Home

APC PER5T-CH Surge Protector User Manual

image

Contents

1. CEE7 7 CEE7 16 AS3112 ve BSI1363 H OIS 8303 GB2099 1 10A Model PerST CH Model Net5N CH 10BaseT 100BaseT 100BaseTX 100BaseT4 100VG AnyLAN ISDN SurgeArrest D SurgeArrest 10 Amp ro ot Jom 1 0O HF 2 O 250VAC
2. APC APC RMA SurgeArrest RMA APC JE FYE 100088 25 513 86 10 6201 6688 86 10 6201 7658 American Power Conversion 132 Fairgrounds Road West Kingston Rhode Island 02892 USA http www apcc com
3. 3 SurgeArrest 4 Model PerST CH SurgeArrest IN SurgeArrest OUT 132 mm 5 2 in 5 Model NetSN CH LAN SurgeArrest IN SurgeArrest OUT SurgeArrest 7 ON 3 E3 SurgeArrest SurgeArrest
4. 11 43 cm 3 5 mm 20 C 0 C 40 C 250 VAC 230 VAC nom 50 60 Hz 0 95 CCEE APC 1 15 55 dB 30 70 dB 100kHz 10MHz Cat A 6KV lt 8 5 lt 1 5 315J 630J k 5 5kA 11kA 8x20us 11kA 22kA 2 326vpC emanes O O o o o oS aloe EREE ee GW O a 3 reer w EIA TIA 568 Category 5 American Power Conversion SurgeArrest APC
5. SurgeArrest EAEL gt SurgeArrest SurgeArrest 250 VAC 50 60 Hz 10 Amps gt SurgeArrest 1 O SurgeArrest A CRE APC AE SurgeArrest
6. SurgeArrest P Thank you for selecting APC SurgeArrest It has been designed to provide the highest value of protection against spikes and EMI RFI noise on electrical lines Save these instructions for future reference a SAFETY PRECAUTIONS gt Do not install this device during a lightning storm gt The SurgeArrest is intended for a cool 0 40 C and dry indoor environment with relative humidity of 0 95 non condensing Do not install the SurgeArrest near heaters or in a hot environment Do not install the SurgeArrest in an excessively moist or potentially wet environment for example near bathtub sinks pools etc gt The SurgeArrest is intended to supply electric power to computers peripheral and electronic equipment The SurgeArrest is rated for 250 VAC 50 60 Hz and 10 Amps maximum gt For best protection against spikes induced by lightning storms it is hightly recommended that the SurgeArrest surge suppressor be grounded to earth The Building Wiring Fault indicator red is lit when there is either no ground circuit a reversed polarity in the building wiring or the neutral circuit is overloaded If it lights consult a qualified electrician to examine the building wiring Note When the SurgeArrest is fully loaded this indicator may flicker This is normal and may not be indicative of a fault Five Safety Outlets are provided for your convenience These outlets accept a number of different plugs inclu
7. ber 990 0070 Rev 2 5 99 Figure 2 Installation Instructions 1 Turn OFF Power Switch The switch lever marked with the O should be down 2 Connect the Power Cord to a 250VAC receptacle It is highly recommended that a grounded receptacle be used Please note that ungrounded surge protectors do not provide effective surge protection between line and ground Check local electrical laws governing grounding practices 3 Connect power cords of electrical equipment to be protected into the Outlets on the SurgeArrest 4 For model PerST CH protect your telephone fax machine or modem by connecting the supplied telephone extension cord to the telephone jack on the wall and connecting the other end to the jack marked IN on the SurgeArrest Connect your telephone equipment cord to the jack marked OUT on the SurgeArrest 132 mm 5 2 in Wall Mounting Template 5 For model Net5N CH protect your local area network card by connecting the LAN cable from the Concentrator HUB to the IN jack on the SurgeArrest Connect one end of the supplied cable to the network card jack and connect the other end to the OUT jack on the SurgeArrest 6 Turn ON the SurgeArrest power switch 7 Turn ON connected equipment Note Installation example is shown in Figure 3 Figure 3 Mounting the SurgeArrest on a wall The SurgeArrest has two mounting holes located on the bottom of the unit These holes were des
8. ding those in use in Continental Europe CEE7 7 and CEE7 16 Australia AS3112 the United Kingdom BSI1363 Japan JIS 8303 and China GB2099 1 Note The rated current of each plug should be 10A or less Telephone Protector Network Port Protector Model PerST CH is the only model with a built in one line two wire telephone protector A six foot telephone extension cord is provided Model Net5N CH is the only model with a built in Network Port Protector for 1OBaseT 100BaseT 100BaseTX 100BaseT4 1O0OVG AnyLAN amp Token Ring interface cards amp HUBs Note Never connect an ISDN line to a SurgeArrest D Each SurgeArrest is equipped with a 10 Amp circuit breaker to protect against electrical power overload Button will pop up in the event of an overload If this happens unplug at least one piece of equipment and reset button Figure 1 Product Features Please refer to Figure 1 for the following information and instructions CD The Power Cord is designed for a three wire grounded system Each SurgeArrest has a built in recessed ON OFF Power Switch to allow the user to activate electricity to connected equipment such as computers printers terminals etc The Protection Working A indicator green is illuminated as long as the thermal fuse is intact If this indicator is extinguished the product disconnects from the utility line In this case return this unit to APC for repair or replacement Part Num
9. e suppressors APC warrants its products to be free from defects in materials and workmanship under normal use and service for two years for the original purchaser Its obligation under this warranty is limited to repairing or replacing at its sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from APC or an APC service center with transportation charges prepaid and must be accompanied by a brief description of the problem and proof of date of purchase This warranty applies only to the original purchaser Customer Service Technical Support APC China RM 513 Haowei Building No 25 Beitaipingzhuang Road Haidian District Beijing 100088 People s Republic of China Phone 86 10 6201 6688 Fax 86 10 6201 7658 American Power Conversion 132 Fairgrounds Road West Kingston Rhode Island 02892 USA Internet Address http www apcc com SurgeArrest a BU RIAFEAPC SurgeArrest AP HI tf Ae a ML HIRE MERTE BEE EB ERIE EE BRAR Sf DOR Ft N gt gt SurgeArrest 0 C 40 C SEA 0 95 SurgeArrest
10. igned to hook on to screw heads or nail heads The spacing between the center of the screw holes is 11 43 cm For best results when fastening screws or nails into a wall leave about 3 5 mm spacing between the wall and the bottom flange of the screw or nail Specifications Unless otherwise stated ratings are based on ambient temperature of 20 C Operating Temperature Range O C to 40 C Operating Voltage 250 VAC 230 VAC nom 50 60 Hz Operating Relative Humidity 0 95 non condensing Safety Approval CCEE For more a detailed specification contact APC Table 1 AC Surge Performance Ratings Parameter Model Personal Network EMI RFI Noise Rejection 100kHz to 15 55 dB 30 70 dB 10MHz Cat A Normal Mode Let Through Voltage lt 8 5 lt 1 5 of 6kV pulse Total Energy Capacity 3155 630J Peak Surge Current with 8x20us pulse 5 5kA 11kA Normal Mode Peak Surge Current with 8x20us pulse 11kA 22kA Common Mode Table 2 Telephone Protector Ratings Parameter Model Personal Network Operating Voltage 260V DC Peak Surge Current with 8x20us pulse 4500A All Modes Number of Lines 1 Protected Connector Type RJ1l sow Table 3 Network Protector Ratings Parameter Model Personal Network Operating Voltage 8VDC EIA TIA 568 Category Performance 5 Connector Type RJ45 Limited Product Warranty American Power Conversion offers a limited two year warranty on SurgeArrest surg

Download Pdf Manuals

image

Related Search

Related Contents

97050579(3)_A5-A6plus 2013.indd  Samsung 460P 用户手册  user manual ncsu concrete materials database program  Chapitre 3  Samsung Galaxy Young 2 Manual de utilizare  American Standard Two and Three Handle Bath/Shower 7220.700 SERIES User's Manual  G1 Charger  Manual del Usuario Arquetipo Activos Fijos 2.0  Untitled - Boss Audio Systems  Hybrid PV Inverter User Manual  