie du moteur Pour v rifier le jeu des soupapes e S assurer que le moteur est temp rature ambiante entre 60 et 80 F S assurer que le
84. e d un disjoncteur est d pass e ce disjoncteur s ouvre et la puissance lectrique de cette prise est perdue Lire attentivement la section Ne pas surcharger le g n rateur 2 9 D MARRAGE DES MOTEURS D MARRAGE LECTRIQUE AVERTISSEMENT Ne jamais d marrer ou arr ter le moteur avec les dispositifs lectriques branch s dans les prises ET les dispositifs sous tension D brancher toutes les charges lectriques des prises de l unit avant de d marrer le moteur e S assurer que l unit est dans une position de niveau Ouvrir la soupape d arr t Sch ma 12 et 14 Mettre le bouton CHOKE Etrangleur du moteur l ext rieur sur la position Full Choke Etrangleur plein Sch ma 15 Sch ma 14 Soupape d arr t f OFF y ON Arr t 5 SOUPAPE D ARR T Pour d marrer le moteur appuyer et maintenir enfonc l interrupteur Start Run Stop D marrage Marche Arr t sur la position Start D marrage Le moteur tournera et commencera d marrer Lorsque le moteur d marre rel cher l interrupteur sur la position Run Marche Lorsque le moteur d marre mettre le bouton Choke Etrangleur sur la position 1 2 Choke Etrangleur moiti jusqu ce que le moteur fonctionne doucement et ensuite sur la position Run Marche Si le moteur vibre remettre le bouton Choke Etrangleur sur la position 1 2 Choke Etrangleur moiti
85. e de fum e flammes nues tincelles ou autre source de chaleur proximit de la batterie Porter des lunettes de protection un tablier en caoutchouc et des gants en caoutchouc lors du travail autour de la batterie Le fluide d lectrolyte de la batterie est une solution d acide sulfurique extr mement corrosive qui peut causer des br lures graves En cas d claboussure rincer imm diatement la zone l eau claire REMARQUE La batterie envoy e avec le g n rateur a t completement charg e Une batterie peut perdre une partie de sa charge lorsqu elle n est pas utilis e pendant des p riodes prolong es S il est impossible de d marrer le moteur l aide de la batterie brancher le chargeur de 12 V inclus dans la boite d accessoires voir la section Chargement de la batterie FAIRE FONCTIONNER LE GENERATEUR NE CHARGE PAS LA BATTERIE Utiliser la prise du chargeur de batterie afin de garder la batterie charg e et pr te l emploi Le chargement de la batterie doit tre effectu dans un endroit sec 1 Brancher le chargeur dans la prise jack Entr e du chargeur de batterie situ e sur le panneau de commande Brancher l extr mit de la prise de courant murale du chargeur de batterie dans une prise murale c a de 120 volts Sch ma 15 2 D brancher le chargeur de batterie de la prise murale et de la prise jack du panneau de commande lorsque le g n rateur va tre utilis Sch ma 15 Prise jack du
86. e la part de l acqu reur d origine La pr sente garantie ne s applique pas aux unit s utilis es pour de l nergie primaire au lieu du r seau lorsque le r seau lectrique principal est pr sent ou n existe normalement pas Une fois que le g n rateur a t utilis de mani re commerciale ou locative il sera consid r par la suite comme un g n rateur utilisation non personnelle dans le cadre de la pr sente garantie Toutes les indemnit s de garantie sont soumises aux conditions d finies dans le manuel des politiques proc dures et tarifs forfaitaires de garantie de Generac LA PR SENTE GARANTIE NE S APPLIQUE PAS AUX L MENTS SUIVANTS Les g n rateurs portables construits par Generac avant mai 2008 Les g n rateurs portables Generac utilisant des pi ces de rechange ne provenant pas de Generac Les co ts de maintenance et des modifications normales Les d faillances entrain es par de l essence ou de l huile contamin e ou par l utilisation de niveaux d huile non appropri s Les r parations ou diagnostics r alis s par des d positaires non agr s par Guardian Generac et non autoris s par crit par Generac Power Systems Les d faillances dues sans s y limiter l usure normale des accidents mauvaises utilisations usages abusifs n gligence ou utilisation inadapt e Comme pour tous les dispositifs m caniques les moteurs Generac n cessitent une r paration et un remplacement p riodiques
87. ecevoir le montant total de la garantie l op rateur doit entretenir le g n rateur de la fa on indiqu e dans ce manuel Certains r glages doivent tre effectu s r guli rement pour entretenir correctement le g n rateur Tous les r glages de la section Maintenance de ce manuel doivent tre effectu s au moins une fois par saison Respecter les exigences dans le tableau de Programme de maintenance REMARQUE Une fois par an remplacer la bougie d allumage et le filtre air Une nouvelle bougie d allumage et un filtre air propre garantissent un bon m lange carbur et aide le moteur mieux fonctionner et durer plus longtemps 3 3 1 MAINTENANCE DU G N RATEUR La maintenance du g n rateur consiste garder l unit propre et s che Faire fonctionner et stocker l unit dans un environnement sec et propre o il ne sera pas expos trop de poussi res de salet s d humidit ou de vapeurs corrosives Les fentes de refroidissement du g n rateur ne doivent pas tre obstru es par la neige les feuilles ou tout autre corps tranger V rifier r guli rement que le g n rateur est propre et nettoyer la poussi re les salet s l huile l eau ou les autres corps trangers qui sont visibles sur sa surface ext rieure ATTENTION Ne jamais ins rer d objet ou d outil dans les fentes de refroidissement m me si le moteur ne fonctionne pas REMARQUE NE PAS utiliser un tuyau d
88. el fill location Fuel Gauge Shows fuel level in tank Oil Fill Add oil here Recoil Starter Use to start engine manually Fuel Shut Off Valve between fuel tank and carburetor Oil Drain Use to drain engine oil 18 Battery Charger Input This receptacle allows the capability to recharge the 12 volt DC storage battery provided with the 12 Volt Adaptor Plug Charger which is included in the Accessory Box Located behind the battery charger input is a 1 50 Amp in line fuse which is inside the control panel to protect the battery 19 Battery Powers the electric starter Electric start only Figure 5 Generator Controls OPERATION Section 2 Operation dE Portable Generator System 2 2 HOURMETER The Hourmeter tracks hours of operation for scheduled maintenance There will be a CHG OIL message every 100 hours The message will flash one hour before and one hour after each 100 hour interval again providing a two hour window to perform service This message will actually begin flashing at 99 hours and disable itself at 101 hours providing a two hour window to perform the service Every 200 hours the SVC icon on the lower left hand corner of the display will flash The message will flash one hour before and one hour after each 200 hour interval providing a two hour window to perform service When the hour meter is in the Flash Alert mode the maintenance message will always
89. en cas de condition de d faut de mise la terre dans le g n rateur ou dans les dispositifs lectriques branch s La bonne mise la terre aide galement dissiper l lectricit statique qui s accumule souvent dans les dispositifs non mis la terre 2 4 2 BRANCHEMENT DES CHARGES LECTRIQUES NE PAS brancher des charges de 240 V des prises de 120 V NE PAS brancher des charges triphas es au g n rateur NE PAS brancher des charges de 50 Hz au g n rateur Laisser le moteur se stabiliser et chauffer pendant quelques minutes apr s le d marrage Brancher et mettre sous tension les charges lectriques monophas es souhait es de 120 ou 240 V c a 60 Hz Ajouter les watts ou amp res nominaux de toutes les charges brancher en m me temps Ce total ne doit pas d passer a la capacit nominale de wattage amp rage du g n rateur ou b la valeur nominale du disjoncteur de la prise fournissant l alimentation Voir la section Ne pas surcharger le g n rateur 25 NE PAS SURCHARGER LE G N RATEUR Surcharger un g n rateur au dessus de sa capacit nominale de wattage peut endommager le g n rateur et les dispositifs lectriques branch s Respecter les consignes suivantes pour emp cher la surcharge de l unit 1 Calculer le wattage total de tous les dispositifs lectriques brancher en m me temps Ce total ne doit PAS d passer la capacit de wattage du g n rateur Le wattage nominal des lum
90. eration that may be hazardous if performed incorrectly or carelessly Observe them carefully Their definitions are as follows DANGER INDICATES A HAZARDOUS SITUATION OR ACTION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY AWARNING Indicates a hazardous situation or action which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation or action which if not avoided could result in minor or moderate injury NOTE Notes contain additional information important to a procedure and will be found within the regular text body of this manual These safety warnings cannot eliminate the hazards that they indicate Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents Four commonly used safety symbols accompany the DANGER WARNING and CAUTION blocks The type of information each indicates is as follows This symbol points out important safety information that if not followed could endanger personal safety and or property of others 0 This symbol points out potential explosion hazard 2 This symbol points out potential fire hazard A This symbol points out potential electrical shock hazard GENERAL HAZARDS Never operate in an enclosed area or indoors For safety reasons the manufacturer recommends that the maintenance of this equipment is carried out by a
91. eures pour effectuer l entretien Toutes les 200 heures l ic ne SVC situ e en bas gauche de l cran clignotera Le message clignotera une heure avant et une heure apr s chaque intervalle de 200 heures laissant une marge de deux heures pour effectuer l entretien Lorsque l horom tre est en mode Flash Alert Alerte clignotante le message de maintenance s affichera toujours en alternance avec le temps coul en heures et en dixi mes Les heures feront clignoter quatre heures puis s afficheront en alternance avec le message de maintenance quatre fois jusqu ce que la r initialisation de l horom tre 100 heures CHG OIL Intervalle de changement d huile Toutes les 100 heures 200 heures SVC Intervalle du filtre air Toutes les 200 heures 2 3 CORDONS ET CONNECTEURS 2 3 1 PRISE DOUBLE 120 V C A 20 A ll s agit d une prise de 120 volts prot g e contre la surcharge par un disjoncteur de type pousser pour r enclencher de 20 A Sch ma 7 Utiliser chaque prise pour alimenter les charges lectriques monophas es de 120 V c a 60 Hz n cessitant 2 400 watts 2 4 kW ou 20 A de courant Utiliser uniquement des cordons trois fils avec mise la terre bien isol s de haute qualit congus pour 125 Volts 20 A ou plus Garder les cordons prolongateurs aussi courts que possible de pr f rence une longueur inf rieure 15 pieds afin d emp cher une chute de tension et une surchauffe
92. excesivamente Figura 11 e Coloque la tapa del combustible y limpie si se ha derramado gasolina Figura 11 Tanque de combustible Tanque de combustible x NO LLENE POR ENCIMA DEL Combustible REBORDE IMPORTANTE Es importante evitar los dep sitos de resinas en las partes del sistema de combustible tales como el carburador la manguera de combustible o el tanque durante el almacenaje Los combustibles con mezcla de alcohol llamados gasohol etanol o metanol pueden atraer humedad lo cual conduce a la separaci n y formaci n de cidos durante el almacenaje El gas cido puede da ar el sistema de combustible de un motor mientras est en almacenaje Para evitar problemas con el motor el sistema de combustible debe vaciarse antes de almacenar el equipo durante 30 d as o m s Refi rase a la secci n Almacenaje Nunca utilice productos de limpieza del motor o del carburador en el tanque de la gasolina ya que podr a ocurrir da o permanente 2 8 C MO ARRANCAR LOS MOTORES POR TRACCION ADVERTENCIA Nunca arranque ni pare un motor con dispositivos el ctricos enchufados a los tomacorrientes Y los dispositivos encendidos Desenchufe todas las cargas el ctricas de los tomacorrientes de la unidad antes de arrancar el motor Cerci rese de que la unidad est en posici n nivelada e ABRA la v lvula de corte del combustible Figuras 12 y 14 e Gire el interruptor RUN STOP arranque parada del motor a
93. exi n a tierra en el rea Figura 9 Conexi n a tierra del generador La adecuada conexi n a tierra del generador contribuir a evitar descargas el ctricas en caso de que haya una falla a tierra en el generador o en los dispositivos el ctricos conectados La conexi n a tierra adecuada tambi n ayuda a disipar la electricidad est tica que a menudo se acumula en los dispositivos no conectados a tierra 24 2 CONEXI N DE LAS CARGAS EL CTRICAS NO conecte cargas de 240 voltios a los tomacorrientes de 120 voltios NO conecte cargas trif sicas al generador NO conecte cargas de 50 Hz al generador Permita que el motor se estabilice y se caliente durante unos minutos despu s de arrancar Enchufe y active las cargas monof sicas el ctricas que desee de 120 6 240 voltios AC 60 Hz Sume la potencia nominal o amperios de todas las cargas que se van a conectar al mismo tiempo Este total no debe exceder de a la capacidad nominal del vataje amperaje del generador b la capacidad nominal del interruptor de circuito del tomacorriente que suministra la electricidad Refi rase a No sobrecargue el generador 2 5 NO SOBRECARGUE EL GENERADOR Sobrecargar un generador excediendo su potencia nominal puede ocasionar da o al generador y a los dispositivos el ctricos conectados Observe lo siguiente para evitar sobrecargar la unidad Sume la totalidad de los vatios de todos los dispositivos el ctricos que
94. gencia o utilizaci n inadecuada pero sin limitarse a ellos Como con todos los dispositivos mec nicos los motores de Generac necesitan servicio y reemplazo peri dico de piezas para funcionar en la forma para la cual fueron dise ados Esta garant a no ampara la reparaci n cuando el uso normal haya agotado la vida de una s pieza s o del motor Las fallas ocasionadas por causas externas o causas naturales tales como choque robo vandalismo mot n o guerras holocausto nuclear fuego congelaci n rayos terremotos tormentas de viento granizo erupci n volc nica agua o inundaci n tornados o huracanes Da os relacionados con roedores o infestaci n de insectos Productos que hayan sido modificados o alterados de forma no autorizada por Generac por escrito Cualesquiera da os accidentales resultantes o indirectos ocasionados por defectos en materiales o mano de obra o cualquier demora en la reparaci n o reemplazo de la s parte s defectuosa s Fallas ocasionadas por la aplicaci n indebida Gastos de tel fono tel fono celular fax acceso a Internet u otros gastos relacionados con las comunicaciones Gastos de viaje o vi ticos de la s persona s que efect e n servicio excepto como se incluya espec ficamente dentro de los t rminos de un per odo de garant a espec fico para una unidad Gastos relacionados con la instrucci n al cliente o soluci n de problemas donde no se encuentre defecto de fabricaci n Equipos en alquiler
95. gr par Generac le plus proche Tous les frais d envoi payer dans le cadre de la garantie dont le retour l usine seront support s et pay s l avance par l acqu reur le propri taire Cette garantie ne s applique qu aux g n rateurs portables de la s rie GP et n est pas transf rable par l acqu reur d origine Il est conseill de conserver les preuves d achat Si vous ne fournissez pas de preuve de la date d achat d origine la date d envoi du produit par son fabricant servira d terminer la p riode de garantie PROGRAMME DE GARANTIE Les applications des clients sont garanties pendant deux 2 ans Les applications commerciales et de location sont garanties pendant un 1 an ou 1 000 heures maximum la premi re des deux dates APPLICATION DES CLIENTS ANN ES UNE et DEUX couverture 100 cent pour cent pour la main d uvre et la les pi ce s list es il est n cessaire de pr senter une preuve d achat et de maintenance Moteur tous les composants Alternateur tous les composants APPLICATIONS COMMERCIALES DE LOCATION ANNEES UNE couverture 100 cent pour cent pour la main d ceuvre et la les pi ce s list es il est n cessaire de pr senter une preuve d achat et de maintenance Moteur tous les composants Alternateur tous les composants REMARQUE Aux fins de la pr sente garantie utilisation du consommateur d signe une utilisation m nag re personnelle ou r cr ative d
96. harger into Battery Charger Input jack located on the control panel Plug wall receptacle end of the battery charger into a 120 Volt AC wall outlet Figure 16 2 Unplug battery charger from wall outlet and control panel jack when generator is going to be in use Figure 16 Battery Charger Jack BATTERY CHARGER INPUT NOTE Do not use the battery charger for more than 48 hours at one charge 3 1 MAINTENANCE SCHEDULE Follow the calendar intervals More frequent service is required when operating in adverse conditions noted below Check Oil Level Change Oil Check Valve Clearance Service Air Filter Replace Spark Plug At Each Use Every 100 hours or Every Season Fvery Season Every 200 hours or Every Season Every Season Change oil after first 30 hours of operation then every season Change oil and oil filter every month when operating under heavy load or in high temperatures Clean more often under dirty or dusty operating conditions Replace air filter parts if they cannot be adequately cleaned Check valve clearance and adjust if necessary after first 50 hours of operation and every 100 hours thereafter 3 2 PRODUCT SPECIFICATIONS 3 2 1 GENERATOR SPECIFICATIONS hated tnr e dr Raman 7 0 8 0 KW Surge POWER 8 7 12 0 kW Rated AC Voltage triente 120 240 Rated Max AC Load Current 240V 7 0 8 0 KW 25 Amps 30 Amps Current 120
97. haust system must be properly maintained Do nothing that might renderthe exhaust system unsafe or in noncompliance with any local codes and or standards The manufacturer recommends installing a battery operated carbon monoxide alarm indoors according to the manufacturers instructions ELECTRICAL HAZARDS The generator produces dangerously high voltage when in operation Avoid contact with bare wires terminals connections etc while the unit is running even on equipment connected to the generator Ensure all appropriate covers guards and barriers are in place before operating the generator Never handle any kind of electrical cord or device while standing in water while barefoot or while hands or feet are wet DANGEROUS ELECTRICAL SHOCK MAY RESULT The National Electric Code NEC requires the frame and external electrically conductive parts of the generator be properly connected to an approved earth ground Local electrical codes may also require proper grounding of the generator Consult with a local electrician for grounding requirements in the area Use a ground fault circuit interrupter in any damp or highly conductive area such as metal decking or steel work Do not use worn bare frayed or otherwise damaged electrical cord sets with the generator Before performing any maintenance on the generator disconnect the engine starting battery if equipped to prevent accidental start up Disconnect the cable from the battery pos
98. hongo de 5 coloque las tuercas de capuch n de 5 6 24 Figura 1 Ensamblaje de las ruedas 2 TUERCAS DE BLOQUEO 1 2 PERNOS DE 5 16 2 ARANDELAS PLANAS 5 16 2 RUEDAS 2 ARANDELAS PLANAS 1 2 2 PERNOS DE EJE PATA 4 SOPORTE DE LA PATA 4 TUERCAS gt 2 DE 5 16 2 DEFENSAS DEGOMA Figura 2 Instalaci n del kit de manija RETIRE DESECHE EL PERNO DE CABEZA CURVA RETIREY REUTILICE LA TUERCA DE CAPUCH N TUERCA DE CAPUCH N PERNO CABEZA ENSAMBLE DE DE HONGO LA MANIJA ESCALA 0 200 1 2 2 CONEXI N DEL ARRANQUE ARRANQUE ELECTRICO UNICAMENTE La unidad ha sido deliberadamente enviada con el cable del arranque desconectado Para conectar el arranque 1 Ubique el cable del arranque posee una etiqueta colgante como se ilustra en la Figura 3 2 Coloque la funda de vinilo en el cable del arranque 3 Retire la tuerca y la arandela del v stago del arranque 4 Coloque el cable del arranque en el v stago y vuelva a colocar la arandela y la tuerca Figura 3 Conexi n del arranque 2 1 CONOZCA EL GENERADOR Lea el manual del usuario y las reglas de seguridad antes de utilizar el generador Compare el generador con las figuras 4 a la 6 para familiarizarse con la ubicaci n de varios controles y ajustes Guarde este manual para referencia futura 1 Tomacorriente d plex de 120 voltios AC 20 Amp Suministra e
99. i res peut tre indiqu sur les ampoules Le wattage nominal des outils des appareils et des moteurs se trouve g n ralement sur une tiquette ou un autocollant appos e sur le dispositif Si l appareil l outil ou le moteur n indique pas le wattage multiplier la valeur nominale des volts fois la valeur nominale des amp res afin de d terminer les watts volts x amp res watts Certains moteurs lectriques tels que ceux induction n cessitent environ trois fois plus de watts d alimentation pour le d marrage que pour le fonctionnement Cette surtension d alimentation dure seulement quelques secondes lors du d marrage des moteurs en question S assurer de laisser un wattage de d marrage lev lors du choix des dispositifs lectriques pour brancher le g n rateur Calculer les watts n cessaires pour d marrer le moteur le plus grand FONCTIONNEMENT OD 2 Ajouter ce chiffre les watts de fonctionnement de toutes les autres charges branch es Le Guide de r f rence de wattage sert d terminer combien d l ments le g n rateur peut faire fonctionner en m me temps REMARQUE Tous les chiffres sont arrondis Voir les tiquettes sur l unit pour conna tre les exigences de wattage 2 6 GUIDE DE R F RENCE DE WATTAGE Section 2 Fonctionnement G n rateur portable Dispositif Watts de fonctionnement Climatiseur 12 000 Btu 1700 Climatiseur 24 000 Btu
100. ible Pump 1 HP 2000 Submersible Pump 1 2 1500 dn 800 to 1050 Table Saw 10 1750 10 2000 Tele 0 es nement 200 to 500 A 1000 to 1650 Weed AM suerte teme EE ida iind 500 Allow 3 times the listed watts for starting these devices 2 1 BEFORE STARTING THE GENERATOR Prior to operating the generator engine oil and gasoline will need to be added as follows 2 7 1 ADDING ENGINE OIL All oil should meet minimum American Petroleum Institute API Service Class SJ SL or better Use no special additives Select the oil s viscosity grade according to the expected operating temperature also see chart Above 40 F use SAE 30 Below 40 F and down to 10 F use 10W 30 Below 10 F use synthetic 5W 30 Temperature Range of Expected Use caution Any attempt to crank or start the engine before it has been properly serviced with the recommended oil may result in an engine failure Place generator on a level surface Clean area around oil fill and remove oil fill cap Slowly fill engine with oil until it reaches the threads of the oil fill opening see Figure 10 Stop filling occasionally to check oil level Install oil fill cap and finger tighten securely Check engine oil level before starting each time thereafter Figure 10 Oil Level
101. icio autorizado 4 Contacte el centro de servicio autorizado 1 Gire la v lvula del combustible a ON 2 Limpie o cambie el filtro de aire 3 Llene el tanque de combustible 4 Vac e el tanque de combustible y llene con combustible nuevo 5 Conecte el cable a la buj a 6 Cambie la buj a 7 Vac e el tanque de combustible y Ilene con combustible nuevo 8 Coloque la perilla reguladora de flujo en la posici n No Choke 9 Llene el c rter al nivel adecuado 10 Contacte el centro de servicio autorizado 11 Contacte el centro de servicio autorizado 12 Contacte el centro de servicio autorizado 1 Llene el tanque de combustible 2 Llene el c rter al nivel adecuado 3 Contacte el centro de servicio autorizado 1 Disminuya la carga Refi rase a No sobrecargue el generador 2 Limpie o cambie el filtro de aire 3 Contacte el centro de servicio autorizado 1 Mueva la perilla reguladora de flujo a la mitad de la posici n hasta que el motor trabaje suavemente 2 Contacte el centro de servicio autorizado 35 Secci n 5 Garant a T A z GARAN Sistema de generador port til GARANT A LIMITADA DE DOS A OS DE GENERAL POWERS SYSTEMS PARA LOS GENERADORES PORTATILES DE LA SERIE GP Durante el per odo de dos a os a partir de la fecha original de venta Generac Power Systems Inc Generac garantiza que sus generadores de la serie GP no poseen defectos de materiales ni de mano de obr
102. iltro de papel en la base del limpiador de aire Reinstale la cubierta del limpiador de aire NOTA Para pedir un nuevo filtro de aire contacte el centro de servicio autorizado m s cercano al 1 800 333 1322 3 0 LIMPIEZA DE LA PANTALLA DEL PARACHISPAS El silenciador del sistema de escape del motor posee una pantalla del parachispas Inspeccione y limpie la pantalla al menos una vez al a o Figura 20 Si utiliza la unidad regularmente inspeccione y limpie m s a menudo NOTA Si utiliza el generador en un terreno bald o boscoso cubierto con maleza o hierba deber estar equipado con un parachispas El propietario operador deber conservar el parachispas en buenas condiciones Limpie e inspeccione el parachispas como sigue Retire el protector de calor del silenciador retirando cuatro tornillos Retire el parachispas del silenciador retirando cuatro tornillos e Inspeccione la pantalla y c mbiela si est rota perforada o da ada de alguna otra forma NO UTILICE una pantalla defectuosa Si la pantalla no est da ada limpiela con un solvente comercial Cambie el parachispas y el protector de calor del sistema de escape Figura 20 Parachispas Parachispas HH e S Soo D RS S oo TI e Protector de calor 27 20 Secci n 3 Mantenimiento Sistema de generador port til 3 6
103. ives pour le syst me reproductives AVERTISSEMENT PROPOSITION 65 CALIFORNIE Ce produit contient ou met des produits chimiques susceptibles selon l tat de Californie d entrainer descancers des malformations cong nitales ou autres maladies pouvant tre nocives pour le syst me reproductif 41 Section 1 Informations g n rales INFORMATIONS E G n rateur portable G N RALES 1 1 D BALLAGE Retirer tous les l ments d emballage Enlever la boite d accessoires s par e Retirer le g n rateur du carton 1 1 1 D ACCESSOIRES V rifierle contenu de la bo te Si des pi ces sont absentes ou endommag es merci de localiser un d positaire agr au 1 888 436 3722 La bo te contient e 1 Manuel d entretien e 1 Poign e gauche e 1 Huile quart SAE 30 e 1 Poign e droite 2 Roues jamais plates 1 Pied du b ti e 1 Chargeur du connecteur adaptateur de 12 volts 1 Pied du b ti 1 Sac de mat riel contenant ce qui suit 2 Pieds en caoutchouc 2 Boulons de 0 31 po 2 Rondelles plates de 0 31 po 4 Ecrous a collet de blocage de 0 31 po 4 Boulons de 0 31 po 2 Ecrous borgnes de blocage de 0 31 po 2 Boulons d axe de 0 5 po 2 Ecrous a collet de blocage de 0 5 po 2 Rondelles plates de 0 5 po Unit s a d marrage lectrique uniquement 1 2 MONTAGE ll est n cessaire d effectuer quelques tapes de montage avant d utiliser le g
104. l antes de transportar el generador 21 REGLAS DE SEGURIDAD Sistema de generador port til PELIGROS DE ESCAPE amp UBICACI N Nunca opere en reas cerradas o interiores NUNCA lo use en el hogar ni en reas parcialmente encerradas como los garajes selo S LO en exteriores y lejos de ventanas abiertas puertas ductos de ventilaci n y en reas que no acumular n el mortal gas del escape DANGER DANGER A PELIGRO Using a generator indoors CAN KILL Utiliser un g n rateur l int rieur PEUT Si usa un generador en interiores YOU IN MINUTES VOUS TUER EN QUELQUES MINUTES MORIR EN POCOS MINUTOS Generator exhaust contains carbon Les gaz d chappement du g n rateur El escape del generador contiene monoxide This is a poison you contiennent du monoxyde de carbone mon xido de carbono Es un veneno cannot see or smell C est un gaz toxique invisible et inodore que no tiene olor ni se puede ver NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents NE JAMAIS utiliser l int rieur d une maison ou d un garage MEME S les portes et les fen tres sont ouvertes Utiliser UNIQUEMENT l EXT RIEUR et loin des fen tres portes et ventilations NUNCA lo use dentro de una casa o garaje AUN si las puertas y ventanas est n abiertas S lo selo EN EXTERIORES y lejos de ventanas puertas y ductos de ventilaci n Los humos
105. lugar Cambie la buj a Vuelva a colocar el cable de la buj a en la buj a 3 7 ALMACENAJE POR PER ODOS LARGOS Es importante evitar los dep sitos de resinas en las partes del sistema de combustible tales como el carburador la manguera de combustible o el tanque durante el almacenaje La experiencia tambi n indica que los combustibles con mezcla de alcohol llamados gasohol etanol o metanol pueden atraer humedad lo cual conduce a la separaci n y formaci n de cidos durante el almacenaje El gas cido puede da ar el sistema de combustible de un motor mientras est en almacenaje Para evitar problemas con el motor el sistema de combustible debe vaciarse antes de almacenar el equipo durante 30 d as o m s como sigue Retire toda la gasolina del tanque de combustible A 2109 A Vacie el combustible en exteriores en envases aprobados alejado de llamas expuestas Cerci rese de que el motor est fr o No fume e Arranque y mantenga el motor trabajando hasta que pare por falta de combustible Deje enfriar el motor luego drene el aceite del c rter Rellene con el grado recomendado Retire la buj a y llene alrededor de 1 2 onza 15 ml de aceite de motor en el cilindro Cubra el agujero de la buj a con un trapo Tire del arrancador de recule un par de veces para lubricar los anillos del pist n y el trecorrido del cilindro 34 CUIDADO Evite la pulverizaci n del agujero de la buj
106. mpletely drained install oil drain plug and tighten securely Fill oil sump with recommended oil See Before Starting the Generator for oil recommendations Wipe up any spilled oil Dispose of used oil at a proper collection center 3 3 6 REPLACING THE SPARK PLUG Use Champion RC14YC spark plug or equivalent Replace the plug once each year This will help the engine start easier and run better 1 Stop the engine and pull the spark plug wire off of the spark plug 2 Clean the area around the spark plug and remove it from the cylinder head Set the spark plug s gap to 0 70 0 80 mm 0 028 0 031 in Install the correctly gapped spark plug into the cylinder head Figure 17 12 Figure 17 Spark Plug Gap 3 3 7 BATTERY REPLACEMENT NOTE The battery shipped with the generator has been fully charged A battery may lose some of its charge when not in use for prolonged periods of time If the battery is unable to crank the engine plug in the 12V charger included in the accessory box see the Charging a Battery section RUNNING THE GENERATOR DOES NOT CHARGE THE BATTERY caution AN The NEGATIVE battery terminal should 1 Always be DISCONNECTED FIRST 2 Always be CONNECTED LAST Figure 18 Battery Connections BLACK NUT LOCK WASHER NEGATIVE BATTERY CABLE BLACK FLAT WASHER CABLE BOOT POSITIVE BATTERY CABLE RED Section 3 Maintenance 3 4 SERVICE AIR
107. mpreso en EE UU Manual Parte N 0G8751 Revision D 07 01 10 Impreso en EE UU S rie GP Manuel d entretien S CURIT MONTAGE e FONCTIONNEMENT D PANNAGE GARANTIE SUPPORT D POSITAIRE AGR WWW generac com ou 1 888 436 3722 7 000 et 8 000 watts G n rateur portable COMMERCIAL INDUSTRIEL RESIDENTIEL MODELES 005625 0 005626 0 005680 0 005681 0 2 ANS GENERAC AAA TABLE DES Table des mati res G n rateur portable MATIERES Introduction 39 Lire attentivement ce manuel 39 R gles de s curit 39 Index CES NOMME sus ertet retener 41 Section 1 Informations g n rales 42 1 1 e res 42 1 1 1 Boite d accessoires 42 12 42 1 2 1 Montage du kit d accessoires 42 1 2 2 Branchement du d marreur d marrage lectrique 42 Section 2 Fonctionnement 43 2 1 Bien conna tre le 43 2 2 44 2 3 Cordons et 44 2 3 1 Prise double 120 V c a 20 44 2 3
108. n Authorized Dealer Inspect the generator regularly and contact the nearest Authorized Dealer for parts needing repair or replacement Operate generator only on level surfaces and where it will not be exposed to excessive moisture dirt dust or corrosive vapors Keep hands feet clothing etc away from drive belts fans and other moving parts Never remove any fan guard or shield while the unit is operating Certain parts of the generator get extremely hot during operation Keep clear of the generator until it has cooled to avoid severe burns Do NOT operate generator in the rain Do not alter the construction of the generator or change controls which might create an unsafe operating condition Never start or stop the unit with electrical loads connected to receptacles AND with connected devices turned ON Start the engine and let it stabilize before connecting electrical loads Disconnect all electrical loads before shutting down the generator Do not insert objects through unit s cooling slots When working on this equipment remain alert at all times Never work on the equipment when physically or mentally fatigued Never use the generator or any of its parts as a step Stepping on the unit can stress and break parts and may result in dangerous operating conditions from leaking exhaust gases fuel leakage oil leakage etc On electric start models disconnect the POSITIVE Battery cable from the engine starter OR the NEGATIVE
109. n builds up in ungrounded devices 24 2 CONNECTING ELECTRICAL LOADS DO NOT connect 240 Volt loads to 120 Volt receptacles DO NOT connect 3 phase loads to the generator DO NOT connect 50 Hz loads to the generator Let engine stabilize and warm up for a few minutes after starting Plug in and turn on the desired 120 or 240 Volt AC single phase 60 Hz electrical loads Add up the rated watts or amps of all loads to be connected at one time This total should not be greater than a the rated wattage amperage capacity of the generator or b circuit breaker rating of the receptacle supplying the power See Don t Overload the Generator 2 9 DON T OVERLOAD THE GENERATOR Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected electrical devices Observe the following to prevent overloading the unit Add up the total wattage of all electrical devices to be connected at one time This total should NOT be greater than the generator s wattage capacity The rated wattage of lights can be taken from light bulbs The rated wattage of tools appliances and motors can usually be found on a data label or decal affixed to the device If the appliance tool or motor does not give wattage multiply volts times ampere rating to determine watts volts x amps watts Some electric motors such as induction types require about three times more watts of power for starting than for
110. n of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer See the Storage section Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur 2 8 STARTING PULL START ENGINES WARNING 4 Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on Unplug all electrical loads from the unit s receptacles before starting the engine Make sure the unit is in a level position OPEN the Fuel Shut off Valve Figures 12 and 14 Turn engine RUN STOP switch to ON position Figure 15 Pull engine CHOKE knob outward to FULL CHOKE position Figure 13 To start engine firmly grasp the recoil handle and pull slowly until increased resistance 15 felt Pull rapidly up and away When engine starts move choke knob to 1 2 CHOKE position until engine runs smoothly and then fully into RUN position If engine falters move choke back out to 1 2 CHOKE position until engine runs smoothly and then to RUN position Figure 12 Fuel Shut off Valve FUEL SHUT UFF g IN NOTE If engine fires but does not continue to run move choke lever to FULL CHOKE and repeat starting instructions Section 2 Operation OPERATION Portable Generator System Figure
111. na soluci n de cido sulf rico extremadamente corrosiva que puede provocar quemaduras severas Si ocurre un derrame enjuague el rea con agua limpia inmediatamente NOTA La bater a enviada con el generador ha sido cargada totalmente Una bater a puede perder algo de su carga cuando no se le usa por periodos prolongados de tiempo Si la bater a no puede arrancar el motor conecte el cargador de 12 voltios incluido en la caja de accesorios ver secci n Carga de la bater a EL FUNCIONAMIENTO DEL GENERADOR NO CARGA LA BATERIA Utilice el enchufe del cargador de la bater a para mantenerla cargada y lista para usar La recarga de la bater a debe efectuarse en un sitio seco 1 Conecte el cargador a la Toma del cargador de bater a ubicada en el panel de control Enchufe el extremo del recept culo para pared del cargador de bater a en un tomacorriente de pared de 120 voltios AC Figura 15 2 Desenchufe el cargador de bater a del tomacorriente de pared y de la toma del panel cuando vaya a utilizar el generador Figura 15 Toma del cargador de baler as TOMA DEL CARGADOR DE LA BATER A NOTA No utilice el cargador de bater as durante m s de 48 horas de una vez 3 1 PROGRAMACI N DE MANTENIMIENTO Siga los intervalos del calendario Se requiere servicio m s frecuente cuando el equipo funcione en condiciones adversas como las mencionadas a continuaci n Revise el nivel de aceite Cambie el aceite
112. nce Essence vici e 5 Fil de bougie d branch de la bougie d allumage Bougie d allumage d fectueuse Pr sence d eau dans l essence Sur tranglement des gaz 9 Niveau d huile faible 10 M lange d essence trop riche 11 Soupape d admission bloqu e en position ouverte ou ferm e 12 Perte de compression du moteur 1 Panne d essence 2 Niveau d huile faible 3 Erreur au niveau du moteur 1 Charge trop lev e 2 Filtre air sale 3 R paration n cessaire du moteur 1 trangleur ouvert trop t t 2 M lange trop riche ou trop pauvre dans le carburateur Section 4 D pannage D PANNAGE G n rateur portable SOLUTION 1 R armer le disjoncteur 2 V rifier et r parer 3 Brancher un autre dispositif en bon tat 4 Contacter un centre d entretien agr 1 D brancher la charge lectrique court circuit e 2 Voir la section Ne pas surcharger le g n rateur 3 Contacter un centre d entretien agr 4 Contacter un centre d entretien agr Mettre la soupape d arr t sur ON Marche Nettoyer ou remplacer le filtre air Remplir le r servoir d essence Vidanger le r servoir d essence et le remplir avec de l essence nouvelle 5 Brancher le fil la bougie d allumage Remplacer la bougie d allumage Vidanger le r servoir d essence et le remplir avec de l essence nouvelle Placer le levier d trangleur sur la position No Choke A
113. ncer birth defects and other reproductive harm Section 1 General Information Portable Generator System GENERAL INFORMATION 1 1 UNPACKING e Remove all packaging material Remove separate accessory box Remove the generator from carton 1 1 1 ACCESSORY BOX Check all contents If any parts are missing or damaged locate an authorized dealer at 1 888 436 3722 Contents Include Owner s Manual e 1 Left Handle Assembly e 1 Quart Oil SAE 30 1 Right Handle Assembly 2 Never Flat Wheels 1 Frame Foot e 1 12 volt Adapter Plug 1 Foot Support Charger 1 Hardware Bag containing the following 2 Rubber Feet 2 5 16 Bolts 2 5 16 Flat Washers 4 5 16 Locking Flange Nuts 4 5 16 Carriage Bolts 2 5 16 Locking Cap Nuts 2 1 2 Axle Bolts 2 1 2 Locking Flange Nuts 2 1 2 Flat Washers Electric start units only 1 2 ASSEMBLY The generator requires some assembly prior to using it If problems arise when assembling the generator please call the Generator Helpline at 1 888 436 3722 1 2 1 ASSEMBLING THE ACCESSORY KIT The wheels are designed into the unit to greatly improve the portability of the generator NOTE The wheels are not intended for over the road use 1 Refer to Figure 1 and install Wheels as follows e Slide the 1 2 Axle Bolt through the 1 2 Washer the Wheel and Wheel bracket on frame e Install 1 2 Locking Flange Nuts onto
114. nerg a el ctrica para el funcionamiento de la iluminaci n el ctrica electrodom sticos herramientas y cargas de motor de 120 voltios AC 20 Amp monofasica 60 Hz 2 Tomacorriente de seguridad de 120 240 voltios AC 30 Amp Suministra energ a el ctrica para el funcionamiento de la iluminaci n el ctrica electrodom sticos herramientas y cargas de motor de 240 voltios AC 30 Amp monof sica 60 Hz 3 Interruptores de circuito AC Cada tomacorriente tiene un interruptor de circuito que se presiona para reiniciar para proteger al generador contra sobrecarga el ctrica Figura 4 Panel de control Contador horario Lleva la cuenta de las horas de funcionamiento Filtro de aire Filtra la toma de aire seg n penetra al motor Perilla reguladora de flujo Se utiliza para arrancar un motor fr o Tanque de combustible El tanque tiene una capacidad de 6 6 galones EE UU 25 1 de combustible 8 Terminal de conexi n a tierra Conecte aqu el generador a una conexi n a tierra aprobada Refi rase a la secci n Conexi n a tierra del generador para m s informaci n 9 Interruptor para encendido apagado Controla el funciona miento del generador Si FUNCIONAMIENTO 10 Silenciador Contribuye a disminuir el ruido del motor 11 Manijas Pivotan y se repliegan para almacenaje Presione el bot n de resorte para mover las manijas
115. nodore que no tiene olor ni se puede ver NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents NE JAMAIS utiliser l int rieur d une maison ou d un garage MEME S les portes et les fen tres sont ouvertes Utiliser UNIQUEMENT l EXT RIEUR et loin des fen tres portes et ventilations NUNCA lo use dentro de una casa o garaje AUN si las puertas y ventanas est n abiertas S lo selo EN EXTERIORES y lejos de ventanas puertas y ductos de ventilaci n 2 4 1 MISE A LA TERRE DU GENERATEUR Le National Electrical Code Code lectrique national exige que le b ti et que les pi ces externes lectriquement conductrices de ce g n rateur soient correctement reli es une terre approuv e Sch ma 9 Les codes lectriques locaux peuvent galement exiger la bonne mise la terre de l unit A cette fin brancher un fil toronn en cuivre de 10 AWG calibre am ricain des fils la borne de mise a la terre et une tige en cuivre conduite la terre ou une tige la terre lectrode en laiton fournit une protection appropri e contre les lectrocutions Cependant les codes locaux peuvent fortement varier Consulter un lectricien local pour connaitre les exigences de mise la terre dans la r gion Sch ma 9 Mise la terre du g n rateur La bonne mise la terre du g n rateur aidera emp cher une lectrocution
116. ns sur la v rification du niveau d huile Le niveau d huile doit tre v rifi avant chaque utilisation ou au minimum toutes les huit heures de fonctionnement Il est n cessaire de conserver un certain niveau d huile 3 3 5 CHANGEMENT DE L HUILE Changer l huile apr s les 30 premi res heures de fonctionnement Changer l huile toutes les 100 heures ou chaque saison par la suite Changer l huile plus souvent en cas d utilisation de cette unit dans un environnement sale OU poussi reux ou dans des temp ratures tr s lev es ATTENTION De l huile chaude peut entra ner des br lures Laisser le moteur refroidir avant de vidanger l huile Eviter un contact prolong ou r p t de la peau avec de l huile usag e Laver minutieusement les zones expos es avec du savon Respecter les instructions suivantes pour changer l huile alors que le moteur est encore chaud Nettoyer la zone autour du tuyau de vidange d huile Retirer le bouchon de vidange d huile du moteur et le bouchon pour le remplissage d huile afin de vidanger toute l huile dans un r cipient adapt Lorsque l huile est totalement vidang e revisser le bouchon de vidange d huile et le resserrer solidement Remplir le carter d huile avec l huile recommand e voir la section Avant le d marrage du g n rateur pour les recommandations sur l huile utiliser Nettoyer toute trace d huile renvers e liminer l huile us
117. nte a las 99 horas y se desconectar autom ticamente a las 101 horas permitiendo un espacio de dos horas para efectuar el servicio Cada 200 horas el icono SVC destellar en la esquina inferior izquierda la pantalla El mensaje destellar una hora antes y una hora despu s de cada intervalo de 200 horas de nuevo proporcionando un espacio de dos horas para efectuar el servicio Cuando el contador horario est en la modalidad de destello de alerta el mensaje de mantenimiento siempre se alternar con el tiempo transcurrido en horas y d cimas Las horas destellar n cuatro veces luego se alternan con el mensaje de mantenimiento cuatro veces hasta que el medidor se reinicia autom ticamente 100 horas CHG OIL Intervalo para cambio de aceite Cada 100 h 200 horas SVC Intervalo para el filtro de aire Cada 200 h 2 3 JUEGOS DE CABLES Y ENCHUFES DE CONEXION 2 3 1 TOMACORRIENTE D PLEX DE 120 VAC 20 AMP Este es un tomacorriente de 120 voltios protegido contra sobrecarga por un interruptor de circuito de 20 Amp que se presiona para reiniciar Figura 7 Utilice cada conector para alimentar cargas de 120 voltios AC monof sicas de 60 Hz que requieran una corriente combinada de 2400 vatios 2 4 kW o 20 amperios Utilice s lo juegos de cables de alta calidad bien aislados de 3 hilos con conexi n a tierra clasificados para 125 voltios a 20 amperios o m s Secci n 2 Funcionamiento Sistema de generador por
118. ower at 30 Amps The outlet is protected by two 30 Amp push to reset circuit breakers 2 4 HOW TO USE THE GENERATOR If there are any problems operating the generator please call the generator helpline at 1 888 436 3722 DANGER PELIGRO DANGER Using a generator indoors CAN KILL Utiliser un g n rateur l int rieur PEUT Si usa un generador en interiores YOU IN MINUTES QUELQUES MINU IORIRA EN POCOS MINUTOS l les portes et les fen tres sont ouvertes Utiliser puertas y ventanas est n abiertas S lo selo EN EXTERIORES 2 4 1 GROUNDING THE GENERATOR The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground Figure 9 Local electrical codes may also require proper grounding of the unit For that purpose connecting a No 10 AWG American Wire Gauge stranded copper wire to the grounding lug and to an earth driven copper or brass grounding rod electrode provides adequate protection against electrical shock However local codes may vary widely Consult with a local electrician for grounding requirements in the area Figure 9 Grounding the Generator Proper grounding of the generator will help prevent electrical shock in the event of a ground fault condition in the generator or in connected electrical devices Proper grounding also helps dissipate static electricity which ofte
119. plir Sch ma 11 Mettre le bouchon du r servoir d essence et nettoyer toute claboussure d essence Sch ma 11 R servoir d essence R servoir d essence NE PAS REMPLIR Carburant AU DESSUS DU REBORD tion 2 Fonctionnement FONCTIONNEMENT IMPORTANT Il est important d emp cher la formation de d p ts de gomme dans les pi ces du circuit de carburant telles que le carburateur le tuyau pour combustible ou le r servoir pendant le stockage L exp rience montre galement que les carburants base d alcool appel s gazohol thanol ou m thanol peuvent absorber l humidit ce qui entra ne une s paration et la formation d acides pendant le stockage Un gaz acide peut endommager le circuit de carburant d un moteur pendant le stockage de celui ci Afin d viter tout probl me avec le moteur le circuit de carburant doit tre vid avant le stockage du moteur si celui ci est d au moins 30 jours Voir la section Stockage Ne jamais utiliser de produit nettoyant pour moteur ou carburateur dans le r servoir d essence tant donn que cela pourrait causer des dommages permanents 2 8 D MARRAGE DES MOTEURS D MARRAGE MANUEL AVERTISSEMENT Ne jamais d marrer ou arr ter le moteur avec les dispositifs lectriques branch s dans les prises ET les dispositifs sous tension e D brancher toutes les charges lectriques des prises de l unit avant de d marrer le moteur S assurer que l unit es
120. pour conna tre les exigences de mise la terre dans la r gion Utiliser un disjoncteur de fuite la terre dans toute zone humide ou tr s conductrice telle que le carter protecteur m tallique ou l aci rie Ne pas utiliser de cordons lectriques us s nus effiloch s ou autrement endommag s avec le g n rateur Avant d effectuer toute maintenance sur le g n rateur d brancher la batterie de d marrage du moteur le cas ch ant afin d emp cher un d marrage accidentel D brancher le c ble de la borne de la batterie signal e par l inscription NEGATIVE N gatif NEG ou le signe en premier Rebrancher ce c ble en dernier En cas d accident caus par lectrocution couper imm diatement la source d alimentation lectrique Si cela est impossible essayer de lib rer la victime du conducteur sous tension EVITER TOUT CONTACT DIRECT AVEC LA VICTIME Utiliser un objet non conducteur comme une corde ou une planche pour lib rer la victime du conducteur sous tension Si la victime est inconsciente assurer les premiers secours et demander une aide m dicale imm diate RISQUES D INCENDIE L essence est extr mement INFLAMMABLE et ses vapeurs sont EXPLOSIVES Ne pas produire de fum e flammes nues tincelles ou chaleur proximit de l endroit o l essence est manipul e NE JAMAIS ajouter de carburant lorsque l unit fonctionne ou est chaude Laisser le moteur compl tement refroidir avant d ajouter du carburant
121. proper ventilation of the generator Do not insert objects through unit s cooling slots Do not operate the generator if connected electrical devices overheat if electrical output is lost if engine or generator sparks or if flames or smoke are observed while unit is running Keep a fire extinguisher near the generator at all times STANDARDS INDEX In the absence of pertinent standards codes regulations and laws the published information listed below may be used as a guideline for operation of this equipment Always reference the latest revision available for the standards listed 1 NFPA No 70 NFPA HANDBOOK OF NATIONAL ELECTRIC CODE 2 Article X NATIONAL BUILDING CODE available from the American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK available from the Food and Energy Council 909 University Avenue Columbia MO 65201 4 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS available from the American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 IMPORTANT SAFETY INSTRUCTIONS SAFETY RULES Portable Generator System CALIFORNIA PROPOSITION 65 WARNING Engine exhaust and some of its constituents are known to the State of California to cause cancer birth defects and other reproductive harm CALIFORNIA PROPOSITION 65 WARNING This product contains or emits chemicals known to the State of California to cause ca
122. proximit du g n rateur tout moment INDEX DES NORMES En l absence de normes codes r glementations et lois applicables les informations publi es indiqu es ci dessous peuvent servir de directive pour le fonctionnement de cet quipement Toujours se reporter la derni re r vision disponible pour les normes indiqu es 1 NFPA 70 NFPA HANDBOOK OF NATIONAL ELECTRIC CODE Manuel NFPA du code lectrique national 2 Article X NATIONAL BUILDING CODE Code de construction national disponible aupr s de l American Insurance Association 85 John Street New York N Y 10038 3 AGRICULTURAL WIRING HANDBOOK Manuel de c blage agricole disponible aupr s du Food and Energy Council 909 University Avenue Columbia MO 65201 4 ASAE EP 3634 INSTALLATION AND MAINTENANCE OF FARM STANDBY ELECTRICAL SYSTEMS Installation et maintenance des syst mes lectriques de secours pour les fermes disponible aupr s de l American Society of Agricultural Engineers 2950 Niles Road St Joseph MI 49085 5 NFPA n 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE Code relatif aux liquides inflammables et combustibles CONSIGNES DE S CURIT IMPORTANTES REGLES DE S CURIT G n rateur portable AVERTISSEMENT PROPOSITION 65 CALIFORNIE L chappement du moteur et certains de ses constituants sont susceptibles selon l tat de Californie d entrainer des cancers des malformations cong nitales ou autres maladies pouvant tre noc
123. rateur El escape del generador contiene monoxide This is a poison you contiennent du monoxyde de carbone mon xido de carbono Es un veneno cannot see or smell C est un gaz toxique invisible et inodore que no tiene olor ni se puede ver NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents NE JAMAIS utiliser l int rieur d une maison ou d un garage MEME SI les portes et les fen tres sont ouvertes Utiliser UNIQUEMENT l EXT RIEUR et loin des fen tres portes et ventilations NUNCA lo use dentro de una casa o garaje AUN si las puertas y ventanas est n abiertas S lo selo EN EXTERIORES y lejos de ventanas puertas y ductos de ventilaci n 2 4 1 CONEXI N A TIERRA DEL GENERADOR La Normativa de electricidad nacional requiere que la estructura del generador y las partes externas que conducen electricidad se conecten adecuadamente a un dispositivo de tierra que est aprobado Figura 9 Las normativas de electricidad locales tambi n podr an requerir la conexi n a tierra del generador ara ese fin conecte un cable de cobre trenzado AWG American Wire Gauge N 10 al terminal de conexi n a tierra y a una varilla de conexi n a tierra de cobre o lat n electrodo brinda adecuada protecci n contra descargas el ctricas No obstante la normativa local puede variar ampliamente Consulte con un electricista local sobre los requerimientos de con
124. reen is not damaged clean it with commercial solvent Replace the spark arrestor and muffler heat shield MAINTENANCE 20 Portable Generator System Figure 20 Spark Arrestor 3 6 ADJUSTING VALVE CLEARANCE After the first 50 hours of operation check the valve clearance in the engine and adjust if necessary Important If feeling uncomfortable about doing this procedure or the proper tools are not available please take the generator to the nearest service center to have the valve clearance adjusted This is a very important step to insure longest life for the engine To check valve clearance Make sure the engine is at room temperature 60 80 F Make sure that the spark plug wire is removed from the spark plug and out of the way Remove spark plug Remove the four screws attaching the valve cover Make sure the piston is at Top Dead Center TDC of its compression stroke both valves closed To get the piston at TDC remove the intake screen at the front of the engine to gain access to the flywheel nut Use a large socket and socket wrench to rotate the nut and hence the engine in a clockwise direction while watching the piston through the spark plug hole The piston should move up and down The piston is at TDC when it is up as high as it can go Insert a 0 002 0 004 inch 0 05 0 1mm feeler gauge between the rocker arm and valve stem Correct clearance is when
125. rg a el ctrica Si esto no es posible intente liberar a la v ctima del conductor vivo EVITE EL CONTACTO DIRECTO CON LA V CTIMA Une un implemento no conductivo como una soga o una tabla para liberar a la v ctima del conductor vivo Si la v ctima est inconsciente aplique los primeros auxilios y consiga ayuda m dica inmediatamente PELIGRO DE INCENDIO La gasolina es altamente INFLAMABLE y sus vapores son EXPLOSIVOS No permita que fumen haga fuegos abiertos chispas o calor en la vecindad mientras manipula gasolina Nunca a ada gasolina mientras la unidad est funcionando o est caliente Deje enfriar al motor completamente antes de a adir combustible Nunca llene el tanque de combustible en el interior de la casa Cumpla todas las leyes que regulan el almacenamiento y manipulaci n de gasolina No sobrecargue el tanque de combustible Deje siempre espacio para la expansi n del combustible Si el tanque est sobrecargado el combustible puede desparramarse sobre el motor caliente y causar un INCENDIO o una EXPLOSI N Nunca almacene el generador con combustible en el tanque donde los vapores de la gasolina pueden alcanzar llamas abiertas chispas o fuegos piloto como en una chimenea calentador de agua o secador de ropa Puede generarse un INCENDIO o una EXPLOSI N Deje enfriar la unidad completamente antes de almacenarse Limpie cualquier derrame de combustible inmediatamente Aseg rese de que no se haya dejado materi
126. rises du panneau du g n rateur Ne jamais d marrer ou arr ter le moteur avec les dispositifs lectriques branch s et sous tension Laisser le moteur fonctionner circuit ouvert pendant plusieurs minutes pour stabiliser les temp ratures internes du moteur et du g n rateur Mettre l interrupteur Run Stop Marche Arr t sur la position OFF Arr t Fermer la vanne de combustible 2 11 SYSTEME D ARR T DE BAS NIVEAU D HUILE Le moteur est quip d un d tecteur de bas niveau d huile qui arr te le moteur automatiquement lorsque le niveau d huile chute en dessous d un niveau sp cifique Si le moteur s arr te tout seul et que le r servoir d essence a assez d essence v rifier le niveau d huile du moteur 2 11 1 D TECTION DE BAS NIVEAU D HUILE Si le syst me d tecte un niveau d huile bas pendant le fonctionnement le moteur s arr te Le moteur ne fonctionnera pas tant que de l huile n aura pas t rajout e pour atteindre le bon niveau 48 2 12 CHARGEMENT DE LA BATTERIE UNIT S A DEMARRAGE ELECTRIQUE UNIQUEMENT N A Les batteries rechargeables mettent un gaz hydrog ne explosif lors du rechargement Un m lange explosif restera autour de la batterie longtemps apr s son chargement La plus petite tincelle peut enflammer l hydrog ne et causer une explosion Cette explosion peut faire voler en clats la batterie et causer la c cit ou d autres blessures graves N A AN Ne pas produir
127. rt til Dispositivo Vatios en consumo Abridor de puerta de garaje 500 a 750 Aire acondicionado 12 000 1700 Aire acondicionado 24 000 Btu 3800 Aire acondicionado 40 000 Btu 6000 Bomba colectora 800 a 1050 Bomba eyectora 800 Bomba sumergible 1 2 HP 1500 Bomba sumergible 1 HP 2000 Bomba sumergible 1 1 2 HP 2800 Bombilla a one dre 100 ceci a ee 500 Gafelera y s a sine ie 1750 Calentador de rea alimentado con aceite 30 000 Btu 150 Calentador de rea alimentado con aceite 85 000 Btu 225 Calentador de rea alimentado con aceite 140 000 Btu 400 Cargador de bater as 20 500 Compresor 1 2 HP uu tal aia adie RR 1400 Compresor 3 4 HP 1800 Compresor 1 aus i eer et Rega 2000 GOntgelador asas amina nisa ayu 700 De shumidificador eer m RR Ea 650 Entriador d Ce aceite ur tap anra 1100 Estufa el ctrica por resistencia 1500 Horno microondas 700
128. rto ensamblaje para poder utilizarlo Si surgen problemas al ensamblar el generador llame a la l nea de ayuda del generador al 1 888 436 3722 1 2 1 ENSAMBLAJE DEL KIT DE ACCESORIOS Las ruedas est n dise adas dentro de la unidad para mejorar significativamente la capacidad de transporte del generador NOTA Las ruedas no est n dise adas para uso en carretera 1 Refi rase a la Figura 1 e instale las ruedas como sigue e Deslice el perno del eje de 1 2 a trav s de la arandela plana de Y la rueda y el soporte de la rueda en la estructura e Instale las tuercas de bloqueo de 2 con brida en el perno con brida de 1 2 2 Refi rase a la Figura 1 e instale la pata de la estructura el soporte de la pata y las patas de goma como se ilustra Deslice el v stago de la pata de goma a trav s del soporte de la pata y de la pata de la estructura coloque tuercas de bloqueo de 5 8 con brida deslice el perno de 5 6 a trav s de la arandela plana de 5 6 y luego a trav s de los agujeros en el larguero de la estructura Deslice la pata de la estructura en los pernos de 5 16 coloque las tuercas de bloqueo de 54g con brida 3 Refi rase a la Figura 2 e instale las manijas como siguen Retire los pernos superiores de cabeza curva y las tuercas de capuch n las tuercas de capuch n se reutilizar n Deslice el ensamble de manija sobre el tubo de la estructura alineando los dos agujeros Introduzca los pernos cabeza de
129. running This surge of power lasts only a few seconds when starting such motors Make sure to allow for high starting wattage when selecting electrical devices to connect to the generator OPERATION OD 1 Figure the watts needed to start the largest motor 2 Add to that figure the running watts of all other connected loads The Wattage Reference Guide is provided to assist in determining how many items the generator can operate at one time NOTE All figures are approximate See data label on appliance for wattage requirements 2 6 WATTAGE REFERENCE GUIDE Section 2 Operation Portable Generator System Device coi e E AE Running Watts Air Conditioner 12 000 Btu 1700 Air Conditioner 24 000 Btu 3800 Air Conditioner 40 000 Btu 6000 Battery Charger 20 500 A A 1000 GAIN SAW ad dd 1200 Circular Saw 6 1 2 800 to 1000 Clothes Dryer Electric 5750 Clothes Dryer Gas 700 Clothes Washer 1150 0100 Maker tacos ortae redis 1750 Compressor 1 HP 2000 Compressor 3 4 HP 1800 Compressor 1 2 HP 1400 Curlirid MOM sis iue l u uyu su ain Rx ER em n ES 700
130. s caused by any external cause or act of God such as collision theft vandalism riot or wars nuclear holocaust fire freezing lightning earth quake windstorm hail volcanic eruption water or flood tornado or hurricane Damage related to rodent and or insect infestation Products that are modified or altered in a manner not authorized by Generac in writing Any incidental consequential or indirect damages caused by defects in materials or workmanship or any delay in repair or replacement of the defective part s Failure due to misapplication Telephone cellular phone facsimile internet access or other communication expenses Living or travel expenses of person s performing service except as specifically included within the terms of a specific unit warranty period Expenses related to customer instruction or troubleshooting where no manufacturing defect is found Rental equipment used while warranty repairs are being performed Overnight freight or special shipping costs for replacement part s Overtime holiday or emergency labor Starting batteries fuses light bulbs and engine fluids THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED SPECIFICALLY GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you GENERAC S ONL
131. si no se evita puede traer como resultado un da o menor o moderado NOTA Las notas contienen informaci n adicional importante para un procedimiento y se les encontrar dentro del cuerpo del texto regular de este manual Estas advertencias de seguridad no pueden eliminar los peligros que indican El sentido com n y un estricto cumplimiento de las instrucciones especiales cuando se realiza un servicio son esenciales para evitar accidentes Cuatro s mbolos de seguridad usados com nmente acompa an los bloques de PELIGRO ADVERTENCIA y CUIDADO El tipo de informaci n que cada uno indica es como sigue Este s mbolo se ala importante informaci n de seguridad que si no se sigue puede poner en peligro la seguridad personal y o las propiedades de otros 0 Este s mbolo indica un peligro potencial de explosi n 2 Este s mbolo indica un peligro de incendio Este s mbolo indica un peligro potencial de descarga el ctrica PELIGROS GENERALES e Nunca opere en reas cerradas o interiores Porrazones de seguridad el fabricante recomienda que el mantenimiento de este equipo sea llevado a cabo por un concesionario autorizado Inspeccione el generador con regularidad y p ngase en contacto con el concesionario autorizado m s cercano si necesita repararlo o conseguir repuestos Opere el generador s lo en superficies planas y donde no est expuesto a excesiva humedad suciedad polvo o vapores corrosivos
132. t ou de la salet dans l essence entraineront des probl mes dans le carburateur et le circuit de carburant e Si cela est possible stocker l unit l int rieur et le recouvrir afin de le prot ger de la salet et de la poussi re S ASSURER DE VIDER LE RESERVOIR D ESSENCE e S il n est pas possible de vider le r servoir d essence et que l unit est rang e pendant une longue p riode ajouter un stabilisateur d essence disponible dans le commerce l essence afin d augmenter la dur e de vie de l essence e Couvrir l unit avec une protection adapt e ne retenant pas l humidit N A AN NE JAMAIS couvrir le g n rateur alors que le moteur et la zone du pot d chappement sont chauds 4 1 GUIDE DE D PANNAGE PROBLEME Le moteur tourne mais aucun courant alternatif n est produit Le moteur fonctionne bien mais connait des d faillances lorsque des charges sont branch es Le moteur ne d marre pas ou d marre et connait des d faillances Le moteur s arr te pendant le fonctionnement A coups ou d clin du moteur 1 Disjoncteur est ouvert 2 Cordon mal branch ou d fectueux 3 Dispositif branch d fectueux 4 Erreur au niveau du g n rateur 1 Court circuit dans l une des charges branch es 2 Surcharge du g n rateur 3 Vitesse du moteur trop faible 4 Court circuit du g n rateur La soupape d arr t est sur OFF Arr t Filtre a air sale Panne d esse
133. t til Mantenga los cables de extensi n tan cortos como sea posible preferiblemente de menos de 15 pies 4 6 m de largo para evitar las ca das de voltaje y el posible sobrecalentamiento de los cables Figura 7 Tomacorriente d plex de 120 voltios AC 20 amp 26 2 3 2 TOMACORRIENTE DE 120 240 VAC 30 AMP Utilice un conector NEMA L14 30 con su tomacorriente rote para bloquear desbloquear Conecte al enchufe un juego de cables adecuado de 4 conductores con conexi n a tierra y a la carga deseada El juego de cables debe estar clasificado para 250 voltios AC a 30 amperios o m s Figure 8 Figura 8 Tomacorriente de 120 240 VAC 30 Amp 120V 240V 30A Utilice este tomacorriente para cargas de 120 voltios AC 60 Hz monof sicas que requieran hasta 3600 vatios 3 6 kW de energ a a 30 Amps o 240 voltios AC 60 Hz monof sicas que requieran hasta 7200 vatios 7 2 kW de energ a a 30 Amp El tomacorriente est protegido por dos interruptores de circuito de 30 Amp del tipo presione para reiniciar 2 4 COMO UTILIZAR EL GENERADOR Si surgen problemas al utilizar el generador llame a la l nea de ayuda del generador al 1 888 436 3722 DANGER DANGER A PELIGRO Using a generator indoors CAN KILL Utiliser un g n rateur l int rieur PEUT Si usa un generador en interiores YOU IN MINUTES VOUS TUER EN QUELQUES MINUTES MORIRA EN POCOS MINUTOS Generator exhaust contains carbon Les gaz d chappement du g n
134. t dans une position de niveau OUVRIR la soupape d arr t Sch ma 12 et 14 Mettre l interrupteur RUN STOP Marche Arr t du moteur sur la position ON Marche Sch ma 13 Mettre le bouton CHOKE trangleur du moteur l ext rieur sur la position FULL CHOKE Etrangleur plein Sch ma 13 Pour d marrer le moteur attraper fermement la poign e de rappel et tirer jusqu ce qu une r sistance se fasse sentir Remonter rapidement et d marrer Lorsque le moteur d marre mettre le bouton Choke Etrangleur sur la position 1 2 CHOKE Etrangleur moiti jusqu ce que le moteur fonctionne doucement et ensuite sur la position RUN Marche Si le moteur vibre remettre le levier Choke Etrangleur sur la position 1 2 CHOKE Etrangleur moiti jusqu ce que le moteur fonctionne doucement et ensuite sur la position RUN Marche Sch ma 12 Soupape d arr t SOUPAPE D ARR T REMARQUE Si le moteur chauffe mais ne continue pas fonctionner mettre le levier de l trangleur sur FULL CHOKE Etrangleur plein et r p ter les instructions de d marrage G n rateur portable O B Sch ma 13 Position de l trangleur trangleur IMPORTANT Ne pas surcharger le g n rateur Aussi ne pas surcharger les prises individuelles du panneau Ces prises sont prot g es contre la surcharge avec des disjoncteurs de type pousser pour r enclencher Si la valeur nominale d amp rag
135. t indicated by a NEGATIVE NEG or first Reconnect that cable last In case of accident caused by electric shock immediately shut down the source of electrical power If this is not possible attempt to free the victim from the live conductor AVOID DIRECT CONTACT WITH THE VICTIM Use a non conducting implement such as a rope or board to free the victim from the live conductor If the victim is unconscious apply first aid and get immediate medical help FIRE HAZARDS Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE Do not permit smoking open flames sparks or heat in the vicinity while handling gasoline Never add fuel while unit is running or hot Allow engine to cool completely before adding fuel Never fill fuel tank indoors Comply with all laws regulating storage and handling of gasoline Do not overfill the fuel tank Always allow room for fuel expansion If tank is over filled fuel can overflow onto a hot engine and cause FIRE or an EXPLOSION Never store generator with fuel in tank where gasoline vapors might reach an open flame spark or pilot light as on a furnace water heater or clothes dryer FIRE or EXPLOSION may result Allow unit to cool entirely before storage Wipe up any fuel or oil spills immediately Ensure that no combustible materials are left on or near the generator Keep the area surrounding the generator clean and free from debris and keep a clearance of five 5 feet on all side to allow for
136. tes de usarla El fabricante no puede anticipar todas las posibles circunstancias que puedan involucrar peligros Las advertencias en este manual y en las etiquetas y calcoman as fijadas en la unidad son por tanto no completamente inclusivas Si se usa un procedimiento m todo de trabajo o t cnica de operaci n que el fabricante no recomienda espec ficamente aseg rese de que sea seguro para los dem s Asimismo aseg rese que el procedimiento m todo de trabajo o t cnica de operaci n utilizada no vuelva inseguro al generador LA INFORMACI N CONTENIDA AQU SE BAS EN M QUINAS EN PRODUCCI N AL MOMENTO DE LA PUBLICACI N GENERAC SE RESERVA EL DERECHO DE MODIFICAR ESTE MANUAL EN CUALQUIER MOMENTO REGLAS DE SEGURIDAD A lo largo de esta publicaci n y en lo que respecta a las etiquetas y calcoman as fijadas en el generador los bloques de PELIGRO ADVERTENCIA CUIDADO Y NOTA se usan para alertar al personal sobre instrucciones especiales sobre una operaci n en particular que puede ser peligrosa si se ejecuta en forma incorrecta o sin cuidado Obs rvelas con cuidado Sus definiciones son como sigue PELIGRO INDICA UNA SITUACI N O ACCI N PELIGROSA QUE SI NO SE EVITA TRAER COMO RESULTADO LA MUERTE O UN DA O SERIO ADVERTENCIA Indica una acci n o situaci n peligrosa que si no se evita puede traer como resultado la muerte o un serio da o ATENCI N Indica una acci n o situaci n peligrosa que
137. the fuel tank and the unit is to be stored for some time use a commercially available fuel stabilizer added to the gasoline to increase the life of the gasoline Cover the unit with a suitable protective cover that does not retain moisture A DIE A NEVER cover the generator while engine and exhaust area are warm Section 4 Troubleshooting TROUBLESHOOTING Portable Generator System 4 1 TROUBLESHOOTING GUIDE PROBLEM Engine is running but no AC output is available Engine runs good but bogs down when loads are connected Engine will not start or starts and runs rough Engine shuts down during operation Engine hunts or falters 1 Circuit breaker is open 2 Poor connection or defective cord set 3 Connected device is bad 4 Fault in generator 1 Short circuit in a connected load 2 Generator is overloaded 3 Engine speed is too slow 4 Shorted generator circuit Fuel Shut off is OFF Dirty air filter Out of gasoline Stale gasoline Spark plug wire not connected to spark plug Bad spark plug Water in gasoline Over choking 9 Low oil level 10 Excessive rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 2 3 4 5 6 i 8 1 Out of gasoline 2 Low oil level 3 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced 1 Choke is opened too soon 2 Carburetor
138. to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer as follows Remove all gasoline from the fuel tank 14 Portable Generator System A DIG A Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do not smoke Start and run engine until engine stops from lack of fuel Allow the engine to cool then drain oil from crankcase Refill with recommended grade Remove spark plug and pour about 1 2 ounce 15 ml of engine oil into the cylinder Cover spark plug hole with rag Pull the recoil starter a couple times to lubricate the piston rings and cylinder bore caution Avoid spray from spark plug hole when cranking engine Install and tighten spark plug Do not connect spark plug wire Clean the generator s outer surfaces Check that cooling air slots and openings on generator are open and unobstructed Store the unit in a clean dry place 3 8 OTHER STORAGE TIPS Do not store gasoline from one season to another Replace the gasoline can if it starts to rust Rust and or dirt in the gasoline will cause problems with the carburetor and fuel system If possible store the unit indoors and cover it to give protection from dust and dirt BE SURE TO EMPTY THE FUEL TANK If it is not practical to empty
139. ucun trangleur 9 Remplir le carter jusqu au niveau n cessaire 10 Contacter un centre d entretien agr 11 Contacter un centre d entretien agr 12 Contacter un centre d entretien agr 1 Remplir le r servoir d essence 2 Remplir le carter jusqu au niveau n cessaire 3 Contacter un centre d entretien agr 1 Diminuer la charge voir la section Ne pas Surcharger le g n rateur 2 Nettoyer ou remplacer le filtre air 3 Contacter un centre d entretien agr 1 Placer le levier d trangleur mi chemin jusqu ce que le moteur fonctionne correctement 2 Contacter un centre d entretien agr 53 Section 5 Garantie G n rateur portable GARANTIE LIMIT E DE DEUX ANS DE GENERAC POWER SYSTEMS POUR LES GENERATEURS PORTABLES SERIE GP La soci t Generac Power Systems Inc Generac garantit que pendant une p riode de deux ann es compter de la date d achat d origine ses g n rateurs s rie GP ne pr senteront aucun d faut mat riel ni de fabrication pour les l ments et la p riode mentionn e ci apr s Generac r parera ou remplacera comme il le jugera n cessaire toute piece jug e d fectueuse apr s un examen une inspection et un test r alis s par Generac un d positaire de service de garantie agr par Generac Tout quipement d clar d fectueux par l acqu reur le propri taire doit tre retourn et examin par le d positaire de service de garantie a
140. utilizados mientras se efect en las reparaciones en garant a Flete al d a siguiente o costos especiales de env o para la s pieza s de repuesto Mano de obra con horas extras en d as festivos o de emergencia Arranque de bater as fusibles bombillas y fluidos del motor ESTA GARANT A REEMPLAZA CUALESQUIERA OTRAS GARANT AS EXPRESAS O IMPL CITAS ESPEC FICAMENTE GENERAC NO OTORGA OTRAS GARANT AS RELACIONADAS CON EL APROVECHAMIENTO O IDONEIDAD PARA UN FIN PARTICULAR Algunos estados no permiten limitaciones sobre el tiempo de duraci n de una garant a de modo que las limitaciones anteriores puede que no apliquen en su caso LA NICA RESPONSABILIDAD DE GENERAC SER LA REPARACI N O REEMPLAZO DE LA S PIEZA S DE ACUERDO A LO ESTABLECIDO ANTERIORMENTE EN NING N CASO GENERAC SER RESPONSABLE DE DA OS ACCIDENTALES O RESULTANTES INCLUSO SI TALES DA OS SEAN EL RESULTADO DIRECTO DE LA NEGLIGENCIA DE GENERAC Algunos estados no permiten la exclusi n o limitaci n de los da os accidentales o resultantes de modo que la limitaci n anterior puede que no aplique en su caso Esta garant a le otorga derechos legales espec ficos Tambi n puede tener otros derechos que var an de un estado a otro GENERAC POWER SYSTEMS INC P O BOX 8 Waukesha WI 53187 Telef 888 GENERAC 436 3722 Fax 262 544 4851 Para ubicar el distribuidor autorizado mas cercano visite nuestro sitio en Internet www generac com Parte N 0G9451 Revisi n D 10 27 08 I
Download Pdf Manuals
Related Search
Related Contents
12_13_14_radcom_jul0.. Microsoft Wireless Laser Desktop 5000 Optimus SYSTEM 747 User's Manual Manuel de l`opérateur Samsung MM-ZJ5R Manual de Usuario Leaflet 24PFL4208H_12 Released France (French) High Step2 入門 - 121ware.com Samsung WD8602R8W/XSG User Manual iP88 User Manual (English) Manual de Instalação Copyright © All rights reserved.
Failed to retrieve file