1. Normal supply pressure must be at least 20 psi Toilet leaks a Poor supply line connection Review Step 9 of installation procedure b Poor bowl to tank floor connection Review Step 4 through 7 of installation procedure Toilet does a Tank water level too high Follow instructions to adjust water level not shut off b Float rod or float ball depressed by Readjust float rod tank cover c Flush valve chain too tight holding Readjust chain length as needed flush valve open d Float rod interfering with flush valve closing Follow installation instructions to reduce water control flow rate which will lift lowest position of float rod without affecting water level e Flush valve seat and or flapper worn Replace flapper flush valve assembly as needed or deformed f Sand or debris lodged in water control Shut off water supply Consult a plumber if necessary Noisy Flush a Water control flow rate too restricted a Follow instructions to increase water control flow rate CHINALUX ONE YEAR LIMITED WARRANTY If inspection of this ChinaLux plumbing product within one year after its initial installation confirms that it is defective in materials or workmanship ChinaLux will repair or at its option exchange the product for a similar model This warranty does not apply to local building code compliance Since local building codes vary considerably the purchaser of this product should check with a local bui
2. For residents of the United States warranty information may also be Attention Director of Consumer Affairs obtained by calling the following toll free number 800 442 1902 7301311 100 Rev A
3. of the bolts from time to time to ensure a tight fit 120000 XXX Chinaware cover 7381045 400 0070A Flush Valve 7381044 0070A Fill Valve 7381055 100 0070A Flapper Assembly 738916 102 0070A Refill Tube 7381046 XXX0A Trip Lever 7301310 XXX0A Tank Coupling Kit 034783 XXX0A Bolt Cap Kit TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Does not flush a Water supply valve closed a Open valve and allow water to fill tank b Supply line blocked b Shut off water supply disconnect supply line and inspect all gaskets and washers Reassemble c Flush valve chain too loose or disconnected Readjust chain length as required d Stuck float float rod Adjust to allow free downward movement of float arm e Water control flow rate too restricted Follow instructions to increase water control flow rate REPAIR PARTS LIST Poor or a Tank water level too low Follow instructions to adjust water level sluggish flush b Bowl water level too low Check that refill tube is connected to water control and inserted into tank overflow without being kinked or damaged c Supply valve partly closed Open supply valve fully Be sure that proper supply tube size is used d Flush valve closes early due to high Follow instructions to reduce water control flow rate supply pressure e Partially clogged trapway and or Remove obstruction Consult a plumber if necessary drain pipe and or vent f Supply pressure too low
4. CHINALUX Americam Standard ChinaLux 1000 EL ChinaLux 1000 RF INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE To ensure this product is installed properly please read these instructions carefully before you begin Certain installations may require professional help Also be sure your installation conforms to local codes CAUTION PRODUCT IS FRAGILE TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE NOTE Pictures may not exactly define contour of china and components RECOMMENDED TOOLS AND MATERIALS Putty Knife Regular Screwdriver Closet Bolts Hacksaw REMOVE OLD TOILET Sealant Adjustable Wrench Wax Ring Gasket Flexible Supply Tube Carpenters Level Seat Tape Measure a Close toilet supply valve and flush tank completely Towel or sponge remaining water from tank and bowl b Disconnect and remove supply line NOTE f replacing valve first shut off main water supply c Remove old mounting hardware remove toilet and plug floor waste opening to prevent escaping sewer gases d Remove closet bolts from flange and clean away old wax putty etc from base area NOTE Mounting surface must be clean and level before new toilet is installed ROUGHING IN DIMENSIONS NOTE Distance from wall to closet flange centerline must be as listed below For 120012 Tanks Rough in distance is 305mm 12 INSTALL WAX SEAL Invert toilet on floor cushion to prevent damage and install wax ring evenly around waste flange ho
5. Loosely install retainer washers and nuts Side of washers marked THIS SIDE UP must face up RUBBER INSTALL TANK Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening Insert tank mounting bolts and rubber washers from inside tank through mounting holes and gasket and secure with metal washers and nuts With tank parallel to wall alternately tighten nuts until tank is snugged down evenly against bowl surface RUBBER GASKET A caution DO NOT OVERTIGHTEN NUTS MORE THAN REQUIRED FOR A SNUG FIT Install toilet seat in accordance with manufacturer s directions FLOW RATE TO RAISE ADJUSTMENT ADJUSTMENTS WATER a Flush tank and check that LEVEL yy tank fills and shuts off within TO LOWER ota 30 to 60 seconds and tank LEVEL water level is set as specified on tank rear wall b To adjust water level turn water level adjustment screw counterclockwise to raise level turn adjustment screw clockwise to lower level inlet c To adjust flow rate tank fill time turn flow rate adjustment screw clockwise to decrease flow rate increase fill time turn adjustment screw counterclockwise to increase flow rate decrease fill time d Carefully position tank cover on tank e The flush valve float has been factory set and does not require adjustments Repositioning of the float will change the
6. amount of water used which may effect the toilet s performance f If bowl fails to siphon an adjustment may be required with the lift chain Simply remove the chain from the retainment clip see Fig 10 and take up slack on the chain and reinsert on lift rod Make sure the chain is not too taught ASSEMBLY ASSEMBLY 7301311 100 Rev A USE FUTURE R F O SAVE TOILET CARE AND CLEANING When cleaning your toilet wash it with mild soapy water rinse thoroughly with clear water and dry with a soft cloth Avoid detergents disinfectants or cleaning products in aerosol cans NEVER use abrasive scouring powders or abrasive pads on your toilet seat Some bathroom chemicals and cosmetics may damage the seat s finish WARNING Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage ChinaLux shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing chlorine calcium hypochlorite TOILET SEAT CARE AND CLEANING When cleaning your toilet seat wash it with mild soapy water rinse the seat thoroughly with clear water and dry with a soft cloth Avoid detergents disinfectants or cleaning products in aerosol cans NEVER use abrasive scouring powders on your seat Some bathroom chemicals and cosmetics may damage the seat s finish After installation check the tightness
7. lding or plumbing contractor to insure local code compliance before installation This warranty shall be void if the product has been moved from its initial place of installation if it has been subjected to faulty maintenance abuse misuse accident or other damage if it was not installed in accordance with ChinaLux s instructions or if it has been modified in a manner inconsistent with the product as shipped by ChinaLux ChinaLux s option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation nor shall ChinaLux be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this warranty Some states or provinces do not allow the exclusion or limitation of implied warranties so this exclusion may not apply to you This warranty gives you specific legal rights You may have other statutory rights that vary from state to state or from province to province in which case this warranty does not affect such statutory rights For service under this warranty it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased or that a service request including a description of the product model and of the defect be sent to the following address AS America Inc P O Box 6820 Piscataway New Jersey 08855
8. rn with tapered end of ring facing toilet Apply a thin bead of sealant around base flange INSTALL TOILET Position toilet squarely to wall and with a rocking motion press bowl down fully on wax ring and flange Alternately tighten nuts until toilet is firmly seated on floor A CAUTION DO NOT OVERTIGHTEN NUTS OR BASE MAY BE DAMAGED Install caps on washers If necessary cut bolt height to size before installing caps Smooth off the bead of sealant around base Remove excess sealant tE INSTALL TOILET SEAT SE CONNECT WATER SUPPLY TANK WATER INLET Connect water supply line Wasi 2 between shutoff valve and tank water inlet fitting Tighten COUPLING NUT 1 4 turn beyond hand tight Check that refill tube is inserted into overflow tube FLEXIBLE COUPLING NUT SUPPLY 4 VALVE NUT N COMPRESSION Turn on supply valve and allow tank to fill until float rises to shutoff position CAUTION Overtightening of COUPLING NUT could result in breakage and potential flooding Check for leakage at fittings tighten or correct as needed Do not use plumber s putty to seal these fittings POSITION TOILET ON FLANGE a Unplug floor waste opening and install toilet on INSTALL CLOSET BOLTS Install closet bolts in flange channel turn 90 and slide into place 6 152 mm apart and parallel to wall O cap NUT 0 WASHER closet flange so bolts project through mounting holes