CyberPower Systems 2200VA Power Supply User Manual

image

Contents

1. Off Off On Set B p Rapid beeps indicate the battery will run out of charge eeps aie within a few minutes On Off ion Overload Please turn the UPS off and unplug at least one On Off iFlash On Off Set Bae piece of equipment from the UPS Wait 5 seconds reset p the circuit breaker and restart the UPS Lon Overload Please turn the UPS off and unplug at least one Off Off On Up aie piece of equipment from the UPS Wait 5 seconds reset p the circuit breaker and restart the UPS Surge Protection Malfunction Power surge has damaged the unit Please contact CyberPower Systems For more information visit eu cyberoowersystems com or contact CyberPower Systems B V Flight Forum 3545 5657DW Eindhoven The Netherlands Tel 31 0 40 2348170 Fax 31 0 40 2340314 E MAIL sales cyberpower eu com CyberPower Systems Inc USA 4241 12th Avenue East Suite 400 Shakopee MN 55379 U S A Tel 1 952 4039500 Fax 1 952 4030009 E MAIL sales cyberpowersystems com Entire contents copyright 2004 CyberPower Systems B V All rights reserved Reproduction in whole or in part without permission is prohibited PowerPanel and PowerPanel Plus are trademarks of CyberPower Systems USA Inc CyberPower warrants to you the original purchaser that CyberPower UPS will be free from defects in design assembly materials and workmanship for two years battery is only one year from the date of original purchase Any warranty services please contact y
2. connected to an The unit must be connected to a 220 240V AC outlet 50 60Hz outlet The battery is worn out Contact Cyber Power Systems at service cyberpower eu com Contact Cyber Power Systems at Mechanical problem service cyberpower eu com ERE Turn the UPS off and unplug at least one piece of N ie mppea ade t0 equipment Wait 10 seconds reset the circuit breaker and then turn the UPS on Batteries are discharged Allow the unit to recharge for at least 4 hours Unit has been damaged by a Contact Cyber Power Systems at surge or spike service cyberpower eu com Outlets do not provide power to equipment Connect the serial USB cable to the UPS unit and The serial USB cable is not Bennecicd an open serial port on the back of the computer You must use the cable that came with the unit PowerPanel The serial USB cable is Busness Edition connected to the wrong port Try another serial USB port of your computer or PowerPanel is f inactive all icons are gray Theuitenotorovdna batte Shut down your computer and turn the UPS off gwer p g ry Wait 10 seconds and turn the UPS back on This p i should reset the unit The serial cable is not the cable You must use the cable included with the unit for that was provided with the unit the software TECHNICAL SPECIFICATIONS Modil PR1500E PRZQOOE __ input Voltage Range Frequency Range On Battery Output Voltage Pure Sine Wave at 230Vac 7 On Battery Output Frequ
3. CyberPower eu cyberpowersystems com Professional Rack Mount UPS 1500VA 2200VA User Manual K01 1500E0C 02 SAFETY WARNINGS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate your UPS This equipment can be operated by any individuals with no previous training The socket outlet shall be installed near the equipment and easily accessible During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary When replacing the batteries use batteries of the same number and type Do not dispose of batteries in a fire the battery may explode Do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt The box should contain the following UPS Unit Rack Mount bracket x 2 Stand x2 PowerPanel Bus
4. ENT PROCEDURE 1 Remove the right side front panel 2 Remove the two retaining screws of the cable protection cover then remove the cover 3 Disconnect the black and red cable 4 Remove the four retaining screws 5 Pull the battery pack out from the unit 6 Slide a new battery pack into the unit Assemble the screws cover cable and front panel in the reverse sequence of above steps AG g REMINDER Recharge the unit for 4 8 Citta hours to ensure the UPS performs expected a runtime STORAGE First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected to the UPS to avoid battery drain To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to insure battery life If the battery remains uncharged for an extended period of time it may suffer permanent loss of capacity Block Diagram Transformer Inverter DC AC Battery Charger TROUBLE SHOOTING Possible Cause Solution The UPS does not Batteries are not fully charged E ine banery by leaving Ihe UPS plugged rf ted A PIR Contact Cyber Power Systems at Battery is slightly worn out service cyberpower eu com runtime The on off switch is designed to Turn the UPS off Wait 10 seconds and then turn prevent damage by rapidly the UPS on turning it off and on The UPS will not turn on The unit is not
5. acity DIRECTIONS TO MOUNT THE UPS IN THE RACK 1 Assemble the handlebars to the rack mount brackets ears as shown in the figures using the flat head screws M4 0 8mm provided 2 Assemble the two ears to the both sides of the UPS enclosure as shown in the figures using the flat head screws M5 0 8mm provided 3 Install the UPS at or near the bottom of the rack CAUTION Atleast two people are required when mounting the UPS in the rack due to its weight The battery pack may be removed while mounting it in the rack HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least four hours is recommended to insure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet 2 Connect the equipment to your UPS outlets The IEC IEC power cords coming with the unit are used to connect your computer and monitor to the UPS Items such as copiers laser printers vacuums space heaters or other large electrical devices should not be connected to the UPS Please make sure that the total loads of your equipments are less than the maximum total power load of your UPS 3 Connect the UPS and a wall outlet by using your PC power cord Please avoid using extension cords and adapter plugs To maintain optimal battery charge leave the UPS plugged in at
6. all times 4 Press the UPS power button to turn it on The Power On indicator will be illuminated in Green 5 Install your software and accessories To use the software simply connect the enclosed serial interface cable to the serial port on the UPS and an open serial port on the computer BASIC OPERATION FRONT PANEL AND REAR PANEL DESCRIPTION Power Switch ae k ae i Press the power button to turn the UPS ON or OFF Test Switch Press this button to perform a self test of your UPS This UPS also performs a self test A automatically when powered on After the UPS passes the test it returns to on line operation If the UPS fails the self test please recharge the battery for at least 4 hours A and perform another self test If it fails after recharging the battery please replace the battery In battery mode you can press this button to silence an audible alarm Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing clean power free of surges and spikes AVR Indicator This LED indicates that the UPS is operating in automatic voltage regulation mode When the led is illuminated continuously it indicates input over voltage and the UPS f unit bucks the voltage When the led is flashed in rotation it indicates that the UPS unit boosts input voltage Using Battery Indicator This LED illuminates during utility failure indi
7. cating that the battery is supplying a power to the battery power supplied outlets Battery Level Indicator This indicator shows a visual indication of the battery charge When battery capacity is under 20 no indicator LED will illuminate If the battery capacity is under 20 even after 8 hour charge the batteries may be worn out 7 eer ka 3 Load Level Indicators This indicator shows a visual indication of the UPS load The load indicator LED will turn orange if the load is between 80 and 100 If the load is under 20 no indicator LED will illuminate 2 amp amp ial Lt Circuit Breaker Reset for Overload Protection Resettable circuit breakers provide optimal overload protection Battery Backup and Surge Protection Outlets The UPS provides 4 battery powered and surge protected outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes Backup Power for Critical Loads The UPS provides 2 battery powered surge protected outlets for the most critical connected equipment and insures temporary uninterrupted operation of connected equipment during a power failure NOTE When the UPS is overloaded the UPS will interrupt power supply to the other 4 battery outlets and leave these 2 outlets for critical loads uninterrupted Ethernet RJ 45 Network Protection Ports These ports are the protection for your
8. computer network cables IN OUT Serial Port to PC Professional Rack Mount UPS provides two serial ports to allow connection and communication between the UPS and two computers The two serial ports allow connection and communication from the DB 9 serial or USB port on the computer to the UPS unit These interfaces are also compatible with the UPS service provided by Windows 98 Windows ME Windows 2000 Windows NT Windows XP Windows Server2003 ED Primary PC with PowerPanel Plus Installed secondary PC with PowerPanel Installed The Primary computer with PowerPanel Business Edition install ed is the computer that you will use to control the UPS and make any change to the operation of the UPS The Secondary computer with PowerPanel installed is unable to exhibit any control over the UPS When there is a power failure the Primary computer will start to shutdown after a user controlled delay Once the Primary computer shuts down the UPS will signal the secondary computer and initiate a shutdown The secondary computer will then shut down Once the secondary computer has completed its shutdown the UPS will power off BATTERY REPLACEMENT AND STORAGE CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel knowledgeable of batteries and their precautions Keep unauthorized personnel away from batteries If you have questions contact
9. ency Overload Protection On Utility Circuit Breaker On Battery internal current limiting Surge Protection and Filtering Lightning Surge Protection Yes RJ45 One In One Out Network Protection Physical Total of UPS Receptacles Maximum Dimensions Weight Kg Battery Sealed Maintenance Free Lead Acid Battery User Replaceable Typical Recharge Time Warning Diagnostics Indicators Audible Alarms Environmental Operating Temperature Operating Relative Humidity Communication PowerPanel Business edition Software Management 43 3cm 8 8cm 38 8cm N O IN 32 1 12V 7TAHx4 12V 9AHx4 Yes Hot Swappable Battery Pack 8 Hours Power On Using Battery AVR Load Level Battery Level On Battery Low Battery Overload Self test 32 F to 95 F 0 C to 35 C 0 to 95 NON CONDENSING Windows 98 ME 2000 NT XP Server 2003 Yes Yes Yes Optional Circuit Breaker On Slow off Set Off flash on Rapid of Set off flash AVR Max boost 13 of input voltage for output regulation while input voltage is from 8 to 15 under nominal AVR Max boost 26 of input voltage for output regulation while input voltage is from 15 to 26 under nominal AVR Max buck 11 of input voltage for output regulation e while input voltage is from 8 to 26 over nominal Off off On Set Utility Failure The UPS is providing battery power to the outlets Rapid Utility Failure The UPS is providing battery power
10. iness Edition Software Disk X 1 PowerPanel Software Disk X1 Serial Interface Cable DB 9 X 2 Serial Interface to USB Adapter X 1 Telephone Cable X 1 IEC to IEC Power Cord X 4 UPS User Manual PowerPanel Business Edition Software User Manual PowerPanel Software User Manual HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Insure that the equipment plugged into the battery power supplied outlets does not exceed the UPS unit s rated capacity 1500VA 1000W for PR1500E 2200VA 1600W for PR2200E If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip 2 If the power requirements of your equipment are listed in units other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The below equation only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any one time Users should expect usage requirements to be approximately 60 of below value TO ESTIMATE POWER REQUIREMENTS 1 ____ Watts W x 2 0 VA or Amps A x230 ___ VA 2 Add the totals up for all pieces of equipment and multiply this total by 0 6 to calculate actual requirements There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s cap
11. our local dealers or distributors
12. your dealer or call the number in this manual for information on battery replacement CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present the risk of electrical shock Do not dispose of batteries in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 DO NOT lay tools or other metal parts on top of battery or any battery terminals 4 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit 5 Batteries are consider HAZARDOUS WASTE and must be disposed of properly Contact your local government for more information about proper disposal and recycling of batteries 6 Turn off and unplug all connected equipment 7 Turn the UPS off and unplug it from the AC power source BATTERY REPLACEM