Home

Desa HDR18NT Gas Heater User Manual

image

Contents

1. 121255 01A www desatech com 11 INSTALLATION Continued IMPORTANT Install an equipment shutoff valve in an accessible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male NPT threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Pressure Regulator FS A 5 3 8 NPT Regulator Pipe Bracket Nipple Heater Ground Cabinet Joint Union S Tee Joint Equipment 2 Reducer i Shutoff 8 Bushing to g gt Valve D VS NFI j I is a 1 8 NPT 19 From Gas Plug Tap Min Meter 7 W C ES to 10 5 W C e Tee Pipe Cap Pressure Joint Nipple Propane LP From External Sediment Trap Regulator 11 W C to 14 W C Pressure Refer to connector s a0 instructions gt Flexline y RL TM See j illustration 3 8 NPT 1 2 ES above for Flare 90 Elbow detail Connection Using Flexline Figure 15 Gas Connection ACSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable al ternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer See Acces sories page 21 Install sediment trap in supply line as shown in Figure 15 Locat
2. V lvula de cierre del equipo Figura 18 Revision de las uniones de gas para propano o gas LP 121255 01A www desatech com 15 FUNCIONAMIENTO POR SU SEGURIDAD LEA ESTO ANTES DE ENCENDER EL CALENTADOR A ADVERTENCIA si no sigue estas instrucciones exactamen te se puede producir unincendio o una explosi n que ocasionen da os a la propiedad lesiones personales o la muerte A Este aparato tiene un piloto que debe ser encendido manualmente Cuando encienda el piloto siga estas instruc ciones al pie de la letra ANTES DE ENCENDERLO compruebe que alrededor del aparato no huela a gas Aseg rese de oler tambi n cerca del piso ya que algunos gases son m s pesados que el aire y se asientan cerca del piso QU HACER SI PERCIBE OLOR A GAS e No intente encender ning n aparato e No toque ning n interruptor el ctrico no use ning n tel fono en el edificio e Llame inmediatamente a su provee dor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas Si no puede localizar al proveedor de gas llame al departamento de bomberos Utilice nicamente la mano para pre sionar o girar la perilla de control de gas Nunca utilice herramientas Si no puede presionar o girar la perilla manualmente no intente repararla llame a un t cnico de servicio capa citado Forzarla o tratar de repararla pueden producir un incendi
3. Regulador de gas natural Soporte del regulador Conjunto de herrajes Abrazadera de cable Protector del piloto E ee No es una pieza que se pueda reemplazar en el sitio oe o a e l A E ERRE 5 n 5 BS ma 121255 01A www desatech com 27 PIEZAS MODELOS CON CONJUNTO DE QUEMADOR LCR16PT LCR18NT LCR26PT LCR30NT HDR16PT HDR18NT HDR26PT HDR30NT Esta lista contiene las piezas reemplazables utilizadas en el calentador Al hacer un pedido de piezas siga las instrucciones provistas en Piezas de repuesto en la pagina 29 de este manual Conjunto de quemador Conjunto de quemador LCR16PT LCR18NT HDR16PT y LCR26PT LCR30NT HDR26PT y HDR18NT HDR30NT iki Rib DIAS N DE PASS N PARTE DESCRIPCI N Xi X X SCANT 1 120630 02 Piloto con ODS LP E 120630 03 Piloto con ODS NG Torao at 1 1 120791 01 Electrodo del encendedor pocos a 1 2 120790 01 Termopar 0 1 2 099387 03 Tubo de piloto E 1 099387 11 Tubo de piloto Goo 1 3 104818 03 Tubo de salida v lvula a quemador 1 104818 04 Tubo de salida v lvula a quemador 1 4 099218 08 Quemador DN g 099218 09 Quemador poo 4 5 099056 24 Inyector placa Ao C i jej pe 12 099056 25__Inyector placa Ao C pep oie 1 2 6 099056 01 Inyector placa B C 20 2 4 099056 02 Inyector placa B dor o 4 28 www desatech com 121255 01A PIEZAS DE REPUESTO Nota use s lo piezas
4. combusti n y ventilaci n para conocer el tama o requerido de las rejillas o conductos de ventilaci n IMPORTANTE no haga aberturas de entrada y salida de aire hacia el tico si ste tiene ven tilaci n el ctrica controlada por un termostato El aire caliente que entre al tico activar la ventilaci n el ctrica ES Salida de aire Atico ventilado a 1 Salida de aire Al tico vna Al espacio debajo del piso Entrada de aire ap amp a Espacio ventilado debajo del piso Entrada de aire Figura 3 Aire del exterior para ventilacion 121255 01A www desatech com T INSTALACION AVISO este calentador esta dise ado para utilizarse como calefacci n adicional Use este calentador junto con su sistema de calefacci n principal Noins tale este calentador como fuente de calefacci n principal Sitiene un sistema de calefacci n cen tral puede activar el ventilador de circulaci n del sistema mien tras utiliza el calentador Esto ayudar a que el calor circule en toda la casa En caso de que se produzca una interrupci n de la energ a el ctrica puede usar este calentador como su fuente de calefacci n principal AX ADVERTENCIA una perso na de servicio capacitada debe instalar el calentador Sigatodos los c digos locales VERIFIQUE EL TIPO DE GAS Use nicamente el tipo
5. del reloj hasta la posici n PILOT piloto AX PRECAUCI N no intente ajustar los niveles de calefac ci n por medio de la v lvula de cierre del equipo Perilla de pe paon Bot n del D pence A Figura 19 Perilla de control en la posici n OFF apagado Termopar Electrodo del encendedor Quemador del piloto Figura 20 Piloto PARA SELECCIONAR EL NIVEL DE CALEFACCI N ADVERTENCIA cuando haga funcionar el calentador coloque la perilla de control en las posiciones de bloqueo LOW MED o HI BAJO MEDIO o ALTO Nunca coloque la perilla de control entre posiciones de bloqueo Se pueden producir una combusti n deficiente y niveles m s altos de mon xido de carbono Ay PRECAUCI N no intente ajustar los niveles de calefac ci n por medio de la v lvula de cierre del equipo Gire la perilla de control del termostato en sentido contrario al de las manecillas del reloj hacia el nivel de calefacci n deseado El quemador principal deber encenderse Coloque la perilla de control en cualquier nivel de calefacci n entre 1 y 5 consulte la figura 21 Quemadores 2 Figura 21 Patrones del quemador Perilla de control 121255 01A www desatech com 17 FUNCIONAMIENTO Continuaci n C MO CERRAR EL E SUMINISTRO DE GAS g AL APARATO 1 Gire la perilla de control en direcci n de la manecillas del reloj hasta
6. en el orificio Golpee suavemente el anclaje para introducirlo en la pared 4 Para paredes delgadas de 1 3 cm 1 2 o menos inserte la llave roja en el anclaje de pared Empuje la llave roja para que abra las alas de anclaje IMPORTANTE no golpee la llave con un martillo Para paredes gruesas de m s de 1 3 cm 1 2 de ancho O paredes s lidas no abra las alas 5 Coloque el soporte de montaje en la pared Alinee el ltimo orificio de cada extremo del soporte con los anclajes de pared 6 Inserte los tornillos de montaje en el soporte y en los anclajes de pared 7 Apriete los tornillos hasta que el soporte de montaje est asegurado firmemente a la pared Pa TEN i Figura 9 C mo Figura 10 C mo abrir doblar el anclaje las alas del anclaje para paredes delgadas 3 Colocaci n del calentador en el soporte de montaje 1 2 Lengueta saliente Localice las dos ranuras horizontales en el panel posterior del calentador Coloque el calentador en el soporte de montaje Deslice las ranuras horizontales hacia las leng etas salientes del soporte de montaje Ranuras horizontales Soporte de montaje fijado a la pared Figura 11 Montaje del calentador en el soporte de montaje Instalaci n de los tornillos de montaje inferiores 1 2 3 4 Calentador Localice los dos orificios de montaje infe riores Estos orificios se encuentran cerca de la parte inferior del pan
7. tains and or generates chemicals known to the State of California to cause cancer or birth defects or other reproductive harm IMPORTANT Read this owner s manual carefully and completely before trying to assemble operate or service this heater Improper use of this heater can cause serious injury or death from burns fire explosion electrical shock and carbon monoxide poisoning A DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the heater may not be working properly Get fresh air at once Have heater serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes 121255 01A SAFETY Continued Natural and Propane LP Gas Natural and Propane LP gases are odorless An odor mak ing agent is added to these gases The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this heater Keep the appliance area clear and free from combustible ma terials gasoline and other flam mable vapors and
8. volumen total del espacio 2 Multiplique el volumen del espacio por 20 para determinar la cantidad m xima de BTU h que el espacio puede admitir volumen del espacio en pies x 20 cantidad m xima de BTU h que el espacio puede admitir Ejemplo 72 49 m 2560 pies volumen del espacio x 20 51 200 BTU h m ximo que el espacio puede admitir 3 Agregue la cantidad de BTU h de todos los apa ratos que queman combustible en ese espacio Calentador sin ventilaci n BTU h Calentador de agua a gas BTU h Horno de gas BTU h Calentador de gas con ventilaci n BTU h Chimenea de gas BTU h Otros aparatos de gas BTU h Total BTU h No incluya los aparatos de gas con ventilaci n direc ta El sistema de ventilaci n directa toma el aire para combusti n del exterior y ventila hacia el exterior Ejemplo Calentador de agua agas _ 40 000 BTU h Calentador sin ventilaci n _20 000_ BTU h Total 60 000 BTU h 4 Compare la cantidad maxima de BTU h que el espacio puede admitir con la cantidad real de BTU h que se utiliza BTU h cantidad maxima que el espacio puede admitir BTU h cantidad real de BTU h que se utiliza Ejemplo 51 200 BTU h cantidad maxima que el espacio puede admitir 60 000 BTU h cantidad real de BTU h que se utiliza El espacio del ejemplo anterior es un espacio confinado ya que la cantidad real de BTU h que se utiliza es mayor que la cantidad maxima de BTU h que el espacio puede admitir Se ti
9. 16 or replace burner orifice s Burner backfiring during 1 Burner orifice s is clogged 1 Clean burner orifice s combustion or damaged see Cleaning page 16 or replace burner orifice s 2 Burner damaged 2 Replace burner 3 Gas regulator defective 3 Replace gas regulator Burner plaque s does not 1 Plaque damaged 1 Replace burner glow 2 Inlet gas pressure is too 2 Contact local natural or low propane LP gas company 3 Control knob set between 3 Turn control knob until it locked positions locks at desired setting Slight smoke or odor during initial operation il Residues from manufactur ing processes Problem will stop after a few hours of operation Heater produces a clicking ticking noise just after burner is lit or shut off i Metal expanding while heating or contracting while cooling This is normal with most heaters If noise is exces sive contact qualified ser vice person 121255 01A www desatech com 19 TROUBLESHOOTING Continued A WARNING If you smell gas e Shut off gas supply e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Fol low the gas supplier s instructions e If you cannot reach your gas supplier call the fire department IMPORTANT Operating heater where impurities in air exist may create odors Cleaning s
10. 18 Apply a noncorrosive leak de tection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operation Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 15 8 Replace front panel Equipment ES Open Shutoff Valve Closed Figure 16 Equipment Shutoff Valve Thermostat Gas Valve Y 000000000 E Equipment Shutoff Valve Figure 17 Checking Gas Joints for Natural Gas Thermostat Gas Valve Propane LP Supply Tank 6 y Y f mD ma a ya ii Z ES Equipment Shutoff Lapas denar a Valve Figure 18 Checking Gas Joints for Propane LP Gas OPERATION a FOR YOUR SAFETY READ BEFORE LIGHTING A WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor 121255 01A www desatech com 13 OPERATION Continued WHAT T
11. ADVERTENCIA pruebe to das las conexiones y tuber a de gas tanto internas como exter nas para verificar que no haya fugas despu s de la instalaci n o reparaci n Repare todas las fugas inmediatamente Ay ADVERTENCIA nunca use una llama al descubierto para buscar fugas Aplique alg n l quido no corrosivo para detectar fugas en todas las uniones La formaci n de burbujas indicar una fuga Repare todas las fugas inmediatamente A PRECAUCI N para propa no o gas LP aseg rese de que el regulador externo se haya instalado entre el suministro de propano o gas LP y el calentador Consulte las instrucciones en Conexi n al suministro de gas en la p gina 11 PRUEBAS DE PRESI N DEL SISTEMA DE TUBER A DE SUMINISTRO DE GAS Pruebas de las presiones que excedan 1 2 PSI 3 5 kPa 1 Desconecte el aparato junto con la v lvula principal de gas del aparato v lvula de control y la v lvula de cierre del equipo del sistema de tuber a de suministro de gas Las presiones que excedan 1 2 PSI da ar n el regulador del calentador 2 Coloque una tapa en el extremo abierto del tubo de gas donde estaba conectada la v lvula de cierre del equipo 3 Regule la presi n del sistema de tuber a de suministro ya sea abriendo la v lvula del tanque de suministro de propano o gas LP en caso que utilice este tipo de gas o bien abriendo la v lvula principal de gas que se localiza en el medidor de ga
12. AX WARNING When running heater set control knob at LOW MED or HI locked positions Never set control knob between locked positions Poor combus tion and higher levels of carbon monoxide may result A CAUTION Do not try to ad just heating levels by using the equipment shutoff valve Turn thermostat control knob counterclock wise to the desired heating level The main burner should light Set control knob to any heat level between 1 and 5 see Figure 21 Control Knob Figure 21 Burner Patterns TO TURN OFF GAS TO APPLIANCE Turn control knob clockwise to the OFF position 2 Turn off all electric power to the appliance if service is to be performed 3 Close equipment shutoff valve see Figure 16 page 13 Burners THERMOSTAT CONTROL OPERATION The thermostatic control used on these models differs from standard thermostats Standard thermostats simply turn on and off the burner The thermostat used on this heater senses the room temperature At times the room may exceed the set temperature If so the burner will shut off The burner will cycle back on when room temperature drops below the set temperature The control knob can be set to any heat level between 1 and 5 All plaques will turn off and on Note The thermostat sensing bulb mea sures the temperature of air near the heater cabinet This may not always agree with room temperature depending on housing construction installat
13. PILOT IGN piloto enc Pre al presionar el bot n del sione completamente la pe encendedor rilla de control presionando simult neamente la perilla del encendedor 4 Presencia de aire en las 4 Mantenga la perilla de control l neas de gas cuando se presionada Repita la opera instalaron ci n de encendido hasta que se expulse el aire 5 Se agot el suministro de 5 Comun quese con la compa a gas propano o gas LP local de propano o gas LP 6 El piloto con ODS est 6 Limpie el piloto con ODS tapado consulte Limpieza p gina 20 o cambie el conjunto de piloto y ODS 7 La posici n del regulador de 7 Reemplace el regulador de gas no es la correcta gas 121255 01A www desatech com 21 SOLUCI N DE PROBLEMAS Continuaci n PROBLEMA OBSERVADO CAUSA POSIBLE REMEDIO En las ventanas se forma humedad o se condensa el agua 1 Hay residuos provenientes de procesos de fabricaci n 1 Consulte los requisitos de Aire para combusti n y ventilaci n p gina 5 El piloto con ODS se encien de pero la llama se extingue cuando se suelta la perilla de control La perilla de control no est presionada completamente La perilla de control no se presion durante el tiempo suficiente La v lvula de cierre del equipo no est totalmente abierta La conexi n del termopar est floja en la v lvula de control La llama del piloto no est tocando el termopar lo que
14. amount of air to mix with the gas This pro vides a clean burning flame Keep these holes clear of dust dirt and lint Clean these air inlet holes prior to each heating season Blocked air holes will create soot We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could dam age the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot for dust and dirt 3 Blow air through the ports slots and holes in the burner 4 Never insert objects into the pilot tube Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet about two inches from where the pilot flame comes out of the pilot assembly see Figure 26 With the unit off lightly blow air through the air inlet You may blow through a drinking straw if compressed air is not available Pilot Air Inlet Figure 26 Pilot Air Inlet CABINET Air Passa
15. correcto de gas na tural o propano o gas LP Si el suministro de gas no es del tipo correcto no instale el Calentador Llame al distribuidor a quien le compr el calentador para adquirir el tipo de calentador correcto ADVERTENCIA este aparato est equipado ya sea para gas natural o para propano gas LP pero no para ambos El tipo de gas se indica en la placa de cla sificaci n No se permite hacer conversiones en campo 8 www desatech com ART CULOS DE INSTALACI N Antes de instalar el calentador aseg rese de tener los art culos que se indican a con tinuaci n e Para propano o gas LP un regulador ex terno proporcionado por el instalador tuber a consulte los c digos locales sellador resistente al propano o gas LP v lvula de cierre del equipo uni n de terminal con conexi n a tierra trampa de sedimentos e uni n T llave para tuber a para gas natural conexi n para medidor de prueba Una v lvula de cierre de equipo con dise o certificado por la CSA con rosca tipo NPT de 1 8 de pulgada es una alternativa aceptable como conexi n para medidor de prueba La v lvula opcional de cierre de equipo con dise o certificado por la CSA la puede adquirir con su distribuidor Consulte Accesorios p gina 25 UBICACI N DEL CALENTADOR Este calentador est dise ado para montarse en la pared ADVERTENCIA mantenga las distancias m nimas que se muestran en l
16. follow the instructions listed under Replacement Parts on page 25 of this manual Burner Assembly Burner Assembly LCR16PT LCR18NT HDR16PT and LCR26PT LCR30NT HDR26PT and HDR18NT HDR30NT NO PART NO DESCRIPTION 1 120630 02 ODS Pilot LP 120630 03 ODS Pilot NG 1 1 120791 01 Ignitor Electrode 1 2 120790 01 Thermocouple 2 099387 03 Pilot Tubing 099387 11 Pilot Tubing E 3 104818 03 Outlet Tubing Valve to Burner 104818 04 Outlet Tubing Valve to Burner 4 099218 08 Burner 099218 09 Burner 5 099056 24 Injector Plaque A or C 099056 25 Injector Plaque A or C 6 099056 01 Injector Plaque B 099056 02 Injector Plaque B 24 www desatech com 121255 01A REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heating Products Technical Ser vice Department at 1 866 672 6040 When calling DESA Heating Products have ready your name your address model and serial numbers of your heater how heater was malfunctioning e type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original
17. is higher heater regulator damage could occur A CAUTION For propane LP gas never connect heater di rectly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator between the heater and propane LP supply For propane LP gas the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of water If you do not reduce incom ing gas pressure heater regulator damage could occur Install the external regulator with the vent pointing down as shown in Figure 14 Pointing the vent down protects it from freezing rain or sleet A CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of large enough diameter to allow proper gas volume to heater If pipe is too small undue loss of volume will occur Typical Inlet Pipe Diameters 16 18 000 Btu hr models 3 8 or greater 26 30 000 Btu hr models 1 2 or greater Installation must include equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 15 page 12 Propane LP Supply Tank External Regulator Vent Pointing Down Figure 14 External Regulator With Vent Pointing Down
18. la posici n OFF apagado 2 Si va a realizar alg n trabajo de mante nimiento desconecte el suministro de energ a el ctrica al calentador 3 Cierre la v lvula de cierre del equipo consulte la figura 16 en la p gina 15 CONTROL CON TERMOSTATO FUNCIONAMIENTO El control termost tico que se usa en estos modelos es distinto que el de los termostatos convencionales Los termostatos conven cionales simplemente encienden y apagan el quemador El termostato que se usa en este calentador detecta la temperatura de la habitaci n En ocasiones la temperatura de la habitaci n puede ser mayor que la estable cida Si esto ocurre el quemador se apagar El quemador volver a encenderse cuando la temperatura de la habitaci n disminuya por debajo de la temperatura establecida La pe rilla de control se puede colocar en cualquier nivel de calor entre 1 y 5 Todas las placas se apagar n y se encender n Nota el bulbo sensor del termostato mide la temperatura del aire cercano al gabinete del calentador Es posible que sta no concuerde con la temperatura de la habitaci n depen diendo de la construcci n de la habitaci n la ubicaci n de la instalaci n el tama o de la habitaci n las temperaturas en los exteriores etc El uso frecuente del calentador le per mitir determinar los niveles que le resulten m s c modos PROCEDIMIENTO PARA ENCENDIDO MANUAL 1 Desmonte el panel anterior consulte la figura 7 p gin
19. los tornillos de montaje en el soporte de montaje y en las vigas de pared Fijaci n a anclajes de pared este m todo le permite fijar el soporte de montaje en pa redes huecas las reas de la pared que se encuentran entre los maderos o en paredes s lidas de concreto o mamposter a Decida cu l m todo se ajusta mejor a sus necesidades Cualquiera de los dos m to dos proporcionar un apoyo seguro para el soporte de montaje C mo marcar las ubicaciones de los tornillos 1 Fije el soporte de montaje a la pared con cinta en el lugar donde estar situado Aseg rese de que el soporte de montaje est nivelado Ay ADVERTENCIA mantenga las distancias m nimas que se muestran en la figura 8 Si puede proporcione distancias m nimas mayores con respecto al piso y la pared de uni n 2 Marque la ubicaci n de los tornillos en la pared consulte la figura 8 Nota marque nicamente el ltimo orificio de cada extremo del soporte de montaje Inserte los tornillos de montaje en estos orificios solamente 3 Quite la cinta y el soporte de montaje de la pared Min 35 6 cm 14 30 4 cm E ODO a H a 12 2 A td 4 A Z Inserte los tornillos 47 6 cm 6 de montaje s loa 18 3 4 3 trav s del ltimo M n orificio de cada extremo t Piso Calentador con 3 placas Min 40 6 cm 16 35 6 cm 14 Inserte los tornillos 47 6 cm de montaje
20. nea de gas no debe ser de m s de 10 5 de agua Si la presi n de la l nea de gas es mayor se pueden producir da os al regulador del calentador PRECAUCI N para propano o gas LP nunca conecte el calen tador directamente al suministro de propano o gas LP Este ca lentador requiere un regulador externo no se incluye Instale el regulador externo entre el calentador y el suministro de propano o gas LP Para gas propano o LP el instalador debe proveer un regulador externo El regulador externo reducir la presi n del gas entrante Debe reducir la presi n del gas entrante de manera que est entre 11 y 14 de agua Si no reduce la presi n del gas entrante se pueden producir da os al regulador del calentador Instale el regulador externo con la ventila apuntando hacia abajo como se muestra en la figura 14 El apuntar la ventila hacia abajo la protege de la lluvia helada o aguanieve Ad PRECAUCI N utilice nica mente tuber a nueva de hierro negro o de acero En ciertas reas se puede usar tuber a de cobre galvanizada internamen te Consulte los c digos locales Utilice tuber a de un di metro lo suficientemente grande para permitir el paso del volumen de gas adecuado al calentador Si la tuber a es demasiado angosta se producir una p rdida inde bida de volumen Di metros usuales de tuber a de entrada 16 18 000 Btu h modelos 3 8 o mayor 26 30 000 Btu h modelos 1 2 o may
21. panels at penetrations for plumbing electri cal and gas lines and at other openings If your home meets all of these three criteria you must provide additional fresh air See Ventilation Air From Outdoors page 7 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow For Heater Location page 6 Confined and Unconfined Space The National Fuel Gas Code ANSI 2223 1 NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m per kw of the ag gregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the un confined space Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them 121255 01A www desatech com 5 AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining r
22. part s required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Heating LLC Authorized Service Center Warranty part s MUST be obtained through authorized dealers of this product and or DESA Heating LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EX PRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE TO TWO 2 YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE AND DESA HEATING LLC S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESAHEATING LLC S SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDI
23. peligroso A ADVERTENCIA no utilice un aditamento ventilador o de inter cambio de calor ni ning n otro accesorio que no est aprobado para usarse con este calentador Debido alas altas temperaturas el aparato debe situarse fuera de las rutas de paso y alejado de los muebles y cortinas No coloque ropa ni otros mate riales inflamables sobre el apa rato ni cerca del mismo Nunca coloque ning n objeto sobre el calentador La superficie del calentador alcanza temperaturas muy altas cuando ste est funcionando Mantenga a los ni os y a los adultos alejados de las superfi cies calientes para evitar quema duras o que la ropa se queme El calentador permanecer calien te durante alg n tiempo despu s de que se ha apagado Permita que la superficie se enfr e antes de tocarla Supervise cuidadosamentea los ni os peque os cuando est n en la habitaci n en la que se encuentra el calentador Aseg rese que la rejilla de res guardo est puesta antes de hacer funcionar el calentador Mantenga el rea del aparato lim pia y libre de materiales combus tibles gasolina y otros vapores y l quidos inflamables Este aparato est dise ado para usarse nicamente con el tipo de gas indicado en la placa de clasificaci n Este aparato no se puede convertir para que utilice otro tipo de gas No ponga los tanques de suministro de propano o gas LP dent
24. replacement part s either contact your nearest Parts Central or call DESA Heating Products at 1 866 672 6040 for referral information When calling DESA Heating Products have ready model number of your heater the replacement part number SERVICE PUBLICATIONS You can purchase a service manual from the address listed on the back page of this manual Send a check for 5 00 payable to DESA Heating Products PARTS CENTRAL These Parts Centrals are privately owned businesses They have agreed to support our customer s needs by providing original replacement parts and accessories Those Heater Guys 255 E Stowell Street Upland CA 91786 909 982 3011 Tool amp Equipment Co 5 Manila Ave Hamden CT 06514 1 800 397 7553 203 248 7553 Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 219 462 7441 1 888 619 7060 www portableheaterparts com sales portableheaterparts com techservice portableheaterparts com FBD 1349 Adams Street Bowling Green KY 42103 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 616 791 0505 1 800 446 1446 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 KS MO AR 816 842 3911 www washerparts com East Coast Energy 10 East Route 36 W Long Branch NJ 07764 732 870 8809 1 800 755 8809 www njplaza com ecep 21st Century 2950 Fretz Valley Perkasie P
25. toque ning n interruptor el ctrico no use ning n tel fono en el edificio e Llame inmediatamente a su proveedor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas e Si no puede localizar al proveedor de gas llame al departamento de bomberos La instalaci n y el servicio deben ser realizados por un instalador capacitado una agencia de servicio o el proveedor de gas INSTALADOR Deje este manual con el aparato CONSUMIDOR Conserve este manual para referencias futuras Para obtener m s informaci n visite www desatech com TABLA DE CONTENIDO Seguridade se ins e ES 2 C digos locale S nrram 4 D SOMPAaqUE cooocccocccoccconocconccconcnoncncnncnoncccanenonncnnne 4 Identificaci n del producto cceeeeeeeeeeereeeeee 4 Caracter sticas del prodUCtO ooooococcccnncnincccncco 5 Aire para combusti n y ventilaci n 5 Instalaci n enaena dijo taco dd einen astas 8 Funcionamiento 0 0 Inspecci n del calentador LiIMPISZA coi 20 SEGURIDAD A ADVERTENCIA la ins talaci n ajuste alteraci n servicio o mantenimiento inadecuados pueden pro vocar lesiones o da os a la propiedad Consulte este manual para conocer los procedimientos de instalaci n y operaci n correctos Para obtener asistencia o informaci n adicionales consulte a un instalador capacitado agencia de servicio o al proveedor de gas A ADVERTENCIA este
26. water Maximum 14 W C Minimum 11 W C Average Heater Weight 22 Ib 10 kg Average Shipping Weight 25 5 Ib 11 6 kg LCR26PT HDR26PT e Propane LP Gas 26 000 Btu hr e Piezo Ignition e Pressure Regulator Setting 8 W C Inlet Gas Pressure in of water Maximum 14 W C Minimum 11 W C Average Heater Weight 29 Ib 13 2 kg Average Shipping Weight 33 Ib 15 kg Note Dimensions listed are outer most points on the heater includes control knobs and grill For purposes of input adjustment ACCESSORIES Purchase these heater accessories from your local dealer If they can not supply these ac cessories either contact your nearest Parts Central see page 25 or call DESA Heating Products at 1 866 672 6040 for referral in formation You can also write to the address listed on the back page of this manual ELECTRONIC IGNITOR KIT GA435 Not Shown For all piezo ignitor models Provides easier lighting of the pilot EQUIPMENT SHUTOFF VALVE GA5010 For all models Equipment shutoff valve with 1 8 NPT tap 121255 01A www desatech com 21 PARTS CABINET BODY MODELS LCR16PT LCR18NT LCR26PT LCR30NT HDR16PT HDR18NT HDR26PT HDR30NT 1 22 www desatech com 121255 01A PARTS This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page
27. 1 2 5 cm deep 2 Fold wall anchor as shown in Figure 9 3 Insert wall anchor wings first into hole Tap anchor flush to wall 4 For thin walls 1 2 1 3 cm or less insert red key into wall anchor Push red key to pop open anchor wings IMPORTANT Do not hammer key For thick walls over 1 2 1 3 cm thick or solid walls do not pop open wings 5 Place mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall NX S A Figure 9 Folding Figure 10 Popping Anchor Open Anchor Wings For Thin Walls Placing Heater On Mounting Bracket 1 Locate two horizontal slots on back panel of heater 2 Place heater onto mounting bracket Slide horizontal slots onto stand out tabs on mounting bracket Horizontal Slots Mounting Bracket attached to wall Stand Out Tab Figure 11 Mounting Heater Onto Mounting Bracket Installing Bottom Mounting Screws 1 Locate two bottom mounting holes These holes are near bottom on back panel of heater see Figure 12 Mark screw locations on wall Remove heater from mounting bracket If installing bottom mounting screws into hollow or solid wall install wall anchors Follow steps 1 through 4 under Attaching To Wall Anchor Method If installing bottom mounting screw into wall stud d
28. 1 Vent Free Gas Heater PRODUCT FEATURES SAFETY DEVICE This heater has a pilot with an Oxygen Deple tion Sensing ODS safety shutoff system The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYSTEM This heater has a piezo ignitor This system re quires no matches batteries or other sources to light heater THERMOSTATIC HEAT CONTROL Thermostat models have a thermostat sens ing bulb and a control valve This results in the greatest heater comfort This can also result in lower gas bills 4 www desatech com 121255 01A AIR FOR COMBUSTION AND VENTILATION AX WARNING This heater shall not be installed in a confined space or unusually tight con struction unless provisions are provided for adequate combus tion and ventilation air Read the following instructions to insure proper fresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased insulation and new construction methods help reduce heat loss in homes Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burn
29. 24 shows a correct burner flame pat tern Figure 25 shows an incorrect burner flame pattern If burner flame pattern is incorrect as shown in Figure 25 e turn heater off see To Turn Off Gas to Ap pliance page 15 e see Troubleshooting page 18 Figure 24 Correct Burner Flame Pattern erg Audi Dey Figure 25 Incorrect Burner Flame Pattern CLEANING A WARNING Turn off heater and let cool before cleaning A CAUTION You must keep control areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent clean ing due to excessive lint from carpeting bedding material pet hair etc A WARNING Failure to keep the primary air opening s of the burner s clean may resultin sooting and property damage 16 www desatech com 121255 01A CLEANING Continued ODS PILOT AND BURNER Use a vacuum cleaner pressurized air or small soft bristled brush to clean BURNER PILOT AIR INLET The primary air inlet holes allow the proper
30. 25 of this manual KEY NO 1 Rw OOANON 10 11 12 13 14 15 16 17 PART NO 107673 01 107673 03 107676 01 107676 05 103476 01 103476 02 Apron 107894 12 107894 13 kk 098271 09 107896 01 107896 02 111421 01 120378 01 099415 18 099415 19 104819 02 098522 24 102394 02 103256 02 118721 02 118721 01 18 fig 20 21 22 23 119099 01 119664 01 118661 01 099038 01 PP100 101547 01 DESCRIPTION Front Panel Front Panel Front Panel Front Panel Grill Guard Grill Guard Reflector Assembly Piezo Ignitor Reflector Assembly Cabinet Back Panel 097159 04 099066 02 Mounting Bracket Ignitor Cable Heat Shield Heat Shield Snap Bushing Base Feet Gas Regulator Propane LP Gas Gas Regulator Natural Gas Regulator Bracket Inlet Tube Upper Baffle Upper Baffle Lower Baffle Thermal Limit Switch Housing Duct Strain Relief Bushing Fan Kit Snap Bushing E e PARTS AVAILABLE NOT SHOWN 100642 03 Hardware Assembly 105345 01 109121 01 Cable Tie Pilot Shield Not a field replaceable part Thermostat Gas Valve Thermostat Valve Mounting Bracket Og z 121255 01A www desatech com 23 PARTS BURNER ASSEMBLY MODELS LCR16PT LCR18NT LCR26PT LCR30NT HDR16PT HDR18NT HDR26PT HDR30NT This list contains replaceable parts used in your heater When ordering parts
31. A 18944 215 795 0400 800 325 4828 Laporte s Parts amp Service 2444 N 5th Street Hartsville SC 29550 843 332 0191 Parts Department Cans Unlimited P O Box 645 Taylor SC 29687 803 879 3009 1 800 845 5301 cuisales aol com 121255 01A www desatech com 25 WARRANTY KEEP THIS WARRANTY Model Serial No Date of Purchase Always specify model and serial numbers when communicating with the factory The only warranty applicable is our standard written warranty We make no other warranty expressed or implied LIMITED WARRANTIES FOR NEW AND FACTORY RECONDITIONED PRODUCTS New Products DESA Heating LLC warrants this heater and any parts thereof to be free of defects in materials and workmanship for two 2 years from the date of first purchase when operated and maintained in accordance with the manufacturer s instructions These warranties are extended only to the original retail purchaser when proof of purchase is provided Factory Reconditioned Heaters DESA Heating LLC warrants this factory reconditioned heater and any parts thereof to be free of defects in materials and workmanship for thirty 30 days from the date of first purchase when operated and maintained in accordance with the manufacturer s instructions These warranties are extended only to the original retail purchaser when proof of purchase is provided This warranty is extended only to the original retail purchaser This warranty covers the cost of
32. ALENTADOR EN EL PISO CON UN EQUIPO PARA PISO OPCIONAL Montaje de las patas de la base en el calentador Nota se requiere una conexi n de codo de 90 para el montaje de esta unidad y se debe instalar ANTES que las patas de la base para cumplir con las distancias m nimas consulte la figura 15 p gina 13 1 Coloque el gabinete del calentador en una mesa sobre su parte posterior de Manera que la parte inferior del calentador sobresalga del borde de la mesa 2 Aplique ligeramente sellador para tube r as en la rosca NPT macho del codo Sostenga el regulador de presi n con una llave para tuber as cuando conecte el codo No apriete demasiado el codo al regulador El cuerpo del regulador se puede da ar NY la Tornillo Q para A madera ay E aa Pata de la base l i autorroscante Figura 13 Instalaci n de las patas de la base el calentador puede ser distinto del que aparece en la ilustraci n 3 Alinee los orificios en la pata de la base con los orificios de montaje en la parte inferior del gabinete consulte la figura 13 4 Asegure la pata de la base al calentador con los tornillos autorroscantes 5 Repita la operaci n en el otro extremo Montaje de las patas de la base en el piso 1 Quite el panel anterior consulte la sec ci n Desmontaje del panel anterior del calentador en la p gina 10 2 Coloque el calentador con las patas de la base en la ubicaci n deseada Marque lo
33. DESA HEATING PRODUCTS UNVENTED VENT FREE INFRARED GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL serviced by professionals who We recommend that our products be installed and are certified in the U S by NFI MODELS LCR16PT LCR18NT LCR26PT LCR3ONT HDR16PT HDR18NT HDR26PT HDR30NT A WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier fromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference For more information visit www desatech com TABLE OF CONTENTS SO mesura 2 AA TENES 4 UMPACKING esa ta ida 4 Product Identification oooonnicnnnnnnccnnnnnnnncnncco 4 Product Feat re S si sisean 4 Air For Combustion and Ventilation 5 SON cri 7 OPS AL ON sise ieties enerne 13 Ins
34. O DO IF YOU SMELL GAS e Do not try to light any appliance Do not touch any electric switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water MA ocon MN INSTRUCTIONS STOP Read the safety information start ing on page 13 Make sure equipment shutoff valve is fully open Turn off any electric power to the appli ance if service is to be performed Turn control knob clockwise to the OFF position Wait five minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information starting on page 13 If you don t smell gas go to the next step Turn control knob counterclockwise gt to the PILOT position Press in control knob for five 5 seconds With control knob pressed in push down and release ignitor button T
35. RECT INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages so the above limitation on implied warranties or exclusion or limitation on damages may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For information about this warranty write O ESA DESA Heating LLC 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com 1 866 672 6040 121255 01 Rev A Patent Pending 03 07 DESA HEATING PRODUCTS CALENTADOR DE GAS INFRARROJO NO VENTILADO SIN VENTILAS INFORMACI N DE SEGURIDAD Y MANUAL DE INSTALACI N We recommend that our products be installed and serviced by professionals who are certified in the U S by NFI National Fireplace Institute www nficertified org MODELOS LCR16PT LCR18NT LCR26PT LCR3ONT HDR16PT HDR18NT HDR26PT HDR30NT A ADVERTENCIA si la informaci n contenida en este manual no se sigue al pie de la letra se puede producir un incendio o una explosi n que podr a ocasionar da os ala propiedad lesiones personales o la p rdida de la vida No guarde ni utilice gasolina u otros vapores y l quidos inflamables cerca de este aparato ni de cualquier otro QU HACER SI PERCIBE OLOR A GAS e No intente encender ning n aparato e No
36. RVED PROBLEM Continued POSSIBLE CAUSE TROUBLESHOOTING REMEDY ODS pilot lights but flame goes out when control knob is released 11 2 Control knob not fully pressed in Control knob not pressed in long enough Equipment shutoff valve not fully open Thermocouple connection loose at control valve Pilot flame not touching thermocouple which allows thermocouple to cool caus ing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 1 2 Press in control knob fully After ODS pilot lights keep control knob pressed in 30 seconds Fully open equipment shut off valve Hand tighten until snug then tighten 1 4 turn more A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning page 16 or re place ODS pilot assembly 6 Thermocouple damaged 6 Replace pilot assembly 7 Control valve damaged 7 Replace control valve Burner s does notlight after 1 Burner orifice s is 1 Clean burner orifice s ODS pilot is lit clogged see Cleaning page 16 or replace burner orifice s 2 Inlet gas pressure is too 2 Contact local natural or low propane LP gas company Delayed ignition of burner s 1 Manifold pressure is too 1 Contact local natural or low propane LP gas company 2 Burner orifice s is 2 Clean burner orifice s clogged see Cleaning page
37. Ventilated Inl tAir Crawl Space Figure 3 Ventilation Air from Outdoors INSTALLATION NOTICE This heater is intended for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your primary heat source Ifyou have acentral heatingsystem you may run system s circulating blower while using heater This will help circulate the heat throughout the house In the event of a power outage you can use this heater as your primary heat source A WARNING A qualified ser vice person must install heater Follow all local codes CHECK GAS TYPE Use only the correct type of gas natural or propane LP If your gas supply is not the correct gas type do not install heater Call dealer where you bought heater for proper type heater AX WARNING This appliance is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rat ing plate Field conversion is not permitted INSTALLATION ITEMS Before installing heater make sure you have the items listed below e for propane LP gas external regulator supplied by installer piping check local codes e sealant resistant to propane LP gas equipment shutoff valve ground joint union sediment trap e tee joint pipe wrench e for natural gas test gauge connection ACSA design certified equipment shutoff valve with 1 8 NPT tap is an accept
38. a 10 2 Realice los pasos 1 a 7 de las nstruccio nes de encendido en la p gina 16 3 Con la perilla de control presionada encienda un f sforo Sostenga el f sforo en el piloto hasta que ste se encienda 4 Una vez que haya encendido el piloto mantenga la perilla de control presionada durante 30 segundos Despu s de los 30 segundos suelte la perilla de control Realice el paso 8 de las Instrucciones de encendido p gina 16 5 Vuelva a colocar el panel anterior 18 www desatech com 121255 01A INSPECCION DEL CALENTADOR Revise frecuentemente los patrones de la llama del piloto y de la llama del quemador PATR N DE LA LLAMA DEL PILOTO La figura 22 muestra un patr n correcto de la llama del piloto La figura 23 muestra un patr n incorrecto de la llama del piloto La llama incorrecta del piloto no toca el termopar Esto ocasionar que el termopar se enfr e Cuando el termopar se enfr e el calentador se apagar Si el patr n de la llama del piloto es incorrecto como se muestra en la figura 23 apague el calentador consulte C mo cerrar el suministro de gas al aparato en la p gina 18 consulte Soluci n de problemas en la p gina 21 Nota la llama del piloto en las unidades de gas natural presentar una ligera curva pero la llama deber ser azul sin color amarillo ni naranja Llama azul Quemador del piloto Termopar Figura 22 Patr n correcto de la lla
39. a figura 4 Si puede proporcione distancias mayores respecto al piso al techo y a las paredes adyacentes Puede ubicar el calentador en el piso lejos de la pared Se necesita un estante opcional para montaje en piso Adquiera el estante para montaje en piso con el distribuidor Consulte Accesorios p gina 25 TECHO Na _25 cm 10 ead Un minimo Distancias 7 de 91 4 cm m nimas 36 de los q laterales 7 del calentador i il Lado Lado derecho izquierdo Gin D__ Distancia m nima Ta la superficie de A 5 cm 2 la alfombra azulejo __ ___ u otro material PISO combustible Figura 4 Distancias minimas de montaje vistas desde la parte anterior del calentador 121255 01A INSTALACION Continuaci n ADVERTENCIA nunca ins tale el calentador en un dormitorio o ba o e en un veh culo recreativo e donde cortinas muebles ropa u otros objetos inflamables est n a menos de 91 5 cm 36 de las partes anterior superior O laterales del calentador e como aditamento de una chi menea e en reas de mucho tr fico e en reas con mucho viento o fuertes corrientes de aire A PRECAUCION si instala el calentador en la chochera de una casa e el piloto y el quemador del calentador deben estar por lo menos a 45 7 cm 18 sobre el piso e sit e el calentador donde nin g n veh culo en movimiento lo pueda golpear AX PRECAUCI N este calenta
40. able alter native to test gauge connection The optional CSA design certified equipment shutoff valve can be purchased from your dealer See Ac cessories page 21 121255 01A www desatech com T INSTALLATION Continued LOCATING HEATER This heater is designed to be mounted on a wall A WARNING Maintain the minimum clearances shown in Figure 4 If you can provide greater clearances from floor ceiling and joining wall You can locate heater on floor away from a wall An optional floor mounting stand is need ed Purchase the floor mounting stand from your dealer See Accessories page 21 A WARNING Never install the heater e in a bedroom or bathroom e in a recreational vehicle e where curtains furniture clothing or other flammable objects are less than 36 91 5 cm from the front top or sides of the heater e as a fireplace insert e in high traffic areas e in windy or drafty areas A CAUTION If you install the heater in a home garage e heater pilot and burner must be at least 18 45 7 cm above floor e locate heater where moving vehicle will not hit it AA CAUTION This heater creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as but not limited to to bacco smoke aromatic candles cleaning fluids oil or kerosene lamp
41. azables utilizadas en el calentador Al hacer un pedido de piezas siga las instrucciones provistas en Piezas de repuesto en la pagina 29 de este manual Rw ONO 10 11 12 13 14 15 16 17 18 19 20 21 22 23 N DE PARTE 107673 01 107673 03 107676 01 107676 05 103476 01 103476 02 kk 107894 12 107894 13 kk 103256 02 118721 02 118721 01 119099 01 119664 01 118661 01 099038 01 PP100 101547 01 100642 03 105345 01 109121 01 Panel anterior Panel anterior Resguardo de rejilla Guarnici n Armadura de reflector Armadura de reflector E Panel posterior del gabinete 097159 04 099066 02 098271 09 107896 01 107896 02 111421 01 120378 01 099415 18 099415 19 104819 02 098522 24 102394 02 Protector de calor Casquillos a presi n Patas de base V lvula de gas del termostato Soporte de montaje para v lvula de termostato E Tubo de entrada Pantalla deflectora superior Pantalla deflectora superior Pantalla deflectora inferior Interruptor de l mite t rmico Tuber a de alojamiento Buje para atenuar deformaciones Paquete de ventilador jejeje Casquillos a presi n 202020 bee es PARTES DISPONIBLES NO ILUSTRADAS mmm DESCRIPCI N Panel anterior Panel anterior Resguardo de rejilla Encendido piezoel ctrico Soporte de montaje Cable del encendedor Protector de calor Regulador de propano gas LP
42. ble es nuestra garantia estandar por escrito No otorgamos ninguna otra garantia expresa o impl cita GARANT A LIMITADA PARA PRODUCTOS NUEVOS Y REACONDICIONADOS DE F BRICA Productos nuevos DESA Heating LLC garantiza este calentador y todas sus partes contra cualquier defecto en los materiales y mano de obra por dos 2 a os a partir del d a de la compra siempre y cuando se haya operado y dado mantenimiento de acuerdo con la instrucciones del fabricante Estas garant as se extienden solamente al comprador minorista original cuando se proporciona un comprobante de compra Calentadores reacondicionados de f brica DESA Heating LLC garantiza este calentador y cualquiera de sus partes contra cualquier defecto en los materiales y mano de obra por treinta 30 d as a partir del d a de la compra siempre y cuando se haya operado y dado mantenimiento de acuerdo con la instrucciones del fabricante Estas garant as se extienden solamente al comprador minorista original cuando se proporciona un comprobante de compra Esta garant a cubre nicamente al comprador minorista original Esta garant a s lo cubre el costo de las piezas requeridas para restablecer este calentador a su condici n de operaci n adecuada Las piezas de garant a SE DEBEN obtener por medio de los distribuidores autorizados de este producto y de DESA Heating LLC quienes proporcionar n las piezas de repuesto originales de f brica Si no se utilizan piezas de repuesto ori
43. caci n de entrada agregada de todos los aparatos instalados en ese es pacio y define el espacio no confinado como aquel cuyo volumen no es menor de 4 8 m por kW 50 pies c bicos por 1 000 BTU h de clasificaci n de entrada agregada de todos los aparatos instalados en ese espacio Las habitaciones que se comunican directamente con el espacio en el que los aparatos est n instalados mediante aberturas que no ten gan puertas se consideran parte del espacio no confinado Se considera que las habitaciones adyacen tes est n comunicadas s lo si hay accesos sin puertas o si hay rejillas de ventilaci n entre ellas DETERMINACI N DEL FLUJO DE AIRE FRESCO PARA UBICAR EL CALENTADOR C mo determinar si tiene un espacio confinado o no confinado Utilice esta hoja de trabajo para determinar si tiene un espacio confinado o no confinado Espacio incluye la habitaci n en la que se va a instalar el calentador m s todas las habi taciones adyacentes que tengan accesos sin puerta o rejillas de ventilaci n entre ellas 1 Determine el volumen del espacio largo x ancho x altura Largo x ancho x altura m pies volumen del espacio Ejemplo Tama o del espacio 6 1 m 20 pies largo x 4 88 m 16 pies ancho x 2 44 m 8 pies altura del techo 72 49 m 2560 pies volumen del espacio Si se proporciona ventilaci n adicional a las habitaciones adyacentes por medio de rejillas o aberturas agregue el volumen de stas al
44. caliente adentro Durante la temporada de calor los propietarios de las casas desean que sus hogares est n tan her m ticos como sea posible Aunque es bueno hacer que su casa sea eficiente en cuanto al ahorro de energ a sta tambi n necesita ventilaci n Es necesario que entre aire fresco a su casa Todos los aparatos que queman combustible necesi tan aire fresco para que su combusti n y su ventilaci n sean adecuadas Los ventiladores de expulsi n de aire las chimeneas las secadoras de ropa y los apa ratos que queman combustible toman aire de la casa durante su funcionamiento Usted debe proporcionar la cantidad adecuada de aire fresco para estos aparatos Esto asegu rar que la ventilaci n para los aparatos que queman combustible sea la adecuada C MO PROCURAR LA VENTILACI N ADECUADA Los siguientes son extractos del C digo nacional de gas combustible ANSI Z223 1 NFPA 54 sec ci n 5 3 Aire para combusti n y ventilaci n Todos los espacios en las casas se pueden clasificar en una de las tres categor as de ventilaci n siguientes 1 Construcci n inusualmente sellada 2 Espacio no confinado 3 Espacio confinado La informaci n de las p ginas 5 a la 7 le ayu dar a clasificar su espacio y a proporcionar la ventilaci n adecuada Construcci n inusualmente sellada El aire que se filtra por los bordes de las puer tas y ventanas puede proporcionar suficiente aire fresco para la combusti n y la
45. cance para realizar la conexi n del medidor de prueba La conexi n NPT debe estar antes del calentador consulte la figura 15 p gina 13 IMPORTANTE instale una v lvula de cierre de equipo en un lugar que sea accesible La v lvula de cierre de equipo es para abrir o cerrar el suministro de gas al aparato Aplique una peque a cantidad de sellador de tuber a a las roscas NPT macho Esto evitar que el exceso de sellador entre a la tuber a El exceso de sellador en la tuber a puede ocasionar que las v lvulas del calentador se tapen AAADVERTENCIA use sellador para tuber a que sea resistente al gas de petr leo l quido LP Instale la trampa de sedimentos en la l nea de suministro como se muestra en la figura 15 Sit e la trampa de sedimentos de manera que se pueda tener acceso a ella para limpieza Sit e la trampa de sedimentos donde sea poco probable que los materiales atrapados en ella se congelen La trampa de sedimentos atrapa humedad y contaminantes Esto evita que los sedimentos lleguen a los controles del calentador Si la trampa de sedimentos no se instala o se instala incorrectamente el calen tador podr a no funcionar correctamente IMPORTANTE sujete el regulador de presi n con una llave cuando lo conecte a la tuber a de gas o a otros conectores No apriete dema siado la conexi n de la tuber a al regulador El cuerpo del regulador se podr a da ar REVISI N DE LAS CONEXIONES DE GAS AX
46. clusiones o limitaciones de los da os incidentales o emergentes de manera que es posible que la limita ci n anterior referente a las garant as impl citas o la exclusi n o limitaci n de da os no se aplique a usted Esta garant a le otorga derechos legales espec ficos y usted podr a tener tambi n otros derechos que var an de un estado a otro Para obtener informaci n sobre esta garant a escriba a DESA DESA Heating LLC 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com 1 866 672 6040 121255 01 Rev A 121255 01 03 07 NOT A UPC Patente en tr mite
47. de repuesto originales Esto proteger la cobertura de su garant a para partes reemplazadas con garant a PIEZAS CON GARANT A P ngase en contacto con los distribuidores au torizados de este producto Si no pueden pro porcionarle las piezas originales de repuesto llame al departamento de servicio t cnico de DESA Heating Products al 1 866 672 6040 Cuando llame a DESA Heating Products tenga listo su nombre e su direcci n los n meros de modelo y de serie de su calentador e la falla del calentador el tipo de gas utilizado propano o gas LP o gas natural e la fecha de compra Generalmente le pediremos que devuelva la pieza a la f brica PIEZAS SIN GARANT A P ngase en contacto con los distribuidores autorizados de este producto Si ellos no pueden proveer piezas de repuesto origina les comun quese con la Central de piezas m s cercana o bien llame a DESA Heating Products al 1 866 672 6040 para obtener informaci n de referencia Cuando llame a DESA Heating Products tenga listo el n mero del modelo de su calentador el n mero de la pieza de reemplazo PUBLICACIONES DE SERVICIO Puede adquirir un manual de servicio en la direcci n que se indica en el reverso de este manual Env e un cheque de 5 00 a nombre de DESA Heating Products CENTRAL DE PIEZAS Estas Centrales de piezas son empresas privadas Han aceptado dar asistencia a las nece sidades de nuestros clientes ofr
48. dor crea corrientes de aire calien te Estas corrientes mueven el calorhacia la superficie de las pa redes pr ximas al calentador La instalaci n del calentador cerca de recubrimientos de pared vinilo o tela y la operaci n del calen tador en lugares donde existan impurezas en el aire como humo de tabaco velas arom ticas l quidos limpiadores l mparas de aceite o queroseno entre otros puede decolorar las paredes o producir olores IMPORTANTE los calentadores sin ventila ci n a aden humedad al aire Aunque esto es ben fico la instalaci n del calentador en habitaciones sin suficiente aire de ventilaci n puede ocasionar la formaci n de moho debido al exceso de humedad Consulte Aire para combusti n y ventilaci n p gina 5 Si hay mucha humedad se puede utilizar un des humidificador para ayudar a reducir el vapor de agua contenido en el aire Para mayor comodidad y eficiencia instale el calentador donde haya f cil acceso para la operaci n inspecci n y reparaci n en la parte m s fr a de la habitaci n Si esta planeando utilizar el ventilador sit e el calentador cerca de un enchufe el ctrico BULBO SENSOR DE TERMOSTATO El bulbo sensor de termostato se ubica en la parte inferior del calentador 1E Coloque la abrazadera en el bulbo sensor de termostato como se muestra en la figura 5 La abrazadera se incluye en el paquete de ferreter a Coloque la abrazadera en el orificio de montaje
49. e Gas odor during combustion Foreign matter between control valve and burner Gas leak See Warning statement at top of page Take apart gas tubing and remove foreign matter Locate and correct all leaks see Checking Gas Con nections page 12 Heater produces a whistling noise when burner is lit 20 Air in gas line Air passageways on heater blocked Dirty or partially clogged burner orifice www desatech com Operate burner until air is removed from line Have gas line checked by local natural or propane LP gas company Observe minimum installa tion clearances see Figure 4 page 8 Clean burner see Clean ing page 16 or replace burner orifice 121255 01A SPECIFICATIONS LCR18NT HDR18NT e Natural Gas e 18 000 Btu hr e Piezo Ignition e Pressure Regulator Setting 6 W C e Inlet Gas Pressure in of water Maximum 10 5 W C Minimum 7 W C e Average Heater Weight 22 Ib 10 kg e Average Shipping Weight 25 5 Ib 11 6 kg LCR30NT HDR30NT e Natural Gas 30 000 Btu hr e Piezo Ignition e Pressure Regulator Setting 6 W C e Inlet Gas Pressure in of water Maximum 10 5 W C Minimum 7 W C Average Heater Weight 29 Ib 13 2 kg Average Shipping Weight 33 Ib 15 kg LCR16PT HDR16PT e Propane LP Gas 16 000 Btu hr e Piezo Ignition e Pressure Regulator Setting 8 W C e Inlet Gas Pressure in of
50. e sediment trap where it is within reach for cleaning Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly IMPORTANT Hold the pressure regulator with wrench when connecting it to gas pip ing and or fittings Do not over tighten pipe connection to regulator The regulator body could be damaged CHECKING GAS CONNECTIONS WARNING Testall gas piping and connections internal and external to unit for leaks after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a leak Apply a noncorrosive leak detection fluid toalljoints Bubbles forming show a leak Correct all leaks at once CAUTION For propane LP gas make sure external regula tor has been installed between propane LP supply and heater See guidelines under Connect ing to Gas Supply page 11 PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply piping system by either
51. eciendo piezas de repuesto y accesorios originales Those Heater Guys 255 E Stowell Street Upland CA 91786 909 982 3011 Tool 8 Equipment Co 5 Manila Ave Hamden CT 06514 EE UU 1 800 397 7553 203 248 7553 Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 EE UU 219 462 7441 1 888 619 7060 www portableheaterparts com sales portableheaterparts com techservice portableheaterparts com FBD 1349 Adams Street Bowling Green KY 42103 EE UU 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 EE UU 616 791 0505 1 800 446 1446 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 EE UU KS MO AR 816 842 3911 www washerparts com East Coast Energy 10 East Route 36 W Long Branch NJ 07764 EE UU 732 870 8809 1 800 755 8809 www njplaza com ecep 21st Century 2950 Fretz Valley Perkasie PA 18944 EE UU 215 795 0400 800 325 4828 Laporte s Parts amp Service 2444 N 5th Street Hartsville SC 29550 EE UU 843 332 0191 Parts Department Cans Unlimited P O Box 645 Taylor SC 29687 EE UU 803 879 3009 1 800 845 5301 cuisales aol com 121255 01A www desatech com 29 GARANT A GUARDE ESTA GARANT A Modelo N de serie Fecha de compra Siempre especifique los numeros de modelo y de serie cuando se comunique con la fabrica La unica garantia aplica
52. el posterior del calentador consulte la figura 12 Marque la ubicaci n de los tornillos en la pared Quite el calentador del soporte de montaje Si va a instalar los tornillos de montaje inferiores en una pared hueca o s lida instale los anclajes de pared Siga los pa sos 1 a 4 en M todo de fijoci n a anclajes de pared Si va a instalar el tornillo inferior de mon taje en la viga de pared perfore orificios en los lugares marcados con una broca de 9 64 Vuelva a colocar el calentador en el so porte de montaje P Vista frontal Quo Separador Vista lateral Figura 12 Instalaci n de los tornillos de montaje inferiores 121255 01A www desatech com 11 INSTALACION Continuaci n 6 Coloque los separadores entre los orifi cios de montaje inferiores y el anclaje de pared o el orificio que perfor 7 Sostenga el separador en su sitio con una mano Con la otra mano inserte el tornillo de montaje a trav s del orificio inferior de montaje y del separador Coloque la punta del tornillo en la abertura del anclaje de pared o del orificio que perfor 8 Apriete los tornillos hasta que el calen tador est asegurado firmemente a la pared No los apriete demasiado Nota no vuelva a colocar el panel ante rior en este momento Coloque el panel anterior despu s de hacer las conexiones de gas y de revisar si hay fugas consulte la p gina 13 MONTAJE DEL C
53. el regulador de presi n 6 de c a e Presi n del gas de entrada pulg de agua M ximo 10 5 de c a M nimo 7 de c a e Peso promedio del calentador 13 2 kg 29 Ib e Peso promedio del paquete de envio 15 kg 33 Ib LCR16PT HDR16PT Propano o gas LP e 16 000 Btu h e Encendido piezoel ctrico Ajuste del regulador de presi n 8 de c a Presi n del gas de entrada pulg de agua M ximo 14 de c a M nimo 11 de c a e Peso promedio del calentador 10 kg 22 Ib e Peso promedio del paquete de env o 11 6 kg 25 5 Ib LCR26PT HDR26PT Propano o gas LP 26 000 Btu h Encendido piezoel ctrico e Ajuste del regulador de presi n 8 de c a e Presi n del gas de entrada pulg de agua M ximo 14 de c a M nimo 11 de c a e Peso promedio del calentador 13 2 kg 29 lb e Peso promedio del paquete de env o 5 kg 33 Ib Nota las dimensiones que se presentan en la lista son los puntos m s extremos del calentador incluyen las perillas de control y la rejilla Para prop sitos de ajustes de entrada ACCESORIOS Adquiera estos accesorios del calentador con el distribuidor local Si ste no puede proveer estos accesorios comun quese con la Central de piezas m s cercana consulte la p gina 29 o llame a DESA Heating Products al 1 866 672 6040 para obtener informaci n de referencia Tambi n puede escribir a la di recci n que se encuentra en la ltima p gina de este man
54. ene que proporcionar aire fresco adicional Sus opciones son las siguientes A Vuelva a calcular la hoja de trabajo agregan do el espacio de una habitaci n adyacente Si el espacio adicional genera un espacio no confinado quite la puerta de la habitaci n adyacente o instale rejillas de ventilaci n entre las habitaciones Consulte Aire del interior de la construcci n para ventilaci n en la p gina 7 B Ventile la habitaci n directamente desde el exterior Consulte Aire del exterior para ventilaci n en la p gina 7 C Instale un calentador de menos BTU h si una menor cantidad de BTU h hace la habitaci n sea no confinada Si la cantidad real de BTU h que se utiliza es menor que la cantidad m xima que el espacio puede admitir el espacio es no confinado No necesitar ventilaci n de aire fresco adicional 6 www desatech com 121255 01A AIRE PARA COMBUSTION Y VENTILACION Continuacion AX ADVERTENCIA si el rea en la que el calentador va a fun cionar es m s peque a que la que se define como espacio no confinado o si el edificio tiene una construcci n inusualmente sellada proporcione suficiente aire para combusti n y ven tilaci n mediante uno de los m todos descritos en el C digo nacional de gas combustible ANSI Z223 1 NFPA 54 secci n 5 3 o en los c digos locales aplicables AIRE PARA VENTILACI N Aire del interior de la construcci n para ventilaci n Este aire fresc
55. er using sheet metal screws 5 Repeat for other side O NY Wood gt Screw JE jg Sheet A Metal AS Base Foot y Screw Figure 13 Installing Base Feet actual heater may vary from illustration Mounting Base Feet to Floor 1 Remove front panel see Removing Front Panel of Heater page 9 2 Position heater with base feet in desired location Mark holes for drilling Remove heater with base 3 For carpeted floors make a small cut with a sharp knife at marked locations prior to drilling If mounting base to a wood floor drill 1 8 diameter hole 3 4 deep Do not use anchors in wood floors If mounting base to a concrete floor drill with 1 4 diameter concrete drill bit 1 s into floor Insert anchors completely into holes 4 Reposition heater with base feet over holes Secure base to floor with wood screws See Figure 13 CONNECTING TO GAS SUPPLY Ay WARNING This appliance requires a 3 8 NPT National Pipe Thread inlet connection to the pressure regulator AR WARNING A qualified service person mustconnectheaterto gas supply Follow all local codes A WARNING Fornatural gas never connect heater to private non util ity gas wells This gas is commonly known as wellhead gas IMPORTANT For natural gas check gas line pressure before connecting heater to gas line Gas line pressure must be no greater than 10 5 of water If gas line pressure
56. es un calentador de llama de gas sin ventilaci n Utiliza aire ox geno de la habitaci n en la que se instala Se deben tomar las medidas necesarias para asegurar que haya suficiente aire para ven tilaci n y combusti n Consulte la secci n Aire para combusti n y venti laci n en la p gina 5 de este manual 2 www desatech com Soluci n de problemas ooocoocccnnccnnncincccconccncnnos 21 Especificaciones ACCOSOMOS iiie Consejos para servicio Servicio t cnico Piezas de repuesto Publicaciones de servicio Central de piezas A dens Contraportada Este aparato esta disenado para usarse unicamente con el tipo de gas indicado en la placa de clasifica ci n Este aparato no se puede convertir para que utilice otro tipo de gas Este aparato puede serins talado en una casa m vil con ubicaci n permanente y adquirida en el mercado de posventa siempre que no est prohibido por los c digos locales Mercado de posventa venta completada por parte del fabricante sin fines de reventa A ADVERTENCIA este produc to contiene y o genera qu micos reconocidos por el estado de California como causantes de c ncer defectos de nacimiento u otros da os reproductivos IMPORTANTE lea este manual del propietario cuidadosa y completamente antes de intentar ensamblar operar o dar ser vicio a este calentador El uso inadecuado de este calentado
57. geways Use pressurized air to clean Exterior Use a soft cloth dampened with a mild soap and water mixture Wipe the cabinet to re move dust SERVICE HINTS When Gas Pressure Is Too Low e pilot will not stay lit burner will have delayed ignition e heater will not produce specified heat propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local natural or propane LP gas supplier TECHNICAL SERVICE You may have further questions about instal lation operation or troubleshooting If so contact DESA Heating Products Technical Service Department at 1 866 672 6040 When calling please have your model and serial numbers of your heater ready You can also visit DESA Heating Products tech nical service web site at www desatech com 121255 01A www desatech com DY TROUBLESHOOTING RWARNING Turn offand unplug heaterand letcool before servicing Only a qualified service person should service and repair heater A CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot unit Note All troubleshooting items are listed in order of operation OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed in there is no spark at ODS pilot il 2 3 NOOO Ignitor electrode positioned wrong Ignitor electrode broken Ignitor electrode not con nected to ignitor cable Ignito
58. ginales de f brica esta garant a quedar anulada Un instalador capacitado DEBE haber instalado el Calentador de acuerdo con todos los c digos locales e instrucciones incluidas con la unidad Esta garant a no se aplica a las piezas que no est n en su condici n original debido al desgaste y ruptura normales ni a las piezas que fallen o se da en como resultado de uso incorrecto accidentes falta de mantenimiento adecuado o defectos ocasionados por una instalaci n incorrecta Los vi ticos gastos de diagn stico mano de obra transporte y todos los costos de naturaleza similar que se relacionen con la reparaci n de un calentador defectuoso ser n responsabilidad del propietario HASTADONDE LO PERMITALE LEY DE LA JURISDICCI N QUE REGULALAVENTA DEL PRODUCTO ESTA GARANT A EXPL CITA EXCLUYE ATODAS Y CADAUNADE LAS DEM S GARANT AS EXPL CITAS Y LIMITA LA DURACI N DE TODAS Y CADAUNADE LAS GARANT AS IMPL CITAS INCLUSO LAS GARANT AS DE MERCANTIBILIDAD E IDONEIDAD PARA UN PROP SITO PARTICULAR ADOS 2 A OS PARA TODOS LOS COMPONENTES A PARTIR DE LA FECHA DE LA PRIMERA COMPRA Y EL PRESENTE DOCUMENTO LIMITA LA RESPONSABILIDAD DE DESA HEATING LLC AL PRECIO DE COMPRA DEL PRODUCTO DE MANERA QUE DESAHEATING LLC NO SER RESPONSABLE POR NING N OTRO DA O EN ABSOLUTO LO QUE INCLUYE LOS DA OS INDIRECTOS INCIDENTALES O EMERGENTES En algunos estados no se permiten las limitaciones en cuanto a la duraci n de las garant as impl citas o las ex
59. hace que el termopar se enfr e y ocasiona que la llama del piloto se extinga Este pro blema puede ser ocasionado por alguna de las siguientes condiciones o por ambas A Baja presi n del gas B El piloto con ODS est su cio o parcialmente tapado El termopar est da ado La v lvula de control est da ada Presione totalmente la peri lla de control Despu s de que el piloto con ODS se encienda mantenga la perilla de control presiona da durante 30 segundos Abra la v lvula de cierre del equipo totalmente Apriete con la mano hasta que sienta que topa luego apriete 1 4 de vuelta m s A Comun quese con la compa a local de gas natu ral o de propano o gas LP B Limpie el piloto con ODS consulte Limpieza en la p gina 20 o reemplace el conjunto de piloto y ODS Reemplace el conjunto de piloto Reemplace la v lvula de control El los quemador es no se enciende n despu s de que el piloto con ODS est encendido Los orificios del quemador est n tapados La presi n del gas de entra da es muy baja Limpie los orificios del que mador consulte Limpieza en la p gina 20 o reemplace los orificios del quemador Comun quese con la com pa a local de gas natural o de propano o gas LP Hay un retraso en el encendi do de los quemadores La presi n del tubo m ltiple es muy baja Los orificios del quemador est n
60. his will light pilot The pilot is attached to the front of burner www desatech com 10 Note You may be running this heater for the first time after hooking up to gas sup ply If so you may need to press in control knob for 30 seconds or more This will allow air to bleed from the gas system If needed keep pressing ignitor button until pilot lights If ignitor does not light pilot re fer to Troubleshooting page 18 or contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure page 15 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 thru 7 Waitone 1 minute before lighting pilot again Turn control knob counterclockwise gt to desired heating level The main burner should light To leave pilot lit and shut off burners only turn control knob clockwise to the PILOT position A CAUTION Do not try to ad just heating levels by using the equipment shutoff valve Ignitor Button Thermocouple Figure 19 Control Knob In The OFF Position Ignitor Electrode Figure 20 Pilot 121255 01A OPERATION Continued TO SELECT HEATING LEVEL
61. incluyendo el piloto Deje que la unidad se enfr e durante al menos treinta minutos 2 Inspeccione el piloto del quemador en busca de polvo y tierra 3 Haga pasar aire a trav s de los puertos O ranuras y los orificios del quemador 4 Nunca inserte objetos en el tubo del piloto Limpie tambi n el conjunto del piloto Una punta amarilla en la llama del piloto indica la presencia de polvo y suciedad en el conjunto de piloto Hay un peque o orificio de entrada de aire al piloto a aproximadamente 5 cm 2 de donde sale la llama del piloto consulte la figura 26 Con la unidad apagada introduzca aire suavemente a trav s de la entrada de aire Si no cuenta con aire comprimido puede soplar a trav s de una pajilla o popote Conjunto de piloto Entrada de aire al piloto Figura 26 Entrada de aire del piloto GABINETE Conductos de aire Use aire a presi n para la limpieza Exterior Utilice un pa o humedecido con una mezcla de agua y jab n suave Frote el gabinete para quitar el polvo 20 www desatech com 121255 01A SOLUCION DE PROBLEMAS A ADVERTENCIA apague y desconecte el calentador y deje que se enfr e antes de darle servicio S lo una persona de servicio ca pacitada debe reparar el calentador o darle servicio piloto con ODS A PRECAUCION nunca utilice un alambre aguja u objetos pa recidos para limpiar el piloto ODS Esto puede da ar la unidad de Nota todos los punto
62. ing ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from the house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Confined Space The information on pages 5 through 7 will help you Classify your space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 101 kg per pa sec m or less with openings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall
63. ion location room size open air temperatures etc Frequent use of your heater will let you determine your own comfort levels MANUAL LIGHTING PROCEDURE Remove front panel see Figure 7 page 9 a Follow steps 1 through 7 under Lighting Instructions page 14 3 With control knob pressed in strike match Hold match to pilot until pilot lights 4 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob Now follow step 9 under Lighting Instructions page 14 5 Replace front panel 121255 01A www desatech com 15 INSPECTING HEATER Check pilot flame pattern and burner flame pattern often PILOT FLAME PATTERN Figure 22 shows a correct pilot flame pattern Figure 23 shows an incorrect pilot flame pat tern The incorrect pilot flame is not touching the thermocouple This will cause the thermo couple to cool When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 23 e turn heater off see To Turn Off Gas to Ap pliance page 15 see Troubleshooting page 18 Note The pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color Blue Flame Pilot Burner Thermocouple Figure 22 Correct Pilot Flame Pattern Yellow Flame Thermocouple Pilot Burner Figure 23 Incorrect Pilot Flame Pattern BURNER FLAME PATTERN Figure
64. ipo Cerrada Figura 16 V lvula de cierre del equipo V lvula de gas de termostato Medidor de gas V lvula de cierre del equipo Figura 17 Revisi n de las uniones de gas para gas natural COMPROBACI N DE LA PRESI N DE LAS CONEXIONES DE GAS DEL CALENTADOR 1 2 8 Tanque de suministro de propano Abra la v lvula de cierre del equipo con sulte la figura 16 Si usa gas natural abra la v lvula princi pal de gas ubicada en el medidor de gas o cerca de ste Si usa propano o gas LP abra la v lvula de suministro de propano o gas LP Compruebe que la perilla de control del calentador est en la posici n OFF apa gado Revise todas las uniones entre la v lvula de cierre del equipo y v lvula de gas del termostato consulte la figura 17 18 Aplique en todas las uniones alg n l quido de detecci n de fugas que no sea corro sivo La formaci n de burbujas indicar una fuga Repare todas las fugas inmediatamente Encienda el calentador consulte Fun cionamiento en la p gina 16 Revise el resto de las uniones internas para ver si hay fugas Apague el calentador consulte C mo cerrar el suministro de gas al aparato en la p gina 18 Vuelva a colocar el panel anterior V lvula de gas de termostato
65. liquids A WARNING Any change to this heater or its controls can be dangerous WARNING Donotuseablow er insert heat exchanger insert or other accessory not approved for use with this heater Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects on the heater Surface of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shut down Allow surface to cool before touching Carefully supervise young chil dren when they are in the same room with heater Make sure grill guard is in place before running heater 121255 01A 1 10 11 of gas indicated on the rating plate Thi appliance is not convertible for use wit other gases This appliance is only for use with the type s h Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors This heater shall not be installed in a bedroom or bathroom If you smell gas Shut off gas supply Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas
66. ma del piloto Llama amarilla Quemador del piloto Termopar Figura 23 Patr n incorrecto de la llama del piloto PATR N DE LA LLAMA DEL CALENTADOR La figura 24 muestra un patr n correcto de la llama del quemador La figura 25 muestra un patr n incorrecto de la llama del quemador Si el patr n de la llama del quemador es inco rrecto como se muestra en la figura 25 apague el calentador consulte C mo cerrar el suministro de gas al aparato en la p gina 18 e consulte Soluci n de problemas en la p gina 21 Figura 24 Patr n correcto de la llama del quemador Figura 25 Patr n incorrecto de la llama del quemador 121255 01A www desatech com 19 LIMPIEZA ADVERTENCIA apague el calentador y deje que se enfr e antes de limpiarlo PRECAUCI N debe mante ner limpias las reas de control el quemador y los pasajes de circulaci n de aire del calentador Inspeccione estas reas del ca lentador antes de cada uso Haga que una persona de servicio calificada inspeccione el calen tador una vez al a o Es posible que el calentador requiera de limpieza m s frec
67. miento de ox geno ODS El piloto con ODS es una caracter stica necesaria de los calentadores sin ventilaci n para habitacio nes El piloto con ODS apaga el calentador cuando no hay suficiente aire fresco SISTEMA DE ENCENDIDO PIEZOEL CTRICO Este calentador tiene un encendido piezoel ctri co Este sistema no necesita f sforos bater as ni otros medios para encender el calentador CONTROL DE CALOR CON TERMOSTATO Los modelos con termostato tienen un bulbo sensor del termostato y una v lvula de con trol Esto ofrece gran comodidad al usar el calentador Tambi n puede producir menores gastos por concepto de gas AIRE PARA COMBUSTI N Y VENTILACI N AX ADVERTENCIA este calen tador no debe instalarse en un espacio confinado nien una cons trucci n inusualmente sellada a menos que se hayan tomado las medidas necesarias para propor cionar el aire adecuado para la combusti n y la ventilaci n Lea las instrucciones siguientes para asegurarse de que su hogar cuen tecon la cantidad adecuada de aire fresco para ste y otros aparatos que queman combustible Hoy m s que nunca las casas est n dise adas para ser m s eficientes en el ahorro de energ a Los nuevos materiales un mejor aislamiento y los nuevos m todos de construcci n ayudan a reducir la p rdida de calor en las casas Los propietarios de las casas aplican sellador alre dedor de las ventanas y puertas para mantener el aire fr o afuera y el
68. ne LP fuel tank ofless than 100 Ibs 45 kg capacity 14 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 15 Provide adequate clearances around air openings LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts UNPACKING 1 Remove heater from carton 2 Remove all protective packaging applied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly return to where you bought heater PRODUCT IDENTIFICATION Control Knob Ignitor Button Grill Guard Plaque Front Panel Heater Cabinet Figure
69. o o una explosi n No use este aparato si alguna de sus partes estuvo sumergida en agua Llame inmediatamente a un t cnico capacitado de servicio para que ins peccione el aparato y reemplace las piezas del sistema de control y los controles de gas que hayan estado sumergidos en agua E INSTRUCCIONES DE ENCENDIDO 1 2 ALTO Lea la informaci n de seguridad en la columna 1 Aseg rese de que la v lvula de cierre del equipo est completamente abierta Si va a realizar alg n trabajo de mante nimiento desconecte el suministro de energ a el ctrica al calentador Gire la perilla de control en direcci n de la manecillas del reloj hasta la posici n OFF apagado Espere cinco minutos a que se disipe el gas Luego compruebe que no huela a gas incluso cerca del piso Si percibe olor a gas DET NGASE Realice el inciso B de la informaci n de seguridad en la columna 1 Si no percibe olor a gas contin e con el siguiente paso Gire la perilla de control en direcci n contraria a las manecillas del reloj hasta la posici n PILOT piloto Manten ga presionada la perilla de control durante cinco 5 segundos Contin e presionando la perilla de control y al mismo tiempo oprima y suelte el bot n de encendido Esto encender el piloto El piloto est instalado en la parte anterior del quemador Nota es posible que sta sea la primera vez que hace funcionar el calentador des pu s de conec
70. o viene de un espacio adya cente no confinado Cuando se ventila a un espacio adyacente no confinado en la pared que conecta los dos espacios debe haber dos aberturas permanentes una a 30 5 cm 12 del techo y otra a 30 5 cm 12 del piso vea las opciones 1 y 2 en la figura 2 Tambi n se puede quitar la puerta de la habitaci n adyacente consulte la opci n 3 en la figu ra 2 Consulte el C digo nacional de gas combustible ANSI Z223 1 NFPA 54 secci n EZ 30 5 cm 12 S i Rejillas de ventilaci n hacia una habitaci n adyacente Opci n 2 Rejillas de ventilaci n hacia una habitaci n adyacente opci n 1 O quite la puerta hacia la habitaci n adyacente opci n 3 Figura 2 Aire del interior de la construcci n para ventilaci n 5 3 Aire para combusti n y ventilaci n para conocer el tama o requerido de las rejillas o conductos de ventilaci n Aire del exterior para ventilaci n Proporcione aire fresco adicional mediante el uso de rejillas o conductos de ventilaci n Debe proporcionar dos aberturas permanen tes una dentro de 30 5 cm 12 desde el techo y otra dentro de 30 5 cm 12 desde el piso Conecte estos elementos directamente al exterior o a los espacios que est n abiertos al exterior Estos espacios incluyen ticos y espacios debajo del piso de la casa Consulte el C digo nacional de gas combustible ANSI Z223 1 NFPA 54 secci n 5 3 Aire para
71. ooms with doorless pas sageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height cu ft volume of space Example Space size 20 ft 6 1 m length x 16 ft 4 88 m width x 8 ft 2 44 m ceiling height 2560 cu ft 72 49 m volume of space If additional ventilation to adjoining room is supplied with grills or openings add the volume of these rooms to the total volume of the space Multiply the space volume by 20 to determine the maximum Btu Hr the space can support volume of space x 20 Maxi mum Btu Hr the space can support Example 2560 cu ft 72 49 m volume of space x 20 51 200 maximum Btu Hr the space can support Add the Btu Hr of all fuel burning appliances in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors Example Gas water heater 40 000 Btu Hr Vent free heater _ 20 000 Btu Hr Total 60 000 Btu Hr Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu Hr maximum can support Btu Hr actual amount used Example 51 200 Btu Hr maximum the space can support 60 000 Btu Hr actual amount of Btu Hr
72. opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 12 www desatech com 121255 01A INSTALLATION Continued 4 Check all joints of gas supply piping system Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 16 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter for natural gas see Figure 17 or propane LP supply tank for propane LP gas to equipment shutoff valve see Figure 18 Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open equipment shutoff valve see Fig ure 16 2 For natural gas open main gas valve located on or near gas meter For pro pane LP gas open propane LP supply tank valve 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to thermostat gas valve see Figure 17 or
73. or Tanque de suministro A de propano x o gas LP Ventila apuntando hacia abajo ERRADA as Figura 14 Regulador externo con la ventila apuntando hacia abajo Regulador de presi n Niple para tuber a de Soporte del ae Upo regulador NPT Gabinete del Union calentador pulimentada sin rosca Uni n T ES Ll i V lvula de re uc or cierre del a 1 8 tipo equipo Gas natural Del T M n medidor de gas 5 3 presi n de 7 a 10 5 de c a Uni n Tubo de Tap n Propano o gas I T tuber a j LP Del regulador externo presi n Conexi n del medidor de prueba Trampa de sedimentos de 11 a 14 de c a Consulte las instrucciones de las conexiones L nea flexible Consulte la ilustraci n anterior para m s detalles Conexi n mediante l nea flexible Figura 15 Conexi n de gas Codo 3 8 NPT a 1 2 abocinado de 90 Una v lvula de cierre de equipo con dise o certificado por la CSA con rosca tipo NPT de 1 8 es una alternativa aceptable como conexi n para el medidor de prueba Ad quiera la v lvula opcional de cierre de equipo certificada con dise o CSA del distribuidor Consulte Accesorios p gina 25 121255 01A www desatech com 13 INSTALACION Continuaci n La instalaci n debe incluir la v lvula de cierre del equipo la uni n y la rosca tipo NPT con tap n de 1 8 Sit e el conector con rosca NPT a su al
74. pecting Heater 0 0 0 0 eeeeeeeeeeeeteeeeeeeeeeeeee 16 CIS ANING cc cc 16 SAFETY WARNING Improper installation adjustment alteration service or main tenance can cause injury or property damage Refer to this manual for correct installation and operation al procedures For assis tance or additional infor mation consult a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen fromthe room inwhich itis installed Provisions for adequate combustion and ventila tion air must be provided Refer to Airfor Combustion and Ventilation section on page 5 of this manual This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases www desatech com Semice HINIS vision alga Technical ServiCe ooocconncconnccinccnonnccocccnnncnancnnno 17 TroublESOOUNO cocaina 18 e decgsdescnevsiiersseaaseesctee ee eedends 21 A A saaie reiiA 21 A re E E ass A E 22 Replacement Parts scissura 25 Service Publications 0 ccccseceeteeeeeeeneeeeees 25 Parts Centralissa roerien 25 WEA ANNE E e 26 This appliance may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer AR WARNING This productcon
75. r puede causar lesiones graves o la muerte por quemaduras in cendio explosi n electrocuci n e intoxicaci n con mon xido de carbono 121255 01A SEGURIDAD Continuaci n Ay PELIGRO la intoxicaci n con mon xido de carbono puede resultar en la muerte Intoxicaci n con mon xido de carbono los s ntomas iniciales de la intoxicaci n con mon xido de carbono son semejantes a los de la gripe con dolores de cabeza mareos y o n usea Si usted presenta estos s ntomas es posible que el calentador no est funcio nando correctamente Respire aire fresco inmediatamente Haga que le den servicio al calentador El mon xido de carbono afecta m s a algunas personas que a otras Las m s afectadas incluyen mujeres embarazadas per sonas con enfermedades del coraz n o de los pulmones o anemia aquellas bajo la influencia del alcohol y aquellas a grandes altitudes Gas natural y propano o gas LP los gases natural y propano o gas LP son gases inodo ros Aestos gases se les agrega un agente con olor El olor le ayuda a detectar las fugas de gas Sin embargo el olor que se a ade al gas puede desvanecerse Es posible que haya gas presente aunque no haya ning n olor Aseg rese de leer y comprender todas las advertencias Conserve este manual como referencia Es su gu a para la operaci n se gura y correcta de este calentador Ay ADVERTENCIA cualquier cambio a este calentador o alos controles puede ser
76. r cable pinched or wet Broken ignitor cable Bad ignitor Piezo ignitor nut is loose 1 2 3 4 NOW Replace pilot assembly Replace pilot assembly Reconnect ignitor cable Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry Replace ignitor cable Replace ignitor Tighten nut holding piezo ignitor Nut is located inside heater cabinet at top When ignitor button is pressed in there is a spark at ODS Pilot but no ignition Gas supply tumed off or equip ment shutoff valve closed Control knob is not in pilot position Control knob not fully pressed in while pressing ignitor button Air in gas lines when in stalled Depleted gas supply pro pane LP gas ODS pilot is clogged Gas regulator setting is not correct Turn on gas supply or open equipment shutoff valve Turn control knob to pilot position Turn to PILOT IGN position Fully press in control knob while pressing ignitor button Continue holding down control knob Repeat ignit ing operation until air is removed Contact local propane LP gas company Clean ODS pilot see Cleaning page 16 or re place ODS pilot assembly Replace gas regulator Moisture condensation no ticed on windows Not enough combustion ventilation air Refer to Air for Combustion and Ventilation require ments page 5 www desatech com 121255 01A OBSE
77. rante la combusti n Hay materiales extra os entre la v lvula de control y el quemador Fugas de gas Consulte la anotaci n de advertencia al inicio de la p gina Desensamble la tuber a de gas y extraiga los materiales extra os Localice y repare todas las fugas consulte Revisi n de las conexiones de gas en la p gina 14 El calentador produce un ruido silbante cuando el quemador est encendido Hay aire en la l nea de gas Los conductos de aire en el calentador est n bloqueados El orificio del quemador est sucio o parcialmente obstruido Haga funcionar el quemador hasta que se elimine el aire de la l nea Solicite a la compa a local de gas natural o de propano o gas LP que revise la l nea de gas Respete las distancias m ni mas de instalaci n consulte la figura 4 en la p gina 8 Limpie el quemador con sulte Limpieza en la p gina 20 o reemplace el orificio del quemador 24 www desatech com 121255 01A ESPECIFICACIONES LCR18NT HDR18NT e Gas natural e 18 000 Btu h Encendido piezoel ctrico Ajuste del regulador de presi n 6 de c a e Presi n del gas de entrada pulg de agua M ximo 10 5 de c a M nimo 7 de c a e Peso promedio del calentador 10 kg 22 Ib e Peso promedio del paquete de envio 11 6 kg 25 5 Ib LCR30NT HDR30NT e Gas natural e 30 000 Btu h Encendido piezoel ctrico e Ajuste d
78. rill holes at marked locations using 9 64 drill bit 5 Replace heater onto mounting bracket 6 Place spacers between bottom mounting holes and wall anchor or drilled hole 7 Hold spacer in place with one hand With other hand insert mounting screw through bottom mounting hole and spacer Place tip of screw in opening of wall anchor or drilled hole 8 Tighten both screws until heater is firmly secured to wall Do not over tighten Note Do not replace front panel at this time Replace front panel after making gas connections and checking for leaks see page 11 Pon e Front View Wall Heater a O Qmm Spacer Side View Figure 12 Installing Bottom Mounting Screws MOUNTING HEATER TO FLOOR WITH OPTIONAL FLOOR KIT Mounting Base Feet to Heater Note A 90 elbow is required for mounting this unit and must be installed BEFORE base feet to provide proper clearance see Figure 15 page 12 1 Lay heater cabinet on its back on a table with the heater bottom overhanging table edge 2 Apply pipe joint sealant lightly to male NPT threads of elbow Hold pressure regulator with a wrench when connecting elbow Do not overtighten elbow to regulator Regulator body could be damaged 10 www desatech com 121255 01A INSTALLATION Continued 3 Align holes in base foot with mounting holes on bottom of cabinet see Figure 13 4 Secure base foot to heat
79. ro de ninguna es tructura Sit e los tanques de suministro de propano o gas LP en el exterior Este calentador no se debe instalar en un dormitorio o en un ba o Si percibe olor a gas e Cierre el suministro de gas No intente encender ning n aparato e No toque ning n interruptor el ctrico no use ning n tel fono en el edificio e Llame inmediatamente a su proveedor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas e Sino puede localizar al proveedor de gas llame al departamento de bomberos 121255 01A www desatech com 3 SEGURIDAD Continuacion 5 Siempre haga funcionar el calentador con la perilla de control de la placa en las posiciones de bloqueo 1 2 3 o 4 Nunca ponga la perilla de control entre las po siciones de bloqueo Se podr a producir una combusti n deficiente y niveles m s altos de mon xido de carbono 6 Este calentador necesita ventilaci n con aire fresco del exterior para funcionar co rrectamente Este calentador tiene un siste ma de apagado de seguridad con detecci n de agotamiento de ox geno ODS EI ODS apaga el calentador si no hay suficiente aire fresco Consulte Aire para combusti n y ventilaci n en la p gina 5 7 Mantenga limpias y libres de residuos todas las aberturas de las partes anterior e inferior del calentador Esto asegurar que haya suficiente aire para lograr una combusti n adecuada 8 Si el calentador se apaga no lo
80. roveedor de gas llame al departamento IMPORTANTE si hace funcionar el calentador donde existen impurezas en el aire se pueden producir olores Los productos de limpieza pintura solventes de pintura humo de cigarro cementos y pegamentos alfombras o textiles nuevos etc producen gases Estos gases se pueden mezclar con el aire que se utiliza para la combusti n y producir olores PROBLEMA OBSERVADO CAUSA POSIBLE REMEDIO El calentador produce olores no deseados 1 El calentador est queman do vapores provenientes de pinturas aerosoles para cabello pegamentos etc Consulte la declaraci n IMPORTANTE anterior Hay poco suministro de combustible s lo para pro pano o gas LP Fugas de gas Consulte la anotaci n de advertencia al inicio de la p gina 1 Ventile la habitaci n Deje de usar los productos que ocasionan el olor mientras el calentador est funcionando Llene el tanque de sumi nistro Localice y repare todas las fugas consulte Revisi n de las conexiones de gas en la p gina 14 Hay olora gas incluso cuando la perilla de control est en la posici n OFF apagado Fugas de gas Consulte la anotaci n de advertencia al inicio de la p gina La v lvula de control est defectuosa Localice y repare todas las fugas consulte Revisi n de las conexiones de gas en la p gina 14 Reemplace la v lvula de control Hay olor a gas du
81. s etc in the air exist may discolor walls or cause odors IMPORTANT Vent free heaters add moisture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventila tion page 5 If high humidity is experienced a dehumidifier may be used to help lower the water vapor content in the air For convenience and efficiency install heater e where there is easy access for operation inspection and service e in coldest part of room If planning to use fan locate heater near an electrical outlet CEILING 10 25 4 cm 36 Minimum 91 5 cm Minimum Right Side Minimum To Top Surface Of Carpeting i 2 5 1 cm Tile Or Other Combustible FLOOR Material 36 91 5 cm Figure 4 Mounting Clearances As Viewed From Front of Heater THERMOSTAT SENSING BULB The thermostat sensing bulb has been placed below the heater 1 Place clamp on thermostat sensing bulb as shown in Figure 5 Clamp is provided in hardware package 2 Snap clamp into upper mounting hole as shown in Figure 5 Mounting hole is located on lower left edge on back of heater Make sure the thermostat sensing bulb is point ing up Thermostat Sensing Bulb Clamp Figure 5 Attaching Thermostat Sensing Bulb 8 www desatech com 121255 01A INSTALLATION Marking Screw Locations Continued 1 Tape mo
82. s loa 18 3 4 trav s del ltimo M n orificio de cada extremo RAR adyacente Piso Calentador con 5 placas Figura 8 Distancias m nimas del soporte de montaje Instalaci n del soporte de montaje a la pared Nota los anclajes de pared los tornillos de montaje y los separadores se encuentran en el paquete de ferreter a El paquete de ferre ter a se incluye con el calentador 10 www desatech com 121255 01A INSTALACION Continuaci n M todo de fijaci n a viga de pared Para fijar el soporte de montaje a las vigas de pared 1 Perfore orificios en los lugares marcados utilizando una broca de 9 64 2 Coloque el soporte de montaje en la pared Alinee el ltimo orificio de cada extremo del soporte con los orificios que perfor en la pared 3 Inserte los tornillos de montaje en el soporte y en las vigas de pared 4 Apriete los tornillos hasta que el soporte de montaje est asegurado firmemente a las vigas de pared M todo de fijaci n a anclajes de pared Para fijar el soporte de montaje en paredes huecas el rea entre las vigas o en paredes s lidas de concreto o mamposter a 1 Perfore orificios en los lugares marcados utilizando una broca de 5 16 Para las paredes s lidas de concreto o mampos ter a perfore a una profundidad de por lo menos 2 5 cm 1 2 Doble el anclaje de pared como se mues tra en la figura 9 3 Inserte el anclaje de pared las alas pri mero
83. s see options 1 and 2 Figure 2 page 7 You can also remove door into adjoining room see option 3 Figure 2 page 7 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts www desatech com 121255 01A AIR FOR COMBUSTION AND VENTILATION Continued Ventilation Grills Into Adjoining Room Option 2 Ventilation Grills into or Adjoining Remove Room Door into Option 1 Adjoining Room Option 3 O Figure 2 Ventilation Air from Inside Building Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings one within 12 30 5 cm of the ceiling and one within 12 30 5 cm of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the attic will activate the power vent N Ventilated Outlet i Air Attic J Outlet Ar To Attic COCO To Crawl Space Inlet emm em db Air i
84. s metales se dilatan al calentarse y se contraen al enfriarse 1 Esto es normal en la mayo r a de los calentadores Si el ruido es excesivo comuni quese con una persona de servicio capacitada Se forma un residuo de polvo blanco dentro de la caja del quemador o en las paredes o muebles contiguos Cuando se calientan los vapores provenientes de los pulidores de muebles cera limpiadores de alfombras etc pueden convertirse en residuos de polvo blanco 1 Apague el calentador cuan do utilice pulidores de mue bles ceras limpiadores de alfombras o productos parecidos El calentador se apaga mien tras se est usando el ODS funciona No hay suficiente aire fresco Hay poca presi n en la linea El piloto con ODS esta par cialmente tapado 1 Abra la ventana y o la puerta para dar ventilaci n 2 Comuniquese con la com pa a local de gas natural o de propano o gas LP 3 Limpie el piloto con ODS consulte Limpieza p gi na 20 121255 01A www desatech com 23 SOLUCION DE PROBLEMAS Continuacion el edificio de bomberos Ad ADVERTENCIA si percibe olor a gas e Cierre el suministro de gas e No intente encender ning n aparato e No toque ning n interruptor el ctrico no use ning n tel fono en e Llame inmediatamente a su proveedor de gas desde el tel fono de alg n vecino Siga las instrucciones del proveedor de gas e Si no puede localizar al p
85. s natural o cerca de ste o bien usando aire comprimido 4 Revise todas las uniones del sistema de tuber a de suministro de gas Aplique en todas las uniones alg n l quido de detec ci n de fugas que no sea corrosivo La formaci n de burbujas indicar una fuga 5 Repare todas las fugas inmediatamente 6 Vuelva a conectar el calentador y la v l vula de cierre del equipo al suministro de gas Revise los niples que se volvieron a conectar para ver si hay fugas 14 www desatech com 121255 01A INSTALACION Continuaci n Realice pruebas de las presiones de 1 2 PSI 3 5 kPa o menores 1 2 4 Cierre la v lvula de cierre del equipo consulte la figura 16 Regule la presi n del sistema de tuber a de suministro ya sea abriendo la v lvula del tanque de suministro de propano o gas LP en caso que utilice este tipo de gas o bien abriendo la v lvula principal de gas que se localiza en el medidor de gas natural o cerca de ste o bien usando aire comprimido Revise todas las uniones entre el medidor de gas si usa gas natural consulte la figura 17 o entre el tanque de suminis tro de propano o gas LP si usa este tipo de gas y la v lvula de cierre del equipo consulte la figura 18 Aplique en todas las uniones alg n l quido de detecci n de fugas que no sea corrosivo La formaci n de burbujas indicar una fuga Repare todas las fugas inmediatamente V lvula de cierre del equ
86. s orificios que va perforar Retire el calentador con la base 3 En el caso de pisos alfombrados haga un peque o corte con una navaja filosa en las ubicaciones que marc antes de hacer las perforaciones Si va a montar la base en un piso de madera perfore un orificio de 31 mm 1 8 de di metro y 2 cm 3 4 de profundidad No utilice anclajes en pisos de madera Si va a instalar la base en piso de concre to perfore 3 5 cm 13 8 de profundidad en el piso con una broca para concreto de 1 4 de di metro Inserte los anclajes completamente en los orificios 4 Coloque nuevamente el calentador con las patas de la base sobre los orificios Asegure la base al piso con tornillos para madera Consulte la figura 13 CONEXI N AL SUMINISTRO DE GAS ADVERTENCIA este aparato requiere una conexi n de entra da tipo NPT rosca de tuber a nacional de 3 8 al regulador de presi n ADVERTENCIA una per sona de servicio capacitada debe conectar el calentador al suministro de gas Siga todos los c digos locales ADVERTENCIA para gas na tural nunca conecte el calenta dor a pozos de gas privados que no sean de servicio p blico Este gas se conoce com nmente como gas de pozo 12 www desatech com 121255 01A INSTALACION Continuaci n IMPORTANTE para gas natural verifique la presi n de la l nea de gas antes de conectar el calentador a la misma La presi n de la l
87. s para soluci n de problemas se listan en orden de funcionamiento PROBLEMA OBSERVADO CAUSA POSIBLE REMEDIO Cuando se presiona el bot n 1 Elelectrodo delencendidoest 1 Reemplace el conjunto de del encendido no hay chispa colocado incorrectamente piloto en el piloto con ODS 2 El electrodo del encendido 2 Reemplace el conjunto de est averiado piloto 3 El electrodo del encendido 3 Vuelva a conectar el cable no est conectado al cable del encendido del encendido 4 El cable del encendido est 4 Libere el cable del encen comprimiendo o mojado dido si alg n metal o tube r a lo est comprimiendo Mantenga seco el cable del encendido 5 El cable del encendido est 5 Reemplace el cable del roto encendido 6 Encendido defectuoso 6 Reemplace el encendido 7 La tuerca del encendido 7 Apriete la tuerca que sostie piezoel ctrico est floja ne el encendido piezoel c trico La tuerca se localiza en el interior del gabinete del calentador en la parte superior Cuando se presiona el bot n 1 El suministro de gas est 1 Abra el suministro de gas del encendido hay chispa en cerrado o la v lvula de cierre o la v lvula de cierre del el piloto con ODS pero no se del equipo est cerrada equipo enciende 2 La perilla de control no est 2 Gire la perilla de control a la en la posici n pilot piloto posici n PILOT piloto 3 La perilla de control no est 3 Gire la perilla a la posici n completamente presionada
88. superior como se muestra en la figura 5 El orificio de montaje se localiza en el borde inferior izquierdo de la parte posterior del calentador Aseg rese que el bulbo sensor de termostato est apun tando hacia arriba Bulbo sensor de termostato Abrazadera Figura 5 Instalaci n del bulbo sensor de termostato INSTALACI N DEL CALENTADOR EN LA PARED Soporte de montaje Localice el soporte de montaje en la caja del calentador Saque el soporte de montaje de la caja del calentador Figura 6 Soporte de montaje 121255 01A www desatech com 9 INSTALACION Continuaci n Desmontaje del panel anterior del calentador 1 Quite los cuatro tornillos dos de cada lado del panel anterior 2 Jale la parte inferior del panel anterior hacia adelante y luego hacia afuera 3 Retire todos los materiales de empaque restantes Panel anterior Tornillo Figura 7 Desmontaje del panel anterior del calentador M todos para fijar el soporte de montaje a la pared Use nicamente el ltimo orificio de cada extremo del soporte de montaje para fijarlo a la pared La distancia entre estos dos orificios desde el centro de ellos es de 35 6 cm 14 Fije el soporte de montaje a la pared mediante una de las dos maneras siguientes 1 Fijaci n a viga de pared 2 Fijaci n a anclajes de pared Fijaci n a viga de pared este m todo pro porciona la sujeci n m s firme Inserte
89. supplier s instructions If you cannot reach your gas supplier call the fire department Always run heater with plaque control knob at the 1 2 3 or 4 locked positions Never set control knob between locked positions Poor combustion and higher levels of carbon monoxide may result This heater needs fresh outside air ven tilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh airis available See Air for Combustion and Ventilation page 5 Keep all air openings in front and bottom of heater clear and free of debris This will insure enough air for proper combustion If heater shuts off do nat relight until you provide fresh outside air If heater keeps shutting off have it serviced Do not run heater e where flammable liquids or vapors are used or stored e under dusty conditions Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater www desatech com 3 SAFETY Continued 12 Operating heater above elevations of 4 500 feet 1 371 m could cause pilot outage 13 To prevent performance problems do not use propa
90. tapados Comun quese con la com pa a local de gas natural o de propano o gas LP Limpie los orificios del que mador consulte Limpieza en la p gina 20 o reemplace los orificios del quemador El quemador muestra llamas de retorno durante la com busti n Los orificios del quemador est n tapados o da ados El quemador est da ado El regulador de gas est defectuoso Limpie los orificios del que mador consulte Limpieza en la p gina 20 o reemplace los orificios del quemador Reemplace el quemador Reemplace el regulador de gas 22 www desatech com 121255 01A SOLUCION DE PROBLEMAS PROBLEMA OBSERVADO Continuacion CAUSA POSIBLE REMEDIO Las placas del quemador no estan al rojo vivo 1 2 La placa est da ada La presi n del gas de entra da es muy baja La perilla de control est colocada entre posiciones predeterminadas 1 Reemplace el quemador 2 Comun quese con la com pa a local de gas natural o de propano o gas LP 3 Gire la perilla de control hasta que quede fija en la posici n deseada Un poco de humo u olor duran te el funcionamiento inicial No hay suficiente aire para combusti n o ventilaci n 1 El problema desaparecer despu s de algunas horas de funcionamiento Elcalentador produce un ruido de chasquidos o golpeteos met licos justo despu s de que el quemador se enciende o se apaga Lo
91. tarlo al suministro de gas Si es as es posible que deba presionar la perilla de control durante 30 segundos o m s Esto permitir que el aire salga del sistema de gas Si es necesario continue presionando el bot n del encendido hasta que el piloto se encienda En caso que el piloto no encienda consulte la secci n Soluci n de problemas en la p gina 21 O llame a un t cnico de servicio calificado o asu proveedor de gas para que realicen las reparaciones necesarias Encienda el piloto con un f sforo hasta que se realicen las reparaciones Para encender el piloto con un f sforo consulte el Procedimiento para encendido manual en la p gina 18 Una vez que haya encendido el piloto mantenga la perilla de control presionada durante 30 segundos Despu s de los 30 segundos suelte la perilla de control www desatech com 121255 01A FUNCIONAMIENTO Continuaci n e Si al soltar la perilla de control sta no regresa a su posici n original llame a un t cnico de servicio calificado o a su proveedor de gas para que realicen las reparaciones necesarias Nota si el piloto se apaga repita los pasos 4 al 7 Espere un 1 minuto antes de encender el piloto nuevamente 9 Gire la perilla de control en sentido con trario al de las manecillas del reloj 47 gt hasta la temperatura deseada 10 Para dejar el piloto encendido y apagar s lo los quemadores gire la perilla de control en el sentido de las manecillas
92. tilice la ltima edici n del C digo Nacional del Gas Combustible ANSI Z223 1 NFPA 54 Lo puede obtener de American National Standards Institute Inc 1430 Broadway New York NY 10018 EE UU National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 EE UU Estado de Massachusetts la instalaci n la debe realizar un plomero o un instalador de gas con licencia para ejercer en el Es tado de Massachusetts Los vendedores de calentadores suple mentarios de interiores a gas natural o propano no ventilados deben suministrar al comprador una copia del 527 CMR 30 al realizar la venta En el Estado de Massachusetts est prohibido instalar aparatos de gas sin ventilaci n en dormitorios y ba os DESEMPAQUE 1 Saque el calentador de la caja 2 Retire todo el empaque de protecci n que se agreg al calentador para su env o 3 Revise el calentador para ver si hay alg n da o debido al transporte Si el calentador est da ado devu lvalo de inmediato al distribuidor a quien se lo compr IDENTIFICACI N DEL PRODUCTO Bot n del encendedor Perilla de control Resguardo de rejilla Placa Panel anterior Gabinete del calentador Figura 1 Calentador de gas sin ventilaci n 4 www desatech com 121255 01A CARACTERISTICAS DEL PRODUCTO DISPOSITIVO DE SEGURIDAD Este calentador tiene piloto con un sistema de apagado de seguridad con Sensor de agota
93. ual PAQUETE DE ENCENDIDO ELECTR NICO GA435 Para todos los modelos con encendido piezoel ctrico Proporciona un encendido del piloto m s f cil CONSEJOS PARA SERVICIO Cuando la presi n del gas de entrada sea muy baja e El piloto no permanecer encendido El quemador tendr un retraso durante el encendido El calentador no producir el calor especi ficado El suministro de propano o gas LP puede ser bajo Posiblemente piense que la presi n del gas es muy baja Si es as comun quese con el proveedor local de gas natural o de propano o gas LP V LVULA DE CIERRE DEL EQUIPO GA5010 Para todos los modelos V lvula de cierre del equipo con rosca de 1 8 tipo NPT SERVICIO TECNICO Es posible que tenga preguntas adicionales acerca de la instalaci n el funcionamiento o la soluci n de problemas De ser as p n gase en contacto con el departamento de servicio t cnico de DESA Heating Products al tel fono 1 866 672 6040 Al llamar tenga a la mano los n meros de modelo y serie de su calentador Tambi n puede visitar el sitio web de servi cio t cnico de DESA Heating Products en www desatech com 121255 01A www desatech com 25 PIEZAS MODELOS CON GABINETE LCR16PT LCR18NT LCR26PT LCR30NT HDR16PT HDR18NT HDR26PT HDR30NT 1 le NS y Consulte las 26 www desatech com 121255 01A PIEZAS Esta lista contiene las piezas reempl
94. uente a causa delexceso de pelusa proveniente de alfombras de camas de pelo de mascotas etc ADVERTENCIA si no man tiene limpias las aberturas principales del quemador se puede producir hollin y da os a la propiedad PILOTO CON ODS Y QUEMADOR Utilice una aspiradora aire a presi n o un cepillo de cerdas suaves para la limpieza ENTRADA DE AIRE AL PILOTO DEL QUEMADOR Los orificios de la entrada de aire principal permiten que la cantidad correcta de aire se mezcle con el gas Esto produce una llama de combusti n limpia Mantenga estos orificios libres de tierra polvo y pelusa Limpie estos orificios de entrada de aire antes de cada temporada de calefacci n Si los orificios de aire est n bloqueados producir n holl n Se recomienda que limpie la unidad cada tres meses de funcionamiento y que solicite que una persona de servicio capacitada inspec cione el calentador cada a o Tambi n se recomienda que mantenga el conjunto de tubo y piloto del calentador limpio y libre de polvo y suciedad Para lim piar estas piezas se recomienda usar aire comprimido a una presi n no mayor de 30 PSI Es posible que la tienda local de equipo de c mputo ferreter a o de mejoras al hogar tengan aire comprimido en latas Si utiliza aire comprimido en lata siga las instrucciones que aparecen en la misma Si no sigue las instrucciones escritas en la lata puede da ar el conjunto del piloto 1 Apague la unidad
95. unting bracket to wall where heater will be located Make sure mount INSTALLING HEATER TO WALL ing bracket is level Mounting Bracket Locate mounting bracket in heater carton Re A WARNING Maintain minimum move mounting bracket from heater carton clearances shown in Figure 8 If youcan provide greater clearanc es from floor and joining wall 2 Mark screw locations on wall see Figure 8 Note Only mark last hole on each end of Figure 6 Mounting Bracket mounting bracket Insert mounting screws Removing Front Panel Of Heater through these holes only 1 Remove the four painted screws two on 3 Remove tape and mounting bracket from each side of front panel wall 2 Pull bottom of front panel forward then out God 14 35 6 cm 3 Remove any remaining packaging materials om Nore eon ar T Min Y Front Panel 4 NX y 4 Only Insert Mounting 48 3 g Screws Through Last g Hole On Each End em A Floor 3 Plaque Heater L 16 14 35 6 cm 40 6 cm Min q n Only Insert Mounting 48 3 4 Screws Through Last 47 6 cm Min Figure 7 Removing Front Panel Of Hole On Each End Heater BRsimag Wal Methods For Attaching Mounting Bracket To Wall Floor Only use last hole on each end of mounting bracket to attach bracket to wall These two 5 Plaque Heater holes are 14 35 6 cm apart from their cen Fig
96. up plies paint paint remover cigarette smoke cements and glues new carpet or textiles etc create fumes These fumes may mix with combustion air and create odors OBSERVED PROBLEM POSSIBLE CAUSE REMEDY White powder residue form ing within burner box or on adjacent walls or furniture 1 When heated vapors from furniture polish wax carpet cleaner etc may turn into white powder residue 1 Turn heater off when us ing furniture polish wax carpet cleaners or similar products Heater shuts off in use ODS operates Not enough fresh air is available Low line pressure ODS pilot is partially clogged Open window and or door for ventilation Contact local natural or propane LP gas company Clean ODS pilot see Cleaning page 16 Heater produces unwanted odors Heater burning vapors from paint hair spray glues etc See IMPORTANT statement above Low fuel supply propane LP gas only Gas leak See Warning statement at top of page Ventilate room Stop us ing odor causing products while heater is running Refill supply tank Locate and correct all leaks see Checking Gas Con nections page 12 Gas odor even when control knob is in OFF position Gas leak See Warning statement at top of page Control valve defective Locate and correct all leaks see Checking Gas Con nections page 12 Replace control valv
97. ure 8 Mounting Bracket Clearances ters Attach mounting bracket to wall in one Attaching Mounting Bracket To Wall ofitwo ways Note Wall anchors mounting screws and spacers are in hardware package The hard ware package is provided with heater 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to Wall Stud This method pro id s the st t hold t ti Attaching To Wall Stud Method MESS Me SUOngest N9 C NSETE MOUnNUNJ FOr attaching mounting bracket to wall studs screws through mounting bracket and into wall studs 1 Drill holes at marked locations using 9 64 drill bit Attaching to Wall Anchor This method al 2 Place mounting bracket onto wall Line lows you to attach mounting bracket to hollow up last hole on each end of bracket with walls wall areas between studs or to solid holes drilled in wall walls concrete or masonry Insert mounting screws through bracket Decide which method better suits your needs h and into wall studs Either method will provide a secure hold for 4 Tighten screws until mounting bracket is the mounting bracket firmly fastened to wall studs 121255 01A www desatech com 9 INSTALLATION Continued Attaching To Wall Anchor Method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete or masonry drill at least
98. used The space in the above example is a confined space because the actual Btu Hr used is more than the maximum Btu Hr the space can sup port You must provide additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoin ing room or add ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoors See Ventilation Air From Outdoors page 7 C Install a lower Btu Hr heater if lower Btu Hr size makes room unconfined If the actual Btu Hr used is less than the maxi mum Btu Hr the space can support the space is an unconfined space You will need no additional fresh air ventilation WARNING Ifthe areain which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoin ing unconfined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 30 5 cm of the ceiling and one within 12 30 5 cm of the floor on the wall con necting the two space
99. ventilaci n Sin embargo en los edificios que tienen una construcci n inusualmente sellada tiene que proporcionar aire fresco adicional Una construcci n inusualmente sellada se define como aquella en la que a las paredes y los techos que est n ex puestos a la atm sfera exterior tienen un retardante continuo de vapor de agua con una clasificaci n de un perm 6 x 1071 kg por pa seg m o menos con aberturas selladas o con juntas y b se han instalado burletes en las ventanas y puertas que se pueden abrir y c se ha puesto sellador en reas tales como uniones alrededor de los marcos de puertas y ventanas entre las placas base y el piso entre las uniones de la pared y el techo entre los paneles de las paredes en las perforaciones para tuber a de agua l neas el ctricas y de gas y en otras aberturas Si su casa cumple con estos tres criterios debe r proporcionar aire fresco adicional Consulte Aire del exterior para ventilaci n p gina 7 Si su casa no cumple con los tres criterios anterio res vaya a Determinaci n del flujo de aire fresco para la ubicar el calentador en la p gina 6 121255 01A www desatech com 5 AIRE PARA COMBUSTION Y VENTILACION Continuaci n Espacio confinado y no confinado El C digo nacional de gas combustible ANSI Z223 1 NFPA 54 define el espacio confinado como aquel cuyo volumen es menor de 4 8 m por kW 50 pies c bicos por cada 1 000 BTU h de clasifi
100. vuelva a encender hasta que ste cuente con aire fresco del exterior Si el calentador se sigue apagando haga que lo reparen 9 No haga funcionar el calentador Donde se utilicen o almacenen l quidos o vapores inflamables e En condiciones con mucho polvo 10 No use el calentador si cualquiera de sus partes ha estado sumergida en agua Llame inmediatamente a un t cnico de servicio capacitado para que inspeccione el calen tador y para que reemplace las piezas del sistema de control o los controles de gas que hayan estado sumergidos en agua 11 Apague y desconecte el calentador y deje que se enfr e antes de darle servicio S lo una persona de servicio capacitada debe repararlo o darle servicio 12 Si el calentador se hace funcionar a altu ras superiores a 1 371 m 4 500 pies el piloto se podr a apagar 13 Para evitar problemas de rendimiento no use tanques de propano o gas LP de menos de 45 kg 100 Ib de capacidad 14 Apague el calentador antes de usar puli dores de muebles ceras limpiadores de alfombras o productos parecidos Si se ca lientan los vapores que se desprenden de estos productos pueden producir un polvo blanco dentro de la caja del calentador o en las paredes o los muebles adyacentes 15 Procure que se cumplan las distancias m nimas alrededor de las aberturas de aire C DIGOS LOCALES Instale y use el calentador cuidadosamente Siga todos los c digos locales A falta de c digos locales u

Download Pdf Manuals

image

Related Search

Related Contents

Supplemental Manuals for Digital Photographic Documentation  82-12890 USER`S - MCM Electronics  HP 15 15-f008cl  O equipamento certo para uma mistura perfeita  Sony KE-32TS2U, KE-42T2U Flat Panel Television User Manual    SCD de l`Université de Provence – Rapport d`activité 2009  Manual de Instrucciones  T360 Gun Owners Manual    