Home
Campbell Hausfeld WT4500 eBook Reader User Manual
Contents
1. 11 www chpower com Propane Torch Kit Juego de soplete de propano Notes Notas www chpower com 10 Models WT4500 and WT5500 Figure 3 Hand tightening cylinder connection 4 gt gt i Figure 4 Tightening cylinder connection with wrench Figure 5 Turning gas valve clockwise to close counterclockwise to open WT4500 shown WT5500 similar Lighting Instructions Cont DO NOT smoke supply tank to open flames or sparks DO NOT apply heat AWARNING or flame to tank to check for leaks Excess heat may cause the tank to rupture possibly causing personal injury 3 Slowly open valve on torch about 1 8 turn until you hear gas flow AWARNING around or expose 4 For the WT4500 use flint striker to ignite torch by creating a spark near torch nozzle see Figure 6a For the WT5500 press the piezo ignitor switch near handle see Figure 6b Do not use matches AAWARNING or cigarette lighter to ignite torch 5 Adjust flame to a minimal level with torch gas valve Torch Use Point torch at what you want to heat and pull Turbo Blast Trigger to intensify the size of the flame see Figure 7 Release trigger to bring flame back to minimal level NOTE If you have the torch gas valve open too high when you pull the
2. almacenamiento y manipulaci n de gases de petr leo licuados Ensamblaje L NEA DE GAS AL SOPLETE Con las llaves que se proporcionan ensamble la l nea de gas al mango del soplete Use una llave para sostener la conexi n del soplete de modo que no gire en el mango del soplete Use la otra llave para ajustar la conexi n de la manguera de gas en la conexi n del mango La conexi n del gas usa una rosca a la izquierda Gire hacia la izquierda para apretar Vea la figura 2 Figura 2 Conexi n de la l nea de gas al mango WT4500 se muestra WT5500 similar L NEA DE GAS AL CILINDRO Figura 4 Ajuste de la conexi n del cilindro usando una llave By AL de Figura 5 Giro de la v lvula de gas a la derecha para cerrar a la izquierda para abrir WT4500 se muestra WT5500 similar Instrucciones de encendido 1 Aseg rese de que la v lvula de gas en el soplete est bien cerrada apriete bien hacia la derecha Figura 6b Uso de un encendedor piezom trico AADVERTENCIA NO Io ponga en funcionamiento si existe alguna p rdida Una p rdida puede crear un peligro de incendio AADVERTENCIA NO fume en las proximidades ni exponga el tanque de suministro a llamas o chispas APRECAUCION NO aplique calor ni llamas al tanque para verificar la existencia de p rdidas El exceso de calor puede causar la ruptura del tanque causando posiblemente
3. propane torch Keep children and pets away from this product when in use Do not leave the torch unattended while in operation e Do not stand or prop the torch on the burner end while in operation Do not try to enlarge or make any modifications to the nozzle outlet The nozzle and orifice are precisely matched Any modification can create the possibility of liquid propane release e This product is designed to be operated on vapor withdrawal LP liquid propane gas only Use of any other gas may result in device failure or personal injury e This product should be used with 20 propane cylinders with standard POL valve fittings It should meet or exceed NFPA 58 Standard for the storage and handling of liquefied petroleum gasses Before each use always check fittings and connections to make sure there are no leaks e When not in use the gas should be turned off at the LP gas tank e The LP tank must be on a level surface in an upright position Do not invert or lay tank on its side e Have an ABC type fire extinguisher readily accessible at the work site Before each use check the gas hose for wear cuts or leaks If the hose is more than 5 years old as marked on the hose replace it Do not attempt to repair Contact Campbell Hausfeld for replacement under warranty Never store a torch AWARNING that is stili hot Be aware that the AACAUTION nozzle of the torch becomes very hot
4. Turbo Blast Trigger the flame will tend to blow out and require reignition On the WT5500 there is an adjustable brass knob used to limit the distance the Turbo Blast Trigger can move Turn the valve clockwise for a smaller flame Turn it counterclockwise for a larger flame As a safety precaution these units Figure 7 Pi g trigger for flame turbo blast WT4500 shown WT5500 similar are equipped with an excess flow check valve that shuts off the gas in the event of a damaged or severed hose If you allow the flame to grow too large the excess flow check valve will automatically shut off gas flow to the torch To extinguish the flame close the torch gas flow valve and propane cylinder valve Make certain that torch is completely cooled before storing The torch nozzle will be very hot Do not touch it or rest it on anything that can be damaged by heat Maintenance Prior to each use 1 Inspect all components of the device for damage and or wear If the hose shows AWARNING excessive abrasion or wear if the hose is cut or if it is more than 5 years old it must be replaced prior to operation 2 Inspect LP gas tank for dents damage to collar damage to shut off valve or corroded foot ring If dents damage to AWARNING collar damage to shut off valve or corroded foot ring are present the LP gas tank must be replaced prior to operation 3 Perform a leak test using soapy
5. compren pra RIA la muerte o heridas de AVISO indica da las siguientes gu as antes de usar el pelke una informaci n importante que de no soplete Esto le seguirla le podr a ocasionar da os al AADVERTENCIA Figa que guita le pod hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad e Este producto est dise ado para usar nicamente en exteriores RECORDATORIO Guarde su comprobante de compra con fecha para fines de la garant a Adj ntela a este manual o arch vela en lugar seguro O 2005 Campbell Hausfeld Scott Fetzer IN972001AV 1 05 Juego de soplete de propano Informaci n de s eguridad Cont Este producto produce una llama que puede hacer que otros materiales combustibles e inflamables se quemen Por ejemplo si usa la llama para ablandar pintura en madera puede da ar o incluso encender la madera No use el soplete cerca de ning n l quido gas o OFM e Nunca deje que los ni os usen el soplete de propano Mantenga a los ni os y a las mascotas alejados de este producto cuando lo est usando No desatienda el soplete mientras est funcionando No coloque ni apoye el soplete sobre el extremo del quemador mientras est en funcionamiento No intente alargar o realizar ninguna modificaci n a la salida de la boquilla La boquilla y el orificio coinciden en forma precisa Cualquier modificaci n AVISO fea leva
6. lesiones personales 3 Abra lentamente la v lvula del soplete aproximadamente 1 8 de vuelta hasta que escuche el flujo de gas 4 Para el WT4500 use un yesquero 4 ADVERTENCIA No use cerillas ni encendedores de cigarrillos para encender el soplete 5 Ajuste la llama a un nivel m nimo con la v lvula de gas del soplete Uso del soplete Apunte el soplete en direcci n a lo que desea calentar y tire del Gatillo de inyecci n turbo para intensificar el tama o de la llama vea la figura 7 Suelte el gatillo para llevar la llama nuevamente al nivel m nimo NOTA Si tiene la v lvula de gas del soplete demasiado abierta cuando tire del Gatillo de inyecci n turbo la llama tender a apagarse y ser necesario volver a encenderla El WT5500 tiene una perilla de bronce ajustable que se usa para limitar la distancia que se puede mover el Gatillo de inyecci n turbo Gire la v lvula hacia la derecha para una llama m s peque a G rela hacia la izquierda para una llama m s grande Como precauci n de seguridad estas unidades est n equipadas con una v lvula de retenci n de flujo que cierra el gas en el caso de una manguera da ada o cortada Si deja que la llama sea demasiado grande la v lvula de retenci n de flujo excesivo apagar autom ticamente el material de este tipo e Nunca apunte el soplete en direcci n a ninguna persona o animal para encender el soplete creando una chispa cerca de
7. when in use Do not lift the NOTICE propane tank by the valve SAFETY PUBLICATIONS RELATED TO SAFE PRACTICE AND USE IAS 2 94 US Requirements for Hand Held LP Torches for use with fuel supply ANSI Z49 1 Safety in welding and cutting NFPA 54 National Fuel Gas Code NFPA 58 Standard for the storage and handling of liquefied petroleum gases Assembly GAS LINE TO TORCH With the wrenches provided assemble gas line to torch handle Use one wrench to hold torch fitting so it does not turn in the torch handle Use the other wrench to tighten gas hose fitting onto handle fitting The gas fitting uses a left handed thread Turn counterclockwise to tighten See Figure 2 Figure 2 Attaching gas line to handle WT4500 shown WT5500 similar GAS LINE TO CYLINDER Insert hose fitting into gas cylinder valve and turn counterclockwise to tighten Use an adjustable wrench to tighten the fitting See Figures 3 and 4 Lighting Instructions 1 Be sure gas valve on torch is closed tightly turn tight clockwise see Figure 5 2 Open valve on propane cylinder and check all components for leaks use soapy water or leak test solution DO NOT operate if AAWARNING any leaks are present A leak may create a fire hazard www chpower com Models WT4500 and WT5500 Modelos WT4500 y WT5500 Notes Notas
8. EL SOPLETE ES APENAS VISIBLE NO ponga la mano ni ninguna otra parte del cuerpo en la ruta de la llama mientras est encendiendo o usando el soplete Antes de usar determine si alguno de los materiales que se calentar con el soplete puede encenderse explotar o producir gases t xicos NO deje que la llama ni el calor entren en contacto con ning n usado solamente con extracci n de gas LP propano l quido El uso con cualquier otro gas puede provocar fallos o lesiones personales e Este producto se debe usar con cilindros de gas propano N 20 con conexiones de v lvula POL est ndar Debe cumplir o exceder el NFPA 58 Est ndar para el almacenamiento y manipulaci n de gases de petr leo licuados e Antes de cada uso revise siempre los accesorios y conexiones para asegurarse de que no haya p rdidas e Cuando no lo est usando se debe cerrar la salida de gas en el tanque de gas LP El tanque LP debe estar sobre una superficie nivelada en posici n vertical No invierta ni apoye el tanque sobre su lado Tenga un extintor de incendios tipo ABC disponible de inmediato en el lugar de trabajo e Antes de cada uso revise la manguera de gas para detectar desgastes cortes o p rdidas Si la manguera tiene m s de 5 a os como se marca en la manguera reempl cela No intente repararla P ngase en contacto con Campbell Hausfeld para el reemplazo bajo la garant a AADVERTENCIA ure
9. EQUIPMENT PROBLEMS To help recognize this information observe the following symbols Danger indicates AADANGER an aminen ely hazardous situation which if not avoided WILL result in death or serious injury Warning indicates LAWARNING a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a ACAUTION potentially hazardous situation which if not Torch Handle Fitting Torch Handle Handle Fitting Gas Control Valve Nozzle Turbo Trigger Gas Hose POL Tank Fitting Figure 1a WT4500 Torch and Components POL Tank Fitting Torch Handle Fitting Nozzle Gas Control Valve Torch Handle ge Handle Fitting Piezo Ignitor Turbo Trigger Gas Hose a Turbo Trigger Limit Adjustment Figure 1b WT5500 Torch and Components avoided MAY result in minor oi H moderate injury A r Safety Information Notice indicates Read and NOTICE important AWARNING understand the information that if not followed may following guidelines before using the cause damage to equipment torch REMINDER Keep your dated proof of purchase for warranty purposes Attach it to this manual or file it for safekeeping 2005 Campbell Hausfeld Scott Fetzer For parts manuals product amp service information IN972001AV 1 05 visit www chpower com Propane Torch Kit Safety Inf
10. Propane Torch Kit Juego de soplete de propano Notes Notas Operating Instructions Models WT4500 and WT5500 Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference www chpower com 12 CAMPBELL Propane HAUSFELD Torch Kit CES BUILT TO LAST Description This Campbell Hausfeld propane torch is a versatile tool with many applications from stump burning to cattle branding With it you can e Kill unwanted weeds and grass without using expensive and toxic chemicals Melt ice from sidewalks without salt and thaw outdoor frozen pipes in the winter Use the torch to heat tar in roofing and asphalt sealing projects e Soften paint for removal without using chemicals This torch should be used with a 20 LP tank with a standard POL type valve like the type typically used with a gas grill With the trigger activated turbo burner you save fuel by emitting heat only when it is needed Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT
11. above limitations may not apply to you c Any failure that results from accident purchaser s abuse neglect or failure to operate products in accordance with instructions provided in the owner s manual supplied with the product 6 Responsi which have failed within duration of the warranty period 7 Responsibi care in the operation and maintenance of the product es of Warrantor under this warranty Repair or replace at Warrantor s option products or components ies of Purchaser under this warranty Deliver or ship the product to Campbell Hausfeld Use reasonable 8 When Warrantor will perform repair or replacement under this warranty Repair or replacement will be scheduled and serviced according to the normal workflow at the servicing location This Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state www chpower com Modelos WT4500 y WT5500 Garantia Limitada por Un Afio 1 Duraci n El fabricante garantiza que reparar sin cargo por piezas o mano de obra el Soplete de Propano que se pruebe que tenga defectos de material o mano de obra durante el primer a o posterior a la fecha de compra original 2 Qui n otorga esta garant a garante Campbell Hausfeld The Scott Fetzer Company 100 Production Drive Harrison OH 45030 Tel fono 513 367 4811 3 Qui n recibe esta garant a comprador El comprador original del producto Campbell H
12. ausfeld 4 Qu cubre esta garant a Defectos en el material y la mano de obra que tengan lugar dentro del per odo de garant a de un a o Esta garant a se extiende nicamente al soplete la manguera y las conexiones 5 Qu no cubre esta garant a a Las garant as impl citas incluyendo aquellas de comercializaci n e idoneidad para un prop sito espec fico est n limitadas en duraci n a esta garant a expresa Despu s de este per odo todos los riesgos de p rdida sin importar el motivo ser n responsabilidad del comprador b Cualquier p rdida da o o gasto incidental indirecto o consecuente que pueda resultar de cualquier defecto falla o mal funcionamiento del producto Campbell Hausfeld En algunos estados no se permiten las limitaciones respecto de la duraci n de una garant a impl cita por lo cual las limitaciones antedichas pueden no ser aplicables en su caso c Cualquier fallo que sea el resultado de accidente abuso negligencia por parte del comprador o si ste no hace funcionar los productos de acuerdo con las instrucciones proporcionadas en el manual del propietario que se entrega con el producto 6 Responsabilidades del garante en virtud de esta garant a Reparaci n o reemplazo seg n la opci n del garante de productos o componentes que hayan fallado dentro de la duraci n del per odo de garant a 7 Responsabilidades del comprador en virtud de esta garant a Entregar o enviar el producto a Campbell Hausfe
13. didas 4 Encienda el soplete de acuerdo a las instrucciones de encendido Verifique el funcionamiento de la v lvula de ajuste y de todos los dem s componentes antes de continuar Peri dicamente 1 Retire cualquier residuo o material combustible del soplete El soplete se debe mantener limpio y sin materiales combustibles 2 La superficie del dispositivo se debe limpiar con agua y jab n No use limpiadores inflamables o a base de petr leo sobre ninguna parte del dispositivo C mo desconectar el AVISO tanque de sumin istro NO levante el tanque tom ndolo LP de la v lvula El levantar el tanque tom ndolo de la v lvula podr a ocasionar da os a la v lvula 1 Aseg rese de que la v lvula del tanque de suministro est cerrada 2 Abra brevemente la s v lvula s de ajuste del soplete para liberar cualquier gas residual que a n est en la manguera 3 Cierre la v lvula de ajuste 4 Desconecte la tuerca niple POL ubicada en el extremo del ensamble de la manguera desde el tanque de suministro gir ndola hacia la derecha con una llave ajustable Almacenaje Nunca guarde un soplete que est caliente Cuando el soplete se guarda en interiores la conexi n entre el tanque de gas LP y el dispositivo debe estar desconectada Adem s se debe retirar el tanque del dispositivo y se lo debe guardar en el exterior de acuerdo con el Cap tulo 5 del Est ndar para el almacenamiento y manipu
14. la boquilla del soplete vea la figura 6a Para el WT550 presione el interruptor del encendedor piezom trico cerca del mango vea la figura 6b guarde Introduzca la conexi n de la manguera un soplete que a n est caliente en la v lvula del cilindro de gas y gire APRECAUCION Tenga en hacia la izquierda para apretar Use cuenta una llave ajustable para apretar la que la boquilla del soplete se calienta conexi n Vea las figuras 3 y 4 mucho cuando est en uso vea la Figura 5 flujo de gas al soplete 2 Abra la v lvula del cilindro de propano y verifique todos los componentes para detectar p rdidas use agua con jab n o una soluci n para revisar p rdidas Para apagar la llama cierre la v lvula de flujo de gas del soplete y la v lvula del cilindro de propano Aseg rese de que el soplete 6Sp 7 Sp
15. laci n de gases de petr leo licuados ANSI NFPA 58 El tanque LP debe estar sobre una superficie nivelada en posici n vertical No invierta ni apoye el tanque sobre su lado AADVERTENCIA La temperatura de almacenamiento no debe exceder de 120 F 49 3 C AADVERTENCIA NO fume en las proximidades ni exponga el tanque de suministro a llamas o chispas AADVERTENCIA El ensamble de la manguera debe estar protegido contra el tr fico aplastamiento y superficies calientes para evitar el desgaste prematuro de la manguera 8Sp Manual de Instrucciones Modelos WT4500 y WT5500 Sirvase leer y guardar estas instrucciones Lea con cuidado antes de tratar de armar instalar manejar o darle servicio al producto descrito en este manual Prot jase Ud y a los dem s observando todas las reglas de seguridad El no seguir las instrucciones podr a resultar en heridas ylo da os a su propiedad Guarde este manual como referencia CAMPBELL AUS ELO Juego de soplete de propano BUILT TO LAST Descripci n Este soplete de propano Campbell Hausfeld es una herramienta vers til con muchas aplicaciones desde quemar V lvula de control de gas tocones hasta marcar ganado Con la AA herramienta puede e Matar hierbas y pastos no deseados sin necesidad de usar productos qu micos costosos y t xicos Boquilla Conexi n del mango del soplete Mango del soplete Conexi
16. ld Tener un cuidado razonable en el manejo y mantenimiento del producto 8 Cu ndo deber el garante llevar a cabo la reparaci n o el reemplazo en virtud de esta garant a La reparaci n o el reemplazo se establecer n y se llevar n a cabo de acuerdo al flujo de trabajo normal en la instalaci n de servicio Esta garant a limitada le proporciona derechos legales espec ficos y tambi n puede tener otros derechos que var an de un estado a otro 9 Sp Juego de soplete de propano Uso del soplete cont est totalmente fr o antes de guardarlo La boquilla del soplete estar muy caliente No la toque ni la apoye sobre cualquier cosa que se pueda da ar por el calor Mantenimiento Antes de cada uso 1 Inspeccione todos los componentes del dispositivo para detectar da os y o desgaste AADVERTENCIA Si la manguera muestra abrasion o desgaste excesivos si esta cortada o si tiene m s de 5 a os se la debe reemplazar antes de poner en funcionamiento 2 Inspeccione el tanque de gas LP para detectar abolladuras dafios en el cuello da os en la v lvula de cierre o corrosi n en el aro de apoyo 4 ADVERTENCIA Si tiene abolladuras da os en el cuello da os en la v lvula de cierre o corrosi n en el aro de apoyo el tanque de gas LP se debe reemplazar antes de poner en funcionamiento 3 Realice una prueba de p rdidas usando agua con jab n o una soluci n para revisar p r
17. n del mango e Derretir hielo de aceras sin usar sal Gatillo turbo y descongelar tuber as congeladas de exterior en el invierno M ad e Usar el soplete para calentar brea en anguste ds gas trabajos de techos y de sellado con asfalto Figura 1a Soplete y componentes WT4500 Conexi n del tanque POL e Ablandar pintura para su remoci n sin usar productos qu micos m Conexi n del tanque POL Conexi n del Este soplete se puede usar con un tanque N 20 LP con una v lvula Boquilla est ndar tipo POL como la del tipo que se usa generalmente con una parrilla a gas Con el quemador turbo de activaci n con gatillo usted ahorra combustible al emitir calor s lo cuando lo necesita mango del soplete V lvula de control de gas jango del soplete D Conexi n del mango Encendedor H i tri Gatillo Gu as de seguridad piezom trico cate Manguera de gas Este manual contiene informaci n que Ajuste de limite es muy importante que sepa y del gatillo turbo comprenda Esta informaci n se la suministramos como medida de Figura 1b Soplete y componentes WT5500 SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los Esto le siguientes s mbolos APRECAUCION a Informaci n de APELIGR Esto lo hay una situaci n que PODRIA ocasionarle SC uridad indica que heridas no muy graves A PRE CAUCI ON Lea y hay una situaci n inmediata que LE Esto le
18. nte el tanque de propano tom ndolo por la v lvula PUBLICACIONES DE SEGURIDAD RELACIONADAS A LAS PR CTICAS Y EL USO SEGUROS IAS 2 94 Requerimientos de los EE UU para sopletes LP manuales para usar con fuentes de combustible ANSI Z49 1 Seguridad para soldaduras y cortes Modelos WT4500 y WT5500 Figura 3 Ajuste manual de la conexi n del cilindro Figura 7 Accionamiento del gatillo para inyecci n turbo de la llama material inflamable puede crear la posibilidad de fugas NFPA 54 C digo Nacional para WT4500 se muestra WT5500 similar NUNCA dirija la llama del depropanio liquid gases combustibles soplete hacia la manguera o el e Este producto est dise ado para ser NFPA 58 Est ndar para el tanque de gas NO aplique calor o llamas al tanque para verificar la presencia de p rdidas o aumentar la presi n de gas Siempre use gafas de seguridad aprobadas por ANSI cuando arme y use este yy producto Se recomienda usar mangas largas guantes y botas Si est usando este producto y detecta olor a gas apague inmediatamente la v lvula del tanque Extinga cualquier llama Use agua con jab n para revisar el dispositivo en busca de p rdidas NO intente volver a encender el dispositivo hasta que se hayan reparado todas las p rdidas y ya no haya olor a gas No haga funcionar este producto si est bajo la influencia de drogas o alcohol A LA LUZ DEL D A LA LLAMA D
19. ormation Cont e This product is intended for outdoor use only e This product produces a flame that can cause OTK other combustible and Y flammable materials to burn For example if using the flame to soften paint on wood you can damage or even ignite the wood Do not use the torch around any flammable fluids M A gasses or materials Hy NEVER direct the torch flame toward the hose or gas tank DO NOT apply heat or flame to the tank to check for leaks or increase gas pressure e Always wear ANSI approved safety goggles when assembling and using this v product Long sleeves gloves and boots are recommended e If you are using this product and notice a gas odor immediately shut off the tank valve Extinguish any open flame Check the device for leaks using soapy water DO NOT attempt to reignite the device until all leaks are repaired and there is no gas smell Do not operate this product if under the influence of alcohol or drugs e IN DAYLIGHT THE TORCH FLAME IS BARELY VISIBLE DO NOT place hand or any other body part in the path of the flame while lighting or operating the torch Before use determine whether any materials that will be heated by the torch will ignite explode or produce toxic fumes DO NOT allow flame or heat to come into contact with any such materials e Never point the torch toward any person or animal Never allow children to use the
20. ose assembly AWARNING must be protected from traffic crushing and hot surfaces to prevent premature wear of the hose NOTICE DO NOT lift tank by the valve Lifting the tank by the valve may result in damage to the valve One Year Limited Warranty 1 Duration The manufacturer warrants that it will repair at no charge for parts or labor the Propane Torch proven defective in material or workmanship during the first year after the date of original purchase 2 Who Gives this Warranty Warrantor Campbell Hausfeld The Scott Fetzer Company 100 Production Drive Harrison OH 45030 Telephone 513 367 4811 3 Who receives this Warranty Purchaser The original purchaser of the Campbell Hausfeld product 4 What is covered under this warranty Defects in material and workmanship which occur within the warranty period of one year This warranty extends to the torch hose and fittings only 5 What is not covered under this warranty a Implied warranties including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THIS EXPRESS WARRANTY After this period all risks of loss from whatever reason shall be on the purchaser b ANY INCIDENTAL INDIRECT OR CONSEQUENTIAL LOSS DAMAGE OR EXPENSE THAT MAY RESULT FROM ANY DEFECT FAILURE OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT Some states do not allow limitations on how long an implied warranty lasts so
21. water or leak test solution 4 Ignite the torch according to lighting instructions Check operation of adjusting valve and all other components prior to proceeding Periodically 1 Remove any debris or combustible www chpower com Propane Torch Kit Maintenance cont material from torch The torch must be kept clear and free of combustible materials 2 The surface of the device should be cleaned with soap and water Do not use petroleum based or flammable cleaner on any part of the device Disconnecting the Supply LP Tank 1 Make sure supply tank valve is shut off 2 Open torch adjusting valve s briefly to release any residual gas left in the hose 3 Close adjusting valve 4 Disconnect the POL nut nipple located at end of hose assembly from supply tank by turning clockwise with adjustable wrench Storage Never store a torch that is hot When the torch is stored indoors the connection between LP gas tank and device must be disconnected Also the tank must be removed from the device and stored outdoors in accordance with Chapter 5 of the Standard for the storage and handling of liquefied petroleum gasses ANSI NFPA 58 When storing place tank on a level surface in an upright position Do not invert or lay tank on its side Storage AWARNING temperature must not exceed 120 F 49 3 C DO NOT smoke AWARNING around or expose supply tank to open flames or sparks The h
Download Pdf Manuals
Related Search
Related Contents
Tungsten Bedienungsanleitung - heizstrahler Foxconn NetBox-N270 Cabstone 95122 soundbar speaker Agenda Digital Personal - Franklin Electronic Publishers, Inc. MacroVue UV-20 STEUERUNG DA321G5321 BETRIEBSANLEITUNG Sect. 08 Cos1_corr - Patterson Dental/Dentaire Fenix HL22 flashlight Copyright © All rights reserved.
Failed to retrieve file