Home

Crate Amplifiers BFX-220H Stereo Amplifier User Manual

image

Contents

1. The SELFTEST IS ON ON BATTERY SELFTEST screen indicates the on battery selftest is active with the unit internally switched to derive power from the internal battery pack which should already be connected within the unit The BATT IN USE LED is also lit during this test SELFTEST IS ON ON BATTERY SELFTEST Screen SELFTEST IS ON ON BATTERY SELFTEST The SELFTEST RESULT TEST HAS PASSED screen indicates the selftest ran successfully to completion If the message TEST HAS FAILED is displayed please contact Crestron Technical Support SELFTEST RESULT TEST HAS PASSED Screen SELFTEST RESULT TEST HAS PASSED The DATAPORT USB screen indicates whether the USB cable is connected or disconnected In the example screen below the USB cable is not connected DATAPORT USB Screen DATAPORT USB REMOVED During the selftest the unit will also test to determine if an optional external battery pack available from APC is connected If no external battery pack is connected to the unit the message NO EXTERNAL BATTERY CONNECTED will be displayed as shown below NO EXTERNAL BATTERY CONNECTED Screen NO EXTERNAL BATTERY CONNECTED Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 23 Uninterruptible Power Supply Crestron CEN UPS1250 Status and Informational Screens The following paragra
2. Voltage Regulation Performs voltage boost or trim to maintain 120 V nominal output Maximum Output Current 12 Amps per outlet 12 Amps total Power Requirements Input Voltage 92 to 142 Volts AC 120 Volts nominal Input Frequency 47 to 63 Hz Maximum Input Current 12 Amps when fed from 15 Amp circuit Continued on following page Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 3 CEN UPS1250 Specifications Continued Uninterruptible Power Supply Crestron CEN UPS1250 SPECIFICATION DETAILS Battery Internal Battery Backup Runtime Recharging Time Battery Life Ethernet Alarm Minimum 2 Series Control System Update File Environmental Temperature Humidity Heat Dissipation Enclosure Chassis Cooling Faceplate Mounting Dimensions Height Width Depth Weight approximate Included Accessories CEN UPS1250 BTP 4 12 Volt 9 Ah maintenance free sealed lead acid w suspended electrolyte Crestron model CEN UPS1250 BTP included 12 minutes half load 625 W 2 7 minutes full load 1250 W 8 hours typical to 90 capacity following a discharge to shutdown half load 2 to 5 years under normal use 10BaseT 100BaseTX auto switching auto negotiating auto discovery full half duplex TCP IP UDP IP CIP SNMP 128 bit SSL encryption IEEE 802 3U compliant Audible alarm indicates when in backup mode when battery is low an
3. WARNING Failure to install the battery retaining bar can be hazardous to the installer 5 Install the front bezel by aligning the four pins located on the back side of the bezel with the holes in the left and right sides of the front of the unit Gently push the front bezel into place Hardware Hookup WARNING Do not make telephone cable Ethernet antenna electrical or ground system connections during a lightning storm Failure to comply may result in personal injury or death Connect the Device Due to the unique filtering provided by the CEN UPS1250 Crestron recommends that you connect the AV components as labelled on the rear panel of the unit To ensure ground loops are eliminated and to ensure there is no audible hum in your speaker system ground all AV components to the ground binding post marked G located on the rear panel Make the necessary connections as called out in the illustration that follows this paragraph Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 15 Uninterruptible Power Supply Crestron CEN UPS1250 When making connections to the CEN UPS1250 consider that the included AC cable cannot be extended Hardware Connections for the CEN UPS1250 SATELLITE IN FROM CABLE OR ANTENNA SATELLITE OUT TO TV RECEIVER OR MODEM CABLE IN CABLE OUT FROM CABLE OR TO TV RECEIVER BANK 1 ANTENNA OR MODEM
4. DIGITAL DEVICES parks TA TO CONTROL SYSTEMS MAIN POWER POWER SUPPLIES EXTERNAL BATTERY INPUT TOUCHPANELS AND FOR OPTIONAL MEDIA SERVERS BATTERY SOLD BY APC GROUND BANK 2 DISPLAYS TO LCD DISPLAYS PLASMA DISPLAYS AND PROJECTORS BANK 3 BANK 4 SERVICE PORT ENV PROBE COMPUTER ANALOG DEVICES HI CURRENT FOR FACTORY TOPC FROM EXTERNAL TO ADAGIO DEVICES CONFIGURATION TEMPERATURE RH CONTROL TO ONLY SENSOR SYSTEMS AND AMPLIFIERS TUNERS TELCO IN TELCO OUT LAN FROM TO TELEPHONE 10 100 BASE T TELEPHONE LINE OR MODEM ETHERNET TO LAN Ground Wire Connections Proper grounding is required Connect the ground from the CEN UPS1250 to earth ground Refer to the grounding diagram in the front of this manual 16 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply Programming Software Have a question or comment about Crestron software Answers to frequently asked questions FAQs can be viewed in the Online Help section of the Crestron website To post a question or view questions you have submitted to Crestron s True Blue Support log in at http support crestron com First time users will need to establish a user account Earliest Version Software Requirements for the PC NOTE Crestron recommends that you use the latest software to take a
5. CRESTRON Litited MW trantg Eed 33 Operations amp Installation Guide DOC 6635A Contents e i Crestron CEN UPS1250 Uninterruptible Power Supply Uninterruptible Power Supply CEN UPS1250 Introduction Features and Functions UPS and power conditioning Engineered by APC 2 Series control system integration Centralized management via RoomView software Battery backup and power control management Surge protection for power line coax and telco Isolated EMI and RFI noise filtering Automatic voltage regulation Built in environmental monitoring Onboard timestamp logging 19 four post EIA rack mountable Uninterruptible Power Supply The CEN UPS1250 is a 1250 Watt 120 Volt uninterruptible power supply and power conditioner Engineered by APC specifically for Crestron Designed to protect Crestron control systems media servers video displays and other devices the CEN UPS1250 employs pure sine wave battery backup to maintain continuous operation of critical components whenever power is disrupted Remote monitoring and control through Crestron s award winning RoomView software and full 2 Series control system integration deliver a comprehensive power management and protection solution that is an integral part of the complete Crestron control network Pure Sine Wave Battery Backup Any unexpected shutdown due to the sudden loss of power will certainly disrupt workflow and stop a presentation dead in it
6. SOURCE BATTERY EST RUNTIME 118MIN The EST RUNTIME XHRS FUEL XXX screen displays the estimated runtime as EST RUNTIME as well as the FUEL capacity of the internal battery pack as a percentage based on the total load connected to the device If the estimated runtime is less than one hour the EST RUNTIME will show in minutes EST RUNTIME XHRS FUEL XXX Screen EST RUNTIME 2HRS FUEL 100 The SYSTEM LOAD XXXW LOAD XXX screen displays the value load of the connected equipment in Watts and as a percentage of the total allowable load 24 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply connected to the unit Loads of less than 5 of rates load 63 Watts will be displayed as lt 5 SYSTEM LOAD XXXW LOAD XXX Screen SYSTEM LOAD lt 63W LOAD lt 5 The INPUT VOLTAGE XXXV OUTPUT VOLTAGE XXXV screen displays the actual input utility voltage level as well as the actual voltage level being output to the connected devices NOTE As shown in the illustration below at times the voltage values on the screen may not match This may be because separate circuits are used to make these voltage measurements and there is a time delay between the two circ
7. type of heat source Ventilation Do not install this device in an area where the device s vents provided for cooling purposes may become blocked and impede air flow Power Ensure this device is connected to a properly grounded AC power source Further ensure the device is plugged into a source that provides the required 120 VAC Do not use a plug adapter to defeat the AC plug ground pin Polarization This device has a polarized AC line plug and one blade is wider than the other This plug will only fit into the wall outlet in one orientation which is a safety feature Do not remove the round grounding pin or use an adapter that defeats this safety feature Power Cord Ensure power cords are routed in a manner that will ensure they are not pinched frayed or stepped on After connecting other devices to this device do not push the rear of the device up against any surface wall or shelving unit This can cause power cords to bend excessively which can break the strands of wire inside the cord Antenna Grounding Although this device provides protection against electrical surges if you are connecting an outside antenna or cable system to this device ensure the antenna or cable system is grounded to provide additional protection against voltage surges and static discharges in accordance with Section 810 of the National Electric Code ANSI NFPA No 70 and as shown in the illustration on the following page Operations amp Insta
8. CEN UPS1250 MODEL S N Screen MODEL CEN UPS 1250 S N PB0707130791 The ENV TEMPERATURE screen displays room temperature in both Celsius and Fahrenheit when the included temperature RH sensor is connected to the unit The values displayed may be rounded ENV TEMPERATURE Screen ENV TEMPERATURE 24 50C 76 0F The R HUMIDITY screen displays the relative humidity when the included temperature RH sensor is connected to the unit R HUMIDITY Screen R HUMIDITY NOT AVAIL Setup Screens You can use the front panel SETUP and up down arrow buttons to configure turn on or off various functions provided by each CEN UPS1250 unit When you press the SETUP button the unit functions are displayed in the following order 1 Audible Alarm 2 Sensitivity 3 Display Dimmer A LED Dimmer 5 Go To Battery If lt XX Volts 6 Go To Battery If gt XX Volts 7 Outlet Delay1 8 Outlet Delay2 9 Low Battery Warning 26 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply 10 Battery Replacement Date 11 Do Quick Selftest 12 Do Runtime Calculation 13 Display Beep Test 14 Screen Saver On Off 15 Reset To Default AUDIBLE ALARM setting When the alarm is set to ON it indicates an abnormal condition with the power or unit It provides an audible tone beep wheneve
9. FEstablish communication with the CEN UPS1250 and display the System Info window e Select Functions Firmware to upgrade the CEN UPS1250 firmware Program Checks In Crestron Toolbox display the System Info window click the D icon and select the Functions menu to display actions that can be performed on the CEN UPS1250 Be sure to use the Crestron Toolbox to create the CEN UPS1250 IP table e Select Functions IP Table Setup e Add modify or delete entries in the IP table The CEN UPS1250 can have only one IP table entry e A defined IP table can be saved to a file or sent to the device Edit the control system s IP table to include an entry for the CEN UPS1250 The entry should list the CEN UPS1250 s IP ID specified on the CEN UPS1250 s IP table and the internal gateway IP address 127 0 0 1 Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 21 Uninterruptible Power Supply Crestron CEN UPS1250 Operation Performing the System Test Before connecting equipment to the CEN UPS1250 ensure the unit is functional by connecting the AC power cord provided with the unit to the AC power connector on the rear panel and then to an AC outlet Also ensure the internal battery is connected Press the front panel power switch Once power is applied to the unit the display provides the information screens shown below and defined in the accompanying paragraphs The CRES
10. POWER INPUT power cord included FER 27 WIRING FAULT LED 1 red Indicates a missing ground overloaded neutral or reversed polarity at the line power input 1 The unit does not have to be powered on for batteries to recharge 2 American Power Conversion Corp APC W Kingston Rhode Island US Website www apc com 3 To determine which is pin 1 on the cable hold the cable so that the end of the eight pin modular jack is facing away from you with the clip down and copper side up Pin 1 is on the far left CAUTION When resetting the Circuit Breaker push the button in quickly and release the button Do not hold the Circuit Breaker button in Failure to comply may result in equipment damage Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 9 Uninterruptible Power Suppl Crestron CEN UPS1250 Industry Compliance This unit has been manufactured to comply with the following Standards for Safety in the United States Canada and Mexico NOTE This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are de
11. dimmer is set to OFF the screen will turn back on momentarily when there is a significant change in system status such as a power outage or a low battery condition Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 27 Uninterruptible Power Supply Crestron CEN UPS1250 DISPLAY DIMMER Screen DISPLAY DIMMER HIGH PRESS TW TO CHANGE LED DIMMER setting This screen lets you set a brightness level of HIGH LOW or OFF for the front panel LED indicators Press the up down arrow buttons to set the brightness level of the LEDs LED DIMMER Screen LED DIMMER HIGH PRESS TW TO CHANGE GO TO BAT IF lt XXXV setting This setting allows you to set a low voltage threshold for the unit which will force it to switch to power from the internal battery pack when the threshold is reached Settings range from 92 to 100 Volts GOTO BAT IF lt XXV Screen GOTO BAT IF lt 100V PRESS TW TO CHANGE GO TO BAT IF gt XXXV setting This setting allows you to set a high voltage threshold for the unit which will force it to switch to power from the internal battery pack when the threshold is reached Settings range from 134 to 142 Volts GOTO BAT IF gt XXV Screen GOTO BAT IF gt 134V PRESS TW TO CHANGE OUTLET DELAY 1 and OUTLET DELAY setting These settings let you define a time delay 0 to 10 seconds for when the u
12. on your CEN UPS1250 CEN UPS1250 Front View BATT IN USE LOW BATT ON UNE Ge a Le AC Pap OK DELAY AMP e fo a FILTERING REGULATING OVERLOAD CEN UPS1250 CEN UPS1250 Rear View 3 CABLE C KO Oi meai Se BREAKER G SATELLITE ei O l Ch INPUT 120V 47 63 12A NA ENV wring PROBE FAULT SERVICE PORT h DEV di CRESTRON iECTRONICS inc ma Q SC SE Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 5 Uninterruptible Power Suppl Crestron CEN UPS1250 CEN UPS1250 Overall Dimensions Front and Top Views 1 2 03 ae 5 SC 2 ee D IOUS 19 11 in 48 53 cm 5 54 in e ie A 14 06 cm ES G E e GAN 44 9 10 Dn 12 D 17 02 in A 19 73 in 50 10 cm 6 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Suppl CEN UPS1250 Overall Dimensions Rear View aa Say E o LE amp i Connectors Controls amp Indicators CONNECTORS DESCRIPTION CONTROLS amp INDICATORS 1 ON LINE LED 1 green Indicates a working connection to the control system 2 BATT IN USE LED 1 red Indicates output power is being fed from battery backup 3 STATUS BUTTON 1 Seq
13. Crestron CEN UPS1250 Uninterruptible Power Supply Operations amp Installation Guide CRESTRON This document was prepared and written by the Technical Documentation department at EC CRESTRON Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2008 Crestron Electronics Inc Crestron CEN UPS1250 Uninterruptible Power Supply Safety Information Read this manual Read all of the safety and operating instructions before installing and operating this device Keep this manual Retain this manual and all of the safety information that came with this device Warnings Comply with all warnings presented in this manual as well as any warnings found on the device Follow instructions Follow all instructions that pertain to operating and using this device Cleaning Shut off and unplug this device from the wall outlet and disconnect the battery before cleaning Use a soft damp cloth for cleaning Do not use liquid or aerosol cleaners NOTE Any equipment connected to this device will not be powered or protected from uninterrupted service during this process Water and Moisture Do not use this product near any source of water or in an environment where the relative humidity may exceed 95 non condensing Placement Do not install this device on an unsteady surface Do not install this device on any
14. E Sege 11 tere leegen r Ee 11 Identity oa e lt 3 260 oaet cS est Secchi ters loatees Ee Dest 11 Supplied Hardware 11 EE ee EE 11 Hardware Hookup csccescceseeeseceecseeeseeeneesceeeeeeseenecensecaecnaecaecaaecseeeaeeeaeeeneenneeaes 15 Programming Software 17 Earliest Version Software Requirements for the PC o eee eeeeseeeeesecneeeecneeeeeeeeneees 17 Programming with Crestron Svstemb ulder 17 Programming with SIMPL Windows ccceescesscsseceseceecesecenecseensecaeceeeeeeaeeeseeses 17 Example Program ccccesccescceseceseeececseecseecaeeeseeseeeeensceesecnseceaecaecaecaecaeceeeeeeneeees 19 Uploading and Uperadumng 20 Establishing Commumnteaton 20 Programs and Firmware ic cc sc sescsecessengescecetcessecestesctecsecseedessvaceccdecsceiee ii 21 Program Cheeks sscseces sec cence EENEG tea RR 21 Oper atin ENEE EENS EENS EEN 22 Performing the System Test 0 s cccs ccsavadisgecdecieetis ied sec in i ai 22 Status and Informational Screens cccecceesseeseesseeeeeeeeceseceeecaeecaeeeseeeseeeeeeneeeeeeneees 24 Setup SCreens E 26 Problem Solving ennienni inani E E E E EE E E e EE ea 31 Troubleshooting 22000 31 R ference D c ments i eu Oe E REE 32 F rther Ing ie Seann a EE ee ee 32 Future Update S onenn e O A E E E E 32 Return and Warranty POCIE Siessen reos aE E O T AA eEEeeE 33 Merchandise Returns Repair Service c ceecceeeeceeseeesceeeceseceseceseenaeeeecaeeeeeeneeees 33
15. Guide Doc 6052 which is available for download from the Crestron website www crestron com manuals Identity Code The IP ID is set within the CEN UPS1250 s table using Crestron Toolbox For information on setting an IP table refer to the Crestron Toolbox help file The IP IDs of multiple CEN UPS1250 devices in the same system must be unique When setting the IP ID consider the following e The IP ID of each unit must match an IP ID specified in the SIMPL Windows program e Each device using IP to communicate with a control system must have a unique IP ID Supplied Hardware The hardware supplied with the CEN UPS1250 is listed in the following table Supplied Hardware for the CEN UPS1250 DESCRIPTION PART NUMBER QUANTITY Left Rail Assembly 2020250 1 Right Rail Assembly 2020251 1 10 32 x 1 2 Pan Head Phillips Screw 2020255 10 10 32 x 1 2 Ornamental Screw 2020254 6 8 32 x 3 8 Pan Head Phillips Screw 2020252 4 10 24 x 3 8 Pan Head Phillips Screw 2020256 8 Cleat 2 Formed 2020257 2 Rack Mounting Ear 3U Modified 2020253 2 Installation The CEN UPS1250 may be installed on a flat solid surface or rack mounted Proper placement of the CEN UPS1250 should be accomplished in accordance with the following procedures WARNING The CEN UPS1250 weighs 62 pounds 28 12 kg and we recommend that two people lift the unit If you remove the battery as described on the following
16. NOTE The unit circuit breaker is rated for 15 Amps however the National Electrical Code NEC dictates that any particular home circuit should not be loaded to more than 80 of its rating Loss of Improper Check that all ground connections have functionality grounding been made properly due to electrostatic discharge Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 31 Uninterruptible Power Supply Crestron CEN UPS1250 Reference Documents The latest version of all documents mentioned within the guide can be obtained from the Crestron website www crestron com manuals This link will provide a list of product manuals arranged in alphabetical order by model number List of Related Reference Documents DOCUMENT TITLE Crestron e Control Reference Guide Further Inquiries If you cannot locate specific information or have questions after reviewing this guide please take advantage of Crestron s award winning customer service team by calling the Crestron corporate headquarters at 1 888 CRESTRON 1 888 273 7876 For assistance in your local time zone refer to the Crestron website www crestron com offices for a listing of Crestron worldwide offices You can also log onto the online help section of the Crestron website www crestron com onlinehelp to ask questions about Crestron products First time users will need to establish a user account to fu
17. SATELLITE CH 3 IN jl e CIRCUIT BREAKER BUTTON G SERVICE PORT FS Kai 1 green Indicates the EMI and RFI noise reduction circuit is active BANK 1 DIGITAL DEVICES 6 NEMA 5 15R female Grounded AC power outlets switched Includes noise filtering and protection for digital devices such as control systems power supplies touchpanels and media servers BANK 2 DISPLAYS 2 NEMA 5 15R female Grounded AC power outlets switched Includes noise filtering and protection for display devices such as LCDs plasmas and projectors BANK 3 ANALOG DEVICES 2 NEMA 5 15R female Grounded AC power outlets delay switched Delayed turn on adjustable from 0 to 10 seconds Includes noise filtering and protection for analog devices such as Adagio control systems and tuners BANK 4 HI CURRENT DEVICES 2 NEMA 5 15R female Grounded AC power outlets delay switched Delayed turn on adjustable from 0 to 10 seconds Includes noise filtering and protection for high current devices such as amplifiers 1 Connector for optional external battery sold by APC IN 1 F type coaxial female Coaxial cable or antenna source connection OUT 1 F type coaxial female protected TV receiver or modem device connection IN 1 F type coaxial female Coaxial cable or antenna source connection OUT 1 F type coaxial female protected TV receiver or modem device connection Disrupts pow
18. Screws 8 10 24 X 3 8 2020256 A Rack Mounting Ears 2 2020253 YS screws 4 8 32 X 3 8 2020252 d Le S Screws 6 10 32 X L i 2020254 NOTE When sliding assembled unit on to rack mounting rails ensure the cleats properly align with top and bottom inside groove of rails as shown in the illustration below Aligning Cleats with Rack Mounting Rails 14 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply Inserting and Connecting the The CEN UPS1250 is shipped with the internal battery pack disconnected The front Battery bezel of the unit is also not attached to the unit when it is shipped This procedure is for connecting the battery when the front bezel has been prematurely installed onto the chassis Perform the following steps to connect the internal battery pack 1 Grasp the front panel at the sides and pull the front bezel from the unit 2 Remove the battery retaining bar after loosening the thumbscrew that holds it in place refer to illustration below 3 Push the battery wire connector into the hole located to the left of the battery pack Ensure it is secure by gently pulling on the wire to be certain it is attached to the connector Battery Wire Connection Battery Retaining Bar pe 9 4 Install the battery retaining bar and tighten the thumb screw to secure it in position
19. TRON CEN UPS1250 screen indicates the unit has power and is functioning CRESTRON CEN UPS1250 Screen CRESTRON CEN UPS1250 The POWER CONDITIONER WITH BATTERY BACKUP screen indicates the proper firmware was installed for the model purchased POWER CONDITIONER WITH BATTERY BACKUP Screen POWER CONDITIONER WITH BATTERY BACKUP The DELAYED OUTLET1 0N DELAYED OUTLET2 OFF screen indicates power is available to the devices connected to the rear panel outlets marked BANK 3 It also shows that power is not yet available to the devices connected to the rear panel outlets marked BANK 4 Power to the BANK 4 devices will be available after the factory preset delay five seconds has elapsed Refer to Setup Screens which starts on page 26 to change the delay period Once power is available for BANK 4 devices the screen will change to DELAYED OUTLETS2 ON and the DELAY AMP LED will be lit DELAYED OUTLETI ON DELAYED OUTLET2 OFF Screen DELAYED OUTLET1 ON DELAYED OUTLET2 OFF The SELFTEST IS ON ON LINE SELFTEST screen indicates the selftest is on and the on line selftest is active This selftest is conducted using utility power 22 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply SELFTEST IS ON ON LINE SELFTEST Screen SELFTEST IS ON ON LINE SELFTEST
20. UPS1250 in the Device Library E Crestron Devices DvcLib 495 Control Systems Ces CN Ethernet Control Modules Ethernet Audio Modules LC Ethernet based Cresnet Network Expansion LC Ethernet based Crestron Software Applications Sy Ethernet UO Control ZS CMCM ZS ceNn I0 ZS cen upsi250 5 Ethernet Intersystem Device Communication SE Wireless Receivers Wireless Remotes User Devices e The system tree of the control system displays the device in the appropriate slot with a default IP ID as shown in the following illustration C2Net Device Slot 8 PROZ Slot 1 Empty C2Y Card Slot Slot 2 Empty C2 Card Slot Slot 3 Empty C2 Card Slot HB Slot 4 c21 com RE Slot 5 C2I IR8 HB Slot 6 C21 108 RE Slot 7 C21 Rv8 BB Slot 8 C2ENET 2 IP ID 03 CEN UPS1250 a ES Slot 9 C2Net Device RE Slot 10 C21 PRO2 LCDPANEL e Additional CEN UPS 1250 devices are assigned different IP ID numbers as they are added e If necessary double click a device to open the Device Settings window and change the IP ID as shown in the following figure 18 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply CEN UPS1250 Device Settings Window Device Settings Crestron CEN UPS1250 Connection Sheet Ethernet Upload Address Device Info Device Name IP Net Ad
21. ain any user serviceable components Removing the cover from this device may present a shock hazard and or may void the warranty Damage Requiring Service If any damage occurs to this device immediately disconnect unplug the AC power cord from the wall outlet Do not use the Power switch or disconnect the AC power cord from the connector on the rear of the device to disconnect power Notify Crestron Technical Support or customer Service at once Replacement Parts None of the components in this device can or should be removed or replaced unless it is by a Crestron qualified technician Periodic Inspection Inspect the line cords telephone data cords and DSS CATV coaxial cables connected to this device to ensure they are fully inserted or attached Example of Antenna Grounding Per National Electric Code NEC Ground Clamp RE Antenna Lead in Wire Antenna Discharge Unit Grounding Conductors Ground Clamp Electric Service Equipment Power Service Grounding Electrode System ii e Safety Information Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply Contents Safety Fleien geesde nett Ded sce S weet Eer enee i Uninterruptible Power Supply CEN UPS1250 1 lors ele EE 1 Features and Functions eise detect Ae Aap eateries 1 e EE e 3 Physical Description sennie eei andre ohana ian AC 5 Industry Compliance c g ee EES ae Reade eee eee Bene 10 EUR engt eege BE
22. d when overloaded Version 3 155 1240 or later 32 to 104 F 0 to 40 C 10 to 90 RH non condensing 100 BTU Hr Steel black matte powder coat finish Microprocessor controlled ultra quiet rear facing fan vented sides Extruded aluminum black matte powder coat finish with polycarbonate label overlay Freestanding or 3U 19 rack mountable rack must be four post type up to 28 maximum depth removable feet and rack mount kit included 5 21 in 13 22 cm without feet 5 54 in 14 06 cm with feet 17 02 in 43 22 cm without ears 19 11 in 48 53 cm with ears 19 73 in 50 10 cm 62 Ibs 28 12 kg Internal Battery Pack The latest software versions can be obtained from the Crestron website Refer to the NOTE following these footnotes Crestron 2 Series control systems include the AV2 and PRO2 Consult the latest Crestron Product Catalog for a complete list of 2 Series control systems NOTE Crestron software and any files on the website are for authorized Crestron dealers and Crestron Authorized Independent Programmers CAIP only New users may be required to register to obtain access to certain areas of the site including the FTP site 4 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply Physical Description This section provides information on the connections controls and indicators available
23. dress IP ID e v IPID C Remap this IP ID at program upload Default Address l e Use IP Address C Use Host Name Cancel e The ID code specified in the SIMPL Windows program must match the IP ID of each unit Refer to Identity Code on page 11 Program Manager Program Manager is the view where programmers program a Crestron control system by assigning signals to symbols The symbol can be viewed by double clicking on the icon or dragging it into Detail View Each signal in the symbol is described in the SIMPL Windows help file F1 Example Program An example program for the CEN UPS1250 is available from the Crestron website www crestron com exampleprograms Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 19 Uninterruptible Power Supply Crestron CEN UPS1250 Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features However before attempting to upload or upgrade it is necessary to establish communication Once communication has been established files for example programs or firmware can be transferred to the control system and or device Finally program checks can be performed such as changing the device ID or creating an IP table to ensure proper functioning Establishing Communication Use Crestron Toolbox
24. dvantage of the most recently released features The latest software is available from the Crestron website Crestron has developed an assortment of Windows based software tools to develop a controlled system For the minimum recommended software versions visit the Version Tracker page of the Crestron website www crestron com versiontracker Programming with Crestron SystemBuilder Crestron SystemBuilder is the easiest method of programming but does not offer as much flexibility as SIMPL Windows For additional details download SystemBuilder from the Crestron website and examine the extensive help file Programming with SIMPL Windows NOTE While SIMPL Windows can be used to program the CEN UPS1250 it is recommended to use SystemBuilder for configuring a system SIMPL Windows is Crestron s premier software for programming Crestron control systems It is organized into two separate but equally important Managers Configuration Manager Configuration Manager is the view where programmers build a Crestron control system by selecting hardware from the Device Library e To incorporate the CEN UPS1250 into the system drag the CEN UPS1250 from the Ethernet Control Modules Ethernet I O Control folder of the Device Library and drop it in the System Views Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 17 Uninterruptible Power Supply Crestron CEN UPS1250 Locating the CEN
25. er to all outputs in case of an overload condition press to reset 1 Binding post chassis ground lug 1 USB Type B female Used for factory configuration only Continued on following page 8 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply Connectors Controls amp Indicators Continued CONNECTORS DESCRIPTION CONTROLS amp INDICATORS 21 TELCO IN 1 4 pin RJ 11 female Dual line telephone connection E OUT 2 4 pin RJ 11 female Protected dual line telephone modem device connection 22 COMPUTER 1 USB Type B female Pin 2 Pin 1 USB computer console port cable included erat PIN DESCRIPTION H po 1 5 VDC Pin3 Pin 4 2 palak 3 Data 4 Ground 23 LAN 1 8 wire RJ 45 with two LED indicators SST VELON 10 100BaseT Ethernet port t Green LED indicates link status Yellow LED indicates Ethernet activity EO A PIN SIGNAL PIN SIGNAL PIN8 PIN 1 1 TX 5 N C 2 TX 6 RC 3 RC 7 N C 4 N C 8 N C 24 RESET BUTTON 1 Red miniature pushbutton resets communications board 25 ENV PROBE 6 pin mini DIN female Connection for external temperature RH sensor included 26 INPUT 120V 1 IEC 320 C14 chassis plug 47 63 Hz 12A Line power input mates with 10 ft 3 05 m MAIN
26. fault router of the CEN UPS1250 via the Crestron Toolbox Functions Ethernet Addressing otherwise enable DHCP e Confirm Ethernet connections between CEN UPS1250 and PC If connecting through a hub or router use CATS straight through cables with 8 pin RJ 45 connectors Alternatively use a CATS crossover cable to connect the two LAN ports directly without using a hub or router e Use the Address Book in the Crestron Toolbox to create an entry for the CEN UPS 1250 with the CEN UPS1250 s TCP IP communication parameters e Display the System Info window click the pi icon and select the CEN UPS1250 entry Programs and Firmware Program or firmware files may be distributed from programmers to installers or from Crestron to dealers Firmware upgrades are available from the Crestron website as new features are developed after product releases One has the option to upload programs via the programming software or to upload and upgrade via the Crestron Toolbox For details on uploading and upgrading refer to the SIMPL Windows help file or the Crestron Toolbox help file SIMPL Windows If a SIMPL Windows program is provided it can be uploaded to the control system using SIMPL Windows or Crestron Toolbox Firmware Check the Crestron website to find the latest firmware New users may be required to register to obtain access to certain areas of the site including the FTP site Upgrade CEN UPS1250 firmware via Crestron Toolbox e
27. for communicating with the CEN UPS1250 refer to the Crestron Toolbox help file for details There are two methods of communication BEES NOTE Required for initial setup of Ethernet parameters USB Communication PC RUNNING CRESTRON TOOLBOX USB CEN UPS1250 e The COMPUTER port on the CEN UPS1250 connects to the USB port on the PC via the included Type A to Type B USB cable e Use the Address Book in Crestron Toolbox to create an entry using the expected communication protocol USB When multiple USB devices are connected identify the CEN UPS1250 by entering CEN UPS1250 in the Model textbox the unit s serial number in the Serial textbox or the unit s hostname in the Hostname textbox The hostname can be found in the System Info window in the section marked Ethernet however communications must be established in order to see this information in the System Info window e Display the CEN UPS1250 s System Info window click the D icon communications are confirmed when the device information is displayed Do NOTE Required for operation with a Crestron control system Ethernet Communication PC RUNNING ETHERNET CEN UPS1250 CRESTRON TOOLBOX e Establish serial communication between CEN UPS1250 and PC 20 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply e Enter the IP address IP mask and de
28. ible beep to sound DISPLAY BEEP TEST Screen DISPLAY BEEP TEST NO PRESS NW TO CHANGE Display Beep Testing Screen SCREEN SAVER setting This function allows you to force the unit to continuously alternate the message CEN UPS POWER CONDITIONER WITH BATTERY BACKUP between the two lines of fields on the display This feature helps maintain display quality as well as extending the life of the display NOTE Even when the screen saver is set to ON the screen saver message will only display when the system load is less than 5 SCREEN SAVER Screen SCREEN SAVER ON PRESS N TO CHANGE RESET TO DEFAULT setting This function allows you to force the unit to reset all previous settings to the factory default values Simply press either the up or down arrow button The system will display two messages INITIALIZING SETUP TO FACTORY DEFAULT and INITIALIZATION COMPLETE The system then returns to the RESET TO DEFAULT screen NOTE The screen illustrations in this section show default values RESET TO DEFAULT Screen RESET TO DEFAULT NO PRESS TW TO CHANGE 30 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply Problem Solving Troublesho
29. installation procedures Furthermore this warranty does not cover any product that has had the serial number altered defaced or removed This warranty shall be the sole and exclusive remedy to the original purchaser In no event shall CRESTRON be liable for incidental or consequential damages of any kind property or economic damages inclusive arising from the sale or use of this equipment CRESTRON is not liable for any claim made by a third party or made by the purchaser for a third party CRESTRON shall at its option repair or replace any product found defective without charge for parts or labor Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty Except as expressly set forth in this warranty CRESTRON makes no other warranties expressed or implied nor authorizes any other party to offer any warranty including any implied warranties of merchantability or fitness for a particular purpose Any implied warranties that may be imposed by law are limited to the terms of this limited warranty This warranty statement supersedes all previous warranties Trademark Information All brand names product names and trademarks are the sole property of their respective owners Windows is a registered trademark of Microsoft Corporation Windows 95 98 Me XP Vista and WindowsNT 2000 are trademarks of Microsoft Corporation Operations amp Installation Guide DOC 6635A Un
30. interruptible Power Supply CEN UPS1250 e 33 CRESTRON Crestron Electronics Inc Operations amp Installation Guide DOC 6635A 15 Volvo Drive Rockleigh NJ 07647 2019504 Tel 888 CRESTRON 01 08 Fax 201 767 7576 Specifications subject to www crestron com change without notice
31. it in place Refer to illustration on page 15 2 Disconnect the battery wire connector 3 Pull the battery straight back 4 Press in the retaining tabs to allow the battery to come out completely Place the unit on a flat solid surface that is capable of supporting at least 62 pounds 28 12 kg NOTE Avoid placing other components directly on top of or behind the unit Leave at least one inch of space on all sides to allow for proper air ventilation Do not block the fan If the CEN UPS1250 unit is to be rack mounted please follow these four basic steps WARNING To prevent bodily injury when mounting or servicing this unit in a rack take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety e When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack e Ifthe rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack NOTE The rack mounting hardware that is shipped with the unit is designed for 19 inch wide racks only 12 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply NOTE Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other
32. llation Guide DOC 6635A Safety Information e i Uninterruptible Power Supply Crestron CEN UPS1250 Other Grounding This device provides a grounding lug on the rear panel for grounding the device to an external transient voltage surge suppression TVSS device Ensure these ground connections are made in accordance with the instructions provided with the TVSS device Lightning This device employs metal oxide varisters MOVs and other circuitry to protect against lightning and other sources of sudden voltage surges and sags It is not necessary to turn this device or the devices connected to this device off during a lightning storm Power Lines Do not locate outside antenna systems near overhead power lines or other electric light or power circuits or where they may fall on or otherwise come in contact with these power sources If you allow the ladder being used or the antenna itself to come into contact with these power sources it could be fatal Overloading Do not overload the wall outlet where this device is connected and do not overload this device Ensure the total load to this device does not exceed the value listed in the Specifications section of this manual Openings Do not insert any object through the device s cooling vents It may come in contact with high voltage components and cause injury death or damage to the device Do not allow liquids to enter any opening in this device Servicing This device does not cont
33. lly benefit from all available features Future Updates As Crestron improves functions adds new features and extends the capabilities of the CEN UPS1250 additional information may be made available as manual updates These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision Check the Crestron website periodically for manual update availability and its relevance Updates are identified as an Addendum in the Download column 32 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply Return and Warranty Policies Merchandise Returns Repair Service 1 No merchandise may be returned for credit exchange or service without prior authorization from CRESTRON To obtain warranty service for CRESTRON products contact an authorized CRESTRON dealer Only authorized CRESTRON dealers may contact the factory and request an RMA Return Merchandise Authorization number Enclose a note specifying the nature of the problem name and phone number of contact person RMA number and return address 2 Products may be returned for credit exchange or service with a CRESTRON Return Merchandise Authorization RMA number Authorized returns must be shipped freight prepaid to CRESTRON 6 Volvo Drive Rockleigh N J or its authorized subsidiaries with RMA number clearly marked o
34. n the outside of all cartons Shipments arriving freight collect or without an RMA number shall be subject to refusal CRESTRON reserves the right in its sole and absolute discretion to charge a 15 restocking fee plus shipping costs on any products returned with an RMA 3 Return freight charges following repair of items under warranty shall be paid by CRESTRON shipping by standard ground carrier In the event repairs are found to be non warranty return freight costs shall be paid by the purchaser CRESTRON Limited Warranty CRESTRON ELECTRONICS Inc warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three 3 years from the date of purchase from CRESTRON with the following exceptions disk drives and any other moving or rotating mechanical parts pan tilt heads and power supplies are covered for a period of one 1 year touchscreen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse accidental damage modification or improper
35. nit provides power to the rear panel outlets marked BANK 3 and BANK 4 respectively By setting this delay it prevents power on or power off glitches from affecting other equipment connected to the unit OUTLET DELAYI1 Screen OUTLET DELAY 1 5SEC PRESS TW TO CHANGE 28 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply OUTLET DELAY2 Screen OUTLET DELAY2 5SEC PRESS TW TO CHANGE LOWBATWARNING setting This screen lets you set the unit to sound an alarm and illuminate the LOW BATT LED on the front panel whenever the battery pack s estimated runtime remaining drops to or below the programmed setting 2 to 26 minutes LOWBATWARNING Screen LOWBATWARNING 2MIN PRESS N TO CHANGE BATREPDATE setting This function allows you to input the exact date a replacement battery pack is installed in the unit First use the up down arrow buttons to set the correct month then press the SETUP button to move the cursor to the day of the month field Set the day of the month using the up down arrow buttons Press the SETUP button to move the cursor to the year field Set the year using the up down arrow buttons BATREPDATE Screen BATREPDATE 02 19 07 PRESS N TO CHANGE DO QUICK SELFTEST setting This function lets you manually initiate a selftest to ensure the battery pack i
36. oting The following table provides corrective action for possible trouble situations If further assistance is required please contact a Crestron customer service representative CEN UPS1250 Troubleshooting TROUBLE POSSIBLE CORRECTIVE ACTION CAUSE S Device does Battery is not Remove the front bezel by grasping the not function connected handles and pulling straight back The battery is located on the right side of the unit The black battery connector should be pushed snugly into the battery socket located just to the left of the battery pack Refer to Inserting and Connecting the Battery in the Installation section which starts on page 11 No power or Ensure the wall outlet has good power insufficient power by checking it with a voltmeter or by is available at the plugging the power cord of a known wall outlet good device into the outlet NOTE The unit will not turn on and accept incoming utility power if the power is out of range The unit can still be cold started using battery power by pressing and holding the power switch in until the unit beeps Circuit breaker Check both your home and unit circuit has tripped breakers If the circuit breaker on the rear of the CEN UPC1250 has tripped the center post will be extended out about to inch Push it back in to reset it If it trips again reduce the number of devices that are plugged into the unit one at a time and try again
37. page it will make lifting and positioning the unit much easier Lift the unit carefully Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 11 Uninterruptible Power Supply Crestron CEN UPS1250 Ventilation Removing the Battery Pack Installing on a Flat Surface Rack Mounting by firmly grasping both sides of the unit in the middle Failure to comply may result in personal injury and or damage to the equipment WARNING The CEN UPS1250 should not be lifted or moved using the two handles on the front panel These are intended only for removing the front panel to access the internal battery not for lifting or positioning the unit The CEN UPS1250 should be used in a well ventilated area The venting holes should not be obstructed under any circumstances To prevent overheating do not operate this product in an area that exceeds the environmental temperature range listed in the table of specifications Consider using forced air ventilation and or incrementing the spacing between units to reduce overheating Consideration must be given if installed in a closed or multi unit rack assembly since the operating ambient temperature of the rack environment may be greater than the room ambient temperature Contact with thermal insulating materials should be avoided on all sides of the unit To remove the battery pack 1 Remove the battery retaining bar after loosening the thumb screw that holds
38. phs describe the various status and informational screens that are available with the CDN UPS1250 These are accessed by using the STATUS button on the front panel NOTE For your convenience you can set the unit to display any of the status screens as the default screen The default screen is the screen that the system will return to once the preset time has expired for other screens that are being displayed NOTE The display will revert to the default screen after about 30 seconds of inactivity To change the default screen first press the STATUS button until the desired screen is displayed Then press and hold the STATUS button for approximately three seconds until the screen displays CURRENT SCREEN IS SAVED AS DEFAULT The SOURCE XXXXXXX EST RUNTIME XHRS screen displays which type of source the unit is deriving power from UTILITY BATTERY or STANDBY It also displays the EST RUNTIME based on the power source and connected equipment load In STANDBY the unit does not provide power to the rear panel outlets NOTE When the CEN UPS1250 is connected to utility power the electronics inside the unit are active If the front panel power switch is turned off the unit goes into STANDBY mode and shuts off power to the rear panel outlets but the display remains active SOURCE UITLITY EST RUNTIME XHRS Screen SOURCE UTILITY EST RUNTIME 2HRS SOURCE BATTERY EST RUNTIME XHRS Screen
39. press of a single button or control system command Up to 10 seconds of delay adjustment on banks 3 and 4 enables customized sequential switching capability Sequential switching ensures that all the components of a complete system are powered up and down in proper order avoiding dangerous transients that can damage delicate components and trip the main circuit breaker Components such as video projectors and media servers that require systematic shutdown and restart can be managed seamlessly through integration with a control system Automatic Voltage Regulation Keeping the voltage within a safe operating range helps prevent equipment malfunctions and can even improve audio and video performance Using automatic voltage regulation the CEN UPS1250 can correct for many high and low voltage fluctuations without having to switch to battery operation preserving battery fuel for more serious situations Surge Protection The CEN UPS1250 provides thorough protection against surges spikes and lightning In addition to power line protection on all 12 outlets there is also built in surge protection for two separate coax lines and one telephone line delivering a complete solution for protecting TVs cable and satellite receivers modems and conferencing devices Noise Filtering Built in EMI and RFI noise filtering eliminates the electromagnetic and radio frequency interference that can negatively impact sound and video quality Each of the four o
40. r the unit detects an internal problem or a problem with an externally connected battery pack When it is set to OFF the audible tone is silenced AUDIBLE ALARM Screen AUDIBLE ALARM OFF PRESS TW TO CHANGE SENSITIVITY setting This feature is used to adjust how the unit reacts to input voltage waveform distortion and momentary power fluctuations It allows you to adjust the sensitivity of the CEN UPS1250 to LOW MEDIUM and HIGH using the up down arrow buttons The SENSITIVITY adjustments have the following values e HIGH This should be used when the connected equipment is sensitive to momentary low voltage or brief power fluctuations When it is set to HIGH the unit is very sensitive to voltage distortion and is more likely to switch back and forth to battery power than it would at a MEDIUM or LOW setting e MEDIUM This is the default setting suitable for most situations e LOW this setting should be used when the CEN UPS1250 frequently goes to battery even though the utility voltage appears normal SENSITIVITY Screen SENSITIVITY MEDIUM PRESS TW TO CHANGE DISPLAY DIMMER setting This lets you set a brightness level for the display of HIGH LOW or OFF Repeatedly pressing the up down arrow buttons allows you to set the brightness of the display Once the display brightness is set to the desired level press the SETUP button to store the setting NOTE Even when the display
41. s in good health and that the unit is operating properly NOTE When you advance to this screen press the up down arrow buttons to start the selftest During the selftest the same screens that were previously defined in this manual are displayed Refer to Performing the System Test on page 22 for details DO QUICK SELFTEST Screen DO QUICK SELFTEST NO PRESS NW TO CHANGE DO RUNTIME CAL setting This function allows you to manually initiate a runtime calculation test to calibrate internal measurements which should result in more accurate runtime estimates This should be done once every six months or when the connected load size changes significantly Once initiated the unit will operate on battery power until a low battery condition occurs NOTE Before you initiate RUNTIME CAL the battery must be at 100 capacity fully charged and the load must be greater than 10 of the rated load Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 29 Uninterruptible Power Supply Crestron CEN UPS1250 DO RUNTIME CAL Screen DO RUNTIME CAL NO PRESS NW TO CHANGE DISPLAY BEEP TEST setting This function allows you to force the unit to perform display and beep tests Simply press either the up or down arrow button This will cause all the indicators and display fields to illuminate as shown in the illustration on the following page and an aud
42. s tracks but it can also cause the loss of precious data and system settings and can even damage hard drives and other vulnerable components The CEN UPS1250 constantly monitors the incoming power line and instantly transfers power to battery backup in the event of such a power loss ensuring the connected components continue to operate unhampered It may also be configured to transfer to battery in the case of an over or under voltage condition or Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 1 Uninterruptible Power Supply Crestron CEN UPS1250 if excessive line noise or distortion is detected ensuring optimum performance of sensitive video and audio equipment during momentary power glitches When running on battery backup the CEN UPS1250 can power a rack full of equipment for several minutes without interruption In the event of a prolonged power outage a properly managed shutdown of the equipment can be performed automatically Configurable load shedding allows only certain components to be shut down preserving battery fuel and extending runtime for more vital components The CEN UPS1250 will also ensure a smooth changeover from primary power to a backup generator Managed Power Control The CEN UPS1250 provides twelve 120 Volt power outlets organized in four banks Each of the four banks of outlets is independently switchable with fully managed power up and shutdown available at the
43. signed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures z Reorient or relocate the receiving antenna z Increase the separation between the equipment and receiver n Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 7 Consult the dealer or an experienced radio TV technician for help 10 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply Setup Ethernet Unlike other Crestron network devices the CEN UPS1250 does not use Cresnet for communications between the device and the control system The CEN UPS1250 requires the use of a high speed Ethernet connection for control system communications For information on connecting Ethernet devices in a Crestron system refer to the latest version of the Crestron e Control Reference
44. than direct connections to the branch circuit e g use of power strips 1 Install the rack mount rails refer to illustration below 2 Install the rail cleats refer to illustrations on the following page 3 Install the rack mount ears optional CAUTION Rack mount ears should not be used alone to support the unit Rack mount rails should always be used to support the unit s weight when it is mounted in a rack NOTE Rack mount ears are required only if you want to lock the unit to the front of the rack to prevent front to rear movement 4 Slide the unit into the rack so that the cleats mounted on the side of the unit fit within the track of the rack mount rails If the ears were mounted screw the mounted ears into the rack to lock the unit into position NOTE Avoid placing other components directly on top of or behind the unit Leave at least one inch of space on all sides to allow for proper air ventilation Do not block the vents or fan Installing Rack Mounting Rails Screws 10 10 32 x 72 ae Pa 2020255 a a of a Left Rail Assembly 2020250 y Right Rail Assembly 2020251 Screws 10 10 32 x gt 2020255 Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 13 Uninterruptible Power Supply Crestron CEN UPS1250 Attaching Cleats and Rack Mount Ears Cleats 2 2 Formed 2020257
45. tralized monitoring and logging via RoomView provides an invaluable resource for quickly resolving power line problems and maintaining batteries Built in Logging In addition to RoomView the CEN UPS1250 also supports onboard timestamp logging Data can be set to log every 1 to 60 minutes with sufficient memory for at least 30 days of history recording the load battery condition line voltage outlet on off status and environmental conditions Instantaneous events such as switching to battery low battery warnings and self tests are also logged Rack Mountable A heavy duty rack mount hardware kit is provided to mount the unit into any EIA standard four post 19 equipment rack up to 28 deep The feet on the bottom of the unit can be unscrewed and removed to save space when the unit is rack mounted Specifications Specifications for the CEN UPS1250 are listed in the following table CEN UPS1250 Specifications SPECIFICATION DETAILS UPS Power Conditioner Output Power Capacity 1250 Watts 1440 VA 120 Volts AC nominal Efficiency 90 at full load Output Voltage Distortion lt 5 at full load Output Frequency 47 to 63 Hz sync to line power input Waveform Type Sine wave Transfer Time 7 ms typical 10 ms maximum during blackout Power Line Surge Protection Rated for 4080 Joules Filtering Full time multi pole noise filtering 5 IEEE surge let thru zero clamping response time meets UL 1449 Dataline protection
46. uences through display of various electrical and environmental measurements operational status battery condition and other system information 4 DISPLAY Vacuum fluorescent 2 lines x 20 characters per line 5 A V BUTTONS 2 Used to adjust configuration settings up down or on off 6 LOW BATT LED 1 red Indicates remaining backup time has fallen below a preset amount adjustable from 2 to 26 minutes 7 AC PWR OK LED 1 green Indicates the line input voltage is within the acceptable operating range of 92 V to 142 V 8 DELAY AMP LED 1 green Indicates the BANK 4 HI CURRENT DEVICES output bank is turned on 9 REGULATING LED 1 green Indicates voltage regulation is operating to compensate for a high or low line voltage condition 10 SETUP BUTTON 1 Sequences through various configuration settings and operations 11 POWER STANDBY 1 Turns all output banks on or off forces BUTTON cold start to battery when held 12 OVERLOAD LED 1 red Indicates there is too much load connected to the output Continued on following page Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 7 Uninterruptible Power Supply Crestron CEN UPS1250 Connectors Controls amp Indicators Continued CONNECTORS CONTROLS amp INDICATORS DESCRIPTION 13 14 15 16 17 18 19 20 FILTERING LED OUTLET BANKS EXTERNAL BATTERY CABLE nC Chur
47. uits when updating the status screen This condition is considered part of the normal operation of the unit INPUT VOLTAGE XXXV OUTPUT VOLTAGE XXXV Screen INPUT VOLTAGE 124V OUTPUT VOLTAGE 125V The INPUT FREQ XXHZ OUTPUT FREQ XXHZ screen displays the actual input utility voltage frequency as well as the actual voltage frequency being output to the connected devices NOTE At times the frequency values on this screen may not match This is because separate circuits are used to make frequency measurements and there is a time delay between the two circuits when updating the status screen This condition is considered part of the normal operation of the unit INPUT FREQ XXHZ OUTPUT FREQ XXHZ Screen INPUT FREQ 60HZ OUTPUT FREQ 60HZ The outlet status screens shown below display which of the four outlet banks are turned on or off The outlet banks can be turned on or off independently using a control system connected via the LAN port on the rear panel BANKI DIGITAL ON BANK2 DISPLAY ON Screen BANK1 DIGITAL ON BANK2 DISPLAY ON Operations amp Installation Guide DOC 6635A Uninterruptible Power Supply CEN UPS1250 e 25 Uninterruptible Power Supply Crestron CEN UPS1250 BANK3 ANALOG ON BANK4 HI AMP ON Screen BANK3 ANALOG ON BANK4 HI AMP ON The model number and serial number screen displays information about your
48. utlet banks provides filtering protection specialized for a specific type of device DIGITAL DISPLAY ANALOG and HI CURRENT Each bank is electrically isolated to prevent any noise present on one bank from reaching the devices connected to any other bank Environmental Monitoring Using the included external probe ambient temperature and relative humidity levels can be measured recorded and even reported to the control system or central help desk Using this feature safe operating limits can be specified for all of the equipment within a room or rack so that whenever the limits are exceeded the user is notified climate control is adjusted and if necessary the equipment can be powered down safely 2 e Uninterruptible Power Supply CEN UPS1250 Operations amp Installation Guide DOC 6635A Crestron CEN UPS1250 Uninterruptible Power Supply RoomView and Control System Integration Monitoring and operation of the CEN UPS1250 extends beyond its front panel providing direct communication with Crestron s RoomView Remote Asset Management Software as well as with Ethernet enabled 2 Series control systems The CEN UPS1250 notifies RoomView whenever it switches to battery backup and warns if the battery is low or overloaded It also reports which outlet banks are on as well as the line voltage output voltage frequency voltage regulation status system load internal temperature ambient temperature and humidity and battery condition Cen