Home

Creda TPR2-1000W Electric Heater User Manual

image

Contents

1. 4 Raise the heater to its upright position and push the heater onto the bracket to engage the top latch Fig 2 Access to the controls The controls cover on your heater has a latch which may be locked shut if desired using a small bladed screwdriver see Fig 3 To open the cover insert the blade of the screwdriver in the small slot and rotate a quarter of a turn clockwise to disengage the latch The cover may then be hinged back towards the wall for access to the controls Operation W models Thermostat only Control of Output and Temperature see Fig 4 The isolating switch in the fixed wiring should be used to switch the product ON and OFF When ON the product will be controlled by the thermostat gt Fig 4 Thermostat Operation The heater is fitted with an adjustable thermostat enabling the room temperature to be controlled by adjusting the setting accordingly The setting represents a room temperature of approximately 5 C and may be used for protection against frost Higher temperature settings range from 1 to 6 max creating a maximum room temperature of approximately 30 C Switch on the heater and turn the thermostat knob to the position corresponding to the required temperature for the room The heater will then maintain the room temperature at the chosen level provided that the correct size of heater has been selected for the room to be heated NOTE Should your heater fail to c
2. lt gt Installation and Operating Instructions TPR II Wall Mounted Panel Convector Heaters Shelf or other obstruction 150 ml Dimensions mm Model s TPR2 750W TW TPR2 1000W TW TPR2 1250W TW TPR2 1500W TW TPR2 2000W TW Part number Watt A B 75 773401 75 773411 750 620 108 75 773402 75 773412 1000 620 108 75 773403 75 773413 1250 688 108 75 773404 75 773414 1500 688 108 75 773405 75 773415 2000 860 108 150 min A lt gt Fig 1 See Fig 2 IMPORTANT THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE Important Safety Advice When using electrical appliances basic precautions should always be followed to reduce the risk of fire electrical shock and injury to persons including the following IMPORTANT The wall brackets supplied with the appliance must be used IMPORTANT If the heater is installed in a room containing a bath or shower it must be so installed that switches and other controls cannot be touched by a person using a bath or shower Do not use outdoors Do not locate the heater immediately below a fixed socket outlet or connection box Do not cover the heater Do not place material or garments on the heater or obstruct the air circulation around the heater for instance by curtains or pushing furniture up against the heater as this could cause overheating and a fire risk NEVER cover or obstruct in any
3. protection setting to provide protection from freezing at a minimum cost 2 Use it where you need it Set the appropriate temperature on your heaters for the room they are in for example leave the thermostat on a heater in a spare bedroom on a lower setting 3 Use it when you need it Use heaters fitted with timers or linked to central controllers to turn the heating on only when you need it and automatically switch it off when you don t 4 Curtains Close your curtains at dusk to stop heat escaping through the windows 5 Windows Nearly 25 of heat loss can occur through poorly insulated frames and single glazing If you can t afford to double glaze all your windows go for the rooms you heat most 6 Treat your hot water tank give it a jacket An insulating jacket for hot water tanks only costs a few pounds and pays for itself within months Fit one that s at least 75mm 3 thick and you could save 10 15 a year 7 Water Use a shower if you have one to save time money and water Don t set the thermostat too high on your water heater 60 C 140 F is usually adequate for bathing and washing Put the plug in when running hot water in your sink leaving hot taps running is both wasteful and expensive Ensure dripping taps are repaired quickly In just one day you could waste enough water to fill a bath Other Energy Saving Tips for Around the Home 1 Lights Turn off lights whenever you
4. way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater The heater must not be covered WARNING THE SURFACES OF THIS HEATER CAN BE HOT Momentary contact with any part of the heater should not cause injury However aged or infirm persons or young children should not be left unsupervised in the vicinity of the heater unless a suitable guard is fitted This appliance is not intended for use by children or other persons without assistance or supervision if their physical sensory or mental capabilities prevent them from using it safely Children should be supervised to ensure that they do not play with the appliance Note that due care and consideration must be taken when using this heater in series with a thermal control a program controller a timer or any other device that switches on the heat automatically since a fire risk exists when the heater is accidentally covered or displaced If the supply cord is damaged it must be replaced by the manufacturer or service agent or a similarly qualified person in order to avoid a hazard Electrical WARNING THIS APPLIANCE MUST BE EARTHED The electrical installation must be carried out by a competent electrician and be in strict accordance with the current E E regulations for Electrical Equipment in Buildings The heater is fitted with a length of flexible cable type HO5VV F size 3 x 1 0mm on all models for connection to the fixed wiri
5. e hour All other segments will be ON 2 You can select as many ON periods as you like within the 24 hour day The settings will repeat every day until changed 3 To change ON and OFF times simply push in any ON segments you wish to cancel and pull out new ON segments as required Note On T models each segment on the timer represents 20 mins Setting the Time The current time is set by rotating the timer dial clockwise until the correct time is indicated opposite the datum mark Safety Overheat protection For your safety this appliance is fitted with a thermal cut out In the event that the product overheats for some reason the cut out prevents excessive temperatures on the product by cutting the power to the heater Once the heater has cooled down it will reset automatically It will continue to cycle on and off automatically until the reason for overheating is removed Cleaning Before commencing cleaning unplug the heater and allow it to cool Disconnect the electricity supply to the appliance The outside can be cleaned by wiping it over with a soft damp cloth and then dried Do not use abrasive cleaning powders or furniture polish as this can damage the surface finish To release heater from the wall bracket for cleaning or redecoration depress latch on both brackets see Fig 2 and hinge forward After Sales Service Your product is guaranteed for two years from the date of purcha
6. leave a room for more than ten minutes Use low energy bulbs wherever you can as they use less than a quarter of the electricity used by ordinary light bulbs and last ten times longer 2 Cooking Use the right size pan for the food and cooker hob Keep saucepan lids on this enables you to turn down the heat EMC EN55014 EN60555 2 and EN60555 3 which cover the essential requirements of EEC Directives 73 23 and 89 336 C The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility Applied Energy Products Ltd UK customer help line Morley Way Customer Services Tel 44 0 8709 000430 Peterborough Cambridgeshire Fax 44 0 1733 310606 PE2 9JJ e mail technical services applied energy com INCPUKP5RG Issue 0
7. ng of the premises through a suitable connection box positioned adjacent to the heater A means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules Supplementary Earth Bonding Should Equipotential Earth Bonding be required the earthing conductor in the supply cord is deemed to provide the supplementary bonding connection see Regulation 547 03 05 16 Edition I E E Wiring Regulations General The TPR Convector is designed for wall mounting on the wall brackets supplied It should only be operated when in the upright position as shown All models are protected to IP24 standard Models TPR2 W are fitted with a thermostat only Models TPR2 TW are fitted with a thermostat and a 24 hour timer Before connecting the heater check that the supply voltage is the same as that stated on the heater Wall Mounting IMPORTANT The wall brackets supplied with the appliance must be used The heater should be positioned observing the minimum clearances stated around the heater see Fig 1 DO NOT locate the heater immediately below a fixed socket outlet or connection box 1 Remove wall mounting bracket from the back of the heater by depressing the spring latch at the top of each bracket see Fig 2 2 Fix the wall bracket securely to the wall through the four screw holes provided 3 Present the heater to the wall bracket and engage lower slots in the back with bracket
8. ome on when the thermostat knob is at a low setting this may be due to the room temperature being higher than the thermostat setting Operation TW Models Thermostat and Timer Control of Output and Temperature see Fig 5 The slide switch on the timer unit controls the electricity supply to the heating elements on TW models Fig 5 Thermostat Operation see above Using the Timer The heater must be connected to the electricity supply for the timer to operate Set the timer by rotating the dial clockwise until the correct time of day is indicated opposite the datum mark located at centre front of the timer see Fig 5 OFF Position Set the timer switch to O position The timer operates but the heater will not output any heat as the electricity supply to the heating elements has been disconnected Manual Operation Set the timer switch to w position The heater will now operate continuously under the control of the thermostat see Thermostat Operation above Automatic Operation Set the timer switch to position The panel will now operate during set ON periods under the control of the thermostat To set the timer s ON and OFF periods 1 Using your finger tip or the tip of gt a pencil push in as many segments as necessary around the dial according to the times you don t hes require heat see Fig 6 Each Bae segment pushed in switches the fo J heater OFF for that part of th
9. se Within this period we undertake to repair or exchange this product free of charge provided it has been installed and operated in accordance with these instructions Your rights under this guarantee are additional to your statutory rights which in turn are not affected by this guarantee Should you require after sales service you should contact our customer services help desk on 44 0 8709 000430 It would assist us if you can quote the model number series date of purchase and nature of the fault at the time of your call The customer services help desk will also be able to advise you should you need to purchase any spares Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service Please retain your receipt as proof of purchase Energy Saving Tips The energy we use to heat light and power our homes contributes over a quarter of the UK s carbon emissions the principle contributor to climate change Around half the energy used in the home is for heating and hot water so using your heating system efficiently will not only help the environment but also save you money Energy efficiency tips for heating and hot water 1 Don t set the temperature too high By reducing the thermostat setting by just 1 C can reduce your energy use by as much as 10 And if you re going away for the winter leave the thermostat on the frost

Download Pdf Manuals

image

Related Search

Related Contents

  KFE10003-P - Cooper Industries  Módulo de Control EasyTronic  

Copyright © All rights reserved.