Home
        Enerco HS35LP Electric Heater User Manual
         Contents
1.  Gas Fired Infra Red Portable Construction Heater G  Operating Instructions and Owner s Manual          Magnetic Portion               Tip Over  Switch    Thermocouple    Tip Over    Adaptor Switch  Leads  Leads          Heater Bottom       Figure 4    Tip Over Switch Arrangement    NOTE  The purpose of the tip over Switch is to stop the flow of  gas when heater is accidentally knocked over  When and if the    heater is knocked over  simply stand heater up     REPLACEMENT PARTS LIST       REF           ITEM  DESCRIPTION          Tonada 00333 iiaa CONT M N SS PORT 3 8MPXI 4MP  T ET 02455            BURNR LTFR PORTABLES D 1096   3 axes 05455           ORIFICE BURNER  55 DRILL   Ae dine 09352  isiy THERMOCOUPLE ASSY 18   Dieibencteec 09357  s TIP OVER SWITCH 6  LEAD PORT   63 52  CORETANE AR JUNCTION BLK ADPTR KIT TIPSW  TAER 11663 iate  REC L P 21    WC OUT   EE CR705           IGNITOR  MODEL 35   ae ae CR735           PIEZO  MODEL 35   10  es CR710           WHEEL  MODEL 35   Tec ems CR720           AXLE  MODEL 35   T2 ctis CR715 42  AXLE BRACKETS  MODEL 35   13  eiie CR7255 xx HANDLE   jm CR730         WHEEL LOC   15 istis 70722 4  MAIN FRAME LOWER ASSEMBLY          Enerco Group  Inc    Gas Fired Infra Red Portable Construction Heater  6  Operating Instructions and Owner s Manual             Gas Fired Infra Red Portable Construction Heater   Model  35LP             IF SERVICE IS REQUIRED  PLEASE DO NOT RETURN THIS APPLIANCE TO YOUR STORE    For information regarding service  
2.  MODEL NO  BTU HR RATING NORMAL OPERATING CLEARANCES TO  TYPE GAS POSTION COMBUSTIBLES  NATURAL LP  amp  NG TOP SIDES BACK FRONT  35LP 35 000  VERTICAL 40  40  o    54    Tank size and tank temperature can directly affect BTU output       CONTENTS   Installation Instructions              sss 3  LOCATION MD                          3  ele um     3  Operating Instructions                   esesesceeeeeeeneeneeneneene 4  Lighting and Shut Down             ssssss 4  Maintenance Instructions               sss 5  Replacement Parts List             ssssssssseeens 6  Service and Parts Ordering Information n s    8        iN FOR YOUR SAFETY    Do not use this heater in a space where    gasoline or other liquids having flammable  vapors are stored or used        The heater is designed and approved for use as a construction  heater under ANSI Z83 7   CGA 2 14   2000    We cannot anticipate every use which may be made of our  heaters  CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF  YOU HAVE QUESTIONS ABOUT APPLICATIONS     Other standards govern the use of fuel gases and heat producing  products in specific applications  Your local authority can advise  you about these     This appliance is intended to be used primarily for the heating of  buildings under construction  alteration or repair     THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING     WARNING    Combustion by products produced when using this product contain  carbon monoxide  a chemical known to the State of California t
3.  in the vertical position and is secured with the screws  provided  see Fig  4   DO NOT operate this heater with the  LP gas supply cylinder in any other than the upright  position     LOCATION    Although this heater incorporates a  tip over  switch  the heater  and LP Gas supply cylinder must be located on a hard  flat  level  surface to minimize the risk of accidental tipping  The LP Gas  supply cylinder should be adequately restrained to prevent  accidental tipping  DO NOT OPERATE this heater with the  supply cylinder in any other than the upright position     This appliance must be installed only in locations where the  potential for physical damage to the appliance  i e   due to  physical contact  is reduced to a minimum     The installer must inform the owner operator of this appliance  that precautions must be taken to protect the appliance from  physical damage     This appliance produces radiant heat  Therefore  it must be  located at least six feet away from any LP Gas container and  must not be directed toward any LP Gas container within 20 feet     The heater must be installed in a location such that it will not be  exposed directly to water spray  rain  and or dripping water     Use of this heater in a draft windy area may decrease its  efficiency  If possible  operate the unit in a draft free area or  turn the face of the heater away from the draft     PIPING     For Model 35LP   for use with LP Gas     This model may be connected to a self contained LP Gas sup
4. 5   216 881 5500 04 04 Revision L1  18675    SPECIFICATIONS    MODEL NO                  35LP  35LP   GAS  TY PE pestes LP Gas   MAX  INLET   PRESSURE    275  W C    MIN  INLET   PRESSURE            275  W C    MANIFOLD   PRESSURE            25 5  W C     Do not exceed the gas supply pressures shown on rating plate  for Model 35LP  The maximum inlet gas supply pressure and the  minimum inlet gas supply pressure  for purposes of input  adjustment  for LP Gas are shown as follows     A WARNING    DO NOT EXCEED 27 5    W C   1 psi  INLET  PRESSURE TO HEATER           VENTILATION    A WARNING    THIS APPLIANCE IS UNVENTED AND MUST BE  USED ONLY IN A WELL VENTILATED AREA        The flow of combustion and ventilation air must not be  obstructed  DO NOT use in a tightly enclosed area  Any  combustion process requires and consumes oxygen  and may  produce carbon monoxide  This heater must be operated with  adequate ventilation  Two openings directly to the outdoors must  be provided  one low and one high  preferably on opposite sides  of the area to be heated  Each of these openings must provide at  least three square inches of combustion air intake area and  exhaust outlet area for every 1000 BTUs per hour of heater input  rate in order to complete the combustion ventilation process   Provide additional ventilation for any additional fuel burning  appliances and or additional occupants     CLEARANCE  Minimum clearances to combustible materials                                        
5. OPERATING INSTRUCTIONS AND OWNER S MANUAL  MR  HEATER   READ INSTRUCTIONS CAREFULLY  Read and   HEATSTAR       follow all instructions  Place instructions in a  safe place for future reference  Do not allow  MH35LP anyone who has not read these instructions to HS35LP  assemble  light  adjust or operate the heater                     GAS FIRED INFRA RED  PORTABLE CONSTRUCTION HEATER    DO NOT LEAVE HEATER UNATTENDED OR IN OPERATION WHILE SLEEPING    CYLINDER NOT INCLUDED    A GENERAL HAZARD WARNING     FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER  CAN RESULT IN DEATH  SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM  HAZARDS OF FIRE  EXPLOSION  BURN  ASPHYXIATION  CARBON MONOXIDE POISONING  AND OR  ELECTRICAL SHOCK     ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR  SERVICE THIS HEATER     IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS INSTRUCTION MANUALS  LABELS     ETC   CONTACT THE MANUFACTURER       N WARNING     FIRE  BURN  INHALATION AND EXPLOSION HAZARD  KEEP SOLID COMBUSTIBLES SUCH AS  BUILDING MATERIALS  PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS  RECOMMENDED BY THE INSTRUCTIONS  NEVER USE THE HEATER IN SPACES WHICH DO OR MAY  CONTAIN VOLATILE OR AIRBORNE COMPUSTIBLES OR PRODUCTS SUCH AS GASOLINE  SOLVENTS   PAINT THINNER  DUST PARTICLES OR UNKNOWN CHEMICALS        A WARNING  NOT FOR HOME OR RECREATIONAL VEHICLE USE    ENERCO GROUP  INC   4560 W  160TH ST   CLEVELAND  OHIO 4413
6. ak     2  Use only the fuel intended for this appliance  Check the  appliance rating plate for the correct fuel information     3  Turn off the main gas supply to the appliance  Wait five  minutes     4  Turn on the main gas supply     5a  Depress and turn Control Knob counterclockwise to   Pilot  position and hold for 1 2 minutes  This may take  longer to purge air from the supply hose depending on  the length of the hose being used     Depress red spark ignition button to light pilot flame   repeat until pilot lights  and continue to hold Control  Knob at  Pilot  positionfor 30 60 seconds to enable  Pilot Light Safety System     Fully turn Control Knob to  Hi  position to light burner  or       5b  With a lighted match held to the burner face  depress  and hold the reset button  After the burner ignites   hold the reset button depressed for about one minute  or until the burner stays lit when the reset button is  released  DO NOT light the gas at the burner  orifice  DO NOT face heater when attempting to  light  Always stand to the side of the unit when  lighting     NOTE  In cases where long runs of gas supply lines have been  installed ahead of the appliance  it may be necessary to bleed  trapped air out of the supply lines before lighting the burner   New installations generally require bleeding of supply lines  Wait  a minimum of five minutes after bleeding the supply lines before  attempting to light the heater     6  IMPORTANT  DO NOT attempt to adjust the main  burne
7. and Owner s Manual    
8. ections after leak  testing     A WARNING    NEVER USE A FLAME FOR GAS LEAK TESTING        OPERATING INSTRUCTIONS    WARNING  IF YOU DO NOT FOLLOW  THESE INSTRUCTION EXACTLY  A FIRE  OREXPLOSION MAY RESULT CAUSING  PROPERTY DAMAGE  PERSONAL INJURY   OR LOSS OF LIFE     CAUTION    THIS APPLIANCE IS HOT DURING  NORMAL OPERATION  AVOID  PHYSICAL CONTACT           CAUTION  DO NOT PLACE CLOTHING OR    OTHER COMBUSTIBLE MATERIALS  ON THIS APPLIANCE        DO NOT operate this heater if any part has been under  water  Call a qualified service technician to inspect the  appliance and to replace any part of the control system or gas  control valve which has been under water     This appliance must be installed and operated only in locations  where the potential for physical damage to the appliance is  reduced to a minimum  The owner operator of this appliance  must ensure that precautions are taken to protect the appliance  from physical damage     LIGHTING AND SHUT DOWN  Lighting the Heater     1  Before attempting to light the heater  smell all around  the heater area for gas  Be sure to smell next to the  floor because LP Gas is heavier than air and will settle  on the floor  Turn on the gas supply to the appliance  and check all fittings and connections for gas leaks  using a mild soap and water solution  NEVER use a  match to check for gas leaks  Should a gas leak occur   shut off the gas supply to the appliance immediately   Wait a minimum of five minutes before repairing the  le
9. o  cause cancer and birth defects  or other reproductive harm         Enerco Group  Inc    Gas Fired Infra Red Portable Construction Heater  2  Operating Instructions and Owner s Manual    GENERAL INFORMATION    A  Your Enerco Technical Products portable gas fired infra red  heater comes fully assembled and is tested at the factory for  proper gas and input as stated on the nameplate     B  Each heater is equipped with a 10096 safety shutoff  push  button valve which will automatically stop the flow of gas in  the event the heater fails to operate for any reason  A tip  over switch and an excess flow check are also standard on  the model 35LP     C  Before proceeding with this installation  be sure to inspect  for damages  The freight company must be notified of any  damages and request that an inspection be made  Enerco  Technical Products will send replacements for damaged  parts only after receiving a signed inspection report to  prove the liability of the freight company     FOR SAFE OPERATION    A  READ THESE INSTRUCTIONS CAREFULLY  Read and  adhere to these instructions  DO NOT allow anyone  who has not read these instructions to assemble  light   adjust or operate this heater     B  LP Gas IS HIGHLY FLAMMABLE  In the event of a leak  LP   Gas will accumulate and the possibility of a fire is present   LP Gas is scented and its strong odor is readily detectable   Never strike a match  bring any flame or create an electric  spark in an enclosure when you smell LP Gas  Ven
10. ontrols  etc  furnished by Enerco Group  Inc  will carry a one  1  year  warranty on the applicable warranties of the suppliers     The sole responsibility of Enerco Group  Inc  under this warranty shall be to replace or repair  any part for which a written claim is made to Enerco Technical Products within the time  limit of this warranty which is returned upon request to Enerco Group  Inc    F O B   Cleveland  Ohio   or F O B  any Enerco Technical Products authorized service facility and  which is proved to be defective upon inspection by Enerco Technical Products      This warranty shall not apply to any part or product which has been subjected to misuse or  neglect  damaged by accident  or rendered defective by reason of improper installation   THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES  EXPRESSED OR  IMPLIED  and of any other responsibility of Enerco Technical Products for parts or products  sold by Enerco Technical Products   including consequential or special damages           Enerco Group  Inc  reserves the right to make changes at any time  without notice or  obligation  in colors  specifications  accessories  materials and models           ENERCO GROUP  INC   4560 W  160TH ST   CLEVELAND  OHIO 44135   216 881 5500  Enerco and Mr  Heater are registered trademarks of Enerco Group  Inc     ANSI Z83 7 CGA 2 14 2000    2004  Enerco Group  Inc  All rights reserved    Enerco Group  Inc    Gas Fired Infra Red Portable Construction Heater Operating Instructions 
11. please call our Toll Free  Number  1 800 251 0001     Our office hours are 8 30 AM to 5 00 PM  Eastern Time Zone   Monday through Friday    Please include the model number  date of purchase and  description of problem in all communication        Enerco Group  Inc    Gas Fired Infra Red Portable Construction Heater  7  Operating Instructions and Owner s Manual       OPERATING INSTRUCTIONS AND OWNER S MANUAL       MR  HEATER READ INSTRUCTIONS CAREFULLY  Read and HEATSTAR    follow all instructions  Place instructions in a  safe place for future reference  Do not allow          MH35LP anyone who has not read these instructions to HS35LP  assemble  light  adjust or operate the heater        WARNING     USE ONLY MANUFACTURER S REPLACEMENT PARTS  USE OF ANY OTHER PARTS  COULD CAUSE INJURY OR DEATH  REPLACEMENT PARTS ARE ONLY AVAILABLE  DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE  AGENCY        PARTS ORDERING INFORMATION     PURCHASING  Accessories may be purchased at any Mr  Heater  HeatStar local  dealer or direct from the factory   FOR INFORMATION REGARDING SERVICE   Please call Toll Free 800 251 0001   www enerco mrheater com   Our office hours are 8 30 AM   5 00 PM  EST  Monday through Friday    Please include the model number  date of purchase  and description of problem in  all communication        WARRANTY    MR  HEATER warrants that Infra Red Heaters manufactured and sold will be free from  defects in material and workmanship     Parts assemblies  c
12. ply  system using the hose and regulator assembly supplied with the  appliance  OR  it may be connected to a permanently installed  LP Gas supply system     If connected to a self contained LP Gas supply system  the hose  assembly must be inspected prior to each use of the heater  If it  is evident that there is excessive abrasion or wear  or the hose is  cut  it must be replaced prior to the heater being put into  operation     If connected to a self contained LP Gas supply system  the  cylinder must have no less than a minimum capacity of 20  pounds and no more than a maximum capacity of 100 pounds of  LP Gas  DO NOT connect this appliance to a cylinder having less  than a nominal 20 pound capacity of LP Gas  DO NOT connect  this appliance to more than one  1  100 pound cylinder     AN WARNING    NEVER USE A FORK LIFT TRUCK TYPE  CYLINDER        Enerco Group  Inc    Gas Fired Infra Red Portable Construction Heater  3  Operating Instructions and Owner s Manual    The connection of Model 35LP to an LP Gas cylinder must be  made in a well ventilated area using the regulator and hose  assembly supplied with the appliance  DO NOT attempt to adjust  this regulator  It has been preset at the factory to provide safe  and proper operation of the appliance  Use a 7 8  open end  wrench to connect the POL fitting  supplied with the LP  regulator  to the LP Gas cylinder  Turn the POL nut in a counter   clockwise direction  left hand thread  until tight  DO NOT use  pipe compound on POL 
13. r input using the main gas supply valve  for this  may cause the thermocouple to shut down the burner     Enerco Group  Inc    Gas Fired Infra Red Portable Construction Heater  4  Operating Instructions and Owner s Manual    Shut down instructions   To turn the heater OFF    1  Close the LP Gas supply cylinder valve    2  Observe the burner until flame is extinguished   3  Listen for closure of the safety valve   4    IMPORTANT  DO NOT re open the LP Gas supply  cylinder valve before the safety valve closes     MAINTENANCE INSTRUCTIONS    This heater  including hose and regulator assembly  must be  inspected before each use  If the hose for Model 35LP shows  evidence of excessive abrasion or wear  or if the hose is cut  it  must be replaced prior to the heater being put into operation   The replacement hose assembly shall be that specified by the  manufacturer  See the parts list     The appliance area must be kept free and clear of combustible  materials  gasoline and other flammable vapors and liquids at all  times     The flow of combustion and ventilation air must not be  obstructed     Cleaning the heater     Periodically  the heater must be cleaned of all dirt and dust  particles      iN DANGER  DO NOT ATTEMPT TO CLEAN THE HEATER    WHILE IT IS OPERATING OR WHILE IT IS  STILL HOT     e Turn the heater off and wait until it has completely cooled   at least 20 minutes  before cleaning     e Clean the outside of the heater using a damp cloth  DO  NOT clean the heater by sp
14. raying water on it  Wipe the  outside of the heater off with a dry cloth after cleaning     e Clean the inside of the heater using compressed air  Blow  air back and forth along the entire burner face until all dust  has been dislodged from the surface of the reverberator and  grid screen  Blow through venturi from the control end of  the heater       Clean the orifice of each burner with a  55 drill bit   for LP Gas      e Clean the thermocouple lead     DO NOT operate this heater if any part has been under  water  Call a qualified service person to inspect the appliance  and to replace any part of the control system or gas control valve  which has been under water     This heater must be inspected at least annually by a qualified  service person           TROUBLESHOOTING INFORMATION    Model 35LP     If burner lights  but goes out when button is released   CHECK    Loose wires on tipover switch   see Fig  4   e Loose lead wire and repair wires if necessary       Loose thermocouple and tighten if necessary   Make sure T C is located correctly between the  reverberator and grid       Defective thermocouple  Replace if necessary   e Defective control  Replace if necessary     e Defective tip over switch  Replace if necessary           Cylinder  Gas Valve  Burner Face    Propane    Reflector Gas  Cylinder    Regulator    Valve       Hose    NOTE  WHEN LIGHTING BURNER WITH A MATCH OR TAPER  LIGHT AT  BOTTOM OF SCREEN   NOT AT ORIFICE              Figure 3    Enerco Group  Inc   
15. threads     The heater must be located at least six feet away from any LP   Gas cylinder and must not be directed toward any LP Gas  cylinder within 20 feet  If more than one heater is used  they and  the supply cylinders must be separated by at least 20 feet     The gas supply must be turned off at the LP Gas supply cylinder  when the heater is not in use     When the heater is to be stored indoors  the connection  between the LP Gas supply cylinder and the heater must be  disconnected and the cylinder removed from the heater and  stored in accordance with Chapter 5 of the Standard for the  Storage and Handling of Liquefied Petroleum Gases  ANSI NF PA  58  U S    OR CAN CGA B149 2  Canada      If connected to a permanently installed LP Gas supply system   the system requires the use of a two stage gas regulator  assembly which is normally provided by your LP Gas dealer as  part of the LP Gas supply system  Consult with your local LP Gas  dealer for details concerning proper equipment and installation     Piping must be clean and free from scale or burr     Before attempting to ignite the appliance  all gas fittings and  connections must be thoroughly checked for gas leaks  Apply a  small amount of a mild soap and water solution to all fittings  and connections and observe for escaping bubbles  If any leaks  are detected  shut off the gas supply to the appliance  immediately  Wait a minimum of five minutes  repair the leak s   and retest for leakage  Dry all fittings and conn
16. tilate the  area thoroughly  move the heater outside  and correct the  source of the leak before attempting to light any appliance     C  Always operate the heater with the LP Gas cylinder in an  upright position on a level non combustible surface  NEVER  PLACE THE CYLINDER ON ITS SIDE WHEN OPERATING  THE HEATER     D  DO NOT attempt to operate the heater with any gas  other than that indicated on the heater nameplate     INSTALLATION INSTRUCTIONS  GENERAL    For the U S  and or Canada  the installation of this appliance  must comply with local and or Provincial codes or  in the  absence of these codes     e With the  U S   National Fuel Gas Code  ANSI Z223 1    Latest Edition  AND with the  U S   Standard for the Storage  and Handling of Liquified Petroleum Gases  ANSI NFPA 58   OR    e With the current  Canadian  CAN CGA B149 1 AND B149 2  INSTALLATION CODES     This heater  including hose and regulator assembly  must be  inspected before each use and at least annually by a qualified  service person  If the hose for Model 35LP shows evidence of  excessive abrasion or wear  or if the hose is cut  it must be  replaced prior to the heater being put into operation  The  replacement hose assembly shall be that specified by the  manufacturer  See the parts list        The minimum ambient temperature rating for this heater is 20  degrees F     This heater incorporates a  Tip Over  switch which automatically  shuts off the burner in the event of tipping  Ensure that this  Switch is
    