1. ae in a window pane E INSIDE 245 Ti 4 OUTSIDE fig 4 n dolby a Ri c through the wall a ad 0 l a fig 1 INSIDE 3 a A2 through the wooden base sec tion of a door or window fig 3 TEMPORARY INSTALLATION Note In both cases permanent and temporary installations make sure that the Pinguino is positio ned on level ground If necessary use the two caster stops for the front casters This installation makes it easy Suction discs may be used to Pinguino is equipped with an to use Pinguino in any room keep window or door closed adjustable window bracket If provided there is a window or you have a sash window a door it allows you to use the place the bracket on the win Pinguino immediately dow sill extend the bracket fully within the window frame and lower the window onto the bracket Insert the nozzle of the exhaust hose into the slot then connect the hose to the air conditioner bracket fig 5 SET UP INSTRUCTION For permanent installation place the Pinguino near the outlet opening in wall or window where it is meant to be used The diagram below shows the correct way to installl the exhaust hose 1 Water collects at this point 2 Bend this section 3 Bend this section fig 8
2. NO YES YES ELECTRICAL CONNECTION Check that the power supply voltage is 115 V 60 Hz Important if you need to use and extension cord please be sure to use a heavy duty extension cord minimum 14 gauge Before connecting the Pinguino to power supply make sure that all switches on the front control panel are in the OFF position Connect power cord found in storage compartment at rear of the Pinguino 8 FINAL CHECK In order to obtain the maximum performance from your air conditioner make sure that Doors and windows of room to be air conditioned are closed with the excep tion of temporary installation where a par tially opened window is necessary Shade the room as far as possible from Ensure that intake and outlet vents fig 2 direct sunlight by drawing curtains and or and 3 are not blocked lowering blinds or shutters for economical Make sure there are no sources of heat in and efficient air cooling the room SPECIAL NOTE This machine is designed to be used with or without water Maximum performance is obtained using water When used without water Pinguino will operate at about 67 cooling capacity HOW TO PREPARE WATER CONTAINER Use only clean salt free tap water The water is essential for the air cooling operation and si dischar ged in the form of steam through the exhaust outlet A container full of water lasts for a period that depends on a number of conditions
3. such as temperature humidity insulation exposure of the room number of people present etc On average it will last approximately 7 to 10 hours When the container is empty the appliance automatically changes function from water to air At the same time the quantity of air discharged from the rear hose will increase eo fig 14 After filling replace the extendable Open the water container compartment Remove the cap pull out the extenda tube screw the cap on tightly and door tip the container forwards and lift ble tube and fill the container standing return the container to its place making up to remove iton the floor sure the word FRONT is facing out During water condensation cooling function and in particularly quiet surroundings eg bedroom a slight gurgling noise may be heard This may be regarded as perfectly normal Warning Do not use water containing salt eg seawater or water treated using softening systems that utilize kitchen salt DESCRIPTION OF PINGUINO PAC 250U CONTROLS ON OFF button ON OFF pilot light 4 E EY SS eS Tiss eee bo O IO Jai EH A MY Lo LY RY Alarm pilot light __ Timer ON OFF pilot light Timer ON OFF Selecting fan Timer notches Thermostat button speed button SETTING THE TIMER The
4. OWNERS MANUAL Paouin CLASSIC PAC 250 U Portable Windowless Air Conditioner IMPORTANT NOTE MAINTENANCE NEEDS ON PAGE 14 IMPORTANT INFORMATION When using electrical appliances basic safety precautions should always be followe including the following Read all instructions To protect against fire electrical shock and personal injury do not immerse cord plug or appliance in water or other liquid Close supervision is necessary when any appliance is used by or near children Do not operate with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner Return the appliance to the nearest authorized service facility for examination repair or adjustment The use of accessory attachments or spare parts not recommended by the appliance manufacturer may result in fire electrical shock or personal injury Do not use outdoors Do not use the appliance for other than the intended use Do not place any strain on the power cord Avoid twisting and or tan gling Ensure that outlet vent of exhaust hose is kept debris clear and obstruction free Ensure that ventilation holes on the rear of the machine and front lou vers are not blocked The Pinguino should not be installed where the atmosphere could contain combustible gases Avoid using Pinguino in oily or sulphurous atmospheres or near sour ces of heat Wait at least 3 minutes before restarting after t
5. an filter and dry well before replacing Cover appliance with a polyethylene bag to prevent dust from entering You can use the polyethylene bag included into the packaging I2 fig 25 1 Disconnect plug 2 Remove tank and empty it 3 Some water may remain into the tank To avoid unpleasant odors pour two spoons of bleach into the tank 4 Drain water from collecting tray 13 PERIODIC MAINTENANCE Calcium deposits may build up on some working parts of Pinguino during operation Monthly cleaning more often in hard water areas should be done per the following procedure Unplug the machine Remove the water tank Remove drainage tube plug and empty water Replace drainage tube plug and add one quart of clean water to the collecting tray Empty 8 Fl Oz of Descaling Fluid into the collecting tray Plug in the machine and operate for about half an hour Turn off and unplug machine Drain the remaining liquid and re plug the drainage tube Refill the tank with clean water and replace in the machine Plug in and turn on the machine While the air conditioner is operating unplug the drainage tube and drain until the water looks clean Replace the drainage tube plug TROUBLESHOOTING SYMPTOMS CAUSE SOLUTION The Pinguino does not power failure function plug is disconnected insert plug ON OFF switch is off switch on The Pinguino does not function function fault w
6. arge Ib gr see rating label Data according to pending standard testing procedures subject to review by the U S Dept of Energy OPTIMUM OPERATING RANGE ROOM TEMPERATURE 70 F 90 F ROOM HUMIDITY FACTOR 50 80 RH POWER FREQUENCY 60 HZ ARRESE VOLTAGE 115V ILLUSTRATED MAIN FEATURES LIST Air outlet grid Timer cover to adjust the timer slide cover sideways Water container Castor Castor stops Water collecting tray Water container compartment door Air filter Air intake grid Exaust hose Power cable comp Manually resettable red button ILLUSTRATED ACCESSORY LIST Table 1 DESCRIPTION SUPPLIED O NODO Exhaust hose 1 ey Stopper flange 2 Caster stop 2 Descaling fluid 1 NY Window nozzle 1 EEK Adjustable window bracket 1 Suction disc 2 ACCESSORY CHECK Check that all parts listed in Table 1 are included PERMANENT INSTALLATION The Pinguino accessories include two sets of flan ges and stoppers to be mounted in different loca tions two different rooms Once installed these vents flanges are the only items needed for using Pinguino Permanent installation outlet holes must be in an exterior wall and opening diameter should not exceed 3 2 INSID OUTSIDE 3 2 i Al
7. arning light is on pag 10 Alarm light After correcting problem press reset button see pag 5 The Pinguino produces cold air but room does not maintain comfortable temperature SERVICING Timer key is in STOP position exhaust hose blocked exhaust hose twisted or bent ventilation holes on the rear of the machine or front louvers blocked window open alr exhaust hose has become disconnected thermostat set too low ir filter blocked water tank empty Dv release the TIMER key Check for obstruction of air outlet vent eliminate irregularities remove obstacles to allow proper airflow close window re insert exhaust hose set thermostat to higher num ber clean filter refill it In case of malfunction turn off and disconnect the Pinguino from power outlet and contact our Service Centre for qualified assistance toll free number 1 800 322 3848 FOR UNITED STATES ONLY ST IT SOL III LIMITED WARRANTY We warrant each DE LONGHI AIR CONDITIONER to be free from defects in material and workmanship Our obligation under this warranty is to provide one year parts and labor free from purchase date with an additional four 4 years on any part of the sealed system consisting of the compressor evaporator condenser and factory connected refrigerant tubing This warranty shall apply only if the AIR CONDITIONER is used in accordance with the factory directions which accompany it and on Alternati
8. g in thickness We therefore recommend that when starting up the appliance the thermostat be turned to maximum thick green line maximum cold When the desired temperature has been reached turn the thermostat slowly away from the maximum cooling position until the appliance switches off Leave the thermostat in this position The air conditioner is now programmed to maintain the exact temperature at all times After switching the appliance off wait at least 3 min before switching on again 10 HOW TO START UP THE CONDITIONER see control panel on the previous page Plug the appliance into the mains Select the programmed or non pro grammed mode see previous page Select the fan speed required pressing Fan speed key C AIR CONDITIONING Key A ON OFF conditioning must be released Turn the thermostat to Max Cold Press key A ON OFF ON OFF signal lamp conditioning will come on The appliance comes on If not refer to pag 14 To switch off the appliance press key A ON OFF main switch MAINTENANCE PRECAUTIONS da US During cleaning and normal maintenance operations Under no circumstances should appliance be remember to disconnect plug washed with runing water Damage could be cau sed to the electrical circuit CLEANING OF EXTERNAL HOUSING Use only mild soap and water Do no
9. gn Current AC circuit This warranty is in lieu of all other warranties and representations expressed or implied and all other obligations or liabilities on our part We do not authorize any other person or com pany to assume for us any liability in connection with the sale or use of our AIR CONDI TIONER This warranty shall not apply to assume for us any liability in connection with the sale or use of our AIR CONDITIONER This warranty shall not apply to any AIR CONDITIO NER which shall have been repaired or altered outside our factory nor shall it apply to any AIR CONDITIONER which has been subjected to misuse negligence or accidents If repairs become necessary or spare parts are needed plese write to SERVICE DE LONGHI AMERICA INC PH N 1 800 322 3848 625 WASHINGTON AVENUE CARLSTADT NJ 07072 FOR CANADA ONLY IIA DE Longhi AUNAN SUO III LIMITED WARRANTY We warrant each DE LONGHI AIR CONDITIONER to be free from defects in material and workmanship Our obligation under this warranty is to provide one year parts and labor free from purchase date with an additional four 4 years on any part of the sealed system consisting of the compressor evaporator condenser and factory connected refrigerant tubing This warranty shall apply only if the AIR CONDITIONER is used in accordance with the factory directions which accompany it and on Alternating Current AC circuit This warranty is in lieu of all other warranties and repre
10. he air conditioner has been switched off or the thermostat setting changed Before moving the air conditioner remove tank and empty water from collectiong tray see instructions for drainage at page 12 Do not place hot or heavy objects on the appliance Clean air filter every week see instructions at page 13 Important If you need to use an extension cord please be sure to use a heavy duty extension cord minimum 14 gauge SAVE THESE INSTRUCTIONS Dear user We thank you for purchasing the Pinguino air conditioner and congra tulate you on your wise choice For optimal results please read this manual carefully before installing or operating We know that the Pinguino will main tain your environment pleasingly comfortable at all times With best wishes De Longhi S p A If you have any questions about the operation or service of your Pinguino please call our toll free service number 1 800 322 3848 SPECIFICATIONS Power supply voltage V see rating label Frequency Hz 60 Cooling capacity With water Btu W 8000 2350 With air Btu W 5400 1580 Current consumption 65A Water tank capacity gall 3 2 Air flow capacity 188 35 cfm Room thermostat adjustable Dimensions width in mm 22 s1 560 height in mm 30 735 depth in mm 15 t6 390 Net weight Ib kg 90 41 Refrigerant system freon R 22 Compressor protection Overload relay Freon ch
11. programmer timer like all clocks must be set to the exact time If for example it is 4 00 p m turn the dial in a clockwise direction fol lowing the direction of the arrow until the num ber 4 is lined up with the arrow pointer the arrows indicates 4 00 p m approximately arrow pointer Note Never turn the dial in an anti clockwise direction The timer is in effect an electric clock and works only if the plug is connected to the power supply Whenever the plug is discon nected or there is a power failure the program mer stops the clock is then slow and must be re set The unit can be used in either programmed or non programmed mode PROGRAMMED MODE 1 Release B timer button 2 Set the operating times by pushing out the notches on the dial corresponding to the period required each notch represents 15 mins 3 Check that the timer indicates the correct time see instructions on setting Operating time eg from 9 to 11 a m 4 Select the desired function as shown in the chart overleaf The unit will now switch on and off each day at the selected times Note To override the programmed operating times simply press the ON OFF key NON PROGRAMMED MODE 1 B TIMER button must be pressed 2 Select the desired function as shown in the chart on the following page N B For technical reasons the temperature is not expressed in degrees but by a line increasin
12. sentations expressed or implied and all other obligations or liabilities on our part We do not authorize any other person or com pany to assume for us any liability in connection with the sale or use of our AIR CONDI TIONER This warranty shall not apply to assume for us any liability in connection with the sale or use of our AIR CONDITIONER This warranty shall not apply to any AIR CONDITIO NER which shall have been repaired or altered outside our factory nor shall it apply to any AIR CONDITIONER which has been subjected to misuse negligence or accidents If repairs become necessary or spare parts are needed please write to SERVICE DE LONGHI CANADA PH N 905 238 1313 1040 RONSA COURT L4W 3Y4 CANADA ZL AS gt a
13. t use chemical cleaners Clean with a damp cloth and dry thoroughly fig 18 with a clean dry cloth CONTROLS AT THE BEGINNING OF THE SEASON Carefully follow installa tion procedure Check for any defects in power cord and plug fig 19 CLEANING OF COLLECTING TRAY 4 Remove plug from drai nage tube located at rear of appliance and emty water into the tray for water drainage sup plied as accessory 5 When draining is fini shed replace plug of drainage tube 6 Remove sediment from the collecting tray by rubbing with a cloth 1 Open water container compartment door and remove tank 2 Keep the air conditioner working until the water level indicator light goes on 3 Switch off the air condi tione and disconnect electrical plug AIR FILTER CLEANING Maintenance of air filter Removal and replacement of air filter A clogged air filter reduces the quantity of cir Gently pull filter upwards culating air and the efficiency of the appliance Push down to replace Clean filter every week using a vacuum clea ner Remove dust witha Rinse with running vacuum cleaner water Cleaning procedure To remove dust deposited on filter use a vacuum cleaner If it is very dirty soak in lukewarm water and rinse thouroghly The temperature of the water must be kept below 104 F After washing leave filter to dry before replacing END OF SEASON OPERATIONS 5 Remove exhaust hose Cle