1. NOTE Be sure to note location of lamp hole in bracket relative to unit base E Figure 11 Figure A Figure B Figure D LAMP INSTALLATION This unit is listed for use with Field Controls lamps ONLY You will need to determine proper lamp selection based on duct size and desired configuration Refer to configuration table on page 6 of this manual 16 Remove tag and alcohol from lamp Wipe off lamp being sure not to touch lamp with bare hands The oils in your hands may cause the lamp to prematurely expire 17 Insert lamp through hole in bracket until lamp is snug against the bracket See Figure 12 Figure 12 permanent eye damage or blindness Never operate the UV Aire Air Purifying System out of the plenum i WARNING Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause Avoid touching the glass portion of the lamp with your hands Page 4 18 20 21 22 23 A Plug ballast plug into end of lamp and reconnect power supply See Swing securing bracket over end of lamp and hand tighten the provided wing nut on stud See Figure 13 Figure 13 Figure 14 Figure 14 Flip the red power switch to the on position Light on switch should be on indicating power Look through view port to be sure lamp is working You should see a blue glow The view port is covered with a plastic lens that blocks the UVC rays If the lamp is not glowing
2. okt E TM Ais UV AIRE AIR PURIFYING SYSTEM Model UV E For use with 12 18 and 28 Field Controls Lamps 120 240 volt application ITEMS INCLUDED IN KIT 1 UV E power unit NEMAS housing 1 Mounting Template 4 Sheet metal mounting screws 1 Angled mounting bracket 1 Flat mounting bracket 1 Instruction Sheet 1 Wing nut 2 Hex nuts 1 Lamp UV C light inhibits the growth and reproduction of germs and bacteria that circulate through a homes heating and air conditioning system The treatment is a safe silent and proven way to make your home a healthier place to live READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER OPERATOR OF THE DEVICE AFTER OPENING THE CARTON UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE SAFETY CONSIDERATIONS WARNING Never expose eyes or skin to UVC light from any source e Looking directly at the UVC light may cause permanent eye damage or blindness e Never operate the UV Aire Air Purifying System out of the plenum WARNING UV light will break down plastic materials not rated for UV exposure Examples wire insulation flex duct drain pans and humidifiers e The unit must be mounted at least 30 from the above stated type of materials e lf it is necessary to mount the unit in direct line of site of these types of materials they
3. LENGTH C MIN DISTANCE GALVANIZED 90 ELBOW Figure 15 Limited Warranty Field Controls L L C warrants that the following Field Controls L L C products sold hereunder shall be free from defects in material and workmanship under normal use for eighteen 18 months from date of manufacturing by the consumer excepting the provisions numbered below UV LAMPS BULBS Field Controls L L C warrants that the following Field Controls L L C products sold hereunder shall be free from defects in material and workmanship under normal use for ninety 90 days from date of installation by the consumer excepting the provisions numbered below Provisions Field Controls shall have no obligation in the event the customer is unable to provide receipt showing the date the customer purchased the product s or accurate date code information The product must be properly installed maintained and operated under normal conditions Field Controls shall not be liable for any consequential and incidental damages resulting from failure of a Field Controls L L C product failure to deliver delay in delivery delivery in nonconforming condition or for any breech of contract or duty between Field Controls L L C and the customer Field Controls L L C products are often intended for use in specific applications Field Controls L L C makes no warranty if a Field Controls L L C product is used in applications other than intended Field Contr
4. OFF eee SWITCH i o KOKIRI 1 1 jest e LL GREEN TO G Wire Clip WHITE TO L2 BLACK TO L1 NDUIT INSTALLER SUPPLIED WIRING OPTION 2 WIRING OPTION 3 240 Volt 120 Volt CIRCUIT CIRCUIT BREAKER BREAKER PANEL PANEL 15 AMP 15 AMP CURCUIT CURCUIT Figure 9 Figure 8 permanent eye damage or blindness Never operate the UV Aire Air Purifying System out of the plenum Avoid touching the glass portion of the lamp with your hands Page 3 WARNING Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause 15 Determine whether to use flat or angled bracket Refer to UV Aire Configurations in Section III for aid in this decision a Flat Bracket Installation i Remove the two hex nuts and flat bracket from included bagged hardware il Install the flat bracket and secure to the unit base with the hex nuts provided See Figure 10 b Angled Bracket Installation NOTE For angled bracket mounting refer to specifications outlined by Diagram A for mounting distances in the Angled Lamp Mounting Bracket Specifications in section Ill i Remove the two hex nuts and angled bracket from included bagged hardware il Install the angled bracket and secure to the unit base with the hex nuts provided See Figure 11 The angle bracket may be mounted in 4 positions allowing the bulb to either be angled up and down or left to right depending upon duct design Figures A D
5. make sure the wiring is correct and that the ballast is plugged in securely to lamp If lamp still does not glow contact technical support at 1 252 522 3031 for further assistance After unit has been found to be working properly note date of installation on inside cover close cover and engage latch Apply supplied wire tie to latch or other locking mechanism to provide safety WARNING Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause permanent eye damage or blindness Never operate the UV Aire Air Purifying System out of the plenum Avoid touching the glass portion of the lamp with your hands Page 5 lll BULB MOUNTING BRACKET SELECTION AND INSTALLATION The UV AIRE units come with an angled mounting bracket and flat mounting bracket to position the bulb either straight or at an angle Choose one or the other bracket method best suited for your needs Refer to the configurations chart below when making your selection UV INTENSITY UV Aire Configurations an ee Better Standard 90 Installation Standard 90 Installation Flat Bracket Flat Bracket Fits a minimum 12 Duct Fits a minimum 18 Duct Patent Pending 45 Patent Pending 45 Installation Installation Angled Bracket Angled Bracket Fits a minimum 8 Duct Fits a minimum 14 Duct ANGLED LAMP MOUNTING BRACKET SPECIFICATIONS Use the specifications below to determine allowable clearances for
6. must be shielded with aluminum foil aluminum foil tape or sheet metal D gt aa 2630 Airport Road Kinston NC 28504 Phone 252 522 3031 FAX 252 522 0214 www fieldcontrols com l GENERAL INFORMATION This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or condition nor for use in the mitigation treatment or prevention of any disease or condition There are different size units available depending on the square footage of your home See chart below for determining your homes needs Lamp Length aera HEM Lamp Intensity at 1 Recommended Er Width oF meter Max Sq Feet T2020 05 60 T2020 05 e0 CIEI WARNING Before installing or servicing a humidifier air filter heat system or this unit etc always turn all power OFF and have units unplugged Electrical shock can cause personal injury or death Never expose eyes or skin to direct UVC light from any source ll INSTALLATION 1 Determine a suitable location on either the supply or return for the unit as shown in Figure 1 The unit must be ieee ile ee mounted at least 3 feet from any flex duct type material a NOTE Unit can only be mounted in a vertical position as noted on inside cover label T 2 Apply mounting template to air duct as shown in Figure 2 me Mount in either location 3 Drill 1 8 diameter mounting holes at positions indicated on template See Figure 2 Foundation W
7. proper mounting of the UV Aire unit on the duct Center of Lamp Mount Diagram A LAMP OFFSET DIMENSIONS Lamp Lamp Part Length No 12 8 1 2 6 1 2 46365401 18 13 1 2 10 5 16 46365402 28 21 3 8 16 1 4 46365403 permanent eye damage or blindness Never operate the UV Aire Air Purifying System out of the plenum i WARNING Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause Avoid touching the glass portion of the lamp with your hands Page 6 IV MAINTENANCE 1 2 Inspect and clean lamp at least every 6 months Replace your UV Aire Air Purifying System lamp once a year to maintain the lamps maximum output intensity The lamp should operate continuously for maximum lamp life and light effectiveness V REPLACEMENT PROCEDURE A VERY IMPORTANT Turn switch on unit to OFF position and disconnect from power source 2 3 4 oi 8 Remove wire tie or locking mechanism from latch on unit Unplug ballast plug from end of lamp Remove the wing nut on securing bracket Swing out securing bracket to clear lamp Slide lamp out carefully NOTE When replacing the lamp always wipe off lamp before installing Replace lamp following the appropriate procedure based on bracket selection in the installation section UV lamps contain a small amount of mercury like a typical fluorescent lamp Check with your local waste management author
8. all 4 Using a 2 hole saw drill out lamp hole as shown on template See Figure 2 5 Drill a 7 8 inspection hole as shown on template See Unit Figure 2 Remove template Figure 1 Mount unit to duct using the 4 supplied sheet metal screws See Figure 3 Drill 7 8 Hole Drill 1 8 Diameter Holes Typical 4 Places Drill 2 Hole Using Hole Saw Mounting Template Figure 2 Figure 3 permanent eye damage or blindness Never operate the UV Aire Air Purifying System out of the plenum Avoid touching the glass portion of the lamp with your hands Page 2 WARNING Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause A WARNING Disconnect electrical power supply before wiring 9 Connect to an appropriate power source such as an AC power disconnect box or to a circuit breaker panel See Figure 8 10 Determine length of wire and conduit necessary according to power connection and install wiring conduit and water tight connector as shown in example figure 4 Supplied by installer 11 Acces Cover Figure 5 12 Push power source wires through bushing in access cover then begin securing wires according to the wiring diagram in figure 8 See Figures 6 amp 7 Figure 4 Figure 7 Figure 6 13 Replace access cover 14 Group wires together and tuck in wire clip on right side of box See Figure 9 WIRING OPTION 1 ON
9. ity for local disposal or recycling requirements According to the EPA s Universal Waste Rule these types of lamps may be disposed of into household waste After replacing lamp make sure a new Lamp Replacement Label supplied with lamp replacement is applied to the housing and dated with the date of installation Replace wire tie or locking mechanism to latch VI TROUBLESHOOTING GUIDE 1 2 If unit does not light up replace bulb If unit still does not light up after replacing bulb replace ballast Vil REPLACEMENT PARTS LIST Lamp Length LAMP BALLAST omg Field Controls Part Number Field Controls Part Number 46965401 46365606 46965402 46365606 46365403 46365506 For replacement parts contact your local heating service company Any questions please contact Field Controls at A S Phone 252 522 3031 Fax 252 522 0214 Email sales fieldcontrols com WARNING Never expose eyes or skin to UVC light from any source Looking directly at the UVC light may cause permanent eye damage or blindness Never operate the UV Aire Air Purifying System out of the plenum Avoid touching the glass portion of the lamp with your hands Page 7 VIII FLEX DUCT INSTALLATION For installations on duct systems with a metallic main duct and flex duct branches follow the instructions in figure 15 GALVANIZED SUPPLY DUCT FLEX DUCT GALVANIZED BUGTPIRE BRANCH DUCT ATTACHMENTS A DUCT B EXT
10. ols L L C makes no warranty of any kind in regard to any other manufacturer s products distributed by Field Controls L L C Field Controls L L C will pass on all warranties made by the manufacturer and where possible will expedite the claim on behalf of the customer but ultimately responsibility for disposition of the warranty claim lies with the manufacturer The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL FIELDCONTROLS SOLUTIONS FOR THE GREAT INDOORS P N 46427300 Rev E 05 04
Download Pdf Manuals
Related Search
Related Contents
1 república federativa do brasil ministério da MICROWAVE OVEN USER MANUAL - Canadian Appliance Source Samsung CR-1148F Sanyo KH2442 User's Manual FinePix S5000 110920 Manuel d`utilisation AG Manual Fr-Final1 Installation & User Manual V2.02 Commutative Diagrams with XY-pic I. Kernel Copyright © All rights reserved.