1.   Insert POWER CORD CONNECTOR   13  through POWER SUPPLY GROMMET  12   Insert  POWER CORD  14  into SPLIT PLUG  11   Push  SPLIT PLUG  11  into POWER SUPPLY GROMMET   12  to seal  Fig  2g     7  Insert POWER SUPPLY CONNECTOR  13  into  RECEPTOR  15  on the CIRCUIT BOARD  3   Fig  2c     8  Install CIRCUIT BOARD  3  into ENCLOSURE  5   with SENSOR WIRE  7  under BOARD  Fig  2d     9  Insert SENSOR WIRE CONNECTOR  8  into  CIRCUIT BOARD RECEPTOR  10  slot  Fig  2f     10  Connect wires from SENSOR to SOLENOID  VALVE  6   Red to    Black to     Fig  2d     11  Replace ENCLOSURE COVER  1   Tighten cover  screws firmly           Fig  3  Unit 1   Unit 2 Unit  3                   TWO PIECE  a oa GROMMET                                     E  FOR AC VERSION Fig  4a   MULTI HOOK UP   Fig  3  4  1  See AC Version Electrical Hook up for first unit of CROMER 8    the Multi hook up     2  Remove ENCLOSURE COVERS from all  ENCLOSURES     3  Remove SOLID BLACK INSERT 1  from right side  of ENCLOSURE  1 and replace with gray 2 PIECE  GROMMET  3   Replace solid black inserts on Unit  2  with gray 2 PIECE GROMMET  3      4  Take the 10 ft  EXTENSION  2  from Unit  2 and  install into right side of Unit  1 and Left side of Unit  2  insealing wire into SPLIT PLUG  7  as shown in Fig  4a     Push SPLIT PLUG  7  into GROMMET  8   Feed the gray 8 ft  EXTENSION  2  through ROUND    5  Insert CONNECTOR from 10 ft  EXTENSION  2  GROMMETS  3  and U GROMMETS  5  as illustrated above   into CIRCUIT BOARD
2.  RECEPTOR  4  top of Unit  1  as shown in Fig  3     6  Insert other end of 10 ft  EXTENSION into LOWER  U GROMMET  5  of Unit  2  approximately 4  from  connector   Fig  3  Push SPLIT PLUG  7  into  GROMMET  8  to seal     7  Insert connector of 10 ft  EXTENSION into lower  receptor as shown in fig  3 on CIRCUIT BOARD  6  of  Unit  2     8  Feed gray sensor wire 9 from Unit  2 through upper  U GROMMET  10  of Unit  2 ENCLOSURE 4  from  connector Fig  3  Insert wire into SPLIT PLUG  7    Push SPLIT PLUG  7  into GROMMET  8  to seal  Fig  4a     9  Insert GROMMET  2  back into ENCLOSURE  Fig  4b     10  Reinstall Circuit Board  3  into Enclosure with all  wires under Board  Fig  4b     11  Connect Unit  2 Red and Black Sensor wires To   2 solenoid valve  Red to    Black to     Fig  4b        12  Repeat Steps 3 through 11 for remaining Units in  Multi Hook up        MAINTENANCE       fh  HAND WASH SENSOR OPERATION   Fig  1    When the Sensor detects a user  the water  immediately starts to flow  Water flow will stop Two  seconds after user is out of sensor range  The off  delay allows the user to comfortably move his hands  without the flow cycling on to off  As a precaution  a  safety timer will turn off the water  after the sensor has  been blocked for 59 seconds  The water will stay off  until the blockage is removed from the detection zone     Detection Zone  2    10   50mm   250mm   Default  Set at Factory 6   150mm     A HOW TO CHANGE SENSOR  RANGE   Factory set at 6   Fi
3. ELECTRICAL INSTALLATION      DC VERSION  BATTERY   Fig  1    1  Remove ENCLOSURE COVER  1   Fig  1     2  Feed the WIRE CONNECTORS  2  through the top  of ENCLOSURE  5   Fig  1a     3  Remove GROMMET  4  from ENCLOSUR  5   Fig 1     4  Feed the gray SENSOR WIRE  7  through  GROMMET  4   4  from CONNECTOR  Fig  1b  amp  1d  Insert gray SENSOR WIRE  7  into SPLIT PLUG  9    Push SPLIT PLUG  9  into GROMMET  4  to seal   Fig  1d     5  Insert GROMMET  4  back into ENCLOSURE  5    Fig  1c     6  Install BATTERY  11  onto DC circuit board  Fig 1e   Note  For BATTERY PACK installation see  Install  Battery  page 7     7  Install CIRCUIT BOARD  3  into ENCLOSURE  5   with SENSOR WIRE  7  under BOARD  Fig  1c     8  Insert SENSOR WIRE CONNECTOR  8  into  CIRCUIT BOARD RECEPTOR  10   Fig  1e     9  Connect wires from SENSOR to SOLENOID VALVE   6   Red to    Black to     Fig  1c     10  Replace ENCLOSURE COVER  1   Tighten cover  screws firmly        H AC VERSION  Fig  2    oP NUTONE Gisconnect AC power supply   1  Remove ENCLOSURE COVER  1   Fig  2     2  Feed the WIRE CONNECTORS  2  through the top  of ENCLOSURE  5   Fig  2a     3  Remove GROMMET  4  from ENCLOSUR  5   Fig  2     4  Feed the gray SENSOR WIRE  7  through  GROMMET  4   4  from CONNECTOR  Fig  2b  Insert  gray SENSOR WIRE  7  into SPLIT PLUG  9   Push  SPLIT PLUG  9  into GROMMET  4  to seal  Fig  2e     5  Insert GROMMET  4  back into ENCLOSURE  5    Fig  2d     6  Remove SPLIT PLUG  11  from POWER SUPPLY  GROMMET  12 
4. LENOID  VALVE ASSEMBLY    M950251 0070A  AC SOLENOID  VALVE ASSEMBLY    M962387 0070A  MOUNTING SCREW KIT    A91 3202 0070A         WASHER A923654 0070A    BATTERY 6VCR P2    A922251 0070A  SOLID GROMMET    A924162 0070A  SUPPLY HOSE    A918462 0070A  SOLENOID SCREWS                 605P400       M962389 0070A    SOLENOID  amp  SCREWS A950487 0070A    CIRCUIT BOARD DC        A950507 0070A  044912 0070A FILTER    MOUNTING NUT A922267 0070A    ROUND GROMMET    A950509 0070A    SUPPLY STOP A922272 0070A    U GROMMET    A922290 0070A  POVVER SUPPLY  GROMMET       Replace the  YYY  with  appropriate finish code    CHROME 002 M950169 0070A  POWER SUPPLY    s nuy    A950489 0070A  CIRCUIT BOARD  AC  amp  MULTI AC              HOT LINE FOR HELP  For toll free information and answers to your questions  call   1  800  442 1902  Weekdays 8 00 a m  to 8 00 p m  EST    A922265 0070A  10 ft  MULTI EXTENSION WIRE   for 6057 series only        IN CANADA 1 800 387 0369  TORONTO 1 905 306 1093   Weekdays 8 00 a m  to 7 00 p m  EST    Product names listed herein are trademarks of American Standard Inc      American Standard Inc  2005    M968809 Rev 1 2    10    Armtricam Standard    M968809 Rev 1 2    
5. O O18 GOD           INSTALLATION    fl INSTALL SPOUT ASSEMBLY   Fig  1   TNO supplies before beginning    1   Optional  Assemble DECK PLATE  1  and PUTTY    PLATE  2  to FAUCET BODY  3  with SCREW  4    Fig  1     2  Insert WIRES  5   FLEX HOSE  6  and SPOUT  SHANK  7  through center hole of mounting surface   Fig  1a     3  Assemble  C  WASHER  8   STAR WASHER  9   and LOCKNUT  10  onto threads of SPOUT SHANK   7  from underside of mounting surface  Fig  1b     4  Align FAUCET  3  and tighten LOCKNUT  10   If   using DECK PLATE  1  hand tighten DECK PLATE   SPIN NUTS  11  to secure FAUCET  3  to mounting  surface  Fig  1b        A MOUNT ENCLOSURE  Fig  2    1  Determine location of ENCLOSURE  1   It must be  located with in the 14   856mm  by 21   533mm   shaded area shown in Figure 2 in order for electrical  connections from the spout assembly to be made   NOTE  ENCLOSURE SUPPLY HOSE is 20   Distance  between wall supply and ENCLOSURE  1  must be  taken into consideration     2  Remove 4 screws from COVER  2  and pull off  COVER  2   Hold the ENCLOSURE  1  in desired  location and mark the four mounting hole locations as  shown  Fig  2     3  The ENCLOSURE  1  works best if secured to a wall  stud or cross brace within the wall  using the SCREWS   3  supplied  If the ENCLOSURE  1  is to be installed on  a tile or plaster wall the ANCHORS  4  and SCREWS   3  should be used     4  For installations on drywall or tiled walls  use  ANCHORS  4  and SCREWS  3  for securing  ENCLO
6. SELECTRONIC     Proximity Faucets       Cast Spout and two  Goose Neck Sizes            Certified to commen ie a etme aera Replacement Parts 10       2005 American Standard    M968809 Rev 1 2    Installation Instructions       American Standard    NOTE TO INSTALLER  Please give this manual to the customer after installation     To learn more about American Standard Faucets visit our website at  www us amstd com or U S   customer s e mail us at  faucetsupport  amstd com       For Parts  Service  Warranty or other Assistance     please call 1 800 442 1902  In Canada  1 800 387 0369      In Toronto Area only  1 905 3061093        Thank you for selecting American Standard   the benchmark of fine quality for over 100 years  To  ensure that your installation proceeds smoothly  please read these instructions carefully before you  begin     U N P AC KI NG All American Standard Faucets Are Water Tested At Our Factory   Some Residual Water May Remain In The Faucet During Shipping     1  Remove the fitting and loose items from the carton  The illustration below shows the fitting and all loose items  after they have been removed from the carton  Some items may be packaged partially assembled to other items     1  Selectronic Spout Assembly   2  Mounting Kit   3  Electrical Enclosure   4  Supply Hose   5a  DC Power Supply  for 6055 series   5b  AC Power Supply  for 6056 series     PRODUCT No s    5c  10 ft  Extension Wire  for 6057 series    6  Circuit board   7  4  Deck plate   optional 
7. SURE  1  to finished wall  Drill four 1 4  dia   holes a minimum of 1 3 4  deep  Insert the four  ANCHORS  4  flush with face of the finished wall   Align the ENCLOSURE  1  and Install the MOUNTING  SCREWS  3   Tighten to secure ENCLOSURE  1  to  mounting surface     E  CONNECT SPOUT HOSE TO  ENCLOSURE  Fig  3    1  Connect SUPPLY NUT  1  from spout assembly to  nipple on top of ENCLOSURE  2   Tighten with  adjustable wrench to make a water tight connection   Fig  3     FE  CONNECT WATER SUPPLY TO  ENCLOSURE AND WALL SUPPLY   Fig  4   ek If using the optional Mixing Valve See Sheet   M968808 for installation instructions     1  Insert FIBER WASHER  4  into SUPPLY NUT  1  on  ENCLOSURE  2      2  Connect SUPPLY NUT  1  on ENCLOSURE  2  to  FLEXIBLE SUPPLY HOSE  3   Tighten to make a  water tight connection  Use two wrenches to tighten if  necessary  Fig  4     3  Connect FLEXIBLE SUPPLY  3  directly to wall  supply  Connection on FLEXIBLE SUPPLY  3  is 3 8   compression  Use adjustable wrench to tighten  connection  Do not over tighten  Fig  4a     Note  FLEXIBLE SUPPLY  3  measures 20  from the  bottom of the ENCLOSURE  1  base  If additional  supply length is required  installer must purchase parts  separately    Important  If FLEXIBLE SUPPLY  3  is too long  loop to  avoid kinking        ENCLOSURE  MOUNTING  HOLES    le 2 3 4        71mm                NOTE  If using Mixing Valve  optional  See Sheet   M968808 for installation instructions                                   
8. cket     5  Pull out the STRAINER  4  and clean with an old  toothbrush  Rinse thoroughly with water     6  Install the STRAINER  4  back in its place and  tighten with a 7 16  socket    Caution  do not over tighten strainer    Note  It is recommended to clean strainer every 6  months     7  Replace ENCLOSURE COVER  Tighten cover  screws firmly     fa HOW TO CLEAN AND REMOVE  THE AERATOR  Fig  5    1  Remove AERATOR HOUSING  1  with KEY  supplied with faucet     3  Remove AERATOR  2  from HOUSING  1      2  Clean the AERATOR SCREENS  3  with a old tooth  brush to remove dirt     4  Rinse Clean with water  Reassemble and install into  spout end  Be sure black seal washer is in place     fi HOW TO CONVERT RIGID GOOSE  NECK SPOUT TO SWING SPOUT  Fig  6   The GN SPOUT is shipped from the factory as a    rigid assembly  To convert the GN SPOUT into a  SWING SPOUT proceed as follows     1  Remove SET SCREW  1  from back of GN SPOUT   A e a UEO   2  with a flat blade screwdriver  Fig  6  x    4 SET SCREW  r FOR SWIVEL  a E   SPOUT   2  Install SWIVEL SET SCREW  3  into opening in the f      GN SPOUT  2   SWIVEL SET SCREW  3  is found in  hardware bag within product box        GENERAL CLEANING  Fig  7    1  For general cleaning use a damp  soft cloth to clean  the spout and the sensor     2  For cleaning dirt use a soft cloth with diluted dish  washing detergent  Wipe the area using a wet cloth  and dry using a soft cloth     Do not scratch the sensor when cleaning     Avoid using an
9. g  2    1  Setting the Detection Zone  Distance    Remove cover from ENCLOSURE  Disconnect GRAY  SENSOR WIRE  1  from circuit board  then reconnect     2  While the SENSOR CONTROL LED  2  is blinking  slowly  place your hand 1   2 in   830 50mm  in front of  the sensor  Fig  2a     3  When the LED stops blinking and stays  ON   move  your hand to the desired position and hold in place  until the LED begins to blink again  Fig  2a     4  Once the SENSOR CONTROL LED  2  begins to  blink again  remove your hand from the detection zone   When the flashing stops  the detection distance is set     ki  HOW TO INSTALL AND CHANGE  BATTERY  Fig  3    1  To install New BATTERY  1  align and press down  BATTERY  1   contacts facing downward  into position  until tabs lock into place     To remove the BATTERY  1  spread the two tabs on  the HOLDER  2  with your thumbs   The BATTERY  1   will release     2  Remove the OLD BATTERY  1    3  Install NEW BATTERY  1   contacts facing    downward  into HOLDER  2  and press down into  position until tabs lock into place              2   30mm   50mm    2 BLINKING  LED    BATTERY HOLDER    LOCKING TABS 7    E  HOW TO CLEAN FILTER  Fig  4  ZATON Gisconnect AC power supply  1  Remove ENCLOSURE COVER     2  Close SUPPLY STOP  5  with 4mm Hex wrench   Note  Keep water flowing out of faucet while shutting off     3  Pull off Red  1  and Black  2  CONNECTORS from Ra ae  SOLENOID VALVE  3       CLEAN  p SCREENS    4  Unthread STRAINER  4  using a 7 16  so
10. must be ordered separately   8  8  Deck plate   optional must be ordered separately   9  Mixing Valve   optional must be ordered separately   10  Key for vandal resistant aerator    PRODUCT No s       5 1 4  GN Spout    PRODUCT No s    inods poiiseg esoouy    Zz    Ajddnsg 1    MmOd 8SooUd    1    6055 105  6055 102    6056 105  6056 102    6057 105  6057 102    6055 155  6055 153    6056 155  6056 153    6057 155  6057 153    6055 165  6055 163    6056 165  6056 163    6057 165  6057 163    JONPOJd 21U01 29   S   y  1  p10 O  MOH       ju  a 6UIS       YUIS   J0H e Huls e  yonpolg eseg                           19 U    J  UI         SJUIS   JOH    PUE o   jeuoldo    eid 499q       eld 49eq    605XTMV    S  Q U  P OD PUL JOH e  SUIS   JOH    PUR          jJeuolNdo  aaqjeA     UIXIN  ane A   UIXIN       Fig  1  Roughing in Dimensions    141mm   5 1 2  MOUNTING  SURFACE      49mm   2     32mm  1 1 4      gt   125mm    e    381mm       i  15     GENERAL DESCRIPTION     Electronic faucet with proximity operation  Vandal resistant solid brass  construction single post mounting  Operates on DC  battery  or AC  permanent power  In line strainer for solenoid is integral  Single inlet 3 8  compression  built in checks  and flexible stainless steel 15  reach inlet hose  for spout connection        TOOLS REQUIRED  Fig  2    Channel Locks   Adjustable Wrench  Plumbers  Putty or Caulking  Phillips Screwdriver   Flat Blade Screwdriver  Electric Drill  amp  1 4  Drill Bit  Tape Measure    N
11. ything that may scratch the spout  surface  Never use polishing power  detergent or a  nylon scrub brush  They will damage the surface of the  spout or Sensor     Q  How will   know if battery needs to be replaced   A  Valve does not open and sensor blinks 2 times  interrupted by pause for up to 7 days     Q  Why has the flow rate of the faucet reduced  significantly   A  Check and clean aerator and strainer     Q  There is no flow out of faucet when I m in the  sensor range    A  Check sensor  If sensor blinks 2 times interrupted  by pause  replace battery  or call 1800 442 1902        Q  Why does the faucet operate the opposite of  expected Turns On when not in sensor range  but  turns off when in sensor range    A  Sensor wires to solenoid are reversed  Black to     amp  Red to   is correct     Q  What is the normal operating pressure range   A  Faucet will operate with supply pressures ranging  from 20 80 psi          SELECTRONIC  Armtrican Standard LAVATORY FAUCETS    PRODUCT NUMBERS  Cast Spout    Cast Spout        M923827 YYYOA 6055 105 6056 105 6057 105  2 2 GPM AERATOR 6055 102 6056 102 6057 102  066508 YYYOA 5 1 4  GN Spout    0 5 GPM AERATOR 6055 155 6056 155 6057 155    6055 153 6056 153 6057 153    M962388 0070A i  SENSOR KIT 6  GN Spout         CCCG    6055 165 6056 165 6057 165  6055 163 6056 163 6057 163       A923672 0070A  FAUCET SUPPLY  HOSE    D   0  ol     N  N  pa          x  r   O  D       M962411 0070A  MOUNTING KIT                 M950250 0070A  DC SO
    