Home
DCS -IVH-48 Ventilation Hood User Manual
Contents
1. 127 40 5 8 34 5 8 FRONT VIEW 843fi21 SIDE VIEW Site Preparation and Installation Guidelines Site Preparation You will need to create a secure soffit structure to mount the Island Vent Hood to the ceiling We suggest using 1 1 2 by 3 1 2 wood cut to fit the installation as shown in the following pages The soffit mounting to the top of the Island Vent Hood will be 10 7 8 in length for the DCS IVH 48 and 10 3 4 for the DCS IVH 36 These dimensions allow room for a 1 2 drywall duct cover Do not deviate from these dimensions when choosing a duct cover as the soffit structure must align with the mounting holes on the Island Vent Hood You are limited to a maximum of 1 2 inch on all sides YA NOTE You will need to determine which type of duct cover will be used before installation and leave enough space around the soffit for a flush mount between the duct cover material and the top of the Island Vent Hood 4 caution When installing the ISLAND VENT HOOD directly to the ceiling adeguate structural supports are CRITICAL to secure the unit The Island Vent Hood is heavy weighing 128 LBS for the DCS IVH 48 and 94 LBS for the DCS IVH 36 Y note The soffit height will vary according to the ceiling height GENERAL INSTALLATION GUIDELINES 1 Determine the location for installation 2 Determine the centerline of the installation 3 If drywall is installed cut away enough dryw
2. controls The switch adjacent to the speed control turns the blower on off while the speed control adjusts the blower speed Turn the speed knob clockwise 10 increase and counterclockwise to decrease the blower speed Hood Lighting A single switch controls the 4 halogen lights The switch controls the brightness of the lights with Hi Off Low Use only 50w Max Halogen Narrow Flood replacement bulbs Caution Halogen lamps are constructed of a glass bulb with a pressurized internal filament tube that operates at high temperatures and could be discharged into the fixture enclosure and or surrounding environment thereby creating a risk of personal injury of fire When replacing the bulb let the bulb cool and assure that power to light has been turned off Never allow a hot bulb to come into contact with water Do Not Touch the Hood Light Bulbs when they are in use They may be hot enough to cause injury LC ELU E Halogen Light Bulb Hood LightsBlower Blower Variable Speed Contr Care And Use Cleaning the exterior Stainless Steel finish When cool the appliance can be cleaned with hot soapy water rinsed dried and buffed to a shine with a soft heavy pile cloth Always try this first as it is the mildest form of cleaning 1 Some brands of cleaners are harsher than others Read their instructions Try on a Small inconspicuous area first 2 To avoid marring the surface always rub metal finishes in the dir
3. 2B gives soffit dimensions allowing for a 1 2 inch duct cover SIDE VIEW for DCS IVH 48 SOFFIT STRUCTU The dimensions given are for a 1 2 dryw 1 1 2 x 31 2 Soffit Wood Structure 1 i 2 x 31 2 So 4 soffit brackets TOP VIEW of DCS IVH 48 3 WA to centerline measurement from screw to screw Soffit Installation Diagrams for DCS IVH 48 Island Vent Hood THE DIMENSIONS GIVEN ARE FOR A 1 2 INCH DRYWALL DUCT COVER Figure 3B below illustrates a finished soffit structure for the DCS IVH 48 Refer to page 6 on finishing the installation Solid Soffit Structure Support Bars mounted to ceiling joices Duct Cover Ceiling NOTE Duct Cover height will vary according to ceiling height these must be custom built 30 Min to cooking surface 212 Ceiling Showy Floor 843 fig 4 FRONT VIEW of DCS IVH 48 Ducting Information General When planning the path for ducting to the outside keep in mind the following guide lines Minimize use of elbows and transitions in ductwork as to maximize air flow to out side of building An efficient airflow path contributes to the overall efficiency of the Vent Hood DCS recommends the use of smooth wall ducting not flexible ductwork Transitions are required from rectangular to round ducting see transitions as shown below Duct t
4. 3 oe g 7 le 7 Y zi 97 w Ba E a MA bi ald d meg oO m 6 lyme IM lE oz THA 1 I 78 gt El 2 YE 0n Q 7 MT m x08 F L 2 Q n Wiring Diagram Warranty Information Length of Warranty One 1 Year Full parts and Labor Covers the entire product Five 5 Years Limited Switches and motor DCS will Cover All repair labor and parts found to be defective due to materials or workmanship for one full year from date of purchase Service must be provided by an Authorized Factory Service Agent during normal working hours DCS Will Not Cover Installation or start up General maintenance Shipping damage Service by an unauthorized agency v v v v Damage or repairs due to service by an unauthorized agency or the use of unauthorized parts Vv Service during other than normal working hours gt Improper installation such as improper hook up etc gt Service visit to teach you how to use the appliance correct the installation reset circuit breakers or replace home fuses gt Repairs due to other than normal household use gt Damage caused from accident abuse alteration misuse incorrect installation or installation not in accordance with local codes gt Units installed in non residential application such as day care centers bed and breakfast centers churches nursing homes restaurants hotels schools etc This warrant
5. ISLAND VENT HOOD USE AND CARE INSTALLATION INSTRUCTIONS 11 11 1 NA DCS IVH 48 0 DCS IVH 36 Dynamic Cooking Systems Inc A MESSAGE TO OUR CUSTOMERS Thank you for selecting this Dynamic Cooking Systems Professional Island Vent Hood Because of this appliance s unique features we have developed this Installation and Use Guide It contains valuable information on how to properly Operate and maintain your new appliance for years of safe and enjoyable use To help serve you better please fill out and return the Ownership Registration Card and keep this Guide handy as it will help answer questions that may arise aS you use your new vent hood For your convenience product questions can be answered by a DCS Technical Support Representative by phone 1 888 396 2665 or Fax 714 372 7003 or by mail Dynamic Cooking Systems Inc Attention Customer Service 5800 Skylab Road Huntington Beach CA 92647 DC S gt Dynamic Cooking Systems Inc Introduction Before proceeding with installation please read this installation guide and observe all safety precautions and warnings V NOTE Installation of this DCS Island Vent Hood must comply with all local codes IMPORTANT Save these instructions for the Local Electrical Inspector s use INSTALLER Please leave these instructions with the unit for the owner OWNER Please retain these instructions for future reference Table of Conte
6. UCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR TO OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILING NOR INTO ATTICS CRAWL SPACES OR GARAGES NOTE unit MUST be vented to the outside of the building IMPORTANT Refer to ducting information supplied on Pg 11 Features Island Vent Hoods DCS IVH 48 amp DCS IVH 36 The Dynamic Cooking Systems Island Vent Hood Models DCS IVH 48 DCS IVH 36 have been designed with the ultimate in household conve nience in mind Features include a high capacity variable speed blower with speed controller commercial style dishwasher safe filters easy to clean inside grease trays and four halogen lights with Hi Low light switch removable washable filters hanger rods 4 halogen lights blower on off switch blower variable speed light on off switch Planning the Installation Backdraft Damper We recommend that a backdraft damper be used in all Vent Hood installations Cold weather installations necessitate the use of a backdraft damper to minimize the flow of cold air into the room A non metallic thermal break should also be installed to mini mize conduction of outside temperatures through the ductwork Locate the thermal break as close as possible to where the ducting enters the heated portion of the house Planning the Installation Before beginning inst
7. all to expose 2 ceiling joist 1 on each side of the Hood center line 4 Create your soffit structure according to ceiling height and attach soffit plates for DCS IVH 36 or soffit brackets for DCS IVH 48 with screws to sides see the following pages for soffits and construction 5 Attach soffit structure to existing ceiling joist 6 Secure soffit with soffit braces according to model type see diagrams page 7 10 7 Attach Island Vent Hood to soffit with the six 2 inch mounting screws provided Finishing the Installation Once the Island Vent Hood has been mounted in place it will be necessary to install the electrical service All electrical work should be done by a qualified electrician and must conform to all local standards Refer to the wiring diagram on Pg 13 for proper hook up and grounding NoTE Black live White neutral Green ground Complete the installation by making ductwork connections testing unit functions and installing amp finishing drywall 6 Soffit Installation Soffit for DCS IVH 36 Island Vent Hood THE DIMENSIONS GIVEN ARE FOR A 1 2 INCH DRYWALL 1 Create a soffit structure and attach the soffit brackets as in fig ure 1A Refer to the installation guidelines on Page 6 2 Attach the soffit support bars as shown in figure 2A 3 After securing the soffit structure adequately to the ceiling joist attach the Island Vent Hood with the mounting screws provided figure 3A Refer to page 6 on f
8. allation of the Island Vent Hood and Ventilator PLAN OUT the entire installation procedure beforehand considering the following areas YA HOOD SIZE 8 LOCATION The hood should be as wide or wider than the cooking appliance with the hood being centered on the appliance Vertically the bottom of the hood should be between 30 36 above the appliance cooking surface DUCTING ducting transitions air must flow to outside use of Backdraft damper etc YA ELECTRICAL REQUIREMENTS 120 Volts 60 Hz 15 AMP Service Local Codes etc ADEQUATE MOUNTING SURFACES To support the weight of the vent hoods location of ceiling studs additional support for safe ceiling mounting etc HANDLING NOTE This Hood has been inspected prior to shipping to be free of defects Due to the weight of the Island Vent Hood and Ventilator and to prevent scratching or denting the unit we recommend the use of two installers to move place and secure the Vent Hood to avoid personal injury or damage to the Hood Specifications Product and Venting Specifications Refer to venting specifications below when ordering the duct transition to 10 30 venting specs 7 TOP VIEW of DCS IV 177 12 trol for 36 Island Vent Hood See Page 11 for Ducting Information VENT HOOD DIMENSIONS DCS IVH 48 DCS IVH 48 30 1 52 5 8 34 5 gu DCS IVH 36 DCS IVH 36
9. ape may be used at ducting joints DCS IVH 48 Requirements DCS recommends the use of 10 round ducting which provides 78 6 In 2 of sur ace area See Duct Accessories below on for ratio to 10 transition Alternate duct sizes in rectangular style may be used If a rectangular duct style is used ne ust equal at least 78 6 In 2 for best results Example 3 1 4 x 24 duct 78 In 2 Maintain consistent ducting square area as to avoid reduced air flow ie With a IVH 48 Hood connecting a 4 x13 52 In 2 to a 10 round 78 6 In 2 is not recom mended DCS IVH 36 Requirements DCS recommends the use of 7 round ducting which provides 34 7 In 2 of surface area Alternate duct sizes in rectangular style may be used If a rectangular duct style is used the duct must equal at least 34 7 In 2 for best results Duct Accessories Wall Caps and Roof Caps must have free open area equal to duct size diameter Note that a Sealed Back Draft Damper may reduce air delivery Transition for right left or rear air discharge also available 10 S 5 Jan is Vertical Duct Transition for 48 I 11 Care And Use Controls We recommend you turn your hood on before you begin cooking to establish fresh airflow After you have finished cooking let the blower run for a few minutes to clear the air and help keep the kitchen fresh and clean Blower The Blower is operated with 2
10. ection of the polish lines The cleaner will be more effective when used in the direc tion of the polish lines 3 Use only clean sponges soft cloths paper towels plastic non metal soap pads for cleaning or scouring use only soap pads with soap still in them a dry pad can scratch the surface 4 Be sure 10 rinse thoroughly and to wipe dry to avoid water marks Filters and Grease Trays Filters should be cleaned frequently in a detergent solution and are dishwasher safe Empty grease collection tray s regularly Unplug the Blower Motor before cleaning Ventilator Remove filters to access blower motor plug Vacuum blower to clean Do not immerse in water Do not allow and excessive accumulation of grease Use a mild detergent when cleaning v v v v v Do not use harsh abrasives steel wool pads or abrasive cloths GREASE TRAY Care And Use Cleaning the Grease Tray Remove filter s by gently pulling up and out The grease trays can easily be reached once the filters are removed Grease collection trays are easily accessible at the center beneath DCS IVH 48 105 17 6 the filter See illustration below for location 15 IMM cz AVIVI 018 11 OOH LINHA 0 7191 87 F 8 2 ar THM ye z 78 5 7 ABE 8 1 Z Nao ae 0 a Cc 8 u gt alg THA SZ
11. inishing the installation CREATE YOUR SOFFIT STRUCTURE ACCORDING TO THE CEILING HEIGHT THEN ATTACH IT 3 7 TO THE CEILING JOIST SCREW SUPPORT BARS 2 ON BOTH SIDES AS SHOWN Create your Soffit Struct A first and attach Soffit B s to each side with screws p tets ded AN SOFFIT ASSEMBLY ae SOFFIT BRACKETS FOR 36 ISLAND VENT HOOD i i SCREWED TO BOTH SIDES OF SOFFIT STRUCTURE Sa 843 fig 1 Nae The dimensions given are for a 1 2 drywa 36 ISLAND VENT HOOD SOFFIT MOU Soffit Installation DCS IVH 48 Island Vent Hood THE DIMENSIONS GIVEN ARE FOR A 1 2 INCH DRYWALL DUCT COVER 1 Create a soffit structure and attach the soffit brackets as illus trated in figure 1B Refer to the installation guidelines on Page 6 2 Attach the soffit support bars as shown in figure 1B ND ATTACH SOFFIT _ BRACKETS ON 4 CORNERS SOFFIT STRUCTURE HEIGHT WI ACCORDING meee wt 4 SOFFIT Ka ae BRACKETS SOFFIT ASSEMBLY FOR DCS IVH 48 The dimensions given are for a Soffit Installation Soffit for DCS IVH 48 Island Vent Hood THE DIMENSIONS GIVEN ARE FOR A 1 2 INCH DRYWALL DUCT COVER 3 After adequately securing the soffit structure to the ceiling joist attach the Island Vent Hood with the 6 mounting screws provided figure 2B and 3B shows the location of the mounting screws Figure
12. ms Inc 5800 Skylab Road Huntington Beach CA 92647 Tel 714 372 7000 Fax 714 372 7001 Parts Customer Service 888 281 5698 8 99 rev 2 Litho in USA Part No 10843
13. nts Important Safety Instructions Features Planning the Installation Specifications Site Preparation and Installation Guidelines Soffit Installation Ducting Information Care and Use Wiring Diagram Warranty Information Service Important Safety Instructions Follow These Precautions Q caution TO REDUCE THE RISK OF ELECTRICAL SHOCK OR INJURY TO PERSONS ALL VENT HOODS MUST BE INSTALLED WITH VENTILATORS THAT HAVE BEEN APPROVED FOR USE WITH THE HOOD Make up air may be necessary to prevent air flowing down chimney unsealed door window or fire place opening 0 WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING GUIDELINES A Installation and Electrical Wiring Must Be Performed By Qualified Personnel In Accordance With All Applicable Codes amp Standards Including Fire Rated Construction B To Prevent Back drafting sufficient air is needed to maintain proper combustion and safe exhausting of gases through the flue chimney of fuel burning equipment Follow the cooking equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities C Use caution when cutting or drilling into walls or ceilings as not to damage electrical wiring and other hidden utilities amp CAUTION TO RED
14. y applies to vent hoods used in residential applications it does not cover their use in commercial situations This warranty is for products purchased and retained in the 50 states of the U S A the District of Columbia and Canada This warranty applies even if you should move during the warranty period Should the appliance be sold by the Original purchaser during the warranty period the new owner continues to be protected until the expiration date of the original purchaseris warranty period This warranty gives you specific legal rights You may also have other rights which vary from state to state Service How To Obtain Service For warranty service contact your local DCS authorized service agency Be prepared to provide the Model Number Serial Number and date of installa tion and a brief description of the problem If you need assistance in locating the authorized service agency in your area please contact the DCS Consumer Service Department for an authorized service agent near you 888 281 5698 Your satisfaction is of the utmost importance to us If a problem cannot be resolved to your satisfaction please write or fax us Dynamic Cooking Systems Inc Attention Consumer Relations 5800 Skylab Road Huntington Beach CA 92647 Fax us at 714 372 7003 As product improvement is an ongoing process at DCS we reserve the right to change specifications or design without notice DECS Dynamic Cooking Syste
Download Pdf Manuals
Related Search
Related Contents
LENSTAR LS 900® - Haag 取扱説明書 Docklight Application Note: Docklight Tap Pro and Docklight Tap 485 SERVICE MANUAL Tri-Electronics GT-4000 User Manual SONY Trinitron ®Color TV - Frank`s Hospital Workshop Sony KV-34FQ75 User's Manual Guide Specifications - Missouri Department of Transportation Copyright © All rights reserved.
Failed to retrieve file