Home

Beko LG-BKE 6450 D, LG-BKE 6500 D, LG-BKE 6600 D, LG-BKE 6700D, LG

image

Contents

1. e It contains contaminants and will make you sick Owner s Manual 5 Prior to operation Il Prior to operation Preparing for ope 1 Contact an installation specialist for installation 2 Plug in the power plug properly 3 Use a dedicated circuit 4 Do not use an extension cord 5 Do not start stop operation by plugging unplugging the power cord 6 If the cord plug is damaged replace it with only an authorized replacement part 1 Being exposed to direct airflow for an extended period of time could be hazardous to your health Do not expose occupants pets or plants to direct airflow for extended periods of time 2 Due to the possibility of oxygen deficiency ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g preserving precision devices food pets plants and art objects Such usage could damage the items Cleaning and mai 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and breaker are turned off The fan rotates at a very high speed during operation There is a possibility of injury if the unit s power is accidentally triggered on while cleanin
2. original position After removing the air filters pull slightly forward to remove the TRIPLE DEODORIZING filter Dry in the sunlight for two hours Re install the TRIPLE DEODORIZING filter to the original position Maintenance and Service Replacement of Purifying Filter Optional Recomended use period About 2 years 4 Open front panel and remove air Remove Triple deodorizing Filters filters 8 Insert new Triple deodorizing Filters Air filter panel Triple Deodorizing Filter The heat exchanger coils and panel vents of the outdoor unit should be checked regularly If clogged with dirt or soot the heat exchanger and panel vents may be professionally steam cleaned Air intake 4 vents NOTICE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs Piping Drain Hose Air outlet vents Owner s Manual 21 Maintenance and Service When the air conditioner is not going to Operate the air conditioner on mode for 2 to 7 Clean the air filter and install it in the indoor 3 hours unit Refer to page 20 for cleaning filters e This will dry out the internal mechanisms 2 Turn off the circuit breaker and disconnect the plug Check that the air inlet and outlet of the indoor outdoor unit are not blocked CAUTION Turn off the circuit breaker when the air conditioner is not going to be used for a long time Dirt
3. AWARNING E Installation Plug in the power plug properly e Otherwise it will cause electric shock or fire due to heat generation or electric shock Do not modify power cord length or share the outlet with other appliances e It will cause electric shock or fire due to heat generation Always install air leakage breaker and a dedicated switching board e No installation may cause fire and electric shock accident Keep firearms away It may cause fire Do not damage or use an unspecified power cord It will cause electric shock or fire In the supply cord is damaged it mut be replaced by the manufacturer or its service agent or a similarly quallfied person in order to avoid a hazard Y Attachment Always perform grounding work No grounding may cause electric shock Do not use the socket if it is loose or damaged It may cause fire and electric shock Owner s Manual 3 Safety Precautions E Operation Do not operate or stop the unit by inserting or pulling out the power plug e It will cause electric shock or fire due to heat generation Do not operate with wet hands or in damp environment It may cause electric shock Unplug the unit if strange sounds smell or smoke comes from it It may cause fire and electric shock accident Do not use the power cord close to the heating tools It may cause fire and electric shock Ventilate before operating air conditio
4. LG BEKO Room Air Conditioner OWNER S MANUAL Models LG BKE 6450 D LG BKE 6500 D LG BKE 6600 D LG BKE 6700 D LG BKE 6800 D Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 6055 3 Norm IMPORTANT Please read this owner s manual carefully and thoroughly before installing and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly Room Air Conditioner Owner s Manual TABLE OF CONTENTS Safety Precautions 3 F O R YO U R R ECO R DS Prior to Operation sss 6 2 Write the model and serial numbers here 2 Model Operating Instructions 7 Serial Remote Controller 7 You can find them on a label on the side of each unit Dealer s Name Date Purchased Additional features 17 Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues Remote Control Operation 8 Maintenance and Service 20 Indoor unit 20 pP READ THIS MANUAL Outdoor unit 21 Inside you will find many helpful hints on how to use and 3 3 maintain your air conditioner properly Just a little Operation Tips SOTA ROSE HE 22 preventive care on your part can save you a great deal P of time and money over the life of your air conditioner Troubleshooting 23 y 4
5. may collect and may cause a fire 3 Remove the batteries from the remote control Operation Tips This is not good for the health and wastes electricity Avoid opening doors and windows as much as possible to keep the cool air in the room 22 Room Air Conditioner Do not let direct sunshine enter the room when the air conditioner is in operation Blockages in the air filter reduces the airflow and lowers the cooling and dehumidifying effects Clean at least once in every two weeks Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Since windows are kept closed it is a good idea to open them and ventilate the room now and then Maintenance and Service Check the following points before requesting repairs or service If the fault persists please contact your dealer or service center Case Explanation See page The air conditioner does not Have you made a mistake in timer operation 17 operate Has the fuse blown or has the circuit breaker been tripped The room has a peculiar Check that this is not a damp smell exuded by odor the walls carpet furniture or cloth items in the z room It seems that condensation Condensation occurs when the airflow from is leaking from the air the air conditioner cools the warm room air conditioner Air conditioner does not This is the protector of the mechanism ope
6. You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all A PRECAUTION Contact the authorized service technician for repair or maintenance of this unit e Contact the installer for installation of this unit e The air conditioner is not intended for use by young children or invalids without supervision e Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only 2 Room Air Conditioner Safety Precautions I Safety Precautions To prevent injury to the user or other people and property damage the following instructions must be followed E incorrect operation due to ignoring instruction will cause harm or damage The seriousness is classified by the following indications AWARN ING__ This symbol indicates the possibility of death or serious injury i A C AUTION This symbol indicates the possibility of injury or damage to properties only E Meanings of symbols used in this manual are as shown below O Be sure not to do i Be sure to follow the instruction
7. djust the time See page 17 TIMER SET CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation See page 17 SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation See page 17 AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating See page 19 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature PLASMA OPTIONAL Used to start or stop the plasma purification function See page 15 HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON NOT ON ALL MODELS Used to set the desired horizontal airflow direction See page 18 RESET BUTTON Used prior to resetting time or after replacing atteries nd F Button sed prior to using modes printed in blue at the bottom of buttons See page 16 AUTO CLEAN OPTIONAL Used to set Auto Clean mode CN O Operating Instructions SIZ Cooling Operation Press the Start Stop button The unit will respond with a beep m Z 7 T 2 Open the door on the remote control To select Cooling Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow AO Cooling Auto Healthy Heating Dehumidiication Heat pump mok only vo 8 lt gt PLA Close the door on the remote control Set the temperature lower than the room temperature The temperature can b
8. e set within a range of 18 C 30 C in 1 C increments To raise the temperature To lower the temperature Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shifted Natural wind by the CHAOS logic Oi For more fresh feeling than other fan speed press the Indoor Fan Speed Selector and set to CHAOS mode In this mode the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic Owner s Manual 9 Operating Instructions Auto Operation Optional Press the Start Stop button The unit will respond with a beep Open the door on the remote control To select Auto Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow Ah HH 8 3B aot anu Cooling Auto Healthy Heating Dehumiication Heat pump now only The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature If you want to change the set temperature press the Room Temperature Setting buttons The cooler or warmer you feel the more times up to two times you should press the button The set temperature will be changed automatically To raise the temperature To lower the tem
9. eed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shifted Natural wind by the CHAOS logic Q For more fresh feeling than other fan speed press the Indoor Fan Speed Selector and set to CHAOS mode In this mode the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic Owner s Manual 13 Operating Instructions Jet Cool Operation Press the Start Stop button The unit will respond with a beep Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes For this operation Pe appears on the display Plasma model only To cancel the Jet Cool mode press the Jet Cool button or the fan speed button or the room temperature setting button again and the unit will operate in high fan speed on cooling mode EX aS 5 penn KA or or CIS NOTICE Q During the JET COOL function at any moment the A C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp automatically to 18 C It is especially used to cool the room temp in the shortest time in a hot summer In heat pump mode or neuro fuzzy mode however the JET COOL function is not available 1 In order to return to the normal cooling mode from the JET COOL mode you just press either the operation mode selection button airflow v
10. filters behind front panel Vertical louver Horizontal louver AIR FILTERS The air filters behind the front grille should be checked and cleaned once in every 2 weeks or more often if neccessary Air inlet vent Air outlet vent Vr NANO PLASMA FILTER TRIPLE DEODORIZING FILTER OPTIONAL The PLASMA filter behind the air filters should be checked and cleaned once in every 3 months or more often if necessary NANO PLASMA Filter Don t touch this PLASMA Filter within 10 seconds after opening the inlet grille it may cause an electric shock A 20 Room Air Conditioner T Never use any of the followings e Water hotter than 40 C Could cause deformation and or discoloration Volatile substances Could damage the surfaces of the air conditioner lt Gasoline 0 Lift the front access panel and pull the filter tab slightly forward to remove the filter Clean the filter with a vacuum cleaner or warm soapy water e If dirt is conspicuous wash with a solution of detergent in lukewarm water e If hot water 40 C or more is used it may be deformed After washing with water dry well in the shade O Re install the air filter 1 After removing the air filters pull slightly forward to remove the NANO PLASMA filter Remove dust with vacuum cleaner or air You should not try to wash with water 6 Note the cuts of electric discharge lines Re install the NANO PLASMA filter to the
11. g inner parts of the unit For repair and maintenance contact your authorized service dealer Symbols Used in this A This symbol alerts you to the risk of electric shock This symbol alerts you to hazards that could cause harm to the A air conditioner This symbol indicates special notes 6 Room Air Conditioner Operating Instructions I Operating Instructions cung Z Remove the battery cover by pulling it according to the arrow direction 2 Insert new batteries making sure that the and of battery are installed correctly Reattach the cover by sliding it back into position Use 2 AAA 1 5volt batteries Do not use rechargeable batteries Storage and Tips For Using the Remote Control The remote control may be stored by mounting it on a To operate the room air conditioner aim the remote wall control at the signal receptor Signal Receptor Receives the signals from the remote control Signal receiving sound two short beeps or one long beep Operation Indication Lamps D On Off Lights up during the system operation SX Sleep Mode Lights up during Sleep Mode Auto operation Timer Lights up during Timer operation Lights up during Sleep Mode Auto operation Defrost Mode Lights up during Defrost Mode or Hot Start operation Heat pump model only OUT OUTDOOR UNIT Lights up during outdoor unit operation DOOR OPERATION Cooling model only ON INDOOR UNIT L
12. ights up during indoor unit operation Optional receptor OF ERATION Operation indication lamps mye Indicates the setting temperature ou Plasma model only Plasma Lights up during plasma operation Plasma model only Owner s Manual 7 Operating Instructions The remote control transmits the signals to the system m Signal transmitter Flip up door opened Operation Mode Cooling Operation uF Auto Operation or Auto Changeover A uF Healthy Dehumidification Operation g Heating Operation Cooling Model lt Heat Pump Model 8 Room Air Conditioner 2 0000 090090 Q 90 START STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again OPERATION MODE SELECTION BUTTON Used to select the operation mode ROOM TEMPERATURE SETTING La BUTTONS ALS Used to select the room temperature INDOOR FAN SPEED SELECTOR 0 RAON O Used to select fan speed in four steps low medium high and CHAOS lt gt JET COOL Used to start or stop the speed amp cooling Speed cooling operates CD super high fan speed in cooling mode CHAOS SWING BUTTON Ks Used to stop or start louver movement and AS set the desired up down airflow direction Co ON OFF TIMER BUTTONS OPTIONAL Used to set the time of starting and stopping operation See page 17 TIME SETTING BUTTONS Used to a
13. in blue at bottom of buttons Check the indication of 2nd function on remote control display These buttons operate the timer setting as follows 2nd function goes off in a short time automatically or when the button is pressed again For more details refer to functions next page Operating Instructions Ii Additional features e Sleep Mode Press the Sleep Mode Auto button to setthe 4 To cancel the Sleep Mode press the sleep time you want the unit to turn off automatically Mode Auto button several times until the star w disappears from the operation display The Timer is programmed in one hour increments by pressing the Sleep Mode Auto button 1 to 7 times The sleep mode is available for 1 to 7 times To alter the time period in steps of 1 hour press the Sleep Mode Button while aiming at air conditioner Make sure the Sleep Mode Auto LED lights up Setting the Time Time can be set only when you have pressed Press the Time Setting buttons until the the Reset button If you have just replaced the desired time is set Eu ea batteries the Reset button should be pressed RN to reset the time og 3 Press the Start Stop button f O Press the Timer SET button Omo Press 2nd F button OSE and check if 2nd F icon is on Moy Check the indicator for A M an PM Owner s Manual 17 Operating Instructions Ag Vertical Airflow Direction Control The up down airflow Vertical Airfl
14. ith a beep Open the door on the remote control Press the Air Circulation button Close the door on the remote control Now each time that you press the Indoor Fan Speed Selector the fan speed is shifted from low to CHAOS and back to low again H F P F F F m ad LLL CHAOS Air Fan speed is on low Fan speed is on medium Fan speed is on high NOTICE LI CHAOS Air economizes power consumption and prevents overcooling The fan speed is automatically changed from high to low or vice versa depending on the ambient temperature Q Forced Operation Operation procedures when the remote control can t be used The operation will be started if the power button is pressed If you want to stop operation re press the button Open the front X panel upward j Heat pump Model Cooling Model Room Temp 24 C 21 C Room Temp lt 24 C Room Temp lt 21 C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan regardless of room temperature and resets in 18 minutes During test operation if remote controller signal is received the unit operates as remote controller sets If you want to use this operation open the front panel upward and Press the power bu
15. ner when gas goes out It may cause explosion fire and burn Do not allow water to run into electric parts It may cause failure of machine or electric shock Do not direct airflow at room occupants only e This could damage your health Do not open the entrance during operation It may cause electric shock Do not use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc It may cause an explosion or fire Do not disassemble or modify products randomly It may cause failure and electric shock A CAUTION E Installation Ensure that an installation console of the outdoor appliance is not damaged due to the use for a long time If leaving appliance damaged there is concern of damage due to the falling of product 4 Room Air Conditioner Use caution when unpacking and installing Sharp edges could cause injury Safety Precautions E Operation Never touch the metal parts of the unit when removing the filter They are sharp and may cause injury Ventilate well when used together with a stove etc An oxygen shortage may occur Do not put a pet or house plant where it will be exposed to direct air flow e This could injure the pet or plant Stop operation and close the window in storm or hurricane e Operation with windows opened may cause wetting of indoor and soaking of household furniture Turn off the main power switch when not
16. olume selection or temp setting button or the JET COOL button again 14 Room Air Conditioner Operating Instructions PLASMA Purification Operation Optional Press the Start Stop button The unit will respond with a beep m Z a im T Open the door on the remote control Press the PLASMA air purifying o eration ONOFE button butoni peration will start when the button is pressed and stop when the button is pressed again 8 Wc PLLA Make sure the plasma led lights up Set the fan speed again with door of the remote control closed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Air purifying operation PLASMA can be with cooling Heating or any other operations PLASMA Air Purifying Operation only If you press the only PLASMA button only PLASMA air purifying operates gt Then fan speed is low You can select the fan m speed in four steps low medium high or CHAOS Each time the button 9 is pressed the fan speed mode is shifted Owner s Manual 15 Operating Instructions Santil OFF EnA N 16 Room Air Conditioner 2nd F Operation Press the Start Stop button The unit will respond with a beep Open the door of the remote control and press the 2nd Function button to operate functions printed
17. ow can be NOTICE adjusted by using Ine emote control 4 If you press the CHAOS swing button at first 5 cycles the horizontal louver will swing up and down at maximum angle Then the vertical airflow direction is changed oN automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make w the human body feel most comportable as if enjoying a natural breeze 1 Always use the remote control to adjust the up down airflow direction Manually moving the 0 Press the Start Stop button to start the unit 2 Press Chaos Swing button and the louvers will vertical airflow direction louver by hand could swing up and down Press the Chaos Swing damage the air conditioner button again to set the horizontal louver at the T When the unit is shut off the up down airflow desired airflow direction Ws direction louver will close the air outlet vent of the Q N system To adjust left right Horizontal Airflow direction Caution Ensure that the unit is turned off before adjusting the horizontal airflow direction control Carefully open vertical louver to allow access to the horizontal airflow direction Adjust the left right airflow direction by hand af Auto Clean 0 Whenever you press the Auto Clean button Auto Clean Function will be reserved and AUTO CLEAN cancelled Auto Clean function works before and after cooling or dehumidification mode For details refer to the below point
18. perature For this operation A 7 appears on the display Cooling plasma model only During Auto Operation Q You cannot switch the indoor fan speed It has already been set by the Fuzzy rule I If the system is not operating as desired manually switch to another mode The system will not automatically switch from the cooling mode to the heating mode or from heating mode to cooling mode it must be done by manually resetting During Auto Operation pressing the chaos swing button makes the horizontal louvers swing up and down automatically If you want to stop auto swing press the chaos swing button again 10 Room Air Conditioner Operating Instructions Auto Changeover Operation Optional Press the Start Stop button The unit will respond with a beep m Z a C ey T Open the door on the remote control To select Auto Changeover Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow ce PLA Fall 8 cab 3g a PA Cooling Healthy Heating changeover Dehumidiication Heat pump model only Close the door on the remote control Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C in 1 C increments To raise the temperature To lower the temperature Set the fan speed again with the door of the remote control s
19. rate for about 3 minutes Wait about three minutes and operation will when restarted begin Does not cool or heat Is the air filter dirty See air filter cleaning 20 effectively instructions Has the temperature been set incorrectly 9 13 Are the indoor unit s air inlet or outlet vents obstructed The air conditioner For a noise that sounds like water flowing operation is noisy This is the sound of freon flowing inside the air conditioner unit e For a noise that sounds like the compressed air releasing into atmosphere This is the sound of the dehumidifying water being processed inside the air conditioning unit Remote control display is Are the batteries depleted faint or no display at all Are the batteries inserted in the opposite 7 and directions Crack sound is heard e This sound is generated by the expansion constriction of the front panel etc due to changes of temperature Owner s Manual 23
20. s When the unit is started after the reservation of Auto Clean the Cool Start function operates and indoor Fan is started after 20 seconds O When you press Start Stop button to turn off the unit after the you have reserved Auto Clean function the air conditioner circulates the indoor air in the Auto Clean mode with no more Cooling or Dehumidification operation For Cooling only model it lasts for 30 minutes for Heat pump model for 16 minutes O If you press the auto clean button again during the product operation Auto Clean function will be cancelled For this operation o appears on the display Plasma model only NOTICE Q This function is to remove unpleasant smells from mold and other bacteria in the air conditioner and to remove humidity automatically during humidly summer which supplies the indoor with purified air Horizontal Airflow Direction Control Optional The left right Horizontal Airflow can be adjusted by using the remote control Press the Start Stop button to start the unit Open the door on the remote control Press the Airflow Direction Start Stop button and the louvers will swing left and right Press the Horizontal Airflow Direction Control Button again to set the vertical louver at the desired airflow direction 18 Room Air Conditioner Operating Instructions Air Circulation Mode Circulates the room air without cooling or heating 4 Press the Start Stop button the unit will respond w
21. till closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shifted During Auto changeover Operation The air conditioner changes the operation mode automatically to keep indoor temperature When room temperature vary over 2 C with respect to setting temperature air conditioner keeps the room temperature in 2 C with respect to setting temperature by auto changeover mode Owner s Manual 11 Operating Instructions Press the Start Stop button The unit will respond with a beep Open the door on the remote control To select Healthy Dehumidification Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow KAON Am Cooling Auto Healthy Heating Dehumidication Heat Hee only Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Natural wind by the CHAOS logic l For more fresh feeling than other fan speed press the Indoor Fan Speed Selector and set to CHAOS mode In this mode the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic During Healthy Dehumidification Operation If you select the dehumidification mode on the opera
22. tion selection button the A C starts to run the dehumidification function It automatically sets the room temp and airflow volume to the best condition for dehumidification based on the sensed current room temp In this case however the setting temp is not displayed in the remote control and you are not able to control the room temp either During the healthy dehumidification function the airflow volume is automatically set according to the optimization algorithm responding to the current room temp status which makes the room condition healthy and comfortable even in the high humidity season 12 Room Air Conditioner Operating Instructions Heating Operation Heat pump model only Press the Start Stop button The unit will respond with a beep m Z e 7p I Open the door on the remote control To select Heating Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow sri F Ahle uuill aie E Cooling Auto Healthy Heating Dehumidiication Heat pump m only Close the door on the remote control Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in 1 C increments To raise the temperature To lower the temperature Set the fan speed again with the door of the remote control still closed You can select the fan sp
23. tton let it be pressed for about 3 seconds If you want to stop the operation re press the button For this operation Lo appears on the display Plasma model only Auto restart O ptional In case the power comes on again after a power failure Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions So there is no need of activating this function by pressing any key or button In the initial mode the fan operates at a low speed and the compressor starts 2 5 3 minutes later As the compressor starts the fan speed also resumes its previous setting mode Additionally in order to cancel auto restart operation press power button let it be pressed for about 6 seconds To operate auto restart operation again press power button for about 6 seconds as well Helpful information Fan speed and cooling capacity The cooling capacity indicated in the specification is the value when the fan High fan speed is recommended when you wish to cool the room quickly Owner s Manual 19 Maintenance and Service Ii Maintenance and Service CAUTION Before performing any maintenance turn off the main power to the system Grille Case and Remote Control 4 Turn the system off before cleaning To clean wipe with a soft dry cloth Do not use bleach or abrasives IONA Supply power must be disconnected before cleaning the indoor unit ED Air
24. using it for a long time It may cause failure of product or fire Always insert the filters securely Clean it once every two weeks e Operation without filters may cause failure Do not place heavy object on the power cord and take care so that the cord should not be pressed There is danger of fire or electric shock If water enters the product turn the power switch of the main body of appliance off After taking the power plug out from the socket contact with the service center Do not clean the air conditioner with water Water may enter the unit and degrade the insulation It may cause an electric shock When cleaning the unit first make sure the power and breaker are turned off Since the fan rotates at high speed during operation it may cause injury Do not use appliance for special purpose such as animals or vegetables precision machine or conservation of art articles It may cause damage of animals or vegetables or loss of property Hold the plug by the head of the power plug when taking it out It may cause electric shock and damage Do not place obstacles around the absorption inlet or instead of blowing out inlet It may cause failure of appliance or accident Do not use strong detergent such as wax or thinner but use a soft cloth Appearance may be deteriorated due to change of product color or scratching of its surface Do not drink water drained from air conditioner